Home
CL2X8-D1S2 CC-Link/LT Remote I/O Module User`s Manual
Contents
1. PRECAUTIONS DE CONCEPTION 2 The PRODUCT has been designed and manufactured for the purpose of being 2 This index indicates the degree to which conductive material is generated in terms WIRING PRECAUTIONS A ATTENTION used in general industries of the environment in which the equipment is used A WARNING MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY INCLUDING Pollution level 2 is when only non conductive pollution occurs A temporary Ne pas grouper ni placer proximit les cables de commande ou cables de BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED conductivity caused by condensing must be expected occasionally Completely turn off the externally supplied power used in the system when communication avec les cables des circuits principaux et ou d alimentation Cabler ON CONTRACT WARRANTY TORT PRODUCT LIABILITY FOR ANY 3_ It can also be used in an environment other than on the control panel if the installing or placing wiring Not completely turning off all power could result in en pla ant ces cables a une distance d au moins 100mm 3 94 pouces des cables INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY conditions such as usage ambient temperature and humidity are satisfied electric shock or damage to the product des circuits principaux i de l alimentation Cela pourrait tre a l origine d un bruit CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN 2 2 Performance specifications parasite entr
2. CL2X8 D1S2 CC Link LT Remote I O Module Thank you very much for purchasing this product Please read this manual thoroughly before starting to use the product and handle the product properly User s Manual MODEL CL2X8 D1S2 U MODELCODE 13JP23 IB NA 0800256 D 1406 MEE 2003 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Read these precautions before using Please read this manual carefully and pay special attention to safety in order to handle this product properly Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the user s manual of the CPU module to use for a description of the programmable controller system safety precautions Before using this product please read this manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly In this manual the safety precautions are classified into two levels A WARNING and A CAUTION WIRING PRECAUTIONS PRECAUTIONS D INSTALLATION A CAUTION A ATTENTION Perform correct wiring for the module according to the product s rated voltage and terminal arrangement Connecting to a power supply different from rating or miss wiring may cause fire and or product failure Fix terminal screws securely within the regulated torque Loose terminal screws may cause fire and or malfunction If the terminal s
3. Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2480 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Australia When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to c
4. coms coms come coms coms Joona LINK PW Num ros de broche et noms des signaux L UINKIPW Num ros de borne et noms des signaux TEJE JESEILDETLIELT E Jocasaloc2al xo x1 x2 xa xa xs x6 x7 z e 8 opi pu e e ao locassloc248 come coms coms coms coms come coms coms number to 32 6 External Dimensions Station Ten s place One s place number 40 20 10 js 4 p 1 32 OFF ON ON OFF OFF ON OFF 4 Connector Connector for CC Link LT communication line and module power for CC supply Link LT interface 5 Terminal Terminal block for connecting input signals and external power block for I O supply of the input part interface 6 Hook for DIN rail 4 Handling Precautions TY 1 Tighten the terminal screws for the module to the specified torque shown below Insufficient tightening torque could result in shorts failures or malfunction Hook for installing the module on a DIN rail Module mounting screw M4 screw 0 78 to 1 08 Nem 69 2 72 4 5x5 1 elongated mounting hole M4 screw A EN 60 5 2 38 0 4 0 02 45 40_ Oey T
5. s2 3 times each in 3 directions X Y Z dysfonctionnements du module 1 Operating No corrosive gases PRECAUTIONS DE MISE AU REBUT atmosphere Operating 0 to 2000m A ATTENTION altitude Lors de sa mise au rebut ce produit doit tre trait comme un d chet industriel Installation Inside a control panel 3 location CON DITIONS OF USE FOR TH E PRODUCT Overvoltage Il or less category 1 Mitsubishi programmable controller the PRODUCT shall be used in dogres z Zorless conditions i where any problem fault or failure occurring in the PRODUCT if any shall not lead to any major or serious accident and ii where the backup and fail safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem fault or failure occurring in the PRODUCT 1 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the rated voltage of 300V is 2500V
