Home
CCN Driver User Manual
Contents
1. Database Palette saba H E CenNetwork E evict CenTableGroup C new 1 Edit 88 Discover O Cancel d ada match Figure 25 Adding Points to station database NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 14 Ccn Alarm History Manager Con alarm history manager is the default view for a alarm history table It is as follows Niagara Workbentl STE File Edit Search Bookmarks Tools Window Manager Help e 0D 8 e L D Y hA A x Gu e o My Host tridium2 censtation Station censtation Config Drivers c2 CenNetwork CC640002 e Points e AlarmHistory FT ALAMHIST A Cen Alarm History Manager Nav O Cen Alarm History SZ D O My Network 7 Discovered El My Host tridium2 censtation Alarm Text Summary de My Modules CC6400 0 2 ALERT O at 31 Dec 02 9 32 AM IST 13 Feb 03 12 00 AM IST El My File System CC6400 0 2 ALERT O at 31 Dec 02 7 26 PM IST 06 Nov 02 12 00 AM IST Platform CC6400 0 2 ALERT 0 at 31 Dec 02 7 25 PM IST 06 Nov 02 12 00 AM IST K station censtation CC6400 0 2 ALERT 0 at 31 Dec 02 12 20 PM IST 08 Oct 02 12 00 AM IST E Config CC6400 0 2 ALERT O at 31 Dec 02 10 24 AM IST 02 Jul 02 12 00 AM IST services CC6400 0 2 ALERT 0 at 31 Dec 02 10 14 AM IST 26 Jun 02 12 00 AM IST SB Drivers CC6400 0 2 ALERT 0 at 31 Dec 02 2 10 PM I
2. Nav Driver Manager Name Type Status Enabled Fault Cause 5 NiagaraNetwork Niagara Network ok true a My Host ie10dtx66qvb1s CcnNetwork Cen Network ok true 8 My Modules E My File System Platform Kl station censtation B Config T B Services aen Co NiagaraNetwork El CenNetwork E Files ZR History 199 63 42 169 199 63 42 183 X Palette S K 0c 88 CenNetwork ae CenDevice E CenTableGroup Figure1 CcnNetwork from Driver Manager View NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help e gt 4 0 ATAS HBB HAA car p eo Lal My Host ie1Odtx66qvb1s gie My Modules CON module palette C3 CcnNetwork LE 6 my Network Bi my Host ie LOdtx66gvbis gh My Modules E My File System Discovered Platform A Station censtation B Config xd Services CB Drivers ZB NiagaraNetwork E Files ZR History 199 63 42 169 199 63 42 183 Name Database Name Bus No_ Elel Palette snoa kl SEREA L ConDevice CenTableGroup Figure2 CcnNetwork from palette 7 1 CCN Network status notes As with most other drivers the status of a CcnNetwork is either the normal ok or less typical fault fault mi
3. EB My Modules Table Type String E My File System RTCCNOOC 16 UserConfiguration Platform ELEPHANT 16 UserConfiguration Ki Station censtation TIGER 16 UserConfiguration E Config ADAPTOLC 16 UserConfiguration services HWPO1_32 17 StatusDisplay lt p Drivers HWP33 64 17 StatusDisplay CB NiagaraNetwork SWP65 96 17 StatusDisplay i confer work RTCCNOON 18 Maintenance ba C Sourco To LIDPROOM 18 Maintenance E ema DBSTATUS 18 Maintenance Necro AE SAREE STPR_01M 18 Maintenance ES Files ADAPTO1M 18 Maintenance x 20 UserConfiguration Palette 20 UserConfiquration Database Name 8 CenNetwork amp ES E CenTableGroup Figure 14 CcnTable Discovery NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help e gt D dep s HEB xbabx c noBiao ss y Nav a o Cen Add Tables D E L My Network Te E My File System Table Type Table Type String Platform RTCCNOOC 16 llicarre KA Station censtation ELEPHANT 16 Ctri A lian E Config TIGER 16 ach Ce E Z services art E Select all ion Ef Drivers HWPO1_32 17 StatusDisplay gie NiagaraNetwork EEE Sl SWPE5 96 EN RTCCNOON ee oe LIDPROOM BI nz _ rne aoe ae ou tly History ADAPTOIM abedefg h Palette CMAIUZ2D 20 UserConfiquration S
4. A Station censtation B config EP services Drivers Y cut CE CB NiagaraNetwork Da Copy ee eo a B Paste Ctrl Q Alarm Source Info EP Paste Special Points E Duplicate zz 2 UserConfiguration Delete Delete StatusDisplay E E Hweat_s2 58 Find Ges Link Mark e Link From SFYFD_ST Link To 5A_ALGO baa WRSYS_ST J Rename Ctl R PMP_sPD Bt Reorder 89 Maintenance 83 SetPoints d AlarmHistor Palette S CenNetwork CenDevice E CenTableGroup Niagara Workbenci File Edit Search Bookmarks Tools Window Manager Help Figure 37 overriding a value to the point Ji 2 a o g My Host tridium2 censtation Station censtation DasBbls BlxhBbx Config Sra Dri O CenNetwork E CC6400_0_2 HBO ss f Points EB StatusDisplay Cen Point List Manager El My Host tridium2 censtation GB My Modules E My File System Platform R Station censtation B config D Services lt p Drivers CB NiagaraNetwork 85 CenNetwork Ge cces00 0 2 amp Alarm Source Info Points 83 UserConfiguration GB StatusDisplay EI Hweo1_92 Q Hwe3 SFYFD_ST sa ALGO WRSYS_ST PMP_sPD Maintenance SetPoints E AlarmHisto Palette a D Gcn 7 ei E S CenNetwork V CenDevice CenTableGroup NIAGARA
5. Technical Document NiagaraMX 3 x CCN Driver User Guide iagdra NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 VOD OCU Cis edi nad aa is 4 I he CON NetWork TT 4 A A SE a a ne 4 Cen Sado EE 4 Zo Niagara Ee LEE 5 ER QUICK E EE 5 K Opetatine Wades it CAN DEE 6 Configure Gen Nei work EE 6 5 1 Add a Con Network sisi n tenant 6 2 2 Discover and ada RTE 6 OCEN AACHEN 7 CENSO sie son DU ES ARENDT da IT TR ARA EIA E a E och coma nad 8 K N G Network status Olesa is 9 7 2 GCN Network monitor notes gece EERSTEN sais 9 EE A A ga OU nee EET 9 T A CEN Network TE TEE 9 8 Con Device Manara 13 Den DOVICE axe cet A teas ates CN aoe a ans es tana a ede A ae 16 Cen Device Status e ips doa aes Ti en cn 17 OD ASCH Device Properhes ias 17 9 3 CcnDevice property sheet for Status Properties esse ee eee ee ee eee 19 94 ConDevice Property Sh et suite 20 9 5 Table Group selection Properties so asia ads atado DISSE do 20 JG CHDENICE Actions eeh A A nee eds ete 21 10 Con Table Manager ii ita 22 EE RE 26 11 Cen Fable Comb Our qui Onn icp coca cea eee el ae 26 111 2 Con Fable Properties isos n a RE RE 27 LS Cem aC ads 30 LEE eegen 30 US eI A anager T 30 13 Cen Data Point List Manaos segs pus tege Taga iii 31 14 Cen Alarm History Manager 34 15 Con Fid Point List Mantra ts 34 16 Cn Time Sehudule Manager EE 36 17 Con Pots cia 38 17 1Creating and Configuring the CcnObject ss 39 et Propertie Serao akira ad aang
6. ConNetwork Con Network 1 Status 1 Enabled O true 7 3 O Faut Cause E Health Ok 21 Oct 09 1 49 PM GMT 05 30 ai D Alarm Source Info Alarm Source Info 1 E Monitor Ping Monitor Ya Tuning Policies Tuning Policy Map Bo Poll Scheduler Basic Poll Scheduler J Retry Count o 24 _ Response Timeout _ Clear Bridge List _ Create Tables 3 Auto Create Points O false Le Bridges Ccn Bridges List 1 Learn Status fae T L First Bus No fo fo 288 3 Last Bus No fo J fo 289 1 Low Elem No fo J fo 289 1 High Elem No 0 239 O Device Learn Count ED _1 O Display Metric O false 7 Figure 3 Ccn Network View Unsolicited Receive Handler Ccn Unsolicited Receive _1 Alarm Acknowledger 3 Broadcast Acknowledger 3 Time Syne Stat 3 Time Broadcaster O fase gt 3 Time Sync Display Dots 3 Bus Address o o 239 J Elem Address 1 239 3 Low Level Debug O fase y 3 Low Level Debug Mask o 0 max 3 Comm Port 3 Host Baud Rate lBaud9600 Le Figure 4 CcnNetwork Property sheet 8 Ccn Device Manager The Cen Device Manager is the default view when you double click on a Ccn Network in the Nav tree This manager view provides a quick and easy way to display and learn Ccn devices that are on the Cen network The Cen Device Manager is the default view for any Cen Network container The Ccn Device Manager is a table based vie
7. s or CenPocTables TableListManager creation process NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Alternatively a CcnTable may be added to an existing station using the copy and paste method To do so From Ccn Table Manager add a table to table group by using new button This will add the CcnTable to the CcnDevice or CcnPocTable set the CcnTable tableType and tablelnstance properties to the actual type and instance of the table to be shadowed must enter these in decimal not hex if table type is set to 501H for Fid IO points be sure and set the instance to 1 if the table type is CcnDataTable or CcnDataTableWithTimeSchedule user must also set the blockNumber doa fetch command on the Menu bar under commands or at the bottom of the view will retrieve additional needed table information and build the pointList Note Table name SPSCHPOC will not support manual addition of table and fetching 11 2 CcnTable Properties Table Type Table s table type The valid values are Pic tables 16 10H 17 11H 18 12H 19 13H 23 17H Poc tables 20 14H 21 15H 22 16H 24 18H AH tables 67 43H Data tables gt 127 tableTypeString The table s table group type tablelnstance Table s table instance number tableNumber Table s unique table number tableName Table s 8 character table name This is the
8. AX CCN Driver User Manual Database SFVFD_ST Supply Fan VFD Status O SA ALGO Supply Air VFD Algo O WRSYS_ST Water System Status OFF ok def 0 0 ok def OFF ok O def Figure 38 after overriding 4 objects Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Niagara Workbenci Lely File Edit Search Bookmarks Tools Window Manager Help se 0 D ATA S CoB X DR RHEMO ss My Host tridium2 ccnstation Station ccnstation Config a Drivers CO CenNetwork Ercceso 02 Points e StatusDisplay Con Point List Manager Nav Database 4 objects DO IBe TS Name Description Joe funitsEnum Field Status Forcetevel FieldName fEl SFVFD_ST Supply Fan VFD Status Off ok def SFVFD ST El My Host tridium2 censtation O sa ALGO Supply Air YFD Algo 0 0 ok O def K SA ALGO 8 My Modules O WRSYS_ST Water System Status Off ok def WRSYS_ST E My File System SNE SO Secondary VFD Pump Speed Ce Platform Views BA Station ccnstation Actions Override B Config Ars Services Nen E Drivers Y cut i ZB NiagaraNetwork Da Copy Abe 85 CenNetwork Ge cc6400_0 2 B Paste lan D Alarm Source Info EB Paste Special Points Gy Duplicate cule E UserConfiguration X Delete Delete StatusDisplay ESET po HWPO1_32 BA Find Det Link Mark NS Link From SFVFD_ST link Ta 5
