image

Contents

1. a AAAS REM ee E e LA ee eee FOCA mn AAA ee OCC MC ME WE NNE Em o Reverse VIn L o Ee oo r OF FLOAT denas j Operating Manual Superlogic Professional Commercial Reverse Osmosis SuperLlogic Professional Commercial Reverse Osmosis HI a a b SuperLogic 1500 Installation and Operation Manual 370 Encinal Street Suite 150 Santa Cruz CA 95060 888 426 5644 Fax 831 336 9840 www hydrologicsystems com Superlogic Professional Commercial Reverse Osmosis ouperLogic 1500 Manual Superlogic 1 500 gpd system High tlow low energy membrane Automated TDS controller and moni tor with simultaneous feed and product readout Carbon fiber face plate Rinsable sediment and Eco Green Carbon block prefiltration Anti scalant cartridge for use in hard wa ter applications Brine and product flowmeters Pretilter In Out gauges Membrane In Out gauges Stainless steel waste water recirculation valve Stainless steel heavy duty commercial pump Low pressure cut off switch Non petroleum bioplastic fittings Manufactured in the USA All systems QC tested and verified 370 Encinal Street Suite 150 Santa Cruz CA 95060 888 426 5644 Fax 831 336 9840 www hydrologicsystems com Superlogic Professional Commercial Reverse Osmosis Introduction SuperLogic 1500 Manual Congratulations on the purchase of your SuperLogic commercial reverse osmosis
2. such as lost time inconvenience damage to personal property loss of revenue commercial losses postage travel telephone expenditures or other losses of this nature Some states do not allow the exclusion or limitation of incidental or consequential damages so this exclusion may not apply to you Owner s Warranty Responsibilities Under the provisions of this Warranty the owner is expected to perform timely maintenance as described in this Manual Neglect improper maintenance abuse or unapproved modifications may invalidate the Warranty Should your unit develop a defect or otherwise fail to perform in accordance with this warranty you should contact HydroLogic Implied Warranties Implied at law warranties of merchantability and fitness for a particular purpose shall terminate on the date one year after the date of purchase Note some states do not allow limitations on how an implied warranty lasts so the above limitations may not apply to you Other Rights This Warranty gives you specific legal rights and you may also have other rights that vary from state to state Returned Goods Authorization In order to process a return a Returned Goods Authorization RGA number will be assigned Include the RGA number with an explanation of the defect with the item being returned Items returned under the RGA process will be reviewed and or for warded to the original manufacturer for evaluation Items returned must be sent prepaid s1uauuu o
3. Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis Pre Installation Procedures PLEASE READ CAREFULLY FAILURE TO FOLLOW THESE PROCEDURES CAN RESULT IN DAMAGE TO YOUR SYSTEM AND VOID YOUR WARRANTY Packaging Upon delivery inspect packaging and report any damage to your carrier immediately After unpacking the system inspect it carefully for signs of damage All damage claims should be made to the delivery carrier Operating Parameters The SuperLogic 1500 system may only be used on potable water The user must be sure that water to be treated is both microbio logically safe and non toxic Ensure that the operating parameters outlined on page 3 are met at the installation site Items of most importance are TDS feed water pressure flow rate chlorine level and temperature range A water analysis is helpful in determining if any pre treatment is needed If your water analysis shows levels of substances in excess of the maximums contact HydroLogic for pre treatment recommendations Contact HydroLogic to inquire about a detailed water analysis Installation Start up Procedure PLEASE READ CAREFULLY FAILURE TO FOLLOW THESE PROCEDURES CAN RESULT IN DAMAGE TO YOUR SYSTEM AND VOID YOUR WARRANTY Location Locate the system where it will be protected from harsh conditions such as rain snow direct sunlight and extreme temperatures both hot and cold The SuperLogic 1500 system can be located just about anywhere there is
4. alarm optional and switch the dry contact position from the normal position to operate a valve pump etc Once the TDS level drops below the set point this will deactivate the light and alarm and switch the contacts back to the normal position normally open or closed NOTE The IN mode amp sensor does not have an alarm nor control set point It is a monitor only CONTACT INFO If you have any problems or questions regarding your controller please contact HM Digital Inc HM Digital Inc info hmdigital com 5819 Uplander Way www tdsmeter com Culver City CA 90230 1 800 383 2777 U S A BOX CONTENTS 1 Controller 3 Two sensor cables grey 5 Mounting brackets 2 Two sensors SP 1 4 Power cord black 6 U S plug adapter SPECIFICATIONS TDS Range 0 999 ppm mg L Resolution 1 ppm Accuracy 2 of the reading Temperature Compensation Automatic ATC 1 60 C Calibration Manual by trimmer pot calibration screw Set Point Single point controlled by on screen up down buttons to any point within the range Set Point Relay single isolated 2A Max 220V resistive load 100 000 strokes Relay Control out sensor only The unit will open or close a circuit via dry contacts when the ppm level of the OUT sensor aka product water reaches or exceeds the control setting simple switch It can be used to control a pump solenoid valve or other device Relay Voltage 5V the connected device needs its own power source Alarm O