6. strip length is toolong the exposed conductive part may cause electric shock or short circuit If the wire strip length is too short it may result in a poor contact to the spring clamp terminal part 3 When using a spring clamp terminal block tool follow the instruction below Failure to do so may cause damage of the spring clamp terminal part or the terminal block resin part Use a dedicated tool for a spring clamp terminal block Do not insert the wire or the bar solderless terminal before inserting the tool into the square shaped hole Insert the tool vertically into the hole Square shaped hole Circular shaped hole Wire strip length 8mm to 11mm U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang
7. 3mA or higher time expiration error 24 VDI Negative common 24 VDC Re ee OFF voltage OFF current 11V or lower 1 7mA or lower LERR On Indicates that a communication data error has se 1 0024A e 1 DCA Cable removal occurred or the setting switch is outside the E U 2 DC24B 1 Insert the tool vertically all the way inside the square shaped hole of the remote I O Input resistance 5 6kQ allowable range 4 3 DC24A mod le i 1 4 DC24B Response Response time 0 5ms High speed 1 5ms Standard type Flicker at regular intervals 1 o 5 x0 F gt R time setting response type Indicates that the setting switch has been 6 COMB ii 2 Pullithe wire or the bar solderiess terminalldutonithe hole OFF gt TYP 0 05ms Ec changed while current is being conducted The 7 x1 eS ON module continues to operate even while the s a p MAX 0 1 ms 1 5ms LED is flickering The changed settings will be 10 COMB 4 i ON gt TYP 0 2 ms reflected when the power has been restored x3 t 1 OFF Flicker at irregular intervals y 12 COMB i MAX _ 0 5 ms fams Indicates that the terminal resistor is left 1 XT B 4 1 Common wiring method 8 points 1 common terminal block 2 wire type unconnected or that the module or connection 15 XS i i Input method Positive common negative common shared type cable are affected by noise a B i Number of stations occupied In 4 point mode Occupies 2 stations Qr No
8. Tel condition OFF 1 5ms Standard type External power supply of the input part Alimentation externe de la partie entr e U S A Mitsubishi Electric Automation Inc First transient noise burst IEC 61000 4 4 1kV 3 Station Select 10 20 or 40 to set the ten s place of the station 24 VDC 24Vcc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Withstand voltage 500V AC for 1 minute between primary external DC number number i ii i ie i Tel 1 847 478 2100 i terminal and secondary intemal Heat setting Select 1 2 4 or 8 to set the one s place of the station St ee for I O Interface Negative Feu interface E S commun Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda z switches number gi Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Insulation resistance JOM OF dan penean ths ene DC femmina SW1 to 7 All switches are set to OFF at shipment from the factory Connector for CC Link LT interface Connecteur pour interface CC Link LT Paraiso Sao Paulo SP Brazil Bay AG ay m ernal ey Ja or measured with a Always set the station number within the range of 1 to 64 Terminal block for I O interface Positive Bornier pour interface E S commun Tel 55 11 5908 8331 TEON Fesistance westel A setting error occurs and L ERR LED flickers if the value common positif Germany Mitsubishi Electric Europe B V German Branch Protection class IP2X outside the range 1 to 64 is set Insulation Isolation Gothaer Strass
9. a nant des dysfonctionnements APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS SS EEE WIRING PRECAUTIONS PRECAUTIONS OR WARNING CONTAINED IN MITSUBISHI S USER The performance specifications for the remote I O module are shown in the following A CAUTION INSTRUCTION AND OR SAFETY MANUALS TECHNICAL BULLETINS AND table GUIDELINES FOR the PRODUCT Terminal screws which are not to be used must be tightened always Otherwise there will be a danger of short circuit against the bare solderless terminals Number of inputs 8 points 5 Wiring Cable Installation T EREE EE RRT 14 Operating LED name Confirmation details Connector for 1 Insert the tool vertically all the way inside the square shaped hole of the remote I O Isolation method Photocoupler isolation status PN On Pawer sup ly on CC Link LT interface CL2X8 D1S2 iriodule Rated load voltage 24V DC indicator Off The power supply is turned off or the voltage nauleton 2 Insert the wire or the bar solderless terminal into the circular shaped hole and Rated input current Approx 4mA LEDs drop is too large i a i L remove the tool from the hole Max simultaneous ON input 100 L RUN On Normal communication Revere cusses Pama aed 3 a DEPE 3 Check that the wire or the bar solderless terminal is firmly clamped by pulling it a k icati supply of the i points Off Communication cutoff input part for I O interface inputpart Terminal Bick 1 lightly ON voltage ON current 19V or higher
