Home
User Manual ELECTRONIC KEYPAD LEVERSET WITH
Contents
1. select user to edit user information will be shown select Edit select X Delete 4 You must communicate changes to lock before they are recognized at the lock see Transfer below B Select Transfer you can send data setting changes to the lock view lock activity or get data settings from the lock 1 Sending data to Lock to communicate any user adds edits or deletes along and any settings changes 2 Viewing lock activity lock activity on app is from last update you will need to select Get new lock activity to view the latest activity 3 Getting data from Lock to communicate latest user and setting data from the lock to the app Select Setting you can customize some of the lock and app features 1 From the settings screen you can edit the noted settings scrolling down is Advanced Settings Select Logoff when you are done or when you want to program a different lock Battery Status when BT communications are successful an Operation Complete screen gives you a battery status 1 Good means battery has the power to operate lock and BT communications 2 Low means battery still has power to operate lock and BT communications but should be replaced Lock LED shows 4 amber flashes and 4 beeps 3 Blackout means the battery can no longer operate lock and battery must be replaced Lock LED shows 6 red flashes and 6 beeps 4 Replacement battery should be a high guality 9 volt alkaline battery B
2. user codes will work only key operates lock 6 Delete all codes 7 Set 4 digit code length 8 Set 6 digit code length 9 Beeper ON 10 Beeper OFF 11 Extended timeout OFF 12 Extended timeout ON enter 5 and then 5 again enter 5 and then 2 enter 5 and then 3 enter 1 and then 1 again enter 1 and then 2 enter 2 and then 1 enter 2 and then 2 again factory setting is 4 digits factory setting is ON factory setting is OFF Extended timeout mode allows for a longer duration of unlock time upon entry of a valid user code 13 Passage switch OFF 14 Passage switch ON enter 4 3 and then 2 factory setting is ON Passage switch mode ON choose between Passage lock unsecured and Privacy always locked and OFF lock is always in Privacy always locked enter 1 and then 4 enter master code to confirm 15 Restore factory defaults Feedback LED and Beeper Condition Comment Power On Normal Power on Factory default reset Battery low Battery blackout Access granted normal Access granted battery low Access denied normal Access denied Battery blackout Access denied lockout ID input during timeout Passage Switch Lock secured Lock unsecured amber Manual Programming Programming active Blinks to off on key press Programming operation success Programming operation failed Programming cancelled Programming time out After 20 seconds Bluetoo
3. EMTEK ASSA ABLOY User Manual LISCIO ELECTRONIC KEYPAD LEVERSET WITH BLUETOOTH PROGRAMMING ASSA ABLOY the global leader in door opening solutions LISCI ELECTRONIC KEYPAD LEVERSET WITH BLUETOOTH PROGRAMMING 2 Lever buttons Keyed Cylinder O Thumbturn S Using the Lock Once installed on door with the battery connected your lock is ready for use Factory Default Setting User amp Master Codes are labeled on the inside trim plate and page 7 of this user manual Entering User Codes Entering a correct active user code green LED x1 amp beep x1 unlocks Entering an incorrect or inactive code red LED x2 amp beep x2 remains locked Three incorrect entries will result in lockout signaled by 3 red LED flashes amp 3 short beeps lockout lasts for 30 seconds To Restart Code Entry Press and hold 1 button for three seconds this works in entry or programming mode Key Access Lock may also be unlocked and locked via keyed cylinder each lock comes with two keys Passage amp Privacy Mode Use inside thumbturn Setting Setting Description Thumbturn Position LED Feedback Thumbturn Lock access is regulated Enable ON A correct active user code e Green is required for access Privacy Mode Thumbturn Lock access is NOT regulated O Amber Enable OFF Always Unclocked Passage Mode Getting Started Device App App is A B free and available
4. at App Store Apple devices or Play Store Android devices From Apple devices iPhone 45 5 5S amp 5C iPad 3rd generation and later running iOS 6 1 and later 1 Go to App Store select Search enter Emtek select Emtek Liscio Bluetooth select download icon when ready select Open If upon opening app you receive a screen that advises you that your device is Unsup ported you will not be able to run app on this device From Android devices OS 4 3 and later 1 Go to Play Store select Search icon enter Emtek select Emtek Liscio Bluetooth app select Install select Accept when ready select Open If app does not appear then your device is running OS prior to 4 3 Once App is opened you will be on the Welcome screen 1 selecting Start you will move through the setup wizard lock will need to be nearby for this 2 select Videos Quick Reference About or Show Phone Info as needed 3 If you call Emtek for customer service please have the information listed in the Show Phone Info available Programming Features Once App is setup and you have logged into app you will be on the Home screen from here you can A B D E Select Users you can add edit and delete users 1 To add user select New enter Name and enter user code factory set at 4 digits 2 To edit user select user to edit user information will be shown select Edit edit as needed select Update 3 To delete user
