SUPERVISORY SYSTEM
Contents
1. Electrosys ilelco SUPERVISORY SYSTEM USER MANUAL SUPERVISORY SYSTEM USER MANUAL v10 22 Electrosys ilelco _ 1 1 Hardware Requirements 1 2 Software Installation and Configuration 1 3 Password 1 4 Configuration File SISSUP32 INI oO 0 0 1 5 Network Window 1 6 Toolbar and Status bar 1 6 1 Phone remote mode 1 6 2 Serial local mode 1 7 Menu Bar 1 7 1 Supervisor End 1 7 2 Options 1 7 3 Reports 10 1 7 4 Value Reports 11 1 7 5 Alarm Report 13 dq Oo dq O O N SUPERVISORY SYSTEM USER MANUAL v 1 0 2 22 Electrosys cid y 1 7 6 Printing a saved report 1 8 Inside station 1 9 Stations Tool Bar 1 10 Station s Menu 1 10 1 Supervisor End 1 10 2 Station 1 10 3 Options 1 11 Reports 1 12 Alarm Window DATABASE 1 13 Names conventions 1 13 1 Fixed Tables 1 13 2 Network dependent tables APPENDIX A CONNECTIONS AND WIRING 1 14 Local modality 1 15 Remote modality APPENDIX B MODEM SETUP 1 16 Standard Modem 1 17 GSM Modem 1 18 Radio Modem SUPERVISORY SYSTEM USER MANUAL v10 14 14 17 17 17 17 17 19 19 20 20 21 24 26 26 26 27 27 27 28 gt gt Electrosys gt ilelco OVERVIEW Continued technological advancement has brought about an increase in the complexity of the various broadcast systems However sufficient advancement in instruments for control and supervision have not been developed
2. seconds then the window disappears and the Supervisor starts You can stop the sequence by pressing the Cancel button at any time RADIO MODEM To operate your radio modem you must set up the proper modality from a terminal emulation software before you connect the modem to the Supervisory System Radio modem don t need setup when the supervisory System starts so you must only put Radio on the right line of the SISSUP32 INI file SUPERVISORY SYSTEM USER MANUAL v1 0 28
3. Stores all the alarm codes and descriptions for every logic You don t need to modify this table SUPERVISORY SYSTEM USER MANUAL v1 0 21 22 Electrosys ilelco Alarm Code The code is unique for any alarms of an element type See Annexes In addition there are code 100 for No RS232 answer 101 for Drop Line 102 for Station don t answer in case of a polling error Alarm Type C Communication D Digital A Analog measures Alarm Position Position of alarm in the logic Element Type Type of element Alarm description gt Building The Building table stores all the parameters needed to define the building window if any This window is present only if you have more than one logic on the same station as in station 3 otationID Number of the station Buttonld Number of the button on the building window X Position of the button pixels Y Position of the button pixels Xwidth X Width of the button pixels Ywidth Y Width of the button pixels Name of the picture displayed on the button Not Used for no picture Port number tied to the button Module number tied to the button ToolTip Tooltip displayed when the mouse passes over the button Elements Config This table lists all parameters of every logic Element Type Logic or module type By ex G032TXM or GO32MOD ADC Bit ADC bit number ADC Offset 0 for Unipolar ADCResolution 2 for bipolar center zero ADC Power Max Factor 1 if
4. be disabled The ESS stores all information acquired from the stations in a database The database is accessible at any time for reading and printing with or without a hard line connection This database also stores all configuration information such as telephone number to call messages and colors used for labels and errors The user SUPERVISORY SYSTEM USER MANUAL v 1 0 4 2 Electrosys ilelco can modify the configuration information in order to personalize the ESS The database engine used is Microsoft Access 97 DAO 3 51 The Supervisory System has different password levels to ensure system security INSTALLATION 1 1 1 2 HARDWARE REQUIREMENTS PC needs Personal Computer with Pentium Il 233MHz CPU or better Video Graphic Color 16 bits 65535 or higher Video Screen Area 1024x768 pixels or higher OS Microsoft Windows 98SE ME NT 2000 XP CD drive Installation CD rom for the Electrosys Supervisory System DIGICOM modem GSM modem or radio link for remote mode only VVVVV WV SOFTWARE INSTALLATION AND CONFIGURATION From CD ROM to properly install the ESS on your PC insert CD ROM and run SETUP EXE from its root folder After the installation is complete you can start the ESS from the Start menu gt Programs gt Electrosys Supervisory System gt Electrosys Supervisory System Note If the setup procedure remarks a library version conflict like A file being copied
