Home

FCC TEST REPORT

image

Contents

1. 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC REGISTRATION NO 90868 16 EUT Photographs REPORT NO E930080 Model No W 8731 Page 20 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 iii T A NY gt a AF Sy k i mT Don BE Page 21 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 ENNE EE Ew e sar ES thas i i HHS aj HUE ing S Jaj fal RE Eho S nn SE 2 d Page 22 of 27 PEP Testing Laboratory 12 3FI No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC REGISTRATION NO 90868 REPORT NO E930080 WINCON 1 Dg es CB Be Page 23 of 27 PEP Testing Laboratory 12 3FI No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC REGISTRATION NO 90868 REPORT NO E930080 PALA SH Ra RHR i lu ia a USL IIETETIETETEETETTEN os Page 24 of 27 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC REGISTRATION NO 90868 REPORT NO E930080 Page 25 of 27 PEP Testing Laboratory 12 3Fl No 27 1 Lane 1
2. Quasi Peak Value Frequency range above 1GHz Detector Quasi Peak Average Value Temperature 26 C Humidity 54 Antenna polarization HORIZONTAL Test distance _10m_ Over Limit Read Antenna Cable Preamp Freq Level Limit Line Level Factor Loss Factor Azimuth Antenna MHz dBuV m dB dBuV m dBuV dB dB dB angle High m 71 883 29 58 9 42 39 00 40 33 8 21 0 84 19 80 112 0 4 0 167 729 27 85 15 65 43 50 34 93 11 25 1 30 19 63 193 0 4 0 206 436 38 25 5 25 43 50 47 06 9 15 1 50 19 46 287 0 4 0 309 770 38 65 7 75 46 40 41 56 14 46 2 01 19 38 58 0 D 516 087 38 77 7 63 46 40 35 19 19 68 2 52 18 62 256 0 d 618 871 37 55 8 85 46 40 32 34 21 74 2 62 19 35 147 0 345 Note 1 Level Read Level Antenna Factor Cable Loss Preamp Factor 2 Over Limit Level Limit Line Page 15 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 Model No W 8731 Frequency range 30MHz to 1GHz Detector Quasi Peak Value Frequency range above 1GHz Detector Quasi Peak Average Value Temperature 26 C Humidity 54 Antenna polarization VERTICAL Test distance 10m Over Limit Read Antenna Cable Preamp Freq Level Limit Line Level Factor Loss Factor Azimuth Antenna MHz dBuV m dB dBuV m dBuV dB dB dB angle High m 48 736 33 38 5 62 39 00 42 57 10 28 0 53 20 00 236 0 1 0 71 883 33 58 5 42 39 00 44 33 8 21 0 84 19 80 179 0 1 0 169 500 30 85
3. 12 65 43 50 37 76 11 43 1 30 19 64 283 0 1 0 309 770 39 64 6 76 46 40 42 55 14 46 2 01 19 38 317 0 255 516 087 38 45 7 95 46 40 34 87 19 68 2 52 18 62 158 0 13 618 871 35 67 10 73 46 40 30 66 21 74 2 62 19 35 63 0 ks Note 1 Level Read Level Antenna Factor Cable Loss Preamp Factor 2 Over Limit Level Limit Line Page 16 of 27 PEP Testing FCC REGISTRATION NO 90868 13 List of Test Equipment Laboratory REPORT NO E930080 Test Mode Instrument Model No Serial No Next Cal Date Cal Interval R amp S Rec ESHS10 830223 008 May 22 2004 1Year ecelver Rolf Heine NNB 4 63TL 98008 May 01 2004 1 Year LISN R amp S IN ESH3 Z5 844982 039 Aug 06 2004 1Year Conduction No 1 Spectrum R3261A 91720076 June 08 2004 1Year Analyzer RF Cable Rg400 N A May 12 2004 1Year i T411 N A June 29 2004 1Year ISN R amp S ne ESVS30 863342 012 May 20 2004 1Year ecelver Schaffner CPA9232 192 May 12 2004 1Year re amplifier COM Power AH 118 ei demai 10095 May 21 2004 2Year Schwarzbeck Radiation VHAP 970 971 OP No 1 PE AOE 30MHz 1GHz 953 954 June 26 2006 3 Year b Signal SMY01 841104 037 Apr 28 2004 1Year enerator RF Cable No 1 N A May 11 2004 1Year EMCO 3142B eee 6MH2 2GH2 9904 1370 Aug 24 2004 1Year Page 17 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO
4. E930080 14 Labelling Requirement A warning label with the following statement shall be permanently attached and conspicuously located on the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this devices must accept any interference received including interference that may cause undesired operation Page 18 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 15 Information to The User The following FCC statement should be declared in a conspicuous location in the user s manual Federal Communications Commission FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Page 19 of 27 PEP Testing Laboratory 12 3Fl No
