Home

KUMO Manual

image

Contents

1. Alternate DNS server Validate settings upon exit In the resulting General dialog screen select the Properties button Then on the Networking tab select Internet Protocol Version 4 and click the Properties button below Finally click the Use the following IP address radio button and enter the IP Address and Subnet Mask below e IP Address 192 168 101 2 e Subnet Mask 255 255 255 0 Click the OK button to store the changes KUMO Installation and Operation Manual Setup and Control from a Browser on Windows 7 E Note The previous step is temporary You will later need to restore the original settings on your computer 4 Connect the Windows 7 PC to KUMO s RJ 45 port either direct or through your LAN 5 Point your web browser to 192 168 101 1 6 Once connected to KUMO s web interface reconfigure KUMO s network parameters as desired 7 Restore your computer to its normal network settings using the procedure and IP Addresses you wrote down in Step 3 ED AJA VIDEO SYSTEMS Setup and Control from a Browser on Windows XP Windows XP using UPnP Universal Plug and Play The easiest methods of setting up and controlling a KUMO router from a PC running Windows XP are e Setup and Control from a Browser on Windows XP using UPnP e Setup and Control from a FireFox Browser on Windows XP using Bonjour e Setup and Control from a Browser on Windows XP using a Static IP Address Windows XP PCs
2. eee eee eaaa ae e eee eee eaaa eaaa aaa aa ae eee eee eee 22 Where to Place KUMO eee eee ccc cee cee e eee eee I hh hee 22 Physical ROK SNS aaa gg aa aaa a teg GE GR I GP E NA NEG ER A BR BAT errar 22 Power Reduifrements eee 22 KUMO CONNECHONS 4 cues tenes toon reas asas TRUE SS quU aa NR 23 P S 1 amp P S 2 Power Connectors eaaa RR eaaa aaa aaa hehe 23 RS 422 DBO Connector ee ce cece hh eee e he 23 n5222 o ee A 23 RIAS Ethernet Connector ueste dir ia aa 23 Dana Reset chet Aa a ak seres dls ita riadas ica du Red aaa 23 REF BNC COMMCC O oss 0271529 029 03 2 93 42 artd ad que o n3 Eia esse Abra die ebur En 23 Video Inputs and Outputs ia aan saa BAGA SI BB BENG IHR hs 23 KAJI COME Olio sate ac Ba gag E AA Pa Bani aa Tin BG TETI a aa diario ii Baga EEN Ka Ja aa Ja aga 24 Typical System Control Configurations eee eee eea eea eaaa ea eaaa eee eee 25 KUMO Standalone s sa aas b date aa ando TET BA Ka ABA Ba BAB de KA Ba AN A reia 26 Computer UI with Zeroconf or UPnP oooooooooonnncccccccc cc 27 TCP IP Network Connection 0 cece cc cee cee RR IRR hh hee 28 Default DHCP Configuration ccc ccc cc eee ehh 28 Static IP Configuration hee 28 Default Local IP Address ccc ccc ccc cece cece cence ence RII Hehe n 29 Chapter 3 Web Browser Control Router Web Browser User Interface ccc ccc eee ae ee ehh 31 Navigation Bar Information ccc cece cece ee ee hen
3. iAdvertencia Desenchufe este dispositivo durante tormentas el ctricas o cuando no se lo utilice por largos periodos del tiempo Aviso Desconecte este dispositivo da tomada durante trovoadas ou quando nao utilizado durante longos per odos de tempo Avviso Utilizzare soltanto i collegamenti e gli accessori specificati e o venduti dal produttore quali il treppiedi e l esoscheletro KUMO Compact SDI Routers Before operating your KUMO unit please read the Warning Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any wav such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped Avertissement R f rez vous au personnel de service qualifi pour tout entretien l entretien est exig quand l appareil a t endommag de quelque mani re que ce soit par exemple lorsque le cordon d alimentation ou la prise sont endommag s que du liquide a t vers ou des objets sont tomb s dans l appareil que l appareil a t expos la pluie ou l humidit ne fonctionne pas normalement ou est tomb Warnung Das Gerat sollte nur von qualifizierten Fachkraften gewartet werden Eine Wartung ist f llig wenn das Ger t in irgendeiner Weise besch digt wurde wie bei besch digtem Netzkabel oder Netzstecker falls Fl
4. 4 Proceed to your desired Setup and Control QuickStart method using one of the methods on the following pages EAD AJA VIDEO SYSTEMS The two easiest methods of setting up and controlling a KUMO router system from a Mac are e Setup and Control from a Safari Browser on Mac OSX using Bonjour e Setup and Control from a Browser on Mac OSX using a Static IP Address Safari Browser The Mac OSX Safari browser has Bonjour built in which can be used to auto detect Using Bonjour and connect to a KUMO router To do so 1 Start Safari browser on a Macintosh connected to the KUMO network ensure KUMO to be controlled is powered up and connected via Ethernet directly or via LAN 2 Click on the Bookmark icon menu bar far left and select the Bonjour collection 3 Double click on the KUMO router or control panel in the Bookmarks pane Note The KUMO name will be similar to AJA KUMO1616 555 where 1616 is the model number and 555 is the unit s serial 4 Once you click the KUMO router item Safari will display the KUMO web user interface you can now control the router For additional details read the KUMO user manual on the supplied CD Bonjour 4 Ls http www apple com startpage e Or Bookma rk Ico n jaa 5 Home AJA eo Systems Apple Yahoo Google Maps YouTube Wikipedia News 302 v Popularv Bonjour CO COLLECTIONS 4 History 4 Bookmarks Bar 302 Bookmarks Menu 2 Address Book Bonjour
5. 1 all G 3 aLa Ste 1 Dest2 De Hide au DS BE x Settings KUMO Web Interface I O Configuration Screen Button Settings For any button click outside the naming field to access the Button Settings panel The Settings selection allows you to pick a color from the settings panel to color code the control panel button backgrounds The selected color is set for both the static state color and the High Tally rollover active state Button Settings x Show Hide Lock Unlock Cancel Apply Button Settings Color Panel Lock If you want to lock any of the Destinations from Source changes click on the Lock Unlock box for the desired Destination Note This lock is a universal lock for all KUMO devices controlling the selected Destination It is tallied throughout the network and can be released from other KUMO control devices on the network E AJA VIDEO SYSTEMS Hide You can also hide selected Destinations from display on the local Home control panel by activating the Show Hide box Network Setup The Network screen provides access to standard TCP IP setup fields and allows you to click on the System Name field to change it The MAC address is a fixed machine address composed of manufacturer identification and product serial numbers Click the Update Network Settings button to enter your settings VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input Click IP Address Text to Ed
6. 8 le DECIO la 9 00 ROO RO CRONO 6600606 60006 Guide VIDEO SYSTEMS a 6 6 6 E Version 2 0 Published 11 1 2012 H n a MA tz mm V ION o Installation and Operation 5 im o 10 1007 000 LAM ngan matters PRSI of m n e Because KUMO CP EE AJA VIDEO SYSTEMS Trademarks AJA KONA Ki Pro KUMO and XENA are registered trademarks of AJA Video Inc lo Express lo HD and lo are trademarks of AJA Video Inc Apple the Apple logo AppleShare AppleTalk FireWire iPod iPod Touch Mac and Macintosh are registered trademarks of Apple Computer Inc Final Cut Pro QuickTime and the QuickTime Logo are trademarks of Apple Computer Inc All other trademarks are the property of their respective holders Notice Copyright O 2012 AJA Video Inc All rights reserved All information in this manual is subject to change without notice No part of the document may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying or recording without the express written permission of AJA Inc Contacting Support To contact AJA Video for sales or support use any of the following methods Telephone 800 251 4224 or 530 271 3190 Fax 530 274 9442 Web http www aja com Support Email support aja com Sales Email sales aja com Limited Warranty AJA Video warrants
7. A l mina larga ou o terceiro terminal sao fornecidos para sua seguran a Se a ficha fornecida n o couber na sua tomada consulte um electricista para a substitui o da tomada obsoleta Avviso Non compromettere la sicurezza della spina polarizzata o con messa a terra Una spina polarizzata ha due spinotti di cui uno piu largo Una spina con messa a terra ha due spinotti e un terzo polo per la messa a terra Lo spinotto largo o il terzo polo sono forniti per motivi di sicurezza Se la spina fornita non si inserisce nella presa di corrente contattare un elettricista per la sostituzione della presa obsoleta ES AJA VIDEO SYSTEMS Warning Since the Mains plug is used as the disconnection for the device it must remain readily accessible and operable Avertissement Puisque la prise principale est utilis e pour d brancher l appareil elle doit rester ais ment accessible et fonctionnelle Warnung Da der Netzstecker als Trennvorrichtung dient muss er stets zuganglich und funktionsf hig sein Advertencia Puesto que el enchufe de la red el ctrica se utiliza como dispositivo de desconexi n debe seguir siendo f cilmente accesible y operable Aviso Dado que a ficha principal utilizada como a desconex o para o dispositivo esta deve manter se prontamente acess vel e funcional Avviso Poich il cavo di alimentazione viene usato come dispositivo di sconnessione deve rimane prontamente accessibile e operabile W
8. Physical Requirements 22 Power Consumption 22 Power cord 20 Power Requirements 22 Q Quick start 3 R redundant power supplies 21 8 remove destination lock 41 Reset Buttons 41 RJ45 connector 24 31 Router Delegation Buttons 40 41 router select buttons 26 routers select buttons 42 S safeboot 37 Safeboot Reset 41 safety 21 SDI 1 Shipping Box Contents 20 Source and Destination names 40 Static IP 24 10 Suppress 37 System Name 34 T TCP IP 25 TCP IP setup 34 U unpack 20 update files 35 NE AJA VIDEO SYSTEMS Update Network Settings 34 updates 34 upload 35 UPnP 24 25 27 V video reference signal 37 Voltage 22 W WAN 25 web browser 27 web browsers 24 web server 31 Width 22 Z zeroconf 24 27 ZIP files 35
9. broche pour la mise la terre La broche large ou la troisieme broche sont fournies pour votre s curit Si la prise fournie ne s ins re pas dans votre prise femelle consultez un lectricien pour le remplacement de la prise femelle obsol te Warnung Der Sicherheitszweck des gepolten bzw Schukosteckers ist zu ber cksichtigen Ein gepolter Stecker verf gt ber zwei Pole von denen einer breiter als der andere ist Ein Schukostecker verf gt neben den zwei Polen noch ber einen dritten Pol zur Erdung Der breite Pol bzw der Erdungspol dienen der Sicherheit Wenn der zur Verf gung gestellte Stecker nicht in Ihren Anschluss passt konsultieren Sie einen Elektriker um den veralteten Anschluss zu ersetzen Advertencia No eche por tierra la finalidad del tipo de enchufe polarizado con conexi n a tierra Un enchufe polarizado tiene dos espigas una m s ancha que la otra Un enchufe con conexi n a tierra tiene dos espigas iguales y una tercera espiga que sirve para la conexi n a tierra La expiga ancha o la tercera espiga sirven para su seguridad Si el enchufe suministrado no encaja en el tomacorriente consulte con un electricista para reemplazar el tomacorriente obsoleto Aviso N o anule a finalidade da seguranca da ficha polarizada ou do tipo ligac o terra Uma ficha polarizada tem duas l minas sendo uma mais larga do que a outra Uma ficha do tipo de ligac o a terra tem duas l minas e um terceiro terminal de ligac o a terra
10. earthlink Create a new connection A Disconnected office network eR Change Windows Firewall settings Cal Disable this network device EN Repair this connection mi Rename this connection Cade Wo view status of this LAN or High Speed Internet gt Local Area Connection Status Local Area Connection Properties fx General Support Authentication Advanced connection Connection Change settings of this Status connection Duration Speed Other Places 4 More information I Client for Microsoft Networks File and Printer Sharing for Microsoft Networks D Control Panel Packet Schedule a My Network Places otocol TCP IP L My Documents Activity Description Transmission Control Pratocal Intermet Protocol The default Packets 3 136 Wide area network protocol that provides communication acrozz diverse interconnected networks t Details Local Area Connection LAN or High Speed Internet Limited or no connectivity AAA Realtek RTL8139 810x Family Usable Fast Ethernet MIC C Show icon in notification area when connected Mot me when this connection has limited or no connectivity In the resulting General dialog screen select the Properties button Then on the Local Area Connection Properties dialog select the Internet Protocol item and click the Properties button below it KUMO Installation and Operation Manual Setup and Control from a Browser on Windows XP ED
