Home

Spec Sheet

image

Contents

1. Front Access Fuse Replacement part number Wickmann Wickmann 19343 1 6A or 19193 6 3A Wickmann 19181 4A 19193 6 3A Wickmann 19181 4A 5V 1769 Bus Overvoltage Yes Protection 24V 1769 Bus Overvoltage Yes Protection Isolation Voltage Input Power Verified by one of the following dielectric tests to 1769 Bus 1836V ac for 1s or 2596V 1200V ac for 1s or 1697V 1836V ac for 1s or 1200V ac for 1s or dc for 1s dc for 1s 2596V dc for 1s 1697V dc for 1s 265V Working Voltage 75V Working Voltage 265V Working Voltage 75V Working Voltage IEC Class 1 grounding required IEC Class 1 grounding required IEC Class 1 grounding required IEC Class 1 grounding required 1 Available in January 2001 2 Refer to the Temperature Derating graphs on pages 25 through 30 in the Compact Expansion Power Supplies Installation Instructions Specification Operating Temperature Expansion Cable Specifications 0 C to 60 C 32 F to 1 40 F Operating Humidity 5 to 95 non condensing Hazardous Environment Class Class Division 2 Hazardous Location Groups A B C D UL 1604 C UL under CSA C22 2 No 213 Publication 1769 TDO03A EN P November 2000 Communication Choices Publication 1769 TDO03A EN P November 2000 CompactLogix The CompactLogix5320 controller provides several communication options to fit into a variety of applications The buil
2. 19 2 to 31 2V de required 47 to 63 Hz 47 to 63 Hz Maximum Line Requirement 100 VA at 120V ac 50 VA at 24V de 200 VA at 120V ac 100 VA at 24V de 130 VA at 240V ac 240 VA at 240V ac Green Input Power Available ON 5 and 24V de current available from power supply Diagnostic LED OFF No input power Power fail enabled Overvoltage Exceeded Protection Enabled Maximum Inrush 25A at 132V ac 30A at 31 2V de 25A at 132V ac 30A 10Q source impedance 10Q source impedance 40A at 265V ac 40A at 265V ac 10Q source impedance 10Q source impedance Line Loss Ride Through 10 ms minimum to 10s maximum 5 ms minimum to 10s maximum Output Bus Current Capacity 2A at 5V de 2A at 5V de 4A at 5V de 4A at 5V de 0 C to 55 C 0 8A at 24V de 0 8A at 24V de 2A at 24V de 2A at 24V de Output Bus Current Capacity Refer to the Temperature Derating graphs on pages 25 through 30 in the Compact Expansion Power Supplies 55 C to 60 C Installation Instructions Minimum Load Current 0 mA at 5V de 0 mA at 24V de 24V de User Power Capacity 250 m2 NA 0 C to 55 C 24V de User Power Capacity 200 mal2 NA gt 55 C to 60 C 24V dc User Voltage Range 20 4V dc to 26 4V dc NA Short Circuit Protection Front Access Fuse Replacement part number Wickmann 19195 3 15A Front Access Fuse Replacement part number Wickmann Front Access Fuse Replacement part number Wickmann 19195 3 15A or
3. 256 color 800 x 600 minimum for optimal resolution CompactLogix Operator Interface Devices Electronic operator interface devices provide you with powerful plant floor control and data monitoring capabilities for improved productivity They are easy to use rugged and reliable Operator interface devices also save valuable panel space and are designed for easy modification as your process expands or changes The PanelView products listed below are only a partial offering of the Panel View Standard HMI Human Interface products For more information refer to the PanelView Standard Operator Interface Terminals System Overview publication 2711 SO001A US P PanelView Operator Interface Terminals The PanelView operator terminals offer electronic operator interface capabilities in a space saving flat panel design The result is a compact package that is loaded with performance functionality These terminals feature pixel graphics for enhanced operator screens The PanelView Standard 300 and 550 interfaces have monochrome LCD PanelView 300 Micro displays while the PanelView 600 has either an active matrix thin film transistor TFT or passive matrix color display PanelView 550 Touch Only Monochrome PanelView 600 Keypad Color Publication 1769 TDOO3A EN P November 2000 Controller Memory Estimation Publication 1769 TDO03A EN P November 2000 CompactLogix The following equations provide