9. CcnDevice s property sheet 9 3 CcnDevice property sheet for Status Properties L CenDevice_0_2 Cen Device _ Status 30 pi 30 Faut Cause Health Fail 19 Dec 08 1 30 PM GMT 05 30 failed no re Figure 10 CcnDevice Property sheet NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver User Manual 9 4 CcnDevice Property Sheet _ Bus No _ Elem No _ Device Name _ Pic Type _ Application Version _ Device Status _ Device Description _ Location _ Part No _ Model No _ Serial No _ Reference No _ Platform No _ Os Version _ Device Type _ Primary Baud Rate _ Secondary Baud Rate _ Max Table Number _ Table Learn Count _ Learn Status _ Table Create Count _ Debug On _ Debug Discovery On _ Device Time _ Device Ping Status _ Cen Device Enabled _ E Enhanced Version KT E Ip C6400 4cc 6 pun n Line omfort Controller EPP 130124 07 400 ersion 1 6 Non Bridge Baud9600 A Baud9600 Kal Idle Ofase v 9 Dec 2008 05 33 PM GMT 05 30 succeeded and parsed date from ping mess O true il Figure 11 CcnDevice Property sheet 9 5 Table Group selection Properties User can select the type of table group he wants to discover The Table groups which are selected as t
10. Description out units Enum Field Status ForceLevel FieldName IE O TIMEBCST Time Broadcast Enable Disable ok def TIMEBCST Platform O reen Dayight Savings oftdepod DAS R Station censtation DLSTRMON Start Month 10 ok def DLSTRMON B Config DLSTRDOW Start Day Of Week 3 ok def DLSTRDOW GP Services DLSTRWK Start Week 5 ok def DLSTRWK Drivers DLSTRTIM Start Time 03 45 ok def DLSTRTIM SB NiagaraNetwork O DLSTRADY Sat Advance 50 0 ok def min DLSTRADY amp CenNetwork DLSTPMON Stop Month 12 ok def DLSTPMON i EE Dre DLSTPDOW Stop Day Of Week 6 ok def DLSTPDOW O Points DLSTPWK Stop Week 5 ok def DLSTPWK GB Usercorfiguration DLSTPTIM Stop Time 02 45 ok def DLSTPTIM d DISTPADV stop Back 45 0 ok def min DLSTPADY SOMES POWERUP Power on Delay Al EE a E O DAYSAY DLSTRMON DLSTRDOW DLSTRWK DLSTRTIM DLSTRADY DLSTPMON DLSTPDOW DLSTPWK DLSTPTIM DLSTPADY POWERUP d Palette i S O Oca E CenNetwork fe ConDevice 83 CenTableGroup Figure 34 after point writing NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 PTE File Edit Search Bookmarks Tools Window Manager Help eo cl BIBI eD N WB pDBuamos 2 My Host tridiur tion Station ion Config Sra Dri CenNetwork Ci Points ES User
11. E E My File System Platform K l Station censtation B Config amp Services Ep Drivers NiagaraNetwork ES CenNetwork E Files ZR History 199 63 42 169 Database ConDevicel 199 63 42 183 p a Bus No Je 5 85 CenNetwork f CE E cenTableGroup Name Figure 9 Adding CcnDevice from the palette 9 1Ccn Device Status Properties e Status Status of CcnNetwork communications to this CcnDevice Possible status flags include o Ok Normal communications no other status flags o Disabled Enabled property is set to false either directly or in CcnNetwork o Down Error communicating to the CcnNetwork e Enabled Either true default or false Can be set directly or in parent CenNetwork See Status disabled description above e Health Contains properties including timestamps of last ok time and last fail time plus a string property describing last fail cause e Fault Cause If status has fault describes the cause 9 2 Ccn Device Properties busNo The bus address of the device elemNo The element address of the device deviceName Retrieved from the device with the fetch command NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 picType Retrieved from the device with the fetch command applicationVersion Retrieved from the device with the fetch command devi
12. Works should be automatically connected to the CCN through the JACE j Because CcnTunnel is enabled the JACE maintains a routing table of all CCN devices that report in Those devices like the Comfort Works application only report in every 5 minutes so give the JACE a little time to build it s routing table No harm done if you try commands early they just might not work for a few minutes NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 lt M File Edit Search Bookmarks Tools Window Manager Help a gt sl 0 8 e 25B thee x 8 anao z D O My Network gt El My Host tridium2 ccnstation 8 My Modules E My File System Platform RA station censtation B config Services B Drivers ZB NiagaraNetwork Discovered 1 objects Dev Name Bus No FlemNo Dev type IS 2 1 CC6400 D Ping Upload Download Time Broad Casting E Files ZR History Link Mark Unk From FFF E Brg hme BusNo FlemNo Device Type Status Health IpeviceStatus IE O O con EE Rename CC640002 0 2 Non Bridge ok Ok 08 Jan 09 10 01 AMIST On Line 85 ConNetwork St Reorder L CenDevice EX Composite E CenTableGroup 3 Export IZ Refresh Tree Node Go Into Figure 41 Time broadcasting as an action on CCN Network Niagara Workbene Ss ed Fil
13. answer contains an error The recommended setting for this driver is 1 which allows for up to 2 attempts before declaring a communications error Indicates how long the driver will wait for a response before declaring the CCN non responding On a poll response sequence if the response does not return within the responseTimeOut period a retry is attempted If retryCount has been exhausted a communications failure is declared Recommended setting is 2 5 seconds During the learn process the user can specify that the bridges list be cleared and start over During the create process the user can specify that CcnTables are automatically created for all tables under all devices that have been selected for CcnDevice creation Boolean value true if station is to auto create points when Pic and or Data and or FID IO tables are created Only supports creation of points under Status Display 11H and FID Status table 501H A list of the known bridge addresses Status of network level learn command busy idle or error The starting bus address to be used in the learn process The ending bus address to be used in the learn process The starting element address to be used in the learn process The ending element address to be used in the learn process Number of devices found during latest learn process At any time the user can change the units display of all values between Metric and Imperial Handler for unsolicit
14. can remove the force level command Following successful completion of the Auto command the value field s of the Point Entry and CcnOutput object will reflect a new value A point value Force command can be performed by right clicking on the CcnObject and select Actions gt Auto command Todo this the CcnObject should be added to station database We can override a value from PointListManager or we can do the same from wire sheet view NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 Niagara Workbenci File Edit Search Bookmarks Tools Window Manager Help 2 gt Gel dAD S eB ROR X S My Host tridium2 censtation Station censtation Config a Drivers nNetwork E IRHBRO Ss CC6400_0_2 RTCCNOOC X Nav Qu Omne lei Bl My Host tridium2 ccnstation Database TIMEBCST O Damen O DLSTRMON DLSTRDOW DLSTRWK DLSTRTIM O DLSTRADY DLSTPMON DLSTPDOW DLSTPWK DLSTPTIM O DLSTPADY POWERUP EB My Modules E My File System Platform E Station ccnstation E Config E Services ZB Drivers NiagaraNetwork El CenNetwork ie CC6400_0_2 amp Alarm Source Info o Points UserConfiguration E ELEPHANT E TIGER E ADAPTO1C Y abcdefg 5 cmatuz2p PJ SENSDI_C 3 cyrouozc 3 DIscro_P fa PuLsp
15. data and then downloaded to the field device Note If download the logic to the controller we don t have clarity on whether the device will work or not So we couldn t test this feature Fetch This action will fetch additional information of device when user manually adds a new device with correct bus and element numbers NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 pubs 2 de My Modules E My File System Platform ff Station censtation B Config Services Ef Drivers Go NiagaraNetwork El ConNetwork K T mm d gt Upload Download Palette Fetch amp K Ac Cia Duplicate SJ CenNetwork EE amp SE ee El CcnTableGroup B Find Link Mark Link From Link To Rename St Reorder FA Composite Refresh Tree Node Go Into Figure 13 Actions on CcnDevice 10 Ccn Table Manager The Cen Table Manager is the default view when you double click on Point extension under Con Device in the Nav tree This manager view provides a quick and easy way to display and learn Ccn Tables that are on the Ccn device The Cen Table Manager is a table based view where each row represents a unique table When building a device in the station you use this view to create edit and delete table level components Below is an example Ccn Table Manager View for discovery and adding tables to s
16. erway eave kes 39 ES ACU ONS OM Coapa 43 LSA SECC OMAN EE 43 18 2 Override Command sesion diia 44 LES Auto Command TT 44 TOCA AB TSG IN Ge A A a iia hide Lac 49 20 CCN Device Upload cidad 50 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 ZAMS IDE VICE DO WAG AGF aa io aisha alessandra ee 50 22 Other Cen Utility PUnctioms sssini Ide inii 50 22 1 CCN Alarm Acknom IGS EE 50 22 2 CCN Broadcast ACknOW led eh o janta ae de O E eia 50 22 CCN Time Broa L cesar SN E 50 23 ComfortWorks Tunneling Through JACE 51 23 Limitations Changes made to AX CCN driver 53 SE EE 53 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 1 Objective The Carrier Communication Comfort Network which shortly known as CCN driver provides the components necessary to integrate CCN devices and data into the Niagara environment The CCN Driver is made up of three primary components 1 The CCN Network 2 The CCN Device and 3 a collection of Niagara objects to shadow I O and variables in the CCN network This is a serial driver 1 1 The CCN Network The CCN Network component is a container object used to track the status of the entire CCN track and perform time synchronization between the CCN system and the Niagara system and provide support