5. attery is located behind the interior trim plate 3 Troubleshooting Verify that device meets minimum requirements A Apple iPhone 45 5 55 and 5C iPad 3 generation and later running iOS 6 1 or later B Android running OS 4 3 or later Re pairing App Function A Use this action when device to lock communications are not working but were previously and several retries have failed B How to 1 App Navigate to Login screen enter the app password select the door name move slider Force Re Pairing to ON and then press Login button 2 Lock Manually reset lock to factory defaults press 1 and 5 buttons simultaneously enter master code press the 1 and then the 4 buttons not simultaneously and reenter the master code LED will blink green once that lock has been reset OR disconnect battery and when you reconnect battery hold down any button for 3 seconds reset will be signaled by LED flashing 3 times and 3 beeps Once reset the lock s activity log will be empty and the user and master codes will be back to factory defaults see labels placed on page 7 of User Manual booklet and inside of the interior trim plate 3 Follow app wizard through setup process 4 Transfer user and master codes and settings on app to lock Reset App and Lock A Use this action when re pairing app function does not restore Bluetooth communications This will reset app and lock deleting activity log and reset user and mast
6. er codes back to factory defaults B How to 1 App Navigate to Settings screen scroll down and select Advanced Settings select Clear database at Select desired action select Delete this application database for Confirm delete move slider to ON then select Commit Changes You will be sent back to Welcome screen to start setup wizard from the beginning 2 Device Apple Navigate to main Settings select Bluetooth select i icon for Emtek 1 under DEVICES select Forget this Device and confirm Forget Device Android Navigate to main Settings select Bluetooth select Emtek 1 icon on right side and then select Unpair 3 Lock Manually reset lock to factory defaults see section 2 above 4 Follow app wizard through setup process 5 This will reset all information both app and lock If problem still persists Remove App from Device download again reset lock A Use this action when action 2 above does not correct Bluetooth communications B How to 1 Device Apple Press on Emtek icon until all icons shake and have x at corner of apps select x on Emtek app press Apple Home Button and apps will return to normal Go to App Store and download app again and open to start again Android Navigate to main Settings select Apps scroll to find the Emtek icon and press then select Uninstall 2 Device Apple Navigate to main Settings select Bluetooth select i icon for Emtek 1 under DEVICES se
7. lect Forget this Device and confirm Forget Device Android Navigate to main Settings select Bluetooth select Emtek 1 icon on right side and then select Unpair Device Cycle power off then back on Lock Manually reset lock to factory defaults see section 2 above Start Emtek app and follow wizard through setup process This will reset all information both app and lock nun Aw Manual Programming The lock can be programmed manually using the keypad buttons 1 through 5 This feature is made avail able but programming using smart phone is highly recommended Manual Programming commands A To enter programming mode press the 1 and the 5 buttons simultaneously B Enter the lock s 6 digit master code the master code will be on sticker on page 7 of user manual and inside trim plate of lock C The features below now accessible by entering a combination of two buttons one after the other not simultaneously 1 To add a code 2 To delete a code 3 To change master code 4 Deny Users ON 5 Deny Users OFF enter 1 and then 3 enter 3 and then 3 again enter 4 and then 1 enter 5 and then 1 factory setting is OFF then enter new code and enter again to confirm factory setting is 4 digit mode enter 4 and then 3 then enter code to delete and enter again to confirm then enter new master code and enter again to confirm Deny Users can disable or enable all user codes when ON no
8. th Programming BT enable interval Delay for entering BT Programming active Programming completed normal Programming completed battery low Programming completed battery blackout Programming cancelled or time out Programming failed After 60 seconds Key Press User Access Manual Programming Blink against solid amber FF 7 Place Sticker Here L IN8 LISCIO USER 8 6 2014 7 EMTEK ASSA ABLOY ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience Copyright 2014 Emtek Products Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Emtek Products Inc is prohibited
Download Pdf Manuals
Related Search
Related Contents
Progress Lighting P4693-09WB Installation Guide MÁQUINA DE HELADOS ROHO ® Matratzenauflagen (ca. 1MB) Dataram 16GB(2 x 8GB) DDR2-667 manuel d`installation et d`entretien des enrouleurs air-o Cooper Lighting LUMIERE CAMBRIA 290 User's Manual Copyright © All rights reserved.
Failed to retrieve file