1. MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG 1 GENERAL OUTLINE Electromechanical operator designed to automate residential type gates The operator keeps the gate blocked on closing and on opening without needing an electric lock The operator has no mechanical clutch It must be controlled by an electronic control panel provided with torque setting The end of stroke operation is managed by the control panel GROUND is a series of powerful and silent gearboxes made for the automatic movement of the winged gates and doors up to 3 meters for the leaf GROUND OIL and GROUND 24 V version prepared for intensive use are an ideal choice for condo applications 2 INSTALATION Preliminary checks Check that e The gate structure is sufficiently sturdy e Also make sure that the actuator pushes against the leaf reinforced section e The leaves move manually and without effort all along their stroke e The door stop plates are fitted at the end of both closing and opening strokes e If the gate has not been recently installed check the wear condition of all components e Repair or replace faulty or worn parts moto riduttore una piazzola in cemento Power supply cable The board power supply cable must be of the H 05 RN F type or equivalent The equivalent cable must guarantee permanent outside use rated voltage of 300 500 V MATT di LIEVORE SRL Via Bi
2. Anyone using the automation must be instructed in its operation and controls 10 MAINTENANCE When carrying out maintenance operation on the controller disconnect it from the mains power supply The actuator does not require periodical maintenance operations e Check the safety devices of the gate and automation e Periodically check the pushing force and correct the value of the electric torque in the control board if necessary e In case of unsolved operation failures disconnect the unit from the mains power supply and ask for the intervention of qualified personnel installer When the unit is out of order activate the manual release to perform manual opening and closing maneuvers 11 NOISE The aerial noise produced by the gear motor under normal operating conditions is constant and does not exceed 70dB A 12 TROUBLES AND SOLUTIONS Incorrect operation of gear motor MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG Check for the presence of power supply to the gear motor using a suitable instrument after opening or closing commands have been given If the motor vibrates but does not turn the causes could be the following a incorrect connection of the C common wire b operation capacitor not connected to the terminals on the control board c if the moving direction of the leaf is opposite to the right one invert the motor running connections
3. Incorrect operation of the electrical accessories All control and safety devices can cause in case of failure malfunctioning or stoppage of the automation To identify the failure it is advised to disconnect all the devices of the automation one by one until the one causing the problem is found After fixing or replacing the defective device reset all the devices previously disconnected Refer to the relevant instruction manual for all the devices installed on the automation 13 MANUAL MODE a L A amp DI Se f lt JA In case of interruption of the power supply failure or need activities on the plant is possible to operate the gate in manual mode as shown in Fig 4 Insert the key in lock release lever and rotate in order to open it Pull off the lever up to a corner MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG over 90 and make the manoeuvres you like At the end of the operations restore the lever in the starting position 14 CARATTERISTICHE Supply Engine supply Engine power Max weight Max thrust Thermal protection Temperature range Cycle Weight MIG 400 230 24 220 70 300 400 300 integrated 25 70 90 40 9 MIG 600 230 220 400 600 690 integrated 25 70 50 9 5 MIG 1000 230 220 500 1000 870 integrated 25 70 50 10 MATT di LIEVORE SRL Via Bianche 7 36010 Carr
4. S2 Sec 2 trasformatore 22 V MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG WARNINGS Correct controller operation is only ensured when the data contained in the present manual are observed The Company is not to be held responsible for any damage resulting from failure to observe the installation standards and the instructions contained in the present manual The descriptions and illustrations contained in the present manual are not binding The Company reserves the right to make any alterations deemed appropriate for the technical manufacturing and commercial improvement of the product while leaving the essential product features unchanged at any time and without undertaking to update the present Dichiarazione CE di conformita Con la presente dichiariamo che il prodotto RED 2 4 6 conforme alla direttiva sulla compatibilit elettromagnetica 89 336 CCE 93 68 CEE Norme applicate in particolare EN 55022 EN 61000 3 2 EN 61000 3 3 EN 50082 1 Norme nazionali applicate UNI 8612 Lievore srl MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346
