1. Cera USER MANUAL Design The Cera is designed for simplicity and reliability They are all hand assembled so warm up times can vary slightly a couple sec onds The Cera Cartridge simply threads into the top of the body The body holds an 18650 Battery of 5 V If you did not purchase the bat tery from us it will need to contain the following characteristics 18650 size 5 V and a minimum of 6 amperage rating he mAh will deter mine how long each charge lasts For performance and life we recom mend the batteries available on our website The switch that powers the vaporizer on off is momentary and will need to be depressed while in use Once you let go the power is off This is located on the very bottom of the device You can easily hold the vaporizer with one hand while depressing the power button by making a fist on the bottom and using the index middle or opposing finger to press the button Each cartridge will have a different warm up time This will vary de pending on what type of material is loaded as well TABLE OF CONTENTS Configuration Break Down Basic Operation Loose Leaf Steps E Liquid Steps E Liquid Cleaning Oil Steps Oil Cleaning ON BwWN CONFIGURATION Optional Cartidges sold sepra ly I i 4 q i P f o I a af 3 ns r 4 a 2 j 4 a 4 E x 4 I pes Es I Le ts Loose Leaf Oil Liquid B
2. 4 dr A gt di r E Caution Using the Cera NN for an extended amount of time can make the device hot to the touch LOOSE LEAF CLEANING Dryu Wet Wipe Remove Ceramic Top Cap give a 20 N second dry burn this will warm the residue on the heating chamber With a Q Tip or Tissue simply wipe a the residue off the ceramic surfaces gE this works very well if the Q tip or E tissue is lightly soaked with Isopropyl ae Alcohol Repeat if necessarily Mouthpiece Cleaning Remove Top Cap and press down on mouthpiece the two should sepa rate be sure not fo loose the O ring that sits around the mouthpiece With a Q Tip or tissue wipe the inside of the cap of residue do the same with the mouth A piece and O ring A To clean the Mouthpiece take a pipe cleaner and run the cleaner through the air passages Start with the top passage then continue to the side passages For the lower air passages the pipe cleaner should pass through and exit out of the opposite side Repeat as need once or twice should be sufficient w gt E LIQUID STEPS E Liquid Design This Cartridge is designed for PG or VG based E liquids The Cartridge utilizes porous ceramic as wicking material Each Cartridge is made up with 3 various porous ceramics Top wafer Circle wick and RES wick Reservoir Expansion System RES is integrated part of the cartridge its purpose is to create add
3. REAK DOWN Loose Leaf Mouthpiece F ge bee i _Z O nN Oil Liguid Heating Core Switch Ceramic Body BASIC OPERATION a u i To insert battery turn Insert charged counter clockwise to remove Bottom Switch Caution Heating a Chamber can be extremely hot Turn counter clockwise to remove heating core Depress and hold Switch to turn on battery positive side Up amp re insert Switch To load pull Top Cap off while Applying a clockwise twist Turn clockwise to re insert Heating Core LOOSE LEAF STEPS Peparing Material For the first technique exploit the advantages of the basic Cera system to simplify the task by drying the material Grind your botanicals and cure dry them well Removing the water before is important if has to be very dry to vape well the water has to be evap orated off first robbing vaping power in the process El Loading Material Load the Cartridge with a medium fo fine grind of the material Fill Cartridge to the brim and lightly pack the material down Place the Top Cap and Mouthpiece over the Cartridge Warm Up Proceed with a 20 30 second warm up time This is done by Turning on The device by depressing and holding the momentary Switch Follow up with a very slow and steady inhale It is important to note that the hot air needs fo con tact and circulate the chamber air bringing the material up To v
4. aping temperature Note the quicker the draw the cooler the chamber will become while a slower draw will 1 warm up the chamber each user will find their own prefer LOOSE LEAF STEPS cont Inhalation The quicker the draw the cooler the chamber will become while a slower draw will warm up the chamber each user will find their own preference After each inhalation release the switch to not overheat the material or the device this will also increase battery life After the first initial warm up the device will retain the heat back to back inhalations will not require a warm up each time It is recommended for the user to try differ ent inhaling techniques as some may work well for some users while other techniques will not 2 A Checking Material Pull the Top Cap off at anytime to check the progress Over time the center part of the material will shift from green to brown as vaping progresses The darker area will naturally spread to all of the material no stirring is normally needed but can be done Most users stop vaping when production tapers off or a burnt popcorn taste appears When these symptoms occur check material and reload if needed Reloading When the vapor production tapers off if will indicate that most of the material has been vaporized Remove top cap fo discard material you will notice a change in color reload material as mentioned in Loading Material y i dal
5. ating element as this may damage the heating element 7 3 Wh OIL CLEANING CONT Warning Ulfrasonic Cleaners are not recommended and will void the warranty the frequency of the cleaner has had a tendency to cause failure to heating chambers Do Not attempt fo open heating chamber by removing screws and internally clean This will void warranty 14
6. d the heating core suspending the material in close proximity for efficiency and performance Porous Ceramic Material needs to be able to melt into a liquid to be absorbed into the porous ceramic materials Dried concentrates should be used in the Loose Leaf Cartridge as they do not melt down and stay Solid Lo Loading Material FS To load pull the mouthpiece off and place material on top of the porous ceramic wick be cautious to not poke or scrape the porous ceramic wick and cause unwanted damaged Once the substance is placed in the chamber depress the switch to warm up the chamber you will notice the material liquefy and soak into the porous ceramic For thicker wax materials use a toothpick to A gently stir or pop any bubbles Warm up amp Inhalation When material is fully saturated into the porous ceramic the device is now ready fo be used Depress switch fo give a 5 second warm up Slowly inhale until vapor becomes thick once up to temperature inhale as you please 7 amp 11 OIL STEPS CONT Checking amp Reloading When vapor production tapers off this indicates that most of the material has been vaporized Remove the mouth piece and check if the material walked up the walls of the chamber if so use a applicator fo push material back down fo the porous ce ramic once again be sure not to damage top ceramic To reload simply repeat the steps stated in Loading Material it is sug
