User`s Manual Endeavor 5 - 10KVA

image

Contents

1. MINUTE MAN POWER TECHNOLOGIES This product complies with the Restriction of certain Hazardous Substances ROHS Directive as conceived by the European Union committee 227222 1 in 2002 Products that meet the RoHS standard have been redesigned to remove the Endeavor 5 1 OKVA lead mercury cadmium hexavalent chromium where applicable As part of our efforts to maintain a healthy environment Para Systems has proactively adopted these Step Down Transfo rmer standards for our Minuteman brand products User s Manual Para Systems Inc 1455 Lemay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000473 R2 A NO PB WO N B MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES Table Of Contents Introduction Rear Panels Installation Operation Obtaining Service Specifications Limited Product Warranty Declaration of Conformity 14 16 17 18 19 Chapter 1 Introduction Thank you for purchasing this power protection product It has been designed and manufactured to provide many years of trouble free service Please read this manual before installing your Endeavor Series step down transformer ED XFR models ED5000RT XFR ED6000RT XFR ED8000RT XFR and ED10000RT XFR as it provides important information that should be followed during installation and maintenance of the ED XFR allowing you to corr
2. Frequency 50 60Hz Power Max 5KVA 5K Watts 10KVA 10K Watts Harmonic Distortion lt 3 Full Linear Load Efficiency gt 95 Full Load Waveform Type True Sine Wave Protection Operating Temperature max Resettable Circuit Breaker ENVIRONMENTAL 0 to 40 C 32 to 104 F Storage Temperature 15 to 50 C 5 to 122 F Operating Storage Humidity 0 95 Non Condensing Operating Elevation 0 to 2 000m 0 to 6 562 ft Storage Elevation 0 to 15 000m 0 to 49 213 ft Audible Noise at 1 m 3 ft Size Net LXWXH lt 50 dBA lt 60 dBA PHYSICAL 26 2 x 17 3 x 3 5 665 x 440 x 88 5 mm 25 9 x 17 3 x 5 14 659 x 440 x 130 6 mm Weight Net 82 7 lbs 35 5 Kgs 158 7 lbs 72 0 Kgs Size Shipping LXWXH 31 6 x 24 4 x 9 1 802 x 620 x 230 mm 30 7 x 23 6 x 10 9 780 x 600 x 276 mm Weight Shipping Safety and Approvals 123 5 lbs 56 0 Kgs 196 2 lbs 89 0 Kgs EGULATORY COMPLIANCE cTUVus Conforms to UL60950 1 2007 R12 11 CSA C22 2 No 60950 1 07 A1 2011 EMC Verification FCC Class B CE certified NOTE Specifications are subject to change without notice 17 Chapter 7 Limited Product Warranty Para Systems Inc Para Systems warrants this equipment when properly applied and operated within specified conditions against faulty materials or workmanship for a pe riod of three years from the
3. dust flammable gas or explosives m Leave adequate space at least 15cm around all sides of the unit for pr oper ventilation B Donot mount the unit with its front or rear panel facing down at any angle B Before usage you must allow the unit to adjust to room temperature 20 C 25 C or 68 F 77 F for at least one hour to avoid moisture cond ensing inside the unit WARNING This ED XFR contains potentially hazardous voltages Do not attempt to disassemble the unit This unit contains no user serviceable parts Repairs must be performed by QUALIFIED SERVICE PERSONNEL ONLY 2 BAA MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES CAUTION The ED5000RT XFR and ED6000RT XFR come with an attached 10 AWG input power cord Connect the input power cord to the output terminal block on the UPS The AC inputs of these Step Down Transformers are ONLY intended to be connected to the output of their respective UPS models Do not use extension cords adapter plugs or surge strips The installation of upstream and downstream protective devices is highly recom mended when the UPS system is connected to the mains and the load CAUTION The ED8000RT XFR and ED10000RT XFR come with an 6 AWG input power cable in the box The pins for the input and output cables are included Connect one end of the input power cable to the input terminal block on the ED XFR Connect the other end of the input power cable to the output terminal block on the UPS The AC in
4. Para Systems best judgment under the circumstances but it is used at the recipient s sole risk EXCEPT AS PROVIDED HEREIN PARA SYSTEMS MAKES NO WARRANTIES EX PRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT NESS FOR A PARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSI BILITY OF SUCH DAMAGE Specifically Para Systems is not liable for any costs such as labor for on site installation on site maintenance or on site service lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data cost of substitutes claims by third parties or otherwise The sole and exclusive remedy for breach of any warranty expressed or implied concerning Para Systems products and the only obligation of Para Systems hereunder shall be depot repair or replacement of defective equipment components or parts or at Para Systems option refund of the purchase price or substitution with an equivalent replacement product This warranty gives you specific legal rights and you may also have other rights which vary from state to state No employee salesman or agent of Para Systems is authorized to add to o
