Home
GeoLogik TRT
Contents
1. Analysis Calculation of Borehole Thermal Resistance The Thermal Resistance is calculated at the time of the first fluid exchange in the BHE after the heating power is switched on It is your task to specify this point of time The program suggests a time based on the volume and the flow rate _ Vols Volg aa V with Vols Volume of tube Vol Volume of TRT device V Flow rate if a variable flow rate is given the program uses an averaged value The equitation used to calculate the Thermal Resistance R is with Q Heat flow A logarithmic mean temperature difference at the time of fluid exchange This equitation looks quite simple but we want to explain some details here too Logarithmic mean temperature difference The logarithmic mean temperature difference AS is defined as Uy Ur AU in 5 1 Ur Vy with Sy Temperature in Temperature out y Temperature of undisturbed underground Heat flow The Heat flow Q is defined as Qn gt mit Q Heating Power W H Tube length m Heating Power The Heating Power Q is calculated by using the temperature difference Q pCpV dy Up with 2011 GeoLogik Software GmbH 20 GeoLogik TRT 2 2 2 p Density of fluid kg m Cp Specific heat capacity of fluid kJ kg K V Flow rate of fluid m s When calculating the Thermal resistance R the program uses the flow rate at the time of the
2. GeoLogik Software s GeoLogik TRT User manual Thermal Response Test Analysis Software 05 2011 END USER LICENSE AGREEMENT FOR GEOLOGIK SOFTWARE S TRT Software IMPORTANT READ CAREFULLY This GeoLogik Software GmbH End User License Agreement EULA is a legal agreement between you either an individual or a single entity LICENSEE and GeoLogik Software GmbH for the software product s accompanying this EULA which include s computer software and may include online or electronic documentation associated media and printed materials SOFTWARE PRODUCT By installing copying or otherwise using the SOFTWARE PRODUCT or any UPDATES as defined below you agree to be bound by the terms of this EULA If you do not agree to the terms of this EULA do not install copy or use the SOFTWARE PRODUCT and promptly return the entire unused SOFTWARE PRODUCT to your place of purchase for a full refund In addition by installing copying or otherwise using any updates or maintenance releases that you have received as part of the SOFTWARE PRODUCT UPDATES you agree to be bound by the additional license terms that accompany such UPDATES If you do not agree to the additional license terms that accompanies such UPDATES you may not install copy or use such UPDATES SOFTWARE PRODUCT LICENSE Copyright laws and international copyright treaties as well as other intellectual property laws and treaties protect the SOFTWARE PRODUC
3. 1 151 0 0196 17 18 00 1 1297 0 0073 Filter Import all 5 By difference in time Minute By difference in data m h 4 0 02 Click on Next to continue with importing the Heating power 1 Select Import power 2 Click on the last column because it contains the power information This is not obvious from the first measurements since the values are quite small and even negative 3 The power values in the logger file are given in kW That is the reason for the small values Since we have selected W in the beginning of that lesson change the Unit logger file to kW now 4 Import power Unit Jogger file kW Click on the column with the POWER 13 07 2008 17 08 00 1 1142 12 2 12 1 0 2 13 07 2008 17 09 00 1 1216 123 12 2 05 13 07 2008 17 10 00 1 1205 12 2 12 1 0 0313 We are going to import all data points So just leave the default Filter settings to Import all Click on Next to continue with importing the temperatures 1 Select Import temperatures The is no need to change the Unit C 2 Click on the 4th column to select it as Temperature in O 2011 GeoLogik Software GmbH Tutorial 29 3 Click on the 5th column to select it as Temperature out 4 Import temperatures Unit logger file Click on the two columns with IN and OUT TEMPERATURES 13 07 2008 17 08 00 1 1142 H 124 0 1602 E 13 07 2008 17 09 00 1 1216 3 0 0327 We will also import all tempe
4. BHE The data is automatically sorted by time regardless of the input sequence If duplicated time values the program informs you about it and deletes the duplicates The columns AT In and AT lin display the logarithmic and linear temperature difference to the underground The column Q contains the power level which is calculated using the T in and T out values assuming a averaged flow rate If Reference reading is selected the table contains time temperature values This can be used to document other relevant parameters e g the outside air temperature 2011 GeoLogik Software GmbH Reference 15 2 1 4 1 2 1 5 Filtering data points The button Filter is located above the table It is used to enable or disable filtering of the data points If the filter is enabled the color of the button changes to inform the user that not all the data points are visible j Import Import Logger data E Excel data 1 4 ia 12 2 0 14 0 15 129 2 13 12 1 12 2 0 0 05 179 Filter enabled If you click on the small triangle on the right side of the button the command Filter settings becomes visible If you select it the following dialog appears Filter settings Filter Type By change in time A t Minute By change in value A Celsius 0 2 Now you can select the Filter type which can be By change in time or By change in value Enter a applicable A in the text box next to it Importing l
5. 0866 o 1400 op e 4200 5600 7000 12 427 1 1273 Flow rate For a simple case select constant and enter the flow rate in the text box next to it The data table becomes active if you select variable The instrument position of the flow meter is used by the program when calculating the power level from difference in temperatures This is because both density and specific heat capacity are functions of temperature and depending on the instrument position the values will be calculated using either inlet or outlet temperatures 2 1 3 Entering Heat power The Heat power is entered on the page Power level Heating power W Power on min 41 Constant power level Power off min 3817 O Variable power level Heat injection rate 66 6 W m Import Import Logger data x Excel data Time min Power w a 1 32 7 2 2 31 3 13 3 29 7 4 14 44 z 5 5 212 3 Fi 6 6 296 7 2500 u 7 160 3 ls 8 171 3 99 19 6 10 10 7 3 1 u 32 3 T a a a 7000 12 12 17 9 Time min 13 113 159 7 a Power level For a simple case select Constant power level and enter the value next to it If Variable power 2011 GeoLogik Software GmbH 14 GeoLogik TRT 2 1 4 level is selected the table becomes active If you do the analysis later on you can select if the power level is taken from the measurements entered here of if it is calculated by using the differences in temperatures Enter the times for Power on and Power
