Home
your easywind software manual
Contents
1. EasyW Software Manual Software Manual 1 28 EasyWind Software Manual leasyu INDEX CONTEXT Object of this document Introduction to EasyWind COMPONENTS DETAILED COMPONENTS EASYWIND RECEPTION UNIT EASYWIND SENSOR DATA POWER CABLE CONNECTORS INSTALLATION SENSOR CONNECTION SENSOR PLACEMENT RECEPTION UNIT CONNECTION USAGE RECOMMENDATIONS SETTING UP EASYWIND BEFORE YOUR FIRST SAMPLE Conventions and default values EASY WIND AUTO CALIBRATION COMPASS CALIBRATION RESET FACTORY DEFAULT DAMPING USE COG TO CALIBRATE ACCESS EASYWIND SOFTWARE Availability Sections WIND CONDITIONS REAL TIME STATS Time Selector True Wind Direction Relative to Mean True Wind Speed AMBIENT CONDITIONS BOAT CONDITIONS VIEW HISTORY Session Calendar Session Details Export Import SYSTEM CONFIGURATION Screen Options Wind Sensor Calibration Version 1 3 2 28 EasyWind Software Manual easyu e Identifiers Management Wifi Settings Software Update CHECKS RECEPTION UNIT POWER SUPPLY INDICATOR CONNECTING THE RECEPTION UNIT TO THE INTERNET HELP ABOUT EASYWIND RELEASE NOTES Version 1 3 EasyWind Software Manual CONTEXT Object of this document The object of this document is to introduce users to EasyWind and how to use its components available features and functions in order to ensure a correct and optimised management of the product Introduction to EasyWind EasyWind obtains wind conditions
2. RECEPTION UNIT PORTABLE MOBILE TABLET DEVICE 1 Ensure your reception unit is connected to power 2 Connect to EasyWind WIFI network using your smartphone or tablet Once the reception unit has been powered the wifi network may take from 15 to 60 seconds to show up This time may vary according to the smartphone or tablet which is being used 3 In your browser GOTO URL 192 168 42 1 4 GOTO menu option SYSTEM CONFIGURATION 5 Within the SCREEN OPTIONS revise the following settings are according to your needs Y WIND SPEED UNITS Y MAGNETIC DEVIATION Y TIME ZONE Y REAL TIME STATS VISUALIZATION SETTINGS 6 Within the MANAGE IDENTIFIERS toggle please give your EasyWInd an ALIAS NAME write on the text field and click on the UPDATE BUTTON to save 7 Change your WIFI NETWORK name and password Do not forget to save your settings Y DEFAULT WIFI NAME PROVIDED IN YOUR EASYWIND DELIVERY NOTE Y DEFAULT WIFI PASSWORD easywind NOTE WELL YOUR NEW EASYWIND NAME AND PASSWORD BEFORE MODIFYING THESE SETTINGS Version 1 3 8 28 EE S y Softwa o tial In order to make effective your new wifi settings you will need to POWER OFF and POWER ON your reception unit and reconnect to your new wifi network with the new name and password YOUR EASYWIND EQUIPMENT IS NOW READY TO PROVIDE YOUR FIRST SAMPLES Conventions and default values Y 1 SAMPLE N Measurements Y TIME UITC Y WIND SPEED DEFAULT UNITS m s ACCESS EASYWIND
3. 5505550555005500550055N555655560605560656500656065006000650 AAA rr rr rr rr rr rr rr rr reses BOAT CONDITIONS This window has been designed to display real time boat conditions displayed variables may vary according to the brand and type of sensor HDG Boat Heading Degrees SOG Boat Speed Over Ground COG Boat Course Over Ground Degrees PITCH ROLL YAW Boat Pitch Roll useful and Yaw if available Degrees XN NNN These values are useful for the initial calibration of the sensor eve o PITCH 0 2 1 8 ROLL 0 Version 1 3 15 28 Ba P EasyWind eaSyuind T T ny VIEW HISTORY Session Calendar This window will display a calendar which will include the sessions which have been carried out with EasyWind Y DATE SELECTOR Quick selection of a given date Y DATE SELECTION ARROWS Allows users to move between dates sequentially or to select today s date Y DAY WEEK MONTH VIEW Day week month calendar view selector DEFAULT VALUE MONTH Y IMPORT OPTION Described separately HERE Select day yyymmca lt gt today April 2014 month week day 10 05a2 POR7 Alrmar PB150 6 17p3 POR7 Airmar PB150 8 13a4 POR7 Airmar PB150 12 45p 5 POR7 Airmar PB150 start 2014 04 01 18 17 33 start 2014 04 02 08 13 58 start 2014 04 03 12 45 59 end 2014 04 01 22 30 38 end 2014 04 02 14 54 57 end 2014 04 03 13 58 25 8 14a6 POR7 Airmar PB150 start 2014 04 04 08 14 48 end 2014 04 04 14 19 41 star
