1. 2013 BION TECHNOLOGIS is a brand of ONELED DE GMBH All rights reserved Subject to change Specifications may change without notice
2. min 2 95 in A min 10 mm 0 40 in 2 Cut out Drill a mounting hole with 115 mm 4 41 in into mounting surface as indicated 3 Connection and mounting f 115 mm 4 52 in GE TG gt Connect fixture line data line and power line according to installation instructions Press your fixture into your mounting hole The fixture will attach itself by spring mechanism 6 www biontechnologies com Commissioning 1 Wiring pureWhite pureColor Rot V Schwarz V Y 110 240VAC Braun L 2 Wiring RGB tunableWhite 110 220 VAC Ke ED ESS ESS EES SI f 110 220 VAC www biontechnologies com 7 E ZR NV we 3 Wiring to power supply PS 250 or PS 500 connecting fixture to board Leuchtenanschluss an Platine dimmable non dimmable dimmbar nicht dimmbar numbered wires nummerierte Adern 5 x05 mm 2x0 5 mm factory wired cable factory wired cable standardkabel vormontiert standardkabel vormontiert extend with verl ngern mit extend with verl ngern mit 5 x AWG 16 up to 82 ft min 2 x AWG 16 up to 82 ft min or oder or oder 5 x 1 5 mm max 25 m 2x 1 5 mm max 25m Wire Ader Wire Ader GND MINUS 1 36 VDC PLUS DMX 2 GND MINUS Aadr DMX 36 VDC PLUS Be sure numbered wire will be mounted in dedicated terminal Be sure you have read and understood the safety instructions in the user manual Stellen Sie sicher das die Ad
3. Powersupply external 36 VDC PowerConsumption Max 18W 00 Operating Temperature Range 20 C 40 C 4 F 104 F Lumen Maintenance L70 65 000 h 25 C 77 F 40000 h 40 C 1049F 00 LED Class a 2 LED produet 00 Housing Aluminum Heatsink Titan anodized nn Housing Color s ENEN Aluminium Titanium Black anodized anodized anodized Standard Fame Natural anodized Standard Titan anodized Black anodized Weg Bek Bbs 0 Installation Depth 63mm 249M 50000 Cutout d Diameter 115 mm 452in 0000 Ingress Protection IPO 4 www biontechnologies com Environment A indoor Warranty 24 Months ee CE FC Engineering Drawing 115 00 125 00 50 00 4 N MIN ne I 24 00 Hersteller manufacturer Produkt praduct BIEN Kategorie category TECHNOLOGIES Deckeneinbauleuchten Downlights www biontechnologies com 5 HV AR Mounting 1 Preparing your installation Before installing the fixture please ensure that the strength of the bearing surface at least 10 mm and is made of solid material The installation may not be in heat insulation material or highly combustible substances Check mounting surface for firmness and back venting of device The installation depth should be at least 75 mm to provide enough space for cable connection Please remove the label on surface before operating the fixture min 75 mm
4. pro Farbgruppe 1 2 DMX 2 GND MINUS max 15 tectum in sum per board 3 Aadr max 15 tectum gesamt pro Platine 4 5 DMX 36 VDC PLUS Be sure numbered wire will be mounted in dedicated terminal Be sure you have read and understood the safety instructions in the user manual Stellen Sie sicher das die Adernummer in der zugeh rigen Klemmennummer fest montiert ist Beachten Sie die Sicherheitshinweise in der Bedienungsanleitung Verkabelung Leuchten je Netzteilauslass PS 500 indoor Max 24 Leuchten 2x Leuchten per Anschlussblock PS 250 indoor Max 12 Leuchten 2x Leuchten per Anschlussblock 16 www biontechnologies com Wartung Pflege Ger t regelm ig mit einem feuchten Tuch reinigen Verwenden Sie ausschlie lich l sungsmittelfreie Reinigungsmittel und verwenden Sie keine Chemikalien Konformit t FEMCE Hersteller pura Bion Technologies IT a brand of oneled de GmbH Lindberghstrasse 15 YR ot ttds 86343 Koenigsbrunn Tel 49 0 8231 95787 0 Fax 49 0 8231 95787 29 www biontechnologies com info biontechnologies com YouTube http www youtube com BIONTECHNOLOGIES All rights reserved Subject to change Specifications may change without notice www biontechnologies com 17 Elm TECHNOLOGIES Lindberghstrasse 15 86343 Koenigsbrunn Tel 49 0 8231 95787 0 Fax 49 0 8231 95787 29 www biontechnologies com info biontechnologies com YouTube http www youtube com BIONTECHNOLOGIES