5. calibration solution be sure the sensor is dry and free of any TDS residue If the reading on the controller does not match the calibration value you will need to re calibrate If using a fitting calibrate with the fitting on the sensor See step 5 for additional informa tion regarding the calibration value 4 For better accuracy calibrate to a flowing solution If this is not possible you can calibrate to a still solution Ensure the fitting is completely filled with solution and there are no air bubbles This step is critical for proper calibration 5 If the reading on the controller does not match the solution adjust the reading up or down by gently turning the trimmer pot calibration screw on the face of the unit marked as ADJUST clockwise or counterclockwise to raise or lower the reading 6 If calibrating to a still not flowing solution calibrate to 3 above the level of the calibra tion solution This will accomodate for the lack of flowing water which the controller is programmed for For example if the calibration solution is 342 ppm adjust the screw until it reads 352 ppm If you are calibrating to a flowing solution calibrate to the level of the solution 7 Gently release the screwdriver from the trimmer pot 8 Your controller is now calibrated There is no need to do anything else 4 TROUBLESHOOTING The controller willnot power on 1 Checkto ensure the connections are correct double check 110V vs 220
6. distributor contact HM Digital at info hmdigital com
7. iouis a e E C Ta 4 I 9 B ll j i j E B j 4 zi E E LI uu it s logic 370 Encinal Street Suite 150 Santa Cruz CA 95060 acao 2 Earth Friendly Company Built in USA P 888 426 5644 F 831 336 9840 info hydrologicsystems com Www super logic com p www facebook com hydrologicpurification Hudr loaic PURIFICATION SYSTEMS www super logic com PANEL CUT OUT DIAGRAM USER S GUIDE H 2 hein 68 mm 3 T D S dual mode PPM LULU 89 Ul 9 Z PS 200 ADJUST SET DOWN IN MODE 1 Using a knife cut the diagram out cut on the outer part of the line 2 Align the cut out to your panel and draw cut marks 3 Cut the hole in the panel to the precise dimensions of the cut out 2 11 16 in x 2 11 16 in 68 mm x 68 mm gt See the installation section for complete instructions Pp S 2 0 0 PANEL MOUNT DUALTDS NTROLLER MONITOR CONTACT DIAGRAM 110 220V BUZZ SENSOR OUT Thank you for purchasing HM Digital s PS 200 The PS 200 is a panel mount total dissolved solids TDS controller that monitors and controls levels of TDS in water The controller has a maximum set point to help maintain a limit of TDS allowed in the product water as well as a second sensor to monitor the TDS level of the feed water If the TDS level rises to the set point the controller will activate a warning light sound an
8. number and proof of date of purchase package and return to HM Digital Inc ATTN Returns 5819 Uplander Way Culver City CA 90230 U S A Implied Warranties Any implied warranties including implied warranties of merchantability and fitness for a particular purpose are limited in duration to five years from date of purchase Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you To the extent any provision of this warranty is prohibited by federal and state law and cannot be preempted it shall not be applicable This warranty gives you specific legal rights and you may also have other rights which vary from state to state NOTE Warranties are product specific Third party products and products deemed by HM Digital as accessories are not covered under warranty Third party products and accessories include but are not limited to batteries fuses mounting brackets plug adaptors and fittings INSTALLATION INSTRUCTIONS IMPORTANT Double check your contacts prior to connecting the controller toa power source Incorrect connections could result in shorting out the unit 1 Remove the contents from the box 2 Insert the controller into the panel A square hole must be cut into the panel with dimensions of 2 11 16 in x 2 11 16 in 68 mm x 68 mm Page 8 includes a cut out diagram 3 Mount the controller to the panel by inserting the mounting brackets into the gr