4. aware when using this feature that Heading and COG are not the same Heading refers to the direction the bow of the vessel is pointing COG refers to Me direction the vessel is traveling While in an automobile these values are likely to be nearly identical in a boat they can differ because of the effacts of wind and current on the vessel The rationale for using COG instead of heading in the calculations for vwe wind is thal the difference between COG and actual heading might be less than the error in the reported compass heading due to de ENABLE COG DISABLE COG Version 1 3 24 28 aa P EasyWind easywind a Identifiers Management In this section you can provide an alias for your EasyWind Reception Unit Furthermore in case of importing samples from other EasyWind Reception Units alias can be given to them too in order to be able to difference samples from different Reception Units Unique identifiers are provided for each EasyWind Reception Units which cannot be modified in any way Wifi Settings This section provides the possibility of changing the name and password of the wifi network created by EasyWind Reception Unit It is mandatory in the case other EasyWind Reception Units are being used within the same area Y Input your new wi fi name Y Input your new wi fi password Y Make sure you remember your new wi fi settings Y Power off and on your reception unit in order for the changes to take effect Software Update Eas
5. information from an ultrasonic meteorological sensor and displays it in a user friendly web interface accessible by portable devices such as mobile phones and tablets via a wireless network COMPONENTS Ultrasonic Wind sensor Reception Unit Data Power Connection Cables Y Power data cable Y Micro USB Y Ethernet cable DETAILED COMPONENTS EASYWIND RECEPTION UNIT 1 Lock fasteners 2 Clasp Version 1 3 4 28 ee SYwind Softwa a a EASYWIND SENSOR 1 Ultrasonic sensor 2 Sensor nut 3 Base DATA POWER CABLE CONNECTORS 1 Power data connector to sensor 2 Data connector from reception unit to sensor 3 Power connector from reception unit to support boat Version 1 3 5 28 EE SYwind Softwa an a tial INSTALLATION SENSOR CONNECTION 1 Unscrew sensor base from sensor 2 Pass power connector to sensor through the sensor base 3 Connect power connector to sensor 4 Screw sensor base to sensor 1 o 3 SENSOR PLACEMENT 1 Fix the sensor base upon a wind mast in the support boat Make sure the sensor dent exactly matches the bow of the support boat In order to ensure this once EasyWind is connected and working GOTO the BOAT CONDITIONS MENU and check that the boat s heading not COG matches a manual compass reading or known bearing 2015 02 01 03 16 34 03 16 33 h HDG SOG knots 344 0 COG o PITOH 58 58 gt ROLL 44 Version 1 3 6 28 8g Ss y Softwa
6. wind direction numerical mean value ORANGE TEXT Y BUTTON Enlarges moving average window to display a smoothened mean curve Y BUTTON Shortens moving average window to display a more reactive mean curve Y Default value for the moving average window is set at the SYSTEM CONFIGURATION SECTION Y This setting is synchronised with the TRUE WIND SPEED graph below Y TRUE WIND DIRECTION RELATIVE TO MEAN True wind direction values Represented as a BLUE LINE which will be printed dynamically according to time and relative to the mean value Y LAST VALUE Displays the numerical last wind direction measurement BLUE TEXT If user clicks upon the value the TRUE DIRECTION RELATIVE TO MEAN LINE will hide from the graph Re displayed when clicked upon again toggle display Y PORT Displays the minimum PORT or left value relative to the mean RED TEXT Version 1 3 12 28 8g Ss y Softwa mre tet Y STBR Displays the maximum STARBOARD or right value relative to the mean GREEN TEXT Y WIND INTENSITY GRAPH Represented by a grey shadow area graph displays the wind intensity related to its mean according to time This enables users to rapidly detect and compare wind direction changes related to intensity variations TIME Version 1 3 Y_ If graph curves to the right hand side wind intensity is GROWING Y If graph curves to the left hand side wind intensity is DECREASING Y BUTTON Enlarges moving average window to