4. AB Allen Bradley Technical Data CompactLogix5320 Catalog Number 1769 L20 Take advantage of the Logix control engine The CompactLogix5320 controller supports all the shared Logix functions and execution model CompactLogix as a member of the Logix family is part of a complete system level architecture Reduce program development and training costs CompactLogix uses the same RSLogix 5000 programming editor as the other Logix controllers So if you know how to program one of the Logix controllers you know how to program them all Utilize all the benefits of the Compact I O architecture The 5320 controller connects directly to existing Compact I O modules That means the CompactLogix system offers you modular rackless construction It also provides you with greater flexibility eases initial assembly and speeds module replacement Features and Benefits Table of Contents System Overview 3 Application e erae 5 Compact I O Modules sccseceeecee 6 Power Supplies and Cables 0 eseee 9 Communication ChoiceS 0 eceeeeeee 2 Programming Software 0 eceeseeeees 4 Operator Interface Devices 0eeeee 5 Processor Memory Estimation ccc0 6 DOCUMeNtatiOn cece J OpetificatiON Sennin 8 Mounting Dimensions ccccecceeeeseeteeees 9 Allen Bradley Support cccccccesceseeeeseene 20 Publication 1769 TDO03A EN P November 2000
5. 0 35 full scale at 25 C Output Error Over Full Temperature Range 0 to 60 C 32 to 140 F Voltage 0 8 Current 0 55 Open Short Circuit Overvoltage Protection Yes Output Overvoltage Protection Yes Channel Diagnostics Over or under range by bit reporting output wire broken or load resistance high by bit reporting current mode only 1 Includes offset gain non linearity and repeatability error terms Publication 1769 TDO03A EN P November 2000 CompactLogix 9 Power Supplies and Cables There are four 1769 power supply options e 1769 PA2 e 1769 PB2 e 1769 PA4 e 1769 PB4 Just double the width of a standard 1769 I O module these power supplies give you the ability to distribute bus system power to your compact I O modules from either side 1769 Power Supplies B e Upper and lower panel mounting tabs e Terminal identification diagrams e Barrier type terminal blocks provided e Finger safe covers e Front access replaceable fuse with cover e Provides maximum utilization of power supply output current capacity 1 Available in January 2001 Publication 1769 TDO03A EN P November 2000 Publication 1769 TDO03A EN P November 2000 CompactLogix 1769 Bus Expansion Cables e Allow you to expand the 1769 I O system beyond the limit of a single power supply e Provide for system configuration flexibility by allowing horizontal or vertical system expansion Communicat
6. CompactLogix By utilizing the Logix Control Engine CompactLogix supports the Logix Instruction set tasking model and data model Application programs created for other Logix controllers can be easily ported to the CompactLogix controller RSLogix 5000 provides a single programming environment for the Allen Bradley ControlLogix FlexLogix SoftLogix and CompactLogix controllers Results in reduced program development and training costs Built in RS 232 programming port supporting DF1 Full and Half Duplex protocols DH 485 protocol and ASCII support Provides for direct connection for programming operator interface devices and ASCII devices as well as dial in remote programming Allows for networking of up to 255 devices communications using modems such as radio modems or leased lines and remote programming monitoring Direct connection capability to DH 485 DeviceNet or Ethernet network interfaces By using the DH 485 communication interface CompactLogix can be connected to a DH 485 network of up to 32 devices for peer to peer messaging The DeviceNet communication interface provides a connection to a DeviceNet network of up to 64 devices with slave I O peer to peer messaging and programming capability upload download monitoring on line editing The Ethernet communication interface provides a connection to an Ethernet network for peer to peer messaging and programming capability upload download monitorin