5. both 83 4A max 208V output Lc Ld 48 1A max 240V output La Lb 41 7A max NOTE Default voltages for the output receptacles are 120V and 208V 240V is available but only as a hardwire option at the output terminal block Chapter 4 Operation START UP IN THE NORMAL AC MODE The UPS must be connected to utility power and there must be an acceptable AC voltage present The Battery Pack s must be connected to the UPS and the DC breaker s on the rear panel of the Battery Pack s must be in the on position The input of the ED XFR must be connected to the output of the UPS The equipment is plugged into the output receptacles on the ED XFR 14 B MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES 1 Turn on the input breaker on the rear panel of the UPS The fans will turn on the AC normal icon will flash off on and the LCD will display bPS The UPS is now in the Bypass mode NOTE If there is a power interruption while the UPS is in the Bypass mode the load will not be backed up Turn on all of the Load breakers on the rear panel of the ED XFR Turn on the connected equipment one at a time Press and release the On Off Test Button after the first beep to turn the UPS on 5 The UPS will start up and perform a self diagnosis for approximately 10 seconds The UPS system is ready for normal opeartion See the UPS user s manual for more information a WN START UP IN THE BATTERY MODE The Battery Pack s must be connec
6. date of purchase For equipment sites within the United States and Canada this warranty covers depot repair or replacement of defective equip ment at the discretion of Para Systems Depot repair will be from the nearest authorized service center The customer pays for shipping the product to Para Systems Para Systems pays ground freight to ship the product back to the customer Replacement parts and warranty labor will be borne by Para Systems For equipment located outside of the United States and Canada Para Systems only covers faulty parts Para Systems products that are depot repaired or replaced pursuant to this warranty shall only be warranted for the unexpired portion of the warranty applying to the original product This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase The warranty shall be void if a the equipment is damaged by the customer is improp erly used is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications b the equipment is repaired or modified by anyone other than Para Systems or Para Systems approved personnel or c has been used in a manner contrary to the product s User s Manual or other written instructions Any technical advice furnished before or after delivery in regard to use or application of Para Systems equipment is furnished without charge and on the basis that it represents
7. for the repair Pack the unit in its original packaging If the original packaging is no lon ger available ask the Technical Support Technician about obtaining a new set It is important to pack the unit properly in order to avoid damage in transit Never use Styrofoam beads for a packing material a Include a letter with your name address day time phone number RMA number a copy of your original sales receipt and a brief desc ription of the problem Mark the RMA on the outside of all packages The factory cannot accept any package without the RMA marked on the outside Return the unit by insured prepaid carrier to Para Systems Inc MINUTEMAN UPS 1809 W Frankford Road Suite 150 Carrollton TX 75007 ATTN RMA B AA MINUTE EMAN UNINTERRUPTIBLE POWER SUPPLIES Chapter 6 Specifications Model Number SYSTEM SPECIFICATIONS ED5000RT XFR ED8000RT XFR ED6000RT XFR ED10000RT XFR Topology Number of Phase Isolation Step Down Tansformer Sine Wave INPUT Single 12W G Voltage Selectable 208 default 240VAC Freguency 50 60Hz Current Max 208VAC 24Amps 208VAC 49Amps 240VAC 21Amps 240VAC 42 5Amps Protection Resettable Circuit Breaker Connection Voltage Selectable Terminal Block Hardwire only Attached 2 open end 10 AWG power cord OUTPUT 208 amp 120VAC Default 240VAC Optional Voltage Regulation Nominal 3