5. emission test The maximum readings were found by varying the height of antenna and then rotating the turntable Both polarization of antenna horizontal and vertical are measured The effect of varying the position of the interface cables has been investigated to find the configuration that produces maximum emission The highest emissions were also analyzed in details by operating the spectrum analyzer in fixed tuned quasi peak mode to determine the precise amplitude of the emissions Page 6 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 4 Modification s The applicant has been notified and agrees to incorporate the following modification s into all production units please refer to the attached pages in this report A Respectively ground the 9th pin and 37th pin of SACE U21 in parallel using 0 luF capacitors shown as page 22 B Respectively ground two pins of SACE Y2 Y4 and Y5 in parallel using 45PF capacitors shown as page 22 C Respectively ground two pins of SACE YI in parallel using 15PF capacitor shown as page 24 D Respectively arrange parallel connections to SACE C39 C41 C46 C48 C31 and C30 using 0 luF capacitors shown as page 23 E Respectively ground the 3 rd pin 27th pin 43rd pin and 49th pin of SACE U12 in parallel using 0 1uF capacitors shown as page 22 F Respectively ground the 9th pin and 37th pin of SACE U2 in parallel using 0 1uF capacitors sh
6. 2 gt Back Shell Metal Page 8 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 5 Personal Computer PC1 6 Keyboard KBU1 USB 7 DC Power Supply 8 HUB CPU Intel P M600 MHz FCC ID Declaration of Conformity DoC Manufacturer ASUS INC Model Number P2 99 Power Supply Switching Power Cord Non Shielded Detachable 1 8m Data Cable N A FCC ID E5XKB7932MUF0310 Manufacturer BTC Model Number 7932M Power Supply 5Vdc from USB of PC Power Cord N A Data Cable 1 gt Shielded Non detachable 1 6m 2 gt Back Shell Metal Manufacturer AMB Model Number 9306D Manufacturer N A Model Number N A Page 9 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 7 Conducted Disturbance Test 7 1 Conducted Disturbance Emission Limit Frequency Maximum RF Line Voltage dB uV MHz QUASI PEAK A 0 15 0 5 79 3 E ies Remarks In the above table the tighter limit applies at the band edges Page 10 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 8 Radiated Disturbance Test 8 1 Setup of the Test Facilities The equipment under test was setup on the non conductive table in the open field site The table was placed on a remote turntable constructed of a wooden material The top of the table is located 1m above the ground pla
7. 69 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC REGISTRATION NO 90868 REPORT NO E930080 MODEL NO W 8031 Page 26 of 27 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC REGISTRATION NO 90868 REPORT NO E930080 MODEL NO W 8331 Page 27 of 27 VERIFICATION WE HEREBY VERIFY THAT The Equipment Under Test EUT listed below has completed RFI testing by PEP Testing Laboratory and the interference emissions can pass FCC Class A limitations The test report shall not be reproduced except in full without the written app roval of the laboratory The estimate uncertainty of the test result is about 3dB The test result is only effect for the sample as below APPLICANT ICP DAS CO LTD EQUIPMENT Embedded Controller MODEL NO _W 8731 W 8031 W 8331 W 8037 W 8039 W 8337 W 8339 W 8737 W 8739 REPORT NO E930080 C l 4 z FEB 25 2004 M Y TSUI Manager
8. PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 FCC TEST REPORT According to FCC Part15 ClassA EQUIPMENT Embedded Controller MODEL NO gt W 8731 W 8031 W 8331 W 8037 W 8039 W 8337 W 8339 W 8737 W 8739 APPLICANT ICP DAS CO LTD NO 111 KUANGFU N RD HUKOU SHIANG HSINCHU TAIWAN 303 R O C TEST ENGINEER SIMON LIU CHECKED BY HADES HUALNG ISSUED DATE FEB 25 2004 The test result refers exclusively to the test presented test model sample Without the written authorization of the test lab the Test Report may not be copied PEP TESTING LABORATORY 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 Page 1 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 TABLE OF CONTENTS 1 General mmm 4 1 1 General Information 1 2 Place of Measurement 2 Product Information lt s 5 3 EUT Description And Test Methods eee 6 4 Modification s reenter 7 5 Test Software Used gt ttn 7 6 Supporting Devices To Test rrr 8 7 Conducted Disturbance Test rset 10 7 1 Setup of the Test Facilities 8 Radiated Disturbance Test gt T 13 8 1 Setup of the Test Facilities 8 2 Open Test Site Setup Diagram 8 3 Radiated Disturbance Emission Limit 9 Conducted Test Configuration P