5. is not newer than the file currently on your system you have to keep the existing version by clicking YES If the setup procedure asks for a system restart you have to accept and after the system reboot you have to repeat the setup procedure manually by running SETUP EXE from the ESS CD ROM root folder The default name for the stations are Station where stands for a number and the telephone number is left to ATD After installation the user can change the configuration of the software to meet his needs if these differ from the default settings see Database section You must configure the logic in the station for spontaneous calling so it will call the PC when a fault occurs For the spontaneous calling configuration you must connect the PC to the transmitter logic in local or remote mode and choose from the Options menu Set Spontaneous Call The Supervisory System will then show a window for configuring spontaneous calling see related section SUPERVISORY SYSTEM USER MANUAL v 1 0 5 1 4 22 Electrosys ilelco PASSWORD The ESS has 3 password levels Level 0 1 and 2 Level 0 disables all RS232 communication local transmitter control only Level 1 disables all remote control ESS can only receive data from the transmitter logic Level 2 is the full interactive level where the ESS is able to send and receive data having complete control of the logic If a command is issued with a p
6. max power to FS 5 4 MaxP 4V with 5V FS 10 9 MaxP 9V with 10V FS DAC Bit DAC bit number Network Table Network description This is a list of all stations in the network with their telephone number and position of station label in the Network window SUPERVISORY SYSTEM USER MANUAL v1 0 22 Warning 2 Electrosys gt eco Station ID Station number Station Name Station name It is what will be displayed in station label in Network window Y Label Position y left position of label X Label Position X top position of label Complete Hayes command to call the station ATDT or ATDP for tone or pulse dial followed by phone number Commas can be used for pause between numbers Complete station name Ignored by Supervisor Time between polling If both Polling fields empty or zero means no polling Time between polling If both Polling fields empty or zero means no polling Note If you change the station name you must also change the name of the two tables of the database linked to the station the Station Name table and the Station Name Alarm History table Station Elements Table Station description Here is description of all elements in the station Station ID Station Number Port ID Transmitter Number Path Sequence of the ports if there is more than one multiplexer Element Type Name of element as listed in Element Config table Module ID Module nu
7. 1HHAI Analog input parameters Fields description Relevant change Variation over which store value in historic in Units If is a power not a linear input Significant change Set the number of digits to display 1 integer 0 1 one decimal digit and so on gt G021AO Not Used gt G021DI The stands for the station ID and the port number E g for the logic on station 1 and port 3 103 StationID 100 PortNumber This method allows you to configure every single logic E g you may have two logics with two different powers SUPERVISORY SYSTEM USER MANUAL v1 0 24 2 Electrosys ilelco Digital input description table Var ID Off State On State Relevance Color Off Back Background color if bit is O Color Off Fore Foreground color if bit is O Color On Back Background color if bit is 1 Color On Fore Foreground color if bit is 1 Visibility Off State Yes if Off State label is to be displayed Visibility On State Yes if On State label is to be displayed Create Alarm If the Off State has to create an alarm gt GO21DO Digital output description table Visibility On State gt G021 FTH Linked with the Al table by Var ID field this table stores the thresholds and alarm for analog inputs Value over which there is an alarm condition Multimeter Top Top limit of multimeter Create Alarm If Yes Al over Maxim or under Minim creates an alarm Note The multimeter color is RED between B
