1. eene 38 Appendix ROO etr ker no en cenar ene ce conr a ne n encor ree s ce in 39 Notes for the application in the food industry ssssseeeeeees 39 Cleaning reference BEOO0 iio toa eee px rne seeds tus 39 Cleaning recommendations for special areas essssssseeeee 41 Recommendation cleaning agents RFood sssseeeeeeeeeee 44 Appendix RR300 Plus FR nui uice ra rnnt rau uu rat unn suu onu e rura nuno onu eua ru cuna 45 Radar motion detector RR300 Plus F R sssssssseeeeeeeeeeneennes 45 Reference Sells oderit a Ar dst eundi ea aei dades 45 Installation of the additional F R components cccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 45 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 4 1 1 1 2 1 3 1 4 1 5 1 6 ASSA ABLOY Introduction These operating instructions apply to the use of the following doors with associated control units RR300 RR300PLUS RRClean RFood RR200 RR355 RR392 RR450 RR500 RR600 RR3000 R GL XXL ISO They constitute part of the product and describe how to use the product properly and safely throughout the product life cycle Applicable documents The operating instructions are only valid in combination with the operating instructions for the control unit and the inspection book Both of these documents are supplied with the product A supplement to the operating instructions which is a
2. N eo eo o o1 c6 x lt X x o o1 c6 RR3000 GL top side frame RR3000 R side RR3000 ISO XXL top roll RR3000 ISO XXL side frame nN RR3000 R top Ci o roll N N eo RR3000 GL Co A o A Co eo C1 N eo N Q O1 Ojo NIQ ojo palette completely wrapped with plastic material Undamaged packing allows storage 6 4 2 Storage The partly preassembled door is being delivered on a transport resp mounting of the door outside of buildings for several days 6 5 Disposal The packing material of the door may be returned to the manufacturer Defect door components should be disposed of at the site according environmental regulations Defect electronic components should be disposed to special waste disposal 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 26 A Appendix ASSA ABLOY The following tables list technical data for the doors A capsule summary of the maximum opening and closing speeds is also provided in Section A 3 A1 Technical Data Doors with flexible curtains Albany RR300 Albany RR300 Plus Door principle Roll door Roll door Running direction vertical vertical Application Interior door Interior door Wind class 1 1 Available sizes W min 500 mm 1000 mm W max 4000 mm 5000 mm H min 500 mm 1000 mm H max 4200 mm 5000 mm Drive electrical electrical Mains power See control unit manual See cont
3. movement of the door The photocell must be checked at least half yearly by technical personnel 2 5 2 2 5 2 1 Additional protection systems Sensors Depending on the kind of door application it may be advisable to utilize additional sensors for protection reasons This is valid for instance for applications involving a high frequency of human traffic as well as with low dimensioned doors less than 3 m in height and therefore no optical awareness given for the closing door as an additional protection ASSA ABLOY Entrance Systems offers a big variety of further protection systems for high speed doors light curtain motion sensing detectors floor loops etc For individual cases we suggest consultation with an Albany Door Systems representative at the application site At doors with a height of H lt 2 5m a top roll cover is absolutely necessary With the RR600 the top roll cover is specified as mandatory for heights less than or equal to 2 3 m 2 5 2 2 Emergency manual lever except RR200 RR300 RR500 RRClean and opt RFood At power loss repair and maintenance work may become necessary to open the door manually 1 Byusing the emergency manual lever on the side frame the brake of the drive motor can be released via a disengagement cable 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 9 2 5 2 3 ASSA ABLOY Depending on the counterweight set up and the door position the door blade may parti
4. Pulley cable and belt Pulley and steel cable Sound pressure level 70 dB A 70 dB A 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 31 ASSA ABLOY A2 Technical Data Doors with rigid curtains Albany RR 3000 3000GL 3000R 3000 ISO 3000 XXL Door principle Roll door Running direction vertical Application Exterior and interior door Wind class 3 3 3 2 4 2 U value 1 5 W m K Available sizes W min 600 mm W max 5000 mm 5000 mm 6000 mm 7000 mm 8000 mm H min 3125 mm 2500 mm 1500 mm 2500 mm 2500 mm H max 6000 mm height increment 5000 mm 5000 mm 3000 mm height increment 6000 mm 125 mm 100 mm Drive electrical Mains power See control unit manual Motor performance 1 1 kW Control unit MCC Control voltage 24 V DC Operating temperature 10 C 40 C range Motor protection IP55 Side frame galvanized steel Anodized aluminum slats some with windows Peer conan ae DE PETERT with steel sheets RAL 9006 Optional with double glazed windows Lifting device Flat belt with reinforcing steel ropes belt Sound pressure level 70 dB A 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 32 ASSA ABLOY A3 Maximum opening and closing speeds MCC ACS50 MCS ACS25 O O O O O O O O RR200 2 0 0 6 RR300 2 0 1 0 1 0 0 8 0
5. QN o0 gt gt lt O c3 c S5 o Inspection riag clo o oc ococ gplo 9o wNMjo oilojoio jo Oo oO t 0 0 t 0 o ojo ojo eieiloleoe ojeljisxivol cdaliaeleo c tc rclju dm ada cz cdc dc inmiai ac e cca nene jdcydcinmiajiazc Control box and additional attachments e g impulse activator Check for full number completeness of circuit alala ala 4 diagrams Check main switch CEE plug and control box lock 4144 4 4 4 4 4 4 4 4 4 Check the fixing 414 4 4 4 4 4 4 4 4 4 4 Electrical components Visual inspection for mechanical damage 11112 1 1 1 1 1 1 3 2 2 Check potential balance 414 4 4 4 4 4 4 4 4 4 4 Safety equipment and impulse activators Measure self opening height after switching off the door and document in the inspection logbook T5 minimum self opening height 2m Check self test function by switching the key switch 1 or switching the door On Off Function Check function of safety edge photocell additional 1 17 1477 7 774 7 47771471 safeties and actuators Check function and condition of the torque arm tla lolalalalalalatslele during operation Assess possibility of emergency opening TE I SELL A ED CD fl Pel 8a ee Check opening and closing position of the bottom tlalelalalalalalalslele profile Check winding performance of door curtain and tia lolalaladalalalslele ropes belts Check function of belt and spring break switch 1 Check function of magnetic switch at 2m door height 1 Check radar motion detectors for m
6. Therefore is an earthing screw in the area of the drive unit or in the lower part of the side frame on the drive side which is marked with an earth symbol 5 4 Dismantling To dismantle the door follow the installation instructions in reverse order 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 22 6 2 6 2 1 ASSA ABLOY Life Cycle Installation See the user guide for the associated control unit Maintenance and Cleaning In case of necessary work of maintenance malfunction repair please ask your supplier or manufacturer of the door ASSA ABLOY Entrance Systems Albany Door Systems GmbH Service Department Am Mondschein 25 59557 Lippstadt Germany Tel 49 0 2941 766 0 Fax 49 0 2941 766 294 Internet www albanydoors com Email service de albany assaabloy com Safety instructions The maintenance and inspection work must only be performed by manufacturer trained authorized personnel 6 2 2 e Before performing any maintenance and cleaning work disconnect the door from the mains by switching off the lockable main switch on the switch box or unplugging the CEE connector Also observe the instructions in Section 2 5 2 4 Uninterruptible power supply UPS e Use ameter or other test device verify that the switch box is de energised e Please observe that all used ladders scaffoldings or such correspond with the valid safety regulations e The working area must be blocked for traffic Lu
7. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 CO NI NIN Oo NN amp O01 O1 NN NU G A O71 CO Ni GD KO CO CO OO CO O OO H OO POPPE POPP PO PO IO TPO POTD POTD FDO PDO PO DO PO PO IO PY PO ISO PO IO IO O IO IO ISO I O PO IO PO PO A ARDARBIEARA ARA RIAGR BR BR BR ON OO OO OO 9o o o o o o Oo j NIN w CO amp GC CO amp CO C9 C O2 CO 02 CO 02 GO GC CO CO a a CO Go CO CO CO DOP POP POPP PO PO POPP O TO O TO IO TO TO IO TO ITO PY PY PO PO PO 2 ALA Af Popa Py H H HLH HIHIHISHAIHAIHIHIHIHAIHIHAIHIH HHA HHH HLH HLH HHL HIRSH HIRI RIA DMMP O PO DO PO O IO PO IPD PO SO O O PO TP PO O O PO IO PO IO PO IO O IO IDO IO IO PO C Aa N D A The values given give the number of indexing steps of the radar antenna which is to be set from Position 0 90 E2 Installation of the additional F R components 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 45 ASSA ABLOY The radar motion detector is installed in the factory in the top roll cover of doors with H 3700mm In doors with H 3700mm a separate bracket is supplied for the radar motion detector this must be installed in the middle above the door The maximum allowable installation height for the
