1. 1394 complaint six pin to six pin FireWire cable is used to connect the PHANTOM Omni device to the IEEE 1394 compliant six pin FireWire port on your computer The cable must be used with the two attached ferrite beads please do not remove them Two extra ferrite beads to be used on an optional user supplied second FireWire cable Universal Power Supply The power supply can be used on any standard circuit an AC input of 50 60 Hz and 100 240 VAC using the supplied power cord The power supply must be used with the attached ferrite bead please do not remove it Power Cord The power cord connects the Universal Power Supply to the wall outlet PHANTOM Omni User s Guide 1 1 GETTING ACQUAINTED The PHANTOM Omni Haptic Device e Wrist Rest The gel filled wrist rest helps to support your wrist and hand while using the PHANTOM Omni If any items are missing please call SensAble Technologies at 1 888 SENSABL US only or 1 781 937 8315 US and outside the US Important Do NOT throw away the packaging materials If for any reason you need to ship the device in the future you will want to reuse these materials to reduce the risk of damage to the device For instructions on how to properly pack the device see Appendix E PHANTOM Omni Packaging Instructions The PHANTOM Omni Haptic Device The SensAble Technologies PHANTOM product line of haptic devices makes it possible for users to touch and manipulate virtual objects T
2. 7225 Outside the United States 1 781 939 7444 PHANTOM Omni User s Guide 19 A CUSTOMER SUPPORT 20 PHANTOM Omni User s Guide Appendix B Troubleshooting This section provides tips for correcting some common problem encountered with the PHANTOM Omni device If after following these steps you cannot resolve the problem please contact customer support see Appendix A Customer Support The PHANTOM Omni s light located in the inkwell does not come on at all The light on the PHANTOM Omni device should be on if it is receiving power Check that the power supply is plugged into a working outlet the light on the power supply should be green if it is Then check that the connection between the power supply and the PHANTOM device is made correctly The PHANTOM Omni blinks on and off A blinking light means your PHANTOM Omni device may not be properly calibrated This can happen if you unplug it To correct this situation place your stylus in the inkwell During this process the light should turn a solid blue which lets you know you are ready to resume working If the light does not turn solid blue please contact Customer Support The PHANTOM Omni stylus and the cursor in my application seem to be out of sync This indicates that your PHANTOM Omni device may not be calibrated properly This can happen if you unplug it To re calibrate the device place the stylus in the inkwell The light on the PHANTOM Omni device should tur
3. Omni device Warning SensAble Technologies uses only FireWire components that exceed the IEEE 1394 implementation recommendations If you are considering purchasing a third party FireWire cable please ensure that your selection meets or exceeds these recommendation SensAble is not responsible for any damage that might result from using 3rd party cables that do not exceed these IEEE 1394 implementation recommendations Contact SensAble Customer Support with questions PHANTOM Omni User s Guide 11 2 INSTALLING THE PHANTOM DEVICE Connecting the PHANTOM Omni Device a Connect the supplied FireWire cable into either of the two 6 pin FireWire ports on the back of the PHANTOM Omni device as shown in Figure 2 6 and Figure 2 7 Warning Make sure the connector is facing in the correct direction as shown on the left in Figure 2 7 FIGURE 2 8 Insert the FireWire cable plug correctly into your computer s FireWire card b Connect the other end of the FireWire cable to the FireWire port on your computer Warning Make sure the connector is facing in the correct direction as shown in Figure 2 8 above 12 PHANTOM Omni User s Guide 2 INSTALLING THE PHANTOM DEVICE Connecting the PHANTOM Omni Device 5 After you have connected the PHANTOM Omni device to your computer the the Microsoft Found New Hardware Wizard dialog will appear This may take a few moments Click Next Continue as appropriate for your operat
4. padding b Place cardboard on the bottom of the box c Fit the bottom foam insert into the bottom of the box Wrap the PHANTOM device in the plastic bag Orient the PHANTOM device to fit neatly inside the foam insert You may need to grasp the PHANTOM device by the upper arm the piece with the oblong cutout in order to position it properly DO NOT grab the stylus Gently lower the PHANTOM device into the insert while maintaining alignment of the PHANTOM arm to the cutout Ensure that the PHANTOM device is fully seated by pressing firmly on the PHANTOM Omni label Check to see that the PHANTOM arm is fully seated by carefully pressing on the elbow joint Place the top half of foam insert over the PHANTOM device Next place all the accessories in the box 8 9 Place the power supply power cord FireWire cable and extra ferrite beads into the cutouts on the top of the foam insert Place the cardboard over the insert followed by the foam pad 10 Close the box and tape shut 32 PHANTOM Omni User s Guide Appendix F PHANTOM Omni Specifications Product specifications are subject to change without notice Nominal Position Resolution gt 450 dpi 0 055 mm Workspace 6 4 w x 4 8 h gt 160 w x 120 h x 70 d mm x2 8din Backdrive Friction lt 1 02 0 26 Maximum Exertable Force 0 75 Ibf 3 3 N Continuous Exertable Force 24 hrs gt 0 2 Ibf gt 0 88 N Stiffness X axis gt 7 3 Ibs in Y a
5. produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilisateur de prendre les mesures sp cifiques appropri es PHANTOM Omni User s Guide 27 C REGULATORY NOTICES 28 PHANTOM Omni User s Guide Appendix D Configuring Multiple Devices If you want to use more than one PHANTOM haptic device with your computer you can create as many as 20 uniquely named PHANTOM configurations Each named PHANTOM configuration can refer to a particular system configuration that you use frequently Which device to use is defined by the software application which uses it To create a new PHANTOM configuration use the PHANTOM Configuration Utility 1 From the Start menu select Settings gt Control Panel gt PHANToM Configuration The PHANTOM Configuration window opens On the hardware tab click Add Enter a name to call that device click OK From the PHANTOM model menu select the correct model Click OK nan RO P Dual Configurations The Dual Configuration settings only apply if you want to set up a pair of PHANTOM devices to work in tandem with each other You must have created at least tvo PHANTOM devices as described above before the Dual Configuration tab can be used Once you have created at least two devices go to the Dual Configuration area and select the PHANTOM devices you would like to use in a paired configuration Then enable the check box to turn the dual configuration on PHANTOM Om
6. that shipped with your product Chapter 3 Using the PHANTOM Omni Device describes how to work with the device and introduces you to the physical limits in the device s range of motion PHANTOM Omni User s Guide PREFACE Additionally there are several appendices including how to contact customer support and information for troubleshooting your device Typographical Conventions This guide uses the following typographical conventions directory paths or examples Convention Description Example Italics First use of a new term See the User Manual reference to another document or file lt Italics gt A variable Installed Directory files Bold Keywords actual user input Click Ok Greater Than gt Indicates a menu pick Tools gt Options Courier Identifies code samples Note Warning Calls out important Important information ii PHANTOM Omni User s Guide 1 Getting Acquainted This chapter describes the following The contents of the shipping box The PHANTOM Omni haptic device The proper handling of the device The other contents that were shipped with the device Shipping Box Contents In your shipping box you should find the following The PHANTOM Omni haptic device The PHANTOM Omni User s Guide CD ROM containing application software purchased and the PHANTOM Device Driver and electronic documentation FireWire cable This IEEE
7. Omni User s Guide Preface About This Guide The PHANTOM Omni User s Guide describes the process of installing the required device drivers for your new PHANTOM Omni haptic device and connecting the hardware You will also find information on how to use the device and other information about the device We ve worked extensively to ensure that the PHANTOM Omni device and device drivers install and work smoothly If you experience any problems in the installation or use of your device please contact technical support as indicated in Appendix A of this document Your feedback and input are essential Please do not hesitate to contact us with technical questions and suggestions for improvement Please note if you are installing your device on a non Microsoft Windows OS you will find additional information in a separate document shipped with your product How This Guide Is Organized This guide is divided as follows Chapter 1 Getting Acquainted describes the PHANTOM Omni device and other items that were shipped with the device Chapter 2 Installing the PHANTOM Omni Device describes how to install the software necessary to run this product on PCs under Windows 2000 or Windows XP and how to connect the PHANTOM Omni device to your computer Please note that if you are installing your device on a non Microsoft amp Windows OS you will find additional information about installing the PHANTOM Device Drivers in a separate document
