Home

FA-LTBQ75M

image

Contents

1. Connection example Manual pulse generator Input signal 2 When the QD75MH connection B E o eo gt EJ ES Ro m3 Ed Eq e 2 STOP 1 RLS PULSER B PULSER B Connection example Manual pulse Input signal generator 3 When the QD77MS connection TB1 TB2 10 1 213 4 5 16 7 8 9 1011 i213f4ii5lt6 Q miulla es sSi85 sEg Cle lw LLI exl NI I N esse EI ES 1 STOP 2 D0G PULSER B PULSER B PULSER A PULSER A PB oy P5 SG SG Connection O O O O example g gt s Manual pulse Input signal generator 8 APPLICABLE CRIMPING TERMINALS Round Y MK Applicable Bare crimping Insulated crimping Bare crimping Insulated crimping wire size terminal terminal terminal terminal 1 25Y 3 TG 41 25Y 3 R1 25 3N TG 1 25 3N 1 25Y 3N TG 1 25Y 3N o 0 3 1 25mm Nichifu Co Ltd R1 25 3 5N TGj 1 25 3 5N 1 25Y 3L TG 11 25Y 3L NTM 1 25Y 3 5 TG 1 25Y 3 5 2Y 3 TG 2Y 3 1 25 2 0mm R2 3N TG 2 3N 2Y 3 5S TG 2Y 3 5S 1 25 B3A 1 25 C3A V1 25 B3A 0 3 1 25mm4 1 25 MS3 V1 25 MS3 Japan Solderless 1 25 N3A V1 25 N3A Terminal Co Ltd 1 25 C3 5A 2 N3A um 1 25 2 0mm 2 MS3 V2 MS3 V2 N3A 2 M3A VD1 25 3L VDAV1 25 3L R1 25 3ML RAV1 25 3ML 0 3 1 25mm VD1 25 3 5SS VDAV1 25 3 5SS R1 25 3 5SL_ RAP1 25 3ML Nippon Tanshi VD1 2
2. fault occurs in the external power supply or the programmable controller this product Failure to do so may result in an accident due to an incorrect output or malfunction 1 Configure external safety circuits such as an emergency stop circuit protection circuit and protective interlock circuit for forward reverse operation or upper lower limit positioning Configure a circuit so that the programmable controller is turned on first and then the external power supply If the external power supply is turned on first an accident may occur due to an incorrect output or malfunction Design Precautions Do not install the control lines or communication cables together with the main circuit lines or power cables Keep a distance of 100mm 3 94 inches or more between them Failure to do so may result in malfunction due to noise Installation Precautions Q Shut off the external power supply all phases before installation Failure to do so may result in electric shock Use the programmable controller in an environment that meets the general specifications in this User s Manual Failure to do so may result in electric shock fire malfunction or damage to or deterioration of the product Securely fix the module with a DIN rail or mounting screws Incorrect mounting may cause malfunction failure or drop of the module When using this product in an environment of frequent vibrations fix the module with a screw Tighten
3. no condensation humidity Storage ambient 5 to 95 RH no condensation humidity 0 to 55 C JIS B 3502 IEC61131 2 oom 10 times each in X Y and Z axis directions Compliant standards Under 10 to 57Hz Vibration resistance jntermittent Pra aes 57 to 150Hz 9 8m s 1G Under 10 to 57Hz 0 035mm continuous vibration 57 to 150Hz 4 9m s 0 5G NN Hic eu EE Conforms to JIS B 3502 and IEC61131 2 147m s 15G 3 times each in X Y and Z axis directions Operating There should be no corrosive gases atmosphere Operating 2 000 altitude C POI eee Installation location Inside control panel Overvoltage category 2 II or lower Pollution level 2 or lower 1 Do not use or store in a pressurized environment greater than the atmospheric pressure at an altitude of Om 2 Indicates how an assumption has been made on the point at which the devices are connected from the public power grid to the machinery and equipment inside the facilities 3 This is a guideline indicating the extent to which conducting substances are found in the environment in which the devices are used 3 PERFORMANCE SPECIFICATIONS a eer von FA LTBQ75M Number of supported axes 2 axes 2 units used for 4 axes Rated voltage 24 VDC CLASS 2 Input Rated current signals Used voltage 4 5 to 26 4 VDC CLASS 2 range M3 screws 7 62 mm pitch Terminal vem screw Mounting screws 4 CONNEC
4. 5 3 5S VDAV1 25 3 5S o To s IwD2 3S Co Ltd TN TR RAV2 3SL I VDAV2 3 5SS NTK tae ns RAP2 3SL A VDAV2 3 5S VD2 3 5S Q Size of crimping terminal Round bare crimping termainal Round insulated crimping terminal Unit mm Y bare crimping terminal Y insulated crimping terminal oize of crimping terminal Q Terminal trapezoid Unit mm 7 62 7 10 9 Gratis Warranty Terms and Gratis Warranty Range If any fault or defect hereinafter referred to as Failure attributable to Mitsubishi Electric should occur within the gratis warranty period Mitsubishi Electric shall replace the product free of charge via the distributor from whom you made your purchase eGratis Warranty Period The gratis warranty period of this product shall be one 1 year from the date of purchase or delivery to the designated place eGratis Warranty Range 1 The gratis warranty range shall be limited to normal use based on the usage conditions methods and environment etc defined by the terms and precautions etc given in the instruction manual user s manual and caution labels on the product 2 In the following cases a repair fee shall be applied even if within the gratis warranty period 1 Failure resulting from inappropriate storage or handling carelessness or negligence by the user or Failure caused by the user s hardware or software design 2 Failure caused by unapproved modifications etc to the prod
