1. QVIS ACS 001 Biometric Scanner Installation Guide Version 1 0 Date Oct 2013 About this Guide This guide provides actual installation instructions only For information regarding user instructions please refer to ACS 001 User Manual QOIS LU em Content NS Sim Conflguratlon meeosseceee neenon rna ncn nn n tren eenrncnuc ies IN 1 1 1 Views of operalien panel gn Lssirli im qme ERES 1 1 2 The illustration of system construction seeeeeseessse 2 1 3 The sketch map Of communication eeseeeseeeeesss 3 P Installalion sees pue poco ua uL 4 Aa Doo sensor connecti l M cane sec ES e mt 6 2 2 Exit buttO Wagen ESuOn 97 ues nnne 6 2 3 Time Ring connection Jg 499 9 7 7 24 Deer ioceennection 25 9M gg NE 8 25 Etherneteennelion Sif 085 neeipuiincn 12 2 6 RS232 connection qe Pil 18 2 7 RS435 coppSSllup gps Los 14 2 8 Wiegand Output Connection o ea e a 15 2 9 Power Connection ua ogee REL ae 16 3 Others m MR EB um cn T 17 9 1 KEN ey ee m cUm 17 3 2 Ant disiTr miles PUTLOn 2 8 diem m 18 3 3 U flash disk USING emm 18 3 4 Rege Battery aa a nn lt r 19 I
2. WDO WD1 GND Power connection 12V GND 69 C 6 5 9 3 O Power TCP IP USB ATS a alei izi lillzielalaisizisejial o zloll amp lzelsieixiollie2ieizxlx alaizlizi4 ZIS IZ A O alZ S 2 IFlOl e a S 219 21 lans 4 O Copyright Qvis All documentation rights reserved 3 QUJ S Installation Guide V1 0 The definition of terminal connections From left to right ur Connect to Cable Bell NO terminal COM Connect to Cable Bell COM terminal Tie up together Connect to Cable Bell NC terminal 4 Sens Connect to Door sensor Or Tieu For Door sensor and release button together EP Connect to Release button n Connect to Lock NC terminal COM Connect to Lock COM terminal Tie up 1 together 9 NC1 Connect to Lock NO terminal Connect to RS485B Tie up Connect to RS485A together 12 GND Connect to RS232 and Weigand GND Tie up D Connect to Power GND Tie up Connect to Power 12v together 5 O Copyright Qvis All documentation rights reserved QOIS a sa 2 1 Door sensor connection The door sensor is used to detect the door open close state The terminal use the door sensor to monitor the door to see if it there has been any unauthorised entry If the sensor detects any unauthorised entry then it will output an alarm signal moreover terminal can trigger a prompt warning if the door is not closed tightly 2 2 Exit button connection The exit button is installed fo
3. Copyright Qvis All documentation rights reserved 3 QUJ S Installation Guide V1 0 1 System Configuration 1 1 View of operation panel LED light Touch screen Fingerprint Sensor Camera Baseline Vasi EN A i Battery slot lt BN At T i J Power TCP IP USB Loudspeaker I O Copyright Qvis All documentation rights reserved 3 QM S Installation Guide V1 0 1 2 The illustration of system connections TCPAP Bell Button N USB 2 Copyright Qvis All documentation rights reserved Installation Guide V1 0 1 3 The sketch map of communication 1 Fingerprint machine directly connects with PC via RS232 or TCP IP TCP IP or RS232 RS485 semn PC RS485 Switch RS232 a TCP IP 3 Copyright Qvis All documentation rights reserved QUE uec 2 Installation Caution Do not connect peripheral equipment after the device has the power turned on to it otherwise it is possible to badly damage the device Please follow instruction to connect peripheral equipment Door sensor connection Sensor GND Exit button connection Button GND Alarm connection NC2 COM2 NO2 Door lock connection NC1 COM1 NO1 Ethernet connection RJ45 1 RJ45 2 RJ45 3 RJ45 6 RS232 connection 232T 232R GND RS485 connection 485A 485B Wiegand output connection
4. and stable Ensure the wiring is correct For the strike lock and electromagnetic lock you should pay attention to the positive and negative terminal connections The unused bare end of wire should be cut off and have insulating tape to wrapped around it The delay time of strike lock is adjustable according to different conditions Electric lock selection it is better to usea strike lock for a two direction opening glass door opens to inwardly or outwardly For a single way opening wood door we recommend using a magnetic lock The magnetic lock is also called an electric magnetic lock The magnetic lock is more reliable than the strike lock but the strike lock is much safer than the magnetic lock In a residential setting it is better to use strike lock and magnetic force lock The electric control lock gives out a higher noise the electric control lock is commonly used in building communication Now there is are soundless electric control locks available which are able to be applied Please be aware that the lock is made of iron and easy rust so you must avoid exposing it to water or harsh outdoor conditions 8 O Copyright Qvis All documentation rights reserved 3 QUJ S Installation Guide V1 0 Connect with electric lock The Normal Open lock is open when the power is on The biometric scanner supports both kinds of lock at the same time The lock connection method changes with the type of lock For NO lock the NO terminal wil
5. ge2300 times 20 O Copyright Qvis All documentation rights reserved 3 QUJ S Installation Guide V1 0 Notice There is a danger of the battery exploding leaking running very hot fire physical damage if you don t read the notice carefully 4 Do Not throw batteries into a fire A Do Not use battery if ambient temperature is above 50 C A Do Not inverse polarity connection A Do Not put the battery into water or let it to get wet Do Not use and store battery near a heat generating machine such as a radiator or heater A Do Not usea wire or other metal to short the positive and negative terminal 2i Copyright Qvis All documentation rights reserved