9. pressure gauge reads 120 psi 8 3 bar e Allow the system to flush for one hour with all water discharged to drain Periodically check for leaks and check the vessel in pressure gauge It is likely that the vessel pressure will drift from 120 psi 8 3 bar during the flushing If it does turn brine concentrate recirculation valve clockwise to increase pressure and counterclockwise to decrease pressure e The recirculation valve will need to be adjusted when membranes are replaced or if there are seasonal changes in water temperature that cause the pump pressure to drift by 10 psi or more e The 120 psi pressure provides the best compromise of membrane performance and lifetime while maintaining pump and motor longevity The system can operate above 120 psi and up to a maximum of 150 psi Inlet water temperature and TDS can effect the flow rate of purified water and in situations with low water temperatures and or high TDS increased pressure may be necessary to achieve desired flow rates of purified water DO NOT LET SYSTEM PRESSURE RISE ABOVE 150 PSI 10 3 BAR AS DAMAGE TO THE SYSTEM CAN OCCUR Performance Verification Factory test data is supplied with the system To ensure optimal performance on site data should be taken and compared to the fac tory test data This data should be taken after the system has been flushed for one hour Some deviations may be seen due to differences in feed water TDS and temperature between the site and facto
10. system This is professional water purification equipment which with proper care and maintenance can last you for many years Feed water conditions can vary drastically as well as fluctuate at your specific site In order retain your warranty the provided operating log must be maintained and available for our review Prior to starting up the SuperLogic reverse osmosis systems this user manual must be fully read and understood Keep this manual in a safe place for future reference A copy of this manual can be found at www hydrologicsystems com System Specifications HL Model Number 31043 Capacity gpd 1 500 4 x 21 high flow low energy thin film Number of Membranes Membrane TDS Rejection 10 rinsable sediment 5 micron 10 Green Carbon block 10 micron Pretreatment Anti scalant cartridge Membrane Type Pump o eh Motor stamp _____ Dimensions 18 Wx 26D x 30 H Weight 100 Ibs 7Based on membrane performance after 24 hours 77 F 25 C 500 ppm TDS 120 psi and 66 recovery Membrane performance may vary 159 Hudr Loaic PURIFICATION SYSTEMS Feed Water and Operating Specifications Important Note Feed water quality has a great effect on the performance of your reverse osmosis It is very im portant to meet the minimum feed water requirements Failure to do so will cause the membranes to foul and void the warranty Feed Pressure 40 80 psi 150 psi 40 100 F lt 0 3 p
11. the float switch Figure 2 Electrical Diagram BLACK WHITE GREEN LINE NEUTRAL 110 220 VAC 1Ph 50 60Hz SUPPLY 5 B BK 110 2200 7 WHT 110 220 TDS METER LINE OW PRESSURE SWITCH N O MOTOR RED 116 RED 10V SOLENOID VALVE NC 110 VAO MOTOR PUMP 110 OR 220 VAC e H dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 PURIFICATION SYSTEMS 888 426 5644 Fax 831 336 9840 www hydrologicsystems com Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis System Flush and Performance Verification Although SuperLogic 1500 systems are fully tested at the factory prior to shipping it is recommended to flush and verify your system s performance on site Flushing New membranes are shipped with a preservative that needs to be flushed out before use Run the product line to drain while flush ing the system e Fully open the brine concentrate recirculation valve by turning the knob counterclockwise e Turn on water supply to the unit and check for leaks at the pre filter housings and the feed connections e Plug the system into a compatible electrical outlet CAUTION THE SYSTEM WILL START and rapidly cycle starting and stop ping until the membrane vessels are full of water and water starts flowing out of the product and brine ports e After the system has run for a few minutes to clear any air turn the brine concentrate recirculation valve clockwise until the vessel in
12. 44 Fax 831 336 9840 www hydrologicsystems com Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis Anti Scalant Cartridge Allows the system to be operated at a 2 1 product to brine recovery ratio by preventing membrane fouling due to hardness in the feed water The system can also be specified for a 4 1 product to brine ratio if a proper water softener or anti scalant system is installed prior to the SuperLogic Contact us for details 888 426 5644 Brine Concentrate Recirculation Valve A needle valve that controls the amount of brine from the membrane to be recirculated back into the feed stream This feature allows for higher recovery rates lower waste water ratios Additionally adjustment of this valve regulates the pump discharge pressure Filter IN OUT Pressure Gauges Gauges that display the water pressure before and after the sediment prefilter Used to observe the pressure drop through the sediment prefilter a means of detecting filter clogging or loading Flow Control A fixed orifice that controls the amount of water flowing across the membrane to drain This controls the ratio for product water to waste water and either comes at a 4 1 or 2 1 ratio depending on how the system was specified Low Pressure Switch An electrical switch that shuts off the unit in the event of low feed water pressure This is used as a pump protection device This is factory set to cut off at 12 psi 0 8 bar Membrane Ve