8. 8 0 8 RR300 Plus 2 2 0 9 1 2 1 2 RRClean 2 0 1 0 1 0 1 0 HFood 2 2 1 0 1 0 1 0 RR392 2 2 0 9 0 8 0 8 RR450 2 2 0 9 0 8 0 8 RR500 0 8 0 4 RR600 ot 1 2 RR3000 2 2 0 7 RR3000 R 2 0 0 6 RR3000 ISO 2 1 0 7 RR3000 GL 1 8 0 7 RR3000 XXL 1 8 0 6 Depending on door size 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 33 ASSA ABLOY B Appendix Inspection The following tables list inspection plans for the doors The overview of the service intervals are provided in section B 1 The numbers are used in the inspection plan O Information for RRClean doors for GMP relevant aspects are provided in section B 2 B1 Service intervals half yearly or 50 000 cycles only for RR300 Plus F R annually or 50 000 cycles annually or 100 000 cycles annually clean if necessary every 4 years 150 000 cycles co jo Cci 2c n b5o 250 000 cycles co 500 000 cycles e 150 000 cycles RR300 Plus F R 100 000 cycles with MCC 150 000 cycles with ACS50 50 000 cycles N RR450Ex 600Ex 200 000 cycles C2 150 000 cycles RR450Ex 600Ex 50 000 cycles ENS A 200 000 cycles RR600 Crash 100 000 cycles C1 DH 3m 500 000 cycles DH 2 3m 250 000 cycles Oo DH 4m 300 000 cycles DH 2 4m 200 000 cycles Exchange of bearings only by drive manufacturer or an approved workshop for the maintenance of t
9. against accidental re activation or reconnection CAUTION Risk of personal injury and material damage Door movements during cleaning could cause injuries or material damage c Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection 3 Open side frame Loosen the lock screw which is located in about 1m height at the front of the side frame 1 turn Move the lock screw a few mm to the side Pull the locking lever and push upwards Then swing open the side frame cover 4 Open top roll cover Loosen both screws at the front side of the top roll cover Do not remove the screws from the top roll cover Pull the top roll cover forward This swings the top roll cover forward and upward and remains open in the topmost position 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 42 ASSA ABLOY e Use a water hose for cleaning e Do not use high pressure cleaning machine 5 Check cleanliness of the rope and the rope discs and clean if required A clean damp cloth can be used to support the cleaning 6 Close the top roll cover and secure with the lock screw 7 Switch on main power 8 Carry out test run D 2 1 5 Cleaning inside the motor cover 1 Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection
10. and health of persons as well as for machine material or environment The advice assembled directly at the control box and the door must be noticed and kept in readable condition at all times Warning notices in this document are formatted as follows SIGNAL WORD N Danger Consequences gt Precautions If the danger is an electrical hazard the appropriate pictogram is used SIGNAL WORD N Danger Consequences gt Precautions The following warning levels are used ORO Hazard ievel rene dM Danger Immediate grave danger Death or serious physical injury WARNING Potential immediate grave danger Death or serious physical injury CAUTION Potential hazardous situation Minor physical injuries material damage This symbol leads to information explaining the various door operations Important information 1 6 2 Operation concept Aim of the operation 1 Step Result of the step optional 2 Step Result of the step optional 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 6 2 2 ASSA ABLOY Safety General safety advice These operating instructions contain important information for commissioning operating transporting storing and maintaining the door safely and properly e Please read the operating manual carefully and keep it at a safe place for further use e Take particular note of the information in this section Also note the specific safety in
11. 2 Catching device with solenoid actuators The door has catching device which ensures an opening height of 2 m in the event of a fault occurring and simultaneous power failure This function is provided by a solenoid actuator installed at a height of 2 m in the side frame on the drive side If a voltage is applied to this switch the traverse path for the slider of the bottom profile is released if the voltage fails the solenoid actuator locks the traverse path in the Close direction In normal operation of the door a voltage is applied to the solenoid actuators and the traverse path for the slider is released If a fault is detected e g a spring breaks the door is electrically moved to the top limit position and switches to fault If a fault occurs in this situation the curtain unwinds and the bottom profile moves downwards However if the power supply fails the solenoid actuator blocks the traverse path of the bottom profile and the bottom profile is stopped at the height of the solenoid actuators and an opening height of 2m remains Regular self tests of the door To ensure the exit and escape route functions self tests are performed after switching on after the escape route deactivation has ended see Chap 2 6 5 after 24 hours and after a power failure 8 00 am is preset in the factory as the time for performance of the self tests This time can be changed to the user s needs using the display unit When the self tests are
12. CAUTION Risk of personal injury and material damage Door movements during cleaning could cause injuries or material damage c Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection 2 Remove motor cover Remove the screw on the bottom and two screws on the outer side of the motor cover Then pull the motor cover forward e Water and a clean damp cloth can be used for the cleaning e Do not use high pressure cleaning machine 3 Check cleanliness of the drive unit the cables and the attaching parts and clean if required A clean soft brush with plastic bristles can be used to support the cleaning 4 Push the motor cover back and screw tightly 5 Switch on main power 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 43 ASSA ABLOY D 2 2 Recommendation cleaning agents RFood This recommendation was compiled in co operation with the companies Tana chemistry GmbH T www tana de and Johannes Kiehl KG K www kiehl group com These companies made extensive studies of the resistance of the door materials Recommended cleaning agents are listed below daily routine maintenance cleaning Basic cleaning Intensive cleaining Method Product Method Product alkaline surface Kraftreiniger T cleaning Torvan Konzentrat FD K Alkaline cleaning Nowa FLA 710 S T Nowa Tanin T Grasse
13. Clean outer surfaces with cleaning agent and disinfectant Clean side frames chapter D 2 1 2 Clean top roll cover chapter D 2 1 3 BT ue og Clean rope for counterweight system chapter D 2 1 4 6 Carry out test run Basic cleaning Open the motor cover and clean this area for the basic cleaning additionally to the above listed work chapter D 2 1 5 The pollution of the door by cleaning the environment should be avoided The order of the cleaning steps and the art of cleaning can avoid that a purified door is contaminated again by cleaning the periphery If the door is again contaminated by cleaning the periphery it must be once again be cleaned in the appropriate places inside Periods need to be adjusted according to the cleaning respectively HACCP concept and production relevance 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 40 ASSA ABLOY D 2 1 Cleaning recommendations for special areas D 2 1 1 Cleaing control cabinet i e t may get no splash water in the control cabinet XT e Do not use a water hose or pressure washer e Even when main switch is turned off components within the control cabinet can be electrically live 1 Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection 2 Open the control cabinet door to clean the drainage channel on the control cabinet and the rubber seal in the con
14. Operating Instructions ASSA ABLO Y Albany High Performance Doors 6410R0231 ASSA ABLOY 2012 ASSA ABLOY Entrance Systems AB All rights to the door and the related operating instructions are protected Legal action will be taken in case of imitation or copying of the door system These operating instructions may not be reprinted or otherwise reproduced without the written consent of ASSA ABLOY Entrance Systems The general terms and conditions of ASSA ABLOY Entrance Systems AB are applicable ASSA ABLOY Entrance Systems reserves the right to make technical changes These operating instructions are an integral part of the door The original version of the operating instructions is in German Manufacturer ASSA ABLOY Entrance Systems AB Lodjursgatan 10 SE 261 44 Landskrona Sweden Internet www albanydoors com Email verkauf de aloany assaabloy com 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 2 Contents 1 InfrodU6HOTD oer ern exa bebe cea db d EC EVA EE E EE DE EE Lau 5 1 1 Applicable GOCUM SHES oc uarie S rir en oerte rr ete d 5 1 2 Declaratio oft GOhfOEHTIlly sos cocer met qoe ec e xe LE qe tu uode veu Rea Uri TRAE 5 1 3 Amendments and validity ssesesseessesesssseseseseeeeeeeeene nennen nnne 5 1 4 Document slorages iis cedex iia cux ila Cua xb lax bau AA 5 1 5 arger OLIO e tr 5 1 6 CO VelllioDiS cisco Chahta cita Ca CA Lacan ha CR e 5 1 6 1 M RUMEN aio eot os