7. Time Stats Ambient conditions po ZA l amp Boat conditions A w View history System configuration Help About EasyWind TIP Clicking on the top bar at any of the windows and sections always returns the user to the index menu page The wind sensor AUTOMATICALLY CONNECTS to the RECEPTION UNIT and a connection icon is displayed at the right hand side of the top bar If displayed connection icon is disconnected please click on it to connect manually Version 1 3 10 28 easywind Sean eee WIND CONDITIONS This window has been designed to display real time wind conditions Y WIND DIRECTION ANGLE In degrees Y WIND CARDINAL DIRECTION Cardinal direction Y WIND SPEED Units can be configured from the SYSTEM CONFIGURATION SECTION TRUE WIND CONDITIONS 1 11 Knots REAL TIME STATS This window has been designed to display real time wind statistics via a graphical display Time Selector Exclusive toggle buttons which enable the user to choose 5 measurements time windows Default times are 1 5 10 15 30 these can be modified according to the users needs via the SYSTEM CONFIGURATION SECTION T Displays wind measurements for the last minute 5 Displays wind measurements for the last 5 minutes DEFAULT VALUE Y Y Y 10 Displays wind measurements for the last 10 minutes Y 15 Displays wind measurements for the last 15 minutes Y 30 Displays wind measurements f
8. Your EasyWind software is available via your web browser through your EasyWind wifi network at the following URL 192 168 42 1 You will be able to access your EasyWind website via any tablet mobile device or PC with a wifi connection module Follow the below steps to access EasyWind 1 Power ON your Reception Unit 2 Connect to EasyWind WIFI network using your smartphone or tablet 3 In your browser GOTO URL 192 168 42 1 4 Welcome to EasyWind Version 1 3 9 28 Ba f EasyWind eaSyuind Softwa a a ul SOFTWARE Availability Your EasyWind software is available via your web browser through your EasyWind wifi network at the following URL 192 168 42 1 You will be able to access your EasyWind website via any tablet mobile device or PC with a wifi connection module Sections EasyWind Website main menu consists of the following options each of them will be further detailed in this user Guide Y WIND CONDITIONS Displays numerical values regarding real time measurements Y REAL TIME STATS Displays statistics regarding real time measurements Y AMBIENT CONDITIONS Displays real time ambient conditions measurements Y BOAT CONDITIONS Displays real time boat conditions Y VIEW HISTORY In order to view your past EasyWind session calendar Y SYSTEM CONFIGURATION Configuration parameters Y ABOUT EASYWIND Learn more about EasyWind project Y HELP Help with EasyWind 2014 04 04 14 19 41UTC Wind conditions Real
9. a area away from other boats or ferrous objects structures or aids to navigation Y Check that the weather station instrument is correctly installed on the vessel and the unit under test is powered up and connected to the reception unit Y Access EasyWind Software Y GOTO menu option SYSTEM CONFIGURATION WIND SENSOR CALIBRATION Compass Calibration Configuration Wind sensor calibration Manage Identifiers Update Software Y PRESS START BUTTON the calibration screen will start flashing and will display IN PROGRESS Y Within 2 3 minutes slowly rotate the vessel 4 6 knots in a circular turn until the message changes to one of the following O OK CALIBRATED The calibration process has been successfully completed O TIME OUT The rotation motion is too slow and has been timed out O FAIL ERROR An error has occured repeating the process is recommended Airmar wind sensor calibration Compas calibration Calibration needs to be done in calm seas away from other boats or ferrous objects structures or aids to navigation Check airmar sensor calibration guide for more information 1 The weather station instrument is installed on the vessel The unit under test is powered up and connected to the reception unit 2 During the user calibration process the vessel is rotated slowly driven at 2 4 knots completing a circle within 2 3 minutes while the sensor collects data 3 Click on the start button 4 Wa