11. network The control network can be a closed locally attached computer with browser or a TCP IP LAN WAN KUMO devices are compatible with both CAT 5 straight through and cross over Ethernet cables they automatically detect whichever is used A LAN is a shared network that includes other Ethernet devices all attached via a hub or digital switch LANs may be divided into zones separated by software or hardware routers Routers may also be used to connect the LAN to an outside wide area network WAN such as the internet Devices on a LAN have IP addresses which may be fixed and permanent or dynamically assigned by the network DHCP with DNS server Note Once connected and properly configured KUMO can then be controlled by a web browser or one or more KUMO CP control panels KUMO and KUMO CP are equipped with zeroconf Bonjour and support UPnP networking protocols but initially start up as DHCP active devices If you are operating on a DHCP server KUMO will take an assigned IP address and appear on the network Caution When attaching KUMO to a standard Static IP LAN you must configure KUMO components with a new unique IP address You should first talk to your network administrator and find out how it should be connected TCP IP Static IP or DHCP Your IT department will be able to supply the information you need to install KUMO on a LAN Methods for assigning Static IP addressing are discussed later in this Chapter The following
12. CP default IP is set the Source and Destination buttons will flash alternately 3 Configure your Mac computer to talk on the 192 168 XX XX subnet as shown below Important First record existing TCP IP settings so that you can return your computer to normal operation after this procedure Go to your System Preferences gt Network and select Ethernet and Configure Manually AJA VIDEO SYSTEMS Network a Show All a Location enet local 7 17 06 9 23 AM gt e Koy Status Connected Ethernet is currently active and has the IP e la M gt address 0 0 0 0 Es e tid K Configure IPv4 Manually t IP Address 0 0 0 0 Subnet Mask Router DNS Server 10 0 1 1 Search Domains IE Advanced Q Click the lock to prevent further changes Assist me J 1 Revert Apply Mac Enet Setup Screen System Preferences gt Network Input the address information shown below IP Address 192 168 101 2 e Subnet Mask 255 255 255 0 Click Apply 4 Ensure the KUMO device to be controlled is connected to the Mac via Ethernet directly or via LAN 5 Start Safari and enter 192 168 101 1 as a web address This is the KUMO static IP address 6 Once connected to KUMO s web interface reconfigure KUMO s network parameters as desired 7 Restore your computer to its normal network settings using the procedure and IP Addresses you wrote down in Step 3 KUMO Installation and Operation Manual S
13. Internet Protocol TCP IP Properties EEE General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address Subnet mask Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server a cancel Finally click the Use the following IP address radio button and enter the IP Address and Subnet Mask below IP Address 192 168 101 2 e Subnet Mask 255 255 255 0 Click the OK button to store the changes Note The previous step is temporary You will later need to restore the original settings on your computer 4 Connect the Windows XP PC to KUMO s RJ 45 port either direct or through your LAN 5 Point your web browser to 192 168 101 1 Once connected to KUMO s web interface reconfigure KUMO s network parameters as desired 7 Restore your computer to its normal network settings using the procedure and IP Addresses you wrote down in Step 3 EJ NA VIDEO SYSTEMS What s In The Box When you unpack your AJA KUMO SDI router you ll find the following components e KUMO Chassis or KUMO CP option e AC Adapter and AC Power cord e The manual you re reading on CD e Printed QuickStart document plus any late breaking news where app
14. PI RH saa PANA ANE CRECEN _ e Web Browser User Interface Each KUMO CP can control up to 4 KUMO routers Standalone KUMO to KUMO CP and Closed Computer Configurations KUMO Installation and Operation Manual Typical System Control Configurations Computer Ul Using the web browser Ul control method when you connect all the devices and apply with Zeroconf or power KUMO zeroconf or UPnP protocol software will automatically make network UPnP connection with a zeroconf or UPnP compliant and enabled computer Note In this manual zeroconf configuration means using Bonjour for Mac or Windows Using Bonjour you can select each KUMO router or KUMO CP from the Bonjour bookmarks menu to manually configure KUMO options as described in Chapter 3 and KUMO CP options as described in Chapter 4 Hybrid system KUMO s controlled by KUMO CPs and web browsers KUMO CPs KUMO Routers F Multiple KUMO Routers Web Browser User Interface Each KUMO CP can control up to 4 KUMO routers at a time KUMO and KUMO CP with Web Browser Ul Control ES AJA VIDEO SYSTEMS TCP IP Network KUMO also supports traditional TCP IP networking through DHCP or Static IP addressing Connection Important When using KUMO in a DHCP or Static IP addressed network it is best to select and maintain a consistent network scheme If a mixture of DHCP and Static IP addresses are used inconsistent performance can result The most
15. R1 do NOT require the adapter Connect the male end of the adapter to the KUMO unit and lightly tighten it in place using the knurled knobs Connect your serial cable to the other female end of the adapter RJ45 Ethernet The RJ45 Ethernet connector allows you to connect KUMO to an Ethernet 10 100 1000 Connector Ethernet LAN using CAT5 cable as explained in the section that follows Multiple configurations are possible including standalone control a local LAN or a WAN ID and Reset The ID LED lights when you use the web interface to identify the KUMO unit you are controlling The Reset button pinhole below the LED allows a safeboot reset of the unit as explained in Chapter 3 Safeboot Reset on page 37 REF BNC The REF BNC connector is the looping input for genlocking KUMO to your house video connector signals Apply an analog NTSC PAL or Tri level sync signal to this input Also be sure to connect a terminator to the second connector or if you loop from that connector to other equipment be sure to terminate the connection at the other equipment Video Inputs Depending on your KUMO model up to 32 SDI SMPTE 259 292 296 424 video inputs and and Outputs outputs can be connected to the video input and output BNC connectors E 2 KUMO Control TN VIDEO SYSTEMS An RJ45 connector provides a 10 100 1000 Ethernet port for connecting KUMO directly to a computer KUMO CP control panel or Ethernet hub or switch for connecting to a
16. There are no user serviceable parts inside Opening the chassis will void the warranty unless performed by an AJA service center or licensed facility Avertissement Ne pas ouvrir le ch ssis Aucun l ment l int rieur du ch ssis ne peut tre r par par l utilisateur La garantie sera annul e si le ch ssis est ouvert par toute autre personne qu un technicien d un centre de service ou d un tablissement agr AJA Warnung Offnen Sie das Geh use nicht Keine der Ger teteile k nnen vom Benutzer gewartet werden Durch das Offnen des Geh uses wird die Garantie hinf llig es sei denn solche Wartungsarbeiten werden in einem AJA Service Center oder einem lizenzierten Betrieb vorgenommen Advertencia No abra el chasis El interior no contiene piezas reparables por el usuario El abrir el chasis anular la garant a a menos que se lo haga en un centro de servicio AJA o en un local autorizado Advert ncia N o abra o chassi N o h internamente nenhuma peca que permita manutenc o pelo usu rio Abrir o chassi anula a garantia a menos que a abertura seja realizada por uma central de servicos da AJA ou por um local autorizado Avvertenza Non aprire lo chassis All interno non ci sono parti riparabili dall utente l apertura dello chassis invalider la garanzia se non viene effettuata da un centro ufficiale o autorizzato AJA Warning Disconnect the external AC power supply line cord s from the mains power before mov
17. caso agli utenti verr richiesto di adottare tutte le misure necessarie per porre rimedio alle interferenze a proprie spese B 7 AJA VIDEO SYSTEMS Caution To meet safety regulations for leakage current when using redundant power supplies connect the KUMO dual power supplies to separate branch circuits Attention Pour satisfaire aux r glementations sur la s curit concernant le courant de fuite pendant l utilisation d appareils fournisseurs d alimentation redondants branchez les deux appareils fournisseurs d alimentation KUMO des circuits de d rivation distincts Achtung Um die Einhaltung aller Sicherheitsbestimmungen bzgl Ableitstrom beim Einsatz von redundanten Netzteilen sicherzustellen schlie en Sie die zwei KUMO Netzteile bitte an separate Abzweigleitungen an iPrecauci n Para cumplir con las regulaciones de seguridad con el prop sito de evitar p rdidas de corriente cuando se utiliza fuentes de alimentaci n m ltiples conecte las fuentes de alimentaci n dual KUMO a circuitos independientes Atenc o Para atender s regulamentac es de seguranca relativas corrente de fuga ao usar fontes de alimenta o redundantes conecte as fontes de alimenta o duplas KUMO para separar os circuitos derivados Attenzione Per soddisfare i requisiti di sicurezza per la corrente di dispersione usando alimentatori ridondanti collegare i doppi alimentatori KUMO per separare i circuiti derivati Caution KUM
18. in Firefox by going to View gt Sidebar gt BonjourFoxy Or click on the Bonjour logo at the bottom right of your browser window 3 Mozilla Firafox Bookmarks Tools Help k http Tangan ign com view Sidebar Bookmarks Ckrl B Bonjourfoxy Reload Ctrl F gt About C ajAK Zoom Bonjour Page Style logo button Character Encoding Fage Source Ctrl U y Full Screen Fil se ng Firefox Bonjour Sidebar Selection 4 Select your KUMO router from the resulting Bonjour list Mozilla Firefox File Edit View History Bookmark c a 4 A Most Visited Getting Started Bonjour Bonjour sidebar Double click to view KUMO web interface 2 AJA KumoEng1604 21 Firefox BonjourFoxy Sidebar KUMO Installation and Operation Manual Setup and Control from a Browser on Windows XP Windows XP Browser Type in KUMO Static IP Address RS 22 P S1 Y pisa LJ ut 7 es KUMO also offers a factory default static IP address allowing a direct and fail safe way to connect via a PC computer connected to KUMO either directly or via a LAN connection The default static IP address is temporary and is intended only to allow an initial connection Once you ve connected using the static IP you can then enter a desired network configuration using KUMO s Network tab Note The default static address is temporary and will be disabled the next time KUMO restarts Any changes
19. in the Network configuration will be saved upon restart To set the KUMO device to its default static IP address 1 Power up the KUMO router or control panel and wait for it to boot normally 2 Fora router insert a straightened paper clip or similar device into the reset slot on the rear see photo that follows hold for six seconds and then allow KUMO to restart For a KUMO CP press and hold the two blank buttons on the panel for 5 seconds AN JAN IDENTIFY KUMO 1616 Reset Slot Reset Buttons KUMO Reset Slot Location When the KUMO router default IP is set the Identify LED will illuminate and stay on When the KUMO CP default IP is set the Source and Destination buttons will flash alternately 3 Configure your PC computer to talk on the 192 168 XX XX subnet as shown below this example is for a PC connected directly to KUMO Important First record existing TCP IP settings so that you can return your computer to normal operation after this procedure Use Control Panel to access your Local Area Network properties In Windows XP the path is Start gt Control Panel gt Network and Internet Connections gt Network Connections Then under Network Connections locate and click on the Local Area Connection for the PC s Ethernet port ENS AJA VIDEO SYSTEMS Network Connections File Edit wiew Favorites Tool Advanced Help 3 C9 pack O wi JO Search lcs Folders EE Dial up Network Tasks