6. 09 00 1 1216 12 3 12 2 0 0327 6 13 07 2008 17 10 00 1 1205 122 12 1 0 0313 Click on Next to continue Now the separator is selected which is used to split the data into columns Seperators Tab El Semicolon Comma E Space E Others 2011 GeoLogik Software GmbH 28 GeoLogik TRT Select the Tab as a separator and click on Next Now the column holding the date information is selected 1 Click on the first column The column header changes to Date 2 You can keep the Date format DD MM YY if it shows up otherwise change it to that format It will import correctly even if the year has 4 digits Click on the column with the DATE 2 pate format DD MM YY x Click on Next Now the column with the time information must be selected Click on the 2nd column and then on Next 1 Check the box Import Flow rate because we want to import that data 2 Click on the 3rd column which holds the flow rate information 3 Ensure that the Unit logger file is set to m h 4 We will not import all data In the Filter section select By difference in data and enter 0 02 m h as threshold 4 E Import flow rate Unit Dogger file im ah Click on the column with the FLOW RATE 17 08 00 1 0 1602 17 09 00 1 0 0327 17 10 00 1 0 0313 17 11 00 1 1094 0 0297 17 12 00 1 1374 0 044 17 13 00 1 1299 0 2123 17 14 00 1 1535 0 2967 17 15 00 1 1261 0 1603 17 16 00 1 1199 0 1713 17 17 00
7. 11 00 1 1094 0 0297 13 07 2008 17 12 00 1 1374 0 044 13 07 2008 17 13 00 1 1299 0 2123 13 07 2008 17 14 00 1 1535 0 2967 13 07 2008 17 15 00 1 1261 0 1603 13 07 2008 17 16 00 1 1199 0 1713 13 07 2008 17 17 00 1 131 0 0196 13 07 2008 17 18 00 1 1297 0 0073 13 07 2008 17 19 00 1 1315 0 0323 13 07 2008 17 20 00 1 1151 0 0179 13 07 2008 17 21 00 1 1219 0 1597 13 07 2008 17 22 00 1 1236 0 16 Selecting the date column Now click on the column containing the date information The Date format can be set in the combo box in top right corner if it is different from the date format set in Windows D means day M means month and Y means year Click on Next to continue to select the applicable column for the Time Like the date column simply click on the column containing the Time information Click on Next to continue f Import Logger data Y Import flow rate Unit logger file m3h Click on the column with the FLOW RATE Date Time 13 07 2008 17 08 00 12 2 12 1 0 1602 13 07 2008 17 09 00 1 1216 12 3 12 2 0 0327 13 07 2008 17 10 00 1 1205 12 2 12 1 0 0313 13 07 2008 17 11 00 1 1094 12 3 12 2 0 0297 13 07 2008 17 12 00 1 1374 12 3 12 1 0 044 13 07 2008 17 13 00 1 1299 12 2 12 1 0 2123 13 07 2008 17 14 00 1 1535 12 2 12 2 0 2967 13 07 2008 17 15 00 1 1261 12 2 12 2 0 1603 13 07 2008 17 16 00 1 1199 12 2 12 2 0 1713 13 07 2008 17 17 00 1 131 12 2 12 1 0 0196 13 07 2008 17
8. 1374 23 12 1 0 044 13 07 2008 17 13 00 1 1299 12 2 12 1 0 2123 13 07 2008 17 14 00 1 1535 12 2 12 2 0 2967 13 07 2008 17 15 00 1 1261 12 2 12 2 0 1603 13 07 2008 17 16 00 1 1199 12 2 12 2 0 1713 13 07 2008 17 17 00 1 131 12 2 12 1 0 0196 13 07 2008 17 18 00 1 1297 12 2 12 1 0 0073 Filter Import all gt By difference in time Minute By difference in data J 0 1 Importing temperatures Now you have to click twice because the first click will select the Temperature in and the second the Temperature out If you have selected the wrong column simply click a third time to select Temperature in again and a forth time for the Temperature out and so on Click on Next to continue with importing reference reading e g the outside air temperature That screen works like the screens before Click on Next to start the importing process The process indicator keep you informed about the import and show the number of imported data points 1 Import Logger data y Import flow rate data Finished Imported 503 of 504 data points Import heat power data Finished Imported 503 of 504 data points Import temperatures O Finished Imported 275 of 504 data points Importing reference temperatures 0 Completion of import Click on Close to end the Import wizard 2011 GeoLogik Software GmbH Reference 19 2 2 2 2 1
9. Analyses Ferbornstr 19a Project GeoLogik TRT Tutorial en www geologik com Client Rich Ltd i GeoLogik Software GmbH Hesting period 41 min to 3817 min min C C m h W In the picture above the zoom factor is set to Page width You can do this by clicking on the appropriate icon or selecting Page width from the combo box In the preview you can see in the top right corner of the page that the document has 9 pages Use the buttons Previous Page and Next Page to browse Selecting a printer The program starts to print immediately if the Print icon is clicked no dialog is shown If you want to select a different printer or change the print settings select File Printer Setup from the menu Do this now and select a printer you want to use for our example A total of 12 pages will be printed so we recommend using a PDF driver instead of a real printer Selecting the reports Check the Data node and the Analyses node in the tree view and click on Print In case you are printing to a PDF driver The program will create 4 documents one for the data 2011 GeoLogik Software GmbH Tutorial 35 report and one for each analysis we have 3 of them Some PDF drivers provide an option to conflate these documents into a single document so you have to distribute only one PDF file for the TRT 2011 GeoLogik Software GmbH 38 GeoLogik TRT Appendix 4 1 Technical Support
10. PRODUCT THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY HAVE OTHERS WHICH VARY FROM STATE JURISDICTION TO STATE JURISDICTION CUSTOMER REMEDIES GEOLOGIK SOFTWARE GmbH s ENTIRE LIABILITY AND YOUR EXCLUSIVE REMEDY SHALL NOT EXCEED THE PRICE PAID FOR THE SOFTWARE PRODUCT NO LIABILITY FOR DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL GEOLOGIK SOFTWARE GmbH OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION OR ANY OTHER PECUNIARY LOSS ARISING OUT OF THE USE OF OR INABILITY TO USE THIS GEOLOGIK SOFTWARE GmbH PRODUCT EVEN IF GEOLOGIK SOFTWARE GmbH HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES BECAUSE SOME STATES JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY TO YOU MISCELLANEOUS This Disclaimer and Limitation of Liability are governed by the laws of Germany If this product was acquired outside Germany then local law may apply Should you have any questions concerning this EULA or if you desire to contact GeoLogik Software GmbH for any reason please contact in writing GeoLogik Software GmbH Ferbornstr 19a 35619 Braunfels Germany Content 3 Content Teil 1 2 3 Teil Il 1 3 Teil Ill ar Q N Teil IV First Steps Installation Asa ee
