Ethernet Communications Module

image

Contents

1. LX xxx also covers RCS116 Color Touch OCS e g OCSxxx MAN0465 OCS Operator Control Station e g OCS1xx 2xx Graphic OCS250 MAN0227 Remote Control Station e g RCS2x0 MiniOCS e g HE5000CSxxx HE500RCSxxx MANO305 Other Useful References MANO799 MAN0313 MAN0347 Information is subject to change without notice SmartStack is a trademark of Horner APG LLC PAGE 8 10 NOV 2006 MANO0741 04 ETN200 ETN300 7 TECHNICAL SUPPORT For assistance and manual up dates contact Technical Support at the following locations North America Europe 317 916 4274 353 21 4321 266 www heapg com www horner apg com Information is subject to change without notice SmartStack is a trademark of Horner APG LLC
2. and shock hazards WARNING In the event of repeated failure do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse WARNING Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install adjust operate or service this equipment Read and understand this manual and other applicable manuals in their entirety before proceeding Failure to observe this precaution could result in severe bodily injury or loss of life Information is subject to change without notice SmartStack is a trademark of Horner APG LLC PAGE 6 10 NOV 2006 MANO0741 04 ETN200 ETN300 For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances refer to the hardware manual of the controller you are using See the Additional References section in this document All applicable codes and standards need to be followed in the installation of this product For I O wiring discrete use the following wire type or equivalent Belden 9918 18 AWG or larger Adhere to the following safety precautions whenever any type of connection is made to the module Connect the green safety earth ground first before making any other connections When connecting to electric circuits or pulse initiating equipment open their related breakers Do not make connections to liv
3. MANO0741 04 10 NOV 2006 PAGE 1 ETN200 ETN300 Ethernet O Communications Module nart HE800ETN200 HE800ETN300 Si HORNER HE ETN200 HE ETN300 APG Denotes plastic case This product has a detailed supplement SUP0740 1 DESCRIPTION The SmartStack Ethernet Module ETN200 ETN300 gives the Horner OCS family of controllers the capability to communicate over Ethernet Some controller models such as OCS451 OCS551 and OCS651 have built in ETN200 ETN300 capabilities while other models such as OCS110 OCS210 OCS250 and RCS250 require a user installed ETN200 ETN300 SmartStack module In either case the ETN200 ETN300 supports the following application protocols Table 1 Protocol Features Protocol Feature Protocol Feature Description ETN200 ETN300 ICMP Ping Internet Control Message Protocol EGD Peer GE Fanuc Ethernet Global Data SRTP Server GE Fanuc Service Request Transfer Protocol Modbus TCP Slave Modbus over Ethernet CsCAN TCP Server Horner APG CsCAN over Ethernet Ethernet IP Server ODVA CIP over Ethernet gt FTP Server File Transfer Protocol gt HTTP Server HyperText Transfer Protocol Web Server Half Full Duplex Auto Negotiated Ethernet Mode 10 100 MHz Auto Negotiated Ethernet Speed Extended Registers Access to R2049 R9999 FTP amp HTTP protocols are supported only by OCS Models with built in Ethernet and Compact Flash such as OCS451 OCS551 OCS651 NX221 NX251
4. QX451 QX551 and QX651 Lje jejejejejeje j2 j2 Lje je jejejejejeje j2 2 Information is subject to change without notice SmartStack is a trademark of Horner APG LLC PAGE 2 2 SPECIFICATIONS 10 NOV 2006 MANO741 04 ETN200 ETN300 Table 2 ETN 200 ETN 300 Specifications Ethernet Connector Type General 10 BaseT Ethernet 10 MHz Ethernet Speeds 100 BaseTx Fast Ethernet 100 MHz Ethernet Modes Half or Full Duplex Ethernet Auto Negotiation Both 10 100 MHz and Half Full Duplex Shielded RJ 45 Ethernet Cable Type Recommendation CATS5 or better UTP Application Protocols ICMP Ping Only CsCAN TCP Server Maximum Connections 8 EGD Ethernet Global Data SRTP Server Maximum Data Bytes per Exchange 1 400 Maximum Exchanges 127 Maximum Connections 16 Modbus TCP Slave Maximum Connections 16 Ethernet IP Server Maximum Connections 2 FTP Server Maximum Connections 4 HTTP Server Information is subject to change without notice Maximum Connections 1 SmartStack is a trademark of Horner APG LLC MANO741 04 10 NOV 2006 PAGE 3 ETN200 ETN300 Ethernet Module configuration is done through Cscape Programming Software Figure 1 illustrates an example of a network containing ETN200 and ETN300 Ethernet Modules Figure 1 Example of an Ethernet Network Information is subject to change without notice Sm