17. for automatically creating Niagara shadow objects by learning devices or controllers within the CCN 1 2 The CcnDevice The CCN Device component is a container object used to track the status of a CCN device track and perform time synchronization between the CCN device and the Niagara system and provide support for automatically creating Niagara shadow objects by learning tables within the CCN device 1 3 Cen Shadow Objects The CCN driver provides support for several different types of data much of which is accessible via the CCN system gt CcnTableGroup A container within which to organize CcnTable shadow objects gt CenPicTable A shadow object for the CCN PIC Table type gt CenPocTable A shadow object for the CCN POC Table type gt CenDataTable A shadow object for the CCN DataTable type gt CcnDataTablewithTimeSchedule A special shadow object for the CCN DataTable time schedule type that can be represented either in tabular form as other tables are or graphically as a time schedule gt CcnFidTable A shadow object for the CCN FidTable type gt CcnFidTablewithTimeSchedule A special shadow object for the CCN FidTable time schedule type that can be represented either in tabular form as other tables are or graphically as a time schedule gt CcnAHTable A shadow object for the CCN Alarm History Table type gt CenlnputProxy Shadows the behavior of the CCN Input Point under a CcnPicTable gt CcnOutputPr
18. only property which goes to field device After changing the table name from property sheet user should invoke fetch action on table Then the table name will change to the new name given by user Invalid table name will be treated as T First 8 characters of the name will go to the field device Note User should change the tableName property from property sheet only Try to avoid renaming the table name from wire sheet slot sheet etc Observation This operation is controller specific tableBlockCount Table s block count generally 10 15 learnStatus Status of controller level learn command busy idle or error NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 pointLearnCount Number of points found during latest learn process pointCreateCount Number of points created during latest create process For a POC table additional properties are dataTableType type of datatable which resides beneath it dataTableLearnCount Number of data tables found during latest learn process dataTableCreateCount Number of data tables created during latest create process For a Data Table dataBlock The data block in the data table where this point data values are located C RTCCNOOC Cen Pic Table 1 O Table Type Table Type String UserConfiguration 3 Table Instance 1 Table Num 6 _ Table Name RTCCNOOC 3 Ta
19. units unitsEnum valueBlock valueBlockOffset 50 numberOfDecimalPlaces 51 doubleTimelnFourBytes Display type per the point format information from the device True means Metric False means Imperial All data values in the devices are stored in Imperial We do not use this property but instead use the global property on the CcnNetwork Config tab named displayMetric Point s display digits requirements The upper nibble is the number of digits to the left of the decimal and the lower nibble is the number of digits to the right of the decimal For dataType 0 eightBitFlags the upper nibble specifies the number of usable bits in the byte right to left This value is displayed in decimal and must be converted to hexadecimal to be interpreted for instance a 97 decimal is a 61 hex and thus up to 6 digits to the left of the decimal and 1 digits to the right will display Point s byte count in the table value block Point s discrete text offset if it s discrete flag is set Point s config flags Valid values are bit 0 this point has a low limit bit 1 this point has a high limit bit 7 this point is a discrete point This value is displayed in decimal and must be converted to hexadecimal to be interpreted For instance a 128 decimal is an 80 hex and thus it is a discrete point but does not have a low or high limit Another common value a 125 decimal is an 83 hex and thus it is a discrete point t
20. 3 objects Name Description Jos UnitsEnum Field Status Force Level FieldName JE Bo Oiii y Time Broadcast Enable Disable ok def TIMEBCST Platform O pavsav Daylight Savings O stae def paan Station censtation DLSTRMON Start Month 10 ok def DLSTRMON E Config DISTRDOW Start Day Of Week 319 def DLSTRDOW EP Services DLSTRWK Start Week 5 ok def DLSTRWK SE Drivers DLSTRTIM Start Time 03 45 ok def DLSTRTIM SB NiagaraNetwork O DISTRADY Start Advance 50 0 ok def mp DLSTRADY amp Cenetwork DLSTPMON Stop Month 12 ok def DLSTPMON eN P ie DLSTPDOW Stop Day OF Week 6 ok def DLSTPDOW points DLSTPWK Stop Week 5 ok def DLSTPWK EB UserConfiguration DLSTPTIM Stop Time 02 45 ok def DLSTPTIM O DLSTPADV stop Back 45 0 ok def min DLSTPADY E POWERUP Power on Delay 6 0 oh det ee EE O Davsav DLSTRMON DLSTRDOW DLSTRWK DLSTRTIM DLSTRADY DLSTPMON DLSTPDOW DLSTPWK DLSTPTIM DLSTPADY POWERUP E Palette d SD 0 CCN F S ConNetwork de CenDevice E CenTableGroup Figure 33 giving a new value for point write File Edit Search Bookmarks Tools Window Help es O S HEDB IxhNBRX gt RBABMO SS 2 CenNetwork CC6400_0_2 9 Points ES UserConfiguration RTCCNOOC cn Point List M Nav Database 13 objects Qo Owner TS Name
21. AENA L CenDevice El CenTableGroup Figure 6 Adding CcnDevice to station database If you highlight one or more rows in the top Discovered pane then Add button becomes active You can now add the selected devices to the station database by clicking the Add button Note As in Normal drivers the CCN driver doesn t open a dialog window before adding the learned entry to station database Simply it adds the entry to station database If user wants to edit anything deviceName busNum elementNum user can do the same by clicking on Edit button If user selects the property createTables as true and autoCreatePoints as true then tables will be discovered and the points which are under Status Display group will be added along with the device _ Create Tables Otrue rl _ Auto Create Points O true rl Figure 7 Auto create Tables and Points The user can add a ccn device by using the new button from the Cen Device Manager NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 El My Host ie10dtx66qvb1s Station ccnstation Config a Drivers CenNetwork Nav Q x e My Network J E My Host ie10dtx66qvb1s 8 My Modules E My File System Platform Station censtation B Config E Services ZB Drivers CN ACE Device Type Device Status g
22. A_ALcO O WRSYS_ST E Rename Ctrl R O PMP_sPD St Reorder 63 Maintenance EB Composite EB setPoints F Alarmbista d 3 Export Palette D New GD 5 CCN EJ Edit S CenNetwork D CenDevice E CenTableGroup Figure 39 Auto operations on overridden point Magara Workbenc no ll Xx File Edit Search Bookmarks Tools Window Manager Help R t D B BR LD N hee x GUBAO gt Z My Host tridium2 censtation tion ccnstation Config XS Drivers E ConNetwork gt CC6400_0_2 Points S StatusDisplay SWP65 96 Con Point List Manager Nav S Database 4 objects D O my network JH p o unitsEnum Field Status Forcetevel FieldName El ST Supply Fan VFD Status Off ok def SEVFD ST El My Host tridium2 censtation Supply Air VFD Algo 0 0 ok def SA ALGO da My Modules Water System Status Off ok def WRSYS_ST Lie System Secondary VFD Pump Speed 70 0 ok def PMP_SPD Platform R Station censtation B Config Services ZB Drivers ZB NiagaraNetwork EB CenNetwork Ge cces00 0 2 D Alarm Source Info Points EI UserConfiguration E StatusDisplay E Hweo1_32 HWP33 64 6 54_ALGO WRsyS_ST PMP_SPD D Proxy Ext 83 Maintenance E SetPoints Palette E O con E S CenNetwork CenDevice E CenTableGroup Figure 40 after auto 19 Table Polling In CCN driver Polling will
23. Bookmarks Tools Window Help 149 Build2 Station Build2 a My Network Y Cy lx 79 NiagaraNetwork 85 CenNetwork fla D_203FID Q Alarm Source Info Points GQ StatusDisplay 10 Points TimeSchedules Oia 5 Holiday Hetz SetPoints ses D Network Alarm Source Ge TeLINK Palette a B 85 CenNetwork fs CenDevice EI CenTableGroup a Drivers Cemletwork FID Points g Timeschedules edule Manager Time Schedule List For TST1 Schedules s Eli Tuesday Wednesday Thursday R DD DD DS 0000000 0000400 Friday 0040000 Saturday DEDODO DRRDR S Period Period 1 Period 2 Period 3 Period 4 Period 5 Period 6 Period 7 NIAGARA AX CCN Driver User Manual B indo Figur m Magar ga Java E Java Th Niagar KU J untitle Za 137 19 Niagar e 29 Ccn Time Schedule Manager BEBE SS Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Drivers CenNetwork E TimeSchedules 2 D_203FID K Points Snin ren iren Database Name Description Jo Units Enum Field Name Period 1 Occupied from 00 18 ok def T502 Period 1 Occupied to 23 50 ok def T502 T503 Period 1 Day of Week 11111111 ok def T503 T504 Period 2 Occupied from 03 0 ok de
24. Cen Add P 1C Points Success gt D Q 8 My Network El Discovered E My Host tridium2 censtation GB My Modules OCCLOW E My File System Platform FA Station ccnstation B Config 2 Services ZB Drivers CB NiagaraNetwork El ConNetwork Ge cc6400_0_2 amp Alarm Source Info Points 83 UserConfiguration ED StatusDisplay E Maintenance B setPoints 0 EB AlarmHistory Network Alarm Source E Files ZR History Facts De e o Dc j O oco Occupied Hi Setpoint 24 0 ok der psig OCCHGH UNOCCLOW Unoccupied Lo Setpoint 15 0 ok def psig UNOCCLOW 8 Cenlletwork O UNOCCHGH Unoccupied Hi Setpoint 15 0 ok def psig UNOCCHGH YG CenDevice O occLoW Occupied Lo Setpoint 24 0 ok deF psig occLow E CenTableGroup Figure 43 Point display when displaymetric is false Observation On changing of display metric property sometimes units are not changing until user does workbench refresh 23 Limitations Changes made to AX CCN driver For time related CCN points the user should give value in hh mm format to set a new value The driver doesn t show any error message on UI side But it will be thrown in console side 2 Testing is not performed for the following functionality checks 1 Alarm Acknowledgement 2 Time Broadcasting and broadcast Acknowledgement 3 Driver force levels 4 Tunneling is supported The features of upload download options