10. display a smoothened mean curve Y BUTTON Shortens moving average window to display a more reactive mean curve Y Default value for the moving average window is set at the SYSTEM CONFIGURATION SECTION MEAN WINDOW Y 30 45 90 180 Default view for user is 360 direction angle Upon clicked these values allow the user to configure a 30 45 90 180 degree view according to the current wind conditions FOR EXAMPLE If wind is stable direction changes will need a closer look and a 30 or 45 angle view may be necessary to appreciate wind shifts If on the contrary the wind is shifty a wider view may be needed TRUE WIND DIRECTION RELATIVE TO MEAN 195 200 ih 210 215 20 230 235 240 HA 250 255 06 Pel 05 PM oa PA MEAN 225 deg LAST 211 deg 03 PM ey PORT 109 deg STBD 235 deg 01 PM 12 PM gT 30 45 90 180 11 AM 195 200 6 210 215 220 z5 230 235 240 n 250 255 WIND RELATIVE TO MEAN 13 28 EasyWind easy JTI Software Manual True Wind Speed Graphical display for wind speed represented together with the mean value which will enable the user to view the wind speed change trends in time J S X AXIS Time axis displays values dynamically The overall data displayed depends on the time selector above described Y AXIS Wind speed values Units can be configured at the SYSTEM ONFIGURATION SECTION MEAN LINE Mean wind speed reference represented as an ORANGE LINE MEAN VALUE D
11. e following formats are available Y EASYWIND ew Own EasyWind format Y CSV csv CSV summary CSV sample list Y JSON json json Y Click on the EXPORT button Y Choose the FILE FORMAT you want your sample to be exported in Y Click on the EXPORT button Y Your samples will be available within your device s downloads folder Back to list Delete period laala r m mlb Export measurements x a ARA File Name leasywind wind TRUE WII TO MEAN Format Easywinc NOTE The exporting process may take a few minutes according to the amount of data within the exported session Version 1 3 20 28 EasyWind Software Manual Import EasyWind from your backups sessions or from other EasyWind Reception Units previously exported can be imported using EasyWind s format ew In order to import new sessions 1 Click onthe IMPORT button Choose the ew file from your local device by using the browsing window Click on the UPLOAD button E E Your samples will be available within your VIEW HISTORY calendar Import samples x Import file Choose File easywind ew Upload Lid gt today month week day Sat 6 7 NOTE The importing process may take a few minutes according to the amount of data within the imported session Version 1 3 21 28 aa 2e S Yuind Softwa eae SYSTEM CONFIGURATION Screen Options This section provides the possibility of configuring
12. e A RECEPTION UNIT CONNECTION 1 Connect data cable to reception unit 2 Connect power cable to reception unit 3 Connect power cable to support boat 12 Volts RECEPTION UNIT POWER CABLE 12 V 7 EasyWind compass within the wind sensor should be calibrated and ready to use when acquired however if it the sensor has undergone non usage periods and or heavy transport conditions it may require a calibration procedure Version 1 3 7128 Z P EasyWind easy Software Manual USAGE RECOMMENDATIONS Please follow the below recommendations for an optimal usage and results Y Before starting to use your EasyWind product read the full EasyWind manual carefully and refer to your EasyWind support team in case you have any doubt regarding how to use EasyWind Y Misuse will not be covered by EasyWind s Support Team or any warranty S Always ensure you perfectly close your EasyWind Reception Unit while carrying out samples Y When using EasyWind please ensure you are stopped or under a constant speed and direction else the sampling may be affected and the average values altered Y For security reasons and to prevent other EasyWind interferences change WIFI name and password before first use Please beware sharing EasyWind passwords as it may cause a network overload and or confusion with samples NOTE WELL YOUR NEW EASYWIND NAME AND PASSWORD BEFORE MODIFYING THE SETTINGS SETTING UP EASYWIND BEFORE YOUR FIRST SAMPLE
13. ind el Sywind Softwa ef al TRUE WIND SPEED J MAX 8 89 Knots MEAN 3 38 E py a MIM 287 Eros J H TY 5 5 A 3 3 L LIAM 1130 TIME Y MEASUREMENT MAP Session s positional route represented upon a map Reset zoom Overview zoom Hour 2014 07 29 15 12 00 B TWS 1 48 Knots TWD 299 Temperature 25 C Pressure 1015 Lon 2 64989 Lat 39 59383 Y SAMPLE DETAILS Full details about the session Version 1 3 NN NNN NSN Period Station Wind Speed Min Mean and Max Values Wind Direction Min Mean and Max Values Temperature Min Mean and Max Values Pressure Min Mean and Max Values Comments Not yet implemented Coming Soon 18 28 Details START July 29 2014 4 48 00 PM END July 29 2014 5 19 00 PM BRA_12 General stats wind speed Knots wind angle Temperature C 25 0 Pressure dbar 1014 00 101521 EasyWind Software Manual Y AMBIENT CONDITIONS Session s temperature and pressure conditions graphical display Air temperature Temperature L 09 30 10 AM 10 30 11 AM 11 30 12 PM 12 30 01 PM 01 30 02 PM TIME Pressure Le Y TALS a WN 09 30 10 AM 10 30 11 AM 11 30 12 PM 12 30 01 PM 01 30 02 PM TIME HT il TU LM MN 02 30 Version 1 3 19 28 EasyWind Software Manual Export Sessions can be externally exported for backup or analysis purposes within the SESSION DETAILS SECTION Th