8. PHANTOM USER S GUIDE technologies Copyright Notice 2003 2004 SensAble Technologies Inc All rights reserved U S Patents Pending Community Design No 000168638 0001 Printed in the USA Except as permitted by license no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior written consent of SensAble Technologies Trademarks 3D Touch ClayTools FreeForm FreeForm Concept FreeForm Modeling FreeForm Modeling Plus FreeForm Mold GHOST HapticSound OpenHaptics PHANTOM PHANTOM Desktop PHANTOM Omni SensAble SensAble Technologies Inc Splodge Splodge design and WebTouch are trademarks or registered trademarks of SensAble Technologies Inc Other brand and product names are trademarks of their respective holders Warranties and Disclaimers SensAble Technologies does not warrant that this publication is error free This publication could include technical or typographical errors or other inaccuracies SensAble may make changes to the product described in this publication or to this publication at any time without notice Questions or Comments If you have any questions for our technical support staff please contact us at support sensable com You can also phone 1 888 SENSABL U S A only or 1 781 937 8315 International If you have any questions or comments abou
9. PHANTOM Omni User s Guide 9 2 INSTALLING THE PHANTOM DEVICE Connecting the PHANTOM Omni Device a Insert the round pin from the SensAble supplied power supply into the back of the PHANTOM Omni device as shown in Figure 2 6 Ferrite beads Use the two supplied ferrite beads when connecting a second FireWire cable to the PHANTOM Omni The ferrite beads must be clamped on the user supplied cable as shown This end must be plugged into the 6 pin FireWire connector DC Power Use SensAble supplied power supply only do not substitute another power supply FireWire Cable Use Sens Able supplied FireWire cable only The supplied cable has two ferrite beads that must remain clamped on the cable The end with two ferrite beads must be plugged into the 6 pin Fire Wire connector FIGURE 2 6 Back of the PHANTOM Omni device Warning Do NOT substitute another power supply b Plug the power supply into an available AC outlet For 110 V the AC outlet must be rated for at least 2 Amps for 220 V AC at least 1 Amp 10 PHANTOM Omni User s Guide 2 INSTALLING THE PHANTOM DEVICE Connecting the PHANTOM Omni Device Power supply has a green LED that should light up indicating that the power supply is live If it is not check all of the connections Contact SensAble Technologies if the problem persists 4 Connect the FireWire cable FIGURE 2 7 Insert the FireWire cable plug correctly into the PHANTOM
10. at allows your computer to communicate with the PHANTOM Omni device 2 Connect the PHANTOM Omni device to your computer and power source System Requirements The PHANTOM Omni haptic device requires certain hardware and software components to be able to work properly Intel processor based personal computer A minimum of Pentium II class processor is recommended or select AMD processor personal computer e Add in IEEE 1394 complaint FireWire port See our Website for more detailed information e Windows 2000 or Windows e A hard drive with 30 MB of disk space There are no specific memory requirements however a minimum of 32 MB RAM is recommended for overall system performance PHANTOM Device driver version 4 2 x See the software documentation for PDD requirements for any haptically enabled applications you will be running PHANTOM Omni User s Guide 7 2 INSTALLING THE PHANTOM OMNI DEVICE Installing the PHANTOM Device Drivers e SensAble supplied 6 6 pin FireWire cable or a 3rd party FireWire cable that exceeds the IEEE 1394 implementation recommendations Laptop Users please note that SensAble recommends using a 6 6 pin cable and add in card instead of 6 4 pin See www sensable com for the latest information Installing the PHANTOM Device Drivers The PHANTOM Omni device communicates with the computer through the FireWire port To enable this you must install a software driv
11. ations This digital apparatus the PHANTOM Omni haptic device does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique the PHANTOM Omni haptic device respecte les limites de bruits radio lectriques visant les appareils num riques de classe B prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada 26 PHANTOM Omni User s Guide C REGULATORY NOTICES European Requirements EN 55022 Statement This is to certify that the SensAble Technologies PHANTOM Omni haptic device is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55022 Class CISPR 22 Warning This is a Class B product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse B Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten in welchen Fallen der Benutzer f r entsprechende Gegenma nahmen verantwortlich ist Attention Ceci est un produit de Classe B Dans un environnement domestique ce
