1. Quick Start Guide T16 ISO Stand Alone Mode TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk DOCUMENT CONTROL DETAILS QSG Quick Start Guide Axxin T16 ISO Platform CUSTOMER CONTACT DOCUMENT APPROVAL REVISION HISTORY REVISION DESCRIPTION AUTHOR DATE 1 First Release 02 December 2013 General Release CONTENTS TDV Ay OU uri A A ti 3 SU AS aia E EE EE E E T EE EE 4 A A E E rn EA E 5 Aa 5 due NeW OS asian oi ici dica basayvndda 5 SA o PP T og NUIT NES DOV CO sear a see nee a E E E A AA EN 8 P EDOT TREE 8 A PI Pe OR E A a A n aE e E aN deN reei R 9 A UF NEU E E EE E E EEE 9 AZ AQ Tato USE oni eiea E Na ia a a a aa e EEE 9 5 Instrument Specifications cee cccecccceeeeceeee ce eecee cece cece cess nese cess eseeeeseeeeseueeeeueeseuseseusesaeeseaeesaeessueessueesaueesaaegaes 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk NOTE 1 Please note that this is a Quick Setup Guide only Please refer to the user manual for complete instructions on the use of the T16 ISO device 1 DEVICE LAYOUT a5 LCD Color Touch Screen Dynamic Graphics Workflow Management Lid Step by Step User Guide Y Results Display ge Easy to C
2. and the test number will be used on the next run test Close Lid The device lid is required to be closed to initiate the start of a test but once the test workflow has started lid open and close events will be recorded in test results JSON file for review The T16 ISO Instrument will display the current temperature and the test temperature set in the Test Type Once the Temperature is set the test can begin 3 54PM MAY 11 2012 T 001 Test Type Example Test A Name test AAOC FAT nmrin FAEAESESERAESNET PPS 423 space 3 55PM MAY 11 2012 Test Type Example Test A Name test Loading ABC ABC ABC ABC ABC ABC ABC ABC 1 2 3 5 6 7 8 asc ABC ABC ABC ABC ABC ABC ABC 4 9 10 11 12 1 14 15 16 AUTO TESTING 10 24 AM 27 SEP 2012 T 001 Test Type test47degrees Name abc Warming up Current Temperature 49 8 C Set Temperature 47 0 C 6 of 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk If the Test Type required the Instrument lid to close during TESTING 10 23 AM 27 SEP 2012 test then the instrument will not initiate testing until the lid is T4001 Test Type Demo Test closed by the user Name abc Instrument Ready Close Lid to Start Once the 3 55PM MAY 11 2012 v sample tubes have been inserted Test Type Example Test A v
3. the test name has been entered v all desired Sample IDs have been entered v the T16 ISO is at temperature v and the device lid is closed The user is ready to start a test START TEST The Waiting workflow item displays the timer countdown in Y 11 02AM MAY 14 2012 which the sample is held at temperature 11 02 28AM 14 05 2012 Example Test A Waiting Waiting E 3 Seconds The Reading workflow item indicates that FAM HEX and 3 55PM MAY 11 2012 ROX readings are being taken for the tubes and the 3 55 38PM 11 05 2012 channels selected in the Test Type ia Reading Reading PS 3 3 Results The following results are possible for the T16 1SO Negative Result Instrument tests Positive Result Invalid Result If a Sample ID is not entered for a Tube no result me No Sample ID will be displayed for that tube instead the No Sample ID icon will be displayed A warning underneath the Sample IDs indicates when no data is entered and because of this no result can be displayed 7 of 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk The results screen displays the test results for each of the tubes tested This information can be printed in a test report by selecting the Print icon To start a new test by selecting the New Test icon To view more r
4. B ADMIN SETTINGS memory key connected to the instrument IMPORT amp EXPORT cluding FUNCTIONS Export Test Results e Export Device Log e Import Test Types e Import Customization Profile Export Test Results Export Device Log Import Test Types Import Customization Profile 8 of 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk 4 MENU STRUCTURE 4 1 User Menu HOME e E e e e TESTMENU VEWAL Q ABOUT THIS DEVICE RUNTEST SEARCH FILTER Q HELP INFORMATION PRINTRESULT GO TO TEST NO Q AUDIO Q BRIGHTNESS Q PRINTER SETUP__ Q REMOTE MODE Feature is password restricted ADMIN SETTINGS 4 2 Administrator User SETTINGS Admin User has the same access to Y ADMIN SETTINGS these screens as the standard user _TIME amp DATES NETWORK _IMPORT amp EXPORT FUNCTIONS ll PARKOPTICS 6 _RESET TO FACTORY DEFAULT FACTORY SETTINGS 6 Feature is password restricted 9 of 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk 5 INSTRUMENT SPECIFICATIONS Number of Tubes Configured for up to 16 tubes Assays Supports a test types defined on the AX ISO D
5. esktop application Measurement Technology Fluorescent 3 Channel FAM HEX ROX Colour Touch Screen 3 5 Simple workflow management Ease of use Colour icon driver menus and prompts Communications Cable Ethernet for Data Transfer USB Port for data export barcode reader and printer Mini USB Port for Laptop connection Data storage Up to 99 results configurable Power 12 V DC from external AC DC supplied plug pack Battery power optional DC Voltage fluctuation 10 DC Current consumption 12V DC 3 0 Amps Dimensions 380 mm L x 122 mm W x 139 mm H 14 0 L x 4 8 W x 5 4 H Weight 1 95 kg 4 1 Ib Lifetime 3 year calibration life 5 year instrument life Printers Postscript 3 Network Printer Operating Environment Indoor Use 10 C to 30 C 10 to 70 RH non condensing 0 to 2000m altitude Pressure 0 763 bar 2000m to 1 01 bar sea level Pollution category 2 Minimum light conditions of 100 LUX Maximum light intensity of 5 000 LUX Storage Environment 0 C to 45 C 20 to 70 RH non condensing for at least 7 days Pressure 0 763 to 1 01 bar O to 2000m altitude Maximum duration 1 month cumulative Cleaning Isopropyl Alcohol IPA or 10 bleach solution on a damp lint free wipe No free liquid 10 of 10