15. ally open or close by itself 2 If necessary open the door further by manually pushing it upwards Inthe case of roll doors the door curtain will wind onto the top roll when you do this 3 In order to reach regular function of the door again the emergency lever must be put into its original position again 4 To use doors with ACS50 regular again the power to the control must be turned off and on again main switch or mains plug For doors with MCC follow instructions on display Once a reference search has finished the door is ready for use again Power on brake Standard for RR300 Plus F R option for RR300 Plus Switching off the main switch or unplugging the power cable causes automatic door motion If the door is closed it opens partially and if it is open it closes partially The RR300 Plus R R automatically opens by at least 2 m due to the spring driven counterbalance It is not possible to operate the door with an emergency lever i The door is not designed for a regular manual operation 2 5 2 4 Uninterruptible power supply UPS Doors with frequency converter control only MCC can optionally be equipped with an uninterruptible power supply UPS In case of a power grid failure the door can be run several times immediately after the failure Alternativly one time up to 4 hours with the UPS in idle mode Precondition the batteries have to provide the specified capacitiy WARNING Risk of electrical sh
16. bricating oil on the floor tools and other material should be removed from the floor when work has been finished Inspection plan Record all maintenance repairs and modifications in the inspection list included in the inspection book for every door to ensure that all changes can be traced The necessary service events inspections and implementation notes are documented in the inspection plan in chapter B WARNING Risk of personal injury and material damage RR300 Plus F R The function for exit and escape routes is not ensured if maintenance plan is not followed c Compliance with the inspection plan is necessary in order to maintain the exit and escape routes characteristics Special points of the inspection plan for the RR300 Plus F R have priority 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 23 ASSA ABLOY DANGER Risk of explosion RR450Ex 600Ex Improper maintenance nullifies the Declaration of Conformity with regard to the ATEX directive c Compliance with the inspection plan is necessary in order to maintain the explosion protection characteristics Maintenance activities and extended downtime periods if any should be planned in 6 2 3 Cleaning and care 6 2 3 1 Door curtain Pay particular attention to the cleaning instructions in the appendix for the RRClean C and RFood D 2 doors CAUTION Risk of material damage Improper cleaning of the curtain may cause damage to
17. ch off Check main switch switch on Stop circuit interrupted Check stop circuit Not used stop inputs must be bridged in accordance to the circuit diagram Door does not close Up impulse permanently activated Test impulse actuator Photocell interrupted disconnected Test safety devices Door close only with next impulse Toggle circuit adjusted Check adjusted control function 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 20 ASSA ABLOY Installation DANGER Risk of injury Improper handling of the packaged door can lead to injury c The palette must be placed on even ground gt Do not remove the pallet before the start of installation 5 1 5 2 Inspecting the delivery The door is mainly preassembled when delivered The side columns are fixed together with the barrel cover the motor cover if ordered fixing material and control unit onto the transport device wooden palette Check the door for damage during transport e Check the delivered items against the order documents to ensure that the delivery is complete Fitting preparations DANGER Risk of injury Incorrect installation of the door can lead to injury gt The door must only be installed by trained authorized personnel c The fitting should only be done by manufacturer personnel subcontractor or manufacturer trained personnel c Do not remove the straps securing the door curtain u
18. cting the operating personnel and for technical maintenance of the door These instructions for the basis for intended use and faultless functioning of the door The Albany RR300 Plus F R has been built to state of the art standards and the recognised safety guidelines for exit and escape routes and has been approved by an independent test body Any change whatsoever to the door results in withdrawal of the operating permit as an emergency exit door the manufacturer s liability is cancelled by any failure to observe this requirement or in case of deliberate misuse The door system may be disconnected from the mains in emergencies only Disconnecting it over night is not allowed General information The Albany RR300 Plus F R conforms to the essential requirements of the Richtlinie ber automatische Schiebet ren in Rettungswegen AutSchR Guidelines for Automatic Sliding Doors in Escape Routes The consent of the responsible building authority must always be obtained for approval for use of the door in exit and escape routes The door has an automatic opening function to make it suitable for use in exit and escape routes This ensures opening of the door as soon as persons move towards the door in the exit direction The door has various monitoring and control devices to ensure the exit function even in the event of a power failure or damage spring wear spring break belt break The exit and escape route function exists if the ope
19. e control unit used See the control unit user manual for a description of the control unit concerned 4 1 Safety e Do not use this door for purposes it is not intended for e Upon damage of the door mechanical or electrical it must immediately be set off operation This is especially valid on damages of the power net or control cables e Use only equipment or additional features which are authorized by the manufacturer of the door e Observe the safety instructions in Section 2 also 4 2 Operation The door has an electrical drive unit and can be operated using the buttons on the door control unit or by additional external actuators and safety devices The Open Stop and Close buttons on the door control unit should normally be used during door setup maintenance and repair activities In regular operation the door is controlled by external signal sources such as pull cord switches induction loops radar or radio detectors or mushroom head buttons connected to the door control unit via dry contacts 4 3 Malfunction DANGER A Risk of personal injury and material damage Improper troubleshooting can lead to damage to the product and serious personal injuries gt Troubleshooting must always be performed by suitably qualified staff c Switch off power to the door and secure it against accidental re activation Also observe the instructions in Section 2 5 2 4 Uninterruptible power supply UPS c Secure the main s
20. e figure shows the Albany RR300 and Albany RP 2000 doors Other types of door may differ in detail Doors with flexible curtains Doors with rigid curtains 1 5 5 4 4 8 d 9 E 9 1 Photocell light curtain Drive system 2 Door curtain Electric control box 3 top roll side frame Option Top roll cover Aluminum 4 anodized steel galvanized stainless steel Continuous safeguarding electrical safety edge rubber profile Option Motor cover Plastic stainless steel steel powder coated aluminium 6410R0231 UM Content RapidRoll ENO4 docx The door line photocell or light curtain 1 safeguards the closing area of the door Disruption of the beam prevents or stops the closing movement and the direction of travel is reversed Depending on the type flexible door curtains 2 are made from coated dyed and woven polyester monofilament or from transparent or coloured PVC with draught strips Rigid curtains are made from aluminium slats 30 06 2014 14 3 2 3 2 1 ASSA ABLOY The top roll 3 has a tubular aluminium shaft with glued in shaft stubs or a steel shaft Doors with rigid curtains have a special DiscDrive system that prevents direct contact with the curtain surfaces during roll up The drive unit 6 contains an electric motor gearbox and limit switches The electrical switchbox 7 contains an ACS25 ACS50 MCS or MCC contr