12. er called the PHANTOM Device Drivers PDD to control the communication Actual installation procedure may vary slightly from the instructions given here depending on which version of the PDD you are installing and which operating system you are running Instructions are given for Windows XP with exceptions noted for Windows 2000 For installation instructions for other operating systems see the additional documentation shipped with your device or software product or contact customer support Note As with most other software packages you must have administrator privileges on the machine in order to install software If you are unfamiliar with installing software or do not have administrator privileges please have your System Administrator execute the following steps for you To install the device drivers 1 Insert the CD into the CD ROM drive Note If you purchased a SensAble software product your PDD drivers may be found on your software product CD 2 In Windows Explorer locate the drive letter associated with your CD ROM drive and double click it 3 In the CD s directory locate the PHANTOM Device Drivers folder and double click to open it Double click setup exe to begin the installation 5 The InstallShield Wizard will appear Click Next 6 Accept the terms of the license agreement and Click Next 8 PHANTOM Omni User s Guide 10 2 INSTALLING THE PHANTOM OMNI DEVICE Connecting the PHANTOM Omni Device On the Setup T
13. hat there is a defect or a loose connection inside the PHANTOM Omni device DO NOT ATTEMPT TO OPEN THE DEVICE Contact SensAble Technical Support When contacting Support you may be asked to run the PHANToM Test application to help with diagnosis Located in the lt Sensable Install Directory gt Phantom Device Drivers This application can be found in the directory where you installed the PHANTOM Device Drivers The following describe the basic features of this test application which you should be prepared to run Select the PHANTOM device which you want to test Usually this will be Default PHANTOM e Read Encoders The values being sensed for the positions and rotations of the device are dynamically displayed in the window The stylus switch is ON when the user presses the front blue button The presence switch is ON when the user presses the second white button The picture of the PHANTOM Omni should change dynamically as you move the stylus around e Test Forces IMPORTANT Hold onto the stylus when executing this test Move the sliders with your mouse to generate forces which push against your hand X controls force parallel to the table Y controls force up and down And Z controls force in and out 22 PHANTOM Omni User s Guide B TROUBLESHOOTING Test Provides a box which you can feel with your PHANTOM Omni The sides of the box should feel flat and the corners sharp e Quit Quits the test appl
14. he PHANTOM Omni model is the most cost effective haptic device available today Portable design compact footprint and IEEE 1394 FireWire port interface ensure quick installation and ease of use Features e FCC and CE Certified Six degree of freedom positional sensing e Portable design and compact footprint for workplace flexibility e Comfortable molded rubber stylus with textured paint for long term use and secure grip e Removable stylus for end user customization e Two integrated momentary switches on the stylus for ease of use and end user customization e Wrist rest to maximize user comfort e Compact workspace for ease of use e Constructed of metal components and injection molded plastics e Stylus docking inkwell for automatic workspace calibration 2 PHANTOM Omni User s Guide 1 GETTING ACQUAINTED Proper Handling and Positioning of the PHANTOM Omni Proper Handling and Positioning of the PHANTOM Omni Warning Gripping and lifting the PHANTOM Omni device improperly may damage it To reduce the risk of damage please follow the instructions below Handling Calibrating the device The PHANTOM Omni may need to be recalibrated from time to time particularly if it has lost power To calibrate the device place the stylus in the inkwell and start your haptically enabled application The indicator light on the PHANTOM Omni device will be a steady blue when the device is properly calibrated Lifting the device To p
15. ication How do I connect multiple PHANTOM Omni devices daisy chaining To connect more than one PHANTOM Omni device first connect your primary device to your computer following the instructions on Connecting the PHANTOM Omni Device on page 9 Follow the same instructions for the second device but connect the FireWire cable of your second device into the back of the first device rather than your computer IMPORTANT remember to ensure that the connectors are oriented properly to the ports See Appendix D Configuring Multiple Devices for more information PHANTOM Omni User s Guide 23 B TROUBLESHOOTING 24 PHANTOM Omni User s Guide Appendix C Regulatory Notices FCC Notice U S Only The PHANTOM Omni haptic device is classified by the Federal Communications Commission FCC as a Class B digital device Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television recept
