Home

375 Field Communicator

image

Contents

1. 3 00375 0004 0001 00375 0005 0002 00375 0005 0003 00375 0005 0004 00375 0006 0001 00375 0015 0002 00375 0031 0001 00375 0042 0002 00375 0042 0003 00375 0042 0004 00375 0043 0001 00375 0044 0001 00375 0045 0001 00375 0047 0001 00375 0049 0001 1 For use with AMS 375 Interface or 375 Easy Upgrade Programming Utility 2 Includes unlimited upgrades to System Card for 3 year period 3 Contains 375 Programming Utility and System Software DD database Page 7 3 5 Field Communicator 375 Field Communicator Ordering Information 375 Field Communicator 1 H HART F HART and FounpatION fieldbus HART Code Battery Type R Rechargeable NiMH Battery Pack 1 Power Supply Recharger 90 240 VAC 50 60Hz US UK EU connection types included 9 None 2 E English standard KL CENELEC ATEX FM CSA Intrinsically Safe includes FISCO as applicable NA No Approval Code Easy Upgrade 3 U Easy Upgrade Option includes unlimited upgrades to System Card for 3 year period 9 Not Included Code Options Spare Battery Pack B Spare Rechargeable NiMH Battery Pack 4 Expansion Module C Configuration Expansion Module 5 Typical Model Number 375 HR1EKLU 1 Base Model 375 includes Field Communicator Unit System Card Leadset with Connectors Carrying Case Getting Started Guide User s Manual 375 Resource CD Stylus and Straps 2 This option should only be considered if the user alrea
2. Anti glare coated Keypad m 25 keys including 4 action keys 12 alphanumeric keys 4 programmable function keys on off and 4 cursor control arrow keys membrane design with tactile feedback Page 5 3 5 Field Communicator Even the battery pack is approved for installation in hazardous areas The 375 Field Communicator is designed for use in areas where laptops shouldn t go m Rugged and Reliable It s called Field Communicator for a reason Some tasks just have to be performed at the device The 375 Field Communicator is designed for tough use in your plant or mill lts large keys and physical navigation buttons allow for one handed operation even with your work gloves on The rugged display is designed to take the knocks and shocks from normal use in the plant POWER SUPPLY SPECIFICATIONS Battery Pack m Rechargeable NiMH batteries Battery Operating Time Up to ten hours depending on usage Battery Charger Options Input voltage 85 240 VAC 50 60 Hz Cables included with U S European and U K plugs CONNECTION SPECIFICATIONS Battery Charger Mini DIN 4 pin jack HART and Fieldbus Three 4mm banana plugs one common to HART and FOUNDATION fieldbus IrDA Port IrDA Infrared Data Access port supporting up to 115 Kbps m 15 degrees recommended maximum angle from center line Approximately 12 30 cm recommended maximum distance As for reliable when was the last time you
3. Product Data Sheet D351019X012 00813 0100 4276 Bulletin 621 Communicator June 2003 375 Field Communicator mE Universal HART and FOUNDATION fieldbus m User upgradeable E ntrinsically safe mE Rugged and reliable E nterfaces with AMS www fieldcommunicator com eeeeee poore eee Ti eeeeeees ELLS 3 5 Field Communicator The 375 Field Communicator is designed to support all HART and all FOUNDATION fieldbus devices from all vendors Introduction The 375 Field Communicator is the new standard in handheld communicators Built on over ten years of experience with the 275 HART Communicator user requirements drove the features of this next generation communicator HART users worldwide told us how to make a better communicator Fieldbus users said they wanted a portable intrinsically safe communicator that supports all their fieldbus devices The result is the universal user upgradeable intrinsically safe rugged and reliable 375 Field Communicator EE reou EMERSON Process Management Product Data Sheet June 2003 3 5 Field Communicator A fold away stand provides the correct viewing angle on the bench and flips up to a locked position for secure hanging in the plant Product Description Building on the experience with the proven 275 HART Communicator the 375 Field Communicator includes enhancements designed to simplify your work in the field We desi