11. Your graphic should also be square otherwise it will be stretched If Big Logo is selected the entries under company name will not be displayed Instead the full space is occupied by the graphic The aspect ratio depends on the settings for the page margins The title block always has a height of 2 5 cm the width of the graphic is half of the page width minus the page margins Example calculation The paper size is A4 21 cm width left margin is 2 cm and right margin is 1 cm Therefore the width of the graphic is 9 cm 21 cm 2 cm 1 cm 2 The aspect ratio width height of the graphic should be 9 2 5 e g 1080 x 300 pixel The settings for the title block are program settings and will not be saved along with the TRT file 2011 GeoLogik Software GmbH 10 GeoLogik TRT Reference Data entry All data use the units from the tab Thermal Response Test Units Y Convert Length m Temperature c y Length Dia mm Power w Time min y Flow rate mm Setting units If you realize during data entry that a wrong unit was selected uncheck the Convert box and change to the correct unit Keep in mind that the units apply to all data in the active TRT The default units which are used if you create new files or TRTs can be set on the tab Environment under Tools Options There are three pages to enter the measurements Flow rate Power level and Temperatures They all have the same layout
12. at about 41 min and switched off at 3817 min Enter this two values in the text boxes above the table 2011 GeoLogik Software GmbH 30 GeoLogik TRT 3 2 l Heating power W Power on min 41 Power off min 3817 Temperatures Go to the page Temperatures Enter 12 1 C as the Undisturbed ground temperature Resize the window to have a better look at the data table In the column Q the program displays the Power based on the difference in temperatures Rows where the data is within the heating period appear in a different color Temperature measurements C Undisturbed ground temperature C 12 1 In Out Name Reference reading Import Import Filter Logger data x Excel data reduce datapoints v Time min T im C T out C AT n C AT in C Q w 3 Y 34 12 3 12 2 0 14 0 15 129 135 138 12 2 12 2 0 1 0 36 139 12 2 12 2 0 1 0 ae 137 40 12 2 12 2 0 1 0 2 38 4 16 8 12 1 0 2 35 6065 5 39 122 16 9 12 1 0 2 4 6194 5 40 143 16 8 12 1 0 238 6065 E 41 4 16 9 12 1 0 2 4 6194 42 45 16 8 12 2 1 19 2 4 5936 43 46 16 9 12 2 1 21 2 45 6065 144 47 16 9 12 3 1 45 25 5936 45 48 16 9 12 3 1 45 2 5 5936 T q ee gr 5 6 49 17 12 2 123 u 6194 Time min 47 50 16 9 12 3 1 45 25 5936 a e Inflow Outflow By now all required data is entered into the program The next lesson shows how to create the documentation of the TRT Creating the documentation This
13. da Intr duction va Customizing the title block Reference Data entry Entering BHE data sica ee Send BHE to Profil Tec Entering FIOW rate Gites Rai Entering Heat power ccccecceeeeeeeeeeeseeeeeeeeeeneneeeeenees Entering Temperatures Filtering data points Importing logger data cooocccnnccocnconcnconncnonaronannnnnos Analysis Calculation of Borehole Thermal Resistance Calculation of Thermal conductivity and Heat capacity Effective radis dr loto ici Printing reports uns Tutorial Entering and importing data Creating the documentation Determining Thermal resistance Calculating underground parameters Printing reports concocnconcccnoconononanonanonnnnonnronanonanos Appendix Technical Support ROTeOrences tia Index 2011 GeoLogik Software GmbH 6 GeoLogik TRT 1 First Steps 1 1 Installation O System Requirements e Windows XP Vista or higher e At least 50 MB free hard disk space e Mouse or other pointing device Installing GeoLogik TRT Installing GeoLogik TRT on a Local Drive from CD e Insert the CD ROM in the CD ROM drive Navigate to the folder TRT on the CD and run SETUP EXE Installing GeoLogik TRT on a Local Drive Using a Downloaded EXE e Navigate to the folder containing the downloaded file e Double click the downloaded file to begin the installation process The installation file is digitally signed to protect it from unauthor
14. file is created or the borehole is appended to an existing Profil Tec file In any case the program prompts you to specify a file name If the option Open file after create is checked Profil Tec will open after the process is finished and display the selected file The following data will be transferred e Name and location of BHE e Depth and diameter of borehole e Grout material e Tube e if you have selected Create new file the project details project name project number client will be transferred too The scale of the borehole will be set in a way that it fits on a A4 sized page Optimizing the well completion diagram in Profil Tec if the labels for grout material and borehole overlap click on Align labels wizard icon if the label for the grout material reads Zementation Click on it an uncheck Default Labeling in O 2011 GeoLogik Software GmbH Reference 13 the panel Appearance This function required a licensed version of Profil Tec 6 3 or higher 2 1 2 Entering Flow rate The flow rates are entered on the page Flow rate Flow rate m h Instrument position constant o before heater behind heater variable y j S og r j ee E Import ogger data Excel data Time min Flow rate m gt h 2 1 Lo 1 1216 2 6 1 1535 7 1 1261 4 143 1 1037 ee 5 202 1 1351 6 217 1 1016 E ae 7 232 1 0608 8 247 1 1075 0 4 19 322 1 0859 10 367 1 1091 11 412 1
15. fluid exchange or the next value later there is no averaging of flow rate Fluid characteristics GeoLogik TRT supports 5 fluids 1 Water 2 Propylene glycol 25 3 Propylene glycol 33 4 Ethylene glycol 25 5 Ethylene glycol 33 Density and specific heat capacity are functions of temperature If the program takes the T in or T out to calculate them depends on the given Instrument position for the flow rate Density of fluid The program uses a polynomial within a temperature range of 0 to 100 C Specific heat capacity of fluid Within a temperature range of 0 to 100 C the program uses a polynomial of 1 degree Table interpolation is used for water Calculation of Thermal conductivity and Heat capacity The calculation can be done using either line source of cylinder source model To switch the model click on the link at the bottom of the results panel Using cylinder source L D 1769 2 change to line source If the cylinder source is used the ration L D is displayed whereas L tube length and D 2 x effecive radius The cylinder source model required much more CPU power thus the program might react slower The calculation time to depends also on the number of data points It can be a good idea to filter the data points Line source The Difference in temperature AQ is a function of the radius r and time t and is given by 2 A0 r t On 3s Ei 5 with Q Heat flow Rg Thermal resistance A Thermal c
