1. Figure 2 and Table 1 define the unit Figure 2 Table 1 TBUS 6W Table Connection Bus Top View TBUS 6W Table Connection Bus Features Feature Function 1 Connecting Surface See Figure 3 and Table 2 2 Black Anodized Lid Covers the connecting surface leaving the table surface neat and tidy 3 Mounting Plate Outer Rim Fits over the table surface 4 Enclosure Inserts into the table cutout 5 Height Adjustment Screws Six screws for adjusting the height of the connecting surface two on the front and two on each side 6 Rubber Protectors Protect the table surface when mounting the unit one on each side 7 Locking Butterfly Screws Tighten to lock the mounting butterfly screw one on each side 4 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the TBUS 6W Table Connection Bus Feature Function 8 Mounting Brackets Fit in the bracket slits after inserting the enclosure into the table to secure the unit to the table surface one on each side 9 Mounting Butterfly Screws Tighten to secure the unit to the table surface one on each side 10 Tie Holes Anchor the self locking ties to secure the pass through cables to the inside walls of the unit 8 pairs of holes 4 pairs on the front and 4 pairs on the rear panel Figure 3 and Table 2 define the connecting surface Figure 3 TBUS 6W Connecting Surface Table 2 TBUS 6W Connectin
2. 5 Connect the to the table cables see section 5 4 see section 5 3 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3 Overview The Kramer TBUS 6W is a high quality anodized aluminum table mounted connection bus for boardrooms and conference rooms Its attractive enclosure is designed to provide maximum connectivity in the smallest possible footprint The unit is sturdy cost effective and easy to install The TBUS 6W includes e Two RC 3TB 3 button remote controls supplied separately e Six 9 0mm pass through bushings and two 12 5mm pass through bushings e Two universal power connectors To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position the TBUS 6W away from moisture excessive sunlight and dust Figure 1 TBUS 6W Table Connection Bus 1 See compatibility restrictions in the Specification section 6 2 Available from Kramer Electronics on our Web site at http www kramerelectronics com Your TBUS 6W Do Beware of sharp edges on the inner and outer rim of the mounting plate and on the lid of the TBUS 6W They can cause serious injury not place heavy objects on top of the TBUS 6W Your TBUS 6W
3. not supply grounding to plugs in Central Europe and France Order country specific sockets instead 4 The Universal socket does not fit South African plugs KRAMER SIMPLE CREATIVE TECHNOLOGY LIMITED WARRANTY Kramer Electronics hereafter Kramer warrants this product free from defects in material and workmanship under the following terms HOW LONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not au
4. will void user authority to operate the equipment gt Usethe supplied DC power supply to feed power to the machine B gt Please use recommended interconnection cables to connect the machine to other components FCC and CE approved using STP cable for twisted pair products For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Safety Warning Disconnect the unit from the power supply before opening servicing Caution 9001 o lt g AW a Institute of Quality amp Control Kramer Electronics Ltd Web site www kramerelectronics com E mail info kramerel com P N 2900 000594 REV 1
5. Connection Bus e 2 table clamps e 2 power cords e 6 self locking ties e Cut out template e 4screws for holding template e This user manual 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables 1 GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters GROUP 11 Sierra Products 2 We recommend that you use only the power cord supplied with this device 3 Download up to date Kramer user manuals from our Web site http www kramerelectronics com 4 The complete list of Kramer cables is on our Web site at http www kramerelectronics com 1 Getting Started 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps Step 1 Cut an opening in the table see section 5 1 Cut out an opening in your table using the cutout template Step 2 Adjust the height Step 3 Remove the of the connecting rubber guard and insert surface see section 5 2 the unit see section 5 3 Step 4 Secure the unit Step
6. Kramer Electronics Ltd USER MANUAL Model TBUS 6W Table Connection Box Contents Contents 1 Introduction 2 Getting Started 2 1 Quick Start 3 Overview 4 Your TBUS 6W 5 Installing the TBUS 6W Table Connection Bus 5 1 Cutting an Opening in the Table D2 Adjusting the Height of the Connecting Surface 5 3 Installing the TBUS 6W in the Cut Out Opening 5 4 Connecting the Cables 6 Technical Specifications Figures Figure 1 TBUS 6W Table Connection Bus Figure 2 TBUS 6W Table Connection Bus Top View Figure 3 TBUS 6W Connecting Surface Figure 4 Cutout Dimensions Tables Table 1 TBUS 6W Table Connection Bus Features Table 2 TBUS 6W Connecting Surface Features Table 3 Technical Specifications of TBUS 6W LAIZIZJAN Ah Yuka BS Du Bu nN Introduction 1 Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function Thank you for purchasing the Kramer TBUS 6W table connection bus which is ideal for boardrooms conference and training rooms The package includes the following items e TBUS 6W Table