20. normal computer IP address information should be recorded and reset when the procedure is done To enable the factory default local IP address follow the procedure described in Chapter 1 Windows 7 Browser Type in KUMO Static IP Address on page 11 When the KUMO Ul is refreshed in the browser go to the Network tab and you will see the new IP address setting This is also useful for an application in which you directly connect a laptop or computer to KUMO and want to get networking quickly or if you need to reset due to errors in software updating EJ ANA DEO Chapter 3 KUMO Router Web Browser Interface VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input AJA KUMO1604 505 SOURCE 1 2 3 4 9 6 7 8 9 10 11 12 13 14 15 16 Source 1 Source2 Source3 Source4 Source5 Source6 Source Source8 Source 9 Source 10 Source 11 Source 12 Source 13 Source 14 Source 15 Source 16 DESTINATION 1 2 Dest 1 Router Web Browser User Interface An optimized web server inside the KUMO allows you to remotely monitor and adjust parameter settings via a network attached computer running a web browser The network can be a closed local area network a straight computer to KUMO Ethernet cable or even exposed through a firewall to a broadband WAN not generally recommended since anyone on the internet can then access the KUMO The LAN connection on the KUMO uses a standard RJ45 connector but internally it s in
21. number of KUMO routers and up to 16 KUMO CP control panels Quick start configurations are discussed in this chapter for complete network control and IP address information see Chapter 2 Getting Started on page 21 KUMO Installation and Operation Manual KUMO Quick Start E KUMO Quick Start This Quick Start Guide provides a basic overview of KUMO configuration It is not meant as a substitute for the detailed information found throughout the rest of this manual but as a quick way to get your KUMO set up quickly and operating We strongly recommend that you read the full KUMO Manual to get the most out of your system KUMO Setup and KUMO SDI routers are easy to set up and use Regardless of system configuration Control all KUMOs can be controlled via a web browser This can be via a simple direct connection between a KUMO router and a PC or Mac computer or by a LAN connection using an Ethernet hub or switch to interconnect one or many KUMOs for larger system configurations The KUMO CP remote control panel option allows you to control a KUMO router without any computer interface at all For details see KUMO Remote Control Panel on page 39 Direct Connection In a direct connection you simply connect the control computer Mac PC or a KUMO CP control panel to a KUMO router using an Ethernet cable cat 5 between the RJ45 connectors on both devices KUMO CP KUMO Router Direct Cat 5 ethernet cable connection K
22. panel C IDENTIFY KUMO 1604 Chapter 4 KUMO Remote Control Panel KUMO Remote Control Panel The KUMO CP Control Panel is a destination oriented panel allowing selection of 16 sources to 16 destinations on each of up to four KUMO routers The control panel will connect to a single KUMO router straight Cat 5 connection automatically without computer browser interface For connection to up to four routers at a time use the KUMO browser interface to assign the router select buttons to any four KUMO routers on your network Direct Connect KUMO Control KUMO Router KUMO CP Cat 5 Ethernet Cabling Up to 4 KUMOs per Control Panel Web Browser User Interface Direct Control Panel KUMO Network With Browser Interface ES AJA VIDEO SYSTEMS Panel Function Buttons In this multi router network configuration with Ethernet connection between control panels and routers the Router Delegation Buttons shown below are assigned to up to four active routers using the control panel web interface for details see Home Page on page 42 Connectors and Indicator KUMO CP provides inputs for two power supplies one included redundant supply optional An RJ 45 connector provides 10 100 1000 Ethernet connection to the internal Linux OS web server Power Supply Identify LED Ethernet Connectors wena aja CO 10410011000 LAN KUMO CP KUMO CP Connectors and Indicator Button Key C
23. ssigkeiten oder Objekte in das Ger t gelangen das Ger t Regen oder Feuchtigkeit ausgesetzt wurde nicht ordnungsgem funktioniert oder fallen gelassen wurde Advertencia Consulte al personal calificado por cuestiones de reparaci n El servicio de reparaci n se requiere cuando el dispositivo ha recibido cualquier tipo de da o por ejemplo cable o espigas da adas se ha derramado l quido o se han ca do objetos dentro del dispositivo el dispositivo ha sido expuesto a la lluvia o humedad o no funciona de modo normal o se ha ca do Aviso Remeta todos os servicos de manutenc o para o pessoal de assist ncia qualificado A prestacao de servicos de manutenc o exigida quando o dispositivo foi danificado mediante qualquer forma como um cabo de alimentac o ou ficha que se encontra danificado a quando foi derramado l quido ou ca ram objectos sobre o dispositivo quando o dispositivo foi exposto a chuva ou a humidade quando n o funciona normalmente ou quando foi deixado cair Avviso Fare riferimento al personale qualificato per tutti gli interventi di assistenza l assistenza e necessaria quando il dispositivo stato danneggiato in qualche modo ad esempio se il cavo di alimentazione o la spina sono danneggiati stato rovesciato del liquido stato rovesciato o qualche oggetto caduto nel dispositivo il dispositivo stato esposto a pioggia o umidit non funziona correttamente o caduto Caution This device is
24. the Home page The panels router select button will tally appropriately KUMO Installation and Operation Manual KUMO Remote Control Panel ES Configuration Page Using the Configuration page you can e Adjust the Display Intensity slider select one of four button illumination levels e Reset Auto Configure resets the Auto Configure function to automatically set up one control panel to one router This function re boots the panel to trigger the configuration Upon reboot if any other router is found on the network it will not pair to the panel e Reset to Factory Defaults resets all user settings to factory defaults VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY JSCP40 2 Display Intensity 2 Reset Auto Configure Reset To Factory Defaults KUMO CP Browser Configuration Page Identify Button Click on the Identify button to find the physical location of currently controlled panel The web browser button will alternate between blue and gray background color in Identify mode On the connected control panel the Source and Destination button rows will flash alternately Also the Identify LED on the back of the panel will flash Click a second time to resume normal operation VIDEO SYSTEM HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY KUMO CP Identify Button EJ ANIA DEO Appendix A Specifications KUMO SDI Router Specifications Formats 3 0 Gbps
25. 03 du Canada EZ AJA European Union and European Free Trade Association EFTA Regulatory Compliance Declaration of Conformity This equipment may be operated in the countries that comprise the member countries of the European Union and the European Free Trade Association These countries listed in the following paragraph are referred to as The European Community throughout this document AUSTRIA BELGIUM BULGARIA CYPRUS CZECH REPUBLIC DENMARK ESTONIA FINLAND FRANCE GERMANY GREECE HUNGARY IRELAND ITALY LATVIA LITHUANIA LUXEMBOURG MALTA NETHERLANDS POLAND PORTUGAL ROMANIA SLOVAKIA SLOVENIA SPAIN SWEDEN UNITED KINGDOM ICELAND LICHTENSTEIN NORWAY SWITZERLAND Marking by this symbol indicates compliance with the Essential Requirements of the EMC Directive of the European Union 2004 108 EC This equipment meets the following conformance standards Safety CB IEC 60065 2001 A1 2005 NRTL UL 60065 2003 R11 06 CSA C22 2 NO 60065 2003 A1 06 GS EN 60065 2002 A1 Additional licenses issued for specific countries available on request Emissions EN 55103 1 1996 EN61000 3 2 2006 EN61000 3 3 1995 A1 2001 A2 2005 Immunity EN 55103 2 1996 EN61000 4 2 1995 A1 1999 A2 2001 EN61000 4 3 2006 EN61000 4 4 2004 EN 61000 4 5 2005 EN 61000 4 6 2007 EN61000 4 11 2004 The product is also licensed for additional country specific standards as required for the International Marketplac
26. 1 5 Gbps 270 Mbps ASI Auto Select Video Inputs Outputs Standards SDI SMPTE 259 292 296 and 424 BNC Cable Equalization 270 Mb 400 meters BNC inputs 1694 coax 1 5 Gb 200 meters 3 Gb 140 meters Input Output Return Loss BNC gt 15dB to 270Mb gt 10db 1 5Gb to 3Gb Reference Input Analog input passive looping BNCs Format NTSC PAL Tri level sync Control 10 100 1000 Ethernet RJ 45 internal Linux OS web server RS 422 Serial DB9 female Environment Operating Temperature 0 to 40 Degrees C Relative Humidity O to 90 non condensing Power 12 VDC nominal 9 18 VDC range optional redundant power KUMO 1604 7 5 Watts 0 8A 0 8A at 12VDC KUMO 1616 20 Watts 1 8A 1 8A at 12VDC KUMO 3232 26 4 Watts 2 2A at 12VDC Size Depth 1 RU 1 5 38 1 mm 2 RU 1 543 39 2 mm Height 1 RU 1 72 43 7 mm 2 RU 3 47 88 14 mm Width 1 RU and 2 RU 19 483 mm Weight KUMO 1604 1 2 Ib 55 kg KUMO 1616 1 4 Ib 64 kg KUMO 3232 4 58 Ibs 2 1 kg SDI Signal Switch Note KUMO routers switch SDI signals in a manner compliant with SMPTE RP168 2009 Because KUMO routers or any SDI router switch the SDI stream without de serializing the switch point can cause a temporary anomaly in the SDI stream This can cause downstream equipment depending on the characteristics of the SDI receiver to react to the switch for example a monitor glitch or roll This effect occures regardless of the relative timing of
27. 3 47 8 814 cm Depth 1 543 3 92 cm Width 19 48 3 cm Power e Input Voltage 110 220VAC 50 60Hz to 12 VDC brick converter supply Requirements fully redundant with optional second brick supply AJA recommends AJA p n 103147 00 e Power Consumption KUMO 1604 9 Watts KUMO 1616 20 Watts KUMO 3232 26 4 Watts Caution KUMO is designed to take advantage of its chassis to aid in cooling It is common and expected for the densely populated 1616 chassis to have a warm front panel in normal active operating conditions Warning Do not open the chassis There are no user serviceable parts inside Opening the chassis will void the warranty unless performed by an AJA service center or licensed facility Remove the brick power supply AC line cord s from mains power when moving the unit Redundant 12 VDC RJ45 Ethernet REF BNC In Power Supplies 10 100 1000 Ext Ref Video SDI Video Inputs 1 32 P S 1 amp P 5 2 LAN Connector Looping top two rows ESAE pee Sod 2 P a Q A m zu IDENTIFY KUMO 3232 ho En g cE a O oa y gt C NECI a OUTPUTS t t Q RS 422 Serial Identify LED amp SDI Video Outputs 1 32 DB9 Female Reset Slot bottom two rows Connector below LED KUMO Connections 3232 shown other models similar KUMO Installation and Operation Manual KUMO Connections ES KUMO Connections The rear panel illustration po
28. A product based on the standard of the VCCI Council VCCI V 3 2008 04 If this equipment is used in a domestic environment radio interference may occur in which case the user may be required to take corrective actions EZ AJA VIDEO SYSTEMS Translated caution statements warning conventions and warning messages The following caution statements warning conventions and warning messages apply to this product and manual Warning Symbol Caution Symbol Before operating your KUMO unit please read the instructions in this document Warning Read and follow all warning notices and instructions marked on the product or included in the documentation Avertissement Lisez et conformez vous a tous les avis et instructions d avertissement indiqu s sur le produit ou dans la documentation Warnung Lesen und befolgen Sie die Warnhinweise und Anweisungen die auf dem Produkt angebracht oder in der Dokumentation enthalten sind Advertencia Lea y siga todas las instrucciones y advertencias marcadas en el producto o incluidas en la documentaci n Aviso Leia e siga todos os avisos e instruc es assinalados no produto ou inclu dos na documentac o Avviso Leggere e seguire tutti gli avvisi e le istruzioni presenti sul prodotto o inclusi nella documentazione Warning Do not use this device near water and clean only with a dry cloth Avertissement N utilisez pas cet appareil pr s de l eau et nettoyez le seulemen