5. not in use If one of the normally open inputs START and STOP is closed or one of the normally closed inputs is open the TEST LED flashes at high frequency In this case it is not possible to carry out the learning strokes procedure MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG OPERATING MODES CONDOMINIUM AUTOMATIC The gate is opened when the START button is pressed whether the gate is closed or being closed The START command is ignored while the gate is being opened whereas during the pause phase it makes the timing of this phase restart After pressing STOP pressing START closes the gate SUPERAUTOMATIC The gate is opened when the START button is pressed whether the gate is closed or being closed While the gate is being opened however it produces a STOP after which a subsequent START closes the gate During the pause phase pressing the START button closes the gate After pressing STOP pressing START closes the gate AUTOMATIC The gate is opened when the START button is pressed whether the gate is closed or being closed The START command is ignored while the gate is being opened whereas during the pause phase it makes the gate close again After pressing STOP pressing START closes the gate SEMIAUTOMATIC The START button controls the opening closing and halting of the gate After it is opened it is necessary to press the START button to clos
6. action 4 STOP EM If DIP 4 ON stops any boom action boom remains closed until command is activated than star opening Opening if boom closing if active no action 5 PHOTO If DIP 8 OFF change direction if boom closing if active no action 6 SAFETY If DIP 8 ON Se DIP 8 ON OFF change direction if boom closing or opening if active no 7 COM Common for inputs Normally closed contact limit switch closing 8 L S C Normally closed contact limit switch opening 9 L S O 10 COM Common for inputs 11 K OPT Fast flashing during closing slow flashing during opening light on if boom is open light off if boom closed 12 K OPT supply accessories 24V CC picture down 13 V24V Positive supply accessories 24V CC 14 V24V Negative supply accessories 24V CC MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG JP1 NC 4 24V 3 2 24V m 1 JUMPER TRA 1e2 COMUNE RELE 12 M1 A 24V JUMPER TRA 2e3 COMUNE RELE 12 M1 A 24V 11 12 JUMPER TRA 3e4 COMUNE RELE 12 M1 LIBERO K OPT CONNECTION M4 LOCK OR LBC Active during opening closing fixed if boom stopped LOCK OR LBC FLASH Flashing during opening closing if DIP 1 ON preflashing 3 sec before any action FLASH M1 Motor M1 CONNECTION M3 GND antena ANTENNA CONNECTION CN2 S1 Sec 1 trasformatore 22 V 0 com trasformatore 0 V
7. 5 390346 USER S MANUAL MIG 5 FIXING RACK AND END RUN DEVICE Position the first element of rack on the cogwheel previously unlocked as in Fig 5 Following fix the element to the gate in the way you wish by applying to it the other elements of rack necessary ensure that all be united and aligned Locate the desired position and fix end run device F on Rack as indicated in the previous Fig 2 those with grains included Close the release lever and perform the necessary electrical connections 6 THE ELECTRICAL PLANT SET UP Fig 6 Lay out the electrical installation fig 6 with reference in force for electrical installation The mains power supply connections must be kept totally separate from the service connections photocells electric edges control devices etc MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG Connect the control and safety devices in compliance with the previously mentioned electrical installation standards The main automation components are Control panel and incorporated receiver Pair of outside photocells Key selector Pair of inside photocells Blinker tuned in with antenna 1 2 4 channel transmitter Operator Antenna cable Warning For actuator wiring and accessory connection refer to the relevant instruction manuals The control panels and accessories must be suitable for use and conform to current standards Should
8. Automatic Comfort ON OFF OFF Semiautomatic ON OFF ON Step by step DIP Function ON OFF 4 Preflashing Enabled Disabled 5 Flash light type With board Lamp only 6 Photocell retrigger Enabled Disabled DIP 7 DIP 8 Installation type OFF OFF SLIDING GATES The function comfort enables the gate to be closed 5 seconds after the photocells have received a pulse regardless of the timing of the pause setting MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG If comfort is enabled dip 6 don t cares The function photocell retrigger makes the timing of the pause restart if the photocells are in use during the pause itself After each mode change it is necessary to short circuit JR1 reset contacts for a few seconds so that the change can take effect REGULATIONS Trimmer Function Range TR1 DELAY Pause time From to 140 secondi TR2 TORQUE Motor torque From 20 to 100 TR3 SK CU Slowing speed From 0 to 100 TR4 BRAKE Brake intensity From 0 to100 The TR1 DELAY trimmer regulates the timing of the pause the time the gate remains still before being closed automatically which varies from 1 to 120 seconds The TR2 TORQUE trimmer regulates the torque of the motor For motors equipped with a clutch or for oil pressure motors it is necessary to rotate the TR2 TORQUE trimmer to the maximum extent pos