16. ing system For Windows XP Users 6 At this point a dialog will appear informing you that components of the software have not passed Windows Logo testing This testing is currently underway YOU CAN CONTINUE THE INSTALLATION PROCESS WITHOUT HARMING YOUR SYSTEM Click Continue Anyway each time you see this dialog 7 Click Finish to complete the install process Continue to the next chapter to get familiar with using the PHANTOM Omni device Windows 2000 users 6 You will see the Install Hardware Device Drivers window indicating that it 10 11 has found the SensAble Technologies device Choose Display a List of the Known Drivers for This Device then click Next If you do not see this message check to ensure that the device cables are plugged in correctly and that if applicable your FireWire card is installed properly In the Select a Device Driver window you will see Support for SensAble Technologies 1394 PHANTOM Devices Make sure Show compatible hardware is selected and click Next On the Start Device Driver Installation window click Next If you have already installed the PDD on the Insert Disk dialog click OK On the Files Needed dialog browse to lt SensAble Install Directory gt PHANTOM Device Drivers 1394 PHANTOM_1394 sys Click OK You should see a window that says Completing the Found New Hardware Wizard Click Finish and the process is complete Continue to the next chapter
17. ion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment under FCC rules The following information is provided on the device covered in this document in compliance with FCC regulations Product Name PHANTOM Omni Model Number 02350 Company Name SensAble Technologies Inc PHANTOM Omni User s Guide 25 C REGULATORY NOTICES NOTES Any changes or modifications to the hardware not expressly approved by SensAble Technologies could void the user s authority to operate this equipment Use of FireWire cable with a ferrite bead is required to comply with the Class B limits of Part 15 of FCC rules This cable is provided with the hardware additional cables are available directly from SensAble Technologies This device is to be used with the SensAble supplied power supply only Replacement power supplies are available directly from SensAble Technologies Canadian Requirements Canadian Department of Communications Radio Interference Regul
18. mits of the Device FIGURE 3 2 Micro movements Showing movement at the stylus 4 Holding the stylus with one hand gently rotate the stylus back forth pivot it up down and left right Again when you encounter a physical limit do not force it Now you should have an understanding of the range of motion of the PHANTOM Omni device and where its limits are IMPORTANT ALWAYS work with the connected end of the stylus pointing away from you The stylus should always be held as shown in Figure 3 2 NEVER rotate the stylus with the point facing you To become more familiar with working with the device go to the SensAble Dice demo application installed with the PDD and found in the Start gt Programs gt SensAble PHANTOM Omni User s Guide 17 3 USING THE PHANTOM OMNI DEVICE Physical Limits of the Device 18 PHANTOM Omni User s Guide Appendix A Customer Support Warning DO NOT OPEN THE DEVICE There are no serviceable components in the PHANTOM Omni device or power supply Return to SensAble for servicing If you encounter any difficulties you can obtain Technical Support through the following three channels e Ifyou purchased your PHANTOM Omni device from a distributor please contact them first SensAble Technologies Customer Support be reached via e mail at support SensAble com e SensAble Technologies Customer Support can also be reached via telephone n the United States 1 888 SENSABL 1 888 736
19. n a solid blue If the light does not turn solid blue please contact Customer Support When I start an application I get an error This can happen if the device is not plugged in properly or is not configured properly Execute the following steps checking at each point for proper operation 1 Verify power supply Check to make sure the PHANTOM Omni device is plugged in properly The green LED on the power supply will light up if power if the power supply is live 2 Verify FireWire cable connection Make sure that the FireWire cable is plugged into the LOWER port on the back of the PHANTOM Omni device Make sure the other end is plugged into the FireWire port on your computer 3 Verify the settings between your computer and the PHANTOM Omni device PHANTOM Omni User s Guide 21 B TROUBLESHOOTING a From the Start menu select Settings gt Control Panel Within the Control Panel window select PHANTOM Configuration From the device dialog make sure that PHANTOM Omni is chosen as the model d Restart your computer 4 Verify the PHANTOM Device Driver PDD is installed properly a Uninstall the current PDD b Reinstall the PDD c Restart the computer If after following the above you are still unable to start an application please contact SensAble Technical Support I am able to start an application but even though the light is solid green the device behaves strangely when I move it around in a scene It is possible t