7. an estimate of the memory needed for the 5320 controller Each of these numbers includes a rough estimate of the associated user programming Depending on the complexity of your application you might need more or less memory Controller tasks Digital 1 0 points Analog 1 0 points Motion axis 1 Only virtual axis available ___ 4000 __ 40 _ 2600 _ Total ____ bytes minimum 1 needed bytes ___ bytes _ 8000 _ bytes _ bytes NOTE As required by the application additional memory should be left unused for messaging and other communications operations For example this table list configurations for Location A and Location B Controller tasks Location A 1 continuous 1 periodic STI Location B 1 continuous Digital 1 0 points 10 18 22 9 5 64 24 15 21 13 5 78 Analog 1 0 points 3 2 5 3 2 3 8 The 5320 controller has 64K bytes of user memory available Estimate memory as shown below Controller tasks Location A bytes 2 x 4000 8 000 Location B bytes 1 x 4000 4000 Digital 1 0 points 64 x 400 25 600 78 x 400 31 200 Analog I 0 points 5 x 2600 13 000 8 X 2600 20 800 Total bytes 46 600 56 000 CompactLogix Documentation Related Documentation Additional user documentation presents information according to the tasks you perform and the programming environment you use Refe
8. frequency range may be 150 kHz to 30 Miz if the Radiated Immunity frequency range is 30 Mkz to 1000 MHz CompactLogix Mounting Dimensions CompactLogix Controller HH r A A I E Y NOTE All dimensions are in mm in lt p gt lt E Hole spacing tolerance 0 4 mm 0 016 in Dimension 1769 L20 Height A 118 mm 4 649 in Width B 50 mm 1 97 in Depth C 87 mm 3 43 in CompactLogix System 15 25 _ 35 35 35 35 28 5 590 985 1 38 1 38 1 38 1 38 1 12 132 jo jo 5 197 Blo 2 N O N O Q 12602 S z amp 5 a 6 4 826 0 0089 Ef co p oO a oO uw NOTE All dimensions are in mm in Hole spacing tolerance 0 4 mm 0 016 in Compact I 0 Expansion Power Supply and End Caps 40 35 35 35 28 5 1 58 1 38 1 38 1 38 1 12 J 132 5 197 122 6 0 2 4 826 0 008 Left End Cap Compact 1 0 Power Supply Compact 1 0 Right End Cap NOTE NOTE All dimensions are in mm in Hole spacing tolerance 0 4 mm 0 016 in Compact I O expansion cables have the same dimensions as the end caps Publ ication 1769 TD003A EN P November 2000 Allen Bradley In today s competitive environment when you buy any product you Support expect th
9. Description Backplane Current Value 600 mA at 5V dc 0 mA at 24V de Operating Temperature 0 to 60 C 32 to 140 F Storage Temperature 40 to 85 C 40 to 185 F Relative Humidity 5 to 95 non condensing Power Supply Distance Rating 4 The controller must be within four slot positions of the power supply Vibration Operating 10 to 500 Hz 5G 0 030 mm in peak to peak Shock Operating 30G 11 ms panel mounted 20G 11 ms DIN rail mounted Non operating 40G panel mounted 30G DIN rail mounted Shipping Weight 0 325 kg 0 715 Ibs Battery 1747 BA Programming Cable 1747 CP3 or 1756 CP3 Agency Certification C UL certified under CSA C22 2 No 142 UL 508 listed CE compliant for all applicable directives Hazardous Environment Class Class Division 2 Hazardous Location Groups A B C D UL 1604 C UL under CSA 22 2 No 213 Radiated and Conducted Emissions EN50081 2 Class A Electrical EMIC The unit has passed testing at the following levels ESD Immunity IEC1000 4 2 4 kV contact 8 kV air 4 kV indirect Radiated Immunity IEC1000 4 3 10 V m 80 to 1000 MHz 80 amplitude modulation 900 MHz keyed carrier Fast Transient Burst IEC1000 4 4 2 kV 5 kHz Surge Immunity IEC1000 4 5 1 kV galvanic gun Conducted Immunity IEC 1000 4 6 10V 0 15 to 80 MHz 1 Conducted Immunity