14. ion 1 1 Y P3 Note on connection icon and possibility of manually connecting to sensor Y P10 Remove sample option Y P15 Enhanced update software section Version 1 2 Y New CONTEXT section Y New COMPONENTS section Y New CHECKS section Y New USAGE RECOMMENDATIONS section Y New SETTING UP BEFORE FIRST USE section Y New AUTO CALIBRATION section Y New ACCESS section Y New screenshot for Real Time Stats Wind Direction Y Explanation for new Degree view Y New screenshot for Real Time Stats Wind Speed Y New screenshot for configuration options Y Explanation for Calibration options Version 1 3 Y New detailed components section Y New installation section Y Check section moved to the end of the document Y New screenshot for Session Details Wind conditions Y Calibration section moved to System Configuration options Y Extended wi fi settings explanation Version 1 3 28 28
15. isplays the wind speed numerical mean value ORANGE TEXT Y BUTTON Enlarges moving average window to display a smoothened mean curve Y BUTTON Shortens moving average window to display a more reactive mean curve Y Default value for the moving average window is set at the SYSTEM CONFIGURATION SECTION MEAN WINDOW Y This setting is synchronised with the TRUE WIND DIRECTION graph above TRUE WIND SPEED True wind speed values Represented as a BLUE LINE which is printed dynamically according to time LAST VALUE Displays the numerical last wind speed measurement BLUE TEXT If user clicks upon the value the TRUE WIND SPEED LINE will hide from the graph Re displayed when clicked upon again toggle display TRUE WIND SPEED l MAX 3 33 Knots pu i MEAN 1 32 LAST 1 67 less al las 3 0 ao La 29 209 20 i is E IN 0 35 Knots 0 5 jos a 01 53 30 01 54 30 01 55 30 01 56 30 i P TIME Version 1 3 14 28 a A i EasyWind easywind Toe atl AMBIENT CONDITIONS This window has been designed to display real time ambient conditions these values may vary according to the brand and type of sensor Y AIR TEMPERATURE In Celsius Degrees Y PRESSURE In Bars Y DATE Date UTC Time Y POSITION Latitude Longitude AIR TEMPERATURE PRESSURE bars O 3 18 1014 LATITUDE DATE E 39 5013 2014 04 04 14 19 41UTC LONGITUDE 2 7499 rr 65 0555065560555 5606 0505 050506060505 655555655555 500505555555 55 5550
16. it until you see the message change from IN PROGRESS to OK CALIBRATED or FAIL ERROR Start calibration Calibrated Version 1 3 23 26 B y EasyWind easy al RESET FACTORY DEFAULT Upon clicked each of the buttons will reset the compass calibration damping configurations or both to the default values Reset compass calibration Reset damping factory default DAMPING Pitch Roll and the compass rate gyro can use damping procedures for greater accuracy The number of seconds taken into account in order to display the measured value can be configured within this window Damping 490 05 Pitch and roll seconds 19995 Compass RateGyro seconds Usa compass gira A Yes Y No Save changes USE COG TO CALIBRATE If the local magnetic inclination dip is severe this can produce errors in the compass heading when the vessel is not leveled Since the compass heading is used in the calculations for true wind this can also result in errors in the reported true wind speed and direction apparent wind is not affected The WeatherStation can be instructed to use Course Over Ground COG provided by the internal GPS in place of the internal compass heading in the calculations for true wind If this feature is enabled then the COG will be used instead of internal compass heading for calculation of true wind only if the GPS has achieved a fix and if the Soeed Over Ground SOG is greater than 3 knots If the