7. from underneath Secure the power cords to the tie holes using the included self locking ties If needed secure the cables Do not secure the cables too tightly or too loosely Leave a small amount of slack After the unit is connected to mains power and the proper cables TBUS 6W is ready for use Technical Specifications 6 Technical Specifications TBUS 6W technical specifications are shown in Table 3 Table 3 Technical Specifications of TBUS 6W POWER SOURCE AC power limits 100 240V AC 50 60Hz 5A universal connector 4 FUSE RATING T 6 3A 250V OPERATING TEMPERATURE RANGE 5 to 45Deg C OPERATING HUMIDITY RANGE 10 to 90 RHL non condensing STORAGE TEMPERATURE RANGE 20 to 70Deg C STORAGE HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS Top plate 171 6mm x 261mm 6 8 x 10 3 W D Enclosure 203mm x 121mm x 130mm 8 0 x 4 8 x 5 1 W D H WEIGHT TBUS 6W 1 35kg 2 8lbs approx Table clamps 0 25kg 0 6lbs approx ACCESSORIES 2 power cords table clamps self locking ties template template screws 1 Specifications are subject to change without notice 2 The Universal socket is fully compatible with power plugs in UK India Italy Denmark and the 2 prong Europlug 3 The Universal socket is partially compatible polarity is reversed with plugs in China Switzerland Israel and USA The Universal socket does
8. g Surface Features Feature Function 1 RC 3TB 3 button remote controls 2 Blank Insert Optional blank insert 3 Pass through Bushings 9 0mm split hole grommets 6 pass throughs 4 Pass through Bushings 12 5mm split hole grommets 2 pass throughs 5 Universal Power Sockets Power sockets for PCs Installing the TBUS 6W Table Connection Bus To install the TBUS 6W perform the following steps 1 Cut an opening in the table see section 5 1 2 Adjust the height of the connecting surface see section 5 2 3 Install the TBUS 6W in the cut out opening see section 5 3 4 Connect the cables see section 5 4 1 Some versions may not include tie holes Installing the TBUS 6W Table Connection Bus 5 1 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template on the surface of the table where you want to install the TBUS 6W 2 Attach the template to the table with the included screws 3 Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 4 not to scale Note The thickness of the table should be 3 inches or less 245 2mm gt 154 2mm Figure 4 Cutout Dimensions 4 Unscrew and remove the template from the surface of the table and clean the table surface Take care not to damage the table If needed you can download a full scale tem
9. plate from our Web site Kramer Electronics is not responsible for any damage caused to the table 1 At http www kramerelectronics com 6 KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the TBUS 6W Table Connection Bus 5 2 5 3 5 4 Adjusting the Height of the Connecting Surface If needed you can adjust the connecting surface to one of several possible heights to accommodate large or bulky cables By default the height is set to the second level from the top To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers Raise or lower the connecting surface to the required height insert the screws and tighten them in place Installing the TBUS 6W in the Cut Out Opening To install the TBUS 6W in the opening 1 2 Carefully insert the unit into the prepared opening Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit see Figure 2 Verify proper alignment of the unit before tightening the mounting screws Screw both mounting butterfly screws upward until they reach the table surface from underneath Tighten firmly Screw the locking butterfly screws downward until tight against the mounting bracket Connecting the Cables To connect the cables l Ze 3 Pass any cables through the bushings as needed Connect the power cables
10. r any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and lightindustry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and lightindustry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION B gt Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer
11. thorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removalor installation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILLNOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OFDAMAGES The liability of Kramer fo

Download Pdf Manuals

image

Related Search

Related Contents

Manual del propietario Multímetro RMS real Modelo    Kidde Fire Systems 45-N1230M-002 User's Manual  NanoPhotometer C40/N50/N60/NP80 User Guide  Samsung SCX-4300 用戶手冊  Sony SVS1313ZDZB Safety & Regulations Guide  VPCF11 Series  Chauvet 330SR Indoor Furnishings User Manual  

Copyright © All rights reserved.
Failed to retrieve file