9. hoto 13 10 Conducted Emissions Test Data rt 13 11 Radiated Test Configuration Photos rnin 14 12 Radiated Emissions Test Data emme 15 13 List of Test Equipment mm 7 Page 2 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 14 Labelling Requirements inn 18 15 Information To The User 19 16 EUT Photographs assess 20 Page 3 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 1 General 1 1 General Information APPLICANT ICP DAS CO LTD NO 111 KUANGFU N RD HUKOU SHIANG HSINCHU TAIWAN 303 R O C MANUFACTURER ICP DAS CO LTD NO 111 KUANGFU N RD HUKOU SHIANG HSINCHU TAIWAN 303 R O C MEASUREMENT PROCEDURE ANSI C63 4 1992 1 2 Place of Measurement PEP TESTING LABORATORY 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC Registration No 90868 Page 4 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 2 Product Information a EUT Name Embedded Controller b Model No W 8731 c CPU Type Intel SA 1110 d CPU Frequency 206MHz e Crystal Oscillator s 3 6MHz f Chassis Used ABS BC g Port Connector s RJ45 Port x 1 D SUB Port x 1 PS2 Port x 2 USB Port x 1 RS232 Port x 1 h Power Rating DC10V DC30V i Condition of
10. ne The turntable was rotated to obtain the maximum level of radiated emissions from the system containing the EUT for each emissions level investigated 8 2 Open Test Site Setup Diagram 10m PLANE TURN TABLE TO RECEIVER Page 11 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 8 3 Radiated Disturbance Emission Limit Limits for radiated disturbance of Class A ITE at a measuring distance of 10 m Frequency Field Strength MHz dB u V m 30 88 39 0 88 216 43 5 216 960 46 4 960 avove 49 5 NOTES I The lower limit shall apply at the transition frequency 2 Additional provisions may be required for cases where interference occurs Page 12 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 9 Conducted Test Configuration Photo N A 10 Conducted Emissions Test Data Page 13 of 27 PEP Testing Laboratory 12 3Fl No 27 1 Lane 169 Kang Ning St Hsi Chih Taipei Hsien Taiwan R O C TEL 886 2 26922097 FAX 886 2 26956236 FCC REGISTRATION NO 90868 11 Radiated Test Configuration Photos REPORT NO E930080 lt FRONT VIEW gt lt REAR VIEW gt Page 14 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 12 Radiated Emissions Test Data Model No W 8731 Frequency range 30MHz to 1GHz Detector
11. own as page 23 G Respectively ground the 27th pin 43rd pin and 49th pin of SACE Ul in parallel using 0 1pF capacitors shown as page 23 H Spread ground plane beneath PS2 connector shown as page 24 I Interconnect the ground of the 7th pin of SADV J5 and the ground of C9 shown as page 24 5 Test Software Used A PING EXE was the command executed to deliver signals between two PCs during the test Page 7 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 6 Support Equipment Used 1 Keyboard KBS1 PS 2 x 2 FCC ID E5XKB5121WTHO110 Manufacturer BTC Model Number 5121 W Power Supply 5Vdc from PS2 of PC Power Cord N A Data Cable 1 gt Shielded Non detachable 1 6m 2 gt Back Shell Metal 2 Monitor MONI 15 x 2 FCC ID Declaration of Conformity DoC Manufacturer SAMSUNG Model Number 550S Power Supply Switching Power Cord Non Shielded Detachable 1 8m Data Cable 1 gt Shielded Non detachable 1 2m 2 gt Back Shell Metal 3 Modem MOD1 FCC ID IFAXDM1414 Manufacturer ACEEX Model Number 1414 Power Supply Linear 9Vac O P Power Cable Non Shielded Detachable 1 7m Data Cable 1 gt Shielded Detachable Im 2 gt Back Shell Metal 4 Mouse MOUS 1 PS 2 x 2 FCC ID DZL211106 Manufacturer LOGITECH Model Number M S43 Power Supply 5Vdc from PS2 of PC Power Cord N A Data Cable 1 gt Shielded Non detachable 1 8m
12. the EUT Prototype Sample vf Engineering Sample Production Sample j Test Item Receipt Date FEB 18 2004 Page 5 of 27 PEP Testing Laboratory FCC REGISTRATION NO 90868 REPORT NO E930080 3 EUT Description and Test Conclusion The equipment under test EUT is Embedded Controller model W 8731 W 8031 W 8037 W 8039 W 8331 W 8337 W 8339 W 8737 and W 8739 These models have identical electrical design and construction except that they are different in amount of slot and embedded operating system After verifying these models we took the worst case model W 8731 for test The EUT contains one VGA port two PS2 ports one USB port one RJ 45 port one COM port and seven slots DC 10V 30V from any DC power source is required to operate EUT For more detail specifications about the EUT please refer to the user s manual Test method According to the major function designed the EUT configuration was set up by the following steps for test A Install keyboard and mouse to EUT PS 2 ports B Install monitor to EUT VGA port C Install USB keyboard to EUT USB port D Install modem to EUT COM port E Connect EUT RJ 45 port to remote PC off test table All corresponding peripherals to EUT I O ports were set to proceed with test The test was carried out on EUT operational condition and the worst case test result was recorded and provided in this report Conducted emission test N A Radiated