10. F Continuous Current per n a 8A 2 5A Common max Continuous Current Per 2 0 A at 60 C 140 F 4 0A at 60 C 140 F 16A Module max 4 0 A at 30 C 86 F 8 0A at 30 C 86 F Signal Delay max turn on 1 2 cycle turn on 0 1 ms turnon 1 0ms _ turnon 0 1 ms turn on 10 ms turn on 10 ms turn off 1 2 cycle turn off 1 0 ms turn off 2 0 ms turn off 1 0 ms turn off 10 msjturn off 10 ms Specifications Voltage Category 1769 106XOW4 Input and Output Specifications 1769 106XOW4 24V dc sink source inputs AC DC normally open relay outputs Operating Voltage Range inputs 10 to 30V de at 30 C 86 F and 10 to 26 4V de at 60 C 140 F outputs 5 to 265V ac or 5 to 125V de Number of Inputs 6 Number of Outputs 4 Number of Commons per Module 2 one for inputs one for outputs Input Compatibility IEC Type 1 Input Signal Delay max on delay 8 0 ms off delay 8 0 ms Output Signal Delay max resistive load turn on 10 ms turn off 10 ms Continuous Current per 2 5A outputs Point max Continuous Current per 8A outputs Common max Publication 1769 TDO03A EN P November 2000 Specification Analog Normal Operating Ranges CompactLogix Analog 1 0 Modules 1769 IF4 Input Specifications 1769 1F4 Voltage 10V dc 0 to 10V dc 0 to 5V de 1 to 5V de Current 0 to 20 mA 4 to 20 mA Number of I
11. addresses symbols instruction blocks rungs or other application objects This convenience lets you accomplish a task within a single menu and reduces your need to memorize the locations of features in the menu bar In addition for even greater time savings and convenience RSLogix 5000 provides an automatic type ahead feature that works with the instruction set and tag database to speed your data entry and programming Flexible ladder and function block diagram editors let you create application programs with ease Both function block and ladder routines coexist seamlessly in a single controller so you can choose the most appropriate language to program each component of your application You can also upload both ladder diagram and function block diagram code and tag name definitions from your controller This simplifies maintenance because you can always obtain the original source directly from the controller RSLogix 5000 programming software is the tool used to configure your CompactLogix controller and its related modules System Requirements Device Requirement Computer IBM compatible Pentium 90 MHz or greater Operating System Microsoft Windows NT version 4 0 with Service Pack 4 RSLinx software must be installed Memory 32 Mbytes of RAM minimum 64 Mbytes of RAM maximum Hard Disk 40 Mbytes of free hard disk space or more based on application requirements Display 16 color VGA graphics adapter 640 x 480 resolution
12. and system integrators around the world Allen Bradley FEAMEIE DOGE Americas Headquarters 1201 South Second Street Milwaukee WI 53204 USA Tel 1 414 382 2000 Fax 1 414 382 4444 ROCKVELL EEN Rockwell European Headquarters SA NV avenue Herrmann Debroux 46 1160 Brussels Belgium Tel 32 2 663 06 00 Fax 32 2 663 06 40 Asia Pacific Headquarters 27 F Citicorp Centre 18 Whitfield Road Causeway Bay Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Automation Publication 1769 TDO03A EN P November 2000 2000 Rockwell International Corporation All Rights Reserved Printed in USA
13. at can be re used on multiple machines or applications Networks The CompactLogix system also provides you with peer to peer communications to legacy devices via the following communication interface devices e DH 485 via 1761 NET AIC e DeviceNet via 1761 NET DNI Ethernet via 1761 NET ENI 1 DH 485 communication is not available with the R7 release of RSLogix 5000 DH 485 communication will be available in a future revision 2 Available Spring 2001 Publication 1769 TDO03A EN P November 2000 Publication 1769 TDO03A EN P November 2000 CompactLogix The Controller The 5320 controller also provides you with the following s features and functionality e 3 position keyswitch e Battery backed memory e Channel 0 default communication push button e Built in RS 232 port e 7 diagnostic LEDs e Integrated Compact 1769 Bus Compact 1 0 The 5320 controller is designed to directly connect to existing Compact I O modules Compact I O provides system expansion beyond the limits of one power supply e front access removal and insertion e removable terminal blocks for easy installation and replacement You can DIN rail or panel mount the controller and I O Together the CompactLogix controller and Compact I O provide you with a truly scalable system solution A simple system can consist of only a stand alone controller in a single bank of I O modules eyes When configuring your pombactiaunk mi ol
