1. identify zones To display descriptors the system must be disarmed and ready to arm Press and hold the READY key until the built in instructions for that key appear then release the key The zone descriptors will appear one at a time for about 2 3 seconds each For faster viewing press the READY key to display the next descriptor in numerical order and so on When all descriptors have been displayed the control will exit display mode To exit the display mode before all descriptors have been displayed enter the security code and press the OFF key Viewing Downloaded Messages Users may occasionally receive a message from their installation company displayed on an alpha keypad When this occurs the keypad will display Message Press 0 for 5 secs Instruct the user to press and hold the 0 key to display the central station s message Note that the system must bein the READY state to view these messages Using The Built in User s Manual Panic Keys 24 4 An abbreviated User s Manual is stored in the system s memory and can be particularly useful to the end user if the printed User s Manual is not conveniently accessible when the user needs to perform a seldom used and unfamiliar system procedure The Built in User s Manual is displayed on an alpha keypad by simply pressing any of the function keys e g OFF AWAY STAY MAXIMUM BYPASS INSTANT CODE TEST READY and CHIME for approximately 5 seconds and then releasing it Abbrev
2. EVICE NO Voice ENTER DEVICE CODE NOW 00 QUIT 01 Enter the 2 digit number of the relay to be activated nn DEVICE IS OFF Voice voicedescriptor DEVICE nn ON OFF FOR voice HIT 0 0FF 1 ON descriptor ON ENTER 1 FOR voice descriptor OFF ENTER 0 Press O or 1to turn the device off or on respectively nn represents the 2 digit relay number and voice descriptor is the relay voice descriptor programmed by the installer see relay descriptor programming nn DEVICE IS OFF Voice voice descriptor DEVICE nn ON OFF TO EXIT From a keypad press to continue The ENTER DEVICE NO prompt will appear From a telephone keypad enter 00 to exit or enter the next relay number to be programmed The current on off state of that relay will be annunciated as described above Alternatively if 6 seconds elapses with no key depression the voice module will annunciate the ENTER DEVICE CODE NOW message A relay may be designated as restricted to prevent inadvertent activation deactivation by users Only the Installer Code can override this restriction in Raday Programming in the 93 Menu Mode Programming 24 5
3. SECTION 24 Keypad Functions In This Section General Information Arming Functions Global Arming Access Control Partition Go To Command Viewing Capabilities Of A User Viewing Zone Descriptors Viewing Downloaded Messages Using The Built in User s Manual Panic Keys Manual Reay Activation Mode 70 Mode General Information The keypad allows the user to arm and disarm the system and perform other system functions such as bypassing zones viewing messages from the central station and displaying zone descriptors Zone and system conditions alarm trouble bypass etc are shown in the display window When an alarm occurs keypad sounding and external sounding will occur and the zone s in alarm will be displayed on the keypad Pressing any key will silence the keypad sounder for 10 seconds Disarming the system will silence both keypad and external sounders When the system is disarmed any zones that were in an alarm condition during the armed period will be displayed memory of alarm To clear this display simply repeat the disarm sequence enter the security code and press the OFF key The keypads also feature chime annunciation and 3 panic keys for silent audible fire or personal emergency alarms which can notify the central station of an alarm condition if that service is connected 24 1 VISTA 40 Installation Instructions Arming Functions The following is a brief list of system
4. commands F or detailed information concerning system functions refer to the User s Manual Display Faulted Before arming the system must bein the READY condition all zones Zones must be intact If the NOT READY message appears press the READY key to display faulted zones Arming Away Enter code 2 AWAY Arming Stay Enter code 3 STAY all zones designated as zone types 4 and 10 will be automatically bypassed Arming Instant Enter code 7 INSTANT same as STAY without entry delay Arming Enter code 4 MAXIMUM same as AWAY with out entry delay Maximum Enter code 1 OFF Bypassing Zones Enter code 6 BYPASS 3 digit zone number To automatically bypass all faulted zones use Quick Bypass method Enter code BYPASS Chime Mode Enter code 9 CHIME Toturn chime mode off enter code CHIME again Quick Arming Note that if QUICK ARM is enabled field 29 the key can be pressed instead of entering the security code for any of the arming procedures AWAY STAY INSTANT MAXIMUM A user 2 code must be programmed into the system in order for the Quick Arm feature to work SUMMARY OF ARMING MODES moas Features For Each Arming Mode C Exit Dalay Entry Delay Perimeter Armed interior Armes wo vs m wo s m wo es e INSTANT 24 2 Global Arming Section 24 Keypad Functions If enabled for the user the alpha keypad will display the follo