8. output receptacle 1 L6 30R The input circuit breaker will trip in the event the load exceeds the ED XFR s power rating ED XFR s circuit breaker will trip in the event that the ED XFR becomes overheated Input terminal block 208V 240V is for connecting the input power cable that comes from the output terminal block of the UPS Output terminal block for optional hardwiring the load The available output voltages are 120V 208V 240V NOTE The two 120V outputs are ind ividual 5KVA outputs and they CANNOT be paralleled Chapter 3 Installation INSTALLATION PLACEMENT Cs I a Ss HE This ED XFR series is ONLY intended to be installed in an indoor temperature controlled environment that is free of conductive contaminants DO NOT oper ate the unit in extremely dusty and or unclean areas locations near heating devices water or excessive humidity or where the unit is exposed to direct sunlight Select a location which will provide good air circulation for the unit at all times Route power cords so they cannot be walked on or damaged The AC inputs of these Step Down Transformers are ONLY intended to be con nected to the output of their respective UPS models This ED XFR series is not intended for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 Operating Temperature Maximum 0 to 40 C 32 to 104 F Operating Elevation 0 t
9. N DO NOT USE THE MOUNTING BRACKETS TO LIFT THE STEP DOWN TRANSFORMER The mounting brackets are ONLY for securing the unit to the rack 3 UNINTERRUPTIBLE POWER SUPPLIES INNIS CAUTION To de energize the outputs of the ED XFR 1 Turn off the Load breakers on the rear panel of the ED XFR 2 Ifthe UPS is on press and release the On Off Test button after the sec ond beep 2 Turn off the input circuit breaker on the rear panel of the UPS 3 Turn off the DC breaker on the rear panel of the Battery Pack 4 Disconnect the UPS from the AC source NOTICE This equipment has been tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Sub part J of Part 15 of FCC Rules and the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference of the Canadian Depart ment of Communications These limits are designed to provide reasonable protection against such interference in a residential installation This equip ment generates and uses radio frequency and if not installed and used properly that is in strict accordance with the manufacturer s instructions this equip ment may cause interference to radio and television reception If this equip ment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one
10. UPTIBLE POWER SUPPLIES SVA c Connect the green wire labeled G on the input power cable to the ED XFR AC input terminal block ground terminal and secure 2 Connect the other end of the 6 AWG input power cable labeled TO UPS to the output terminal block on the UPS and secure a Connect the black wire labeled L on the input power cable to the UPS out put terminal block labeled L and secure b Connect the white wire labeled N on the input power cable to the UPS out put terminal block labeled N and secure c Connect the green wire labeled G on the input power cable to the UPS out put terminal block ground terminal and secure 3 Re installthe terminal block cover plate on the ED XFR 4 Before re installing the terminal block cover box on the UPS see the UPS us ers manual for the UPS input and output connections 5 Plug the equipment into the output receptacles on the rear panel of the ED XFR The ED8000RT XFR and ED10000RT XFR have a terminal block for ha rdwiring the output Refer to the figure below for the input output connections The pins for the output cable are included NOTE The two 120V outputs are individual 5KVA outputs and they CANNOT be paralleled Input Output terminal block for the ED8000RT XFR and ED10000RT XFR i D Lb Ld Lc La fore L 120 vac a 120 Vac 240 Vac 208 Vac 240 Vac L ac input LAC Output 120V outputs La N 50A max Lb N 50A max the combined total for
11. ectly set up your system for the maximum safety and performance Included is information on customer support and factory service if it is required If you experience a problem with the ED XFR please refer to Obtaining Service sec tion in this manual to collect enough information so that the Technical Support Department can rapidly assist you IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS CAUTION This ED XFR series is ONLY intended to be installed in an indoor temperature controlled environment that is free of conductive contaminants This ED XFR series is not intended for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Eguip ment ANSI NFPA 75 The AC inputs of these Step Down Transformers are ONLY intended to be connected to the output of their respective UPS models The ED XFR s input voltage setting must be the same as the UPS s output voltage setting CAUTION The maximum ambient operating temperature for this ED XFR series is 40 C 0 40 C for Ambient Operation EB The external vents and openings on the unit are provided for ventilation To ensure reliable operation of the unit and to protect the unit from over heating these vents and openings mustnot be blocked or covered Do not insert any object into any ofthe vents or openings that may hinder the ve ntilation B Install the unit in a well ventilated area away from excess moisture heat
