Contents

1. 15 5 2 INTERNAL WEIGHT CALIBRATION LI c _ ii _ ai EE 16 2 Password A AU AYAU AE 17 5 3 INTERNAL FUNCTION SETTING LI i Ni err 18 2 Internal Function Parameter aani do tee d Sg 19 2 Error Messag ud NN MILII INI 20 CHAPTER 6 gt SPECIAL 21 6 1 ANIMAL SCALE FUNCTION SETTING 21 6 2 DUAL RANGE RESOLUTION SWITCH FUNCTION 22 6 3 PRETARE FUNCTION coria a 23 6 4 RESOLUTION SWITCH FUNCTION eese nena LLALL LLALL sana LL Y ERR anna au 23 www tanhiepthanh com vn FM User Manual 1 SMES000001 19 EXCELL PRECISION CO LTD 7 1 01 RS232 RS485 SERIAL OUTPUT WITH 4 21 3 24 2 Allocation of Rear Panel uuuu LLI tte tete ld 24 2 Connection Description HS485 totas t ca c t e e epe ie bee Tn 25 CHAPTER 8 FUNCTION PARAMETER SETTING 26 ra E IT 8 1 FUNCTION SETTING 121 1 AA NANA APA AA AA 27 2 Function Parameter 28 _ B2 RS232 SETTING Ll da 29 2 OP 01 RS232 RS485 Interface Function 30 2 Transmission Format arena 32 2 Command Mode
2. command is not correct it will reply E Command Unidentified If setting command mode with address RS1 06 4 add address in front of each command Example When RS1 08 1 for reading weight value the whole complete command should be 01RW CR LF www tanhiepthanh com vn FM User Manual 33 SME3000001 19 EXCELL PRECISION CO LTD Chapter 9 Maintenance ANH 9 1 Default Recovery for All Parameters 1 Adjust the calibration switch to ON when re zeroing after turning on press and hold simultaneously 2 The screen will display 1i 11 1111 3 If decided press and hold until displaying Ic a and then adjust the calibration switch to OFF 9 2 Default Recovery for General Function Parameters 1 When re zeroing after turning on press and hold simultaneously 2 The screen will display 11 12 17 3 If decided press L and hold until re turning on 9 3 Self diagnosis Mode 1 When re zeroing after turning on press and hold FIT _ 2 The screen will display Ic which means entered self diagnosis mode 3 Use a keys to select item intended to test Press key to enter self diagnosis and press o key to escape Display Testing Item Program Version Number Displaying 7 segment Display Testing Keypad and Calibration Switch Testing AD Conversion Value Displaying EEPROM Testin
3. ENTER O Press 155 to escape Back to general weight display status II iiL External function setting 1 L1 I i RS232 RS485 interface function www tanhiepthanh com vn FM User Manual 26 SME300000119 EXCELL PRECISION CO LTD CAN DIEN AY TAN HIEP THANA 8 1 Function Setting I dits Parameter Code Press E mL TIN Key Disable _ Tur DSP Update Input the parameter F1 Key Function Setting code intended F2 Key Function Setting KI E Backlight Setting The screen displays the parameters set previously Input the parameters intended and then ess a Continue other function settings or press to escape zo To add the value flashing ESC To reduce the value flashing lu 5 move the cursor leftward To move the cursor rightward eB laf U z 3 m E Storage setting Bet To abort setting or escape www tanhiepthanh com vn FM User Manual 27 SME300000119 EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH 2 Function Parameter Setting Parameter Funci n Setting i Parameter Description GROSS FF EJ F a from left to right No Limit i 20 times sec Key Disable 2 DSP Update 1 times sec Print printing F1 Key Function Setting Pre tare pre tare function Print printing F
4. EXCELL PRECISION CO LTD T GROSS P TARE MOTION Mt e ENTER User Manual Excell Precision Limited 2006 All rights reserved Worldwide The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied www tanhiepthanh com vn FM User Manual SME300000119 e EXCELL PRECISION CO LTD CAN DP SAFETY PRECAUTION SER ERF EEERO DRUD Ue PESE 3 CHAPTER 1 gt FEATURES AND SPECIFICATION 4 A O ne 4 1 2 SPECIFIC TO Ni 5 lt CHAPTER 2 gt KEYPAD OPERATION INSTRUCTION 6 CHAPTER 3 gt FRONT 8 REAR 5 7 3 1 FRONT PANEL iii 7 REPA HEAR PANEL cid ds 8 CHAPTER 4 gt 9 A AA 9 4x2 DIMENSION it 10 4 3 BATTERY ASSEMBLY asii GO uu a i O Dw UO Gan Galwn Y MEG 11 CHAPTER 5 gt INTERNAL CALIBRATION 12 5 1 SPECIFICATION SETTING Li i E NA AA 13 2 Specification Parameter Description sese 14 2 Parameter Display Description
