Home
2.4 TFT Installation Instruction
Contents
1. 5 9 Connection with Wi Fi optional This fingerprint machine may provide Wi Fi that Short for wireless fidelity and is meant to be used generically when referring of any type of 802 11 network whether 802 11b 802 1la dual band etc to connect fingerprint machine with LAN the fingerprint machine is available to directly download data via Wi Fi our Wi Fi Support IEEE 802 11b compliant DBPSK DQPSK CCK modulation IEEE802 11b Standard Data Rates 1 2 5 5 and 11Mbps 28 2 4TFT Installation Instruction V1 1 1 Support IEEE 802 11g compliant DSSS CCK OFDM modulation JEEE802 11g Standard Data Rates 6 9 12 18 24 36 48 54Mbps For more detail operation see Appendix Wi Fi configure Note Unless you have configured the Wi Fi setting of this fingerprint machine the Wi Fi communication is invalid when you wish use the Wi Fi Following figure is illustration about how to apply Wi Fi to the terminal 29 Trouble Shooting 6 Trouble shooting Trouble Cause amp Measure Power LED is off Cause No power or lack of voltage Measure D Check and examine the connection of PWR GND make sure they contact well Measure the supply voltage ensure that it is 12VDC Device is unable to connect with PC Cause The connection problem Measure Check and examine the connection of RS232 RS485 or TCP IP whether its connection is correct or not After device power is LCD
2. ii A 18 3 2 7 RS485 connection i 18 3 2 8 Wiegand output connection 20 3 2 9 Connect with external Weigend reader 21 3 2 10 Power connection renn 21 3 3 Fastening fingerprint machine 23 4 Test and examine after installation 24 SrOthers a aerei loi eta 25 SI Resetiaraana alal RN annua 25 5 2 Anti dismantle button 25 5 3 Wireless doorbell a a a 26 5 4 U flash disk using renna 26 5 5 Built in EM card reader Optional 26 5 6 Built in MIFARE card reader Optional 27 5 7 Built in HID Card reader Optional 27 Contents 5 8 Cable doorbell Optional eee 28 5 9 Connection with Wi Fi optional 28 6 Trouble shooting naisieiai nisi aLaaa 30 APpendix silicati nia bei UA 32 How to configure the Wi Fi function for the terminal 32 2 4 TFT Installation Instruction V1 1 1 1 Before Installing 1 1 Notice about installing The terminal is a mass produced product It strictly follows to the criteria of manufacture and inspection of China U S A and EU This file contains important information It is better for you to read it carefully prior to use If you ignore it the
3. 1 gt n _ na x y Presi ye Gi a Hub and spoke wireless network 34 2 4TFT Installation Instruction V1 1 1 Ad hoc peer to peer wireless network Infrastructrue Model x select the wireless network model depending on the different click the draw down box to topology of network this Infrastructure Model will apply to Hub and Spoke wireless network the Ad hoc Model is used in the peer to peer wireless network Step 6 Select the Authentication Type The Infrastructure Model include five Authentication Type that are 35 Trouble Shooting OPEN SHARED WEPAUTO WPAPSK WPA2PS the Ad hoc Model include OPEN SHARED WEPAUTO WPANONE four type of Authentication Type Click the draw down box ita to select the Authentication Type Step 7 Select Encrypt Type When the item NONE of encrypt Type is selected then the password in WEP Wired equivalent privacy and WPA WiFi protested access item is not permitted to modify it it is not need to input password too According to Authentication Type and Encrypt Type Click draw down box metin to input the password password comply with the criterion set down by the software Note there are four group passwords in the WEP column till the all password have been set up is correct the current password is valid Step 8Set Connection Parameter The fingerprint machine fully support two connection ways one TCP IP
4. 4Pin connector on middle above of the rear panel from the top Ist RJ45 1 Connect to RJ45 plug wiring 1 2nd RJ45 2 Connect to RJ45 plug wiring 2 3rd RJ45 3 Connect to RJ45 plug wiring 3 4th RJ45 6 Connect to RJ45 plug wiring 6 Tie up together J12 Pin connector on middle below of the rear panel from the top Ist WDO Connect to Weigand out WDO Tie up 7 Installation 2nd WDI Connect to Weigand out WDI together 3rd GND Connect to Weigand out GND 4th RXD Connect to RS232 RXD Tie up 5th TXD Connect to RS232 TXD together 6th GND Connect to RS232 GND 7th 485A Connect to RS485A Tie up 8th 485B Connect to RS485B together J17 7Pin connector on right side below of the rear panel from the top Ist Bell Connect to Cable Bell Tie up 2nd Bell Connect to Cable Bell together 3rd BEEP Spare 4th GLED Spare Sth RLED Spare 6th INWDO Connectto Weigand input Tie up 7th INWDI Connect to Weigand input together 3 2 1 Door sensor connection The door sensor is used to detect the door open close state the terminal can monitor if the door has been unauthorized open through the door sensor at this time it can output a alarm signal moreover the terminal can trigger prompt warning if after surpassing a timed period the door still open 2 4 TFT Installa