12. ecure 4 Before re installing the terminal block cover box on the UPS see the UPS us ers manual for the UPS input and output connections 5 Set the input voltage select switch on the rear panel of the ED XFR to the appropr iate voltage 208V 240V NOTE The default setting is 208V The ED XFR s input voltage setting must be the same as the UPS s output voltage set ting 6 Plug the equipment into the output receptacles on the rear panel of the ED XFR NOTE Default voltages for the output receptacles are 120V and 208V Load 2 ouput receptacle can be changed to supply 240V but this change must be done at the factory ED8000RT XFR and ED10000RT XFR 1 Remove the terminal block cover plate from the rear panel of the ED XFR requires a phillips screwdriver Refer to the figure below for the input output connections for the ED8000RT XFR ED10000RT XFR Connect the end of the 6 AWG input power cable labeled TO XFR to the appropriate terminals on the AC input terminal block on the ED XFR and secure The pins for thein put cable are included a Connect the black wire labeled L1 L2 on the input power cable to the ED XFR AC input terminal block labeled L1 for 240V or L2 for 208V and se cure NOTE The ED XFR s input voltage setting must be the same as the UPS s output voltage setting b Connect the white wire labeled L3 on the input power cable to the ED XFR AC input terminal block labeled L3 and secure 13 UNINTERR
13. er s on the rear panel of the Battery Pack s oR OP 15 Chapter 5 Obtaining Service IF THE STEP DOWN TRANSFORMER REQUIRES SERVICE 1 2 5 6 16 Use the Troubleshooting section in the UPS user s manual to eliminate ob vious causes Verify there are no tripped circuit breakers A tripped circuit breaker is the most common issue Call your dealer for assistance If you cannot reach your dealer or if they cannot resolve the issue call or fax the Technical Support department at the following numbers Voice phone 972 446 7363 FAX line 972 446 9011 or visit our Web site at www minutemanups com the Discussion Board Before calling the Technical Support Department have the follow ing information available a Contact name and address b Where and when the unit was purchased c All of the model information about your unit d The serial number of your unit e Any information on the failure including LEDs that may be illuminat ed or error codes displayed A description of the protected equipment including model numbers if possible g Atechnician will ask you for the above information and if possible help solve the issue over the phone In the event that the unit requires factory service the technician will issue you a Return Material Autho rization Number RMA h Ifthe unit is under warranty the repairs will be done at no charge If the unit is not under warranty there will be a charge
14. front panel from the ED XFR On the backside of the front panel push the name plate panel outwards the panel will pop out Rotate the name plate panel counter clockwise so that it reads in the upright position Re install the front panel on the ED XFR EE REE Sy ED 10 B MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES CONNECTING THE STEP DOWN TRANSFORMER TO THE UPS WARNING Qualified Service Personnel ONLY must perform the Installa tion and Servicing of these ED XFR 1 Before connecting to the input output terminals read all of the Cautions and Warning then observe the following a Ensure that the UPS is turned off and not connected to the AC sour ce or the battery source before any connections are made b Calculate the power consumption of the load to ensure that an over load condition does not occur c Ensure that the terminal block screws are secured after connecting the input output wires The terminal block screws should be torque to 18 2Kgf cm requires a 3 16 flat head screwdriver d Ensure that the ED XFR and the UPS are properly grounded 2 The input power for the ED XFR must be single phase in accordance with its rating label and the specifications in this manual The ED XFR s input voltage setting must be the same as the UPS s output voltage setting NOTE The AC inputs of these Step Down Transformers are ONLY intend ed to be connected to the output of their respective UPS models T