21. e ur EE PR BLU RR M ME D E UI EE 6 1 6 2 o circulo CO EDE 6 2 Safe 7 2 1 General safety advige oos stre ne ato andre ni net nt Mec Hacc 7 2 2 Personal protection uiri eei ae prope tracto E REEL pa EMO SE EE E ELE bas UMS SEP pne reduc 7 2 3 Duty of care by the operator oco ooo eo E EU Td EE qe du Ed 8 2 4 MPA RN 1S Ct a gs nc c O 8 2 5 Safety devices P O 9 2 5 1 Electric safety DeVIG BSc cuan bea o qc pem Dome nays son pete 9 2 5 2 Additional protection SyStelris decedunt eoe t edd m hue de duet 9 2 6 Safety devices Tor RR300 Plus EB unie etian Rea pnta utet dias 11 2 6 1 Radar motion delGclof uei ep inre edendo eese de dc tup UE ape nudes 11 2 6 2 Belt and spririg break SWIG Jes nuire diiit et Ev LER en re nix ta ve RO ERU aiaiai 11 2 6 3 Catching device with Solenoid actuators sseeenne 12 2 6 4 Regular self tests of the door 0 cceeeeeeeececceeeeeeeeeeeeeeeaeeeeeeeeeeeeeenenaaaeaeeeeeeeeeeneee 12 2 6 5 Escape route deactivation switch optional eceeceeeneeeeeeeeeeeeeeeeeeeeeeeeeeeeeteeee 13 2 7 Resid altiSkS acre peto PEN eive 13 3 Door Product Description rera reern reni naci ee Dini 14 3 1 Door Components o 2 sender uid teet gotta teet ette nios potete p e pe tibiae GS ste Eid peace 14 3 2 Operation and installation of the door systems ceeeeeeeeeee
22. echanical damage and that they function properly required 4 detection range whole door width up to 1 5m in front of the door Check main closing edge according to EN 13241 1 alalalalalalalalalalala respectively local standards 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 37 ASSA ABLOY Appendix Cleaning reference RRClean The door could be cleaned with commercially available cleaning agents and disinfectant for clean room applications CAUTION Risk of material damage Improper cleaning of the door may cause corrosion and discoloration of the surface c Do not use chlorous cleaning agents and disinfectant CAUTION Risk of injury Door movements during cleaning could cause injuries c Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection The maintenance inspection work and basic cleaning must only be performed by manufacturer trained authorized personnel Always follow the safety instructions mentioned in the user manual Maintenance cleaning Clean outer surfaces with cleaning agent and disinfectant Basic cleaning during inspection Open side frames and clean side frame guides and trailing chain for cable Clean lintel profile Open top roll and motor cover and clean this area Mount everything in reverse order Periods need to be adjusted according
23. eeeeeeeeeeeeeeeeneeeeeeeees 15 3 2 1 Safety Systems c uiuere pied retu t tuo ue E Ebr tates ious pose st Hiusesd o seneed poses oasuens UE eneess 15 3 2 2 Slats only doors with rigid CUrtaiNS eeeeeeeeeeeeee eee eeeeeeeeeeeaeeeeeeeeeeeteseeenaeeeeeeess 16 3 3 Emergency exit door Albany RR300 plus F R cccccccccccccccccceccceceeeeeeeeeeeeeeess 17 3 3 1 Conditions Of USG ccr Ete es ce reete Mbps MIN 17 3 3 2 General MONMAUOM ioi erba et erect aec ecole Cr tA Cet iu UE 17 3 4 ONO EET RUE MM 17 3 5 Drive ci oom RO DRE LU RD EDD anata las 18 3 6 Identification plate POR PRRRONTRNRTRTPORTRPPRO REPRE 18 3 7 Technical Dig deett ct LM A c M ME E LL EU 18 4 Operati M e 19 4 1 Sale coute Le Li ALL LL Mi dE RE Coe ere M A A A E 19 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 3 4 2 4 3 4 3 1 4 3 2 5 1 5 2 5 3 5 4 6 1 6 2 6 2 1 6 2 2 6 2 3 6 3 6 4 6 4 1 6 4 2 6 5 A 1 A 2 A 3 B 1 B 2 B 3 D 1 D 2 D 2 1 D 2 2 E1 E 1 1 E2 ODGFalOi ui o debe rosae dab dra qure ted date tc d de tee a a dM aai ada 19 Wie MUMGHON EE EE o 19 Mechanical malf ncltlos 3 a bh a e dee d te c De tea di e ep dest 20 EJectriGal Taulis 2 ie E tuam node e P e n none DAD ue 20 Installation 21 Inspecting the dellVel Wes ec ct sd eI uU E E 21 Fitting preparations 35 audet abet rato oubli her neu te er
24. f about 1m D 2 1 3 Cleaning inside top roll cover 2 Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection CAUTION Risk of personal injury and material damage Door movements during cleaning could cause injuries or material damage Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection 3 Open top roll cover Loosen both screws at the front side of the top roll cover Do not remove the screws from the top roll cover Pull the top roll cover forward This swings the top roll cover forward and upward and remains open in the topmost position e Use a water hose for cleaning e Do not use high pressure cleaning machine 4 Check cleanliness inside the top roll cover and clean if required 5 Check cleanliness of the cable channel which connects the side frames and the gap between cable channel and wall and clean if required A clean soft brush with plastic bristles can be used to support the cleaning 6 Close the top roll cover and secure with the lock screw 7 Switch on main power 8 Carry out test run D 2 1 4 Cleaning the rope for the counterweight system option 1 Open the door completely 2 Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug
25. fault This is indicated by an error message on the display This error message can be acknowledged and the door can 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 12 ASSA ABLOY be released by input of a code by an authorised person The self tests are then repeated If these tests are successful the door is ready for use again The allowable time interval of 10s for performance of the tests on the electronic functions is controlled by a timer relay This relay is located in the control housing and works with dropout OFF delay CAUTION Risk of personal injury and material damage The door stays open if the self test is not successful after repeated executions c The door must be inspected by a service technician 2 6 5 Escape route deactivation switch optional If the function of the radar motion detector the checking of the belt and spring break switches and the regular self tests is to be suppressed e g at the weekend or during company holidays the exit and escape route functions must be deactivated by an authorised person using a key switch with the door closed This person is responsible for ensuring that the exit and escape route functions are activated if the building is being used by people again i e is occupied A display at the operator unit of the MCC control provides information about the condition of the exit and escape route deactivation In the event of a power failure the door opens automaticall
26. formation included in the other sections e Use the door only for the intended purpose Upon transfer of this door to third parties this user manual must also be transferred to this party Personal protection e No special personal protection equipment is required for using the door Nevertheless the door may only be used by trained and authorised staff Furthermore the regulations of the plant or facility where the door is used also apply e The use of the emergency lever if existent may lead to a partly self opening or closing of the door e Upon failure of the electrical drive the door leaf may be unlocked and moved upwards by use of the emergency lever At doors with emergency hand crank the door can be opened and closed by turning the emergency hand crank which must be inserted on the bottom of the motor This is also possible for doors with manual hand chain In this case the drive is switched powerless WARNING The door may partially open or close by itself after the emergency manual lever has been activated There is the risk of injuries by the movement of the door curtain c Observe the door during use of the emergency manual lever permanently WARNING Risk of injury It can lead to injuries by simultaneous starting of the motor during inserting the emergency hand crank c Always switch off the main switch before using the emergency hand crank e Do not put your hands on the side columns of the door o
27. hafts and flange bearings 1 Lubricate pedestal bearing and retighten it s fixation Check the drive shaft in the aluminium shaft for secure fit Check tight position of belt and rope discs Check the condition of the cable drums Check retainer of spiral disk on the shaft Chain drive check fastening of locking element tighten the screws with 18 Nm Check condition of sound isolation profiles at the spiral disks Check flat belts for wear and damage check connection to spiral disks Door curtain shavings in the guides Check curtain for cracks and traces of scrapes or bottom profile Check fixation of door leaf at the top roll and at the Check tight position and wear amp tear of the wind tabs 1 replace teeth Bead belt condition lubrication wear if necessary Check exact position of slat sealing Co N Co Check fixing of slats on pulling device and endcaps 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 35 ASSA ABLOY Inspection RR300 RR200 RR300 Plus RRClean RFood RR355 RR392 RR450 RR500 RR600 Check slats around adapters for damage especially 1 5 from top Check solid position of slat adapter coc RR3000 R GL wmm RHR3000 XXL c RR38000 ISO Bottom profile Check tight fit and condition of profile guiding pieces and the gliding pieces Check condition of
