Home
fume filtration unit user and installation instructions
Contents
1. Lincat FUME FILTRATION UNIT L3 L4 USER AND INSTALLATION INSTRUCTIONS Dear Customer Thank you for purchasing this Lincat product With correct use and careful maintenance as described in these instructions your Lincat product will give years of trouble free use We produce over 400 different items of catering equipment and our range is constantly being extended and improved Find out more about Lincat products from your local distributor or direct from us 18346 ECN3219 1 CONTENTS GONTENTS ae A EA E e A EE A EOE SAFETY INFORMATION MGMGu Guusscceeee veere renn DELIVERY GHEGKEIST rrini ai industria EL aa alen iiaia hede ieii TECHNICAL SPECIFICATION isicssichacesuatewncestdaiieasiivaenaunhedantartosdsgttnnetoajandiacsans INSTALLATION sGd w sss seeren een reen ennen eres enes OPER AMON BEES a ET E O E eaesauee CLEANING iirst Een EE EA AAi i AA NANN G Seen ere eae ee arene er eer ere ee eee re es ee SPAREPART S rc nea cei et ene i Saree aac A SERVICE INFORMATION sicicc asarsecencniotccensediatans celavdyaedeneiadietesuetbosaeidereiestetare GUARANTEE pa as at ig ae Pecan a See ca cece ceases AN SAFETY INFORMATION To prevent injury to yourself or your staff and to avoid damaging the product please read and follow the safety precautions below before setting up and using the unit e Remove all plastic coatings and clean the unit before use e Ensure that the electrical supply cable is not damaged If it is it must
2. DETAIL A CLEANING Important Take care not to damage the thermostat capillary when cleaning Clean the unit regularly to maintain efficient performance and hygiene Disconnect the unit from the electricity supply and allow to cool before starting to clean Use a mild detergent in hot water and a soft cloth Do not allow excess water to run into the unit Do not use abrasive creams or scourers Burnt on food may be removed using Carb n off or similar cleaner 15346 ECN3219 6 MAINTENANCE The parts listed below can be replaced by the user No other regular maintenance is required Lamp Bulb Ensure that the unit is turned off and unplugged from the mains Replace old bulb Re fit glass cover Filters Ensure that the unit is turned off and unplugged from the mains Release the 2 suitcase latches and open the door Slide filters out of unit and replace with new ones Close and secure door Carefully prise glass cover off using a small flat bladed screwdriver SPARE PARTS Description Part No L3 L4 On Off switch SW66 1 1 Light Switch SW70 1 1 Light Bulb LAO8 2 2 Safety Thermostat TH73 1 1 Centrifugal Fan FA25 2 3 Power Cable Plug amp Lead PL201 1 1 Suitcase Style Latch SU15 2 2 Aluminium Grease Filter FI11 2 3 Charcoal Filter FI13 2 3 Foam Pad Filter Fl15 2 3 1S346 ECN3219 7 SERVICE INFORMATION For help with the installation maintenance and use of y
3. be replaced by Lincat Ltd or by qualified personnel e Always disconnect the unit from the electricity supply before servicing e The unit must be earthed e Do not try to modify this unit e Keep these instructions in a safe place for future reference 18346 ECN3219 2 DELIVERY CHECKLIST Electric fume filtration unit With electrical supply cable and 10A plug User amp installation instructions Guarantee card Aluminium filters L3 x 2 L4 x 3 Carbon filters L3 x 2 L4 x 3 If an item is missing please contact your dealer TECHNICAL SPECIFICATION Model Width i a 77 Power Rating Net weight net INSTALLATION e Remove the protective plastic coating from all metal surfaces e Unlatch the front flap and slide out the filters e Ensure that the wall on which the filtration unit is to be fitted is suitable for supporting the appliance via the masonry plugs e Ensure ample room ventilation with no cross draughts 7 10 air changes per hour e Install the filtration unit so that there is an air space above it with the front lower edge of the canopy about 800mm above the cooking surface The front edge should overlap the cooking area by approximately 100mm e For safety regulations the plug or means of disconnection must always be accessible e Using ano 4 masonry drill drill holes in a suitable wall as shown in Fig 1 for the L4 and Fig 2 for the L3 Insert rawl plugs into holes H
4. ang the unit onto screws in the bottom row of holes and then secure in place by screwing through the fan covers into the top row of holes 15346 ECN3219 3 Fig 1 ia 345 0 gt 345 0 sais 405 0 50 0 14 0 51 0 14 0 10370 2040 3170 eo s o S co Fig 2 715 0 18346 ECN3219 CONNECTING TO THE ELECTRICITY SUPPLY The unit must be earthed Check that the voltage of your electricity supply corresponds to the voltage shown on the serial plate The product is supplied with a 10 amp plug If replacing the plug connect the terminals as follows Green and yellow wire Earth E Blue wire Neutral N Brown wire Live L OPERATION e Plug the unit into the mains supply e Turn the power switch on as indicated in Fig 3 the fans will run until the unit is switched off e To use the lights turn on the light switch as indicated in Fig 3 Figure 3 FRONT VIEW ON OFF SWITCH LIGHT SWITCH 1S346 ECN3219 5 e This unit is fitted with a safety thermostat which will cut power to the fans in the event of a fire To re set the safety thermostat press in the button as indicated in Fig 4 Figure 4 TO RESET SAFETY THERMOSTAT PRESS THIS BUTTON IN
5. our Lincat equipment please contact our service department UK 01522 875520 All service work other than routine cleaning should be carried out by one of our authorised service agents We cannot accept responsibility for work carried out by other persons To ensure your service enquiry is handled as efficiently as possible please tell us Brief details of the problem Product code Type number From serial plate Serial number Lincat reserve the right to carry out any work under warranty during normal working hours ie Monday to Friday 08 30 a m 17 30 p m GUARANTEE This unit carries a comprehensive UK twelve month warranty The guarantee is in addition to and does not diminish your statutory or legal rights The guarantee does not cover Accidental damage misuse or use not in accordance with the instructions in these instructions Consumable items Damage due to incorrect installation modification or unauthorised service work The manufacturer disclaims any liability for incidental or consequential damage 15346 ECN3219 8