16. lesson is based on the data entered in the previous lesson Select Analysis Create documentation from the menu The program will select the page Analysis automatically Expand the panel Display on the right hand side of the graph and apply the following settings Display AT linear Fiona fe Foner mesra Y Reference temperate The program will draw a marker for every data point Since we have a lot of data points it is recommended to hide the markers Expand the panel Diagram and set the value of Marker size to 0 Changes become visible if you hit the Return Enter key of leave the text box To show a legend select bottom for the option Legend which is also in the panel Diagram In case the legend overlaps with the graph increase the value for Lower margin e g to 15 mm Axis scaling The temperature axis scales from 10 to 30 C which is a good range for the sample data 2011 GeoLogik Software GmbH Tutorial 31 Eventually the intervals of the axis labeling are not nice e g every 4 C 10 14 18 etc To change this set the Major unit in the panel Temperature axis to 4 Change the Value format to 0 0 to display only one digit after the decimal separator The Value format uses 0 for a digit which is displayed always The is used for an optional digit The dot is used as the placeholder for the decimal separator set up in Windows On the Time axis the Maximum is set to Auto thus the m
17. on the page Environment 2011 GeoLogik Software GmbH Tutorial 27 Entering BHE data Geometry and fluid are specified in the panel Borehole Heat Exchanger For our sample enter the data below Borehole Heat Exchanger Name BHE 1 r mm 78 him 92 Lim 92 me I 1 1 oOo E d mm 32 s mm 3 ud In that case we use a Double U type BHE and Water as fluid That is all for now on the page Thermal Response Test Importing data In this example the data comes from a data logger file To start importing locate the Tasks section in the panel Analyses and click on Import Logger data Analyses Performed analyses E New analysis 1 Tasks 4 Define analysis time range Fj Import Logger Data g Send BHE to Profil Tec In the File open dialog browse to the SAMPLES folder select the file TRT Tutorial TXT and click on Open Now the Import Logger data wizard shows up 1 Click on the 4th row in the table to specify the beginning of the data Import starts at row 2 Set the Test start t 0 to 13 July 2008 at 17 08 00 h i A a E Import Logger data El x File C Users Public Documents TRT Beispiele TRT Tutorial bet Import starts atrow 4 File format ANSI Preview Test start t 0 13 07 2008 17 08 00 Br 2 1 GeoLogik TRT Tutorial 2 3 Date Time Flow rate m3 h Temperatur in C Temperatur out a t 13 07 2008 17 08 00 1 1142 122 12 1 0 1602 5 13 07 2008 17
18. with a data table and a diagram The diagram serves as a visual control for the data Click on a data point in the diagram to jump to the corresponding data entry in the table GeoLogik TRT uses the decimal separator set up in Windows With the Enter key the cursor moves to the next cell in the table There is no need to enter the data in chronological sequence because the program sorts the data by time Duplicated points of time are not allowed If duplicated time values occur only the first will be taken and the others will be ignored All time values are time since the Test Start The Test Start is defined as the beginning of recording measurements and must be before the heat power is switched on This point of time must be entered on the page Thermal Response Test TRT Name TRT 1 Conducted by Geotechnik Lehr Time period 13 17 July 2008 Test start 13 07 2008 17 08 00 Br Test start 2011 GeoLogik Software GmbH Reference 11 2 1 1 Entering BHE data The panel Borehole Heat Exchanger BHE is located on the tab page Thermal Response Test and is used to enter construction details l Borehole Heat Exchanger 1 E Name BHE 1 cy r mm Radius of borehole required hm Depth of the borehole Lim Tube length required Typ 4 i d mm Tube diameter required s mm Tube wall thickness required Puid water Panel Borehole Heat Exchanger The following parameters are us
19. 15 Teststart 10 Flowrate 13 Thermal conductivity 20 33 Fluid exchange 19 32 Thermal resistance 19 20 32 Full version 6 U H Units 10 Heat capacity 20 33 Heating power 13 5 V a Volumetric heat capacity 20 inflow 14 W Installation 6 L Well completion diagram 12 License number 6 Line source model 20 Logger data 15 0 outflow 14 outside air temperature 14 2011 GeoLogik Software GmbH
20. 18 00 1 1297 12 2 12 1 0 0073 Filter 9 Import all By difference in time Minute By difference in data m3 h Ge Importing Flow rate To import flow rate data select the Import flow rate checkbox Ensure that the correct unit is selected in the combo box in the top right corner Then click on the column containing the flow rate information Below the table you can see the panel Filter The meaning of Import all should be clear If you select By difference in time or By difference in value and enter a difference the program will import data points only if the difference from the previously imported data point is reached Typically this will reduce the number of data points imported often making the analysis clearer Click on Next to continue to importing Heat power data This screen works exactly like the one before Check the box if you want to import set the correct unit click on the column with the data Click on Next to continue with importing temperatures O 2011 GeoLogik Software GmbH 18 GeoLogik TRT 1 Import Logger data Y Import temperatures Click on the two columns with IN and OUT TEMPERATURES Date Time Flow rate Tin T out Heat Power 13 07 2008 17 08 00 1 1142 12 2 121 0 1602 13 07 2008 17 09 00 1 1216 12 3 112 2 0 0327 13 07 2008 17 10 00 1 1205 12 2 12 1 0 0313 13 07 2008 17 11 00 1 1094 23 12 2 0 0297 13 07 2008 17 12 00 1
21. T The SOFTWARE PRODUCT is licensed not sold The SOFTWARE PRODUCT consists of product documentation sample applications tools and utilities and miscellaneous technical information individually identified as COMPONENT and collectively as COMPONENTS The rights regarding the COMPONENTS of the SOFTWARE PRODUCT are described below unless otherwise indicated 1 GRANT OF LICENSE GeoLogik Software GmbH grants to you as an individual a personal nonexclusive nontransferable license to make and use copies of the SOFTWARE PRODUCT in the manner provided below If you are an entity GeoLogik Software GmbH grants to you the right to designate one individual within your organization to have the right to use the SOFTWARE PRODUCT in the manner provided below You may use this SOFTWARE PRODUCT on a networked system provided that the number of SOFTWARE PRODUCT users on the network at one time does not exceed the number of licensed copy ies of the SOFTWARE PRODUCT GeoLogik Software GmbH retains title and ownership of the SOFTWARE PRODUCT or any copy 2 COPY RESTRICTIONS This SOFTWARE PRODUCT and the accompanying COMPONENTS are copyrighted Unauthorized copying of the SOFTWARE PRODUCT including any part of the SOFTWARE PRODUCT that has been modified merged or included with other software or of the COMPONENTS is expressly forbidden You may be held legally responsible for any copyright infringement that is caused or encouraged by your failure to abide by the t