4. bus devices from more than 100 different vendors having a single field communicator that works with everything is a big help So grab the 375 Field Communicator and go Frets Product Data Sheet June 2003 i 375 Easy Upgrade Programming Utility File Edit Help 375 to PC Database Comparison Results Your 3 5 is out of date in the following ways 40D Upgrade 375 Detect 375 Disconnect Check for Updates Click here to check if updates are available on the Internet e 3 5 Field Communicator Event Capture Files Sys Software fi 1 HART App fi 0 FF App a2 HART Enabled FF Enabled E asy Upgrade Memon Usage System Card E Free Space Fosh MT 122v Traneter 4ll ancel Easy Upgrade allows communication between the 375 Field Communicator and a PC using IrDA The IrDA port enables transfer of configuration data between the 375 and AMS as well as upgrading of new Device Descriptions and functionality m User upgradeable New HART and FOUNDATION fieldbus devices as well as functional updates to existing devices are introduced continually by device vendors Keeping up to date with the required Device Description drivers for all the devices in your plant can be a real challenge Now with the Easy Upgrade option keeping your communicator updated with the most current Device Descriptions DD s is easy Page 4 As new HART and FOUNDATION fieldbus DD s become ava
5. dy has a 375 Power Supply Charger Note Only 375 with the 375 Battery Pack Power Supply Chargers may be used 3 The Easy Upgrade capability allows the user to add new System Application software and Device Descriptions DD s to the 375 To upgrade without this feature the System Card must be sent a Service Center 4 A fully charged battery pack is capable of delivering power for 8 hours of typical field use If requirements exceed this specification a second battery pack is recommended 5 The 375 is capable of storing a total of 25 configurations For increased storage capacity use the Configuration Expansion Module which is capable of storing in excess of 500 configurations Emerson Process Management Asset Optimization Division 12001 Technology Drive Eden Prairie MN 55344 USA T 1 512 832 3235 F 1 952 828 3033 www fieldcommunicator com 2003 Emerson Process Management The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are available on request We reserve the right to modify or improve the designs or specifications of our products at any time without notice All rights reserved AMS is a mark of one of
6. figuration data via the infrared port on the 375 Field Communicator and AMS on your PC Carry your 375 Field Communicator out to the field to configure or update one or many devices Save device configurations in your 375 Field Communicator for safe storage or transfer to AMS The optional FIELD COMMUNICATOR Configuration Expansion Module stores hundreds of device configurations safely in your 375 Field Communicator The Configuration Expansion Module safely stores hundreds of device configurations Together the 375 Field Communicator and AMS enable you to more efficiently manage all of your devices the assets that are the foundation of your process Product Data Sheet June 2003 3 5 Field Communicator 375 Field Communicator Spare Parts List Ruggedized 250 Ohm Load Resistor 00275 0096 0001 Rechargeable NiMH Battery Pack with Accessory Case 00375 0002 001 1 Power Supply Charger 90 240 VAC 50 60Hz US UK EU connection types included 00375 0003 0011 Lead Set with connectors Mounting Straps Carrying Case with straps Accessory Case clips to Carrying Case Stylus pack of 5 IRDA to USB Adapter 1 Expansion Port Plug System Card HART and FOUNDATION fieldbus System Card HART with Easy Upgrade Option 2 System Card HART and FOUNDATION fieldbus with Easy Upgrade Option 2 Configuration Expansion Module Stand and Utility Plate Getting Started Guide User s Manual Resource CD
7. gned the 375 Field Communicator user interface around the 275 leveraging the navigation features users told us they liked Then we added powerful features including a much larger touch screen HART Revision 6 support and the ability to upgrade your 375 Field Communicator onsite using the Internet Page 2 m See the difference The 375 Field Communicator runs on Windows CE a robust real time operating system The display is 70 larger than that of the 275 HART Communicator and uses transflective technology making it easy to read in both bright sunlight and in normal lighting To make sure we covered all conditions we added a multi level backlight allowing the display to be viewed in those areas of your plant with dim light The touch sensitive display and large physical navigation buttons provide for efficient use both on the bench and in the field We made sure that the weight was evenly distributed for comfortable one handed operation in the field E It is loaded The 375 Field Communicator has a processor that is 20 times faster than the 275 It features 32MB of application memory 64 times more than the 275 HART Communicator The Configuration Expansion Module holds hundreds of device configurations and it is externally accessible Enhancements in the battery pack allow a full recharge in 2 hours 8 times faster than the 275 HART Communicator m Easy Upgrade keeps your communicator current If that s n