17. nes bp the pore Cena your bese tarios pa phe rete ating nan ade wake heck bere Spur un bisperanos See minem rape boat Gi Advanced Don t touch Version 1 3 26 28 al S Ywind Softwa Ap Ae a CHECKS RECEPTION UNIT POWER SUPPLY INDICATOR In order to verify that the reception unit is powered ON please ensure that the RED POWER LED is LIGHTED Power LED is most interior light to the left Enough batteries Empty batteries RED LIGHT NO LIGHT OR TILTING LIGHT CONNECTING THE RECEPTION UNIT TO THE INTERNET When ashore and wanting to update your EasyWind software internet connection is strictly required and or view the samples which have been carried out during the day you can connect your EasyWind Reception Unit to the Internet which will enable Internet via your EasyWind wifi network Please follow the below steps 1 Connect an ethernet cable not provided from the reception unit to the to an internet network connection Station or router not a PC 2 Check out the reception unit sLEDS colour code view LED location Connected to the Internet NOT Connected to the Internet AA A Troubles connecting to the Internet Visit our TROUBLESHOOTING section Version 1 3 27 28 a S Ywind Softwa Era ae HELP This user manual and other useful tips will be available for download within this section ABOUT EASYWIND Information about EasyWind project and partners involved RELEASE NOTES 01 09 2014 Vers
18. or the last 30 minutes Version 1 3 11 28 a 7 i EasyWind easy is baie 1 gt EO ES NOTE The web application may take longer in loading larger time frames due to the amount of managed data True Wind Direction Relative to Mean Graphical display for wind direction relative to the mean value which will enable users to view the wind direction change trends in time SCIENTIFIC NOTE The mean value is calculated as a moving average which is based upon a fixed set of the last values the sensor is providing moving average window The number of values which are taken to calculate the average will affect the mean the following way Y Less values shorter moving average window Mean reacts more rapidly to the latest trends Y More values longer moving average window Mean takes into account older values and therefore will show longer and smoother trends The following formula is being applied to calculate the moving average value value mean of N samples N N 1 Where N is the number of values taken into account for the moving average window Further information about moving average Y XAXIS Wind direction relative to the mean value centered at 0 and running from 180 to 180 Y Y AXIS Time axis which displays values dynamically The overall data displayed depends on the time selector above described Y MEAN LINE Represented by an ORANGE LINE centered line a the 0 Y MEAN VALUE Displays the
19. re is no GPS fix or if the SOG is 3 knots or less then the internal compass heading will be used Do be aware when using this feature that Heading and COG are not the same Heading refers to the direction the bow of the vessel is pointing to COG refers to the direction the vessel is travelling While in an automobile these values are likely to be nearly identical in a boat they can differ because of the effects of wind and current on the vessel The rationale for using COG instead of heading in the calculations for true wind is that the difference between COG and actual heading might be less than the error in the reported compass heading due to dip Use COG to calibrate ifthe local magnetic inclination dip is severe this can produce errors in the compass heading when the vessel is not level Since the compass heading is used in the calculations for true wind this can also resull in errors inthe reported bue wind speed and direction Apparent wind is not affected The Weather Station can be instructed to use Course Ower Ground COG provided by the internal GPS in place of the intemal compass heading in the calculations for true wind 14 this feature is enabled hen the COG wall be used instead of internal compass heading for calculation of rue wind anh d the GPS has achieved a lis and if ihe Speed Cee Ground S06 is greater than 3 knolle I there no GPS tik or it The SG amp 3 kins oF less Men The imernal compassteacing wall be used Do fe