8. ER MANUAL v1 0 20 1 13 1 13 1 22 Electrosys ilelco NAMES CONVENTIONS There are two main types of tables in the database the first one is present for every logic type and station configuration and it have a fixed name the second one is network dependent and the name is network dependent too The fixed tables are Alarm Table Building Element Config Network Table Station Only if you have not changed the name of the station Station Alarm History Only if you have not changed the name of the station Station Elements Config VVVVVV V The name of other tables depends on the configuration of the network that you want to control The general structure is shown below each rectangle represents one character Elements with modules Logic type Logic Numb Table Type Elements without modules Logic Type Table type The logic type is the identifier of the logic the same that appears in the table Element Config Then only for TXM transmitter tables that ends with letters Al or TH there is the logic number Station ID Logic port number see 1 13 2 note 1 At the end of the name there are two letters TH thresholds used for the multimeter zones Al Analog input AO Analog output never used DI Digital input DO Digital Output only for DAB exciter there is one more table with the extension MISC FIXED TABLES Alarm Table The Alarm Table
9. assword of too low a level and therefore not valid the ESS will ask you the right password level and the command is discarded Default passwords are 00000000 11111111 and 22222222 for Level 0 1 and 2 respectively Level 1 is the default Password modification will be discussed later CONFIGURATION FiLE SISSUP32 INI The file SISSUP32 INI is copied in the supervisor directory at installation time You can modify this file with an ASCII editor such Notepad The default configuration is listed below Default Setting Description Comm Settings for the RS232 Modem 2 CommPort RS232 Res Net jpg Network Window Image Standara Modem Type Gsm Radio or Standard 0000 PIN Number for GSM modem ATEVB1F0M111 D06K01N1 C0YX350 286W0530 3 MS 9 0 9600 9600 Modem init string 3 Communication timeout secs Network Caption of Network Window o Alarm Downloading 5 Delta Polling s Yes Save at Polling Line 1fixes the settings for the serial port The Supervisory System uses 9600 baud no parity 8 message bits 1 stop bit Line 2 identifies the serial port only comm ports 1 4 are recognized Line 3 sets the name and path for the image of the Network form Line 4 sets the modem type For both Standard and Gsm modems the line 6 is the init string For the radio modem the string is ignored Line 5 Pin number for GSM Modem used only if requested Line 6 is the modem initialization str
10. ct the call and give an alarm The station label will then blink red The blinking red station label will continue to blink until the ESS is commanded to call the station When polling made if polling is enabled an icon appears near the polled station gt If station doesn t answer an alarm occurs SUPERVISORY SYSTEM USER MANUAL v10 T 2 Electrosys ilelco 1 6 TOOLBAR AND STATUS BAR The Toolbar the Status bar and the Menu bar are always visible E ea 6 831 c n E LIL 181 Supe Prnt Screen a 1603 2000 17 23 240 Tools in Toolbar are Phone for remote mode and Serial for local mode you can drag them onto the label of the station you want to call Alarm Switch To Enable Disable the alarm downloading Save Button enabled only when connected is used to store the current station s situation all values of all ports Report icon drag the icon onto the station you wish to see the history of in the database The Print Screen button makes a hardcopy of the actual screen The last panel displays the date and hour information VV VV WV Status bar is the little bar in the bottom of the screen The left section is used for messages All messages appear here Abnormal condition are red information are black Error are underlined with a beep to force the eye to look here The central section is used as progress bar The right section is used only when connect