25. Configuration Be CMAIU22D OARH Con Data Points List Manager Nav Database 7 objects BO Ome H Name out E Low Input Endpoint 4 0 ok def LOWRANGE High Input Endpoint 20 0 ok def mA HIGHRNG Low Conversion Endpoint 0 0 ok def RH LOWCONY High Conversion Endpoint 100 0 ok def RH HIGHCONY Low Input Fault 4 0 ok deF mA LOWFLT High Input Fault 20 0 ok def m HIGHFLT Externally Powered No ok def Platform BA Station censtation E Config services Ef Drivers B NiagaraNetwork El CenNetwork Ge cces00 0 2 amp Alarm Source Info Points 89 UserConfiguration C rTrecnooc C ELEPHANT C TIGER C ADAPTOIC D abcdefo y cmaruz2o JE OAH_SARH Py SENSDI_C Py cyrouozc Pa DIScRO_P E PULSDI_C Py consume Pa cmaruzoc d Palette Di Solo E S CenNetwork E CenDevice E CenTableGroup Figure 35 Data table point write Niagara WORE ee File Edt Search Bookmarks Tools Window Manager Help 2 2 0 DATA S AEB h Sx o DBBmaos lt Config a Dri J CenNet E gt CC6400_0_2 ES UserConfiguration Be CMAIU220 OARH Cen Data Points List Manager ly Host tridium2 ccnstation Station c Nav IS Database 7 objects D SR My network JH Name Description Jo JunitsEnum FieldName EI LOWRANGE Low Input Endpoint 4 0 ok def mA LOWRANGE a HIGHRNG Hi
26. Description Out Units Enum Field Name Figure 27 Point s discovery on a FID table NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 OQ cen Add Fid Points Discovered 5502 5503 5504 5505 Database Name Description Out Units Enum Field Name 5502 High value occupied 75 0 ok O def oF 502 5503 High value unoccupied 78 0 ok def oF 5503 5504 Low value occupied 68 0 ok def oF 5504 5505 Low value unoccupied 64 0 ok def oF 5505 Figure 28 Adding points to station database 16 Ccn Time Schudule Manager CcnTimeScheduleManager is a tabular view which will be available on tables of type DataTableWithTimeSchedule or on tables of type FIDTableWithTimeSchedule From this tabular view user can select deselect the check boxes available under week days and can change the time under fields From and To User can save these values to the controller by using SaveTimeSchdules option The changes will be reflected in Cen Fid PointList manager The changes done in CenFidPointList manager will be reflected in CcnTimeScheduleManager and vice versa The screen shot for Ccn Time schedule Manager is as follows NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 Niagara Workbench Edit Search
27. Driver Version No 1 0 User Manual Date 11 11 2010 18 2 Override Command If a CcnOutput object is a discrete point type it can be forced on value of 1 active text defined by the one s value of the discreteT extOffset text pair It can be forced off value of O inactive text defined by the zero s value of the discreteTextOffset text pair The Cen Driver manages two force levels level 4 is used for commands level 8 is used for links and the auto level 0 The command level force is the highest priority available from the Ccn Driver If CcnOutput object is a discrete point type the command will open a combo box which will have Force On Discrete on Text and Force Off Discrete off Text options Selecting either of these commands will result in a Force command being issued Following successful completion of the Force command the value field s of the Point Entry and CcnOutput object will reflect the new value The Entry from the PointListManager will change to lavender color A point value Force command can be performed by right clicking on the CcnObject and select Actions gt Override command To do this the CcnObject should be added to station database We can override a value from PointListManager or we can do the same from wire sheet view Observation Some of the points are not overriding properly The same behavior is observed in R2 18 3 Auto Command The CcnOutput objects can be autoed The auto level command
28. I_c PY CONSUME Palette Su E CenNetwork CenDevice 8 E CenTableGroup NIAGARA AX CCN Driver User Manual Time Broadcast Enable Da igt ht Sa vings Js ee Start Month Start Day OF Week Start Week Start Time Start Advance Stop Month Stop Day OF Week Stop Week Stop Time Stop Back Power on Delay O stale de Disable ok def 10 ok def 3 ok def 5 ok def 03 45 ok def 50 0 ok def min 12 ok def 6 ok def 5 ok def 02 45 ok def 45 0 ok def min Views New Da Copy Ctrl C OP Paste Chevy FB Paste special Cia Duplicate Ctrl D BG Find Link Mark Link From Link To St Reorder FA Composite Depot D Nem EJ Edt Points gt Y cut Ctri X X Delete Delete Rename Ctrl R Figure 32 Screen for point write d UserConfiguration Name Description Joe Units Enum Field Status Force Level Field Name TIMEBCST DAYSAV eel DLSTRMON DLSTRDOW DLSTRWK DLSTRTIM DISTRADY DLSTPMON DLSTPDOW DLSTPWK DLSTPTIM DISTPADY Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 TENES File Edit Search Bookmarks Tools Window Manager Help RHAMOs e gt D 8ab s 2oB n ax 2 My Host tridium2 tion constation Config 3 CenNetwork E CC6400_0 Es UserConfiguration RTCCNODC A Cen Point List Manager Database 1
29. Rl on E ET 83 CenNetwork L CcnDevice ES CenTableGroup Figure15 Adding CcnTables to station database Once the user clicks on Add all tables will be added in a category manner under a device My Host iel0dtx66qvbis Station ccnstation Config E Drivers NiagaraNetwork Ei ConNetwork Ge CC6400 A Alarm Source Info o Points UserConfiguration E StatusDisplay d N Ci Ca EL Network Alarm Source Files ZR History 5 Figure 16 CcnNetwork hierarchy after adding tables to the device If the table type is POC table we can discover the Data Tables under a POC table NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 orkbench Search Bookmarks Tools Window Manager Help tnr Aras HEBA eg aHa o e tion censtation Config a Drivers 3 CenNetwork E cc6400 K Points ES UserConfiguration Be CMAIU220 Con Data Table Manager Ccn Learn Data Tables Success gt gt bl My Network 7 E UserConfiguration RTCCNO0C E ELEPHANT E TIGER E apaptoic y abedefg Beate y SENSDI_C Py cvrouozc Pa DISCRO P y PULSDI_C Py CONSUME Py cmaruzoc Py cmaruosc Discovered Table Type Table Type String OARH 4886 UserConfiguration OAH_SARH 4886 UserConfiguration A Dat
30. ST 25 Jun 02 12 00 AM IST SB NiagaraNetwork CC6400 0 2 ALERT O at 31 Dec 02 4 50 PM IST 18 Jun 02 12 00 AM IST amp ConNetnork CC6400 0 2 ALERT 0 at 31 Dec 02 2 48 PM IST 18 Jun 02 12 00 AM IST Ge cc6400_0_2 o A Alarm Source Inf CC6400 0 2 ALERT O at 31 Dec 02 2 16 PM IST 14 Jun 02 12 00 AM IST d Points pure ia CC6400 0 2 ALERT O at 31 Dec 02 5 46 PM IST 13 Jun 02 12 00 AM IST CC6400 0 2 ALERT O at 31 Dec 02 12 16 PM IST 13 Jun 02 12 00 AM IST E UserConfiguration CC6400 0 2 ALERT O at 31 Dec 02 9 01 AM IST 13 Jun 02 12 00 AM IST StatusDisplay E Maintenance CC6400 0 2 ALERT O at 31 Dec 02 4 14 PM IST 12 Jun 02 12 00 AM IST A SetPoints CC6400 0 2 ALERT O at 31 Dec 02 9 15 AM IST 12 Jun 02 12 00 AM IST Alarmbistory CC6400 0 2 ALERT O at 31 Dec 02 3 29 AM IST DI CC6400 0 2 ALERT 0 at 31 Dec 02 2 31 AM IST amp Network Alarm Source CC6400 0 2 ALERT 0 at 31 Dec 02 6 37 AM IST E Files CC6400 0 2 ALERT O at 31 Dec 02 6 23 AM IST y History E Database e Name Talam Tei DIO ce 7 83 CenNetwork a CenDevice E CenTableGroup Figure 26 Alarm History Table 15 Cen Fid Point List Manager The Cen Fid Point List Manager is the default view when you double click on FID table which is learnt from an FID type device This manager view provides a quick and easy way to display and learn Cen Points that are on the Cen Fid Table The Cen Fid Point List Manager is a
31. Schedule Tables can have up to 21 points with field Index ranging from 0 20 Fid Holiday Tables can have up to 60 points with field Index ranging from 0 59 this point s name 8 ASCII characters fieldName NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 dataType dataTypeEnum Fid IO Points Tables has up to 64 points Each point s name can be modified from Niagara by changing it from the property sheet and invoke fetch action Point s data type 00 33H Point s data type enumeration O eightBitFlags 1 unsignedChar 2 unsignedlnt 6 BEST_FloatingPoint 7 IEEE_FloatingPoint 9 signedChar 10 signedint 12 timelnTwoBytes 16 Name 17 BCD 18 controllerName 19 controllerName 20 controllerName 21 controllerName 22 pointName 23 pointName 24 pointName 25 schedulePointNo 26 schedulePointNo 27 schedulePointNo 28 schedulePointNo 29 schedulePointNo 30 schedulePointNo 31 schedulePointNo 32 phoneNumber 33 password 34 ASCII 48 linkedFloatingPointValue 49 numberOfDecimalPlaces NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 displayType displayDigits fieldByteCount discreteT extOffset configFlags
32. ZB NiagaraNetwork ConDevice O SEEN E Files ZR History O Name Ecndevice 199 63 42 183 a Onemno aa O Device Type Unknown Je Ss a E Cenilet work E corals o cancer E ConTableGroup o Cancel X Palette Figure 8 Adding a CcnDevice by New option from CcnDeviceManager 9 Ccn Device A CcnDevice object can only be added to a CcnNetwork container A CcnDevice is most conveniently added during the CcnNetwork s Device Manager Creation process Alternatively a CcnDevice may be added to an existing station using the New button on Device Manager To do so drag and drop the CcnDevice object from palette to Ccnnetwork under station This will add the CcnDevice to the CcnNetwork If this approach is taken the user will need to go to the CcnDevice Config tab and set the busNo elemNo properties to the actual address of the device to be shadowed Then a fetch action on device will retrieve additional needed device information like pic type part no model no etc NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help e gt t Arale HUBA oaa 0 16 0 My Host ie10dtx66qvb1s nstation Config Drivers E CenNetwork Nav Q S Discovered Bl My Modules E
33. abase Figure17 CcnDataTable Discover Niagara Workbench EE x File Edit Search Bookmarks Tools Window Manager Help e gt t DATAS BEB YRBDx o e Raa o e Station ccnstation Config XS Drivers CenNetwork E CC6400 K Points ES UserConfiguration O Con Data Table Manager E OQ Cen Learn Data Tables Success X Bast E E UserConfiguration E RTCCNOOC E ELEPHANT E TIGER 5 ADAPTO1C abcdefg Be Mame 5 Discovered Table Name Table Type_ Table Type String 4886 LU OAH_SARH SENSDI_C Py cytouozc PG DIscRO_P E PULSDI_C a consume Py cmamuzoc Py cmatuo3c Database Name Table Name Table Type String N Palette s m ll El CenNetwork amp EES E CenTableGroup La new El Edi 88 Discover O Conce d ada Match E Inbox Mic Java BCc Niagara Co EM Niagara Co Figure 18 Adding Data Tables under POC table NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 11 CcnTable The collection of CCN shadow table objects model the tables of a CCN controller The following shadow table objects are provided The following shadow tables are provided CcnPicTable Models a single Pic table defined by table type and table instance CcnPocTable Models a single Poc table defined by t
