1. 86 F or higher UPS CONTROLS AND CONNECTIONS Figure 1 Front Panel LEDs LED3 LED4 amber red LED1 LED2 green amber On Off button EMERSON Network Power e Inthe event of an emergency press the OFF button and disconnect the power cord from the AC mains to properly disable the UPS e Do not attach power strips or surge suppressors to the UPS e Do not attempt to service any parts inside the UPS except the batteries Failure to adhere to this could cause personal injury or equipment malfunction and void the warranty e For technical support e Visit www liebert com or e Send an e mail to upstech emersonnetworkpower com Step 4 Start the UPS After the battery is fully charged e Turn on the UPS by pressing the On Off button see Figure 1 below LED 1 should be illuminated green indicating the UPS is operating in Normal Mode Step 5 Connect the Loads The UPS has three battery backup sockets that provide power when the UPS operates on bat tery see Figure 2 below e Plug the loads into the battery backup sockets on the rear of the UPS UA Caution Do not connect a laser printer to the UPS Step 6 Connect the Network Surge Protection The UPS has two RJ 45 jacks for network lines see Figure 2 below e Connect a single line network cable into the RJ 45 network surge protection IN jack on the rear of the UPS e Connect an RJ 45 cable from the OUT jack on the rear of the UPS to
2. Battery Type VDC x Ah x Quantity Typical Recharge Time K 2008 Liebert Corporation Technical Support Service United States All rights reserved throughout the world Specifications subject to change without notice Liebert is a registered trademark of Liebert Corporation 800 222 5877 Outside U S 614 841 67 55 1050 Dearborn Drive EMERSON Alnames referred to are trademarks or registered trademarks of their respective owners upstech emersonnetworkpower com P O Box 29186 i r SLI 23301_ REVO 03 08 Web site www liebert com Columbus OH 43229
3. a port on a PC or network device such as a router Step 7 Set Up Liebert shutdown software To start using the Liebert shutdown software e Install the Liebert shutdown software See the software user manual for installation instructions Connect one end of the USB cable supplied to the USB port on the rear of the UPS Connect the other end to a USB port on the computer See the software user manual for operating instructions Figure 2 Rear Panel USB interface RJ 45 jacks 2 network protection Battery backup Surge sockets 2 Mains Fault sockets 6 IEC 320 C13 symbol eymne IEC 320 C13 Battery Overload symbol symbol f N Mains ANY breaker N EMERSON Liebert PSA Network Power AC Power System AC mains inlet UPS Status Alarm Conditions and Alerts Battery Mode LED 2 Flashes every 3 seconds Every 3 seconds Battery Low LED 2 Flashes every 1 second till end of discharge EOD Every 1 second Battery Replacement LED 4 Red Flashes every 1 second for 5 seconds only Every 1 second for 5 seconds only LED 4 Red Solid steady glow until UPS shuts down after 5 seconds Continuous until UPS shuts down REPLACING THE BATTERY To replace the battery 1 Turn off all connected loads then turn off the UPS batteries are NOT hot swappable 2 Use a Phillips head screwdriver to remove the two top cover screws from Steps 2 and 3 the back of the UPS l lt 3 Slide the top panel backw
4. Liebert PSA amp Quick Start Guide 1000VA 1500VA 230V IMPORTANT SAFETY INSTRUCTIONS e Do not connect equipment that may overload the UPS or demand half wave rectification such as a laser printer e Connect the UPS only to an earthed grounded socket that meets electrical safety guidelines e Locate the UPS near a wall socket Do not use an extension cord between the UPS and the socket e Use CE marked cables only for connections between mains the UPS and equipment e The Liebert PSA has been designed for small office nome office use only it is NOT recommended for use in life support applications SETUP Step 1 Inspect the Package Inspect the package and the UPS upon receipt Notify the carrier and dealer of visible damage EMERSON Network Power Liebert shutdown software CD Quick start guide UPS Step 2 Decide Where to Place the UPS The UPS must be placed indoors protected from water direct sunlight and excessive heat Provide at least 100mm 4 of clearance on all sides of the unit for proper ventilation Step 3 Charge the UPS Battery Before Use The UPS battery is not charged before shipping It MUST be charged before use e Connect a user supplied power cord from the UPS to a wall socket and charge for at least eight hours Note If battery is placed in storage charge the battery every six months if kept at 15 C to 29 C 5 F to 85 F or every three months if kept at 30 C
5. ard 13mm 1 2 Slide the front panel upward then pull outward to remove it 4 Gently pull the batteries out of the UPS 5 Remove the black wire from the negative terminal and the red wire from the positive terminal Be 6 Verify that the replacement battery matches the dimensions and battery 1 type in the Specifications section below AY a 7 Connect the battery leads to the new batteries Be sure to reconnect the red wire to the positive terminal and the black wire to the negative terminal D A W ST TT Steps 4 and 5 Note Small sparks may occur at the battery connectors during reconnection 8 Slide the batteries into the UPS 9 Reposition the front panel and slide downward until it slides into place Slide the top panel forward until flush with the front panel Reinsert the two top cover screws removed in Step 2 uw Lu Dispose of the old batteries properly at an appropriate recycling facility TROUBLESHOOTING If the UPS malfunctions during operation check the following chart for proper adjustment For further assistance please contact your local Emerson Network Power representative Problem Possi
6. ble Causes Solutions The UPS may not be turned on e Press the On Off button to turn on the UPS Mains is normal but LED 1 is not illuminated The power cord may not be connected properly e Connect the power cord securely into a wall socket The upstream mains circuit breaker may be tripped e Reset the circuit breaker LED 2 flashes amber every 3 seconds but there is Baten voltage naive too low E T A enous no output power An beeps continuously although mains is The UPS may be overloaded check LED 2 F Disconnbe cone sudismentrontheties UPS does not provide expected backup time The UPS battery reached end of life e Replace the internal battery The UPS is on and connected to mains but fails to l m l e f mains is normal try reconnecting mains and Mains may be outside the unit s operating range i operate properly restarting the UPS 0 lt m O gt O Z U Model Number PSA1500MT3 230U Say Net Weight kg Ib 9 5 20 9 11 6 25 6 Shipping Weight kg Ib 10 7 23 6 12 8 28 2 Dimensions W x D x H mm in 147 x 360 x 234 5 8 x 14 2 x 9 2 160 287VAC 50 60Hz 5Hz Typical 185 252VAC Output Voltage Battery Operation 230VAC 5 On Line Mains Voltage On Line Frequency Output Voltage Mains Normal On Battery Wave Form Stepped sinewave 12V x 7 2Ah x 2 12V x 9Ah x 2 6 8 hours to 90 Battery Run Time 60 100 minutes Agency Battery run time may vary depending on load