11. cted station The second choice deletes the historic table of the connected station To improve performance it is useful to delete periodically historic and alarm tables in the database Together with cleaning table is useful periodically to COMPACT database use Microsoft ACCESS 97 to make it SUPERVISORY SYSTEM USER MANUAL v 1 0 17 Electrosys itelco _ Spontaneous Call Section You can set the transmitter logic to automatically call Supervisor if a critical alarm occurs Choosing the Options menu after station connection does automatic call setting 4 Spontaneous call settings Station will answer as Station Number 5 Curent Stored Station Number 1 Iw Spontaneous Call Enabled Station will use this number E12 Use comma Far pause between and number Send Settings to the Station Cancel When this window is open it displays the actual settings of the logic Here the station number is displayed Station will answer as Station Number The Supervisor in case of station spontaneous call to determine which station is calling uses this number Commas may be inserted in the telephone number to pause between different number sections The Cancel button allows you to close the window without changes SUPERVISORY SYSTEM USER MANUAL v1 0 18 1 12 Electrosys ilelco REPORTS By clicking on the Reports icon in the toolbar you can see the historic an
12. d alarm reports for the connected station ALARM WINDOW The alarm window is where the alarms are displayed on the fly If the station is connected you will see all alarms of the transmitter logic only with Alarm Downloading feature enabled In addition to the logic alarm there are The Drop Line Alarm if line drops during a call The No RS232 answer Alarm if the transmitter logic does not answer the Supervisor RS232 communication When an alarm occurs the Alarm Window opens itself if minimized and opens up on top of all other windows also if other applications are running together Hit F8 key to clear alarms from this window Note this operation does not clear the relative records from the history database 15 03 2005 18 08 33 Station Station 08 Pork 1 Mod 0 Type ADT Vision Alarm TERMINATES 15 03 2005 18 07 57 Station Station 08 Fort 1 Mod 0 01 Vision Alarm 443 SUPERVISORY SYSTEM USER MANUAL v1 0 19 gt gt Electrosys gt ilelco DATABASE The Database is where all the information needed by the ESS is stored such as stations names and configurations historic tables logic parameters and so on O Incorrect data in the Database may cause the ESS to not work properly or to crash Warning You can modify every table but be extremely careful The Database default file is SISSUP32 MDB You can see or modify it with Microsoft Access 97 Or Electrosys DB Browser a special
13. e prompted for your current password and then asked to enter your new password Insert Password for Level 2 You can select the level of the password Sissi E you want to change However you can only change the password of a level lower than yours Remember that you have entered the password first You will be Cancel asked to enter the new password two Mo times to avoid errors Current Level is 1 Only asterisks will appear for each character as you type in your password REPORTS In the Stand by mode you can access the Report menu by dragging the Report icon onto the station you wish a report on In the Connected mode you can access the Report menu by clicking on the Report icon The report menu will look like the one that follows SUPERVISORY SYSTEM USER MANUAL v1 0 10 gt Electrosys lelco EF Reports 1 Station 05 042 Tes Control Unit Port 1 T Analog Input e Digital Input e Digital Output o v A Port 1 Alarms Part 1 Modules Report m H P A Module 1 Module 2 Module 3 He H P Module 4 s 3034 Acquisition Logic Port 2 M A Station Alarms E From here by double clicking the items with the red arrow you can access the reports There are two different types of reports The first one is the Values Report of Analog Digital Inputs and Digital Outputs of the log
14. e set up for the modality that you want point to point or multipoint SUPERVISORY SYSTEM USER MANUAL v 1 0 26 22 Electrosys ilelco APPENDIX B MODEM SETUP 1 16 1 17 Standard Modem The standard Electrosys modem is DIGICOM For proper connection you must set your SISSUP32 INI file for Standard modem type and you must provide the init string that follows ATEVB1FOM1L18D08K01N1 C1YX3S0 281W0530 3 MS 9 0 9600 9600 For a standard Robotics modem the init string must be ATEOVOX3F1L2M18D28H08108R18S508A08K08M0O8N6SO 28W0 For the Lucent modem 56K ATEVB1FOM1L18D08K01INOQOS37 98W0 Standard AGERE Modem string ATEVB1M1L1N18D08K08G0N1 COYX3S0 2s6 657 60s95 28Q08W0S30 3 MS V32 0 9600 9600 How to set AT commands for ESS modem init string REO No Echo VQ Numeric Result Codes B1 Standard modulation Bell M1 Speaker on durimg call establishment but off when receiving carrier Ev L1 Low Speaker volume amp DO Modem ignores DTR amp KO No flow control Ae Disable error correction mode 900 No data compression X Busy detection reporting is enabled 509 2 Answer after 2 ring 83023 Inactivity time online MS V32 0 9600 9600 Modulation selection V32 at 9600 bps and no automode The modem must be powered before you start the Supervisory System GSM MODEM GSM modem needs specific initialization when powered on This initialization is au