29. Bonjour sidebar in Firefox by going to View gt Sidebar gt BonjourFoxy You can also launch the sidebar by clicking on the Bonjour logo at the bottom right of your browser window Reload BonjourFoxy Zoom j mi iin ki Page Style lab Pant Character Encoding Page Source Ctrl U Bo nj our Full Screen Fil logo button es Firefox Bonjour Sidebar Selection 4 Select your KUMO router or control panel from the resulting Bonjour list Ele Edit View History Bookmarks Tools MH ey d http s Most Visited ie Getting Started EN Latest BonjourFoxy NH Pr Bonjour sidebar p al ial Websites AJA KumoEng1604 21 local ug Double click to view KUMO jah Wiki web interface id Printers Firefox BonjourFoxy Sidebar KUMO Installation and Operation Manual Setup and Control from a Browser on Windows 7 EB Windows 7 Browser Type in KUMO Static IP Address KUMO also offers a factory default static IP address allowing a direct and fail safe way to connect via a PC computer connected to KUMO either directly or via a LAN connection The default static IP address is temporary and is intended only to allow an initial connection Once you ve connected using the static IP you can then enter a desired network configuration using KUMO s Network tab Note The default static address is temporary and will be disabled the next time KUMO restarts Any changes in the Network configurati
30. Collection All RSS Feeds AJA KUMOCPTechw Bookmark A About Bonjour QF AJA KUMOCPTechw C9 AJA KUMOEng1604 21 C9 AJA KUMOEng1604 27 KUMO CP KUMO Routers Safari Bonjour Bookmarks KUMO Installation and Operation Manual Setup and Control from a Browser on Mac OSX Safari Browser Type in KUMO Static IP Address KUMO also offers a factory default static IP address allowing a direct and fail safe way to connect via a Mac computer connected to KUMO either directly or via a LAN connection The default static IP address is temporary and is intended only to allow an initial connection Once you ve connected using the static IP you can then enter a desired network configuration using KUMO s Network tab Note The default static address is temporary and will be disabled the next time KUMO restarts Any changes in the Network configuration will be saved upon restart To set KUMO to its default static IP address 1 Power up KUMO and wait for it to boot normally 2 Fora router insert a straightened paper clip or similar device into the reset slot on the rear see photo that follows hold for six seconds and then allow KUMO to restart For a KUMO CP press and hold the two blank buttons on the panel for 5 seconds AN JAN waw aa com IDENTIFY KUMO 1616 Reset Slot Reset Buttons KUMO Reset Slot Location When the KUMO router default IP is set the Identify LED will illuminate and stay on When the KUMO
31. Cue CS4 32 bit 4 Look at the resulting device list under Other Devices double click a KUMO s name to launch your Window 7 PC s default browser The browser will display the KUMO web interface Use it to control KUMO Organze Network and Sharing Center Add a printer Add a wireless device E Favorites Name Category l Workgroup Network location 5 Recently Changed di Computer 2 di Public JI THADSVISTA amp 4DEM Computer WORKGROUP et Wi Desktop iN TOMMACGO Computer WORKGROUP baa asked once Jp Downloads 5 Recent Places 4 Media Devices 1 e THADSVIS T ABA DEM demo Media Devices Metwork 5 Libraries 4 Other Devices 1 a De t AS L AJA KUMO1616 555 ih ar Devices LET En Ed mebagii a Music Pictures H Videos Double click the KUMO name to launch your default web browser Windows Network Screen ENS AJA VIDEO SYSTEMS Windows 7 FireFox Using Bonjour with Windows 7 and the FireFox browser requires installing the Using Bonjour Bonjour for Windows software plus a FireFox plug in Bonjour for Windows can be downloaded at http developer apple com networking bonjour download The FireFox browser plug in BonjourFoxy can be download from www Bonjourfoxy net To Connect after installing both Bonjour and the plug in 1 Ensure the KUMO device to be controlled is powered up and connected via Ethernet to the Windows 7 PC directly or via LAN 2 Launch the FireFox web browser 3 Access the
32. EP KAE P AE ETE A1 KUMO EP Specifications secre oru ides AAA A AAA A2 Appendix B Safety and Compliance Federal Communications Commission FCC Compliance Notices ooooooooo B1 Class A Interference StateMent ooocoooccccccccccrr rr B1 a Ol OT A PP A a a Bn eee B 1 Canadian CES Statements saa pie tho a NA a is BP D bs SI Ped E bes B 1 European Union and European Free Trade Association EFTA Regulatory COMP DAA need ees B2 Declaration Of Contormmlty usq e rp UE eR e Dedi ag Ps E a ag M ng GE aa ah B2 Korea KCC Compliance Statement sarasa aaa ccc a cee eee cece Bg a Bi a a ap aa ag a aaa Aa B3 Taiwan Compliance Statement 0 ccc ccc cece rro B3 Japanese Compliance Statement 2 0 ccc cc ccc cece eee cece eee Ka Ba aa a KA A a B3 Translated caution statements warning conventions and warning messages B4 Before operating your KUMO unit please read the instructions in this document B4 Index vii AJA VIDEO SYSTEMS Chapter 1 Introduction Rear Panel 1616 3 4 5 6 T B 8 10 11 12 13 14 15 18 Rear Panel 1604 l VANO OiOi OO 2 OOO OOOO LD Typical Front Panel Control Panel Option o Q Q y O 0060060 CHC RC o o 0 06006 Rear Panel 3232 0 EA AA WED am DIS mm WEAS A as VAY CC cuc 00600 06066 606009 a a CO OO 606060606 6 o o 6 Overview KUMO compact SDI routers are small and c
33. K button and then click Next in the Windows Components Wizard You may need to provide your Windows XP installation CD 5 Go to Start gt My Network Places again and look for the KUMO icon as shown previously UPnP devices on your local network will be displayed there including KUMO Whenever a KUMO is connected a notifying icon will appear briefly in the System Tray When you see the icon go to My Network Places to find the KUMO icon and double click it to launch KUMO s web interface for control and setup A Microsoft Internet Explorer File Edit View Favorites Tools Help Back o i2 A pO Seat Address lhtpubwmeqondecom 00000 b HINT e KE Bonjour Bonjour sidebar y About Bonjour AJA KumoEng1604 2 Double click to view KUMO web interface ES AJA Windows XP FireFox Using Bonjour VIDEO SYSTEMS Using Bonjour with Windows XP and the FireFox browser requires installing the Bonjour for Windows software plus a FireFox plug in called BonjourFoxy Bonjour for Windows can be downloaded at http developer apple com networking bonjour download The FireFox browser plug in BonjourFoxy can be download from www Bonjourfoxy net To Connect after installing both Bonjour and the plug in 1 Ensure KUMO to be controlled is powered up and connected via Ethernet to the Windows XP PC directly or via LAN 2 Launch the FireFox web browser 3 Access the Bonjour sidebar
34. O is designed to take advantage of its chassis to aid in cooling It is common and expected for the densely populated 1616 chassis to have a warm front panel in normal active operating conditions Attention KUMO est concu pour tirer parti de son chassis pour le refroidissement Il est normal et attendu que le panneau frontal du tr s compact ch ssis 1616 demeure chaud dans des conditions normales de fonctionnement Achtung Das Design von KUMO nutzt das Geh use zur K hlung Es ist normal und entspricht den Erwartungen dass die Vorderseite des dicht best ckten 1616 Geh uses bei normalen aktiven Betriebsbedingungen warm ist Precauci n KUMO est dise ado para aprovechar el chasis para asistir en el proceso de enfriamiento Es com n y est previsto que el chasis 1616 densamente surtido de componentes tenga el panel frontal caliente en condiciones normales y activas de funcionamiento Atenc o O KUMO foi projetado para aproveitar seu chassi para auxiliar no resfriamento normal e esperado que o chassi 1616 densamente preenchido apresente um painel frontal aquecido em condi es de opera o normais e ativas Attenzione KUMO sfrutta lo chassis per migliorare il raffreddamento normale per lo chassis 1616 data la concentrazione di cavi che il panello anteriore si riscaldi durante la normale attivit KUMO Compact SDI Routers Before operating your KUMO unit please read the EE Warning Do not open the chassis
35. RNING You are uploading new firmware to the KUMO After the new firmware is uploaded it will be verified and the version number of the firmware will be displayed You will then be asked if the firmware should be commited to internal flash memory After the firmware has been committed to flash you will be asked to confirm a reboot of the KUMO Note Your settings and configuration will remain as they are now Upon confirming a reboot you will be redirected to the front page of the web Ul and when the new software is up and running this web UI will start working again The progress meter on this web page should keep you informed of the progress Note Current and past releases of KUMO software are available on the World Wide Web from AJAYs website To get the software point your browser to KUMO Update Page KUMO Web Interface Firmware Upload Screen KUMO Installation and Operation Manual Router Web Browser User Interface ES Unpack the Software Download the latest version of KUMO firmware and use the Firmware screen to upload it to your KUMO router KUMO software update files are ZIP files which you can open with a number of standard and third party uncompressor applications The software image that you ll install on KUMO is a file with a name similar to kumo_ver_1 1 1 1270485530 bin Note Depending on your PC or Mac operating system settings the bin extension may not be visible to you in a file directory Uploa
36. UMO Router Web Browser User Interface KUMO Direct Connection to Mac PC Web Browser or KUMO CP to KUMO The KUMO CP Auto Configure assigns Router Select Button 1 to the attached router E AJA VIDEO SYSTEMS LAN Connection Using a Hub or Switch Ina LAN connection connect one or more KUMO routers to your LAN or closed network using Cat 5 Ethernet cable and an Ethernet hub or switch then power up the equipment LAN only system use TCP IP to configure routers and devices 1 Use Bonjour or configure KUMOs TCP IP settings 2 Control KUMOs from a web browser aaa aaa ae al Control Unlimited KUMO Routers via TCP IP Web Browser User Interface KUMO LAN with Web Browser Ul KUMO Installation and Operation Manual KUMO Quick Start E QuickStart Setup Regardless of Direct Connection or LAN Connection KUMOs are controlled over a and Control network by connecting to KUMOS internal webserver with a standard web browser on Methods a Mac or PC To do this you first need to establish a network connection between the computer and the KUMO to be controlled There are various methods supported for doing this depending on the operating system and or web browser being used Choose one of the following quick start procedures that best fits your environment each procedure is presented in step by step form later on these pages Mac OSX e Setup and Control from a Safari Browser on Mac OSX us
37. Y TO IMPLEMENT REDUNDANT CAPTURE AND BACKUP SYSTEMS AS APPROPRIATE Limitation of UNDER NO CIRCUMSTANCES SHALL AJA VIDEO BE LIABLE IN ANY WAY FOR ANY LOST Liability CORRUPTED OR DESTROYED DATA FOOTAGE OR WORK OR FOR ANY OTHER INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR FOR ANY THIRD PARTY CLAIM IN CONNECTION WITH THE PRODUCT WHETHER RESULTING FROM DEFECTS IN THE PRODUCT SOFTWARE OR HARDWARE FAILURE OR ANY OTHER CAUSE WHATSOEVER EVEN IF AJA VIDEO HAS BEEN ADVISED OF THE POSSIBLITY OF SUCH DAMAGES AJA VIDEO s LIABILITY IN CONNECTION WITH THIS PRODUCT SHALL UNDER NO CIRCUMSTANCES EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT AJA VIDEO SYSTEMS KUMO Table of Contents Front Matter Trademarks senos sr ar ro a PATI TERRE TERTIA TEES M ii poo PETT a A ii CONLACHNG SUDDO e E aora epica Fd dE qM Md re IM DE EP ii aree WAL E YE ah E eem ta d usate ep RERUM Te d viae Vd de a NR E li Biraneewuodi oin Pi ga RA iii Chapter 1 Introduction A o TA AA BA ak Ra KT OOA Ba Aa a IN TAA ae aa aa nag a aaa aa aa a 1 KUMOFeatUrOS P 2 KUMO Control and Monitoring cece cece eee e aee I ns 2 Network Configuration Overview ccc ccc ccc ccc eee ehh es 2 RUMO QUICK STE errar nero viaria MEE 3 KUMO Setup and Control oooooococoonccccccnnn rr 3 Deco GOMMECU OM aie E 3 LAN Connection Using a Hub o