5. Positioning Module Terminal Block Conversion Module FA LTBQ75M User s Manual Thank you for purchasing FA Goods product Before using please read this User s Manual and the relevant manuals carefully to ensure correct use s MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED SAFETY PRECAUTIONS Always read these precautions prior to use Before using this product please read this User s Manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly The precautions presented in this manual are concerned with this product only For programmable controller system safety precautions refer to the User s Manual of the programmable controller to be used In this manual the safety precautions are classified into two levels WARNING and N CAUTION Indicates that incorrect handling may cause hazardous N WARNING conditions resulting in death or severe injury N CAUTION Indicates that incorrect handling may cause hazardous conditions resulting in minor or moderate injury or property damage Under some circumstances failure to observe the precautions given under A N CAUTION may lead to serious consequences Observe the precautions of both levels because they are important for personal and system safety Design Precautions Configure safety circuits external to the programmable controller to ensure that the entire system operates safely even when a
6. TED TARGET MODEL PLC MODULE CONNECTION CABLE PLC Module Model Cable Model between Module Model Connected Devices PLC Module QD75M1 QD75M2 QD75M4 MELSEC Q QD75MH1 External devices Series QD75MH2 FA CBL Q7 FA LTBQ75M Connection signals connector type QD75MH4 For terminal block conversion QD77MS2 Note 1 Note 2 QD77MS4 Note 1 Note 2 QD77MS16 Note 1 Note 2 Note 1 The following signals to connecting differential output type of manual pulse generator Incremental synchronous encoder will not use QD77MS HAH HAL HBH HBL Note 2 Units shall use to be replaced with signal names as the following FA LTBQ75M QD77MS Terminal names Signal names meme 0 L mem 0m 5 EXTERNAL DIMENSIONS Unit mm 2 4 5x5 1 elongate hole DIN rail center 6 INSTALLATION METHOD Connection example of PLC positioning module and servo amplifier When connected to Mitsubishi Electric Corporation MR J4 Series Attach the terminal block securely to the PLC module with attachment screws Programmable controller module QD75M1 other Connection cable between positioning module and conversion module FA CBL Q 7 Insert the connector to the back and then fully secure the connector with a clip Manual pulsar all external signals 7 EXTERNAL CONNECTION EXAMPLE Note The Manual pulse generator please use HR HDPO1 manufactured by Mitsubishi Corporation 1 When the QD75M connection TB2
7. nction due to noise Place the cables in a duct or clamp them If not dangling cables may swing or inadvertently be pulled resulting in damage to the module or cables or malfunction due to poor connection Tighten the terminal screw within the specified torque range Undertightening can cause short circuit fire or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction Tighten the connector screws within the specified torque range Undertightening can cause short circuit fire or malfunction Overtightening can damage the screw and or module resulting in drop short circuit fire or malfunction Install the connector to the module securely Failure to do so may cause malfunction When disconnecting the cable from the module do not pull the cable by the cable part For a cable with connector hold the connector by hand and pull it out For a cable connected to a terminal block loosen the terminal block screws first before removing the cable Failure to do so may result in malfunction and damage to the module or cable Before connecting the cables check the type of interface to be connected Connecting or erroneous wiring to the wrong interface may cause failure to the module and external devices Prevent foreign matter such as dust or wire chips from entering the module Such foreign matter can cause a fire failure or malfunction This product must be installed to c
8. ontrol panels Connect the main power supply to this product in the control panel through a relay terminal block Wiring and replacement of a this product must be performed by qualified service personnel who is familiar with protection against electric shock When connecting programmable controller check that the product configuration are correct The modules may be failure or malfunction if the configuration is incorrect Use it with power doesn t join the connector of this product Failure or disconnection may cause malfunction Startup and Maintenance Precautions Do not touch any terminal while power is on Doing so will cause electric shock or malfunction Shut off the external power supply for the system in all phases before cleaning the module or retightening the terminal screws connector screws or module fixing screws Failure to do so may result in electric shock or cause the module to fail or malfunction Undertightening can cause drop of the screw short circuit or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction Startup and Maintenance Precautions N CAUTION Do not disassemble or modify the modules Doing so may cause failure malfunction injury or a fire Use any radio communication device such as a cellular phone or PHS Personal Handy phone System more than 25cm 9 85 inches away in all directions from the programmable controller this prod
