Home
K2-2代 -BC-2000 英文版2012-7-9.cdr - ADSF
Contents
1. Keypad Lockout amp Alarm Output options If there are 10 invalid cards or 10 incorrect PIN numbers in succession either the keypad will lockout for 10 minutes or the alarm will operate depending on the option selected below Normal status No keypad lockout or alarm factory default 7 O Factory default setting Keypad Lockout NM Alarm Output 7 2 7 To remove the alarm To reset the Door Forced Open warning Read valid card or Master Code To reset the Door Open Too Long warning Close the door or Read valid cardijor Master Code 8 Resetting To Factory Default Setting To reset to factory default power off press hold it and power on release it until hear three beeps two short one long means reset to factory default successfully Remarks Reset to factory default the user s information is still retained 9 Technical Specification Dimensions L135 mmXW58 mmXH26 mm K2 10 Package Listing Wiring Connections Wall Fixing Plug Used for fixing Self TapPINg Screws Used for fixing UK D AUTOMATIC ENTRANCE SPECIALISTS KP911 User manual e eje EJee Lh Technical 01275 871787 O NAVARRA Puertas Automatic Doors
2. Contents 1 Introduction 1 2 Specifications 1 3 Important Information 1 4 Mounting 2 Wiring 2 6 Detailed Programming Guide 4 6 1 User Settings 4 6 2 Relay Setting Pulse mode Toggle mode 5 6 3 Alarm Settings Door Detecting 6 7 To Remove The Alarm 6 8 Resetting To Factory Default Setting 7 9 Technical Specification T 10 Package Listing 7 1 Introduction All programming is done through the keypad Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure It can store 1 000 users with card and 4 6 digits password codes It has one relay output with 3 Amp changeover contacts 2 Specifications 1 Programmable Functions Relay momentary Relay strike time Pulse mode Toggle mode Change Codes 1 master 1000 users 2 Programmable Timers Door relay time 1 99 seconds Alarm time 1 3 minutes 3 Pulse Mode Toggle Mode 4 Wiring Connections Electric lock External bell External Push Switch Magnetic Contacts Alarm 5 12V DC Metal shell keypad 12 keys with backlight 3 Important Information If holes are to be drilled before mounting o
3. 99 seconds the factory default setting is 5 seconds Every time a valid tag card or PIN is read input in Pulse Mode the relay will operate for the pre set relay pulse time Toggle mode 4 O Every time a valid tag card or PIN is read inputin Toggle Mode the relay changes state which will not turn back until read card or input PIN again Toggle mode 6 3 Alarm Settings Door Detecting Alarm output time To set the alarm output time 1 3 minutes Factory default is 1 minute 5 1 3 Door Open Detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened by force or if the door is opened after 120 seconds of the electro mechanical lock not closed properly the inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 1 3 minutes with the default being 1 minute To disable door open detection RIOT Factory default To enable door open detection 611
4. Users can be deleted continuously without exiting from programming mode To delete a PIN or acard user To unlock the door HE To unlock the door for a PIN user Enter the PIN then press To unlock the door for a card user Present the card 6 Detailed Programming Guide 6 1 User Settings x Master code 9999 is the default factory master code To enter the programming mode To exit from the programming mode Note that to undertake the following programming the master user must be logged in 0 New code New code The master code is any 4 6 digits To change the master code Setting the working mode Set valid card only users 3 0 by card only Set valid card and PIN users 3 1 by card and PIN together Set valid card or PIN users 3 2 by either card or PIN default To set a user in either card or PIN mode 3 2 Default setting 1 User ID number PIN The ID number is any number between 000 999 The PIN is any 4 6 digits between 0000 999999 with the exception of 1234 which is reserved Users can be added continuously without exiting from programming mode as follows To add a PIN user User ID no 4 PINI User ID
5. mer into the mains until all wiring has been completed and the front cover secured Alarm Current 200mA DC1 2V 3A D m Yellow ES ea o Bue no Electric bolt NC Electric strike NO Purple COM Orange i Common Power Supply DC12V 3A WY YY Y Yellow Door detectingswitch e E Purse cow ranae Special Power Supply Power on After all wiring is completed and the unit face plate is attached to the back plate power on the red LED will be flashing Quick Reference Programming Guide Master code 999 is the default factory master code To enter the programming mode oO To exit from the programming mode x Note that to undertake the following programming the master user must be logged in 0 New code New code The master code can be 4 6 digits long To change the master code 1 User ID number PIN The ID number is any number between 000 999 The PIN is any 4 6 digits between 0000 999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode To adda PIN user 1 Read Card Cards can be added continuously without exiting from programming mode To add acard user 2 User ID number for a PIN user or 2 Read Card for a card user
6. mode Then allocate the card a PIN as follows Read card 1234 PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in card and PIN mode Method 2 Note that this is done outside programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the card ID number Old PIN New PIN New PIN 2 User ID To seta card user in card mode 3 0 To Add and Delete a card user The operating is the same as adding and deleting a card user in 3 2 To delete All users To delete ALL users Note that this is a dangerous option so use with care 2 0000 To unlock the door For a PIN user H Enter the PIN then press For a card User Read card For a card and PIN user Read card then enter PIN 6 2 Relay Setting Pulse mode Toggle mode Pulse mode Factory default Pulse mode Door relay time setting 4 1 99 The door relay time is between 1
7. no 2 PIN 2 User ID number Users can be deleted continuously without exiting programming mode To delete a PIN user To change the PIN of a PIN user This step must be done out of programming mode ID number Old PIN New PIN New PIN To add a card user Method 1 This is the fastest way to enter cards using ID number auto generation Read card Cards can be added continuously without exiting programming mode To add a card user Method 2 This is the alternative way to enter cards using User ID Allocation In this method a 1 1D number ReadCard User ID is allocated to a card Only one user ID can be allocated to a single card To delete a card user by card number Note users can be deleted continuously 2 Read Card without exiting programming mode To delete a card user by user ID This option can be used when a user has lost their card 2 User ID To set a card and PIN user in card and PIN mode 3 1 To Add a card and PIN user The PIN is any 4 6 digits between 0000 amp 999999 with the exception of 1234 which is reserved Add the card as for a card user Press to exit from the programming
8. nto a wall check for hidden cables and or pipes before drilling Use safety goggles when drilling or hammering in cable clips Every effort has been made to provide accurate information however slight variations can occur We also reserve the right to make changes for product improvement at any time NOTE please read these instructions carefully before attempting to install Internal Interface Circuit 1 Alarm output interface See Figure 1 2 Electric lock interface See Figure 2 Figure 1 Figure 2 4 Mounting 1 Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws 2 When wiring has been completed attach the front cover to the rear plate FARRER Ey Figure 3 Figure 4 5 Wiring 1 Unplug the cable harness and connect the necessary cables See Figure 3 2 Tape any wires that are unused 3 Plug in the cable harness on the PCB See Figure 3 4 attach the front cover See Figure 4 Terminal Wire Connector Function e ALARM Grey Nam Swichednegativewnenacive 7 open Yellow To Door EXIT Request Button Then Negative e DIN Brown To Door Contact Then To Negative 5 av 91206 Positive Regulated Power Input no Blue Door Strike Relay NO com Purple Door Strike Relay Com Nc Orange Door Strike Relay NO Negative Regulated Power Input N C Do not plug the power supply or transfor