38. a Class A product Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense Attention Le p riph rique est un produit de Classe A Le fonctionnement de cet quipement dans une zone r sidentielle risque de causer des interf rences nuisibles auquel cas l utilisateur devra y rem dier ses propres frais Achtung Dies ist ein Ger t der Klasse A Bei Einsatz des Ger ts in Wohngebieten kann es St rungen des Radio und Fernsehempfangs verursachen In diesem Fall muss der Benutzer alle notwendigen Ma nahmen ergreifen die m glicherweise n tig sind um die St rungen auf eigene Rechnung zu beheben iPrecauci n Este es un producto clase A El uso de este equipo en reas residenciales puede causar interferencias nocivas en cuyo caso se requerir que los usuarios tomen cualquier medida necesaria para corregir la interferencia por cuenta propia Cuidado Este dispositivo um produto Classe A Operar este equipamento em uma rea residencial provavelmente causar interfer ncia prejudicial neste caso espera se que os usu rios tomem as medidas necess rias para corrigir a interfer ncia por sua pr pria conta Attenzione Questo dispositivo un prodotto di Classe A II funzionamento di questo apparecchio in aree residenziali potrebbe causare interferenze dannose nel cui
39. a Ethernet e 1RU form factor for 16x16 2 RU for 32x32 e Redundant Power optional isolated power inputs KUMO Control and Monitoring The KUMO router user interface provides powerful remote setup control and monitoring with e Zero configuration Bonjour Protocol and support for UPnP networking protocols e Remote web browser control interface via Ethernet e Optional push button remote control panel for control of up to 4 routers assignable through the web interface e GVG Native Protocol built in to allow serial or LAN interconnection one RS 422 or up to ten Ethernet and interoperability with other equipment For details about GVG Native Protocol please refer to http www grassvalley jp pdf RoutingProductsProtocolManual_2 paf Network Configuration Overview Networks can be e Closed local area networks e A straight computer to KUMO cable e Astraight optional control panel to KUMO cable without computer interface e Or for the greatest flexibility exposed through a firewall to a broadband WAN KUMO s internal HTTP networking software supports three levels of network control described on the following pages e Closed KUMO network uses Bonjour e Auto Configured LAN employs a Bonjour or UPnP enabled computer browser to automatically connect devices and allows KUMO web browser User Interface UI e Standard TCP IP network employs DHCP or Static IP addressing and allows the KUMO web based Ul and an unlimited
40. aps Each control panel button has a removable lens cap that allows you to customize Source and Destination names AJA has provided a template for printing custom lens chips we suggest using 29 lb vellum for button designations The template is available on your software CD and at http www aja com support kumo lens_chip zip Each KUMO Control Panel provides e Panel Lock prevents Source or Destination changes from this panel e Destination Lock prevents any Source change for a Destination e Router Delegation Buttons RTR 1 RTR 4 enable immediate control of the KUMO assigned to the button KUMO CP Function Buttons Panel Lock When you press the Panel Lock button it lights red and all panel functions for this panel are disabled All other KUMO devices on the network will function normally KUMO Installation and Operation Manual KUMO Remote Control Panel E Destination Lock Press the Destination Dest Lock button to prevent any changes to the KUMO destination you are currently controlling Dest button high tallied The lock can be removed from any other KUMO CP or browser interface on the network The DEST and DEST LOCK buttons turn red on all panels that are assigned to the KUMO you are controlling You can select other destinations and apply the Dest Lock function to each All locks will tally red To remove the lock select the destination and press Dest Lock again Note Locked destinations are reported o
41. arning Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the device Avertissement Prot gez le cordon d alimentation pour que l on ne marche pas dessus ou qu on le pince en particulier au niveau des prises m les des r ceptacles de convenance et l endroit o il sort de l appareil Warnung Es muss verhindert werden auf das Netzanschlusskabel zu treten oder dieses zu knicken besonders an den Steckern den Steckerbuchsen und an dem Punkt an dem das Kabel aus dem Ger t heraustritt Advertencia Puesto que el enchufe de la red el ctrica se utiliza como dispositivo de desconexi n debe seguir siendo f cilmente accesible y operable Aviso Proteja o cabo de alimentac o de ser pisado ou de ser comprimido particularmente nas fichas em tomadas de parede de conveni ncia e no ponto de onde sai do dispositivo Avviso Proteggere il cavo di alimentazione in modo che nessuno ci cammini sopra e che non venga schiacciato soprattutto in corrispondenza delle spine e del punto in cui esce dal dispositivo Warning Unplug this device during lightning storms or when unused for long periods of time Avertissement D branchez cet appareil pendant les orages avec clairsou s il est inutilis pendant de longues p riodes Warnung Das Ger t ist bei Gewitterst rmen oder wenn es ber lange Zeitr ume ungenutzt bleibt vom Netz zu trennen
42. button on the unit and when the Identify LED lights the KUMO will MAC Address 00 0C 17 87 00 1B have a temporary IP address of 192 168 101 1 and a netmask of 255 255 255 0 Update Network Settings Update Network Settings allowing you to connect to it there and fix any network configuration errors KUMO User Interface Network Tab There are two ways to access the KUMO web browser UI to set up Static IP 1 Connect directly to the KUMO device in a closed connection using Zeroconf or UPnP protocol to locate KUMO via Bonjour or Windows Network also called My Network Places KUMO will come up with a name similar to AJA Kumo1616 505 where 1616 is the KUMO model and 505 represents it s serial number in the Bonjour menu or Windows Network Note To use UPnP your computer must have the UPnP Service enabled Refer to your Windows documentation to enable UPnP technology and multicast network traffic a simplified how to is given in the QuickStart topic in Chapter 1 Click the KUMO name to open the web browser UI and access the Network page Connect directly to the KUMO or KUMO CP and use the KUMO default local IP address that is set at the factory 192 168 101 1 to point your browser to the web browser UI and the Network page x KUMO Installation and Operation Manual Typical System Control Configurations ES Default Local IP Address Important This procedure should be done by those experienced with TCP IP network setup All
43. dd or Remove Programs 2 In the Add or Remove Programs dialog box click Add Remove Windows Components KUMO Installation and Operation Manual Setup and Control from a Browser on Windows XP E F Control Panel File 1 Add or Remove Programs Currently installed programms C Show updates Change or Remove Programs Click here For support information j To remove this pr TM c P 2 Windows Components Wizard L g F Add Mew Networking Services Programs To add or remove a component click the check box 4 shaded box means that only part c of the component will be installed To see what s included in a component click Details nddiRemave subcomponents of Networking Services Windows Internet Gateway Device Discovery and Control Client 0 0 MB Components Peer to Peer a RIP Listener OA si Y c alm i Set Program dall UP HP User Interface Check this Box Access and Defaults Description Allows unu to find and control Internet connection sharing hardware and software that uses UFPnPIT M Total disk space required 54 8 MB Space available on disk 434 78 0 MB Details 3 In the Windows Components Wizard click Networking Services and then click the Details button below You ll see a Networking Services dialog locate the UPnP User Interface checkbox and click in it to check the box and enable UPnP service 4 Click the O
44. ding and Installing Firmware to KUMO Uploading and installing the software update only requires a PC or Mac that can see the KUMO via its browser Follow this procedure to install the software 1 Point your browser at the downloaded KUMO upgrade file on your computer by clicking on the Browse button on the Firmware screen HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input AJA KUMO1604 505 Uploaded Firmware Version 1 1 1 25 Would you like to commit the uploaded firmware to flash now Cancel Commit Uploaded Firmware 3 2 When you have selected a valid KUMO image file click the Upload button in the web browser The file you select will upload to the KUMO and be tested for validity Incomplete corrupted or non KUMO software files are rejected HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input AJA KUMO1604 505 Overall Progress Preparing Flash For Writing Wait for the procedure to complete it will take only a few minutes E AJA VIDEO SYSTEMS 3 When done click the Restart button to reset your KUMO and refresh the web browser and KUMO UI HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input AJA KUMO1604 505 Writing Firmware Completed Successfully Restart KUMO With New Firmware Once these steps are complete the KUMO will be running the software you just uploaded until the next time you upgrade i
45. e Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten in welchen Fallen der Benutzer f r entsprechende Gegenma nahmen verantwortlich ist Attention Ceci est un produit de Classe A Dans un environnement domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilisateur de prendre les mesures sp cifiques appropri es KUMO Compact SDI Routers Korea KCC Compliance Statement EZ Korea KCC Compliance Statement 1 Class A ITE TS AT OE AAA s JE Eeee ol aa LE APB SHE AN 1 Class A device Class A Please note that this equipment has Broadcasting and obtained EMC registration for business Communication use Class A and it is intended to use in Equipment for Business Use other than home area Taiwan Compliance Statement mH PA gt ERE AAAS UA AST SA T3 gt HEBE CAS AREA AR This is a Class A product based on the standard of the Bureau of Standards Metrology and Inspection BSMI CNS 13438 Class A Japanese Compliance Statement 1 Class A ITE TO E 72 ZA RTE C d OREA RIDE CORT SC BS AECI CENIDE CORA RADAR I OLIOBREN ATE haJ VCC I A This is a Class
46. etup and Control from a Browser on Windows 7 ED Setup and Control from a Browser on Windows 7 The easiest methods of setting up a controlling a KUMO device from a PC running Windows 7 are e Setup and Control from a Browser on Windows 7 using UPnP e Setup and Control from a FireFox Browser on Windows 7 using Bonjour e Setup and Control from a Browser on Windows 7 using a Static IP Address Windows 7 Using If your Windows 7 PC supports UPnP protocols most do and UPnP service is enabled UPnP Universal refer to your MicroSoft Windows documentation you can control KUMO routers by Plug and Play simply selecting one from a device list 1 Ensure KUMO to be controlled is powered up and connected via Ethernet directly or via LAN 2 Use your Windows 7 Control Panel to go to Network and Internet 3 Select View Network computers and devices GOU Control Panel amp Network and Internet he Search Control Panel D Control Panel Home WA ki Network and Sharing Center S PE View network status and tasks Connectto a network View network computers and devices System and Security Add a wireless device to the network i Network and Internet Click This Hardware and Sound ad aaa aha i Choose homegroup and sharing options i Programs User Accounts and Farnily m Internet Options Safety Change your homepage Manage browser add ons Delete browsing history and cookies Pre and lal Adobe Version
47. formac es necess rias para instalar o KUMO em uma LAN M todos para atribuir enderecos IP est tico s o abordados no manual de Instalac o e Operac o do KUMO Attenzione Quando si collega KUMO a un IP LAN statico standard occorre configurare i componenti KUMO con un nuovo indirizzo IP univoco Per prima cosa occorre parlare con l amministratore di rete e scoprire come effettuare la connessione IP statico TCP IP o DHCP Il reparto IT potr fornire le informazioni necessarie per installare KUMO su una LAN metodi di assegnazione dell indirizzo IP statico sono illustrati nel manuale KUMO Installazione e funzionamento Index A assign routers 42 Auto Configure 43 B Bonjour 24 button colors 33 Button Key Caps 40 C CAT 5 ethernet cable 31 color code buttons 33 control panel identify 43 control panel resets 43 custom lens chips 40 D deactivate alarms 37 default IP address 25 41 Depth 22 Destination Lock 40 DHCP 24 Dimensions 22 display intensity 42 Download 35 E error condition 37 E firmware version 34 G glitch or roll 1 H Height 22 Identify button 38 43 Identify LEDs 38 Installation 21 installing software 35 IP address reset 41 IP addresses 24 K KUMO CP 26 L LAN 24 lens chips 40 M MAC address 34 Manual 20 mounting methods 22 multi router network 40 N Network 2 network configurations 25 networking 25 O Over Temperature 37 P packaging 20 Panel Lock 40