8. had to send your 275 HART Communicator in for repair That s exactly the kind of reliability we ve built into the 375 The 375 Field Communicator is designed manufactured and tested to specifications that are even more demanding The 375 Field Communicator is designed to go wherever you have to go to get the job done ENVIRONMENTAL SPECIFICATIONS Usage m 10 C 14 F to 50 C 122 F 0 to 95 RH non condensing for 0 C 32 F to 450 C 122 F Charge m 0 C 32 F to 40 C 104 F Storage m 20 C 4 F to 55 C 131 F with batteries Storage Without Batteries m 20 C 4 F to 60 C 140 F Enclosure Rating m P51 from front Shock Tested to survive a 1 meter drop test onto concrete EASY UPGRADE REQUIREMENTS Usage PC with internet access CD Rom drive IrDA port or adapter Windows 2000 or XP Product Data Sheet June 2003 AMS m Interfaces with AMS The 375 Field Communicator is fully compatible with AMS the industry standard for asset management software In fact Control Magazine readers selected AMS as the 1 Calibration Software package for 3 years in a row Page 6 3 5 Field Communicator AMS allows you to configure streamline calibration document and troubleshoot HART and FOUNDATION fieldbus devices AMS uses the intelligence from field devices to create a predictive maintenance environment Transfer device con
9. ilable download them from the Internet and upgrade your 375 Field Communicator In addition as functional enhancements to the 375 HART and FOUNDATION fieldbus applications become available download software updates from the Internet and upgrade your 375 Field Communicator No longer is it necessary to send your communicator to a service center to have new DD s or software updates added No longer is it necessary to be without your communicator while you wait for upgrades Easy Upgrade lets you update your own 375 Field Communicator On your site within your control when it s convenient for you Product Data Sheet June 2003 m Intrinsically Safe The 375 Field Communicator meets the Intrinsic Safety requirements of the listed regulatory agencies and standards All of the available Hazardous Locations approvals are provided in a single model option see Ordering Information CENELEC ATEX Factory Mutual FM Canadian Standards Association CSA FISCO x APPROVED Specifications PROCESSOR AND MEMORY SPECIFICATIONS Microprocessor 80 MHz Hitachi SH3 Memory Internal Flash 32 MB System Card 128 MB or higher secure digital card RAM m 32 MB Expansion Module m 32 MB or higher secure digital card PHYSICAL SPECIFICATIONS Weight Approximately 2 Ib 0 9kg with battery Display m 1 4 VGA 240 by 320 pixels monochrome 3 8 9 6 cm transflective display with touch screen
10. ot enough to get your attention the 375 Field Communicator is also user upgradeable via the Internet This means it is no longer necessary to send your communicator anywhere to have new device drivers added Product Data Sheet June 2003 3 5 Field Communicator A lt gt Jy ijz Flale Designed not only for use on the bench the 375 Field Communicator enables you to do those tasks that just have to be done in the field m Universal HART and FOUNDATION fieldbus The 375 Field Communicator is designed to support all HART and FOUNDATION fieldbus devices If you are familiar with the 275 HART Communicator used in thousands of plants worldwide for more than ten years you will appreciate universal HART support in a single intrinsically safe handheld communicator The 375 Field Communicator can also be used to configure all the FOUNDATION fieldbus devices Page 3 in your plant Use it to perform diagnostics for effective start up and troubleshooting of FOUNDATION fieldbus segments Create a quality segment by diagnosing the network DC voltage and average noise Detect power supply problems by monitoring low frequency noise on a segment Locate incorrect terminations and faulty devices by diagnosing the communications signal level No longer do you need to drag a laptop computer out into the plant to communicate with your FOUNDATION fieldbus devices With over 600 different HART and FOUNDATION field
11. the Emerson Process Management group of companies The Emerson logo is a trademark and service mark of Emerson Electric Company All other marks are the property of their respective owners EMERSON Process Management

Download Pdf Manuals

image

Related Search

Related Contents

Craftsman 316.792520 Operator`s manual  ペルクール(SP  Page 1 Page 2 Page 3 2009年 クボタトラクタ 誕生50年記念 感謝の  LSI 40919H Network Card User Manual  PKA Series - orientalmotor.cz  4400 Mobile Handset User Guide  LC-Power 604B computer case  The Audit Plan – template user guide  平成24年度独立行政法人国民生活センター業務実績報告書①  Semaine du Lundi 26 au dimanche 1 novembre 2015  

Copyright © All rights reserved.