20. ni User s Guide 29 D CONFIGURING MULTIPLE DEVICES 30 PHANTOM Omni User s Guide Appendix E PHANTOM Omni Packaging Instructions If you need to transport or ship the device please follow these packaging guidelines to reduce the risk of damage to the device Important Remember the PHANTOM Omni device is a sensitive piece of electronic equipment and must be handled with care Lifting the device by any of the moving parts may adversely affect the unit s performance and risks damaging the device The PHANTOM Omni device has a limited range of motion Forcing the device past these limits risks damaging the device If you have not already done so please review Proper Handling and Positioning of the PHANTOM Omni on page 3 Shipping Checklist Packing Materials You will need the following items to ship the device safely The packaging materials in which the device was originally shipped e 1 Medium shipping box e 1 Set of foam inserts cradles the device e 6 Pieces of foam padding lines the inside walls of box e 2 Squares of cardboard inside bottom and top of box e Thin clear plastic wrapping material Additionally e Packing tape PHANTOM Omni User s Guide 31 E PHANTOM OMNI PACKAGING INSTRUCTIONS Packing the Device and Accessories First package up the PHANTOM Omni device 1 7 If necessary assemble box and arrange cardboard foam padding and bottom insert a Line the sides and bottom with the foam
21. roperly lift the device grasp the base of the PHANTOM Omni unit on both sides and lift as shown in Figure 1 1 DO NOT lift by grasping the stylus The stylus is detachable by design Lifting the unit by the stylus could result in severe damage to the device FIGURE 1 1 Position hands to securely lift the device PHANTOM Omni User s Guide 3 1 GETTING ACQUAINTED Proper Handling and Positioning of the PHANTOM Omni Lifting the stylus out of the inkwell Grasp the end of the stylus and lift UP and then OUT as show in the image on the left in Figure 1 2 Do NOT attempt to pull the stylus straight out as shown on the right FIGURE 1 2 Be sure to lift the stylus in a two step motion Storing the stylus After the device is calibrated the stylus may be kept in the inkwell or left resting on the desk Keep in mind that storing the stylus in the inkwell increases the risk that the device will be knocked over or that the stylus will be damaged FIGURE 1 3 Stylus does not need to be stored in the inkwell 4 PHANTOM Omni User s Guide 1 GETTING ACQUAINTED Proper Handling and Positioning of the PHANTOM Omni Protecting the device from damage It is best to place the unit firmly on the desktop and away from edges to reduce the risk of damage to the device from a direct unintentional elbow hit The stylus is particularly vulnerable to sustaining damage when it is in the inkwell ASIN FIGURE 1 4 To reduce the risk of damage keep
22. s damaging the device Take some time to become more familiar with the physical limits of the PHANTOM Omni before using the device by completing the following steps PHANTOM Omni User s Guide 15 3 USING THE PHANTOM OMNI DEVICE Physical Limits of the Device 16 Grasp the rubber grip of the stylus as you would a pen with the free end of the stylus what would be the non writing end of a pen pointing toward you and the point of the stylus the end connected to the arm pointing toward the unit Using the following illustration as a guide gently move the stylus in all directions to feel the physical limits mechanical stops In steps 2 and 3 you will perform macro movements That is you will move the arm and body of the PHANTOM Omni device In step 4 you will perform micro movements moving the device at the stylus FIGURE 3 1 Macro movements Showing movement of the PHANTOM Omni arm and the body Start with large but gentle movements Move the stylus up down and in out The primary movement will happen in the arm of the PHANTOM Omni device When you reach a physical limit you ll feel one of the device s mechanical stops Don t force the device past any of these stops Next move the device left right The body of the PHANTOM Omni device will pivot until is reaches a physical limit Again do not try to force the device past any of the mechanical stops PHANTOM Omni User s Guide 3 USING THE PHANTOM DEVICE Physical Li
23. t the documentation please contact us at documentation sensable com Corporate Headquarters SensAble Technologies Inc Phone 1 888 SENSABL U S A only or 15 Constitution Way 1 781 937 8315 International Woburn MA 01810 E mail support sensable com Internet http www sensable com Last Updated 17 November 2004 11 01 am P N 02495 R3 Contents Chapter 1 Chapter 2 Chapter 3 Appendix A Appendix B Appendix C Appendix D Appendix E Appendix F ec i Getting Acquainted 1 Shipping Box Contents sse 1 The PHANTOM Omni Haptic Device 2 Proper Handling and Positioning of the PHANTOM Omni 3 Installing the PHANTOM Omni Device 7 System Requirements 2 7 Installing the PHANTOM Device Drivers 8 Connecting the PHANTOM Omni Device s 9 Using the PHANTOM Omni Device 15 Working in 3D Space eer metere res 15 Physical Limits of the Device 2 2 15 Customer Support _ 19 Troubleshooting 5 ccce isnt carae nain ania 21 Regulatory Notices 25 Configuring Multiple Devices 29 PHANTOM Omni Packaging Instructions 31 PHANTOM Omni Specifications 33 PHANTOM Omni User s Guide PHANTOM