15. ed The panel on the left is used for the port currently displayed on video the right panel for the background polling of other ports For any connected port there is a led the color of the leds can be green for communication OK red for communication error gray for no port answer black for no multiplexer answer darkgray while waiting an answer from the port yellow while checking the port for hardware type SUPERVISORY SYSTEM USER MANUAL v 1 0 8 1 6 1 1 6 2 1 7 1 7 1 1 7 2 22 Electrosys ilelco PHONE REMOTE MODE To call a station in remote mode drag the Pije xj phone icon into the station label The communication window will then be displayed Last Message Connect 9600 40 x The connection window shows the station name you are calling connection mode local or remote last modem error and the time f Station 05 Connected The Supervisory System will try to connect up three times The Cancel button will terminate the call SERIAL LOCAL MODE As above but used for a local RS232 connection MENU BAR SUPERVISOR END End will terminate the Supervisory System program Is possible to stop the ESS only if not connected OPTIONS The Options menu contains 4 sections the first deals 4 yam on any alarm with the alarm window the second with deleting the Alarm Downloading databases the third with passwords and the fourth with sp
16. ic and the second one is the Alarm Report 1 7 4 VALUE REPORTS The Value report shows all the database entries of the selected station from Start Date to Stop Date The default Stop Date will be the current date the Start one day before Al Report of Station 05 Port 1 Module 0 G042D m S Esas 8 a Previews Piin Start dale Stop date 15 03 2005 Ambient Temp C ETRE The report period can be manipulated by setting Start Stop Date SUPERVISORY SYSTEM USER MANUAL v1 0 11 Electrosys Ilelco A complete set of data analog and digital is stored in the database whenever a connection occurs or the transmitter logic detects a change in a parameter that meets the criteria in Relevance or Relevant Change field of the database A digital input variation will cause a record to be stored if the respective Relevance field contains Yes Analog variations will cause a record to be stored if the Relevant Change field is exceeded In this way the operator can set the thresholds at which a record will be stored See section DATABASE for a description of the database fields PON MENN choose among printing the report to Disk File Mame printer Print printing Se HD E report to screen Print Directories alarm ptr uem xls Text or Excel format Sissup32 dll Save to file In last DBBrow
17. in parallel The Electrosys Supervisory System ESS has been developed to provide all the Supervision and Control requirements for the new Broadcast Systems while guaranteeing ease of use thanks to an advanced user interface This user interface is instrumental in helping the technicians detect hardware failures The Electrosys Supervisory System is designed to control one or more transmitters in one or more broadcasting stations The stations can be located anywhere there is two way communication The ESS can operate in two modes Local mode in which the PC is connected to the Logic with a serial cable see Appendix A This mode is very useful when using a portable personal computer PC Remote mode where the PC located at a remote site is connected via a standard modem a cellular modem or a radio link to the station s see Appendix A The standard Electrosys modem is DIGICOM used for the telephone connection at a speed of 9600 baud Any station s logic connected to the ESS has the ability to call the system PC should an RF Alarm occur within its associated transmitter The ESS PC is not continuously connected to the station logic but in a standby condition awaiting a station logic to contact it When this happens the ESS PC downloads the transmitter s complete status so the system operator can determine the cause of the problem ESS can also ask station state by polling with different time for any station Polling can