5. Sampling Rate No limit Animal Scale Mode Mode 1 No weight display nder unstable status under stable or unstable status Animal Scale Mode 2 Stable Range Setting 8 times Stable Range Animal Scale Sampling Frequency 32 times 128 times Multi interval Dual Range Resolution Setting Multi range Dual Range Resolution Middle Point Setting www tanhiepthanh com vn FM User Manual 0 65535 19 SME300000119 excel EXCELL PRECISION CO LTD DIEN TU TAN MIEP THANA x Load Cell or A D circuit extraordinary 2 i Real weighing value lt zero value 3 i Internal resolution lt 0 12uV D range 4 i nr Incorrect password 5 i I Turning on zero lt zero range 6 i c Turning on zero gt zero range www tanhiepthanh com vn FM User Manual 20 SME3000001 19 EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH lt Chapter 6 gt Special Function 6 1 Animal Scale Function Setting 2 CFN 05 1 Animal Scale Mode1 No weight display under unstable status When no any object is on the platter the screen will display When the object is on the platter after weight has been measured the screen will display If the display weight value keeps being lower than zero plus 10d the screen will display 2 CFN 05 2 Animal Scale Mode 2 Weight display weather under unstable or stable status When the weight val
6. ettet tette t 33 CHAPTER 95 MAINTENANCE 34 9 1 DEFAULT RECOVERY FOR ALL 34 9 2 DEFAULT RECOVERY FOR GENERAL FUNCTION PARAMETERS 34 9 3 SELF DIAGNOSIS MODE siria 34 9 3 1 Program Version Number ee ee ee o reds cde eet n oNV tpe apapap aaa 35 9 3 2 7 segment Display Testing sss 35 9 3 3 Keypad amp Calibration Switch Testing esses 35 9 3 4 AD Conversion 2222 4 4 002 0 000000000000000000000 35 9 3 5 EEPROM Testing iei rete dere edet n CONOR SAW ES Musa SAD eae yn OFO 35 9 3 6 RTC Time amp Date entente 35 9 3 7 RS 232 Serial Output Interface Testing OP 01 sss 35 www tanhiepthanh com vn FM User Manual 2 SMES000001 19 e EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH BEFORE USING THE INDICATOR Thanks for purchasing EXCELL FM Mini indicator In order to operate smoothly to last the durability and to reduce the chance of breakdown for this product please read the following instructions carefully Safety Precaution amp Turn off power before installing or disassembling amp Keep the product away from sunshine The temperatu
7. or key according to FNC setting the screen will display 10 times resolution and then recovery back to original after 5 seconds www tanhiepthanh com vn 23 SMES000001 19 FM User Manual e EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH Chapter 7 gt Transmission Interface 7 1 OP 01 RS232 RS485 Serial Output with RTC To short 1 and 2 pins is RS485 output To short 2 and 3 pins is RS232 output 2 Pin Allocation of Rear Panel 4 RS485interface is capable to connect up to 10 mini indicators www tanhiepthanh com vn FM User Manual 24 SME3000001 19 EXCELL PRECISION CO LTD 2 BD Nel AN HEP THANH OU Terminal Resistant DA e 7 DB SG Host P DA DB SG e EX0419 1 RS 06 01 DA DB SG fam EX0419 2 RS 06 02 DA DB SG EX 0419 10 RS 06 10 4 Notice e lf the terminal resistant is built in the host interface it s not necessary to connect with another one outside Ifthe host computer is no signal ground SG it s not necessary to connect with it www tanhiepthanh com vn FM User Manual 25 SME300000119 e EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH Chapter 8 gt Function Parameter Setting Under general weight display status press and the screen will display ENTER TARE TT Press key Press