5. Some users finger prints sometimes can t be verified Cause The fingerprint quality is poor Measure You d better select fine fingerprint less crinkle no desquamation clear image when enroll fingerprint make your finger touch fingerprint sensor with larger area a comparable test should be made after enrollment we suggest you enroll more fingerprints By the way our device supports 1 1 match method and password identified function you could choose one of them 31 Trouble Shooting Appendix How to configure the Wi Fi function for the terminal Stepl Before configuration The terminal serve as a station in the wireless network before the terminal apply to Network another physical component of that 802 11 network consist Distribution system Access Point Wireless Medium must exist You must know the ESSID name of network of local network you want to connect to Step2 Operation step Step 1 Copy the file WiFiConfigure that is along with the product provided by the manufacturer in the PC Step 2 Connect the terminal fingerprint machine with the PC over the Ethernet or RS 232 Step 3 Double click ZKMACUpdata to open this file the following windowing appear 32 2 4TFT Installation Instruction V1 1 1 onfigTool E Wireless End Active Disable Wireless Network ID SSID a Wireless Model Infrastructrue Model x Authentication Type OPEN
6. sometime it is called whips Wiring standard Pin Color Pin Wiring standard TX 1 lt white orange gt 1 TX TX 2 lt Orange gt 2 TX RX 3 lt white green gt 3 RX 4 lt Blue 4 5 lt Blue white gt 5 RX 6 lt Green gt 6 RX 7 lt White brown gt 7 8 lt Brown gt 8 En Installation 3 2 6 RS232 connection The definition of PC connection with fingerprint machine PC Serial Port Fingerprint machine serial port J12 Pin2 Rxd Pin5 Txd Pin3 Txd Pin4 Rxd Pin5 Gnd Pin6 Gnd 3 2 7 RS485 connection RS 485 systems using a bus structure configuration connect the driver to the receiver The transmission line is made by a group of pair twisted cable Each transmitted signal has a pair of conductors consisting of inverted and non inverted signal lines The inverted line is generally indicated by the index A or with the non inverted line designated 18 2 4 TFT Installation Instruction V1 1 1 as B or The receiver simply evaluates the difference between the two lines so that common mode noise on the transmission line will not result in a falsifying of the actual signal however on the line may be produced a difference mode disturbing In order to eliminate this disturbance traditional RS485 networks require a 12Q terminal resistor to be installed at the end of the bus cables based on the physical layout of the pair twist
7. anther one is RS 232 If you select TCP IP here the IP and Port value must to be assigned its value is same with one in the communication option of the fingerprint machine Set the option Ethernet in the fingerprint machine to Yes 36 2 4TFT Installation Instruction V1 1 1 If you selectRS232 must configure these parameter DevicelD COMPort Baud rate same with one in the communication option of the fingerprint machine Step9 Configure the wireless Network IP address Click configMchine this button the following menu will pop up ConfigMachine fa ea Config IP Addr IP Address OF 70 cd _ 70 Subnet Mask oO s G 2 0 g Default Gateway O s 06 gg DE x 50 If there is the DHCP function in the 802 11 network Distribution system you may choose DHCP press OK to exit Otherwise full the IP Address Subnet Mask blank with the correct figure press OK to exit to main interface After all setting for wireless network is completed single click SETbutton on the MODEMConfigTool interface the prompt in working will appear on the fingerprint machine After configure successfully the corresponding message will inform you click OK to close the message 37 Trouble Shooting Be sure to shut down and restart the machine so the configureation change take effect Step10 View the fingerprint machine Wireless Setting You can view the fingerprint machine Wirele
8. effect the door become a passage mode Lost control but security is that the power supply cut off the door will be locked automatically do not permit external personal to come in but permit internal personal go out the door is not to be unlocked until the system power supply is in gear Make sure that the door of lost control but security will be installed in the area which needs to be protected through fair and foul One representative application of lost control but security is to use electrical lock if the power supply break off the external personal is not able to open the door but the internal person can open the by manual operation The working power of the fingerprint access control terminal is DC12V and the working current is approximate 400mA If the working power of the lock is DC12V while its working current is 1000mA much lower than the current of fingerprint machine s power it is allowed to fingerprint machine and lock work together by one power supply In the following three cases we recommend that fingerprint machine and lock be powered separately 1 The working voltage of the lock is DC12V but the current difference of the fingerprint machine and the lock doesn t exceed 1A 12 2 4 TFT Installation Instruction V1 1 1 2 The lock voltage is not DC12V 3 The distance between lock and fingerprint machine is too far NO LOCK DC12V 13 Installation NC2 COM