10. a paj T z F o e amp 05 S v S G ponon se S S g 3 Center of DIN rail BE A S d aag gagga H 64 5 installation hole M4 screw Unit mm inch 7 Cable Installation Procedure 40 1 57 Precaution for installing or removing cables Terminal block mounting screw M3 screw 0 42 to 0 58 Nem 2 When using a DIN rail attach the DIN rail after taking the following items into consideration Applicable DIN rail types conform to JIS C 2812 TH35 7 5Fe TH35 7 5Al Interval between the DIN rail s installation screws Tighten the screws using a pitch of 200mm 7 87in or less when attaching a DIN rail 3 To attach the remote I O module to the DIN rail press the centerline area of the DIN rail hook beneath the module until a click is heard 4 Maintain some distance between the module and other components and parts 10 mm from the top and 50mm 1 97in from the bottom of the module in order to improve ventilation and to make replacement of the module easy if a remote I O module is installed on a board 5 Install the remote I O module on a level surface If the surface is uneven unnecessary force is applied to the printed circuit board causing malfunctions 1 Insert only one wire into the circular shaped hole of the spring clamp terminal block Inserting two or more wires may result in a poor contact to the terminal part 2 Strip the wire according to the specification If the wire
11. crews are too tight it may cause short circuit or erroneous operation due to damage of the screws Make sure foreign objects do not get inside the module such as dirt and wire chips It may cause fire product failure or malfunction STARTING AND MAINTENANCE PRECAUTIONS A WARNING Do not touch terminals when the power is on Doing so could cause an electric shock Switch off all phases of the externally supplied power used in the system when cleaning the module or retightening the terminal or module mounting screws Not doing so could result in electric shock STARTING AND MAINTENANCE PRECAUTIONS A CAUTION Utiliser le module dans un environnement conforme aux sp cifications g n rales pr sent es dans ce manuel L utilisation de ce module dans un environnement autre que celui pr vu dans les sp cifications g n rales peut tre l origine d un choc lectrique d un d part de feu ou d un dysfonctionnement ou peut endommager ou d t riorer le produit Eviter tout contact direct avec les parties conductrices du module Cela pourrait tre l origine de dysfonctionnements ou autres probl mes avec le module Serrer le module fermement avec un rail DIN ou avec des vis de fixation serr es dans les limites du couple de serrage prescrit Sile serrage des vis est insuffisant ily a risque de chute du module de court circuit ou de dysfonctionnement Un serrage excessif peut endommager les vis et il
12. e 8 D 40880 Ratingen GERMANY Weight 0 12kg Example Set the switches as below when setting the station Tel 49 2102 486 0 1 O part connection method M thode de raccordement de la partie E S Module installation method 2 piece 20 point spring clamp terminal block Bornier trier 2 pi ces 20 points DIN rail installation mounted by screws of type M4x0 7 mmx16 mm or larger Can be installed in six directions 0 3 to 1 5mm AWG22 to 16 0 3 1 5 mm 22 16 AWG Applicable wire size Taille du fil a utiliser 3 Part Names This section explains the names of the components for the remote I O module 1 WELSEB___c 2x8 D1s2 l MITSUBISHI p 3 2 FON 8588888 e 27 J Ey SSF ON o gt fy a ano 421 Bre STATIONNO 5 OEEEEEEEEEELO Oleee coo ays 6 Pin numbers and signal names Terminal numbers and signal names Se a ARIEILIEALIE E locasaloc2sal xo x1 x2 xa xa xs xe x7 Zz 47 e 7s oppa e 2 locassloc248 come coms coms
13. hange without notice
14. l in a safe place for future reference DESIGN PRECAUTIONS A WARNING Configure an interlock circuit in a sequence program so that the system operates on the safety side using the communication status information in the event the data link falls into a communication problem Otherwise erroneous output and malfunction may result in accidents Input could be switched on or off when a problem occurs in the remote I O modules So build an external monitoring circuit that will monitor any input signals that could cause a serious accident DESIGN PRECAUTIONS A CAUTION Do not have control cables and communication cables bundled with or placed near by the main circuit and or power cables Wire those cables at least 100mm 3 94 inch away from the main circuit and or power cables It may cause malfunction due to noise interference INSTALLATION PRECAUTIONS A CAUTION Use the module in an environment that meets the general specifications contained in this manual Using this module in an environment outside the range of the general specifications could result in electric shock fire erroneous operation and damage to or deterioration of the product Do not directly touch the module s conductive parts Doing so could cause malfunction or trouble in the module Tighten the module securely using DIN rail or installation screws within the specified torque range If the screws are too lose the module may dro