15. g the unit to the rack 1 Attach the rackmount brackets to the mounting holes on the side panel of the ED XFR as shown below 2 Follow steps 1 through 4 to install the ED XFR into the Rail kit See the figure below Step 1 Adjust the length of the rail according to the rack Step 2 Securely tighten the wing nuts Step 3 Secure the rail to the rack with the enclosed screws Step 4 Slide the ED XFR onto the rail and secure to the rack with the enclosed screws f OOOOOO 70 OO O OOGSOOO OOOOOO NI UNINTERRUPTIBLE SUPPLIES JAA TOWER CONFIGURATION The tower configuration allows the user to install the ED XFR in the up right position The tower stands are provided with the UPS The tower stand ex tenders are provided with the ED XFR WARNING Use two or more people when installing the ED XFR USE CAUTION The ED XFR is extremely heavy Use the appropriate number of personnel when installing the UPS system 1 Once the location of the ED XFR has been determined place the tower stands in the desired location WARNING The ED XFR must be installed in the proper up right position Once the ED XFR is placed in the tower stands the vent holes on the side panels must be facing upwards to provide proper ventilation 2 Slide the ED XFR into the tower stands Make sure that the ED XFR is stable 3 The name plate panel can be rotated to read in the up right position Rem ove the
16. he ED5000RT XFR and ED6000RT XFR come with an attached 10 AWG input power cord Connect the input power cord to the output terminal block on the UPS The AC inputs of these Step Down Transformers are ONLY intended to be connected to the output of their respective UPS models Do not use extension cords adapter plugs or surge strips The installation of up stream and downstream protective devices is highly recommended when the UPS system is connected to the mains and the load Connect to Utility BEER oe EES 9 E lt a Connect Load 1 MIN AN Nye UNINTERRUPTIBLE POWER SUPPLIES The ED8000RT XFR and ED10000RT XFR come with an 6 AWG input power cable in the box The pins for the input cable are included Connect one end of the input power cable to the input terminal block on the ED XFR Connect the other end of the input power cable to the output terminal block on the UPS The AC inputs of these Step Down Transformers are ONLY intended to be connected to the output of their respective UPS models Do not use extension cords adapter plugs or surge strips The installation of upstream and down stream protective devices is highly recommended when the UPS system is connected to the mains and the load Connect to Utility lt a Connect Load INPUT OUTPUT CONNECTIONS WARNING Qualified Service Personnel ONLY must perform the Installa tion and Servicing of these ED XFR 1 Remove the terminal bloc
17. he package is deemed to be not shippable contents shall be promptly collected segregated and either the consignor or consignee contacted LIFE SUPPORT POLICY As a general policy Para Systems does not recommend the use of any of our products in life support applications where failure or malfunction of the product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness We do not recommend the use of any of our products in direct patient care We will not knowingly sell our prod ucts for use in such applications unless it receives in writing assurances satis factory to us that a the risks of injury or damage have been minimized b the customer assumes all such risks and c our liability is adequately protected under the circumstances Examples of devices considered to be life support devices are neonatal oxygen analyzers nerve stimulators whether used for anesthesia pain relief or other purposes auto transfusion devices blood pumps defibrillators arrhythmia detectors and alarms pacemakers hemodialysis systems peritoneal dialysis systems neonatal ventilator incubators ventilators for both adults and infants anesthesia ventilators and infusion pumps as well as any other devices desig nated as critical by the United States FDA COPYRIGHT 2014 BY PARA SYSTEMS INC All Rights Reserved All rights of this User Manual Manual including bu
18. in the event the load exceeds the power rating Load 2 208V output receptacle 1 L6 20R NOTE The default output voltage is 208V 240V is available but must be configured at the factory The Load 1 circuit breaker will trip inthe eventthe load exceeds the power rating Load 1 208V output receptacle 1 L6 30R The input circuit breaker will trip in the event the load exceeds the ED XFR s power rating The input power cord is for connecting to the output terminal block on the UPS ED XFR s circuit breaker will trip in the event that the ED XFR becomes overheated Input voltage selection switch 208 240V The default setting is 208V B AA MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES ED8000RT XFR ED10000RT XFR 10 11 12 10 5 1 A o TOP REAR OF UNIT Lv Beer Wer j dede o t 4 e WIST A Sa ee dd E We rn The Load 4 circuit breaker will trip in the event the load exceeds the power rating Load 4 120V output receptacles 4 5 15 20R The Load 2 circuit breaker will trip in the event the load exceeds the power rating Load 2 120V output receptacles 4 5 15 20R The Load 2 circuit breaker will trip in the event the load exceeds the power rating Load 3 208V output receptacle 1 L6 20R The Load 1 circuit breaker will trip in the event the load exceeds the power rating Load 1 208V