6. l be used for NC lock the NC terminal will be used This access control machine is powered by DC12V and a working current of 400mA If the lock s electric power is DC12V and the working current is less than 1000mA the fingerprint machine and lock are able to be powered together by one adapter please refer to table 1 2 on the next page In the following three cases we recommend that fingerprint machine and lock are powered separately 1 The working voltage of the lock is DC12V but the current difference of the fingerprint machine and the lock doesn t exceed 1A 2 The lock voltage is not DC 12V 3 The distance between lock and fingerprint machine is too far 9 O Copyright Qvis All documentation rights reserved ODISSE NO LOCK Picture2 power by one supply 10 O Copyright Qvis All documentation rights reserved 3 QM S Installation Guide V1 0 Lock Power SX ri NC LOCK EOS dE Pe DC12V Ag A f fe A y fa V Y EA hd Picture 4 The terminal and lock powered by independent adapters ll O Copyright Qvis All documentation rights reserved QM S Installation Guide V1 0 2 5 Ethernet connection The terminal provides two ways to connect via Ethernet 1 The terminal connected to the PC through a cross cable IP 192 168 1 100 IP 192 168 1 101 Mask Sub Mask 255 255 255 0 255 255 255 0 rmm iFace 2 The terminal connected tothe PC througha netwo
7. nication is over 90 meters in order to reduce the interference caused by the long distance it is suggested to use the cable with shielding and connect the shielded cable to the SGND terminal 15 O Copyright Qvis All documentation rights reserved 2 9 Power Connection The device s working voltage is DC12V with a working current of 900mA and a standby current 50mA This is how to connect the power 1 Terminal connection make sure the connection as like the diagram Don t connect the poles in reverse 2 Slot connection Insert the plug of DC12V adapter into the power slot directly Power Slot DC 12V Terminal connection Slot connection 16 O Copyright Qvis All documentation rights reserved 3 Other functions 3 1 Reset Due to operational error or other errors occuring from usage which has lead to the machine not working you can restart the machine through reset button Take a small tool which has a diameter of no more than 2mm 2 Find the reset mark saying res a small hole on the side of device see the following figure below 3 Use the tool to press into the hole then pull it out The machine is able to restart Reset button 17 Copyright Qvis All documentation rights reserved 3 QUJ S Installation Guide V1 0 3 2 Anti dismantle button The Anti dismantle button is on the middle of the device itis located on the back cover and wo
8. r open door operation When the switch is pressed closed the door will open The maximum distance from ground to exit button bottom is approximately 1400mm Make sure that the exit button position is aligned correctly upright and the connection is accurate and reliable the unused exposed end of cable should be cut off and insulating tape should be used to cover it Pay attention for any electromagnetic disturbances obviously clues will be from any under par performances from other electrical devices near by Door Sensor Button Power Supply 6 O Copyright Qvis All documentation rights reserved 3 QUJ S Installation Guide V1 0 2 3 Time Ring connection Connect the electrical bell to the fingerprint machine when person s arrive at the appointed time the fingerprint machine will send signal to trigger relay The terminal supports both Normal Open bells and Normal Close bells at the same time Normal Open bells e VN Bio scanner i i qq T ed E I Bell Power supply Power supply 7 Copyright Qvis All documentation rights reserved QUJ S Installation Guide V1 0 2 4 Door lock connection What type of door lock to install depends on the type of lock and install location The internal resistance which comes from long distance transfer should be taken into consideration when selecting the electrical power cable The door lock should be installed well enough to be reliable
9. rk and HUB which creates a local network Switch 12 O Copyright Qvis All documentation rights reserved 3 QM S Installation Guide V1 0 2 6 RS232 connection The terminal connected to the PC using the RS232 Note Do not upload or download facial module through RS232 because the large amount of data will effect the transfer speed iFace PC Serial Port 13 Copyright Qvis All documentation rights reserved 2 7 RS485 connection The terminal connected to the PC through RS485 Note Don t upload or download facial module through RS485 because the large data will effect the transfer speed m a 2 485A A 485B h 485A 485B 4 RS485 t ae RS485 Switch EB e E fH B e I RS232 14 Copyright Qvis All documentation rights reserved 3 QUJ S Installation Guide V1 0 2 8 Wiegand Output Connection The device has a Wiegand output function that can connect to the majority of access controllers on the market at this time it is used as a reader Notes 1 The distance between device and access controller or card reader should not be over 90 meters If a longer distance is needed or there is interference in operational environment please use the Wiegand signal delay 2 To ensure the stability of the Wiegand signal the device must share the GND with controller or Weigand reader 3 If the distance of Wiegand output or 485 commu
10. rks by pressing the anti dismantle button in When the device is being dismantled the button will be released and the machine it will send a alarm signal through the terminal Anti dismantle button 3 3 Using the USB U Flash disk 1 There is a mini USB port please see figure circled on the next page 2 The USB port can be used to upload and download data to the U disk 18 Copyright Qvis All documentation rights reserved ow Lem USB Port 3 4 Reserve Battery Working principle Before use make sure the reserve battery is installed properly Whenever using the power supply or reserve battery you need to press the power key to turn on the terminal In its normal state When the power cut down the reserve battery will switch into the discharge state to power on the terminal In power off state when the power cut down the reserve battery will not switch into the discharge state to power on If you want to power on the terminal you need press the power key to turn on the terminal 19 Copyright Qvis All documentation rights reserved ER D Power key Technical parameter Charge time Less than 4 H Discharge More then 5 5 H NO 7 Working Que ES ANO Relative 10 90 6 TIR otoring Please store the battery when the discharge environment capacity is full and the environment is 20 C 5C Cycle age Cycle times of charge and dischar