8. 2 Key Function Setting Pre tare pre tare function i Auto Backlight On Backlight backlight operation only Setting Backlight Off www tanhiepthanh com vn FM User Manual 28 SME300000119 EXCELL PRECISION CO LTD CAN DIEN JU TAN HIEP THANH 8 2 RS232 Setting 1 FE Press c 17 LILI Information Pattern i Transmission Method Transmission Rate Input the Parameter rolg code intended Parity Bit Length Stop Bit Unstable or Over Load Auto Transmission Condition The screen displays Command Address the parameters set previously Input the gt 11i Output Format parameters intended and then press enter i Transmission Times Date Setting Time Setting Continue other functions setting or press to escape To add the value flashing To reduce the value flashing fu 5 move the cursor leftward To move the cursor rightward m m z zi m Storage setting m o o To abort setting escape www tanhiepthanh com vn FM User Manual 29 SME300000119 e EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH 2 OP 01 RS232 oum Interface Function Setting Default Parameter Function i Code Parameter Description Setting Display Correspondingl i Information i Pattern p Conti
9. Default Function i Code i Parameter Description Setting Decimal Point Refer to the description on next page 999999 Capacity sh Max value for weight display 000000 999999 Division 1 j Min value for weight display Division 2 Min value for Weight display Zero Tracking Setting i Unstable CSP 05 i Detecting Setting Refer to the description on next page Refer to the description on next page www tanhiepthanh com vn FM User Manual 14 SME3000001 19 EXCELL PRECISION CO LTD 2 TAN THANH CSP 00 Decimal Point Decimal Point Digit None 1 Digit 2 Digits 3 Digits 4 Digits CSP 04 Zero Tracking Setting Display Division Period 0 25 D 1 sec 0 5 D 1 sec 0 75 D 1 sec 1D 1 sec 1 25 D 2 sec 1 5 D 2 sec 1 75 D 2 sec 2 D 2 sec No Zero Tracking CSP 05 Unstable Detecting Setting Display Division Period 0 25 D 1 sec 0 5 D 1 sec 0 75 D 1 sec 1D 1 sec 1 25 D 2 sec 1 5 D 2 sec 1 75 D 2 sec 2 D 2 sec No Unstable Detecting www tanhiepthanh com vn FM User Manual 15 SME300000119 e EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH 5 2 Internal Weight Calibration LL Turn on and warm up the machine for 15 to 30 minutes before calibration Adjust calibration switch to ON and the screen will display E
10. Display Frequency 50 times sec max Display Range 999999 999999 Min Division 1 2 5 10 20 50 Decimal Point O 0 0 0 00 0 000 0 0000 Memory Calibration parameter and function setting are all stored in EEPROM 9 9 9 9 Optional Interface OP 01 RS 232 RS 485 Includes RTC Function Power Reguirement Adaptor Spec Input 120 230VAC 50 60Hz output 9V 1000mA 6V 5pcs Hi MH rechargeable battery kit 1800mA 1hr Max Power Consumption by rechargeable battery 120mA with 4 Load Cells backlight RS 232 interface 15 hours 50mA with 1 Load Cell no backlight no RS 232 interface 36 hours Operation Temperature 10 C 40 C Operation Humidity lt 85 R H e Dimension W 49 5 x L193 x H134 mm Weight 700 www tanhiepthanh com vn FM User Manual 5 SME300000119 EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH Chapter 2 gt Keypad Operation Instruction Function Operation Press and hold and then press Adjust calibration switch to ON Description General Function Setting Refer to Chapter 8 gt Function Parameter Setting for details Setting for decimal point capacity i division zero tracking and unstable detecting etc Refer to 5 1 Specification Setting for details Weighing Parameter Setting Adjust calibration switch to ON Refer to 5 2 Internal Weight li Calibration Calibration for opera