22. Technical support for GeoLogik TRT can be obtained e on our website www geologik com e via phone 49 0 64 42 96 21 73 e via E mail info geologik com Desktop Sharing We also provide desktop sharing as a special service to getting support You need to have an Internet connection to use it During a desktop sharing session the screen content is transferred either your screen to GeoLogik or vice versa The conversation takes place via phone To start a desktop sharing session select Help Desktop Sharing from the menu and follow the instructions Start Desktop Sharing Session Online Desktop Sharing Use this function to look at the desktop of GeoLogik Software You need an Internet connection to establish a connection Call this phone number 49 0 6442 962173 to contact technical support Click here to start the Desktop Sharing Software Enter the session nummber you have obtained from GeoLogik technical support Close window 4 2 References Loose P 2007 Erdwarmenutzung 2 Aufl C F M ller Heidelberg O 2011 GeoLogik Software GmbH Index 39 Index PDF 34 _ A _ Power level 13 Printer setup 23 Printing 23 34 airtemperature 14 Profil Tec 12 _ C _ Propylene glycol 19 R Cylinder source model 20 A D 5 Radius 22 Reduce data points 15 Register 6 Data report 23 Reports 23 E ii Effective radius 22 Support 38 Ethylene glycol 19 T F temperatures 14 Filter
23. ace TRT Tutorial English GeoLogik TRT y File Edit Test Analysis Tools Ha New Open eySave Print Copy Paste X Delete Refrestf SS SS I Click here to show or hide fields Navigation y Analysis Thermal conductivity W m K S Underground parameters Name Underground parameters Endosure 2 404 a Tasks Performed by Date 08 02 2010 v hL Define analysis time range 7 Comments Volumetric Heat Capacity MJ m3K Import Logger Data p 3 Send BHE to Profil Tec 5 25 A Time since first fluid exchange min 1 10 100 1000 10000 Fit to data points RB 0 22mK W Change RB Qh 66 6 W m r 26 mm Analysis graph Change method or define analysis time range Using line source change to cylinder source T E 10 50 3 Time axis y N un Temperature axis Diagram Panels for formatting the analysis AT measured AT calculated Copyright GeoLogik Software GmbH amp Geotechnik Lehr 2009 2010 Status bar U eee Navigation panel In this panel you can see all performed analyses and common tasks at the bottom by clicking on Tests the view changes allowing to select a different TRT Tab pages The program has 6 tab pages It is a good idea to work through them from left to right Depending on the active page different elements appear on that page The picture above shows the page Analysis On that page you can s
24. allows to select the reports for printout All reports checked in the tree view will be printed as soon as you click on Print 2 F Determine RE W Underground parameters Printing begins immediately no dialog will show To change printer settings or to select another printer click on File Printer Setup before starting to print The program has two types of reports e Data e Analyses The data report show all recorded data in chronological sequence Data for Heat power and fluid flow rate also appear in the data report if they are variable When tey are constant the values are shown in the header section of the report Print Preview Page width a O 7 Previous Page J Next Page GeoLogik Software GmbH Thermal Response Test S 1v 9 Ferbornstr 19a Project GeoLogik TRT Tutorial gen www geologik com Client Rich Ltd Locstion Braunfels TRT TRT 1 Conducted st BHE 1 Conducted by Geotechnik Lehr Time range 13 17 July 2008 Undisturbed ground temperature 12 1 C Test start 13 07 2008 17 08 00 Data report with temperatures flow rates and power levels 2011 GeoLogik Software GmbH 26 GeoLogik TRT 3 1 Tutorial In this Tutorial you will learn how to enter the data of an TRT and how the analysis is performed The data in this example are based on a really conducted test The steps in detail e Entering and importing data e Creating the documentation e Determining Rg e Calculatin
25. are GmbH if you fail to comply with any provision of this EULA Upon termination you shall destroy the written materials and all copies of the SOFTWARE PRODUCT previously licensed to you 6 UPDATES AND UPGRADES GeoLogik Software GmbH may create from time to time updated versions of the SOFTWARE PRODUCT At its option GeoLogik Software GmbH will make such updates available to the LICENSEE If the SOFTWARE PRODUCT is being licensed to you as an update or upgrade to a SOFTWARE PRODUCT previously licensed to you you must destroy the SOFTWARE PRODUCT previously licensed to you including any copies resident on your hard disk drive s within sixty 60 days of the purchase of the license to use the update or upgrade 7 SUPPORT SERVICES GeoLogik Software GmbH may provide you with support services related to the SOFTWARE PRODUCT Support Services Use of Support Services is governed by the GeoLogik Software GmbH policies and programs described in the user manual online documentation and or GeoLogik Software GmbH provided materials Any supplemental items provided to you as part of the Support Services shall be considered part of the SOFTWARE PRODUCT and subject to the terms and conditions of this EULA With respect to technical information you provide to GeoLogik Software as part of the Support Services GeoLogik Software may use such information for its business purposes including for product support and development GeoLogik Software will not utilize suc
26. axium value displayed is 7000 Change it from Auto to 6000 and enter 6 as the Major unit Now every 1000 a number label is displayed Expand the panel Power axis and change the Major unit to 4 and the Maximum to 8000 W In the panel panel Flow Axis change the Major unit to 3 and the Maximum to 1 5 m h Report preview The diagram now looks pretty clear Go to the Reports tab and have a look at the Print preview Select the Documentation from the tree view 2 Data FE Analyses i E New analysis 1 i E Documentation Sometimes the axis label draw beyond the frame 8000 6000 4000 2000 0 T m Power calculated In that case go back to the Analysis tab open the panel Diagram and increase the value for the Left Margin e g to 25 mm Go back to the print preview it should look like this O 2011 GeoLogik Software GmbH 32 GeoLogik TRT 3 3 Print Preview Full page X O 7 Previous Page J Next Page GeoLogik Software GmbH A Ferbornstr 19a J 35619 Braunfels 8 www geologik com Heating period 41 min 3817 min Time since test start min 2000 3000 4000 5000 Temperature C Flow rate m h z y 3 0 a o E a E T in T out Flow rate Power measured Power calculated Double U BHE Fluid Water Length 92 m Diameter 32 mm Tube wall thickness 3 mm Borehole Depth 92 m Diameter 156 mm Determining Thermal resistan