9. incorrect installation may cause the unit damage Although we could do our best to offer you service the neglect to the file could cause unwanted cost for you 1 Before installation please make sure the power is cut off because it is very dangerous if the power is on The short circuit of power cable may cause the core parts damage 2 All exposed part of connection wire end can not be exceeded 5mm to prevent the bared wire accidental connection which leads to machine break down And also suggest using different colour cable to connect 3 In the place where the static is strong or in winter please connect the grounding firstly in order to prevent the instant mass static damage the machine 4 Connect power supply with device in the last for the wiring connection If you find any unusual thing occur please firstly cut off the power then go to examine Keep in mind wiring operation under power on will lead to machine sudden damage we are not liable for damages and trouble due to such operation 5 The height to mount device is about 1 4 1 5 meter After installation please take off protection film on the fingerprint sensor to get best recognize result 1 Before Installation 6 After installation finish when go to test the exit door button please keep a personal in the outside because sometimes the accidental issue can bring on you are not able to go outside 7 Our equipment offer an automatically function please after the
10. installing finish Run the auto test function to confirm the installation finish In order to guarantee machine run for long time we set an auto sleep and wake up function in the exit factory please carefully examine this function normally setting before using 8 We recommend using above the 12V 3A direct current supply for ZK software s access control device electricity lock better to powered by 12VDC and no more than 1 5 A electric current At this time the electric current of supply should be abovelA than lock power If the parameter of lock power surpasses this scope please connect technical personnel If the power had not met above requests it possibly causes to be unable normally to drive the electricity lock even damage the device 9 Before device to be connected please read and always follow Quick connect Guide closely Because the wrong wiring will cause the core block and sensor to burn out insult in device to break down at this cause ZK Software is not liable for any damages and trouble 10 If the space between power adapters and device is too long please do not use the twisted pair or other type ferrules for the power wire When the power wire is choused you should consider attenuation of voltage which has passed long distance transfer 11 Please use specialized RS485 cable and the RS232 485 converter with power to hookup the network the bus structure apply to connect with each device When a long cable is used to tra
11. 2 NO2 NC LOCK 12V DC12V NC 2 COM 2 Na LOCK pt No2 0 FR 107 NCI CI COMI NOL 1 Lock Power BUT GND SES GND 12V DC12V 14 2 4 TFT Installation Instruction V1 1 1 Yo NC2 COM 2 bo u NO 2 NC 1 Lock Power COM 1 NO 1 NO LOCK BUT FR 107 GND SES E VA FT p nni ip CH pi FV YY 4 3 2 5 Ethernet connection The terminal provide two ways connect Ethernet Ms DE I Connector 4 mal EJ J 1 the terminal connects with PC through cross cable 15 Installation IP 192 168 1 201 Mask 255 255 255 0 IP 192 168 1 101 Mask 255 255 255 0 2 the terminal connects with PC through network and HUB to create a local network Switch E e 8 6 RJ45 qa 3 RJ45 plug wiring diagrams for Ethernet a RJ45 plug standard 16 2 4 TFT Installation Instruction V1 1 1 TOP 1 8 FRONT m 18 b Ethernet 10 100Base T Crossover Cable mostly apply to HUB and Switch or directly connect two Ethernet terminals not through HUB fully support 10Base T and 100Base TX Plugl Pin Pin Plug 2 TX 1 lt gt 3 RX TX 2 lt gt 6 RX RX 3 lt 1 TX RX 6 lt gt 2 TX c Ethernet 10 100Base T Straight Thru Cable Support 10Base T and 100Base TX apply to connect with network card and HUB or network outlet
12. 2 4 TFT Installation Instruction Version 1 1 1 Date June 2010 a TEN About This Manual This document describes the 2 4 TFT installation guide and wiring instruction About this Guide The User guide is designed to provide information to install the 2 4TFT for operation and configuration please refer to the corresponding user s manual Not all function these guides introduce available in combination all is option About your machine function please consult our company technical personnel or the sales personnel Information in this document is subject to change without notice 2 4 TFT Installation Instruction V1 1 1 Contents I Befote Mstalliigi i a sasssa sbr aa E a ESE a 1 1 1 Notice about installing renn 1 2 System Configuration 3 2 1The illustration of system construction in 3 2 2 The sketch map of communication 4 3 Installationi n aa saka a ska BR at ad SRA sal 5 3 1 Fix Mounting Plate eeen di 3 2 Connect with peripheral equipment eeen 6 3 2 1 Door sensor connection ii 8 3 2 2 Exit button connection i 9 3 2 3 Alarm connection 9 3 2 4 Door lock connection 10 3 2 5 Ethernet connection terra 15 3 2 6 RS232 connection