24. the device out of harms way Pay extra attention if the stylus is stored in the inkwell Reassembling the detachable stylus The stylus is detachable for future use If the stylus is detached for any reason reassemble it by aligning the blade on the shaft with the slot in the stylus and inserting it till it snaps in place as shown in Remember Do NOT attempt to lift the unit or relocate it on the desk by pulling on the stylus This may this may result in severe damage to the device FIGURE 1 5 Align the blade and shaft to reassemble to stylus PHANTOM Omni User s Guide 5 1 GETTING ACQUAINTED Proper Handling and Positioning of the PHANTOM Omni Positioning the PHANTOM Omni device The correct placement of the device will vary from one user to another You may want to experiment with placement that feels right for you Working with the device should be comfortable and should not put any undo strain on your wrist or forearm Using the included wrist rest may help reduce joint fatigue If you are left handed you may find it easier to work with the mouse placed to the left of the keyboard Remember to take breaks often to stretch your hands wrists and elbows 6 PHANTOM Omni User s Guide 2 Installing the PHANTOM Omni Device This chapter will provide system requirements and describe step by step how to install the PHANTOM Omni haptic device The installation is done in two steps 1 Install the software the device driver th
25. to get familiar with using the PHANTOM Omni device PHANTOM Omni User s Guide 13 2 INSTALLING THE PHANTOM DEVICE Connecting the PHANTOM Omni Device 14 PHANTOM Omni User s Guide 3 Using the PHANTOM Omni Device This chapter will introduce you to working with the PHANTOM Omni haptic device and the physical limits of the device s range of motion It is important to understand these physical limitations so that you do not inadvertently damage the device by forcing it past its designed limits Working in 3D Space We have become so accustomed to using a mouse to move around a computer monitor that we don t think twice as we move our hand around a desk to move the cursor on the computer screen But there was a time not long ago when this seemingly simple task was not second nature some even found it challenging and were often frustrated as they learned If you are new to working in 3D digital space and haptics working with the PHANTOM Omni device may take a little getting used to Understanding where objects are in 3D space may take some practice before you are able to move and manipulate objects with ease and certainty Physical Limits of the Device The PHANTOM Omni device has six degrees of motion All the degrees of motion have physical limits When you reach one of these limits you will feel a sudden stop this is the mechanical stop designed into the device Forcing the device past any of these stops risk
26. xis gt 13 4 Ibs in Z axis gt 5 9 Ibs in X axis 1 26 N mm Y axis 2 31 N mm Z axis 1 02 N mm Inertia apparent mass at tip 0 101 Ibm 459 Footprint 65 8wx 8 d in 168 w x 203 d mm Weight 3 Ibs 15 oz 1 47 kg Operating Temperature 50 to 95 F 10 to 35 C Storage Temperature 40 to 149 F 40 to 65 C Relative Humidity 20 to 80 noncondensing Force Feedback 3 degrees of freedom x y 2 Position Sensing Z digital encoders Pitch roll yaw 5 linearity potentiometers Interface IEEE 1394 FireWire port Input Voltage 100 240 VAC Use supplied power supply only AD 740 1180 Input Frequency 50 60 Hz Input Current 1A Warranty Three months Does not include power supply or cables PHANTOM Omni User s Guide 33
27. ype window make sure that Complete is selected Click Next The next window will read Ready to Install the Program Click Install to begin the installation You will see a status bar Windows XP Users Only A dialog will appear informing you that components of the software have not passed Windows Logo testing This testing is currently underway YOU CAN CONTINUE THE INSTALLATION PROCESS WITHOUT HARMING YOUR SYSTEM Click Continue Anyway each time you see this dialog On the PHANTOM Configuration screen select Omni from the PHANTOM Model pull down menu then click OK The next window will read InstallShield Wizard Completed Select Yes to restart your computer Click Finish At this point the device driver is installed and you are ready to connect your haptic device Connecting the PHANTOM Omni Device In this section you will setup the PHANTOM Omni device and plug in all of the cables Note Exact appearance of your equipment may vary from that shown in the figures Installation instructions for the PHANTOM Omni device follow Restart your computer after installing the PDD if you have not already done so Position the PHANTOM Omni device in your workspace using both hands to grasp the base of the device See Proper Handling and Positioning of the PHANTOM Omni on page 3 for instructions on how to handle the device to reduce the risk of damage Connect the power supply as follows