19. k cover box from the rear panel of the UPS re quires a phillips screwdriver Refer to the figure below for the input out put connections for the UPS See the UPS user s manual for connecting the UPS s input and output cables OUTPUT INPUT 230Vac 50 60Hz 230Vac 50 60Hz hdd 12 B MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES 2 Input Output cable selection Temperature Rating 5 6KVA 8 10KVA 60 C 75 C 10 AWG Cu 6 AWG Cu In accordance with National Electrical Code NEC install suitable con duit and bushing NOTE Use copper wire only 3 Before connecting to the input output terminals read all of the Cautions and Warning The AC inputs of these Step Down Transformers are ONLY intend ed to be connected to the output of their respective UPS models NOTE The ED XFR s input voltage setting must be the same as the UPS s output voltage setting ED5000RT XFR and ED6000RT XFR See the UPS users manual for UPS input and output connections Connect the attached 10 AWG input power cord on the ED XFR to the output terminal block on the UPS 1 Connect the black wire labeled L on the attached input power cord to the UPS output terminal block labeled L and secure 2 Connect the white wire labeled N on the attached input power cord to the UPS output terminal block labeled N and secure 3 Connect the green wire labeled G on the attached input power cord to the UPS output terminal block ground terminal and s
20. o 2 000m 0 to 6 562 ft Operating and Storage Relative Humidity 95 non condensing Storage Temperature 15 to 50 C 5 to 122 F Storage Elevation 0 to 15 000m 0 to 49 213 ft INSTALLATION Be sure to read the installation placement and all the cautions before installing the ED XFR Place the unit in the final desired location and complete the rest of the installation procedure See the Rackmount Configuration to install the unit into the rack USE CAUTION The ED XFR UPS and Battery Pack are extremely heavy Use the appropriate number of personnel when installing the UPS system CAUTION DO NOT USE THE MOUNTING BRACKETS TO LIFT THE STEP DOWN TRANSFORMER The mounting brackets are ONLY for securing the unit to the rack NOTE The ED XFR UPS and Battery Pack are extremely heavy Use the following placement when rack mounting 1 The ED XFR should be installed close to the bottom of the rack 2 Then install the Battery Pack right above the ED XFR 3 Then install the UPS right above the Battery Pack 8 B AA MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES RACKMOUNT CONFIGURATION Use the included rackmount brackets and screws to mount the ED XFR ina rack by following the steps below USE CAUTION The ED XFR is extremely heavy Usethe appropriate number of personnel when installing the UPS system CAUTION DO NOT USE THE MOUNTING BRACKETS TO LIFT THE STEP DOWN TRANSFORMER The mounting brackets are ONLY for se curin
21. or more of the following measures M Re orient the receiving antenna Relocate the computer with respect to the receiver Move the computer away from the receiver Plug the computer into a different outlet so that the computer and receiver are on different branch circuits m Shielded communications interface cables must be used with this product WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RECIEVING INSPECTION Once you receive the product it should be visually inspected for damage that may have occurred in shipping Immediately notify the carrier and place of purchase if any damage is found Warranty claims for damage caused by the carrier will not be honored by the manufacturer The packing materials that the product was shipped in were carefully designed to minimize any shipping damage In the unlikely case that the product needs to be returned to the manufacturer use the original packing material Since the manufacturer is not responsible for shipping damage incurred when the product is returned the original packing material is inexpensive insurance PLEASE SAVE THE PACKING MATERIALS B AA MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES AN CAUTION IF DAMAGED Packages crushed punctured or tom such that contents are revealed should be set aside in an isolated area and be inspected by a qualified person If t