9. S LINIT YOLOW NUDE 40 ALINILISNIS 4 HLIM 69 HOLINS nunasang E IwNDE 4 SNIYH Y0119YdyI Woo PIN We S N T NOLINGHSNd AJA ne ral Ken Mz nz ON IN ON OTs LHOII 9NIN3dO 10114 NeRusacad 90S 18815 NOLIAGHSNd I9NYILNI KUW MSZ IbN0EZ ONIHSY14 n Oy GETS unde 3d nbz CE fet or e IN no Ct 2 11390L0Hd wa ON N io S331N30 ALIHHS MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG 15 ELECTRONIC EQUIPMENT L1LW 24V Firmware versione 1 02 w c42 c43 TR OPEN TR CLOSE SP SIK DELAY BRARSIK PFI T FI Ba TRI To To m4 me BX Ex E i Jo PF2 ee P2 Pi MSF2 m cod 1 u2 1 E N a a 10 o o TI LI c39 A AA 3 I e a H u H L_ JEXPI CN2_ _ sexe2 L
10. T 1M3 JRES TTI kz 3 3 Di DL3 DLI DL2 DLE DL DS DLI DLLO a y 5 HAHAHAHAHA m m a m LAA Ea PAGA Eas A Eas A Ees TR E Na LA I E o C SRC308 1 nsa mo LOCK Tos 05 65 di OP ae E A0 Ao E g 48 5 YG 8 19 lo NG f MI R la e wa E EEE d Ji Ji ji f Kort Ya vex JG ON OFF MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG SETTINGS DIP 7 DIP 6 Operating mode OFF OFF SLIDING GATE DIP Function ON OFF 1 Preflashing 3 SECONDS Enabled Disabled 2 Condominium automatic Enabled Disabled 3 Automatic closing Enabled Disabled 4 Stop function Photocell Emergency button open 5 Closing after photocell action Enabled Disabled 8 Safety mode Always on Only opening JEXP1 20 canale radiocomando Out K OPT Pedestrian passage TRIMMER SET Trimmer Function TR1 TROPEN Opening power TR2 TR CLOSE Closing power TR3 SP SLK Slowing speed TR4 DELAY Pause time from 2 to 120 secondi TR5 BR TRSLK Regulation Slowing speed MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG REMOTE CONTROLS LEARNING The SR equipment is equipped with a built in decoder able to memorize up to 128 rolling code remote controls or one fixed code remote controls Start function In closed gate mode pr
11. USER S MANUAL MIG M G 400 600 1000 24V 230V SLIDING GATE OPERATORS INSTALLATION MANUAL CE MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 d Da d Da he Da sd Da o s sd wi he Da he ea 4 Da ee ea se 4 4 a 4 4 ye s pe o Ka 9 Da 9 se USER S MANUAL MIG GENERAL SAFETY If correctly installed and used this automation device satisfies the required safety level standards However it is advisable to observe some practical rules in order to avoid acci dental problems Before using the automation device carefully read the operation instructions and keep them for future reference Keep children people and things outside the automation working area particularly during its operation Keep radio control or other control devices out of children s reach in order to avoid any unintentional automation activation Do not intentionally oppose the leaf movement Do not modify the automation components In case of malfunction disconnect the power supply activate the emergency release to have access to the automation and request the assistance of a qualified technician installer Before proceeding to any outside cleaning operation disconnect the power supply Keep the photocell optical components and light signal devices clean Check that the safety devices photocells a
12. anche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG maximum temperature on the cable surface of 50 C minimum temperature of 25 C Moreover it must have a minimum section of 3 x 1 5 mm2 and for the cable to hold correctly it must be provided with an external sheath of 7 1 to 9 6 mm The wiring of the terminal board must be carried out as shown in Fig 3 M1 operation 1 M2 operation 2 T earthing N common WARNING When the power supply cable is damaged it must be replaced by the manufacturer or its technical assistance service or else by a person having similar qualification in order to prevent any risk External meausures 130 in ba MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 3 4 POSITIONING FOR BASE PLATE USER S MANUAL MIG prepare the sub structure in order to fix base plate respecting approximately measures like Fig 2 Position the gear motors Fig 3 on the great plate A using the appropriate screws supplied The right coupling between rack and pinion may be carried out by registering of fixing the small plates B to the great through the eyelets associated unlock the gear motors through appropriate release lever Fig 4 For the following positioning and attaching the rack MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 044
13. e VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG 11 ELECTRONIC EQUIPMENT L1 220V INTRODUCTION The electronic equipment Type SIR can be used to control one actuator for a sliding gate The max absorption of the device is 600W per 230V 50Hz The set up of the parameters must be carried out after the installation of all the equipment DESCRIPTION TR1 TR4 Trimmers DSW1 Dip switches DL1 DL8 LED F1 Line 230V fuse F2 Low voltage fuse M1 Signal terminal board M2 Power terminal board CN2 Antenna terminal board K1 K3 Relais TF1 Transformer U1 Microprocessor JR1 Reset jumper MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG PROS PROG DELAY TOOU SR C0BRRRE Ol O TRI TRI TR3 TR4 PI P2 F2 5 MA DSHI z JRI RESET y i TEN deg ret E i 24 T2 JFi UL opi TAL K3 KL K2 lol 1 ne LN3 Ea GND CN1 een at bt le le br lot Ie ci a b amp b ge oe el e e e El e Ma zA T T T T T lt Li M1 lel 2 DL3 DL4 DLE DLE DL 2 E Cat bobo E Eee Te JE Ja Je B Ye ay OR tT lio Lay gn dlan ded didi 240 PS PE 230vac LET YUN INSTALLATION Before making the electrical connections it is necessary