27. ce This lessen continues the previous chapter Select Analysis Determine RB from the menu The program changes to the Analysis tab and the diagram looks quite good already Now you can 1 shift the straight line by clicking on it and holding down the left mouse button to change time for the first fluid exchange or 2 entering a numerical value for the time of the first fluid exchange 3 change the Device volume TRT device tubes to the BHE the default volume is set under Tools Options on the Device tab This value is used to calculate the theoretical duration and has no direct impact on the calculation of Rg 2011 GeoLogik Software GmbH Tutorial 33 Thermal Response Test Flow rate Power level Temperatures Analysis Reports Click here to show or hide fields RB Calculation Analysis Fluid exchange after min Name Determine RB Endosure 11 44 Performed by Date 08 02 2010 Theoretical duration 11 44 min Tube volume 0 195 m Comments 3 ee volumne 0 020 m RB 0 22mK W Time since Power on min Estimated Power 6072 W 0 30 Time axis Temperature axis Diagram Width mm Height mm Left margin mm 4 Yv nd Upper margin mm Right margin mm Lower margin mm Legend Legend Font Marker size Line width Temperature C T in T out As described in the previous chapter you can change axis scaling and preview the repor
28. ed in the calculation of results r Radius of borehole L Tube length d Outer diameter of tube s Tube wall thickness Fluid Type of BHE In case of a coaxial BHE also the inner tube diameter di and the inner wall thickness si are required gt Entering additional data for the BHE Click on Additional data to enter location information x y altitude and grout material F Selecting an existing BHE Click on Select BHE to show all BHEs in the project 2011 GeoLogik Software GmbH 12 GeoLogik TRT 2 1 1 1 BHE in project Create new Delete Select a BHE for a TRT Name Tube length m Tube type x m Used BHE GEHE 1 92 Double U 146 Unused BHE BHE 2 2 Double BHE 3 06 Single U BHEs in project The currently selected BHE is marked with a green icon To select another BHE double click it or select it with the mouse and click on Select in the menu This window is also used to create a new BHE or to delete an existing BHE Send BHE to Profil Tec A BHE can be transferred to the borehole logging software Profil Tec If you select Tools Send BHE to Profil Tec a dialog will prompt you for the target location Send BHE to Profil Tec i Create BHE in a new file or use an existing file Specify destination location Create a new file gt Append to existing file Cancel I Open file after creating BHE Selecting destination of the BHE in Profil Tec Either a new Profil Tec
29. ee the Analysis graph the Results panel and additional panels for formatting the diagram Data structure GeoLogik TRT is a file based application similar to a word processing or spreadsheet software A single file i e a project can contain several TRTs and boreholes BHE There is no need to create a new file for every TRT you can simply select Test New TRT to add a TRT to the project If you create a new TRT the program automatically adds a new BHE Click on Select BHE on the page Thermal Response Test to open a dialog for managing the BHEs 2011 GeoLogik Software GmbH GeoLogik TRT 1 3 Customizing the title block After the installation name and logo of GeoLogik Software appear in the title block To set your own company name and logo select Tools Options from the menu go to the tab Reports and look for the panel Title block Title block W Display title block Company name GeoLogik Software GmbH ron Ferbornstr 19a 35619 Braunfels www geologik com lt Logo Preview a None 8 Small Big File name IE C Program Files GeoLogik GeoLogik TRT j In the text box Company name you can enter your own company name Click on Font to change font style and size In the Logo panel you can select a graphic file We recommend a Windows Bitmap BMP with a resolution of at least 300 dpi If Small Logo is selected the graphic will show up as a square on the left side of the company name
30. erms of this EULA Subject to these restrictions you may make one 1 copy of the SOFTWARE PRODUCT solely for backup purposes You must reproduce and include the copyright notice on the backup copy You may not copy the printed materials accompanying the SOFTWARE PRODUCT or print multiple copies of any user documentation 3 USE RESTRICTIONS As the LICENSEE you may use the SOFTWARE PRODUCT on one computer at one time and place You may not distribute copies of the SOFTWARE PRODUCT to others You may not modify adapt translate reverse engineer decompile disassemble or create derivative works based on the SOFTWARE PRODUCT You may not modify adapt translate or create derivative works based on the written materials without the prior written consent of GeoLogik Software GmbH 4 TRANSFER RESTRICTIONS This SOFTWARE PRODUCT is licensed only to you the LICENSEE and may not be transferred to anyone without the prior written consent of GeoLogik Software GmbH Any unauthorized transferee of the SOFTWARE PRODUCT shall be bound by the terms and conditions of this EULA Enabling others to use your registration code s or serial number s is strictly prohibited In no event may you transfer assign rent lease sell or otherwise dispose of the SOFTWARE PRODUCT on a temporary or permanent basis except as expressly provided herein 5 TERMINATION This EULA is effective until terminated This EULA will terminate automatically without notice from GeoLogik Softw
31. g underground parameters e Printing reports All sample files are located in the folder TRT SAMPLES under the Public files folder Entering and importing data Start the program GeoLogik TRT After start up the program already contains an empty file and project On the page Thermal Response Test enter the following information into the panels Project and TRT Project Project name GeoLogik TRT Tutorial Project No 1 Client Rich Ltd Location Braunfels TRT Mame TRT 1 Conducted by Geotechnik Lehr Time period 13 17 July 2008 Test start 13 07 2008 17 08 00 Br The only real hard information which is used for calculating is the Test start value because all time information is given as elapsed time since test start For now you do not have to enter the value given above because it will be set later on All other entries can be changed as you like because they serve as information only However do not leave them blank because it is easier to located them on the report if they are filled out Setting the units Look for the panel Units and set them as shown below fi Units Y Convert Length Im Temperature sc Length Dia mm Power w Time min Flow rate m ath Length is used for location of the borehole and the tube length L nge Dia is used for the geometry of the BHE i e radius of borehole and diameter and wall thickness of the tube Tip Under Tools Options you can set the default units