34. able related information Please refer the table Name property from section 11 2 11 3 CCN table addition 12 Ccn Point List Manager The Cen Point List Manager is the default view when you double click on PIC table which is placed under a CcnTableGroup in the Nav tree This manager view provides a quick and easy way to display and learn Cen Points that are on the Cen PIC table The Cen Point List Manager is a table based view where each row represents a unique point When building a device in the station you use this view to create edit and delete point level components Below is an example Cen Point List Manager View for discovery and adding points to station database Sys W I E MY LE 00 Li es 1 ap rat Kall pm ze Station ccnstation Config Drivers C3 CenNetwork cc 400 f Points 6 UserConfiguration RTCCNOOC O Cen Learn P I C Points su R K Sm Network y Discovered Ge cc6400 D Alarm Source Info Points EI UserConfiguration E E E ELEPHANT E TIGER ADAPTO1C Y abcdefg Py cmaluz2o Py SENSDI_C 3 cytouozc a DIscRO_P Pan D M Palette S El ConNetwork E ConTableGroup Figure 22 CCN PIC table s Point discovery The Cen Point List Manager consists of either one or two main panes depending on whether or not the Discover button has been clicked The view above shows a typical Ccn Point List Manager vie
35. able type and table instance CcnDataTable Models a single Data table defined by table type and table instance CcnDataTableWithTimeSchedule Models a single Data table with Time Schedule defined by table type and table instance CcnAHTable Models a single Alarm History table defined by table type and table instance CcnFidTable For IO Points table type 501H one table entry instance 1 models all IO point tables up to 64 points 1 instance of table type 501H per point For all other Fid table types supported Time Schedules Setpoints Holidays Fid Tables model device tables 1 for 1 by table type and table instance CcnFidTableWithTimeSchedule Models a single Fid table with Time Schedule defined by table type and table instance 11 1 CcnTable Configuration The CcnTable shadow object consists of CcnPicTable CcnPocTable CcnDataTable CcnDataTablewithTimeSchedule CcnFidTable CcnFidTablewithTimeSchedule and CcnAHT able shadow objects A CenPicTable or CcnPocTable or CcnAHTable shadow object can only be added to a CcnDevice container generally under a CcnTableGroup A CcnDataTable or CcnDataTablewithTimeSchedule shadow object can only be added to a CcnPocTable container generally under a CcnTableGroup A CenFidTable or CcnFidTablewithTimeSchedule shadow object can only be added to a CcnDevice container generally under a CenTableGroup A CenTable is most conveniently added during the CcnDevice
36. and time are not used by Niagara for any purpose other than a short and quick message to perform a device status check so if they are not current and the next property devicePingStatus indicates skipped not needed since child object communicated since last ping that is good sign in that adequate successful comm activity is occurring and the devicePing that updates deviceTime is not required to run devicePingStatus The success or failure status of the device ping The ping process alternately retrieves the date and the time block A success messages would be succeeded and parsed date from ping message succeeded and parsed time from ping message NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 skipped not needed since child object communicated since last ping received date response but with NAK received time response but with NAK The NAK response merely means the specific device does not maintain date and or time Failure messages would be skipped device is out of service failed no response to date request failed no response to time request could not complete last ping isEnhancedVersion Indicates if JACE license designates this device as enhanced or not If enhanced access to configuration table data is supported If not enhanced access is limited to Display Setpoint and Time Schedule Data The
37. ble Block Count 15 3 Learn Status Idle Poll Frequency Normal Is Point Learn Count ha 3 Point Create Count 13 _ Point Force Refresh Figure 19 Property sheet for the Ccn PIC table NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 C TOUOZC Cen Poc Table _ Table Type 3 Table Type String _ Table Instance 3 Table Num 3 Table Name 3 Table Block Count Learn Status Poll Frequency Point Learn Count 3 Data Table Type _ Data Table Block J Data Table Start Block Data Table End Block Data Table Learn Count _ Data Table Create Count UserConfiguration 7 CYTOUOZC 106 ul pl DI Figure 20 Property sheet for the CCN POC table TE OAH_OAD Cen Data Table 3 Table Type 3 Table Type String 3 Table Instance 3 Table Num J Table Name 3 Table Block Count J Learn Status J Poll Frequency 3 Poc Table Type _ Data Block 1 Point Learn Count 3 Point Create Count 106 serConfiguration AH OAD dle Normal Figure21 property sheet for the CCN Data Table NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 11 3 CcnTable Actions Fetch fetches the additional t
38. ceStatus Shows whether the device is online or offline deviceDescription Retrieved from the device with the fetch command location Retrieved from the device with the fetch command partNo Retrieved from the device with the fetch command modelNo Retrieved from the device with the fetch command serialNo Retrieved from the device with the fetch command referenceNo Retrieved from the device with the fetch command platformNo Retrieved from the device with the fetch command osVersion Retrieved from the device with the fetch command deviceType Shows whether the device is of type Bridge or NonBridge primaryBaudRate Retrieved from the device with the fetch command secondaryBaudRate Retrieved from the device with the fetch command maxTableNumber The CcnDevice s TableListManager learn process will attempt to learn the maxTableNumber of a device This is beneficial because it will shorten the learn process Some devices do not support the technique used to automatically learn the maxTableNumber so the user is permitted to enter this value if it is known tableLearnCount Number of tables learned discovered during latest discovery process learnStatus Status of controller level learn command busy idle or error tableCreateCount Number of tables created during latest create process deviceTime The latest device date and time as returned in response to a query of the device s Date Time Table sent by the ping process Device date
39. cover the devices which are available under CCN Network o Select and add the CCN device s you wish to integrate e Once a device s is added navigate to the points folder under the device and double click the point s folder to display the CCN Table Manager view o Click the Discover button to discover the tables available under a particular device o Select and add Tables to the database The tables will be added in categorized manner e Once the table group s is added navigate to the table under a particular table group The table can be of type PIC POC FID For a PIC table do the following Double click on PIC table It loads the Point List Manager view o Click the Discover button to discover the points which are available under that PIC table o Select and add the CCN point s you wish to integrate For a POC table do the following Double click on POC table It loads the DataTableManager view o Click the Discover button to discover the Data Tables which are available under that POC table o Select and add the CCN Data Table s you wish to integrate o Double click on DataTable which is added under POC table It loads the Data Point List Manager view o Click the Discover button to discover the points which are available under that Data table o Select and add the CCN point s you wish to integrate NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Drive
40. dard Niagara AX network architecture Under a CcnNetwork it will have CcnDevice Normally drivers will have direct points under Points extension But Ccn will have different table groups under Points extension and table resides under table groups Actual points reside under table Diagrammatically the hierarchy would be as follows CcnNetwork gt CcnDevice gt Points Point Device Ext gt TableGroup1 gt PIC Table gt Control Pointi gt Control Point2 Control Point n gt PIC Table gt Control Point gt POC Table gt DataTable1 gt Control Point1 gt Control Point2 gt Data Table2 gt Control Point gt POC Table gt DataTable1 gt Control Point1 gt Control Point2 gt Data Table2 gt Control Point gt Table Group2 Alarm History Group gt Alarm Table gt Alarms Cen driver architecture NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 7 CCN Network For CenDriver CcnNetwork is the top level container component in a station The simplest way to add a CcnNetwork is from the Driver Manager view using the new command Or you can simply copy the CcnNetwork from the CCN palette into Drivers Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help e t DATAS DX Dap Q E My Host ie10dtx66qvb1s Station ccnstation Config Drivers
41. dcast Acknowledger The Station can be designated as the CCN Broadcast Acknowledger To do this select the broadCastAcknowledger property to true from the Network s property sheet 22 3 CCN Time Broadcaster The Station can be designated as the CCN Time Broadcaster To do this first select the timeBroadcaster property to true from CcnNetwork s property sheet When designated as the time broadcaster the JACE will Broadcast date and time onto the CCN whenever the time in the JACE changes in excess of three minutes Broadcast date and time daily at 1 00 AM and 1 00 PM on the JACE clock Broadcast date and time whenever a time broadcast request is received from the CCN NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 23 ComfortWorks Tunneling Through JACE Tunneling is the process whereby a ComfortWorks station can access a remote CCN to which a JACE is connected over RS485 The ComfortWorks station and the JACE must be able to connect to each other over IP they use UDP to communicate The JACE uses the same ports as those used by the CCN Gateway CCN Bridge hardware devices Please refer to Carriers documentation of the CCN Gateway if you need specific information about which ports are used Here are the steps required to tunnel a Comfort Works station This assumes a JACE is connected to a CCN over RS485 and runnin