28. hain drive optional BE kenalpanve Mains power See control unit manual See control unit manual Motor performance 1 1 kW 1 1 kW Control unit MCC ACS50 50 Hz only MCC ACS50 50 Hz only Control voltage 24 V DC 24 V DC Operating temperature range 10 C 40 C 10 C 40 C Motor protection IP55 IP55 Side frame anodized aluminum galvanized steel Door curtain PVC Rolltex PVC Rolltex Lifting device Pulley and cable Pulley and cable Sound pressure level 70 dB A 70 dB A 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 30 ASSA ABLOY Albany RR450 Albany RR600 Door principle Roll door Roll door Running direction vertical vertical Application Exterior and interior door Exterior and interior door Wind class 2 3 Available sizes W min 2000 mm 1500 mm W max 7500 mm 6000 mm H min 2000 mm 2000 mm H max 6000 mm 6000 mm Drive Electrical chain drive optional electrical Mains power See control unit manual See control unit manual 1 1 kW Motor performance 1 5 kW explosion proof doors ERW Control unit MCC ACS50 50 Hz only MCC Control voltage 24 V DC 24 V DC Operating temperature range 10 C 40 C 10 C 40 C Motor protection IP55 IP55 Side frame anodized aluminum anodized aluminum Door curtain PVC Rolltex RollTex Nomatex PVC Lifting device
29. he explosion proofness downtime at the time of external execution of the exchange which can be expected approx 8 10 working days Regular conditions central European climate door mounted interior or exterior with covers no aggressive ambient conditions 150 000 cycles 10 000 cycles gt 150 000 cycles 20 000 cycles B2 GMP relevant inspection only RRClean Could be done also by the customer Mechanical components proposal Check air leakage Curtain should permit only small air leakage around gaps 3 months or 25000 cycles Motor sealing Motor cover should fit firm and tight cable glands must be orderly 3 months or 25000 cycles 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 34 B 3 Inspection plan ASSA ABLOY Inspection RR300 RR200 RR300 Plus RRClean RFood RR355 RR392 RR450 RR500 RR600 RR3000 R GL RR3000 XXL RR3000 ISO Installation fixings Tighten screws no Co Check welding seams NIN w N Drive Check the fixing of the torque arm and buffer Check brake condition and function of break rele lever ase Check operation smoothness and function of the emergency manual lever maybe lubricate Check the chain adjust and possibly retension a lubricate nd RR450Ex 600Ex Change bearings in motor Drive shaft Check screws to drive s
30. ii fe iler i Tru d 21 Installation t scio ct ctc LI eM E M LM DM ACIE M EM E ME 22 DisinabhllifiQga suiit etri tne rbd eei pet rene etuer eee tris eps nnne eneee 22 Life CY Cle E A H CE a 23 juri iro TT 23 Maintenance and Cleahlhiq e dace eodd o D ee e taa Odd ecd ids 23 Safety iNStrUCtiONS cc ccceceeeeeeeseceecceeeeeeeeeeeeeaaeeeeeeeeeeeeesseaaaaeeeeeeeeeeeeeesesaaeeeeeeees 23 dorziers eene zio 23 CIS AMIN eA ares eae aed a Medline ne a a a a aaa tunel ie 24 Decormisstonifiqg esocas reete ette Nette NEeSES 25 Storage ana TANS DOU sss cce occid beet aed Eee i bed Um ue edu bcd ve sane 25 SETA DOU ssa ce URN PUN TOT OH la cine erate tagcat es 25 is fe m 26 IBIsrc E Cass tele tecsiediate 26 Appendix deme en trm 27 Technical Data Doors with flexible curtains eeeeeeeseeeeeeeee 27 Technical Data Doors with rigid curtains sssseeeeeneeeenee 32 Maximum opening and closing speeds eessssssssseeeeeeeeeenn 33 Appendix INS POCORN wi uicti aa tuiu eai EOFa eve pile Rus cuiu Uwe DUe ax ead COVa DUlvRVaE RR RUC DUE Cue SIR QUE 34 Service IMG WAS isch oet epo E tae M er So De M Lo tenue 34 GMP relevant inspection only RRClean ssseeeeemm 34 INSPOCTIOM DLA Mes Seti MP DE 35 Appendix Cleaning reference RRClean
31. nce Side frame covers RR200 No No screwed on RR300 No No None RR300 Plus optional Springs screwed on ei iine No No screwed on RFood No weights optional hinged RR355 Yes Springs screwed on RR392 Yes weights screwed on RR450 RR600 Yes Springs hinged RR3000 R GL Yes Springs screwed on RR30001SO XXL No Springs screwed on Safety systems All RapidRoll doors are fitted with standard compliant protection on the main closing edge In addition damage to the door in the event of a collision can largely be avoided by an optional breakaway mechanism 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 15 ASSA ABLOY The following systems are available Breakaway mechanism Manual Function After a collision the crash system can be manually repaired Self repairing by pressing a button The breakaway mechanism is restored to the operating position SRD Automatic breakaway mechanism minimises collision damage The safety systems fitted to the doors are listed in the following table Type RR200 RR300 RR300 Plus Securing the main closing edge electrical safety edge Breakaway mechanism Manual RR200 RR500 electrical safety edge Self repairing electrical safety edge or optional RRClean None pre running photocell RFood electrical safety edge or optional Kanval pre running photocell pre running photocell or optional T iss elect
32. ning height is at least 2m The door is delivered with a display on which information for operation and about the status of the door is displayed It is therefore recommended that this display be installed in the immediate vicinity of the door if the display is not planned to be mounted on the side frame Control unit Albany doors may be operated with a powerful frequency converter control unit MCC respectively MCS FC which enables soft acceleration and deceleration of the door Alternatively several types of doors can be operated with a contactor control unit ACS50 respectively MCS R See the table in the appendix Section A 3 for the maximum closing speeds of the individual door types DANGER Risk of electrical shock Operating doors with drive units or control units other than the recommended types may create a risk of electrical shock c The door must only be operated with an original drive and control unit from the manufacturer 6410R0231 UM Content RapidRoll ENO04 docx 30 06 2014 17 3 5 Drive ASSA ABLOY The high speed doors are operated by electrical drives The drive unit is installed at the upper part of the door vibration muffled and not accessible from the floor The position of the drive unit may be selected by the customer for the right or left hand side The temperature of the drive unit is safeguarded by a thermo element which disrupts the power supply of the drive upon overheating In the case of door
33. nnectors and avoid kinking cables Store all components in a clean dry place 6 4 Storage and transport 6 4 4 Transport The single door components must only be removed from the packaging at the site of installation DANGER Risk of injury Improper transport may cause the load to slip and fall c Observe the legal safety regulations when transporting the door to the fitting site The door must be secured against tilting or slipping c Lift the door at its centre of gravity to prevent it from tipping sideways 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 25 6 4 1 1 Dimensions of the door with packaging ASSA ABLOY Transport pallet Drive and control unit mm pallet mm x mm Door Length Width Length x width RR200 W 1000 530 800 x 600 RR300 RR300 Plus RRClean H 500 1500 800 x 600 RR355 RFood H 500 1650 800 x 600 RR392 H 800 1750 800 x 600 RR450 RR600 H 800 1750 800 x 600 RR500 W 1000 750 800 x 600 RR3000 R GL pallet 1 top roll W 850 750 inem w 660 en RR3000 ISO H gt 4700 pallet 1 top roll W 850 980 ee R GL ISO XXL pallet 2 side H 600 750 W width of door opening H height of door opening 6 4 1 2 Weight of the door with pallet Kg 10 Intermediate values can be interpolated weights may vary depending on specific configuration options RR300 RRClean N x N N x lt N o N oO S is tc pes
34. ntil after the drive unit has been fitted Complete the following preparations before installing the door e Check the fitting site with regard to necessary fixing points and lift up conditions If necessary a supporting frame or other fixing possibilities must be made The upper fixing points should be screwed onto a steel supporting frame or concrete element Consult the installation drawing in the inspection book e Check measures of the actual dimensions width and height of the door opening and compare with order papers e The fitting site must be secured against pedestrian and vehicle traffic e The plastic packing of the door must be removed before fitting e For the door RFood take note of chapter D 6410R0231 UM Content RapidRoll ENO04 docx 30 06 2014 21 ASSA ABLOY DANGER Risk of injury Unsecured guiding cover can fall down for door types RR3000 By pushing up and unhook the bottom guiding cover the upper side cover can be unmounted c The door must only be installed by trained authorized personnel c The fitting should only be done by manufacturer personnel subcontractor or manufacturer trained personnel c The upper side cover must be mounted when removing the bottom guiding cover 5 3 Installation The fitting team has a detailed installation manual In case of questions contact ASSA ABLOY Entrance Systems The door must be connected to the potential equalisation rail min 6 mm J