15. la pourrait tre temperature l origine d un choc lectrique Operating 5 to 95 RH non condensing Avant le nettoyage du module ou le resserrage des vis de borne ou des vis de ambient fixation du module couper les alimentations externes utilis es par le syst me sur humidity toutes les phases Faute de quoi il y a risque de choc lectrique Storage ambient PRECAUTIONS DE DEMARRAGE ET DE MAINTENANCE humidity A ATTENTION Vibration Compliant Frequency Constant Half Sweep resistance with JIS B acceleration amplitude count Ne pas d monter ni modifier le module Cela pourrait tre a l origine de pannes de 3502 and Under 5 to 8 4Hz 3 5mm 10 times dysfonctionnements de blessures ou d un d part de feu IEC intermittent 7 each in Ne pas faire tomber le module ni le soumettre de forts chocs Cela risquerait 61131 2 Vibration 8 4 to 9 8m s e XYZ d endommager le module 150Hz directions Couper compl tement l alimentation externe utilis par le syst me avant de mettre en place ou de retirer le module Faute de quoi il y a risque d endommagement du Under 5 to 8 4Hz 1 75mm_ produit continuous 4 to 4 9m s Avant de toucher au module se d barrasser de la charge lectrostatique vibration 450Hz qu accumule le corps humain en touchant un objet m tallique raccord la terre Shock Compliant with JIS B 3502 and IEC 61131 2 Le non respect de cette pr caution peut tre a l origine de pannes ou de resistance 147 m
16. p from its installation position short circuit or malfunction If the screws are too tight the screws may be damaged which may cause the module to drop from its installation position or short circuit DISPOSAL PRECAUTIONS A CAUTION When disposing of this product treat it as industrial waste PRECAUTIONS DE SECURITE Lire ces pr cautions avant usage Pri re de lire attentivement ce manuel Pr ter une attention particuli re a tout ce qui a trait a la s curit pour utiliser le produit correctement Ces pr cautions ne concernent que l quipement Mitsubishi Dans le manuel de l utilisateur du module CPU correspondant voir l expos des pr cautions de s curit concernant le syst me de l automate programmable Avant d utiliser ce produit lire attentivement ce manuel ainsi que les manuels auxquels il renvoie et toujours consid rer la s curit comme de la plus haute importance en manipulant le produit correctement Dans ce manuel les pr cautions de s curit sont class es en deux niveaux a savoir A AVERTISSEMENT et JN ATTENTION A AVERTISSEMENT Attire l attention sur le fait qu une n gligence peut cr er une situation de danger avec risque de mort ou de blessures graves Attire l attention sur le fait qu une n gligence peut cr er une situation de danger avec risque de bles
17. rmal communication L 18 COMB a WARRAN T Y In 8 or 16 point mode Occupies 1 station Oto7 Displays the ON OFF status of the input turned on 01 9 oan He gt Module Voltage 24V DC 15 to 20 ripple ratio within 5 inthe ON statusand turm d of in the OFF status k K Mitsubishi will not be held liable for damage caused by factors found not to be the power supply Current 4OmA or lower When 24V DC and all point is on 2 response ot the responce time OFF ON ON gt OFF time of the remote cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi consumption itch g OFF i E default f All COM B and DC24B terminals are connected within the module common products damage secondary damage accident compensation caused by special Gurrenton TOMA or lower 24V DC fea R ae eich t bara a isbeadireeponsaltvoels The power to the module is supplied via the power adapter factors unpredictable by Mitsubishi damages to products other than Mitsubishi startup set y put Ign SPI p YP Toutes les bornes COM B et DC24B sont connect es l int rieur du module products and to other duties Noise durability DC type noise voltage 500Vp p noise width tps noise Be sure to set response time in consideration of the environment commun L alimentation du module se fait via l adaptateur d alimentation carrier frequency 25 to 60Hz noise simulator ON z 0 5ms High speed response type Country Region Sales office
18. specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail safe redundant or other safety features which exceed the general specifications of the PRODUCTs are required For details please contact the Mitsubishi representative in your region 1 Overview This user s manual explains specifications and names of individual parts of the CL2X8 D1S2 type CC Link LT remote I O module hereinafter abbreviated as remote I O module 2 Specifications 2 1 General Specifications The General specifications for the remote I O module are shown in the following table Fixer les vis de borne fermement en serrant au couple prescrit Des vis de bornes Operating 0 to 55 C desserr es peuvent tre a l origine d un d part de feu et ou de ambient 0a55 C dysfonctionnements Si serrage excessif des vis de bornes peut les endommager temperature et tre a l origine d un court circuit ou d un fonctionnement erratique Temp ratur Veiller viter toute p n tration d impuret s copeaux de c blage ou autre corps ambiante tranger dans le module Cela pourrait tre l origine d un d part de feu ou du de panne ou d un dysfonctionnement du produit fonctionne PR CAUTIONS DE D MARRAGE ET DE MAINTENANCE ment Storage 25 to 75 C AVERTISSEMENT ambient Ne pas toucher aux bornes quand l appareil est sous tension Ce
19. sures l g res ou de gravit moyennes ou risque de d g ts mat riels A ATTENTION Dans certaines circonstances le non respect d une pr caution de s curit introduite sous le titre N ATTENTION peut avoir des cons quences graves Les pr cautions de ces deux niveaux doivent 6tre observ es dans leur int gralit car elles ont trait la s curit des personnes et aussi du syst me Veiller ce que les utilisateurs finaux lisent ce manuel qui doit tre conserv soigneusement port e de main pour s y r f rer autant que de besoin PR CAUTIONS DE CONCEPTION AVERTISSEMENT Pr voir dans le programme s quentiel un circuit de verrouillage sur la base des informations d tat de la communication de fa on maintenir la s curit de fonctionnement du syst me dans l ventualit d un probl me de communication affectant la liaison de donn es Faute de quoi une sortie erron e ou un dysfonctionnement pourrait tre l origine d accidents L entr e peut tre activ e ou d sactiv e la survenance d un probl me dans les modules E S distants On constituera donc un circuit de surveillance exteme couvrant tous les signaux d entr e qui pourraient tre l origine d un accident grave PR CAUTIONS DE C BLAGE A ATTENTION Les vis des bornes qui restent inutilis es doivent toujours tre serr es Faute de quoi il y a danger de court circuit par con
20. tact avec les bornes barres sans soudure Effectuer le c blage du module correctement compte tenu de la tension nominale du produit et en respectant l affectation des bornes Le raccordement d une alimentation de tension nominale diff rente ou une erreur de c blage peuvent tre l origine d un d part de feu et ou d une panne du produit Prohibited Application Prohibited Applications include but not limited to the use of the PRODUCT in Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medical applications Train equipment transport equipment such as Elevator and Escalator Incineration and Fuel devices Vehicles Manned transportation Equipment for Recreation and Amusement and Safety devices handling of Nuclear or Hazardous Materials or Chemicals Mining and Drilling and or other applications where there is a significant risk of injury to the public or property Notwithstanding the above restrictions Mitsubishi may in its sole discretion authorize use of the PRODUCT in one or more of the Prohibited Applications provided that the usage of the PRODUCT is limited only for the
21. y a risque de d tachement du module et de court circuit PRECAUTIONS DE CABLAGE A AVERTISSEMENT Couper compl tement l alimentation externe utilis par le syst me avant de mettre avant le c blage ou le raccordement de c bles Ne pas couper compl tement toutes les alimentations expose au risque de chocs lectriques et d endommagement du produit Do not disassemble or modify the module Doing so may cause failure malfunction injury or fire Do not drop or apply any strong impact to the module Doing so may damage the module Completely turn off the externally supplied power used in the system before mounting or removing the module Not doing so could result in damage to the product Before touching the module always touch grounded metal etc to discharge static electricity from the human body etc Not doing so can cause the module to fail or malfunction WARNING Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in minor or moderate injury or property damage Under some circumstances failure to observe the precautions given under A CAUTION may lead to serious consequences Observe the precautions of both levels because they are important for personal and system safety Make sure that the end users read this manual and then keep the manua