11. EE THANH 5 3 Internal Function Setting Press Parameter Code IL i ri ttt gt Tare or Zero Function under Unstable Status Input the Parameter L Er ii 1 Turning on Re zero code intended Re zero Range gt Filter Strength Li AD Sampling Rate 1 Animal Scale Mode The screen displays the parameters set previously Input the parameters intended IL Fr Lt Animal Scale Sampling and then press Frequency Dual Range Resolution Setting 1 Animal Scale Stable Range gt Dual Range Resolution Middle Point Setting Continue other functions setting or press Q Je escape ESC To add the value flashing TARE To reduce the value flashing To move the cursor leftward To move the cursor rightward lm ed m z zi m E Storage setting To abort setting escape O ES www tanhiepthanh com vn FM User Manual 18 SME300000119 2 Parameter Function Code i Tare or Zero i Function under i Unstable Status i Parameter EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH Internal Function Parameter Description i Default Setting Description Setting Re zeroing after Turning on i Re zero Range 096 Full range re zero 1 3090 Capacity x setting value Filter Strength Strength increases by number AD
12. Z IiI 201 Press to select Li Z I nur emer LM cero Z librati let ESC ENTER ENTER 22 eight mass and and set the weight Weight Calibration Calibration Switch OFF Zero Calibration a ensure nothing on the platter after being stable press and the screen will display m The zero calibration will be complete 5 seconds later b To abort zero calibration just press Weight Calibration a Place an object whose weight is known on the platter and input the weight value from front panel After being stable press and the screen will display The weight calibration will be complete 5 seconds later b To abort weight calibration just press 1 ESC www tanhiepthanh com vn FM User Manual 16 SME3000001 19 AN DIEN TU TAN HIEP THANH 2 Password Setting Adjust calibration switch to ON After 2 seconds Input new password 4 0000 means no password Confirm new password re input again setting mode the screen displays F i for 1 second and then 1 Li Li li It s necessary to input the correct password to continue each setting 4 After complete password setting when entering calibration mode or function If the password inputted is not correct the screen displays www tanhiepthanh com vn 17 SME300000119 FM User Manual EXCELL PRECISION CO LTD CAN DIEN TU HI
13. ation for weight value The other 7 digits including decimal point represent the weight value If the weight is over load Header 1 OL the screen turns into blank except indication and decimal point Unit Kg g t Ib or blank Terminators CL and LF are data termination code RS1 00 4 T 1 12 CR LF RS1 00 5 T W l l t2 3 4 516 CRILF RS1 00 6 A T 2 CR LF x x x xX X X cR LF G R O 5 112 3 14 516 g N E T a 4 mos 4 5 16 9 CR LF 516 g CR LF T N X X CRILF TW 1112 314 516 CRILF www tanhiepthanh com vn FM User Manual 32 SME300000119 cv EXCELL PRECISION LTD CAN DIEN TU TAN HIEP THANH 2 Command Mode Command Function Command Function READ RW Weight Reading CT Tare Clearing ZERO MZ Weight Re zeroing RI _ Weight Accumulation TARE MT Gross Weight Reducing Rm Times Accumulation NTGS Gross Net Switch Hn Date MG Gross Weight Indicating Ro Time Weight and Times Accumulation Weight and Times Accumulation Clearing MN Net Weight Indicating AT DT After setting the commands mentioned above it s necessary to add the termination code CR ODH and LF OAH
14. g RTC Date amp Time Testing FM User Manual 34 SME300000119 EXCELL PRECISION CO LTD s31 HIEP THANH 7 segment display reveals program version number 9 3 2 7 segment Display Testing 7 segment display reveals 4 1 s Tr and 9 3 3 Keypad amp Calibration Switch Testing Adjust calibration switch to ON and press any key the corresponding bit will be changed from gt 9 3 4 AD Conversion Value 7 segment display reveals the internal value of the present weight 9 3 5 EEPROM Testing Displaying r Displaying Z is 1 represents in normal condition I iy 1 11_ represents in extraordinary condition 9 3 6 RTC Time amp Date Testing Press ED key to enter the testing mode and the screen will display date XX XX XX Example 05 11 03 represents 3rd of November 2005 Press EER key again to display time XX XX XX Example 09 45 50 represents 9 o clock 45 minute and 50 seconds 9 3 7 RS 232 Serial Output Interface Testing OP 01 1 Short the 2 pin and 3 pin of the SER OUT D SUB socket Displaying i Displaying i E represents in normal condition 1 11_ represents in breakdown condition 2 If connected with a computer protocol must be corresponding the screen will LI LI display IL 21 which means RS 232 output is in normal condition www tanhiepthanh com vn FM User Manual 35 SME300000119