35. ock Voltage is still present on the door after mains power has been switched off c Switch off the power switch of the UPS as well c For working inside the UPS the internal switch must be switched off observe the operating instructions for the UPS 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 10 ASSA ABLOY WARNING Risk of personal injury and material damage Unintentional door motion can lead to damage to the product or severe personal injury c Switch off the power switch of the UPS as well c For working inside the UPS the internal switch must be switched off observe the operating instructions for the UPS 2 6 2 6 1 Safety devices for RR300 Plus F R Radar motion detector The door has a direction detecting radar motion detector with approval for exit and escape routes As a result the door opens automatically if persons move towards the door in the exit direction The exit direction is defined by the installation of the radar motion detector If the control detects a fault in the radar motion detector the door opens automatically and remains open It can only be put back into service after it has been repaired by a service technician The radar sensor must be set so that it covers the full door width and at least detects persons who are 1 5 m in front of the door Please refer to the installation instructions of the radar motion detector manufacturer for details of how to set and adjust the de
36. ol unit depending on the configuration The side frames 8 are made from galvanised steel aluminium or stainless steel and may also contain a counterbalance system depending on the door model Upon touching the safety edge 9 the door reverses into the open position immediately A pre running photocell may be used as an alternative Operation and installation of the door systems Albany doors are vertically opening high speed roll up doors They consist of two side frames a top roll with an electric drive unit a door curtain and a bottom profile The side frames guide the bottom profile and the door curtain which is rolled onto the top roll when the door opens During closing of the door the curtain rolls down from the top roll and is being pulled down by the self weight of the bottom profile and the door curtain In the case of doors with built in curtain tensioning the door curtain is also actively tensioned by the force of the curtain tensioning system Doors with a counterbalance system have this system housed in the side frames The counterbalance assists the drive unit during door opening and also enables manual opening for example in case of power failure by causing the door to open partially on its own The doors in the Albany RR450 series also have optional travelling wind bars which can be fitted either on the front or the rear of the door as necessary Type Curtain tension Counterbala
37. performed all safety relevant electrical and mechanical functions are checked During the performance of the self tests the exit and escape route functions are deactivated The electrical functions check is performed on the additional protective circuit the control inputs the radar motion detector and the spring and belt break switches Further the solenoid actuator is also actuated see Chap 2 6 3 The check of the mechanical functions concerns the self opening height This describes the achievable opening height by means of the spring mechanism without help of the motor e g in the event of a power failure The required self opening height is checked by releasing the brake and is 2m for use of the door in exit and escape routes This opening height must be reached within 5s time The self tests are first performed with the door closed The start of the self test is indicated at the display The electrical additional functions are checked within the first 10s after starting the self test Then the brake is released and the door is opened by the spring mechanism self opening If the opening height required for use in exit and escape routes is reached within 5s the door stops stops briefly and then opens up to the top limit position Following subsequent closing of the door the self test is completed If an error is found during the checking of the electronic or mechanical functions the door moves to the top limit position and switches to
38. pplicable in addition to the general operating instructions is provided for the uninterruptible power supply UPS Declaration of conformity The declaration of conformity document is enclosed in the log book which is delivered with the door Modifications that affect the technical data specified in the operating instructions or proper use i e modifications that materially alter the machine invalidate the manufacturer s declaration of conformity Amendments and validity The information contained in these instructions constitutes the technical specifications applicable at time of publication Significant changes will be incorporated in a new edition of the operating instructions The document and version number of these instructions can be found in the footer Document storage Keep these operating instructions in the storage bag inside the switchbox or for doors with an MCC control unit in the supplied document box Target group These operating instructions are intended for trained qualified and authorised staff All configuration activities and in particular repairs and maintenance may only be performed by employees of the manufacturer or other trained specialists Conventions This section explains the conventions used in these instructions for safety information and operations 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 5 ASSA ABLOY 1 6 1 Warnings Warning notices give advice of existing danger for life
39. r in the area of the top roll during operation e Lingering of persons in the working area of the door should be avoided For pedestrian traffic existing wicket doors should be used e Go upright with normal walking speed e Untidiness may cause accidents Keep the immediate area of the door tidy e Do not climb up the door Do not put up a ladder against the curtain 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 7 ASSA ABLOY e When performing any type of work on the door set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection Also observe the instructions in Section 2 5 2 4 Uninterruptible power supply UPS e Stop using the door immediately in the event of mechanical or electrical damage especially if the power cable or control cables are damaged e The door must only be operated on defined voltage or net frequency e Use only equipment or additional features which are authorized by the manufacturer of the door e Do not operate the door when excessive wind load is present i Wind class specifications always refer to the closed position of the door 2 3 Duty of care by the operator The door has been designed and manufactured under consideration of a risk analysis according careful selection of valid norms and further technical specifications The system meets status of technique and ensures the highest le
40. radar motion detector is 4000mm Note the opening height of the door The solenoid actuator is installed in the factory in the side frame on the drive side When installing the bottom profile the bended sheet metal plate must be mounted on the drive side as shown in Figure 1 and Figure 2 The metal plate is screwed onto the H section Sheet metal plate H section Figure 1 Display of drive side right hand side Figure 2 Hang the main spring in the spring mounting at the bottom in the side frame The S hook must then be hung in the spring and the eyelet of the monitoring switch see Figure 3 To do this the fixing nuts and screws of the monitoring switch must be undone Figure 3 Figure 4 www albanydoors com 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 46
41. rical safety edge SEIL tepainng RR392 electrical safety edge Manual RR450 pre running photocell or optional Self repairing electrical safety edge pre running photocell or optional SRD or Self repairing RR600 electrical safety edge RR3000 R GL pre running photocell or optional None XXL electrical safety edge RR3000 ISO Light curtain up to 2 5m height None The type of breakaway mechanism depends on the type of bottom edge protection All doors also have a door line photocell system integrated in the side frames Disruption of the door line photocell or triggering the safety edge leads to a complete stop of the door curtain After the door curtain stops it will reverse to the open position 3 2 2 Slats only doors with rigid curtains The slats are individually suspended double walled extrusions sealed relative to each other Type Slats Window s RR3000 R XXL Double wall anodised optional RR3000 GL Window frames anodised with single glazing Full RR3000 ISO foamed sandwich panel with steel sheets RAL optional 9006 The number depends on the door size and type among other things 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 16 3 3 3 3 1 3 3 2 3 4 ASSA ABLOY Emergency exit door Albany RR300 plus F R Conditions of Use These instructions are directed at the owner operator of the Albany RR300 Plus F R emergency exit door The owner operator is responsible for correct use instru