14. e it again While the gate is being opened pressing START halts the gate and another pulse makes the gate close If START is pressed during the closing phase the direction is inverted After pressing STOP pressing START closes the gate STEP BY STEP The gate is opened when START pulse is pressed while the gate is closed The START command produces a STOP during the opening phase subsequently pressing START causes the gate to close and pressing START again produces a STOP After pressing STOP pressing START closes the gate MAINTENANCE MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG There are two 5x20 size fuses on the board that protect the 230V line and the secondary of the transformer The fuses have the following values 230V line F1 5 A fast Secondary F2 630 mA fast Before replacing the fuses it is necessary to turn off the 230V mains power supply The power of these fuses must not be modified There is no other component on the board that can be repaired or replaced by the installation personnel For any other intervention it is necessary to contact technical support SETTINGS DIP1 DIP2 DIP3 Operating mode OFF OFF OFF Condominium automatic OFF OFF ON Condominium automatic Comfort OFF ON OFF Superautomatic OFF ON ON Superautomatic Comfort ON ON OFF Automatic ON ON ON
15. ess the P2 button and hold it down until the TEST LED starts to flash Release the P2 button Within 10 seconds set the remote control button that you want to connect to the START command The completion of the process will be indicated by the simultaneous flash of the TEST LED of the flasher and of the pilot lamp followed by the termination of the flashing of the TEST led With rolling code remote controls repeat the process for each remote control to be set With fixed code remote controls it is sufficient to carry out the process for only one model Pedestrian start function In closed gate mode press the P2 button and hold it pressed until the TEST led starts to flash don t release the button and wait until the flashing speeds up Release the P2 button Within 10 seconds set the button of the remote control to learn and to be connected with the PEDESTRIAN START control When the learning has been carried out it will be indicated by the simultaneous flash of the TEST led flasher and of the pilot lamp followed by the termination of the flashing of the TEST led In case of rolling code type remote controls repeat the operation for each remote control to learn In case of fixed type remote controls it is sufficient to carry out the learning of one single model Complete erasing of all learnt remote controls In closed gate mode press the P2 button and hold it pressed till when the TEST led starts to flash don t release the button a
16. g from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which might occur during use The installation must comply with the provisions set out by the following European Directives 2004 108 CEE 2006 95 EEC 98 37 EEC and subsequent amendments Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG Fit an omnipolar or magneto thermal switch on the mains power supply having a contact opening distance equal to or greater than 3 5 mm Check that a differential switch with a 0 03A threshold is fitted just before the power supply mains Check that earthing is carried out correctly connect all metal parts for closure doors gates etc and all system components provided with an earth terminal Fit all the safety devices photocells electric edges etc which are needed to protect the area from any danger caused by squashing conveying and shearing Position at least one luminous signal indication device blinker where it can be easily seen and fix a Warning sign to the structure The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers components are used Only use original parts for any maintenance
17. nd wait until the flash gets quicker don t release the button and wait until the flash gets very quick don t release the button When the blanking blackout of ALL the learned remote controls has been carried out it will be indicated by the simultaneous flash of the TEST led flasher and of the pilot lamp followed by the ending of the flashing of the TEST led MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG Erasing of one learnt remote controls In closed gate mode press the P2 button and hold it pressed till when the TEST led starts to flash don t release the button and wait until the flash gets quicker don t release the button and wait until the flash gets very quick release the button and push the start button on the remote controller that you want to erase by the ending of the flashing of the TEST led you erased the remote controller LEARNING WARNING the GATE has to be closed Press the P1 learning button for at least 3 seconds until the TEST LED starts to flash then do as follows WARNING If do not start with learning until 10 sec DL4 LED turns off and learning is not done correctly so you have to restart During the learning you have to pay attention on photocells and do not press STOP button otherwise you have to restart learning 1 input START the gate begins to open at standard speed 2 input START When you decide to start the slow s