9. the screw within the specified torque range Undertightening can cause drop of the screw short circuit or malfunction Overtightening can damage the screw and or module resulting in drop short circuit or malfunction Shut off the external power supply for the system in all phases before mounting or removing the module Failure to do so may result in damage to malfunction or failure of the product Do not directly touch any conductive parts and electronic components of this product Doing so can cause malfunction or failure of the product Shut off the external power supply for the system in all phases before installation and wiring After wiring attach the included terminal cover to the module before turning it on for operation Failure to do so may result in electric shock Wiring Precautions Use applicable solderless terminals and tighten them within the specified torque range If any spade solderless terminal is used it may be disconnected when the terminal screw comes loose resulting in failure Check the rated voltage and terminal layout before wiring to the module and connect the cables correctly Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure Do not install the control lines or communication cables together with the main circuit lines or power cables Keep a distance of 100mm 3 94 inches or more between them Failure to do so may result in malfu
10. ts or compensation for other work carried out by the user 11 N FOR YOUR SAFETY This product has been manufactured as a general purpose product for general industry applications etc The product is not intended for use in devices or systems used under conditions in which human life could be greatly affected When considering application of this product to special applications such as nuclear power electrical power aerospace medical or manned transport devices or systems contact our sales service desk Although this product was manufactured under a strict quality management system the product shall be systematically provided with backup and fail safe functions when applied to equipment that may lead to a major accident or damage in the unlikely event any failure or defect should occur in the product s MITSUBISHI ELECTRIC ENGINEERING COMPANY LIMITED 1 13 5 Kudankita Chiyoda ku Tokyo Japan 102 0073 Homepage URL http www mee co ip During product use be sure to ensure safety in the unlikely event failure occurs Mitsubishi Electric Engineering assumes no responsibility whatsoever for any secondary damage caused by the failure of this product o0D FA9010 029 A Information such as specifications is subject to change without notice Developed March 2014 12
11. uct Failure to do so may cause malfunction Shut off the external power supply for the system in all phases before mounting or removing the module Failure to do so may cause the module to fail or malfunction or damage After the first use of the product do not mount remove the module and the cable more than 50 times IEC 61131 2 compliant respectively Exceeding the limit of 50 times may cause malfunction Startup and maintenance of a control panel must be performed by qualified maintenance personnel with knowledge of protection against electric shock Lock the control panel so that only qualified maintenance personnel can operate it Before handling the module touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause the module to fail or malfunction Disposal Precautions N CAUTION When disposing of this product treat it as industrial waste Transportation Precautions The shock that exceeds the range of the general specification during transportation must avoid this product for the precision instrument Doing so results in the risk of failure 1 INTRODUCTION This User s Manual describes the specifications and so on for terminal block conversion modules used in combination with Mitsubishi Electric Corporation positioning modules 2 GENERAL SPECIFICATIONS Operating Surrounding air temperature Storage ambient A Operating ambient 5 to 95 RH
12. uct by the user 3 Failure that could have been avoided if when the Mitsubishi Electric Engineering product was assembled into the user s device safeguards defined by legal regulations applicable to the user s device or functions or structures considered standard by the industry had been provided 4 Failure recognized as preventable if the consumed products specified in instruction manuals etc were normally maintained or replaced 5 Replacement of consumable parts relays etc 6 Failure caused by external factors beyond anyone s control such as fires or abnormal voltage and Failure caused by Force Majeure such as earthquakes lightning or wind and water damage 7 Failure caused by reasons unpredictable by scientific technology standards at the time of shipment from Mitsubishi Electric Engineering 8 Any other failure not attributable to Mitsubishi Electric Engineering or found by the user to not be attributable to Mitsubishi Electric Engineering 10 Exclusion of Opportunity Loss and Secondary Loss from Warranty Liability Regardless of the gratis warranty period MEE shall not be liable for compensation for damages arising from causes not attributable to MEE opportunity losses or lost profits incurred by the user due to Failures of MEE products damages or secondary damages arising from special circumstances whether foreseen or unforeseen by MEE compensation for accidents compensation for damages to products other than MEE produc