MultiBio 700 Installation Guide

image

Contents

1. 12V I ILock gt 1A And the lock is near to the device A Device does not shares power with the lock A Utock 12V_ ItockS 1A os B Utock 12V C The lock is far apart from the device 1 The system supporst NO LOCK and NC LOCK For example the NO LOCK normally open at power on is connected with NO terminal and the NC LOCK is connected with NC terminal 2 When the Electrical Lock is connected to the Access Cont rol System you need to parallel one FR107 diode equipped in the package to prevent the self inductance EMF affecting the system do not reverse the polarities 5 Connected with Power 4 Connected with other parts Input DC 12V 500mA 50mA standby Door Bell Positive is connected with 12V negative is connected with GND do not reverse the polarities fp x DC12V EXT BUTTON Exit Button Alarm Power Door Sensor Voltage output lt DC 12V for Alarm T device output current Urock lock lock voltage lock current 6 Wiegand Output 7 Wiegand Input The device supports standard Wiegand 26 output The device has the function of Wiegand signal input It s upports to as a reader device it has a very good compatibility connect with an independent card reader They are installed each side of the door to control the lock and access together Access Control 1 Please keep the distance between the d
2. 85 Converter 3 TCP IP Mode A Crossover cable The device and PC connected B Straight cable The device and PC connected to directly LAN WAN through switch Lanswitch IP Address 192 168 1 100 Subnet Mask 255 255 255 0 a gt IP Address 192 168 1 124 Subnet Mask 255 255 255 0 10 Cautions 1 Power cable is connected after all the other wiring If the device is working abnormally please shut down the power first then make the necessary check Kindly reminds you that any hot line work may damage the device and it is not included in the warranty 2 We recommend the 3A 12V DC Power supply Please contact our technical staff for details 3 Please read the terminals description carefully and wiring by rule strictly Any damage caused by improper operations will not under warranty 4 Keep the exposed part of wire less than 5mm to avoid unexpected connection 5 Please connect the GND before all the other wiring especially under the environment to prevent the overlarge instantaneous electrostatic to damage device 6 Do not change the cable type because of long distance between the power and the device 7 Please use specified RS485 wire RS485 active converter and bus type wiring
3. MultiBio 700 Installation Guide Version V1 1 Date Nov 2011 1 Equiment Installation MultiBio 700 Mounting Paper only for your reference 1 Post the mounting template on the 2 Remove the screw on the bottom 3 Take away the back plate wall Drill the holes according to of device the marks on the template holes for screw and wiring 4 Fix the back plate on the wall according to the mounting paper 5 Fix the device to the back plate 2 Structure and Function Fe Access Control System Function 1 If a registered user verified the device will export the signal RS485 TCP IP I woe to unlock the door RS232 RS485 Converter 6 2 Door sensor will detect the on off state If the door is un af E 6 mame kock Senso 3 As the d evice is removed illegally it will output an alarm signal Ne F oy Door Bell External Reader EY 5 External exit button is supported it is convenient to open the Exit Button expected opened or improperly closed the alarm signal 4 digital value will be triggered 4 External card reader is supported oe door inside 6 External door bell is supported O 7 Supports RS485 TCP IP modes to connect with PC One PC can Alarm manage multiple devices K Warning No operating with power on 3 Lock Connection 1 Shares power with the lock Device shares power with the lock Urock
4. evice and Access Control or Card Reader less than 90 meters Please use Wiegand signal extender in long distance or interference environment 2 To keep the stability of Wiegand signal connect the device and the Access Control or Card Reader in same GND in any case Other Functions 1 Manual Reset If the device does not work properly because of misoperation or other abnormality you can use Reset function to restart it Side View Back View Operation Remove the black rubber cap then stick the Reset button hole with a sharp tool the tip diameter less than 2mm 2 Recovery Factory Settings You can use the tamper switch to recovery factory setting such as device number system password IP address RS485 address etc More information please refers to the user manual Operation Press the tamper switch three times after the alarm being triggered 30 seconds but no more than 60 seconds Reset Button Tamper Switch Note The user data won t be cleared 9 Communication There are three modes that the PC software communicate and exchange information with the device RS232 RS485 and TCP IP and the last two mode support remote control Terminals 1 RS232 Mode PC Serial Ports Warning No operating with power on 2 RS485 Mode Re Please use specified RS485 wire RS485 active converter and 485 z i a bus type wiring 485 485 4 Terminals RS485 Bus RS4

Download Pdf Manuals

image

Related Search

Related Contents

Service Manual - Direct Healthcare Services  Usermanual Laserfax 3245 uk  Teclado e Mouse Sem Fio da IBM: Guia do Usuário  取り付け方法説明書(PDF)  Honeywell RTHL3550 Use and Care Manual  Shigella Real Time PCR Kit User Manual For In Vitro  『昭和銀座ジオラマ』 2009 年 4 月 10 日  User Manual - Intermatica  Giga Orion-Lynx User Manual V1.1  

Copyright © All rights reserved.
Failed to retrieve file