18. or repair operation Do not modify the automation components unless explicitly authorized by the company Instruct the product user about the control systems provided and the manual opening operation in case of emergency Do not allow persons or children to remain in the automation operation area Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Check that the stated temperature range is compatible with the place where the operator is to be installed If present the hold button hold to run control must be fitted within sight of the door but away from the moving parts at a height of 1 5 m and must not be accessible to the public If the operator is fitted at a height lower than 2 5 m you must guarantee an adequate degree of protection for the electrical and mechanical parts Make sure that squashing is avoided between the moving parts and surrounding fixed parts Fit all the safety devices photocells safety edges etc required to protect the area from any danger of squashing drawing in and shearing After completing the installation ensure that the motor is set correctly and that the protection and release systems operate correctly Anything which is not expressly provided for in the present instructions is not allowed
19. re not obscured by branches or shrubs For any direct assistance to the automation system request the help of a qualified technician installer Have qualified personnel check the automation system once a year Manual release activation could cause the door to be subject to uncontrolled movements in the case where any mechanical faults are present or the door is not balanced Inspect the installation frequently if it shows any unbalance or signs of mechanical damage to cables and supports Do not use the operator if it needs to be repaired Keep the instructions together with the technical brochure for future reference This product was exclusively designed and manufactured for the use specified in the present documentation Any other use not specified in this documentation could damage the product and be dangerous The Company declines all responsibility for any consequences resulting from improper use of the product or use which is different from that expected and specified in the present documentation Do not install the product in explosive atmosphere The construction components of this product must comply with the following European Directives 2004 108 CEE 2006 95 EEC 98 37 EEC and subsequent amendments As for all non EEC countries the above mentioned standards as well as the current national standards should be respected in order to achieve a good safety level The Company declines all responsibility for any consequences resultin
20. rimmer TR4 BRAKE as you need DIP SWITCH From 1to 6 as you need dip switch 7 OFF and dip switch 8 OFF Press the PROG A learning button for at least 3 seconds until the TEST LED starts to flash then do as follows Learning ends when the TEST LED turns off opening slowing xX i gt M M M C The first stort initiates the leaming of the The second stort fixes the starting point The third start close the gate slowings by moving the opening gate of the slowing of the opening CAUTION THE GATE MUST BE CLOSE closing slowing gt gt M gt M M The fourth start fixes the starting point of the The fifth start initiates the leaming The seventh start fixes the point of the closing slowing of the gate of the partial opening by moving partial opening the opening gate M The seventh start close the gate and leaming to store MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG CONNECTIONS oz Gi ar woo dasn LON JAY AZHL dI 8 2 8 99 88g Bay Be Z SLOYLNOD 035019 ATTBWYON IHL NO XIAWNF Y LIA EN waa me N DS OND a s 3 HOLIM
21. sed until the TEST led starts to flash don t release the button and wait until the flashing speeds up Release the PROG B button Within 10 seconds set the button of the remote control to learn and to be connected with the PEDESTRIAN START control When the learning has been carried out it will be indicated by the simultaneous flash of the TEST led flasher and of the pilot lamp followed by the termination of the flashing of the TEST led In case of rolling code type remote controls repeat the operation for each remote control to learn In case of fixed type remote controls it is sufficient to carry out the learning of one single model Complete erasing of the learnt remote controls In closed gate mode press the PROG B button and hold it pressed till when the TEST led starts to flash don t release the button and wait until the flash gets quicker don t release the button and wait until the flash gets very quick don t release the button When the blanking blackout of ALL the learned remote controls has been carried out it will be indicated by the simultaneous flash of the TEST led flasher and of the pilot lamp followed by the termination of the flashing of the TEST led MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG INSTALLATION SLIDING GATE TYPE TRIMMER e Trimmer TRI DELAY as you need e Trimmer TR2 TORQUE to the minimum e Trimmer TR3 SK CU as you need e T