15. g zero 1 Weight re zero 2 To add the value when setting 2 To reduce the value when setting 88955 1 To switch Gross Net weight shown on display 2 To move the cursor leftward when setting 1 Keypad function FNC 02 amp FNC 03 TARE 1 To eliminate the gross weight 2 To move the cursor rightward when setting Keypad function FNC 02 amp FNC 03 Confirmation key www tanhiepthanh com vn FM User Manual 7 SMES000001 19 e EXCELL PRECISION CO LTD GAN DIEN TU TAN MIEP THANA 5 To 1 Battery Case 2 RS232 485 Input Output 3 DC 9V Power Input 4 Calibration Switch 5 Load Cell Connect Socket www tanhiepthanh com vn FM User Manual 8 SME300000119 EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH Chapter 4 Installation 4 1 Load Cell 5 4 211 O a 999 939 L oad cell cable Load cell aO PAN PAN SEN 516 SIG T SEN LJ VET Sh
16. ield 4 wired 5 wired Load Cell 6 wired 7 wired Load Cell Short Pin4 amp 5 to connect with EXC Pin5 connects with EXC Short Pin2 amp 3 to connect with EXC Pin4 connects with SEN Pin1 connects with SIG Pin3 connects with EXC Pin9 connects with SIG Pin2 connects with SEN Pin6 7 8 connect with Shield Pin1 connects with SIG Pin9 connects with SIG Pin6 7 8 connect with Shield www tanhiepthanh com vn FM User Manual 9 SMES000001 19 e EXCELL PRECISION CO LTD 42 Dime QAN DIEN TU TAN HIEP THANH 600 193 0 z495 KI fii BI a Os A bE obesa 5 TO ocd 76 CA www tanhiepthanh com vn FM User Manual 10 SME300000119 EXCELL PRECISION CO LTD AN DIEN TU TAN HIEP THANH 4 3 Battery Assembly y MW Stuff the surplus wires i
17. nto the battery case www tanhiepthanh com vn FM User Manual 11 SME300000119 EXCELL PRECISION CO LTD Chapt r 5 gt Internal Calibration Adjust calibration switch to ON and the screen displays After 2 seconds ENTER 8 ESA Adjust calibration switch back to OFF Specification Setting LL Internal Weight Calibration m L 1 Internal Function Setting www tanhiepthanh com vn FM User Manual 12 SME300000119 EXCELL PRECISION CO LTD CAN DIEN TU P THANH 5 1 Specification Setting ar Press T Decimal Point L 2I TIL gt Capacity Input the Parameter or Ez Division 1 Code intended Fn rr or L 1 1 1 Division 2 Zero Tracking Setting 1 Unstable Detecting Setting The screen displays the parameters set previously Input the parameters intended and then press Continue other functions setting or press to escape Esc To add the value flashing Mu To reduce value flashing To move the cursor leftward To move the cursor rightward eaj 590 U m z 3 m m Storage setting Bs it To abort setting escape www tanhiepthanh com vn FM User Manual 13 SME3000001 19 excel EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH 2 Specification Parameter Description Parameter Setting i
18. nuous Transmission i Transmission i i i Press or to transmit Method Command Mode with address 1200 I Transmission Rate 19200 No Parity 8 Bits Length Parity Odd Parity Bit Length 7 Bits Length Stop Bit Even Parity 7 Bits Length 1 Stop Bit Unstable or Continuous Output Over Load Stop Output Positive over 10D i Transmission Positive negative Condition over 10D under 10D Command TT E Address only if RS1 01 setting is 4 Output i Standard Format Format UMC 600 www tanhiepthanh com vn FM User Manual 30 SME300000119 e EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH 0 Limit i i Transmission BEEN Times 5 20 times sec RS1 09 i Date Setting RS1 10 iTime Setting www tanhiepthanh com vn FM User Manual 31 SME3000001 19 EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH 2 Transmission Format RS1 00 gt 0 3 SIT GS 1 111213141 1516 g CR LF J N J Header 1 Header 2 Weight Data 8 digits Unit Terminators Header 1 ST Stable Weight US Unstable Weight OL Weight Over Load Header 2 GS Gross Weight Weight TR Tare Weight Data 8 digits The first digit of weight data represents indic