13. Checks In addition to the daily checks it is recommended to repeat the procedure in the section on Performance Verification and record all data on a performance record sheet Semi Annual Service It is recommended to change both sediment and carbon filter cartridges at least every six months Carbon cartridges should be changed more often if bad taste and or odor becomes evident Sediment cartridge should be changed more often if water supply pressure and filter pressure gauges differ by 10 psi or more Peripheral Equipment Peripheral equipment such as tanks also have periodic maintenance requirements It is essential to maintain these as they can have a dramatic effect on the performance of your system Refer to their specific manuals for proper maintenance procedures e H dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 PURIFICATION SYSTEMS 888 426 5644 Fax 831 336 9840 www hydrologicsystems com Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis Filter Membrane Replacement Schedule Sediment pre filter The 5 micron sediment filter is pleated and can be rinsed with a garden hose You can rinse as often as needed but it is recommended to replace this filter every 6 months If you observe a 10 psi drop in the pre filter out gauge from the psi in the pre filter in gauge this indicates a clog in the sediment filter and you should either rinse it or replace it Carbon Pre Filter The 10 micron c
14. V 2 Check to ensure the power cable is plugged in Incorrect readings 1 Try to recalibrate the controller Note that the calibra tion should be done with a fitting on if using a fitting 2 Check for interference caused by other machinery or electronics near the controller or cables The relay control does not work 1 Double check the connections for contacts 12 13 amp 14 2 Make sure that the set point is properly set The display shows Err 1 The TDS level of the water is out of the controller s range 2 The sensor is not connected 3 The sensor is dirty or damaged The display shows the feed water 1 The sensors are reversed Connect the sensor for the TDS level instead of the product feed water to the IN sensor contacts and the sensor for the product water water to the IN sensor contacts If troubleshooting does not solve the problem please contact HM Digital for assistance If your controller is still under warranty please return the controller to HM Digital for repair or replacement see page 6 Cleaning To clean the sensor electrodes use rubbing alcohol and a cotton swab Lightly clean the electrodes Rinse with DI RO or distilled water Air dry Sensor Replacement If your sensor has been damaged you can purchase a new one model SP 1 without the need to purchase a new controller Contact your authorized HM Digital distributor for a replacement sensor If you cannot locate an HM Digital
15. a water supply and electrical outlet This system is equipped with casters and may be rolled to different locations for operation Keep in mind however that the system should be out of normal traffic patterns yet accessible for daily monitoring and service Plumbing Figure 1 Flow Diagram Always abide by local plumbing codes when installing the system Water Supply Connection Connect feed water supply line to the female garden hose connector Many other inlet fitting options are available through Hydro Logic If the supply water is being drawn from a non pressurized source gravity feed contact Hydrologic for additional information Minimum inlet pressure is 40 psi If your inlet psi is below 40 contact HydroLogic for further information Drain Connection Connect a 3 8 line from the quick connect elbow marked DRAIN to an appropriate drain point A quick connect drain saddle is avail able as an option from HydroLogic and can be plumbed directly into the main train of a sink Be sure to check your local plumbing codes to see if an air gap between the system and the drain is required Product Connection The product water connection to the storage tank should not be made until the system is flushed and tested as outlined below Tank Connection For Non Pressurized Tanks Only When using a non pressurized storage tank connect the 3 8 tubing marked PRODUCT to the tank Use an optional electronic float switch to shut down the system when th