6. esults information about a specific tube result by selecting that tube from the onscreen graphic In the examples bellow the Tube 6 Negative result was selected The Detailed Results screen displays the Sample ID and result for that tube By selecting the Graph icon the user can view a graph for that tube Selecting Print will print a summary of this screen Selecting the graph icon displays the data points recorded over time as the assay develops Selecting Print will print a summary of this screen 3 4 About this Device oS TESTING 11 04AM MAY 14 2012 T 001 3 44 05PM 24 02 2012 Test Type Example Test A Name test1 Finished 7 00 7 3 44 05PM 24 02 2012 Test Type Example Test A Name test1 Finished Sample ID abc06 Tube 6 Result zt BEEN 8 Sample ID abc06 Tube 6 min 0 2 6 8 HOME The About this device screen gives information SETTINGS about the T16 ISO Instrument Device including ABOUT THIS Instrument Name DEVICE Instrument ID e Application Version IP Address e Mac Address e OS build Version e Kernel Version 10 12 x ABOUT 11 35AM MAY 14 2012 Instrumnet Name T16 1SO Instrumnet ID CB8EC413 Application Version 1 3 0 0 IP Address MAC Address OS Version 0 0 Kernel Version 0 0 0 3 5 Export HOME The Data Export function allows the admin PARO aL Nana SETTINGS user to export specific files to a US
7. evice for use 4 of 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk 3 RUN A TEST 3 1 Home Menu HOME 3 51PM MAY 11 2012 Connect unit power supply to T16 ISO The T16 ISO Instrument will start power up sequence once the user engages the power switch The landing page is the Home Menu The Home Menu screen provides the following e Testing e History e Settings 3 2 New Test HOME TESTING Select the Testing icon on the home screen TESTING 3 52PM MAY 11 2012 Select Test Type to view the list of the currently available test types To change assigned test press the box again to make new Test Type selection Example Test A Select the test type you wish to run from the onscreen test TESTING 3 52PM MAY 11 2012 apts NOTE 4 Test Types created on the T16 ISO desktop Example Test B application must be imported onto the device Example Test C Refer to D004829 QSG Quick Start Guide Example Test D Desktop Software Axxin T16 ISO Platform for Example Test E more information Example Test F Once an appropriate test has been selected from the list of Test types installed on the T16 ISO Instrument then select OK to navigate to the next test step Enter a Test Name using the onscreen keyboard The user enters a Test Name as an add
8. itional information field as a reference item to search and identify tests at a later date JL MODULE lalslolelelallsl lc 5 of 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk The test screen indicates which tubes need to be inserted for the assigned Test Type Where a Tube is not required an empty black tube location is displayed In this example all 16 tubes are required for testing Tube locations with no Sample ID entries will remain blank until a Sample ID is entered and saved Each tube requires a unique Sample ID Enter a Sample ID by selecting the tube location from the onscreen graphic and using the onscreen keyboard to input the text field Select OK to save text input Select Cancel to navigate back without saving changes Sample IDs If the Test Type requires Sample ID entry this must be done using the Instrument s touch screen display prior to testing If an alpha followed by a numeric sample id is entered for example ABCOO the information can be auto filled y Once all Sample IDs have been entered it is now possible to start the test Insert the samples into the T16 ISO tube bed Select OK to proceed Select Cancel to cancel current test NOTE 1 Note that if the test is cancelled the test number T8 will not be recorded in the test results
9. lean Fa Power Button Tube Locations 1 to 16 200 uL format Minimum 50 pL Sample Volume Figure 1 Front View gt Communications f LISB connection EthemetConnection el Mini LISB connection ISB Comms Connector Power Connector External 12 v DC Multi adaptortor world use p P Fluorophore Module System Speaker Replaceable Module Audio Tones channels Prompts Figure 2 Back View 3 of 10 TwistDx Limited Minerva Building Babraham Research Campus Babrahan Cambridge CB22 3AT UK Tel 44 0 1223 496700 Email techsupport twistdx co uk www twistdx co uk 2 SETUP GUIDE Inspect the T16 ISO device packaging for any obvious signs of damage during shipping prior to opening ap Unpack the entire contents of the package and inspect all items for damage Place the T16 ISO device on a stable level bench in a clean office or lab type environment Unplug the power supply contents Configure the power supply for your region 3 Connect the 12V power supply to the unit mE Connect the power supply to mains power m Mi NOTE 2 An Ethernet cable is required to connect the T16 ISO device to a facility network for network printing and to sync to network date time settings NOTE 3 A USB key is used for export and import functions on the T16 ISO device The SanDisk Cruzer Blade brand flash memory key formatted for FAT32 with only 1 partition is the suggest USB key d