48. ibution des adresses IP fixes sont trait es dans le manuel d installation et de fonctionnement de KUMO Achtung Beim Anschlie en von KUMO an ein standardm figes statisches IP LAN mussen Sie die KUMO Komponenten mit einer neuen einzigartigen IP Adresse konfigurieren Fragen Sie bei Ihrem Netzwerkadministrator nach wie der Anschluss erfolgen soll TCP IP statische IP oder DHCP Ihre IT Abteilung kann Ihnen zudem alle n tigen Informationen liefern die Sie zur Installation von KUMO auf einem LAN ben tigen Die Methoden zur Zuweisung von statischen IP Adressen werden im KUMO Installations und Benutzerhandbuch besprochen Precauci n Cuando conecte KUMO a una LAN de IP est tica est ndar deber configurar los componentes KUMO con una direcci n de IP nueva y nica Primero deber contactarse con su administrador de red y averiguar el m todo de conexi n IP est tica TCP IP o DHCP Su departamento de TI podr suministrarle la informaci n que necesita para instalar KUMO en una LAN Los m todos para asignar direcciones IP est ticas se presentan en el Manual de instalaci n y funcionamiento de KUMO Atenc o Ao conectar o KUMO a uma LAN padr o de IP est tico preciso configurar os componentes do KUMO com um novo endereco IP exclusivo Voc deve primeiro conversar com seu administrador de rede e descobrir como ele dever ser conectado IP est tico TCP IP ou DHCP O seu departamento de Tl estar dispon vel para fornecer as in
49. ing Bonjour e Setup and Control from a Browser on Mac OSX using a Static IP Address Windows 7 e Setup and Control from a Browser on Windows 7 using UPnP e Setup and Control from a FireFox Browser on Windows 7 using Bonjour e Setup and Control from a Browser on Windows 7 using a Static IP Address Windows XP e Setup and Control from a Browser on Windows XP using UPnP e Setup and Control from a FireFox Browser on Windows XP using Bonjour e Setup and Control from a Browser on Windows XP using a Static IP Address All of the above methods are explained on the following pages Select the method that works the best for you and your environment Important When using KUMO in a DHCP or Static IP addressed network it is best to select and maintain a consistent network scheme If a mixture of DHCP and Static IP addresses are used inconsistent performance can result The most stable operation is achieved when all IP addressing is either DHCP or Static Physical Equipment Before setting up the KUMO router s and KUMO CP panels ensure you ve got all Setup equipment interconnected direct or via LAN as already discussed 1 Connect power supplies 1 or 2 for redundancy to KUMO s 2 Connect source and destination SDI equipment this step can be deferred 3 Direct Connection connect a KUMO and a Mac or PC via an Ethernet Cable LAN Connection connect a KUMO to a hub or switch and connect a PC or Mac to the same LAN via a hub or switch
50. ing the unit Avertissement Retirez le ou les cordons d alimentation en CA de la source d alimentation principale lorsque vous d placez l appareil Warnung Trennen Sie die Wechselstrom Versorgungskabel vom Netzstrom bevor Sie das Ger t verschieben Advertencia Cuando mueva la unidad desenchufe de la red el ctrica el los cable s de la fuente de alimentaci n CA tipo brick Advert ncia Remova os cabos CA de alimentac o brick da rede el trica ao mover a unidade Avvertenza Scollegare il cavo dell alimentatore quando si sposta l unit E AJA VIDEO SYSTEMS Caution When attaching KUMO to a standard Static IP LAN you must configure KUMO components with a new unique IP address You should first talk to your network administrator and find out how it should be connected TCP IP Static IP or DHCP Your IT department will be able to supply the information you need to install KUMO on a LAN Methods for assigning Static IP addressing are discussed in the KUMO Installation and Operation manual Attention Lorsque vous branchez l appareil KUMO a un r seau LAN IP fixe standard vous devez configurer les composants KUMO avec une nouvelle adresse IP qui soit unique Vous devez d abord consulter votre administrateur r seau pour savoir comment connecter l appareil TCP IP IP fixe ou DHCP Votre service informatique pourra vous fournir les informations n cessaires pour installer KUMO sur un r seau LAN Les m thodes d attr
51. ints out KUMO connections including Power RS 422 Serial Control RJ45 Ethernet LAN Reference video and Video I O Each connection is described briefly below P S1 amp P S2 Power to the KUMO unit is supplied by a power supply brick that accepts a 110 220VAC 50 Power 60Hz power input and supplies 12 VDC to KUMO via connector PS 1 or PS2 Only one Connectors power supply is required and may be connected to either of the two power connectors An optional second power supply provides power redundancy to help protect against outages For additional protection connect the two supplies to different AC branch circuits so that KUMO will remain on even if there is a failure or open circuit breaker on one branch RS 422 DB9 KUMO includes an RS 422 female DB9 connector for making serial connections to other Connector equipment This control connection enables interoperability with other devices including those that use GVG Native Protocol For details about GVG Native Protocol please refer to the GVG document http www grassvalley jp pdf RoutingProductsProtocolManual 2 pdf RS 422 Adapter An RS 422 crossover adapter is included with the KUMO router This adapter should be attached to the RS 422 connection on the back of the KUMO router if you plan to use RS 422 protocols for remote control of the KUMO router Female Note Only KUMO routers with a serial number ending in RO require this adapter KUMO routers with serial numbers ending in
52. it System Name AJA KUMO1604 505 P Alias Type uc WARNING When you change the network configuration on your KUMO you can make it invisible to your web browser or difficult to find on your network It can take a minute or IP Address 169 254 3 87 two for the KUMO to appear in the Bonjour browsing sidebar of your web browser so Netmask 255 255 0 0 be patient before you decide it is gone If you cannot access the device you can press Default Gateway 0 0 0 0 and hold the safeboot button on the unit and when the Identify LED lights the KUMO will MAC Address 00 0C 17 87 00 1B have a temporary IP address of 192 168 101 1 and a netmask of 255 255 255 0 allowing you to connect to it there and fix any network configuration errors Update Network Settings Update Network Settings KUMO Network Setup Screen Firmware Updating AJA is constantly upgrading it s product software so it is a good idea to check the AJA website often for updates and to assure optimum system performance Go to the AJA KUMO Update page by clicking the link at the bottom of the Firmware screen Or enter this URL in your web browser http www aja com support converters converters kumo php Note Current firmware version number is reported here beneath the pull down menu DEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input is 1 AJA KUMO1604 505 d Current Firmware Version 1 1 1 25 Upload New Firmware Browse WA
53. licable AJA may include additional bulletins related to your product and software Please save all packaging for shipping KUMO should you wish to do so when moving or sending it in for service Installation and Operation Manual KUMO Router shown or KUMO CP Control Panel in electronic form on the CD PDF QuickStart Guide KUMO Shipping Box Contents In This Manual Chapter 1 Introduction lists features basic quick start information box contents and requirements Chapter 2 Getting Started details the KUMO connections and networking configuration options from closed to WAN wide area networking Illustrations point out the various connectors and indicators with text discussions of each Chapter 3 Web Browser User Interface provides complete instructions for controlling and monitoring the KUMO router from a computer Chapter 4 KUMO Remote Control Panel details the configuration and operation of the optional KUMO CP Control Panel Appendix A Specificationss lists technical specifications for the product Chapter 2 Getting Started Getting Started All of the steps for KUMO Installation and Configuration are documented in this chapter summarized as follows 1 Install the chassis in an appropriate rack If you are mounting multiple KUMO units try to place them visually in the same area so if you communicate with them via a network attached computer you can use the KUMOS Identify feature to flash the co
54. n which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Canadian ICES Statement Canadian Department of Communications Radio Interference Regulations This digital apparatus does not exceed the Class A limits for radio noise emissions from a digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications This Class A digital apparatus complies with Canadian ICES 003 R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le Reglement sur le brouillage radio lectrique du minist re des Communications du Canada Cet appareil num rique de la Classe A est conforme a la norme NMB 0
55. n the KUMO router s browser Home page with a lock icon DESTINATION 1 2 3 A 4 E lt Lockicon Dest 1 Dest 2 Dest 3 Dest 4 KUMO Router Home Page Destination Buttons Router Delegation Buttons RTR 1 4 Use the Router delegate buttons to connect to the specific router to be controlled If you are using the KUMO web browser interface you can assign the delegate buttons to any of up to four routers in your system To assign router control panel delegation you will access the Home page for your KUMO CP Shift Reset Buttons The SHIFT SRC and SHIFT DEST buttons serve multiple functions They allow you to select shifted sources and destinations 17 32 and they also perform the same reset functions as the reset slot Resets should be done only by qualified network personnel e Shift Hold down SHIFT SRC and press a source button to select a shifted source or hold down SHIFT DEST and press a destination button to select a shifted destination When a shift button is not held down pressing a source or destination button selects the unshifted source or destination 1 16 e IP Reset Hold both buttons down for five seconds to perform an IP address reset to the default IP address discussed in KUMO Quick Start in Chapter 1 e Reset to Factory Default Firmware Hold both buttons down at power up to perform a Safeboot Reset to the Factory Default firmware image ES AJA VIDEO SYSTEMS Control Panel The KUMO CP browser interface p
56. ned in this chapter Manually connecting to a network you will need to configure the KUMO IP CONFIG IP ADDR IP MASK and IP GATEWAY parameters according to the information obtained from your IT administrator in the last step Typical System Control Configurations KUMO networking possibilities range from simple to unlimited because KUMO supports e Zeroconf Bonjour and UPnP protocols e DHCP or e Static IP configuration options This section describes the following KUMO system network configurations e Small Closed or Local network with computer control zeroconf or UPnP protocol network web browser UI control any number of KUMO routers e Part of a large LAN WAN TCP IP networking DHCP or Static IP web browser UI control any number or combination of KUMO routers web browser control ES AJA VIDEO SYSTEMS KUMO In the most basic configuration a KUMO Router and a KUMO CP control panel can be set Standalone up without connecting to a computer Just use a Cat 5 Ethernet cable and apply power KUMO software automatically assigns the router to the first KUMO CP router select button RTR 1 Using a computer with Bonjour UPNP or DHCP addressing and a simple Ethernet switch you can assign up to four Router Select Buttons to control multiple KUMOs from one panel KUMO CP KUMO Router Direct Cat 5 ethernet cable connection Ethernet Switch rc Nur E e A P a an 4 4 D E E ES ES KUMO Routers im ma