13. always shows Please try again on display Cause For long time used surface of fingerprint sensor becomes dirty or there are some scratches on it the device takes it as a fingerprint and does verification Fingerprint connection cable of fingerprint sensor is loosed Chip on board is broken Measure Under such situation you can scotch tape to adhibit the dirt Need to contact suppler and ask for repair use Startup bar and can t enter menu cycles Cause Fingerprint connection cable of fingerprint sensor insert improperly Fingerprint sensor broke down Chip on board is broken Measure Please take out the Fingerprint 30 2 4TFT Installation Instruction V1 1 1 connection cable from slot of fingerprint sensor plug it again It need to contact suppler to repair The time display as 00 00 restarting after Cause The clock battery is broke down Measure Contact the reseller to replace a battery The fingerprint sensor light is off Cause Fingerprint connection cable of fingerprint sensor connection is broken fingerprint sensor broke down Measure Please take out the FFC from slot of fingerprint sensor plug it again Contact suppler ask for repair keystroke and press finger without sound Cause Trouble in the buzzer loud speaker or circuit Measure Need to replace the buzzer and loudspeaker
14. anage gt User Enroll gt Fingerprint Enroll Enroll a fingerprint and use the fingerprint to test access control system and door lock if there is no any problem Please delete this enrolled fingerprint 24 2 4TFT Installation Instruction V1 1 1 5 Others 5 1 Reset Due to operation error or other accidence which leads the machine not to work you can restart machine through reset key take a small tool which diameter is no more than 2mm find reset mark of res on the left small hole on the bottom of device see following figure Use the tool plug into the hole refer to the picture on right then plug out The machine is able to restart Reset 5 2 Anti dismantle button Anti dismantle button is on middle of device whose function is realized by back cover pressing the anti dismantle button When the device is being dismantled it will send a alarm signal through the terminal 25 Others 5 3 Wireless doorbell Put the doorbell in the proper place press the doorbell key on the device please see red circle mark after the doorbell receive a signal it will ring Bell Note the doorbell is a wireless so the distance from device to doorbell can not be too far it will impact the receiver of doorbell signal if there is shield barrier 5 4 U flash disk using there is a mini port of USB please see figure circle on the left Use USB converter to change mini port into standard USB por
15. ed cables In the normal condition the resistor is not installed only if the bus is extended to over 100 meters the termination must be connected with a terminal resistor The define of terminal connection Terminal J12 Function Pin7 485A RS 485 communication Pin8 485B RS 485 communication sa gt NS 485A 4858 SS a RS485 Bus RS485 e Converter 19 Installation 3 2 8 Wiegand output connection The terminal provides standard Wiegend 26 output which can be connected to most of access controllers like the way of connecting with a ID reader or password keyboard The distance from the controller to device can not be more than 15 meter if the signal must be transferred much further or there is a strong interference around please adopt a wiegand signal amplifier Mote no matter the device is powered by access controller or not the ground ports of them have to be properly together to ensure the weigand transfer reliable Terminal J12 Function Pinl1 WD0 Output wiegand data 0 signal Pin2 WDI1 Output wiegand data 1 signal Pin3 GND Ground Wbo DATAO 20 2 4 TFT Installation Instruction V1 1 1 3 2 9 Connect with external Weigend reader Access control device whit the Weigand input function is able to connect with card reader which is located in outdoor or indoor control the door by the controller together the cable which between access controlle
16. electric lock It is better to use electric drop bolt for the two direction opening glass door both open to inside or outside direction for the single opening wood door in company internal we recommend to use magnetic lock the magnetic lock also be called as electric magnetic lock The magnetic lock is more reliable than the electric drop bolt but the electric drop bolt is much safer than the magnetic lock In the small living community it is better to use electric 10 2 4 TFT Installation Instruction V1 1 1 drop bolt and magnetic force lock The electric control lock gives out higher noise the electric control lock is commonly used to building communication Now there is a soundless electric control lock which is able to be applied Please pay attention the lock is made of iron and easy rust so you must beware of not exposing it to water or harsh condition there are some other electric locks available we don t recommend you to use them Connect with electric lock Input terminal of release door button Button GND The input port of release door button accepts the signal which come from normally opened contact to indicate that somebody want to go out the input equipment such as action detector press sensitivity floor board or exit door button all serve as source to send signal if nobody send out request to want to go out the input keep disconnection if somebody want to go out they trigger release door bu