16. arbon filter is rated at 2 PPM chlorine removal and should be changed according to the schedule below 4 1 ratio replace every 25 000 gallons of product water 2 1 ratio replace every 15 000 gallons of product water Anti Scale Pre Filter Should be replace every time the carbon filter is replaced Membrane Upon startup the vessel in gauge should read 120 while the vessel out gauge will always read approximately 10 psi less or 110 psi When the vessel out gauge reads 20 psi lower than the vessel in gauge or 100 psi this indicates when to change your membrane e H dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 PURIFICATION SYSTEMS 888 426 5644 Fax 83 1 336 9840 www hydrologicsystems com Limited Warranty This Limited Warranty extends to the original purchaser of the unit This warranty covers all parts and factory labor needed to repair any manu facturer supplied item that proves to be defective material workmanship or factory preparation The above mentioned warranty applies for the first full calendar year from the date of purchase These defective items are subject to the following exclusions membranes filters O rings and all other parts or components that require regular replacement as a result of ordinary usage Disclaimers This Warranty applies only if the unit is installed and used in compliance with the instructions enclosed with the unit The Warranty does not cover any unauthorized parts or part
17. e tank is full and start the system when water level is low Quick connect bulk head fittings are available to connect the product line to your tank Contact HydroLogic for this and other options available e H dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 888 426 5644 Fax 831 336 9840 www hydrologicsystems com PURIFICATION SYSTEMS 7 Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis Figure 1 Flow Diagram FLOW METER QD 0 2 GPM RO UNIT SUPERLOGIC 370 Encinal Street Suite 150 Santa Cruz CA 95060 888 426 5644 Fax 831 336 9840 www hydrologicsystems com Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis Electrical Figure 2 Electrical Diagram WARNING THE SYSTEM CAN START AT ANY TIME WHEN POWER IS CONNECTED DO NOT CONNECT POWER UNTIL THE SYSTEM IS COMPLETELY INSTALLED AND READY TO RUN The SuperLogic 1500 system is built with a standard 115v three prong plug Be sure the receptacle you use is on a circuit that has a Ground Fault Interrupter GFCI and has sufficient capacity for the operating current as listed in the system specifications It is recommended that the system be installed on a dedicated circuit to prevent overloading on system start up Optional External Float Switch Wiring For non pressurized tanks only A piggy back connector is supplied with the system Please see additional installation information included with
18. ooves on the bottom and top of the controller Fasten the brackets with the included screws 4 View the contact diagram on the side of the controller also on page 8 5 Do NOT connect to a power source yet Connect the black power cord to the contacts 8 amp 9 110 V 230V It does not matter which color wire is connected to the contacts Screw in tight with a Phillips head screwdriver Note If in the U S or a country that uses Type A or B plugs sockets connect the included plug adapter to the power cord 6 If using a pump valve etc connect a relay wire not included to contacts 13 and 14 fora normally open N O position OR to contacts 12 and 13 for a normally closed N C position 7 Connect a gray sensor cable by attaching the white wire to contact 1 the red to 2 and the black to 3 8 Connect the second sensor cable by attaching the white wire to contact 5 the red to 6 and the black to 7 The cables are identical and can be swapped 9 Align the pins of each sensor to each cable and attach Screw the tightening ring closed The sensors are identical and can be swapped Note which sensor is now the IN sensor and which is the OUT sensor 10 Insert each sensor electrode into a female 1 2 NPTF threaded fitting 11 Attach the fitting connected to the OUT sensor to the product water 12 Attach the fitting connected to the IN sensor to the feed water 13 Ensure the orientation of the sensor is perpendic
19. pm 5 000 ppm lt 5 SDI Max Operating Pressure Temperature Max Chlorine continuous Max Total Dissolved Solids Silt Density Index Turbidity lt 1 NTU pH Range Sa ipm Iron Hydrogen Sulfide or op Manganese 0 ppm Please Note Higher TDS and or lower temperatures will reduce the systems performance Detailed water analysis available All levels of pre and post filtration available to match source water Call HydroLogic directly for assistance 888 426 5644 370 Encinal Street Suite 150 Santa Cruz CA 95060 888 426 5644 Fax 831 336 9840 www hydrologicsystems com Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis Prefilter IN Gauge TDS Monitor Prefilter OUT Gauge Brine Concentrate Recirculation Valve Product Flowmeter Vessel IN Gauge Vessel Out Gauge Brine Flowmeter Sediment Prefilter Anti Scalant Solenoid Valve Pump Motor Low Pressure Switch Carbon Prefilter Membrane Vessel e dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 PURIFICATION SYSTEMS 888 426 5644 Fax 831 336 9840 www hydrologicsystems com Superlogic SuperLogic 1500 Manual Professional Commercial Reverse Osmosis Product Connection 3 8 Brine Connection 3 8 Feed Connection Garden Hose Thread Flow Control Product Water Check Valve e H dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 PURIFICATION SYSTEMS 888 426 56