5. iated instructions relative to the key that has been pressed will then be displayed 2 lines of text are displayed at a time This function operates in either the armed or the disarmed state There are three panic key pairs shown below that if programmed can be used to manually initiate alarms and send a report to the central station Each key pair can be individually programmed for 24 Hour Silent Audible or Auxiliary Emergency responses as well as Fire The panic function is activated when the appropriate key pair is pressed at the same time The panic functions are identified by the system as follows PANIC Displayed as Zone 1 95 For alpha keypads these panic keys 4 3 96 can also be programmed with an alpha 48 99 descriptor Section 24 Keypad Functions For the panic functions to be of practical value the system must be connected to a central station Manual Relay Activation Mode 70 Mode The system allows users to manually activate relays by keypad command using either the keypad or a telephone keypad if VIP module is used The user will be prompted either by keypad alpha display or telephone voice module To activate relays from a keypad enter 4 digit security code 70 To activate relays using a telephone and VIP module first dial the 2 digit phone access code When the system acknowledges the access enter 4 digit security code 70 The following prompts voice responses will begin ENTER D
6. r code 0 The relay will pulse for 2 seconds Partition GOTO Commands Each keypad is assigned a default partition for display purposes and will show only that partition s information To see information for another partition or perform system functions in another partition use the GOTO command code partition number 0 2 The keypad will remain in the new partition until directed to go to another partition or until 120 seconds has elapsed with no keypad activity To return to your home partition enter partition number 0 You must program data field 2 18 to enable the GOTO function This is a partition specific field that must be set for each partition the user wants to access from another partition s keypad 24 3 VISTA 40 Installation Instructions Viewing Capabilities Of A User The alpha keypad will display the partitions that a user is authorized for the user number and the authority level for all partitions authorized Enter code The user s capabilities in each authorized partition will typically be displayed as follows Part 1 AO WHSE The user s Open Close report capability is shown by the dot User 01 Auth 1G following the authority level If Open Close is not enabled for a user the dot will not appear Viewing Zone Descriptors The Alpha Keypads can display all programmed descriptors which is useful to the installer when checking entries and can be helpful to the user when there is a need to
7. wing ARMALL 0 NO 1 YES Access Control If NO the keypad prompts for arming each partition individually If YES the system attempts to arm all partitions allowed by this user If there are any faults open doors windows etc the keypad will display them See notes below These faults must be corrected or the zone bypassed before arming will occur When faults are corrected repeat the arming procedure 1 When using the Global Arm feature if there are faults in any of the selected partitions the system will enter a summary mode in which the faulted zones of all of the selected partitions will be displayed These faults must be corrected or bypassed code BYPASS will attempt to bypass the faults in all of the selected partitions This summary mode will end in approx 120 seconds if no keys are pressed If when disarming the system using a Global Disarm any of the selected partitions has a condition which would cause the keypad to beep such as alarm memory or a trouble condition the system will enter asummary mode The keypad will display the alarm memory or trouble conditions of all of the selected partitions This mode will continue until either approximately 120 seconds elapses or a second disarm is entered The system has the capability to utilize access control One relay may be used for access control in each partition The relay is programmed in data field 1 76 To activate this relay the user enters his use