22. sible i e a complete clockwise rotation The TR3 SK CU trimmer regulates the speed at which the timing is slowed which can be regulated within the safety parameters By regulating the TR3 SLACK trimmer to the maximum extent possible i e a complete clockwise rotation the slowing does not take place see learning procedure without slowing The TR4 BRAKE trimmer regulates the brake intensity To disable the brake it is necessary to regulate the trimmer to a minimum MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG REMOTE CONTROLS LEARNING The SR equipment is equipped with a built in decoder able to memorize up to 128 rolling code remote controls or one fixed code remote controls Start function In closed gate mode press the PROG B button and hold it down until the TEST LED starts to flash Release the PROG B button Within 10 seconds set the remote control button that you want to connect to the START command The completion of the process will be indicated by the simultaneous flash of the TEST LED of the flasher and of the pilot lamp followed by the termination of the flashing of the TEST led With rolling code remote controls repeat the process for each remote control to be set With fixed code remote controls it is sufficient to carry out the process for only one model Pedestrian start function In closed gate mode press the PROG B button and hold it pres
23. the opening or closing direction be incorrect it is possible to invert the connections of operation 1 and operation 2 on the control board The first command after an interruption of the power supply should be an opening maneuver 7 CHECKING THE AUTOMATION Before considering the automation completely operational the following checks must be made with great care e Check that all the components are firmly anchored e Control all the safeties work properly i e photocells pneumatic skirt etc e Check the emergency maneuvers control e Check the opening and closing maneuvers using the controls e Check the control unit s electronic logic in normal or customized operation 8 USE OF THE AUTOMATION Since the automation may be remote controlled either by radio or a Start button it is essential that all safeties are checked frequently MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG Any malfunction should be corrected immediately bya gualified specialist Keep children at a safe distance from the field of action of the automation 9 THE CONTROLS With the automation the gate has a power driven opening and closing The controls can come in various forms i e manual remote controlled limited access by magnetic badge etc depending on needs and installation characteristics For details on the various command systems consult the specific instruction booklets
24. to turn off the mains of 230V 50Hz and regulate the motor torque to a minimum Use 0 5mm2 wires to make connections to the pushbuttons photocells and 24V power supply For connections to the electric lock flasher and motors it is necessary to use at least 1 5mm2 wires Use wires of at least 2 5mm2 to make connections to supply mains of 230 V 50Hz MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 M1 terminal board START STOP ST P PHOTO SAFETY L S C L S O COM 24V 24V W LIGHT M2 terminal board USER S MANUAL MIG Normally open pushbutton opening closing Normally closed pushbutton stop Normally open pushbutton pedestrian opening Normally closed input external photocell Normally closed safety contact Normally closed contact limit switch closing Normally closed contact limit switch opening Common for inputs and warning light Positive supply accessories 24V CC Negative supply accessories 24V CC Warning light 24V 3W max L Input 230V 50Hz Line N Input 230V 50Hz Neutral Flash light common contact FLASH Flash light 230V 50Hz 15W max COM Motor common coils C Motor closing windings O Motor opening windings It is necessary to connect a capacitor between C and O terminals It is necessary to clamp the cables of the M1 signals terminal board to M2 power terminal separately Fit a jumper cable on the normally closed contacts when they are
25. troke phase press START the slow stroke phase starts After 3 seconds boom starts closing the boom begins to close at standard speed MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG 3 input START When you decide to start the slow stroke phase press START the slow stroke phase starts until the limit switch After 3 seconds gate starts opening 4 input START gate stops at pedestrian point decided After 3 seconds gate starts closing Wait until the DL4 LED turns off Learning finished The subsequent maneuver will be standard within the parameters just set If one of the normally open inputs START CL SP OPEN is closed or one of the normally closed inputs STOP PHOTO SAFETY is open the TEST LED flashes at high frequency In this case it is not possible to carry out the learning strokes procedure Fit a jumper cable on the normally closed contacts when they are not in use MATT di LIEVORE SRL Via Bianche 7 36010 Carre VI Tel 0445 892223 Fax 0445 390346 USER S MANUAL MIG CONNECTION M1 Opening if boom is down or if boom is closing 1 OPEN Opening if boom is down stop during opening if DIP 2 OFF closing if boom is 2 START stopped opening if boom is closing Pedestrian passage with boom down closing if boom is open 3 CL SP If DIP 4 OFF stop any boom action if activated no