20. ptional steady beep set by user Probe 12 NPTF bushing Cable Length 3 meter 9 8 ft shielded cable Display Bright tri color L E D Power Supply 110V 230V 10 Vac 50 60Hz Enclosure Front and back with ABS Environment 10 to 50 C 4 to 122 F RH max 95 non condensing Dimensions 7 2 x 7 2 x 10 2 cm 2 8 x 2 8 x 4 in Monitor Weight 476 grams 1 Ib 0 8 oz THIS PAGE INTENTIONALLY LEFT BLANK WARRANTY ONE YEAR LIMITED WARRANTY The PS 200 including the controller and both sensors is warranted by HM Digital Inc the Company to the purchaser against defective materials and workmanship for one 1 year from the date of purchase What is covered Repair parts and labor or replacement at the Company s option Transportation charges for repaired of new product to be returned to the purchaser What is not covered Transportation charges for the defective product to be sent to the Company Any consequential damages incidental damages or incidental expenses including damages to property This includes damages from abuse or improper maintenance such as tampering wear and tear water damage or any other physical damage The Company s products are not waterproof and should not be fully submerged in water Products with any evidence of such damage will not be repaired or replaced See additional note below How to obtain warranty performance Attach to the product your name address description of problem phone
21. ry If you have already connected the product line to the tank you will need to disconnect it to take product samples Flow Tests Determine the flow rates for both product and brine Put the product line into a container and measure the volume of water that flows into it in one minute Repeat the process with the brine drain line These values should be in either gallons per minute or milliliters per minute Product flow rates at 77 F 25 C should be within 1596 of the production rates given in the system specifica tions Product to Brine Concentrate Ratio Compute the product to brine ratio by dividing the brine flow rate by the product flow rate This ratio should be either 4 1 or 2 1 3096 The 30 variation can be due to inlet water temperature being above or below 77 degrees ferenheit as well as inlet TDS be ing above or below 500 PPM Total Dissolved Solids TDS rejection Using the TDS monitor note the TDS in both the feed water and the product water Calculate percent rejection using the formula Feed TDS Product TDS Feed TDS x 100 96 Rejection Rejection should be 8596 or better For example where the feed TDS is 600 and the product TDS is 24 the percent rejection is 600 24 600 x 100 96 e H dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 888 426 5644 Fax 831 336 9840 www hydrologicsystems com PURIFICATION SYSTEMS Superlogic SuperLogic 1500 Manual Professional Commercial Re
22. s not included on the original unit This Warranty does not cover the costs of repairs or adjustments to the unit that may be needed because of the use of improper parts equipment or materials This Warranty does not cover repairs required due to use of unauthorized parts unauthorized alterations of the unit failure of a unit caused by such alterations or by unau thorized repairs The Warranty does not cover malfunctions of the unit due to tampering misuse alteration lack of regular maintenance misapplication fouling due to hydrogen sulfide or iron scaling from excessive hardness or excessive membrane hydrolysis due to chlorine levels in excess of 1 0 mg L or operating at too high a recovery In addition damage to the unit due to fire accident negligence act of god or events beyond the control of the manufacturer are not covered by this warranty The manufacturer warranties the membranes per the original manufacturers warranty These warranties generally cover faulty material and workmanship for anywhere from one to three years Membrane fouling is not covered The manufacturer warranties all items supplied by outside vendors per the manufacturers warranties These warranties generally cover faulty material and workmanship for one year Incidental and Consequential Damages The manufacturer does not assume responsibility for payment of incidental damages as a result of the failure of this unit to comply with express or implied warranties
23. ssel Desalinator Separates dissolved solids from the feed water This assembly consists of a stainless steel pres sure vessel that houses the thin film reverse osmosis RO membrane Prefilter Carbon A 10 micron Eco Green carbon block prefilter that removes chlorine prior to entering the membrane Prefilter Sediment A pleated filter that prevents undissolved particles larger than 5 micron from entering the system Product Water Check Valve A one way valve that prevents pressurized product water from flowing back into the desalinator and possibly damaging the membrane when the system is off Pump Motor The rotary positive displacement pump boosts water pressure in the desalinator up to 150 psi 10 3 bar for low energy membranes to ensure high solids rejection and high flow rates Solenoid Valve Electrically operated valve that prevents water from flowing through the system when it is not in operation Vessel Pressure IN OUT Gauges Gauges that display the operating pressure before and after the RO membrane used to observe drop in membrane pressure indicating fouling or clogging TDS Monitor Simultaneously reports the feed and product water TDS in ppm Includes optional alarm function A low PPM limit can be programmed so the system shuts down if PPM s go above set point e H dr Lo C 370 Encinal Street Suite 150 Santa Cruz CA 95060 888 426 5644 Fax 831 336 9840 www hydrologicsystems com PURIFICATION SYSTEMS