22. puts of these Step Down Transformers are ONLY intended to be connected to the output of their respective UPS models Do not use extension cords adapter plugs or surge strips The installation of upstream and downstream protective devices is highly recom mended when the UPS system is connected to the mains and the load CAUTION To reduce the risk of electrical shock with the installation of this unit and the connected equipment the user must ensure that the ED XFR is properly grounded due to a possible risk of AC current leakage WARNING Qualified Service Personnel ONLY must perform the Installa tion and Servicing of these ED XFR MINUTEMAN accepts no liabilities and is not limited to injury to the Service Personnel or damages to the Step Down Transformer the UPS the Battery Pack or the connected equipment caused by the incorrect installation or servicing of the UPS system These ED XFR MUST be operated with their respective UPS models see the table below ED XFR ED5000RT XFR ED8000RT XFR ED6000RT XFR ED10000RT XFR UPS ED5000RT CU ED8000RT CU ED6000RT CU ED10000RT CU WARNING When using these Step Down Transformers with their respective UPS models the load capacity of the UPS MUST be derated as follows ED5000RT CU ED6000RT CU ED8000RT CU ED10000RT CU EDS000RT XFR ED6000RT XFR ED8000RT XFR ED10000RT XFR 4556VA 5556VA 6889VA 8889VA 4100Watts 5000Watts 6200Watts 8000Watts CAUTIO
23. r vary the terms of this warranty 18 A1 DECLARATION OF CONFORMITY Application of Council Directive s 2004 108 EC Standard s to which Conformity is declared EN 50091 2 1995 Class A IEC61000 4 2 level4 IEC61000 4 3 level3 IEC61000 4 4 level4 IEC61000 4 5 level4 IEC61000 4 6 level3 IEC61000 4 8 level3 IEC 62040 2 2005 IEEE C62 41 Category Al Manufacturer s Name Para Systems Inc MINUTEMAN UPS Manufacturer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No ED5000RT XFR ED6000RT XFR ED8000RT XFR ED10000RT XFR Year of Manufacture Beginning April 1 2014 hereby declare that the equipment specified above conforms to the above Directive s Robert Calhoun Manager Engineering Name Position Place Carrollton Texas USA Date April 1 2014 19 MINUTEEEMAN A A AA MINUTEEEMAN UNINTERRUPTIBLE POWER SUPPLIES UNINTERRUPTIBLE POWER SUPPLIES Notes Notes 200 ee TTT IT
24. t not limited to the content information and figures are solely owned and reserved by Para Systems Inc Para Systems The Manual can only be applied to the operation or the use of this product Any disposition duplication dissemi nation reproduction modification translation extraction or usage of this Manual in whole or in part is prohibited without the prior written permission of Para Systems Given that Para Systems will continuously improve and develop the product changes may be made to the information in this Manual at any time without obligation to notify any person of such revision or changes Para Systems will make all possible efforts to secure the accuracy and the integrity of this Manual Para Systems disclaims any kinds or forms of warranty guar antee or undertaking either expressly or implicitly including but not limited to the completeness faultlessness accuracy non infringement merchantability or fitness for a particular purpose of the Manual UNINTERRUPTIBLE Why ER SUPPLIES Chapter 2 Rear Panels ED5000RT XFR ED6000RT XFR 10 11 12 The Load 4 circuit breaker will trip in the event the load exceeds the power rating Load 4 120V output receptacles 3 5 15 20R The Load 3 circuit breaker will trip in the event the load exceeds the power rating Load 3 120V output receptacles 3 5 15 20R The Load 2 circuit breaker will trip
25. ted to the UPS and the DC breaker s on the rear panel of the Battery Pack s must be in the on position The input of the ED XFR must be connected to the output of the UPS The equipment must plugged into the output receptacles on the ED XFR Turn on the input breaker on the rear panel of the UPS a Press and release the On Off Test Button after the first beep to turn the UPS on 3 The fans will turn on then the UPS will start up and perform a self diagno sis for approximately 10 seconds 4 Turn on all of the Load breakers on the rear panel of the ED XFR 5 Turn on the connected equipment one at a time See the UPS user s ma nual for more information TURNING OFF THE STEP DOWN TRANSFORMER IN THE NORMAL AC MODE 1 Press and release the On Off Test Button on the front panel of the UPS aft er the second beep to transfer the UPS to the Bypass mode Turnoffallofthe connected eguipment Turn off all of the Load breakers on the rear panel of the ED XFR Turn off the input breaker on the rear panel of the UPS Turn off the DC breaker s on the rear panel of the Battery Pack s TURNING OFF THE STEP DOWN TRANSFORMER IN THE BATTERY MODE 1 Turn off all of the connected equipment 2 Turn off all of the Load breakers on the rear panel of the ED XFR 3 Press and release the On Off Test Button after the second beep to turn the UPS off 4 Turn off the input breaker on the rear panel of the UPS 5 Turn off the DC break