57. on will be saved upon restart To set KUMO to its default static IP address 1 Power up KUMO and wait for it to boot normally 2 Fora router insert a straightened paper clip or similar device into the reset slot on the rear see photo that follows hold for six seconds and then allow KUMO to restart For a KUMO CP press and hold the two blank buttons on the panel for 5 seconds MEN JAN IDENTIFY KUMO 1616 Reset Slot Reset Buttons KUMO Reset Slot KUMO CP Reset Buttons Locations When the KUMO router default IP is set the Identify LED will illuminate and stay on When the KUMO CP default IP is set the Source and Destination buttons will flash alternately 3 Configure your PC computer to talk on the 192 168 XX XX subnet as shown below this example is for a PC connected directly to KUMO Important BEFORE altering your PC network configuration record existing TCP IP settings so that you can return your computer to normal operation after this procedure Use Control Panel to access your Local Area Network properties In Windows 7 the path is Control Panel gt Network and Internet gt Network and Sharing Center E AJA VIDEO SYSTEMS Then under Connections click on the Local Area Connection for the PC s Ethernet port AN ye Y d Control Panel Network and Internet k Network and Sharing Center Em Search Control Panel P Control Panel Horne F i View your basic network info
58. ost effective yet robust and reliable KUMO supports full broadcast specifications over SDI HD SDI and 3G SDI Kumo routers are re clocking non blocking and ready for any broadcast production or post production environment Running Embedded Linux KUMO routers support powerful HTTP control and monitoring KUMO contains an internal webserver that allows immediate installation configuration and operation without requiring additional software It offers a powerful user interface via any standard web browser KUMO SDI routers are available in two configurations e KUMO 1604 sixteen SDI inputs and four outputs e KUMO 1616 sixteen SDI inputs and sixteen SDI outputs e KUMO 3232 thirty two SDI inputs and thirty two outputs Because of their compact 1RU and 2 RU sizes KUMO SDI routers are ideal for space sensitive applications such as mobile sports trucks edit suites corporate video installations or live theatrical A V rigs E AJA VIDEO SYSTEMS KUMO Features The KUMO routers offer the following features for ease of use in any environment e SD HD 3G SDI inputs and outputs via BNC SMPTE 259M 292M 424M e Automatic equalization and re clocking e Supports all ancillary data including embedded audio e Reference via BNC passive loop PAL NTSC color black or HD tri sync e 10 100 1000 Ethernet LAN e Embedded Linux OS with internal webserver for web browser control e HTTP Control e Optional pushbutton remote control panel vi
59. pair or service the product b resulting from improper use or connection to incompatible equipment c caused by the use of non AJA Video parts or supplies d if the product has been modified or integrated with other products when the effect of such a modification or integration increases the time or difficulty of servicing the product or e resulting from being dropped or otherwise subjected to undue force exposure to moisture or other corrosive or conductive substances exposure to strong magnetic fields use with improperly regulated power supplies exposure to electric shock use in temperatures outside the specified operating range or otherwise failing to treat the product in accordance with the standard of care appropriate to sensitive and delicate electronic equipment EXCEPT AS STATED ABOVE AJA VIDEO AND ITS VENDORS DISCLAIM IN THEIR ENTIRETY ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AJA VIDEO S RESPONSIBILITY TO REPAIR OR REPLACE TIMELY REPORTED DEFECTIVE PRODUCTS IS THE WHOLE AND EXCLUSIVE REMEDY CUSTOMER IS PROVIDED KUMO Installation and Operation Manual Limited Warranty E THE PRODUCT IS NOT INTENDED STATED OR WARRANTED TO OPERATE UNINTERRUPTED OR ERROR FREE YOU UNDERSTAND AND ACKNOWLEDGE THAT THE PRODUCT IS NOT INTENDED TO BE USED AS THE SOLE OR PRIMARY DATA SOURCE OR TARGET FOR CRITICAL DATA AND THAT IT IS YOUR RESPONSIBILIT
60. r Switch see eee eee eee e aee aee ae eee aee 4 QuickStart Setup and Control Methods eee ee eee eea eea eaaa eee ee aee 5 Physical Equipment Setup ises oec naue es ya rg RD OS TRO Y RES ex a ee Co PRA d 5 Setup and Control from a Browser on Mac OSX eee eee eee rro 6 Safari Browser Using Bonjour leeeeeeeeeeeee ehe e n 6 Safari Browser Type in KUMO Static IP Address 0 ccc ccc cece cece cece een eeeeees 7 Setup and Control from a Browser on Windows 7 cece eee ee eee eee e eee e eee e ee ae eee 9 Windows 7 Using UPnP Universal Plug and Play ccc cece cece eect eee aee 9 Windows 7 FireFox Using BOnjOUr eee ccc cece III 10 Windows 7 Browser Type in KUMO Static IP Address oooooooooommmmmmmm m o 11 Setup and Control from a Browser on Windows XP cc cece cece cece cece n 14 Windows XP using UPnP Universal Plug and Play o oooooooommmmmmmmo o 14 Enabling UPnP Services in Windows XP ssss I 14 Windows XP FireFox Using Bonjour sssseeeee RII 16 Windows XP Browser Type in KUMO Static IP AddresS ooooooooooommmmmmm m o 17 Whit SIN TMG BOX etorri sora rca osos 20 In This Manual ee ee ea RR RR aee ee eaaa e eaaa ae eee aee ae eee aee aee eee 20 AJA VIDEO SYSTEMS Chapter 2 Getting Started Getting AP enue A PSU aga a ana AN a a EA a aa Ka BRA Na RN RAS 21 KUMO Chassis Installation_
61. rmation and set up connections Change adapter settings A T x See full map Ch iluanced shan i z sea EU E THADSVISTA64DEM nidentsied neok intemet This computer See also View your active networks Connect or disconnect Bonjour HomeGroup Unidentified network Access type mar Public network Connections Internet Options u Local i A 4 2 install screens X Search KONA 42 install screens g Local Area Connection 3 Properties Connection IPv4 Connectivity IPv6 Connectivity Media State Duration Speed Connect using V Intel R PRO 1000 EB Network Connection with I O Acce You can get IP settings assigned automatically if your network supports AU this capability Otherwise you need to ask your network administrator This connection uses the following items Seton id orti DM Client for Microsoft Networks vi 23005 Packet Scheduler 4 Brie File and Printer for Mm E D D AD Obtain an IP address automatically Use the following IP address IP address Subnet mask 2 453 408 oum oa m Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Default gateway Obtain DNS server address automatically 9 Use the following DNS server addresses Preferred DNS server
62. rovides the same Navigation Bar tabs as the router Browser Interface This section discusses those functions unique to the control panel interface The Navigation Bar includes e Home assign routers select buttons to KUMO routers e Configuration adjust the control panel display intensity and if necessary Reset the panel to its original Auto Configure state or to original factory settings e Network and Firmware tabs same as KUMO router network settings see Network Setup on page 34 and Firmware Updating on page 34 e Alarms Power Supply and Over Temperature refer to KUMO Alarms on page 37 e Identify button to identify the physical location of a particular control panel Home Page Use the Home page to assign a router to each of the panel select buttons Each button has a pulldown menu that lists the active networked KUMOs for assignment and provides an Unassign and Refresh function FO EN Home AJA eo Systems Apple Yahoo Google Maps YouTube Wikipedia News 143 Popularv AJA KUMO CP JSCP40 2 AJA KUMO KUMOEng1604 21 AJA KUMO KUMOEng1604 27 T VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY JSCP 40 2 KUMOEng1604 A KUMOEng1604 21 EF Unassigned M Unassigned KUMO CP Browser Interface Home Page The assigned router name appears below each button You can change the selected currently controlled router on the panel by clicking the a button on
63. rresponding LED of the unit you re communicating with Ensure you have an Ethernet cable routed to where the KUMO will be placed 2 Assemble the Ethernet network connections to a closed network or LAN using Cat 5 Ethernet cable and any required switches and hubs 3 Connect the KUMO to power connecting the power cord to mains AC 4 Cable the system SDI video source and destination equipment Three basic methods of configuring a KUMO system will be discussed later in this chapter Caution Do not defeat the safety purpose of the grounding type plug Caution To meet safety regulations for leakage current when using redundant power supplies connect the KUMO dual power supplies to separate branch circuits E AJA VIDEO SYSTEMS KUMO Chassis Installation Where to Place Plan adequate space for cable routing from the back of the chassis Ensure that SDI video KUMO cable connectors will not be stressed and that cables are not bent or crimped in the process When rackmounting or stacking multiple KUMO chassis ensure there is adequate airspace for cooling around the KUMO units Note the location of cooling vents on all equipment next to the KUMO and ensure none are obstructed Physical When planning equipment locations and mounting methods take into account the size Requirements of the router chassis e Router Dimensions 1 RU Height 1 75 4 45 cm Depth 1 5 3 81 cm Width 19 48 3 cm 2 RU Height
64. s des bouches d air de chauffage des fourneaux ou d autres appareils amplificateurs compris qui produisent de la chaleur Warnung Nicht in der Nahe von W rmequellen wie Heizk rpern Heizregistern Ofen oder anderen W rme erzeugenden Ger ten einschlie lich Verst rkern aufstellen Advertencia No instale cerca de fuentes de calor tales como radiadores registros de calor estufas u otros aparatos incluidos amplificadores que generan calor Aviso N o instale perto de nenhuma fonte de calor tal como radiadores sa das de calor fog es ou outros aparelhos incluindo amplificadores que produzam calor Avviso Non installare vicino a fonti di calore come termosifoni diffusori di aria calda stufe o altri apparecchi amplificatori compresi che emettono calore Warning Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Avertissement La s curit de la prise polaris e ou de la prise de type mise la terre ne doit en aucun cas tre emp ch e de fonctionner Une prise polaris e a deux broches l une tant plus large que l autre Une prise de type mise la terre a deux broches et une troisi me
65. s 32 KUMOHOM asian a aa a ANG KR TEBA aoe BAANG TA II BRG KE BE AREA A KAE EEA 32 Control Panel Operati0N oooooooccccncrnnccccccn BAS eaaa KE KA hh 32 Router Contigua ON aas aa aaa aana rra ERER 33 BUON SCI Sra oie CET 0 000 1002007 rada tas 33 LOCK resonar o E E EA 33 o e EU A IA 34 NetWork OUD raaa aaa Ra Aa a a TER ones apo ae 34 Film Wale UDOAUAO estabamos Ba sesos 34 adi II o aa a a NA a aa Ba aa ds 35 Uploading and Installing Firmware to KUMO see cece cette eaaa eaaa aee 35 PPP PO ROO Ga Ba Ka NE A 37 A o BI ea BA ada Ba ag an BG aa A 37 Locatndgua specie UMO saa aan qudd TA Bg a Ba a BAE NE Ra BA A E GE A BR BIN GA RR A BA 38 KUMO Installation and Operation Manual Chapter 4 Remote Control Panel KUMO Remote Control Panel 552 dione aie di it rece ee it erates 39 Connectors and Indicatof aaa aa BINASA a DE Eb ace dti aaa iris 40 BUON KEY CAPS eii sat ias 40 Panel FUNCION BHL EOS aaa aaa des ante acce utes leia eri te Mu a 40 Panel LOCK A PETERE 40 Detian LOCK ai ka gag ANG ag da e lana 41 Router Delegation Buttons RTR 1 4 ccc ccc ccc cc eee nn 41 SnifReset BUTON S susana haem eaten deme erario at 41 Control Panel Browser Interface 0 ccc ccc cece eee cence cece eee hh 42 HOMEPAGE tE ASA AAA o 42 Configuration Page a occ oor ar id 43 Centura BUON ertt Guo Spoon o qud asi 43 Appendix A Specifications K NIO SDI Router Specifications x 3L keanaan RET ERES RIETI a aa BAGA a aaa R
66. stable operation is achieved when all IP addressing is either DHCP or Static Default DHCP Configuration DHCP is the default initial configuration routine for KUMO devices If you start up on a DHCP network KUMO will accept assigned IP addresses After DHCP initialization use your zeroconf browser to view the KUMO webpage and view the assigned IP address Static IP Configuration If your LAN has a DHCP server that assigns IP addresses dynamically then you don t have to configure anything the KUMO defaults to DHCP If however your IT administrator prefers an assigned IP address that is fixed called a Static IP you will need to set network parameters using the KUMO UI Network page where you will enter e IP address type Static IP eaunique IP address e the Subnet Mask and default gateway IP address your LAN s internet router VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input Click IP Address Text to Edit a AJA KUMO1604505 WARNING Wh h h k confi KUMO k When you change the network configuration on your you can make ePOS Type once it invisible to your web browser or difficult to find on your network It can take a minute or IP Address 169 254 3 87 two for the KUMO to appear in the Bonjour browsing sidebar of your web browser so Netmask 255 255 0 0 be patient before you decide it is gone If you cannot access the device you can press Default Gateway 0 0 0 0 and hold the safeboot