14. at product to meet your needs You also expect the PP manufacturer of that product to back it up with the kind of customer service and product support that will prove you made a wise purchase As the people who design engineer and manufacture your Industrial Automation Control equipment Allen Bradley has a vested interest in your complete satisfaction with our products and services Allen Bradley offers support services worldwide with over 75 Sales Support Offices 512 authorized Distributors and 260 authorized Systems Integrators located throughout the United States alone plus Allen Bradley representatives in every major country in the world Contact your local Allen Bradley representative for e sales and order support e product technical training e warranty support support service agreements ControlLogix FlexLogix CompactLogix Compact RSLogix 5000 and PanelView are trademarks of Rockwell Automation All other trademarks are copyrights of their respective companies Reach us now at www rockwellautomation com Wherever you need us Rockwell Automation brings together leading brands in industrial automation including Allen Bradley controls Reliance Electric power transmission products Dodge mechanical power transmission components and Rockwell Software Rockwell Automation s unique flexible approach to helping customers achieve a competitive advantage is supported by thousands of authorized partners distributors
15. competitive price Compact I O provide users with the following features e Modular system allowing mixing modules to suit the application e Feature rich I O functionality to address a wide range of applications e Rackless design eliminating added system costs and inventory e Small footprint shrinking panel space requirements e Front insertion and removal reducing assembly and replacement time e Unique tongue and groove interlocking case design ensuring a strong mechanical connection between modules e Integral high performance I O bus e Software keying preventing incorrect positioning within the system e Analog I O AC DC relay 24V dc and 120 240V ac voltages Available modules include Catalog No Description 1769 IA16 16 point 120V ac Input Module 1769 IA8I 8 point Individually Isolated 120V ac Input Module 1769 0A8 8 point 120 240V ac Output Module 1769 IM12 12 point 240V ac Input Module 1769 1016 16 point 24V de Sinking Sourcing Input Module 1769 0B16 16 point 24V de Sourcing Output Module 1769 OB16P 16 point 24V de Sourcing Output Module with Electronic Protection 1769 OV16 16 point 24V de Sinking Output Module 1769 0W8 8 point ac dc Relay Output Module 1769 OW8l 8 point Individually Isolated ac dc Relay Output Module 1769 IO6XOW4 Combination 6 point dc Input and 4 point Relay Output Module 1769 IF4 4 channel analog current voltage Input Module 1769 OF2 2 chan
16. g on line editing The CompactLogix controller has seven diagnostic LEDs on the front of the controller to indicate controller mode I 0 connection status forces enable status battery status controller fault indication default communication configuration active and RS 232 port activity Allows maintenance personnel to determine the current operating condition of the controller The on off state of each discrete output point and data value of each analog output channel can be individually programmed to hold the state value reset the state value or go to a User defined state on off for discrete outputs or a particular value for analog outputs Provides the ability to pre determine the mode change and failure operation of the outputs based on their unique application requirements The CompactLogix controller includes a default communication push button Provides a quick and easy way to restore the default serial port configuration and directly connect to the controller with the programming software Modular and rackless construction with front access removal and insertion DIN rail or panel mountable integrated high performance serial bus and removable terminal blocks Provides greater flexibility lowers cost of inventory and commissioning eases initial assembly and speeds module replacement UL C UL and CE certified Conforms to global standards allowing for easy shipment around the world 1 DH 485 communication is not avai