17. nsfer signal it is need to connect a matching resistance to receiver and its value is 1200 12 Other not details items please see also the user handbook the operating instructions and the appendix and so on 2 4 TFT Installation Instruction V1 1 1 2 System Configuration 2 1The illustration of system construction RSZQIZASABS Convertor i k Door sensor zE il Card Release reader button System Configuration 2 2 The sketch map of communication Fingerprint machine directly connects with PC through RS232 or TCP IP TCP IP or RS232 Switch TCP IP 000 TCP IP TCP IP 2 4 TFT Installation Instruction V1 1 1 3 Installation 3 1 Fix Mounting Plate Take out a fingerprint machine dismantle the screw between machine body and mounting plate until it is out see figure 1 Carefully take up the bottom of mounting plate see figure 2 push it up see figure 3 then take away the mounting plate Determine the position of mounting plate on the wall The fingerprint machine should be mounted on the external wall of the door approximately 1400mm from the ground to the unit bottom After the position is determined you could drill a hole 18mm 20mm for cable out see below figure shadowed part Make the hole of mounting plate meet the drilled hole on the wall Use the screw to fix it on the wall for the details please see following figure a b c d After installati
18. on please make sure the mounting plate is reliable fasten not loosed aS vo Installation 3 2 Connect with peripheral equipment Caution Do not to connect peripheral equipment before the power of the device is cut down otherwise it is possible to damage the device badly Please follow instruction to connect peripheral equipment Door sensor connection Exit button connection Alarm connection Door lock connection Ethernet connection RS232 connection RS485 connection Wiegand output connection 000608000 Power connection ir uo B a n a 6 a a 3 oa bai dg ca bo ta 2 4 TFT Installation Instruction V1 1 1 Table 1 the definition of the Pin of the terminal connector J7 9pin connector on left side above of the rear panel from the top Ist NC2 Connect to Alarm NC terminal Tie up 2nd COM2 Connect to Alarm COM terminal together 3rd NO2 Connect to Alarm NO terminal 4th NCI Connect to Lock NC terminal Tie up 5th COMI Connect to Lock COM terminal together 6th NOI Connect to Lock NO terminal 7th Button Connect to Release button Tie up 8th GND For Door sensor and release button together 9th Sensor Connect to Door sensor J1 2Pin connector on left side below of the rear panel from the top Ist GND Connect to Power GND 2nd 12V Connect to Power 12v Tie up together J2
19. r and external card reader is no more than 90 meter 3 2 10 Power connection This device is powered by 12VDC Its current is approximately 50mA in the ready work status and 400mA in the work status The power is conducted along with the terminal you can use the 12V 4A supply adapter which is provided along with the device The detail about connection is as follow Terminal J1 Function Pinl GND Power negative Pin2 PWR Power positive The following figure is an example which takes a provided power adapter to connect to the terminal 231 Installation pecceoey 00000 ee ei Nepean x P Power 2 4 TFT Installation Instruction V1 1 1 3 3 Fastening fingerprint machine Confirm all connection plugs correctly Align back iron plate of fingerprint machine body to mounting plate properly and push it up see figurel then push device backward see figure 2 Turn and tie up the screw bottom After finishing installation make ensure the body of device is fixed tightly 23 Test and examine after installation 4 Test and examine after installation After all system installation finished make a test and examine prior to power on inspect whether the lock driver is OK or not for more details please see User Guide and Software Manual the green LED begins to glitter after power up enter menu gt Option gt Auto test enter menu gt User m
20. ss Setting to get the information of the wireless network communication Power on the Fingerprint Machine press menu gt System Info gt Dev Info gt wirlesscard gt rausb0 38