24. the desired set point is reached Pressing once will ad vance the reading by a single digit Press and hold the button to advance the reading quickly 3 Press the SET button again This will save the set point to memory 4 If the EC level reaches the saved set point the controller will switch the contacts from the normal position either normally open or normally closed thereby operating the pump solenoid valve or other device attached to contacts 12 amp 13 or 13 amp 14 5 Once the EC level falls below the set point the contacts will switch back to the normal position 6 The alarm if connected will sound continuously while the EC level is over the set point The only way to turn it off is by lowering the EC level below the set point or disconnect ing the blue wire from contacts 5 and 11 Calibration Your controller was factory calibrated to 342 ppm NaCl This level is suitable for most tap water filtered water applications so it is ready to use out of the box However you may need to re calibrate based on your needs as well as from time to time to ensure best results To calibrate 1 Obtain a certified calibration solution that is correct for your needs The calibration solution should be NaCl HM Digital s 342 ppm NaCl is recommended 2 Calibrate to the OUT sensor This will calibrate both sensors simultaneously 3 Check the controller against the calibration solution Prior to inserting the sensor into the
25. ular to the flow of the water Water should flow equally over both pins If using a T if you look through the top of the T you should see both pins equally side by side If using the sensor in a tank ensure that there are no air bubbles trapped between the pins or in a fitting 14 To DISCONNECT the audible alarm disconnect the blue wire from contacts 10 and 11 15 Plug the power cord into an electrical outlet The controller does not have a power switch and will automatically power on when the power is connected USAGE INSTRUCTIONS 1 The controller will turn on when the power cord is plugged into an electrical outlet 2 Open the cover on the front of the controller by gently pulling down 3 There is only one display for both the IN mode feed water and OUT mode product water The OUT mode is the default To view the TDS level of the feed water press the IN MODE button The display will switch to the feed water NOTE The display will automatically switch back to the product water TDS after five seconds To view the feed water display for longer press and hold the IN MODE button 4 To turn off the controller unplug it from the electrical outlet USAGE INSTRUCTIONS continued Setting the Control Set Point 1 To set the control set point to activate a device via the relay press the SET button once The EC reading will switch to a flashing number the current set point 2 Press the UP or DOWN buttons until
26. verse Osmosis Low Pressure Switch Test While the system is running shut off the water supply to the system The system should shut off If the system does not shut off after ten seconds either unplug the system or restore the water supply to the system Call HydroLogic to diagnose problem DO NOT LET THE SYSTEM RUN WITHOUT THE WATER SUPPLY TURNED ON PUMP DAMAGE WILL OCCUR Tank Connection Make the tank connection as outlined on page 8 Optional Float Switch Test for non pressurized tanks The system should run when the float is hanging down by the power cord Tilt float up so the power cord is at the bottom of the float The unit should shut off If unit does not shut off re check installation procedure Operation and Maintenance SuperLogic 1500 systems are designed for simple operation with little user intervention We recommend keeping accurate performance records and following a regular preventative maintenance schedule to maximize the life of your system Daily System Checks Your water supply pressure can vary from time to time This can also affect your system operating pressure Check and adjust your vessel pressure daily to ensure maximum water production rates and quality Check both the prefilter in pressure gauge and pre filter out pressure gauge Under normal conditions there should be a 3 5 psi difference between the two gauges When the difference reaches 10 psi it is recommended to change your pre filters Monthly System

Download Pdf Manuals

image

Related Search

Related Contents

Ruckus Wireless™ ZoneDirector™ Release 9.7 User Guide  Temperature Controller TC01/02 Manual    SYSTEMTM  Tecumseh AVC5542EXN Performance Data Sheet  Philips CTX520GRY X520 Xenium  USER`S MANUAL - American Weigh Scales Inc  E0732-0_SPX-24A  Nespresso BEC800 Coffeemaker User Manual  CipherLab 1504 bar code reader  