32. h technical information in a form that personally identifies you 8 COPYRIGHT All title and copyrights in and to the SOFTWARE PRODUCT the accompanying printed materials and any copies of the SOFTWARE PRODUCT are owned by GeoLogik Software GmbH The SOFTWARE PRODUCT is protected by copyright laws and international treaty provisions Therefore you must treat the SOFTWARE PRODUCT like any other copyrighted material except that you may either a make one copy of the SOFTWARE PRODUCT solely for backup or archival purposes or b install the SOFTWARE PRODUCT on a single computer provided you keep the original solely for backup or archival purposes You may not copy the printed materials accompanying the SOFTWARE PRODUCT 9 UPDATE LICENSE TERMS Additional license terms may accompany UPDATES By installing copying or otherwise using any UPDATE you agree to be bound by the terms accompanying each such UPDATE If you do not agree to the additional EULA terms accompanying such UPDATES do not install copy or otherwise use such UPDATES DISCLAIMER OF WARRANTY NO WARRANTIES THE SOFTWARE PRODUCT IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW GEOLOGIK SOFTWARE GmbH AND ITS SUPPLIERS DISCLAIM ALL WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY AGAINST INFRINGEMENT WITH REGARD TO THE SOFTWARE
33. hrzeit Durchfluss m3 h Vorlauftemperatur C 4 13 07 2008 17 08 00 1 1142 12 2 12 1 0 1602 5 13 07 2008 17 09 00 1 1216 12 3 12 2 0 0327 Y Import Logger data first step In the first step you specify the beginning of the data using the Import starts at row text box To do this you can also simply click on a row in the table Also the Test start is displayed and you can modify that value if is is not correct Click on Next to continue 1 Import Logger data Seperators Tab Space Others Conflate consecutive seperators 17 08 00 1 1142 0 1602 13 07 2008 17 09 00 1 1216 0 0327 13 07 2008 17 10 00 1 1205 0 0313 13 07 2008 17 11 00 1 1094 0 0297 13 07 2008 17 12 00 1 1374 0 044 13 07 2008 17 13 00 1 1299 0 2123 13 07 2008 17 14 00 1 1535 0 2967 13 07 2008 17 15 00 1 1261 0 1603 13 07 2008 17 16 00 1 1199 0 1713 13 07 2008 17 17 00 1 131 0 0196 13 07 2008 17 18 00 1 1297 0 0073 Selecting separators During the next step separators used to split the data into separate columns are selected Date and time must be in separate columns Click on Next to continue O 2011 GeoLogik Software GmbH Reference 17 r Import Logger data Click on the column with the DATE Date format DD MM YY Date 2 3 13 07 2008 17 08 00 1 1142 0 1602 13 07 2008 17 09 00 1 1216 0 0327 13 07 2008 17 10 00 1 1205 0 0313 17
34. ized modifications The installation program guides you through the installation process Installing GeoLogik TRT requires that you be logged into an account that has Administrator rights Registration Registration is required to use the software as full version Under Windows Vista Windows 7 GeoLogik TRT must be started with Administrator rights to successfully complete the registration process To do this right click on the GeoLogik TRT program icon and select Run as administrator from the popup menu If prompted by UAC then click on Yes to apply permission to allow the program to run with full permission as an administrator Click on Help About and afterwards on the link Register Click here to register GeoL gil Cathars Register Enter your Company name and Licence number The licence number has 4 blocks with 4 characters each GeoLogik Software GmbH 2009 wo geologik com info genlagik com Company name GeoLogik Software Licence number KICK YYYY rife Vay 2011 GeoLogik Software GmbH First Steps 7 Close the Register dialog with OK and you should see a message that the registration was successful Information s You hawe sucsessfully registered the program Please restart the application Click on OK in the message box and click once more in the About window to close it You must restart GeoLogik TRT to use it as full version 1 2 Introduction GeoLogik TRT User interf
35. off because they are required Time values must be given in Time since Test start In case of variable power level it is required that a data point with t gt Power off is given in the table Entering Temperatures Temperatures are entered on the page Temperatures Temperature measurements C Undisturbed ground temperature C 12 1 O In Out Reference reading Name f Import E Import Y Filter d E Logger data Excel data reduce datapoints Time min T in C T out C AT n C AT in C Q w Z 31 31 12 2 12 2 0 1 0 A 32 12 2 12 2 0 1 0 Ba 33 12 2 12 1 0 0 05 129 34 34 12 3 12 2 0 14 0 15 129 z 18 35 38 12 2 12 2 0 1 0 3 136 39 12 2 12 2 0 1 0 5 37 40 12 2 12 2 0 1 0 E 38 41 16 8 12 1 0 13 6065 39 42 16 9 12 1 0 2 4 6194 40 43 16 8 12 1 0 2 35 6065 41 44 16 9 12 1 0 2 4 6194 142 45 16 8 12 2 1 19 2 4 5936 o q an es Lm 43 46 16 9 12 2 1 21 2 45 6065 Time min 44 47 16 9 12 3 1 45 25 5936 5 e Inflow Outflow Temperatures A required input is the Undisturbed ground temperature If In Out is selected the table contains data triples i e measurements containing time inflow and outflow temperatures If the data for a point of time is incomplete if either inflow or outflow is missing the data will no be accepted by the program and are deleted on the next refresh of the table T in means inflow i e the fluid entering the BHE T out means outflow i e the fluid leaving the
36. ogger data A logger data file contains the measurements in the format of Date Time and Measured Data The data must be in chronological sequence starting with the earliest time Click on Import Logger data above the table or in the task panel to start the process After you have selected the file the Import Logger data wizard appears Die Messungen m ssen in chronologischer Reihenfolge vorliegen Um diese zu importieren klicken Sie auf Logger Daten importieren im Aufgaben Panel oder auf eine die Schaltfl che Importieren von Logger Daten oberhalb der Eingabetabellen Es ffnet sich dann der Dialog zur Auswahl der Logger Datei und danach der Import Assistent 2011 GeoLogik Software GmbH 16 GeoLogik TRT 1 Import Logger data ____ iim ri File C Users Public Documents Thermal Response Tests Beispiele TRT Tutorial Import starts atrow 4 y Preview Test start t 0 13 07 2008 17 08 00 6 13 07 2008 17 10 00 1 1205 12 2 12 1 0 0313 z 13 07 2008 17 11 00 1 1094 12 3 12 2 0 0297 8 13 07 2008 17 12 00 1 1374 12 3 12 1 0 044 9 13 07 2008 17 13 00 1 1299 12 2 12 1 0 2123 10 13 07 2008 17 14 00 1 1535 12 2 12 2 0 2967 jaa 13 07 2008 17 15 00 1 1261 12 2 12 2 0 1603 12 13 07 2008 17 16 00 1 1199 12 2 12 2 0 1713 jas 13 07 2008 17 17 00 1 131 12 2 12 1 0 0196 14 13 07 2008 17 18 00 1 1297 12 2 12 1 0 0073 R cklauftemperatur Ey ja GeoLogik TRT Tutorial a 2 3 Datum U