21. t see following figure USB can be used to upload and download data by U disk can be connected with U are U fingerprint sensor as an external fingerprint sensor 5 5 Built in EM card reader Optional Built in a contact less EM card reader module the distance of flashing 26 2 4TFT Installation Instruction V1 1 1 card is 5 10 cm it completely supports the thick card 1 88mm middle card 1 05mm and thin card 0 88mm whose operating frequency is at 125 KHZ the card area as following illustration 5 6 Built in MIFARE card reader Optional Contain a contact less MIFARE card reader module the distance to detect card is 5 10cm it completely supports MIFARE cards that provide operating frequency 13 56MHZ communication speed 106KBPS the card area is as following illustration 5 7 Built in HID Card reader Optional Built in a contact less HID card reader module the readable range is 5 10cm it support HID card at operating frequency 125KHZ the card area is as following illustration A RF area 27 Others 5 8 Cable doorbell Optional There is a key which is remarkas icon A on the keypad this key is used for doorbell Put the doorbell in the proper place press the doorbell key on the device please see circle marked after the doorbell receive a signal it will ring Note Because the terminal and key our provided is used for cable doorbell must join the power into the electric round
22. tion Instruction V1 1 1 3 2 2 Exit button connection The exit button is installed for in door operation When the switch of the button is close the door will open The distance is approximately 1400mm from ground to exit button bottom Make sure that the exit button position is to align correct upright and the connection is accurate and reliable Unused exposed end of cable should be cut off and use insulating tape to wrap it Pay attention to electromagnetic disturbance For example The light switch the computer and so on 3 2 3 Alarm connection the terminal alarm output is a switch signal it is able to connect with simple alarm by serial circuit it also apply to top grade alarm and monitor system as a trigger signal this machine alarm function only support 12 VDC Warner Installation AC220V 24V AC relay 3 2 4 Door lock connection The way of installing door lock depends on the type of lock and local condition Internal resistor which comes from long distance transfer should be taken into consideration when selecting the cable of electric power The door lock should be installed reliable and stable Ensure the wiring is correct For the strike lock and electromagnetic lock you should pay attention to positive and negative terminal connection The unused bare end of wire should be cut off and use insulating tape to wrap it The delay time of strike lock is adjustable according to different conditions Select
23. tton the circuit is closed Produce state change the controller responded to the request unlock and permit door serve as passage mode Note 1 the process of performance to unlock door is control by relay when you install door lock there are two thing you must think about safety and security in other words do you want which result that is if lose control of this door the door is still in safety lost control but safety or if lose control of this door the door still is security lost control but security 2 When the Access Control System connected with Electric lock to prevent the self inductance EMF to affect the access control system you need to parallel one FR107 diode do not reverse the polarity Please use the equipped diode in the package 11 Installation Lost control but safety is that the power supply cut off maybe the power supply is cut or the controller lose control of itself the door will be open automatically and permit everybody freely to pass in and out the door is not ability to be closed until the system power on these type of doors are installed in the protective area which ensure everybody is able to pass in and out One representative application of lost control but safety is to use electromagnetism lock under normal power supply the door is controlled by the controller once the power supply break off the electromagnetism lock will lose magnetism and does not take
24. z Encrypt Type NONE v r WEP Password Length 64 bit 104 24 10 hexadecimal digits Password 1 password 2 C password 3 g password dC Password Iuput 8 and 64 characters long for ASCII or 8 and 64 characters 0 9 a f A F for hex Connection parameter TCP IP RS232 ees 192 2168 201 ee DeviceID l COMPort CON Port 4370 Baud rate 57600 Conf igMachine Vi Set Step 3 Activate the software There are two options Active Active Disable Disable on the interface for wireless End station the two options must to be set down If you select the Active item this wireless end will be activated you can configure the AP Access Point of 802 11 networks If you select the Disable this wireless end will be invalid you can set the connection way of the fingerprint machine and its 33 Trouble Shooting configuration of IP address Step4 Confirm Network ID Full the blank of local wireless Network ID you want to connect with any character or figure capital letter and small letter is different Note must fulfill the blank that is marked with Step5 Determine Network model there are two option Infrastructure Model and Ad hoc Model shown as following figure e n i A t Lai P n NI sf PA 1 x n A xs aie 2 I ni