7. gested fo put 0 25 gram of material for reloading Mouthpieces e e a Ceramic Top Cap 510 Mouthpiece Ceramic Top Cap Mouthpiece with 510 mouth piece 12 OIL CLEANING _ Dry Clean Chamber can be extremely hot Dry clean First pull off mouthpiece Ww J before cleaning To dry clean simply Es turn the device on for 20 seconds and let the device cool off for another 20 seconds repeat this cycle 3 5 times or until you see visible vapor dissipate Use caution with excessive cycles as the heating core can become very hot be 20 Seconds on 20 Seconds off 91 Alcohol lsopropy Alcohol Soak o a Unthread the heating chamber as described in Basic Operation Once removed get a container to hold the Isopropyl Alcohol place the heating chamber in the container and make sure to fully submerge the cham ber Soak for 15 30 minutes and repeat if necessary We also recommend to rinse or to boil chamber after an Isopropyl soak Once cleaned allow adequate time to dry we recommend fo let dry overnight Do not to force dry using ovens or internal heating element as this may damage the heating element Bolling ats sn Unthread the heating chamber as described in Sak N Basic Operation Place heating chamber in boiling water for 15 30 minutes repeat if nec essary Once cleaned it is important to fully dry out the heating chamber before use Do not to force dry using ovens or internal he
8. itional wicking and fo provide a sealed air path to prevent leakage Air is forced through the RES from external air inlets then fed to the pours ceramic wicks sur rounding the heating element First Time Filling o nro When receiving your E Liquid cartridge place 3 5 drop of EX LL E Liquid directly on top of the ceramic wick Notice how E a the wicking material absorbs the liquid down into the Car tridge Be sure not to overfill the Cartridge overfilling can cause over saturation to the wicking material and can result in poor performance Inhalation Depress the switch to activate the device within 2 3 seconds a light fizzle should be herd from the cartridge This sound indicates the device is ready and can be used amp as pleased Take slow long drags through the mouthpiece i while depressing the switch Release the switch after each drag to conserve power and to not burn any E Liquid N 7 E LIQUID STEPS Cont Refilling When vapor production tapers off this may be indication to refill the cartridge A dry peppery throat hit can also indicate that the cartridge needs to be refilled and is low on E liquid To Refill simply remove mouthpiece and add 2 3 drops of E Liquid This can also be done through a drip tip style mouthpiece Allow a few seconds for the porous ceramic fo absorb the E Liquid Blowing lightly through the mouthpiece can help push the E Liquid down into the cartridge Once again do not overfil
9. l the cartridge If you k do find the cartridge overfilled fallow our troubleshooting section A Troubleshooting If you are having trouble producing vapor with your device follow these steps to pin point issues 1 Make sure that the battery is fully charged a weak battery will cause inade quate heat to produce vapor 2 A quick test fo see if the heating core is working depress the switch for 2 3 seconds a hiss sizzle sound should omit from the cartridge 3 Make sure the cartridge is adequately filled 4 If the vaporizer is still under performing after the above steps the cartridge can be flooded from being overfilled a simple method is to gently blow through the mouthpiece fo force E Liquid into the RES Wick away from the heating element If the RES Wick is already saturated E Liquid may leak from the outer air inlets wipe with tissue paper if needed E LIQUID CLEANING Cleaning Cleaning the cartridge is part of general main ten ance and can increase the longevity of the E Liquid Cartridge Cleaning can depend on the E Liquid intervals and usage If there is a harsh burnt taste poor draw or tapered vapor production cleaning is recommended fo re store performance Flushing amp Drying Unscrew the Cartridge and remove the mouthpiece before flushing the car tridge Run the Cartridge under hot water Use the mouthpiece to blow the water through Cartridge and je out through the air inlet
10. s repeat this KL pro cess several times Thoroughly force the water out and let the car tridge sit up right for 24 hours Do not force dry or turn on the heating element this will fatigue the wire and will risk heater ele ment failure E LIQUID CLEANING CONT Storage When storing the liquid cartridge longer then a month it is recommend ed to flush out the cartridge as de scribed E Liquid has a tendency fo dry up and harden if not used on the regu lar basis to prevent crystalized build up be sure to thoroughly flush and dry car tridge if stored for an extended amount of time Warning Ulfrasonic Cleaners are not recommended and will void the warranty the frequency of the cleaner has had a tendency to cause failure to heat ing chambers Do Not attempt fo open heating chamber by removing screws and inter nally clean This will void warranty OIL STEPS Cleaning ls recommended when performance is lacking it is part of periodic maintained that varies with usage We do recommend cleaning when the device is stored for a long period of time as material can harden and can damage the Heating Core Material amp Core Design This Cartridge can hold up to 5 grams of oil wax or butters There are some materials that will work but aren t ideal for this cartridge A few things to keep in mind The oil cartridge is made up of 4 porous ceramic rings and 1 ceramic wafer on top The rings surroun

Download Pdf Manuals

image

Related Search

Related Contents

ストラップ(音量) ・・・・・・ ー  Kenwood HM-333 Stereo System User Manual  健やか・彩り・輝きのまち  Graphtec RIP User Manual I Installation  IM-E/IM-V Series Network Dome  inc.jet OEM Developer`s Kit User Manual  BME 290 Final Report - University of Connecticut  特記・図面  Dimension One Spas Aurora HP User's Manual  User Manual - Leica Microsystems  