20. some settings which affect EasyWind Y WIND UNITS Drop down menu for the user to select wind speed units Users can also introduce their own conversion factor if desired for example 1 m second 60 1 m minute CONVERSION FACTOR 60 Wind uns Sal Mom tie combo Gon Pe cient Uns O US any lactos bo diii YAE OA units The detail urls are m so ho tector will be 1 Label knots Factor 1852 Y REAL TIME STATS User configurable parameters for the real time stats section Y Label Label for the time periods to be displayed as toggle selectors Y Period Sampling time period to be displayed in seconds Y Mean Window moving average time window for graph filtering with the buttons J Display Blue Line Default value for the last value line graph toggle display Real me stas label max 3 char period seconds Mean window seconds display blue line y 180 10 ue 5 300 5 iue LO 600 60 tue 15 900 90 false ay 1300 180 Talse F Y TIME CONTROL Configurable user time zone DEFAULT VALUE IS UTC TIME CONTROL Local TIME Y MAGNETIC DEVIATION Users can introduce a magnetic deviation given the location they are in and this will taken into account in the sample results Version 1 3 22 28 we wd 4 EasyWind easywind ee Wind Sensor Calibration In order to calibrate the compass within the wind sensor an auto calibration procedure is provided please read carefully before proceeding Y Navigate to a calm se
21. t 2014 03 30 10 05 05 end 2014 03 30 12 03 45 NOTE Due to the large amount of data which is processed within this window loading operation may take some time please be patient until window is fully loaded Version 1 3 16 28 EasyWind Software Manual Session Details This window provides full information about a given sample Y EXPORT Described separately HERE Y REMOVE PERIOD Delete measurements of the day Remember to backup the information prior the deleting action Y SAMPLE FREQUENCY Time selector which enables user to view the session s details according to a higher or lower sampling per time period Window performance is affected when selecting higher sample frequencies please be patient and wait for the window to load completely 1 One sample per minute in order to calculate the mean values DEFAULT VALUE 30 One sample per every 30 seconds in order to calculate the mean values J J Y 20 One sample per every 20 seconds in order to calculate the mean values Y 5 One sample per every 5 seconds in order to calculate the mean values J 1 One sample per every second in order to calculate the mean values Back to calendar Measurement map Ambient conditions Y WIND CONDITIONS Session s wind conditions graphical display same as the REAL TIME STATS section TRUE WIND DIRECTION RELATIVE TO MEAN LAST 211 deg 220 5 20 WIND RELATIVE TO MEAN Version 1 3 17 28 va F E W
22. yWind team will regularly update the software in order to enhance its performance solve any minor bugs and to add extended functionalities In order to update your EasyWind software 1 Connect your reception unit to a power supply Connect your mini USB power cable to a power supply 2 Connect your reception unit to the internet Connect your ethernet cable from the reception unit to the to an internet network connection station or router Connected to the Internet Not connected to the Internet Version 1 3 25 26 EasyWind Software Manual Led lights Led lights A Ell 3 Connect your reception unit to your EasyWind WIFI Network GOTO your mobile device or PC WIFI connection manager and look for your EASYWIND WIFI network and click on CONNECT 4 Access EasyWind Software Interface GOTO your mobile device or pc web browser and type 192 168 42 1 5 Access the SYSTEM CONFIGURATION MENU 6 Open the UPDATE SOFTWARE TOGGLE ee G confi A a Wind conditions j Screen options aC Real Time Stats Weather conditions amp Boat conditions g View history Manage Identifiers System configuration WI FI settings o About EasyWind Advanced Don t touch 7 Click on the UPDATE BUTTON 8 Wait until you get a successful update message nfiguration Batura to version 91 Screen options Manage Identifiers WI FI settings Update Software Aake Gre sr hat Seton i co
Download Pdf Manuals
Related Search
Related Contents
MODE D`EMPLOI Espace Jeunes 2012 2013 JET 354169 Use and Care Manual 8kut 2 user manual 商標法 (PDF:322KB) Manuale d'uso e garanzia Operating instructions and guarantee スポンジフィルター 取扱説明書 95B68F918EE688B590E096BE8F912E786477 Olympia PK 51 Tourmaline Ceramic Styler Owner`s Manual Copyright © All rights reserved.
Failed to retrieve file