42. dex _ Field Name TIMEBCST _ Field Value _ Point Data Type _ O Data Type Enum unsi gnedChar _ Display Type 1 Display Digits _ Field Byte Count _ Discrete Text Offset _ Config Flags ET _ Units _ Units Enum _ Value Block _ Value Block Offset 1 Field Status _ O Force Level _ O Lo Limit O Hi Limit _ Hi Limit Block Lo Limit Block Offset 1 Hi Limit Block Offset _ Variable No _ Description Time Broadcast Enable _ Forceable Flag _ Device Type _ Ctrl Sens Type Figure 31 CcnObject or points property sheet Note Device Type and Ctrl Sens Type properties are not used They meant for FID device Wu IF 18 Actions on CcnObject Following actions are available on CcnObject depend upon the type of the CcnObject A CcnObject can be any of the above three types mentioned earlier 18 1 Set Command Non forcible CenObject can be written with the set command A point value set command can be performed by right clicking on the CcnObject and select Actions gt Set command To do this first the CcnObject should be added to station database We can set a value from PointListManager or we can do the same from wire sheet If the value given by user is with in the limits then the new value will be written to the field device NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN
43. e Add a CCN network e 5 2 Discover and add 5 1 Add a CcnNetwork Use the following procedure to add a CcnNetwork under the station s Drivers container To add an CcnNetwork in the station 1 Double click the stations Drivers container to bring up the Driver Manager 2 Click the New button to bring up the New DeviceNetwork dialog For more details see Driver Manager New and Edit in the User Guide 3 Select CcnNetwork number to add 1 and click OK This brings up a dialog to name the network 4 Click OK to add the CcnNetwork to the station You should have a CenNetwork named CcnNetwork or whatever you named it under your Drivers folder 5 2 Discover and add CcnDevices To discover and add CCN devices do the following NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 1 Go to the Ccn Network View Enter the values for properties First Bus No Last Bus No Low Eelement No and High Element No 2 Double click the CcnNetwork or right click the CcnNetwork and select Views gt CcnDeviceManager This brings up the Ccn Device Manager 3 Click on Discover button from CcnDeviceManager 4 lt discovers the available CcnDevices which are in the given range 5 Select the discovered devices and click on Add button It adds up the devices to station database 6 CCN Architecture Essentially CCN uses the stan
44. e Edit Search Bookmarks Tools Window Manager Help D 8 aE s 25B hea x ion Stati Config Drivers Qu El My Host tridium2 censtation Bi My Modules E My File System Platform BA Station censtation B Config services Ef Drivers lt P NiagaraNetwork EI CenNetwork Ge CC6400_0_2 Q Alarm Source Info Points 83 UserConfiguration EB StatusDisplay E Maintenance UNOCCHGH 3 setPoints JE E Alarmistory D Network Alarm Source E Files ZR History Database 4 objects Name Description Ta untsemum Field status Forcetevel FieldName A so Da OCCLOW Occupied Lo Setpoint 165 5 ok def kPa OCCLOW O OCCHGH Occupied Hi Setpoint 165 5 ok def kPa OCCHGH 8 S SOK UNOCCLOW Unoccupied Lo Setpoint 103 4 ok def kPa UNOCCLOW Ed CrnDevica O UNOCCHGH Unoccupied Hi Setpoint 103 4 ok def kPa UNOCCHGH E CenTableGroup Figure 42 Point display when displaymetric true from network property sheet NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Niagara WOFKDENC E elt File Edit Search Bookmarks Tools Window Manager Help gt 0 D A20 S HEB hex egaa o My Host tridium2 censtation Station censtation Config Drivers C2 CenNetwork CC640002 Points e amp SetPoints I SETPTO3 7 Nav al
45. ed messages Checkbox select if JACE to be the CCN Network alarm acknowledger de select if not Boolean value select true if JACE to be the CCN Network broadcast acknowledger False if not Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 timeSyncStat timeBroadcaster timeSyncDisplayDots busAddress elemAddress tunnelEnable CcnTunnelHelper tunnelRxDisplayDots tunnelTxDisplayDots tunnelRxDebugOn tunnelTxDebugOn NIAGARA AX CCN Driver User Manual Reports if time sync service is started or stopped Checkbox select if station is to be the CCN Network time broadcaster Normally set to False setting to True will enable a T character to displayed in the diagnostic output every timeSync cycle The CCN bus address that the Niagara Station is connected to generally the primary bus bus 0 The CCN element address on the busAddress that the Niagara Station is assigned generally a high element number just below the broadcast address range typically 230 239 Do not use same address assigned to Comfort Works application that you might decide to tunnel for setup and configuration checkbox select to enable tunneling for the JACE Since tunneling consumes station resources in order to maintain IP communications to ComfortWorks stations it is recommended that this feature be disabled unless tunneling of ComfortWork
46. f T504 O T505 period 2 Occupiedto 04 0 ok def T505 T506 Period 2 Day of Week 01000001 ok def T506 T507 Period 3 Occupied from 05 0 ok def T507 1508 Period 3 Occupied to 06 0 ok def T508 T509 Period 3 Day of Week 00100001 ok def T509 T510 Period 4 Occupied from 07 30 ok def T510 T511 Period 4 Occupied to 08 30 ok def T511 O T512 Period 4 Day of Week 00000000 ok def T512 1513 period 5 Occupied from 09 0 ok def T513 HO T514 Period 5 Occupied to 10 0 0k def T514 O T515 Period5 Day of Week 00001001 ok def T515 T516 Period6 Occupied from 11 0 ok def T516 1517 Period 6 Occupied to 12 0 ok def T517 T518 Period 6 Day of Week 00000101 ok def 1518 O T519 Period 7 Occupied from 11 0 ok def T519 T520 Period 7 Occupied to 11 45 ok def T520 T521 Period 7 Day of Week 10000000 ok def Ts21 Figure 30 Ccn Fid Point List Manager 17 Ccn Points The collection of CCN shadow point objects model the real and internal I O as well as selected internal modules of a CCN controller The following shadow objects are provided Type Behavior Where it is valid CenInputProxy Models a single Input under CcnPicTable types Point defined by field index 11H and 12H applies to and field name in the non forcible points table An Input Point is one that is not forceable or writeable CcnOutputProxy Models a single foceable under CcnPicTable
47. from Comfort View tool are not tested for JACE 5 Driver supports a single ccn network per station and is tested with single network trunk per station It is not tested on 2 comm ports of a JACE 24 Performance Niagara AX driver is tested in Win XP soft JACE JACE 6 Soft JACE System configuration RAM 2 GB Hard Disk 80 GB Speed 2 33 GHz NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 JACE 6 System configuration Power PC 440 524 MHz processor 128 MB DDR RAM amp 128 MB Serial Flash Optional 256 MB DDR RAM NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010
48. g a station with the Ccn driver installed This also assumes that Comfort Works is installed on a PC that has access to the JACE over an Ethernet connection 1 Enable tunneling in the JACE a Open the CCN station in Workbench b Visit the property sheet of the CcnNetwork c Check the tunnelEnable property d Confirm that your JACE station has a different CCN address from Comfort Works usually Comfort Works is addressed as 0 239 2 Configure a ComfortWorks station to connect using Local Direct Connection ee Gateway Launch Carrier Network Manager b To use existing CCN database in ComfortWorks From the System Overview window right click an existing CCN Choose Modify The Modify CCN Definition dialog should appear c To create new CCN database in ComfortWorks From the System Overview window right click somewhere in the empty space Choose New Then choose Carrier Comfort Network CCN Enter a name in the New CCN Definition dialog that appears d Click the Access button This should take you to the CCN Access Definition dialog e For Method Towards the top of the dialog choose Local Direct Connection CCN Ethernet Gateway f Then the CCN Ethernet Gateway IP address field somewhere below the Method field should become enabled Please enter the IP address of JACE in this field g Click OK at the CCN Access Definition dialog h Click OK at either the New or Modify CCN Definition dialog i Atthis point Comfort
49. gh Input Endpoint 20 0 ok def mA HIGHRNG O LOWCONY Low Conversion Endpoint 0 0 ok def RH LOWCONV HIGHCONV High Conversion Endpoint 100 0 ok def RH HIGHCONY O LOWFLT Low Input Fault 4 0 ok def mA LOWFLT HIGHFLT High Input Fault 20 0 ok def mA Platform R Station ccnstation B config Services Ep Drivers ZB NiagaraNetwork amp CenNetwork Ge CC6400_0 2 amp Alarm Source Info Points EI UserConfiguration Grrccnooc GJ ELEPHANT E TIGER Gj apartoic PJ abcdefg a cmaruz20 E JE OAH_SARH Py sENsDI C Py cvrouozc Pa Discro P a PULSDI_C Py consume Py cmaruzoc EXTPOWER _ Externally Po Yes ok def Palette Solo S CenNetwark CenDevice E CenTableGroup Figure 36 after point write NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver User Manual Niagara WOrkKDENc Ss LS File Edit Search Bookmarks Tools Window Manager Help gt 0 D A20 S 2 D N Doppel Cen Point List Manager 4 objects Name J eseegpen Jo Units Enum Field Status ForceLevel FieldName Supply Fan VFD Status OFF ok O def El My Host tridium2 censtation a Supply Air VFD Algo 0 0 ok def 8 My Modules Water System Status Off ok def E My File System Secondary VFD Pump Speed 7 def Platform