17. ime than traditional hard wired systems Plant wide and cell level data sharing DH 495 via the Data sharing between controllers 1761 NET Al Compatibility with multiple Allen Bradley PanelView devices Connection to dial up modems for remote program maintenance DF1 Full Duplex or data collection DF1 Half Duplex Connection to modems such as leased line or radio modems for Slave use in SCADA systems Remote Terminal Unit RTU functions See DH 485 DeviceNet and DF1 Half Duplex network examples on page 13 for additional information 1 DH 485 communication is not available with the R7 release of RSLogix 5000 DH 485 communication will be available in a future revision 2 Available Spring 2001 CompactLogix 13 Local DH 485 Network ACH AIC with AIC Interface e ae J ae HA j BEE DH 485 PanelView 550 AIC MicroLogix 1200 MicroLogix 1500 CompactLogix Local DeviceNet Ethernet Network DNI ENI SLC 5 03 DNI ENI SLC 5 03 with DNI ENI Interface E EE DNI ENI Personal a Co
18. ion Expansion Bus Cables Cable Type Catalog Number Length Right bank to right bank expansion 1769 CRR1 f ft 305mm Right bank to right bank expansion __ 1769 CRR3 3 28 ft 1 m Right bank to left bank expansion 1769 CRL1 1 ft 305 mm Right bank to left bank expansion 1769 CRL3 3 28 ft 1 m 1 Approximate cable length is measured from end to end of the cable only Using the Power Supply in a CompactLogix System Use the Expansion Power Supplies to increase your system s capacity for adding I O modules Bank 1 A 1769 I O power supply is limited in the amount of 5V dc and 24V dc current it can supply to the modules in its I O bank These limits depend on the catalog number e g 1769 PA2 of the supply A bank of modules should not exceed the current limits of the I O bank power supply Refer to the Compact Expansion Power Supplies Installation Instructions 1 An 1 0 bank is a group of 1769 1 0 8 modules maximum and a single 1769 O power supply 2 The CompactLogix controller must be within four slot positions of the power supply CompactLogix Specification Nominal Supply Voltage Power Supplies Specifications 1769 PA2 120 240V ac no jumpers 1769 PB2 24V de 1769 PA4 120 240V ac selector switch 1769 PB4 24V de Voltage Range 85 to 265V ac wide range no jumper or DIP switch 19 2 to 31 2V de 85 to 132V ac or 170 to 265 switch selectable
19. l j CompactLogix system a total of Controller eight Compact 1 0 modules may be used in a maximum of two banks of 1 0 modules One additional bank of I O modules can be added The first bank includes the CompactLogix controller in the far left position Each bank requires its own power supply and the controller must be within four slot positions of the power supply A maximum of one controller may be used in a CompactLogix system CompactLogix Controller f 1 An I O bank is a group of I O modules connected directly to one another Banks are separated by cables CompactLogix 5 Applications The CompactLogix system is an ideal choice for RTU SCADA applications requiring a cost effective modular solution CompactLogix provides an excellent solution for many industries including e Material Handling Distributed Processing e Assembly Machines e Food Processing e Packaging e RTU applications SCADA e Water Waste Water Pumping Filtering e HVAC Energy Management e Oven Control e Pharmaceuticals Publication 1769 TDOO3A EN P November 2000 Compact 1 0 Modules Publication 1769 TDO03A EN P November 2000 CompactLogix Designed as PLC style I O Compact I O modules are vertically oriented with removable terminal blocks Their rackless design integrated bus and front access insertion and removal features contribute to their superior functionality at an extremely