37. onductivity a Thermal diffusivity A pC Thermal conductivity volumetric heat capacity Ei Exponential integral 2011 GeoLogik Software GmbH Reference 21 Cylinder source The Difference in temperature A9 at z 0 half height of cylinder is Ilu Erf 5 75 du Qu 1 pe Ad r t gt Rg 7 a with modified Bessel Function 0 order Erf Gauss error function L Length of cylinder 2r gt The equitation above cannot be solved analytically In the program the solution is obtained by numerical approximation Variable heat power calculation applying the principles of super position For a line source applies Ry de Ad t Oy ee ve Ei 5 S Ou Qui ES lp with Q Heat flow starting at t 0 Q Heat flow of i th step n number of steps What happen if Fit to data points is clicked If you click on Fit to data points the program modifies the parameters Thermal conductivity and Specific heat capacity in a way that the sum of squared errors is minimized Y AP ness Adrneo gt min GeoLogik TRT uses a numerical optimization algorithm 2011 GeoLogik Software GmbH 22 GeoLogik TRT 2 2 2 1 Effective radius The difference in temperature between Fluid and underground is a function of the radial distance r In the results panel the utilized r is displayed 1 Results Thermal conductivity W m K 2 404 a Volume
38. rature data so you do not have to change the Filter setting Click on Next to continue with importing reference reading There is no data for it so uncheck Import reference reading and click on Next to start the import A 317 The last screen will inform you about the success of the import process Import flow rate data 0 E Finished Imported 106 of 504 data points Import heat power data A Finished Imported 503 of 504 data points Import temperatures Finished Imported 503 of 504 data points Importing reference temperatures 0 Click on Close to exit the Import Logger data wizard Flow rate Back in the main window go to the page Flow rate It looks like this Thermal Response Test Flow rate Power level Temperatures Analysis Reports Flow rate m h Instrument position constant before heater behind heater variable I S J PB a Import Import Logger data EJ Excel data Time min Flow rate m h 1 1 1216 vc 2 66 115 3 7 1 1261 4 4 1 1037 2 5 202 1 1351 6 217 1 1016 E ga 7 232 1 0608 8 247 1 1075 0 4 9 322 1 0859 10 367 1 1091 0 11 412 1 0866 o 1400 2800 N a 4200 5600 7000 12 427 1 1273 n If it is not already set change the Instrument position to before heater Power level Go to the page Power level If you scroll down in the data table you will find out that the Power is switch on
39. ses the time after the first fluid exchange as a starting point and the power off of the heater as the ending point 7 You can also change the calculation model here The default model is the line source Be aware that the program becomes slower if you select the cylinder source since the calculation Is more time consuming 8 Click on Comments to write remarks for the analysis O 2011 GeoLogik Software GmbH 34 GeoLogik TRT Thermal Response Test Flow rate Power level Temperatures Analysis Reports Click here to show or hide fields Results f Analysis d Thermal conductivity W m K Name Underground parameters Endosure 2 2 404 A Performed by Date 08 02 2010 v A Comments Volumetric Heat Capacity MJ m3K A G 5 25 A 1 Fit to data points RB 0 22mK W Change RB 4 Qh 66 6 W m ry r 26 mm a ee 5 change metho 6 je efine analysis time range 5 Using line source 4 change to cylinder source Time axis 4 Temperature axis gt Diagram AT measured AT calculated This chapter ends the lessons about analyzing a TRT 3 5 Printing reports Assuming you have worked through the previous lesson click on the Reports tab now In the tree view click on Data to see the print preview of the report Thermal Response Test Flow rate Power level Temperatures Analysis Reports Data Print Preview Page width O Previous Page J Next Page
40. t 3 4 Calculating underground parameters This lesson is based on the data entered in the previous lesson Select Analysis Determine Thermal parameters from the menu The program will select the page Analysis automatically Now you can 1 Perform an automatic Fit This will change Thermal Conductivity and Volumetric Heat Capacity in a way that deviation from the data points is minimized Click on Fit now to do it 2 The Thermal Conductivity can be changed by entering a numerical value in text box You can also use the slider control below the text box The graph is updated automatically In the semilog view below the change of the thermal conductivity changes the slope of the straight line section 3 The same applies to the Volumetric Heat Capacity In the semilog view below the change of the Volumetric Heat Capacity will shift the line vertically The button with the padlock on it will lock a parameter so it will not change if a automatic Fit is performed 4 Click on Change RB to select a Thermal resistance or to enter it 5 If you click on Change method a dialog will show up providing options for the calculation For example the program can either calculate the heating power from the differences in temperatures or use directly measured data Also the value for the effective radius can be set here 6 Another option is to define an analysis time range This allows you to select a different interval in time by default the program u
41. tric Heat Capacity MJ msK 5 25 a Fit to data points RB 0 22mK W Change RB Oh 66 6 W m r 26 mm Change method or define analysis time range Click on Change method 2 to show the the dialog Method of calculation The following options are available for the radius Radius The effective radius is used to calculate the difference in temperature Please select one of the following options gt rfe U tube E Diameter of tube r e Double U tube C Custom value Radius of borehole Millimeter r e U tube r e Double U tube tw 2 5 s with d outer diameter of tube S wall thickness of tube Radius of borehole Diameter of tube r d Custom value You can enter your own value for r here When you create a new analysis using Analysis Determine Thermal parameters the program uses r e U tube or r e Double U tube depending on the Type of BHE already selected If the Type of BHE is changed later existing analyses are not effected You need to change them manually 2011 GeoLogik Software GmbH Reference 23 2 3 Printing reports You can view and select reports for printout on the page Reports The zoom factor can be set in the combo box above the print preview There are also buttons for the Full page and Page width zoom factors If a report contains multiple pages e g data report you can browse through using Next Page and Previous Page buttons The tree view on the left side
Download Pdf Manuals
Related Search
Related Contents
Teka DX 90 Samsung Galaxy S4 med 4G+ Bruksanvisning Talha Servo Manual de utilização Télécharger USER GUIDE - Systems Telecoms Un traitement novateur, efficace et confortable des verrues adsl - Orange TV MODE D`EMPLOI WERABAL/T 29.07.97 Temps de prdparation: env Origin Storage 250GB 7.2K SATA Copyright © All rights reserved.