42. rol unit manual Motor performance 0 37 kW 0 56 kW 0 75 kW 0 75 kW Control unit MCC ACS50 50 Hz only ACS25 50 Hz only MCC ACS50 50 Hz only W max 4000 mm H max 4200 mm Control voltage 24 V DC 24 V DC Operating temperature 10 C 40 C 10 C 40 C range Motor protection IP55 IP54 with ACS25 IP55 Side frame Galvanised steel or stainless steel Aluminum or stainless steel Door curtain PVC Rolltex Nomatex Travitop PVC Rolltex Nomatex Travitop Lifting device Pulley cable and belt Sound pressure level 70dBA 70 dB A 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 27 ASSA ABLOY Albany RRClean Albany RFood Door principle Roll door Roll door Running direction vertical vertical Application Interior door Interior door Wind class 0 1 Available sizes W min 1000 mm 1000 mm W max 3500 mm 4000 mm H min 1000 mm 1000 mm H max 3500 mm 4000 mm H max ACS50 3500 mm Drive electrical electrical Mains power See control unit manual See control unit manual Motor performance 0 75 kW 0 75 kW Control unit MCC ACS50 50 Hz only MCC ACS50 50 Hz only Control voltage 24 V DC 24 V DC Operating temperature range 10 C 40 C 0 C 40 C Motor protection IP55 IP55 Galvanised steel or stainless Side frame s
43. s without counterbalance the gearbox is equipped with a catching device 3 6 Identification plate ALBANY ASSA ABLOY ASSA ABLOY Entrance Systems AB Lodjursgatan 10 SE 261 44 Landskrona Sweden Werk 301 Web www albanydoors com Mail info ads de albint com Kraftbet tigtes Tor EN 13241 1 Tortyp RR300 Auftragsnummer 0030047651 Serien Nr 000000001200000494 Jahr 20100817 22651 30047651 040 Schaltplan Nr Steuerung Typ ACS 50 Spannung 400 V 3 Phase Frequenz 50 Hz Max Leistung 3 KVA Schutzklasse IP 55 Temp Bereich 0 C 40 C Widerstand gegen Windlast 1 Wasserdichtheit 0 Luftdurchl ssigkeit 0 W rmewiderstand 0 f Made in Germany 89 106 EC 2004 108 EC 2006 42 EC ASSA ABLOY Entrance Systems AB DIN 4102 1 H the actual data will vary depending on the specific door 3 7 Technical Data The inspection book contains the following technical data Technical Data Door dimensions Location Dimensions of the installed door Principle drawing Fitting clearances Fixing points Fixing plan See the appendix Sections A 1 and A 2 for all other technical data for the door ASSA ABLOY Entrance Systems reserves the right to make changes to technical bd information listed in this document 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 18 ASSA ABLOY 4 Operation This section describes the operation of the door irrespective of th
44. t K Alkaline spot Sprinter Power T cleaning Sprinter Grease T Alkaline Apesin Combi DR T disinfectant Blutoxol K Alkaline disinfectant Apesin Combi DR T Acidly disinieciani Apesin KDR Food T Acidly disinfectant Apesin KDR Food T The security council impacts and application reference on the bundles the product information as well as the safety data sheet are to be considered 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 44 ASSA ABLOY E Appendix RR300 Plus F R E1 Radar motion detector RR300 Plus F R The best possible radar sensor settings are determined for various door heights and widths for simple putting into service of the radar sensor and for ensuring its function Despite the given reference values the function of the radar should be checked again 1 on site as the radar field depends on various parameters and may therefore perform differently on site required detection range whole door width up to 1 5m in front of the door Note and follow the operating instructions of the radar manufacturer E 1 1 Reference settings Installati Field Relay sup Filter ied ee geometry Hold function BMD field P 0 90 o Pl E48 time F E a Pize F 7 cle 6 downwards Direction detection width 2 2 2 2 2 2 2 2 2 2 2 2 2 2
45. tector Reference values are in a table in chapter E 1 1 WARNING Risk of personal injury and material damage The function for exit and escape routes is not ensured if more than one radar sensor is installed Connection in series of additional radar sensors is not allowed WARNING Risk of personal injury and material damage Unintentional door motion can lead to damage to the product or severe personal injury The function of the radar motion detector is not deactivated by the Stop button and continues to have priority The door is opened if a person is detected by the radar sensor regardless of whether the Stop button is pressed or not c The door must therefore be disconnected from the power supply before any maintenance and or installation work is carried out 2 6 2 Belt and spring break switch Proper function of the counterbalance springs and belts is monitored by switches which are located in both side frames In faultless condition the springs belts and switches are tensioned 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 11 2 6 3 2 6 4 ASSA ABLOY If a spring or belt fails the switch is released The door then opens electrically and switches to fault It can only be put back into service after it has been repaired by a service technician The switches are to be installed by means of hanging them in the S hooks in the hooks of the springs and fixing them to the spring mounting Chapter E
46. teel stainless steel Door curtain PVC PVC Travitop Lifting device Pulley and cable Sound pressure level 70dBA 70 dB A 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 28 ASSA ABLOY Albany RR200 Albany RR500 Door principle Roll door Roll door Running direction vertical vertical Application Interior door Exterior and interior door Wind class 1 3 4 if DW 6000 Available sizes W min 1000 mm 1500 mm W max 4000 mm 8000 mm H min 1000 mm 2200 mm H max 4000 mm 5500 mm Drive electrical electrical Mains power See control unit manual See control unit manual Motor performance 0 75 kW 0 75 kW Control unit MCS MCS Control voltage 24 V DC 24 V DC Operating temperature range 10 C 40 C 10 C 40 C Motor protection IP54 IP54 Side frame anodized aluminum anodized aluminum Door curtain PVC Rolltex plus Lifting device belt Sound pressure level 70 dB A 70 dB A 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 29 ASSA ABLOY Albany RR355 Albany RR392 Door principle Roll door Roll door Running direction vertical vertical Application Exterior and interior door Exterior and interior door Wind class 2 2 Available sizes W min 1000 mm 2000 mm W max 4000 mm 6000 mm H min 1500 mm 2000 mm H max 4200 mm 6000 mm Drive Electrical c
47. temperature positive or negative pressure or other special ambient conditions 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 8 2 5 2 5 1 ASSA ABLOY The door is defined for the closing of door openings especially on industrial buildings which are planned mostly for vehicle traffic of various types Exterior doors are resistant to wind and rain loads Exterior doors can of course also be used as interior doors For the door RFood take note of appendix D Safety devices Electric safety devices As electrical safety system a pre running safety photocell electrical safety edge or a light curtain in the door line can be used which are complemented by a door line photocell in the side frame All electrical safety systems are designed according to the product standard EN 13241 1 Before each closing movement of the door an internal test of the safety system and the door line photocell is being performed If a fault is detected the closing movement is disabled and an error message is displayed by the control system Doors in combination with MCC fulfill according to EN 13849 1 for the safety systems category 2 with performance level d and the emergency stop category 3 with performance level d Doors in combination with ACS50 or MCS fulfill the safety systems category 2 with performance level c and the emergency stop category 1 with performance level c With the ACS25 there is no internal test of the photocell before each down
48. the safety edge and the cable Check condition of the coily cable Check the condition and function of the crash system Check condition and function of wireless safety edge change battery if necessary side frame Check fixing and condition of the profiles with attachments Check cable laying and if applicable cable chain Remove dirt from the photocell optics Check condition fixing and lengthwise extension of the ropes and belts oO oj CO m JAIN N m AJ CO Check the condition and function of the counterweight system Check condition and installation of the springs and the spring mounting if applicable check for easy movement of the axial bearing Doors with ripped belt rope or broken springs are to be immediately taken out of service Yes Yes Yes Yes Yes Yes Yes Check leaf tensioning system 1 1 Check for wear amp tear s on guiding rails especially in the area of funnel s lt 4mm Renew belt s 15 16 16 Renew spring s 10 13 15 16 16 Renew ropes 10 11 Renew ropes and pulleys for counterbalance 11 12 14 Renew ropes or rubber cable for curtain tension 8 8 Renew flat belt 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 36 ASSA ABLOY EN S oM