18. ing Line sets the communication timeout Line 8 sets the caption for the Network window Line 9 allows automatic alarm downloading when the connection is established Line 10 Is the minimum time between two polling calls Line 11 forces the supervisor to store the station status at every interrogation If you set this parameter to Yes and your polling time is short the Historic Database may become very large At the end of the SISSUP32 INI file are listed some initizalization strings for various modem s types Standard and GSM SUPERVISORY SYSTEM USER MANUAL v10 6 a put gt E a in gt Electrosys rileico ESS OPERATIONS 1 5 NETWORK WINDOW Electrosys Supervisory System El 52133 2 e a3 Ea E sd KO T KI A 1 xd Supervisor Options Help The Network window is the stand by position of the Supervisory System and it displays the Network situation The window shows all stations connected to the Electrosys Supervisory System using a label with the station name After initialization when hourglass cursor disappears the ESS goes into the stand by mode Stations are not connected but the network is active and waiting for a station to call If an alarm occurs and the spontaneous call on that station is enabled the station will call the ESS this icon appears next to the station Ff The ESS will download and save the actual state of the station in its resident database disconne
19. mber in specified Transmitter Polling Percentile of interrogation of any logic Only for Module O and Port gt 0 Station sum MUST be 100 Other info Used to select the configuration for GO11 logic if the station has an N 1 system gt Station ZZ Historic table for the station where stands for the Station ID and the port number Here are stored values from logic if a relevant variation occur If you change the name of the station you must change the name of this table also gt Station Alarm History SUPERVISORY SYSTEM USER MANUAL v1 0 23 22 Electrosys eco Alarm historic table Stores all station and communication alarms for the station where stands for the Station ID and the port number If you change the name of the station you must change the name of this table also Alarm ID Alarm unique identifier Time Stop When the alarm ended C Communication D Digital A Analog measures Alarm Code Pointer to Alarm Table table for description Alarm Value Value of analog measures that caused the alarm Alarm Position Position of alarm in the logic Units for Alarm Value 1 13 2 Network dependent tables All the tables that are not listed in the previous section are network dependents e they may be present or not and they may have names that slightly varies depending of your network configuration By example for the GO21 logic there are the following tables gt GO02
20. n E onto the measure If an analog input alarm occurs a red mask on the label blinks When you connect to the station and you have more than one port the first window displayed is the Building this window summarizes the status of the station in a graphical way and it shows a flashing red label for logics that have open alarms if alarms downloading is enabled It also has buttons that allows you to switch between the windows in a simple and quick way From the program s forms you can control and set all parameters of the units With command buttons on each form you can send commands to the transmitter from the remote site SUPERVISORY SYSTEM USER MANUAL v1 0 14 Electrosys gt telco TYPICAL TX STATION The main form for the G042 logic follows Im ELS System E Elsa 1 31 03 CR 3 1 ESSET t all 3 Alam Downloading Save Situation Repote Pink Screen e 15 03 2005 17 55 10 1 Status Nominal 2 MM a RF Alam General 042 Control Cogie Unit SUPERVISORY SYSTEM USER MANUAL v 1 0 15 gt Electrosys lelco The module number button brings up the H P A windows Each H P A has three views Physical Circuit and Status here you can see the Status AAA 48 273 AAA le m Downloading 4 Siret Sibuahion iE Print Sonar e 15 03 2005 17 55 57 Tem