67. support UPnP protocols though very often UPnP service is disabled as a default The procedure to enable UPnP is given later in this topic If UPnP is enabled you can control KUMO routers by simply going to My Network Places and double clicking on the KUMO as follows 1 Ensure KUMO to be controlled is powered up and connected via Ethernet directly or via LAN to the Windows XP PC 2 Goto Start gt My Network Places 3 Locate the Icon for the KUMO being controlled and double click it T My Metwork Places File Edit view Favorites Tools Help pack leg d ya Search Folders E Local Network y Double Click gg Add a network place H kumoEng1604 21 the KUMO Icon a View network connections Network Tasks 9 Setup a home or small office network The Internet Y Set up a wireless network For a home or small office gy View workgroup computers E My Web Sites on MSN m Hide icons For networked UPnP devices 4 Double clicking a KUMO s icon launches your Window XP PC s default browser The browser will display the KUMO web interface Use it to control KUMO If you don t see a KUMO icon under Local Network on My Network Places ensure their is either a direct connection or LAN connection and the KUMO is powered up With those requirements satisfied if no Icon can be seen then likely the UPnP services are disabled Enabling UPnP Services in Windows XP 1 Go to Start Control Panel and then click A
68. t The configuration of the KUMO prior to the upgrade is preserved Verify the new software is running by bringing up the KUMO web page again Check the Firmware page for the current version number The restart and refresh cycle may take a couple minutes If for some rare reason it didn t update you can then run through the update steps again Note On some browsers the Retry page may appear even though the software upgrade was successful If this occurs before clicking on retry refresh the web page and check the version number If the new version number appears at the top of the page the software upgrade was successful If the old version appears Click Retry If there is a power outage or glitch during the software download the KUMO will boot the older software version and the upgrade process can then be re started by the user This happens because the KUMO has been designed with a safety feature where an internal safe copy of the previous software is retained in the event the updating process fails KUMO Installation and Operation Manual Router Web Browser User Interface Safeboot Reset If your KUMO software becomes corrupted to the point of freezing the device you can always reset to the initial factory installed safeboot firmware image by following these steps 1 Power down the KUMO 2 Press and hold the reset button by inserting a paper clip or other device in the reset slot on the back of KUMO 3 Apply power to the ro
69. t avec un tissu sec Warnung Das Ger t nicht in der N he von Wasser verwenden und nur mit einem trockenen Tuch s ubern Advertencia No utilice este dispositivo cerca del agua y l mpielo solamente con un pa o Seco Aviso N o utilize este dispositivo perto da gua e limpe o somente com um pano seco Avviso Non utilizzare questo dispositivo vicino all acqua e pulirlo soltanto con un panno asciutto Warning Do not block any ventilation openings Install in accordance with the manufacturer s instructions Avertissement Ne bloquez aucune ouverture de ventilation Suivez les instructions du fabricant lors de l installation Warnung Die L ftungs ffnungen d rfen nicht blockiert werden Nur gem den Anweisungen des Herstellers installieren Advertencia No bloquee ninguna de las aberturas de la ventilaci n Instale de acuerdo con las instrucciones del fabricante Aviso N o obstrua nenhuma das aberturas de ventilac o Instale de acordo com as instruc es do fabricante Avviso Non ostruire le aperture di ventilazione Installare in conformit con le istruzioni del fornitore KUMO Compact SDI Routers Before operating your KUMO unit please read the E Warning Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Avertissement N installez pas l appareil pr s d une source de chaleur telle que des radiateur
70. telligent and communicates via standard straight through CAT 5 ethernet cables or null modem cross over cables without any configuration or strapping required Note Tested and supported browsers include e Firefox latest version 3 6 3 on all platforms e Safari latest version MAC and Windows e E 7 8 latest versions Windows e Chrome latest version on all platforms ES AJA VIDEO SYSTEMS Navigation Bar The KUMO web browser user interface UI provides a navigational bar of tabs for Information access to five control screens and the Identify toggle button e Home control panel for source destination selections e Configuration custom naming for sources and destinations e Network IP settings for LAN WAN operation e Firmware update menu for KUMO software from AJA e Alarms log of service failures e Identify toggles activation of Identify LEDs for easy location of various system components VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input KUMO Navigation Bar Click any of the first five tabs to jump to that screen To the right of the Identify button you will see the detected format of the Reference Video signal being used if signal is present KUMO Home From the Home screen you can use the pulldown menu in the upper left to see all of the KUMO routers present on the local LAN and select the one you want to control or monitor Control Panel Opera
71. that the product will be free from defects in materials and workmanship for a period of five years from the date of purchase If a product proves to be defective during this warranty period AJA Video at its option will either repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product To obtain service under this warranty the Customer must notify AJA Video of the defect before expiration of the warranty period and make suitable arrangements for the performance of service by contacting AJA Video support through the channels set forth on the support contacts web page at http www aja com support index php Except as stated the Customer shall bear all shipping packing insurance and other costs excluding parts and labor to effectuate repair Customer shall pack and ship the defective product to a service center designated by AJA Video with shipping charges prepaid AJA Video shall pay to return the product to Customer but only if to a location within the country in which the AJA Video service center is located This warranty shall not apply to any defect failure or damage caused by negligent inadequate or improper use handling or maintenance Without limiting the foregoing AJA Video shall not be obligated to furnish service under this warranty or repair any damage or malfunction a resulting from attempts by personnel other than AJA Video representatives to install re
72. the SDI signals being switched or any reference input connected to the router EH AJA VIDEO SYSTEMS KUMO CP Specifications Control 10 100 1000 Ethernet RJ 45 internal Linux OS web server Environment Operating Termperature 0 to 40 Degrees C Relative Humidity O to 90 non condensing Power 12VDC nominal 9 18 VDC range optional redundant power KUMO CP 4 Watts Size KUMO CP Depth 1 07 27 3 mm Height 1 72 43 7 mm Width 19 483 mm Weight KUMO CP 1 2 Ib 55 kg Appendix B Safety 8 Compliance Federal Communications Commission FCC Compliance Notices Class A Interference Statement FCC Caution This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 Subpart B of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commericial installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense If this equipment does cause harmful interference to radio or television receptio
73. tion Immediately below the KUMO selection menu are the Source input buttons Below the Source input buttons are the Destination output buttons Click on any Destination and it will highlight and cause it s currently selected Source button to illuminate VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input AJA KUMO1604 505 SOURCE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Source Source2 Source3 Source4 Source5 Source6 Source7 Source8 Source9 Source 10 Source 11 Source 12 Source 13 Source 14 Source 15 Source 16 DESTINATION KUMO Web Browser Control Panel Note In Configuration you can hide Destination buttons that are not wanted for control from your location see Router Configuration on page 33 KUMO Installation and Operation Manual Router Web Browser User Interface ES Router Using the Configuration screen you can click on the name fields to assign custom Configuration Source and Destination names to the inputs and outputs of the router VIDEO SYSTEMS HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input Click button text to edit right click for more options SOURCE 1 2 a 5 9 10 11 12 13 14 15 16 Sat Src2 Src5 Src Src9 Src10 Src11 Src12 Src13 Src14 Src15 Src16 Com Clckhere Clik here Glick hero Clckhere Click here Clik hero Click hero Clickhere Clik here Click here Click here Clickhere Click here Click here Click here DESTINATION
74. uter and after a moment release the reset Note A Safeboot Reset is also available for the KUMO CP see Shift Reset Buttons on page 41 RS 422 gz ANJA PIS1 S IDENTIFY PS2 UU KUMO O 10 100 1000 LAN 1616 Reset Slot KUMO Rear Panel and Reset Slot KUMO Alarms Kumo reports alarms on the router front panel by lighting an Alarm LED and in the web browser UI by illuminating the border of the Alarms tab see below Alarms include e Power Supply displays error condition if a redundant power supply is off line e Reference displays error condition if no valid video reference signal is found e Over Temperature displays error if KUMO exceeds normal operating temperature HOME CONFIGURATION NETWORK FIRMWARE ALARMS IDENTIFY Reference No Input AJAKUMO1604 505 Normal Over Su Power Supply Reference Temperature gt Sync Error None PS Error Fly down Menu KUMO Web Interface Alarms Screen If you do not want any of the above conditions to report an error right click Control Opt click to access the fly down menu shown above Select Suppress to deactivate the specific alarm ES AJA VIDEO SYSTEMS Locating a Specific Click on the Identify button to flash the Identify LEDs on the front and back panels of KUMO the KUMO router enabling quick physical location of the router in a populated rack of equipment Click again to turn it off Identify LE lt front panel Identify LED rear
75. web browsers have been tested and approved for use with KUMO e Firefox latest version 3 6 3 on all platforms e Safari latest version MAC and Windows e E 7 8 latest versions Windows e Chrome latest version on all platforms Bonjour capability is recommended Once connected you can use a web browser to e Configure any TCP IP settings e Select and name KUMO routers and control panels e Name sources and destinations e Make Source to Destination assignments signal routing e Set a variety of operational and monitoring options Bonjour software is built into Apple Macs with OS X from version 10 2 onward and can be installed onto Windows PC computers Bonjour for Windows adds zero configuration capabilities to Internet Explorer and with the addition of the Bonjour Foxy plug in to Firefox KUMO Installation and Operation Manual Typical System Control Configurations ES Please note that KUMO supports both zeroconf Bonjour and UPnP protocols but does not require them For example you can connect a PC without Bonjour by simply performing a KUMO default IP address reset and pointing your browser to the address Then you can set it up using the KUMO browser UI Network page to set standard TCP IP settings discussed in detail in TCP IP Network Connection on page 28 If the KUMO will be attached to a WAN talk to your IT administrator and obtain the details on how he she wishes you to configure the KUMO DHCP or static IP explai

Download Pdf Manuals

image

Related Search

Related Contents

WinDASI: A Software for Cost Benefit Analysis of Investment Projects  SUPER-X PRO  Manual de Instruções  CYCLONIC VACUUM CLEANER USER GUIDE Model no  AEG LAVATHERM 57700 User's Manual  「Astell&Kern AK120 TITAN(タイタン)」    09 Equipos de Proteccion Individual.p65  Hewlett Packard Enterprise A 5120-24G-HPoE  