49. the surface c Do notuse any glass cleansing liquids aggressive contents c Never use score cleansers scrapers razor blades and spatula etc c Clean with warm water small dose of mild plastic cleanser and a soft non bobble cloth DANGER Risk of personal injury and material damage Pollution of the curtain can cause reduction loss of the protection property for laser protection doors c The surface facing to the laser must be kept clean 6 2 3 2 Side Frames CAUTION Risk of material damage Improper cleaning of the door frame may cause damage to the surface c Do not use high pressure cleaning machine c Dust may be removed with a soft cloth c Harder dirt may be removed with water and general liquid cleanser c Dirt of grease or oil on metal surface may be removed with solvent containing cleanser 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 24 ASSA ABLOY 6 2 3 3 Surroundings Especially after maintenance work the floor around the side columns may be dirty with lubricants etc Carefully clean these areas 6 3 Decommissioning Follow the installation instructions for dismantling Disconnect power from the door before dismantling In particular ensure that all springs are de tensioned Also observe the instructions in Section 2 5 2 4 Uninterruptible power supply UPS Check parts that are subject to wear and replace them if necessary before reassembly Check all co
50. to the cleaning concept and production relevance 6410R0231 UM Content RapidRoll EN04 docx 30 06 2014 38 D 1 D 2 ASSA ABLOY Appendix RFood Special notes for the RFood are summarised in this annex Notes for the application in the food industry The following notes are applicable to the installation and operation of RFood in food processing plants A good cleanability and integration according the hygiene examination DGUV 11206 in the operational HACCP Hazard Analysis and Critical Control Points concept is possible when observing the following points An evaluation and consideration for the respective operational requirements must be done individually e Door application only as interior door The rooms are according EU regulation 852 2004 appendix II e Install the control box and additional parts e g actuators with a tilt angle of 3 The distance of the control box should be min 50 mm 2 e Cables are fed into the control box from below through cable glands e Use open cable duct of stainless steel for wiring outside of the door Observe the cleanability behind cable ducts and at fixing points e Install the door on the warm side when there are different temperature levels Thereby the condensation is prevented or reduced e Only packaged food or food in covered containers should be moved through the door e Use hexagon head screws for fixing the door the control box and additional parts e Seal the door to the
51. trol panel door 3 Clean with a clean damp cloth 4 Immediately close to the control cabinet door after cleaning D 2 1 2 Cleaning side frame 1 Open the door up to a height of about 1m 2 Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection CAUTION Risk of personal injury and material damage Door movements during cleaning could cause injuries or material damage c Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection 3 Open side frame Loosen the lock screw which is located in about 1m height at the front of the side frame 1 turn Move the lock screw a few mm to the side Pull the locking lever and push upwards Then swing open the side frame cover e Use a water hose for cleaning e Do not use high pressure cleaning machine 4 Check cleanliness of side frames especially of the cable chain and clean if required A clean soft brush with plastic bristles can be used to support the cleaning After cleaning you need to check whether all links of the cable chain are engaged Close the side frame covers and secure with the lock screw Switch on main power oN OO Carry out test run 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 41 ASSA ABLOY 1 Open the door up to a height o
52. vel of safety But this safety standard can only be reached in practice if all necessary measures and precautions are observed It is the duty of the door operator to plan the respective measures and check it s performance Observe the following instructions on safe operation of the door e That installation initial operation inspection maintenance repair work and dismantling is made only by manufacturer personnel or manufacturer trained qualified personnel e That only sufficiently trained qualified and authorized personnel operates the door system e Use the machine only for its intended purpose e That the machine is operated only in perfectly functioning state and that the safety features are regularly checked for orderly operation e The operation manual in a readable condition at all times is kept at the site of the door system for further use if necessary e That the operating personnel is continuously trained with regard to working safety and operating instructions and especially the herein containing safety instructions e The advice assembled directly at the control box and the door must be noticed and kept in readable condition at all times 2 4 Intended use If not explicitly otherwise described our doors are developed and tested for regular conditions We would be pleased to advise you on the choice of suitable options for use under special conditions such as persistent exposure on one side of the door to high or low
53. wall Horizontal sealings need a radius of min 3 mm or a downgrade e The used additional materials screws cables cable ducts sealing compound etc must be suitable for the condition of use e The door should be equipped the easy accessible side covers and a motor and top roll cover Cleaning reference RFood CAUTION Risk of material damage Improper cleaning of the door may cause corrosion and discoloration of the surface gt Do not use chlorous cleaning agents and disinfectant The maintenance and inspection work must only be performed by manufacturer trained authorized personnel Daily routine and basic cleaning must only be performed by briefed personnel Always follow the safety instructions mentioned in the user manual 6410R0231_UM_Content_RapidRoll_EN04 docx 30 06 2014 39 ASSA ABLOY CAUTION Risk of personal injury and material damage Door movements during cleaning could cause injuries or material damage c Set the main switch power switch to Off or 0 or disconnect the CEE plug and secure the switch or plug against accidental re activation or reconnection The door can be treated with commercial cleaners and disinfectants for the foodstuffs industry Recommendations for cleaning agents are listed in D 2 2 Surface cleaning 1 Close the door completely 2 Clean outer surfaces with cleaning agent and disinfectant Daily routine maintenance cleaning 1 Close the door completely
54. witch or CEE connector against being switched on again by locking it or by having a second person present c Secure the action area of the door If the error cannot be repaired please contact the after market department of the supplier or manufacturer of the door 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 19 ASSA ABLOY 4 3 1 Mechanical malfunctions Malfunction Possible causes Necessary measures Brake at the drive defect Exchange the brake Door opens independently Brake wrongly adjusted Adjust the brake Counter balance is oversized Call after market Manual opening not possible Counter balance defective Exchange the counter balance devices Bowden cable hanging off or too loose Check correct position and tension of the bowden cable Brake blocking Call after market Drive without any function Power supply is off Connect the door to the power Electrical connections defective Check electrical connections Fuse has blown Replace fuse curtain unwraps inclined Door not correctly installed Call after market An object was rolled up Close the door and check for enclosed object 4 3 2 Electrical faults Malfunction Door without any function Possible causes Power supply is off Necessary measures Check power supply net fuse Control system fuse blown Check control unit and exchange the fuse Main swit
55. y and remains in the open position even when the power failure is corrected The door can therefore not be viewed as being burglary or theft protection if the exit and escape route functions are deactivated WARNING Risk of personal injury and material damage The function for exit and escape routes is not ensured if the escape route deactivation switch is used The door remains closed and it can then not be used either as a door or as an escape route c The exit and escape route functions must be activated if the building is being used by people again i e is occupied 2 7 Residual risks The door has been designed and manufactured under consideration of a risk analysis according careful selection of valid norms and further technical specifications The system meets status of technique and ensures the highest level of safety But this safety standard can only be reached in practice if all necessary measures and precautions are observed In particular when the door is used by people it must be ensured that they have been instructed in the use of the door and advised of the potential danger of walking under the door while it is closing 6410R0231 UM Content RapidRoll ENO4 docx 30 06 2014 13 ASSA ABLOY Door Product Description The operation and construction of the door are described below Consult the appropriate tables to determine the configuration options available for specific door types Door components Th