21. ontaneous calls In the Stand by mode only the first and third sections are available Password Level Password Change Delete Historic Database Delete Alarms Database Alarm Window Section Set Spontaneous Call By selecting the option Warn on any alarm you can show or hide the alarm window The presence of check mark Y means the alarm window is activated By selecting the option Alarm downloading you can choose to download all logic alarms the same functionality is available via the switch on the toolbar If not selected no alarm will be downloaded The presence of check mark y means that downloading is activated Default is to not download and you can change this default in the SISSUP32 INI SUPERVISORY SYSTEM USER MANUAL v10 9 gt Electrosys 1 7 3 gt 2100 Password Section This section has two choices Password Level and Password Change The Supervisory System has 3 different xj password levels Level 0 Level 1 and Level 2 At Level 0 RS232 communication is disabled At level 1 you are able to see all the logic status but you can not issue commands to control it At Level 2 you have complete control of all the transmitter functions Current Level is 1 Master 2 0 Mot Connected By choosing the Password Level menu you can change your access level To modify a password choose the xj Password Change menu You will b
22. ottom and Minim YELLOW between Minim and Low GREEN between Low and High YELLOW between High and Maxim RED between Maxim and Top Between Low and High value is OK SUPERVISORY SYSTEM USER MANUAL v 1 0 25 gt n 22 Electrosys ilelco APPENDIX A CONNECTIONS AND WIRING 1 14 LOCAL MODALITY In local modality PC can be directly connected to the logic on RS232 J18 connector If you have a G232 multiplexer you must connect the cable into the master port Use a serial cross RS232 cable null modem with this pinout shield cable is preferred 9 pin PC Side 9 pin RS232 Logic Side REMOTE MODALITY For the remote modality you can choose between standard modem GSM Modem or Radio Link Standard Modem Connect the DIGICOM modem provided by Electrosys with the serial port of the PC Use a standard serial cable with this pinout Modem 1 2 3 5 6 7 8 12 120122 5 3 2 8 6 5 1 NC 4 9 To optionally share modem and phone use a T phone line splitter To connect modem to telephone line use a standard phone cable GSM Modem Connect the serial port of the PC with the 9 pin connector on the GSM Modem using a flat cable Place your antenna and test the signal quality with the Gsm Modem Setup software provided by Electrosys Radio Link Connect the TRIAD Radio Modem provided by Electrosys to the serial port of the PC You must use a flat cable The Radio modem must b
23. perature Sena Y Amplis HPA Gee Pnyslcall Top View SUPERVISORY SYSTEM USER MANUAL v1 0 16 22 Electrosys gt 1 9 STATION S TOOL BAR After connection the phone and local connection icons disappear from the toolbar and a new one replaces them the Multimeter Dragging and dropping it on any analog measure an analog Multimeter can be displayed with colored thresholds nere x n 2400 60 1440 192 240 1200 1650 21 Vision 2008 W A new tool is active only with connection present Save Clicking on it you cause an immediate complete storage of all values in the database 1 10 STATION S MENU 1 10 1 SUPERVISOR END You cannot terminate ESS if you are connected to the station If you wish to terminate the ESS you must first terminate the station connection 1 10 2 STATION Close Communication Closes station connection local or remote gt SaveSituation Print Screen Station Report This commands are the same that you can find on the toolbar 1 10 3 OPTIONS Options is the same as seen before Here you can use all four sections See 81 7 2 for sections 1 and 3 gt Historic Delete Section This section has two choices Delete Alarm Historic and Delete Value Historic Through the first choice you may delete the alarm table of the conne
24. software provided by Electrosys that allow the addnew update and delete of the database table records but not the updating of the database structure ESS uses the database to manage input output configuration of any connected logic That information are static you can insert or modify it before ESS starts ESS uses the database also to store System dynamical evolution It makes that storing alarms in Station Alarm History table and values in Station table is a two digits number See 1 13 for explanation Values are graphical representations of all analog and digital values read by ESS at a single time Criteria of storing value records in database is to store a complete set of measurements analog and digital when a measure variation occurs If a Digital Input or Output variation occurs a new record is added only if the Relevance see later field of the Digital Input varied is Yes otherwise no record is added in database For Analog Input or Output you can set the minimum variation of the measure that cause storing a new record in historic database field name is Relevant Change see later The following is the description of the basics tables of the database The tables names and numbers may be different depending on your logic type s and station configuration The fields with the name on a gray background don t need to be modified by user Be careful changing this fields SUPERVISORY SYSTEM US