50. ght result from licensing error The Health slot contains historical timestamp properties that record the last network status transitions from ok to any other status The Fault Cause property further explains any fault status 7 2 CCN Network monitor notes The CenNetwork s monitor routine verifies to Ping the child Cendevices with ping frequency duration For general information see About Monitor in the User Guide 7 3 CCN Network views The CenNetwork s default view is Cen Device Manager equivalent to the Device Manager in most other drivers Use this view to discover and add Ccn Device components to the station Another view is Cen Network View which is equivalent to property sheet Other standard views are also available on the CcnNetwork However apart from the Cen Device Manager we typically access only its Cen Network View 7 4 CCN Network Properties NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 retryCount responseTimeOut sec clearBridgeList createTables autoCreatePoints bridges learnStatus firstBusNo lastBusNo lowElemNo hiElemNo deviceLearnCount displayMetric UnsolicitedReceiveHandler alarmAcknowledger broadcastAcknowledger NIAGARA AX CCN Driver User Manual Indicates how many additional times a request for data will be sent to the CCN if the first attempt fails or the
51. happen on Table level CenPicTable and CcnDataTable objects become registered to poll when they are in view The tables which are in view will be polled NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 as per poll frequency The default frequency is the Normal frequency and the user can change the frequency duration 20 CCN Device Upload A CcnDevice s CcnPicTables CcnPocTables CcnDataTables and CcnFidTables can be uploaded The upload command is available as an action on the CcnDevice When invoked a list of CcnTable blocks are uploaded and all Station resident data is updated to match that which was retrieved from the field device 21 CCN Device Download A CenDevice s CenPicTables CcnPocTables CcnDataTables and CenFidTables can be downloaded The download command is available as an action on the CcnDevice When selected each non real time table s value blocks are constructed from the Station resident data and then downloaded to the field device Note If download the logic to the controller we don t have clarity on whether the device will work or not So we couldn t test this feature 22 Other Cen Utility Functions 22 1 CCN Alarm Acknowledger The Station can be designated as the CCN Alarm Acknowledger To do this select the alarmAcknowledger property to true from the Network s property sheet 22 2 CCN Broa
52. hat does have a low and high limit Point s integer units value Point s integer units enumeration See Appendix 1 for valid values Point s value block assignment Point s value block offset assignment loLimit Point s lo limit value loLimitBlock Point s lo limit block assignment NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 loLimitBlockOffset Point s lo limit block offset assignment hiLimit Point s hi limit value hiLimitBlock Point s hi limit block assignment hiLimitBlockOffset Point s hi limit block offset assignment variableNo Point s variable number only applies to points under 11H 12H and 501H tables description Point s 24 character description forceableFlag Point s forceableFlag ForceableFlag is False for a CcnInput and a CcnNonForceableOutput ForceableFlag is true for a CcnOutput if the point is in a 11H 12H or 501H table type and the point has a hiLimit value and the point has a non zero variableNo CcnOutput s with forceableFlag True can be controlled with Force and Auto commands ForceableFlag is false for a CcnOutput otherwise CcnOutput s with forceableFlag False can be written with the Set command NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 _ Field In
53. n points By clicking the Discover button the learn mode of the manager is invoked the panes will be split and a discovery table will be displayed in the top pane The progress of the discover points process can be viewed from learn status from table s property sheet Once the discovery job is complete the top half pane of the point manager will display a table of Points discovered sec GT UT PIT Le o Na L amp 4 a LE EM QW a e Config fg Drivers CenNetwork CC6400 amp Points 229 UserConfiguration Be CmaIU22D O Ccn Data A iv ki Con Learn Data Points D 7 m ve les Ge cce4o0 2 Alarm Source Info LOWRANGE Points HIGHRNG es UserConfiguration LOWCONY E RTCCNOOC HIGHCONY E ELEPHANT LOWFLT E ES TIGER HIGHFLT E ADAPTOIC EXTPOWER 5 abcdefg Pa cmatuzzp B Database n Description Out Units Enum_ Field Name Palette S CcnNetwork o EEES ES CcnTableGroup Figure 24 Points discovery on CcnDataTable NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 eech a LI EE L peo amp figuration ie cma fa CC6400 A Alarm Source Info o Points E UserConfiguration RTCCNOOC HIGH CJ ELEPHANT LOWFLT el TIGER HIGHFLT SHEJ ADAPTOIC EXTPOWER Py abcdefg
54. n the Niagara AX User s Guide in the Driver Architecture section The Match button is not used for the Ccn driver The Discover button does implement functionality that is unique and tailored to discovering Ccn devices By clicking the Discover button the learn mode of the manager is invoked the panes will be split and a discovery table will be displayed in the top pane The progress of the discover devices process can be viewed in learnStatus property from Ccn Network View Once the discovery job is complete the top half pane of the point manager will display a table of devices discovered see following figure NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help eco t D Arale HB he A x psDp Bea El My Host ie1Odtx66qvbis Station censtation Config Drivers 3 CcnNetwork O Cen Learn Devices De O my Network El My Host ie10dtx66qvb1s E Bi My Modules E My File System Platform Kl station censtation E Config 2 Services Ef Drivers ER NiagaraNetwork E Files ZR History 199 63 42 169 199 63 42 183 D Discovered Add Ctrl 4 Match Chl Show Existing Select All Database Palette D S K Bco gt
55. nowledgement this parameter defines the number of times that the JACE should resend the packet of data The recommended setting for this property is two retries When the JACE sends tunnel data to a ComfortWorks it expects an acknowledgement of receipt from the ComfortWorks This parameter defines the number of milliseconds that the JACE should wait for the acknowledgement of receipt from the ComfortWorks If the acknowledgement of receipt is not received during this interval of time after transmission then the JACE will retry the number of times specified by the property tunnelRxRetryCount The recommended setting for this property is 1000 milliseconds Boolean property true if JACE to be the CCN Network broadcast acknowledger false if not If selected low level native code specific debug text will be generated and sent to the administrator console window Default is 0 Do not use this property without the assistance of Tridium Engineering in an effort to isolate a specific problem you have reported Comm port through which communications to the CCN will take place User should enter one of the available port on JACE to which CCN trunk has connected to Set to match the baud rate of the bus of the CCN Network to which the JACE is connected default is 9600 Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 a Drivers C3 CcnNetwork A Con Network View v
56. orce Level Field Name Palette S amp Econ gt El CcnNetwork f s EE El CenTableGroup Figure 23 Adding Ccn Points to station database 13 Ccn Data Point List Manager The Cen Data Point List Manager is the default view when you double click on Data table which is place under a POC table in the Nav tree This manager view provides a quick and easy way to display and learn Cen Points that are on the Cen POC table The Cen Data Point List Manager is a table based view where each row represents a unique point When building a device in the station you use this view to create edit and delete point level components Below is an example Ccn Data Point List Manager View for discovery and adding points to station database NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 The Cen Data Point List Manager consists of either one or two main panes depending on whether or not the Discover button has been clicked The view above shows a typical Ccn Data Point List Manager view The New and Edit buttons are not unique to the Ccn Point List Manager and are explained in the Niagara AX User s Guide in the Driver Architecture section The Match button is not used for the Ccn driver The Discover button does implement functionality that is unique and tailored to discovering Cc
57. oxy Shadows the behavior of the CCN Output Point under a CcnPicTable CenDataTable CcnDataTablewithTimeSchedule CcnFidTable or CcnFidTablewithTimeSchedule For more clarity on CCN hierarchy refer section 6 CCN ARCHITECTURE of this document NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 2 Niagara AX platform The CCN driver functions either on Windows operating systems starting with Window 2000 Service Pack 3 and beyond or on QNX operating system This means the station must run ona Win 32 based platform such as a JACE NXS or NX AX Soft JACE or a PC especially licensed for the CCN driver or in hard JACE like JACE 2 4 or 5 and 6 series controller Note This driver supports the single CcnNetwork trunk per station 3 Quick Start This section briefly describes how to start with Niagara AX CCN driver e Create a station from Niagara workbench and do the following e Open the ccr palette and find the CCN Network object e Paste a CcnNetwork object under the drivers node in your station From CCN network s Cen Network View edit the bus and element ranges Enter the correct comm port into the field Comm Port Note User should enter only the available ports on a JACE e Open the CenDeviceManager view by double clicking the CcnNetwork object just added to the station o Click the Discover button to dis