20. lable with the R7 release of RSLogix 5000 DH 485 communication will be available in a future revision 2 Available Spring 2001 CompactLogix System Overview CompactLogix is a powerful yet compact new control system It provides an ideal solution for your smaller machine level control applications including RTU SCADA applications requiring a low cost modular solution Programming The CompactLogix system is configured and programmed with RSLogix 5000 the Microsoft Windows NT package shared by other Logix controllers Multiple programming language support including ladder and function block diagram provide programming flexibility to meet the demands of a wide variety of applications CompactLogix uses the Logix control engine which means CompactLogix supports the Logix instruction set tasking model and data model e By sharing the same instruction set as all other Logix controllers application programs created for other Logix controllers can be easily ported to the CompactLogix controller The multi tasking operating system supports four configurable tasks that can be prioritized for executing the program code according to the application Tasks can contain up to 32 programs each containing separate routines providing a high level of application program organization Symbolic addressing lets you identify data by its use in the application independent of the hardware You can create libraries of standard routines th
21. mputer CompactLogix MMI Local DF1 Half Duplex Network b RS 232 DF1 Half Duplex Protocol Rockwell Software RSLinx 2 0 or higher SLC 5 03 SLC 5 04 and SLC 5 05 or PLC 5 processors Mill ZA modem configured for DF1 Half Duplex Master ZA Pek CompactLogix CompactLogix SLC 5 03 CompactLogix Slave Slave Slave Slave 1 DH 485 communication is not available with the R7 release of RSLogix 5000 DH 485 communication will be available in a future revision 2 Available Spring 2001 Publication 1769 TDO03A EN P November 2000 Programming Software i a Publication 1769 TD003A EN P November 2000 CompactLogix RSLogix 5000 programming software is IEC 1131 3 compliant software that supports the CompactLogix controller Operating on Microsofts Window NT 32 bit operating system the software maximizes performance saves development time and improves productivity RSLogix 5000 part of the RSLogix family of software products offers the same reliable functionality Drag and drop editing lets you quickly move instructions rungs of logic routines programs and tasks either within a single project or between two copies of RSLogix 5000 to create project libraries Context menus for common software tools are quickly accessible when you click the right mouse button on
22. nel analog current voltage Output Module 1769 IR6 6 channel RTD Resistance Input Module 1769 IT6 6 channel Thermocouple mV Input Module 1 Available in January 2001 CompactLogix Expansion I 0 Module Specifications Discrete Input Specifications Specification 1769 IM12 1769 1A16 1769 1016 1769 IA8I Voltage Category 200 240V ac 100 120V ac 24V dc sink source 100 120V ac Voltage Range 159 to 265V ac 79 to 132V ac 10 to 30V dc at 30 C 86 F 79V ac to 132V ac at 47 Hz at 47 Hz to 60 Hz at 47 Hz to 63 Hz 10 to 26 4V dc at 60 C 140 F to 63 Hz Number of Inputs 12 16 16 8 Number of Commons per 20 alt 2 8 Module Signal Delay On Delay 20 ms max Off Delay 20 ms max On Delay 8 ms max Off Delay 8 ms max On Delay 20 ms max Off Delay 20 ms max Input Compatibility IEC Type 1 1 This module has two internally connected common terminals Discrete Output Specifications Specification 1769 0A8 1769 0B16 1769 OB16P 1769 0V16 1769 0W8 1769 0W8I Voltage Category 100 to 240V ac 24V dc 24V dc AC DC normally open relay Operating Voltage Range 85 to 265V ac at 47 to 20 4 to 26 4V dc source 20 4 to 26 4V de 5 to 265V ac 63 Hz sink 5 to 125V de Number of Outputs 8 16 8 Number of Commons per 2 1 2 8 Module Continuous Current per 0 25A at 60 C 140 F 0 5A at 60 C 140 F 2 5A Point max 0 5A at 30 C 86 F 1 0A at 30 C 86