25. szer amp exe preview and Sao Password ini your report to a file in SISSupse exe Sissupa2 hip iC case you have to input report name If you choose the Print Preview option the preview window appears After the report is printed to screen you can print it to printer or Page 1 1 p Print AT of Station 05 port 1 mod O from 14 03 2005 to 15 03 2005 DD MM YY Description 6042 Electrosys 15 03 2005 17 40 21 15 03 2005 17 28 46 15 03 2005 13 03 50 i i Vision 2000 Vision W 1921 exit by choosing the Sound 1 W 101 Sound 1 W 106 Sound 2 W 20 Sound 2 W 21 buttons In the bottom of Reflected W Reflected Wo Ambient Temp c 35 Ambient Temp 29 the window With arrows buttons you can change report page Pag 1 Global Report of Modules This kind of report is available only if you have a logic with H P A modules You can access this report by the Port modules report item on the menu tree the report lists all analog data of the modules connected to the port in a table that allows you to easily compare currents powers etc of modules If more that one record is stored for each module the most recent is used SUPERVISORY SYSTEM USER MANUAL v1 0 12 Electrosys gt eco 1 7 5 ALARM REPORT afajaaja ac 292011218 3 181 The Alarm Report shows all stored alarms The most recent Alarms appears at the top of the list Field Definitions Time S
26. tart When alarm occurs Time Stop When alarm ends Type C communication alarms D Digital Input alarm see annex A Analog Input alarm see annex G General alarm see annex Element connected to specified Port Module Alarm description Value Analog value that caused alarm only for Analog alarms Units of Value A Print menu is at the top of the Window The Print Print Preview and Print To File menus allow you to print a report to the screen to the Printer or to a file Prnt Ta File E vit SUPERVISORY SYSTEM USER MANUAL v1 0 13 1 7 6 1 8 22 Electrosys telco PRINTING A SAVED REPORT You can read and print the saved reports in two different ways gt Text format If you use a common Windows editor ex Notepad exe or Wordpad exe to print a report saved to file in text format you can see all the report and print it correctly using the settings font Courier New 8pt gt MS Excel format Opening the alarm report file with Microsoft Excel you can see the report modify it and print it like you prefer INSIDE STATION The appearance of the station windows is tied to the station elements Each logic has it s own window and you can switch between them via the building window if any or by the modules buttons After connection the main panel of the station is displayed on the screen All analog data on the window can be viewed in the Multimeter dragging and dropping the ico
27. tomatically provided by the Supervisory System When you put the Gsm modem type in the SISSUP32 INI file you must also put the init string in the proper line Each command of the init string must be followed by a minus sign When the Supervisory System starts a window pops up to let you follow the various initilization steps SUPERVISORY SYSTEM USER MANUAL v 1 0 21 1 18 2 Electrosys ilelco GSM Modem Setup sending PIN Number FIM Mat Requested Waiting Far Registration Registration Checking Signal Quality Signal OK 6 3 dBm Sending Init String lnitialization Current Action GSM Setup OF GSM Setup completed Exit The steps performed are Step 1 Modem presence and security password PIN if requested If the modem is present and it needs a security password the supervisor sends the number that you put in the SISSUP32 INI file If something goes wrong i e you have provided a wrong PIN number the initialization will be stopped to avoid the SIM card lock it happens after three wrong PIN numbers Step 2 Network registration The modem waits for the signal from the network operator this phase is repeated up to ten times Step 3 Signal quality check Low Signal 79 dBm Step 4 Initialization of parameters In this step the commands specified in the init string will be sent to the modem At the end of the initialization the result is showed and it stays on the screen for 2