58. r Version No 1 0 User Manual Date 11 11 2010 4 Operating Modes in CCN The CCN Driver supports one of two operating modes The default mode must have feature ccnl in the license file For the Extended mode the license feature must include both cen and cenl in the license file The Extended mode driver is not offered for sale at this time cenl cen standard license cen cenl ccn extended license Here s the major difference between the Standard and Extended versions of the CCN driver CCN Standard license feature cenl Read write force auto of display table entries Read write set point table entries Read write time schedule table entries Discovery learn create support for display set point time schedule tables Upload download support for display set point time schedule tables Alarm handling display and logging Broadcast date time Broadcast acknowledger Alarm broadcast acknowledger support Device status support CCN Extended license feature ccn All the above plus Additional support for Read write force auto maintenance table entries Additional support for Read write configuration tables Additional support for Discovery learn create support for maintenance and configuration tables Upload download support for maintenance and configuration tables 5 Configure CcnNetwork To add and configure the CcnNetwork perform the following main tasks
59. rue will be learned in the discovery process The table groups which are selected as false will not be learned in the discovery process NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 _ Is Enhanced Version _ Status Display _ User Configuration _ Maintenance _ Service Configuration _ Set Points _ Time Schedules _ Alarm History _ Holiday Figure 12 Table Group selection from CcnDevice Property sheet OU Ou afis s His Hs G MG Hc O NE Following are the Table Groups support by a FID type device J Status Display true 3 Set Points ggg cig CE PIC UI G 3 Time Schedules _ Holiday true 9 6 CenDevice Actions Ping Pings the Ccn device and updates device ping status property Upload A CcnDevice s CcnPicTables CcnPocTables CcnDataTables and CcnFidTables can be uploaded The upload command is available as an action on the CcnDevice When invoked a list of CcnTables blocks are uploaded and all Station resident data is updated to match that which was retrieved from the field device Download A CcnDevice s CenPicTables CcnPocTables CenDataTables and CcnFidTables can be downloaded The download command is available as an action on the CcnDevice When selected each non real time table s value blocks are constructed from the Station resident
60. s is required It is not recommended to leave tunneling enabled just in case one might someday wish to tunnel a ComfortWorks Tunnel Helper component which contains tunnel related properties as mentioned below Normally set to False setting to True will enable a B character to be displayed in the diagnostic output every tunnel receive cycle Normally set to False setting to True will enable a U character to be displayed in the diagnostic output every tunnel transmit cycle Selects whether tunnel receive debug is turned on or off If set to True protocol specific debug text will be generated and sent to the administrator console window whenever tunnel data is received by the JACE from a ComfortWorks Selects whether tunnel transmit debug is turned on or off If set to True protocol specific debug text will be generated and sent to the administrator console window whenever tunnel data is transmitted to a ComfortWorks from the JACE Version No 1 0 Date 11 11 2010 NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 tunnelRxRetryCount tunnelRxRetryTimeout ms lowLevelDebug lowLevelDebugMask commPort HostbaudRate NIAGARA AX CCN Driver User Manual When the JACE sends tunnel data to a ComfortWorks it expects an acknowledgement of receipt from the ComfortWorks In the event that the JACE sends tunnel data to a ComfortWorks but does not receive any such ack
61. table based view where each row represents a unique point When building a device in the station you use this view to create edit and delete point level components Below is an example Cen Fid Point List Manager View for discovery and adding points to station database The Cen Fid Point List Manager consists of either one or two main panes depending on whether or not the Discover button has been clicked The view above shows a typical Cen Fid Point List Manager view The New and Edit buttons are not unique to the Ccn Fid List Manager and are explained in the Niagara AX User s Guide in the Driver Architecture section The Match button is not used for the Cen driver NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 The Discover button does implement functionality that is unique and tailored to discovering Ccn points By clicking the Discover button the learn mode of the manager is invoked the panes will be split and a discovery table will be displayed in the top pane The progress of the discover points process can be viewed from learn status from that particular table s property sheet Once the discovery job is complete the top half pane of the point manager will display a table of points discovered O Cen Learn Fid Points Discovered Database Name
62. tation database NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 The Ccn Table Manager consists of either one or two main panes depending on whether or not the Discover button has been clicked The view above shows a typical Ccn Table Manager view The New Folder New and Edit buttons are not unique to the Ccn Table Manager and are explained in the Niagara AX User s Guide in the Driver Architecture section The Match button is not used for the Ccn driver The Discover button does implement functionality that is unique and tailored to discovering Ccn tables By clicking the Discover button the learn mode of the manager is invoked the panes will be split and a discovery table will be displayed in the top pane The progress of table discovery can be viewed from learnstatus property from Ccn Table Manager Once the discovery job is complete the top half pane of the Ccn Table Manager will display a collection of tables discovered see following figure Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help e gt 0 D Ebbe ADI N max Raia o My Host ie10dtx66qvb1s Station ccnstation Config XS Drivers E CenNetwork CC6400 e Points l O Cen Learn Tables Discovered Doom E
63. types Output Point defined by 11 Hand 12H applies to field index and field name forcible points in the table An Output Points is one that is forceable NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver User Manual Version No 1 0 Date 11 11 2010 Or The user can select the Force and Auto commands Models a single non forceable Output Point defined by field index and field name in the table A Non forceable Output Point is one that is not forceable but is settable The user can select the setValue command under CcnPicTable types 10H and 13H or 17H under CcnDataTable types that are under CcnPocTable types 14H 16H or 18H CcnFidOutputProxy Models a single Output Point defined by field index and field name in the table An Output Points is one that is forceable The user can select the Force and Auto commands under CcnFidTable types 501H 17 1Creating and Configuring the CcnObject A CcnObject can only be added during the CcnPicTable CcnDataTable s or CcnFidTable PointListManager addition process 17 2 Ccn Object Properties fieldindex ranging from 0 59 CcnPicTable and CenDataTable can have up to 60 points with field Index Fid IO Points Tables can have up to 64 points with field Index ranging from 0 63 Fid Set point Tables can have up to 4 points with field Index ranging from 0 3 Fid Time
64. w NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 The New and Edit buttons are not unique to the Cen Point List Manager and are explained in the Niagara AX User s Guide in the Driver Architecture section The Match button is not used for the Ccn driver The Discover button does implement functionality that is unique and tailored to discovering Ccn points By clicking the Discover button the learn mode of the manager is invoked the panes will be split and a discovery table will be displayed in the top pane The progress of the discover points process can be viewed from learn status from table s property sheet Once the discovery job is complete the top half pane of the point manager will display a table of points discovered Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help eco ft DT Atal Ss DN he x 10 aa T cce e jo Station ccnstation Config SG RTCCNOOC Q Ki Cen Learn PIC Points Discovered L cc 400 Field Name D Alarm Source Info Points TIMEBCST UserConfiguration PE ELEPHANT E TIGER apaptoic H abcdefa DLSTRADY Fa cmatuzep DLSTPMON i fl sensor DLSTPDOW Py cvrouozc fa D b Database Name Description Out Units Enum Field Status F
65. w where each row represents a unique device When building a network in the station you use this view to create edit and delete device level components NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 m NIAGARA AX CCN Driver Version No 1 0 User Manual Date 11 11 2010 Below is an example Ccn Device Manager view for discovery and adding devices to station database Niagara Workbench File Edit Search Bookmarks Tools Window Manager Help e o 0 O8aB e BeB XY hax IR Q Ha El My Host ie10dtx66qvb1s Station ccnstation Config Drivers E CenNetwork x Nav o Cen Learn Devices L x u Network x Discovered EB My Host ie10dtx66qvb1s de My Modules E My File System Platform A Station censtation B Config amp Services ZB Drivers ZB NiagaraNetwork SI E Files ZR History 199 63 42 169 j Database 199 63 42 183 Name Bus No Elem No Palette KO dF L CenDevice CenTableGroup Device Type Status Health Device Status Figure 5 CCN device discovery from Device Manager The Ccn Device Manager consists of either one or two main panes depending on whether or not the Discover button has been clicked The view above shows a typical Ccn Device Manager view The New Folder New and Edit buttons are not unique to the Ccn Device Manager and are explained i