23. nputs 4 differential or single ended Resolution max 14 bits minimum unipolar 14 bits plus sign bipolar with 50 or 60 Hz filter selected Normal Mode Rejection Ratio Voltage 10 dB at 50 Hz 12 dB at 60 Hz Current 15 dB at 50 Hz 18 dB at 60 Hz Input Impedance Voltage Terminal 200K Q Current Terminal 250 Q Overall Accuracy Voltage Terminal 0 2 full scale at 25 C Current Terminal 0 35 full scale at 25 C Module Error over Full Temperature Range 0 to 60 C 32 F to 140 F Voltage 0 3 Current 0 5 Field Input Calibration Not required Channel Diagnostics Over or under range by bit reporting 1 Includes offset gain non linearity and repeatability error terms Specification Analog Ranges 1769 OF2 Output Specifications 1769 OF2 Voltage 10V dc 0 to 10V dc 0 to 5V de 1 to 5V de Current 0 to 20 mA 4 to 20 mA Number of Outputs 2 single ended Resolution max 14 bits minimum unipolar 14 bits plus sign bipolar with 50 or 60 Hz filter selected Conversion Rate all channels max 2 5ms Current Load on Voltage Output 5 mA max Resistive Load on Current Output 0 to 500 Q includes wire resistance Load Range on Voltage Output gt 1k Q at 5V de gt 2k Q at 10V de Field Calibration None required Overall Accuracy Voltage Terminal 0 5 full scale at 25 C Current Terminal
24. r to the table below for information on CompactLogix 1769 Compact I O and related publications Title CompactLogix System User Manual Publication Number 1769 UM007A EN P CompactLogix5320 Controller Installation Instructions 1769 INO47A EN P Logix5000 Controllers Common Procedures Programming Manual 1756 PM001A EN P Logix5000 Controller General Instruction Set Reference Manual 1756 RMO003B EN P Compact 1 0 System Overview 1769 S0001A EN P Compact 1769 Expansion 1 0 Installation Instructions for your particular module Installation Instructions are included with each module Also available via www theautomationbookstore com 1769 INxxx Compact 1 0 Communication Bus Expansion Cables Installation Instructions 1769 IN014A US P Compact 1 0 End Caps Terminators 1769 INO15A US P CompactLogix5320 Controller Installation Instructions 1769 IN047A EN P Compact Expansion Power Supplies Installation Instructions 1769 INO28A EN P Compact 1769 Expansion 1 0 Power Supplies and Cables Technical Data 1769 TD001A US P 1769 Compact Discrete Input Output Module Technical Data 1769 2 1 To purchase a manual or download a free electronic version visit us at http www theautomationbookstore com Publication 1769 TDO03A EN P November 2000 Specifications Publication 1769 TDO03A EN P November 2000 CompactLogix CompactLogix Controller 1769 L20
25. t in RS 232 programming port supporting DF1 Full and Half Duplex protocols DH 485 protocol and ASCII support Provides for direct connection for programming operator interface devices and ASCII devices as well as dial in remote programming Allows for networking of up to 255 devices communications using modems such as radio modems or leased lines and remote programming monitoring By using the DH 485 communication interface CompactLogix can be connected to a DH 485 network of up to 32 devices for data sharing via peer to peer messaging The DeviceNet communication interface provides a connection to a DeviceNet network of up to 64 devices with slave I O peer to peer messaging and program upload download capability The Ethernet communication interface provides a connection to an Ethernet network with peer to peer messaging and program upload download capability CompactLogix allows you to choose the network that best meets your needs If your application requires Use this network e High speed data transfer between information systems and or Ethernet via the a large quantity of controllers 1761 NET ENI 2 Internet Intranet connection Program maintenance e Connections of low level devices directly to plant floor DeviceNet via the controllers without the need to interface them through 1 0 1761 NET DNI modules e More diagnostics for improved data collection and fault detection Less wiring and reduced start up t

Download Pdf Manuals

image

Related Search

Related Contents

触覚マウス API(OCX)取扱説明書  Technical Service Manual  BA DHL 8_11 - V-Zug  e Owner`s Manual with Assembly Instructions f Guide de l  MODE D`EMPLOI USER MANUAL    Guía rápida FRENIC-Lift Variador dedicado para las aplicaciones  仕様書 イ牛 名 局所モニタ移設及び計測環境の整備  Installationsanleitung 3000LS  Massive Suspension light 38365/11/10  