19. re range for operation is 10 C 40 amp _ To connect the ground is a must for this equipment The ground impedance is less than 1000 amp _ Never connect the ground with other eguipments which are huge in power consumption amp No ground or incorrect ground connecting might cause the electric shocks or breakdowns www tanhiepthanh com vn FM User Manual 3 SME300000119 EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH Chapter 1 gt Features and Specification 1 1 Features Large and clear LCD height 25 4mm x 10mm LED Backlight more duration more energy saving Auto zero tracking Weighing calibration in both kilogram and pound High resolution switch function to display 10 times divisions Weighing unit shift function amp data accumulation function Adjustable digital filter Available in connecting with up to four 350 ohm load cells Capable of connecting with 6 wire load cells Convenient to operate power switch in front panel www tanhiepthanh com vn FM User Manual 4 SME300000119 excel EXCELL PRECISION CO LTD sec ANDIENTUTANHIEPTHANH Analog Specification Load Cell Current DC 5V 5 60mA Up to Four 3500 Load Cells Max Load Cell Input Voltage 16 mV Input Sensitivity 0 120 V D or more Conversion Rate Approximately 100 times sec max Resolution 19 bits 9 9 9 Digital Specification Display LCD 6 digits height 25 4x10mm LED backlight
20. tion i While turning on with i i countdown press and i hold Ea Self diagnosis Mode Refer to 9 3 Self diagnosis Mode for details Adjust calibration switch press Refer to 9 1 for details for All Parameters iand hold r1 arm E i While turning on with for General Function i countdown press and ENTER nao rj Refer to 9 2 for details Parameters i 4 During the operation use the following keys to complete all the works ZERO To add the value flashing Fa To move the cursor rightward Bu 4 gt 2 reduce the value flashing 4 Storage setting gross To move the cursor leftward To abort setting to escape Wii n www tanhiepthanh com vn FM User Manual 6 SMES000001 19 EXCELL PRECISION CO LTD CAN DIEN TU TAN HIEP THANH lt Chapter 3 gt Front amp Rear Panels 3 1 Front Panel lt D EELE FM mo MS TARE MOTION M GROSS PT ZERO Bl Dd F2 Fl E gt E E Indication F1 Battery charged status Battery charging status TARE Tare status MOTION Unstable weighing indication Ma Accumulation status indication GROSS Gross weight PT Pre tare Keypad 1 1 Power ON OFF Press and hold this key for 3 seconds to shut down ESC 2 To abort or escape when settin
21. ue reaches the range of CFN 06 and CFN 07 setting the screen will Keep displaying the weight value When the weight value is over the range of CFN 06 and CFN 07 setting the screen will display the normal weight measurement Example CFN 06 30 CFN 07 2 WT Weight Holding 30d y lt gt Weight Holding Cancellation 10d T www tanhiepthanh com vn 21 SME300000119 FM User Manual EXCELL PRECISION CO LTD 62 Dua HANH If the setting of CSP 02 is not the same as CSP 03 the dual range resolution will be activated 2 08 0 Multi interval If CFN 09 5000 WT Division 2 p 5000 ES Division 1 2 08 1 gt Multi range If CFN 09 5000 WT 5000 Recover when back to zero www tanhiepthanh com vn FM User Manual 22 SME3000001 19 AN DIEN TU TAN HIEP THANH 6 3 Pre tare Function 2 02 or FNC 03 setting is at parameter 6 Pre tare Function Under weight display status press Ka or 22 key according to FNC setting the screen will display Input the pre tare value intended Press EF key Back to weight display status PT indication lights up Pre tare Cancellation TT When the gross weight is displayed as O press key to cancel the pre tare value 6 4 Resolution Switch Function 2 FNC 02 or FNC 03 setting is at parameter 5 HR Under weight display status press E