5. artStack is a trademark of Horner APG LLC PAGE 4 10 NOV 2006 MANO741 04 ETN200 ETN300 3 CONNECTORS Note If using a controller with built in Ethernet refer to the controller s user manual See Additional References in this document Ethernet Connector Hi Close up of B B Ethernet Connection E z 1000000 l OCS Bottom View Figure 2 Ethernet Connector on the ETN SmartStack Module Note The ETN200 ETN300 must be installed in the first slot 4 ETHERNET SYSTEM REQUIREMENTS AND INTEROPERABILITY e PC running Cscape Programming Software Version 7 0c or later for configuration e OCS controller with built in or user installed ETN200 or ETN300 Ethernet Module e FTP amp HTTP protocols supported only by OCS Models with built in Ethernet and Compact Flash The server protocols supported by the ETN200 and ETN300 SmartStack Ethernet Modules have been tested for interoperability with Cscape and several 3rd party client software packages as shown in the following Table Table 3 Ethernet Module Server Protocol Interoperability Client Software Package Ethernet Module Server Protocol Name Version CsCAN SRTP Modbus EIP FTP HTTP Cscape Programming Software 7 0c NI GE Proficy View 5 50 3655 V GE Fanuc Cimplicity HMI 3 2 N GE Fanuc Cimplicity PE 28 y J KEPware OPC DDE Server 4 84 227 V V Pyramid EIP Scann
6. e power lines Make connections to the module first then connect to the circuit to be monitored Route power wires in a safe manner in accordance with good practice and local codes Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits Ensure hands shoes and floor are dry before making any connection to a power line Make sure the unit is turned OFF before making connection to terminals Make sure all circuits are de energized before making connections Before each use inspect all cables for breaks or cracks in the insulation Replace immediately if defective Information is subject to change without notice SmartStack is a trademark of Horner APG LLC MANO0741 04 10 NOV 2006 PAGE 7 ETN200 ETN300 6 ADDITIONAL REFERENCES The following information serves as a general listing of Horner controller products and other references of interest and their corresponding manual numbers Visit our website listed in the Technical Support section to obtain user documentation and updates Note This list is not intended for users to determine which products are appropriate for their application controller products differ in the features that they support If assistance is required see the Technical Support section in this document Controller Manual Number XLE Series e g HE XExxx MANO805 QX Series e g HE QXxxx MANO798 NX Series e g HE NXxxx LX Series e g
7. er Demo 3 51 y 5 50 4522 NI N Microsoft Internet Explorer 6 0 2900 q F SmartFTP 1 5 990 NI Mozilla Firefox 1 0 7 N When selecting the PLC Access Driver for SRTP mode using Proficy View software be sure to select GE Fanuc TCP IP Information is subject to change without notice SmartStack is a trademark of Horner APG LLC MANO0741 04 10 NOV 2006 PAGE 5 ETN200 ETN300 5 INSTALLATION SAFETY Warning Remove power from the OCS controller CAN port and any peripheral equipment connected to this local system before adding or replacing this or any module Use the following wire type or equivalent e Belden 8917 e 16AWG or larger For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances refer to the hardware manual of the controller you are using See the Additional References section in this document When found on the product the following symbols specify AN Warning Consult user documentation A Warning Electrical Shock Hazard WARNING To avoid the risk of electric shock or burns always connect the safety or earth ground before making any other connections WARNING To reduce the risk of fire electrical shock or physical injury it is strongly recommended to fuse the voltage measurement inputs Be sure to locate fuses as close to the source as possible WARNING Replace fuse with the same type and rating to provide protection against risk of fire