5. untersagt Der Hersteller bernimmt keine Haftung durch Sch den die durch Ver nderung unsachgem en Einsatz oder fehlerhafte Montage entstehen Ger t trocken lagern und vor Besch digung sch tzen 10 www biontechnologies com Lieferumfang Packen Sie alle Teile aus Pr fen Sie den Verpackungsinhalt auf sichtbare Transportsch den Pr fen Sie ob der Verpackungsinhalt vollst ndig ist Im Lieferumfang enthalten Deckeneinbaustrahler tectum m Original Bedienungsanleitung Wenn Sie Transportsch den oder Unstimmigkeiten zwischen dem hier angegebenen Lieferumfang und Verpackungsinhalt feststellen informieren Sie unverz glich Ihre Verkaufstelle www biontechnologies com 11 Technische Daten Abmessungen Durchmesser 125 mm 4 92 in H he 65 mm 2 56 in Leuchtentyp 4 o 0 pureWhite pureColor Farbtemperaturen pureWhite 2700 K 3000 K 3500 K 4000 K Projektbezogene Farbtemperaturen f r pureWhite m glich LED Farben pureColor Rot Gr n Blau Amber Projektbezogene LED Farben f r pureColor m glich Abstrahlwinkel 8 10 23 43 52 8 x 31 10 x 42 12 x 60 20 x 60 Tilt der CO Ebene 20 Lichtstrom 1176 Im pureColor Rot 571 Im pureColor Grun 961 Im pureColor Blau 413 Im pureColor Amber 478 Im Lichtquelle 9 LED s Farbwiedergabeindex RB LED Binning MacAdam Elipsen Binning 3 Dimmung Nicht dimmbar Dimmbar DMX 4 ccm j 1 Netzteil extern 36 VD
6. C 00 Wirkleistungsautnahme Max 18W 0 Sehutzklasse a Betriebstemperaturbreich 20 C 40 C 4 F H104 F 0000 Lebensdauer L70 65 000 h 25 C 77 F 40 000 h 40 C 104 F n LEDKase 1 Klasse 2 LED Produkt nn Geh ue Aluminium K hlk rper Titan eloxiert nn Geh usefarbe n EEEN Aluminium Titan Schwarz natur eloxiert eloxiert eloxiert Standard Rahmen Rahmen Natur eloxiert Standard Titan eloxiert Schwarz eloxiert GeWct QO6K SbS 0 Einbautiefe 63mm 249i 500 Leuchtenausschnitt Durchmesser 115 mm 4 52 in 00 12 www biontechnologies com Umgebung A indoor Gew hrleistung 24 Monate sm CE MFE Technische Zeichnung 125 00 50 00 115 00 TEENS N MIN ne I 24 00 Hersteller manufacturer Produkt praduct BIEN Kategorie category Deckeneinbauleuchten Downlights www biontechnologies com 13 Montage 1 Vorbereitungen Vor dem Einbau der Deckeneinbauleuchte achten Sie bitte darauf das die Starke der tragenden Fl che mindestens 10mm betragt und aus festem Material besteht Der Einbau darf nicht in W rmeisolierende oder leicht brennbare Stoffe erfolgen F r ausreichende Hinterl ftung ist bei der Montage zu sorgen Die Einbautiefe sollte mindestens 75 mm betragen um ausreichend Platz f r die Kabelf hrung zu haben Vor Inbetriebnahme der Leuchte entfernen Sie bitte den Hinweis Aufkleber auf der Leuchtenoberf
7. ES ls IN TECHNOLOGIES O CEM FC tectum m pureWhite pureColor Arm OR AA AL ue Q D VW N N A Ore mi X IVA IN JA Nr A Leli ANA IVM NMEN OS SA BEDIENUNGSANLEITUNG www biontechnologies com USER MANUAL tectum m pureWhite pureColor Safety Instructions Devices must be installed by qualified personnel in compliance with all pertaining regulations Always refer to the technical parameters in the data sheet All items are subject to technical modification Refer to the attached User Manual as a basis for correct use Consult circuit diagram for correct wiring Note Before attempting any work make sure device is separated from main power Protect device from moisture Make sure protection against line voltage shock is provided during installation We recommend securing the installation by RCD circuit breakers Note that adjacent parts or devices must be temperature proof up to 90 C Do not operate the fixture with inductive consumers fluorescent lamps gas discharge lamps ventilators etc in the same electric circuit Activation of inductive consumers can cause damage to the operating device Do not place heat insulation material on the fixture Mind the operating temperatures of the fixture according to the technical data sheet Before drilling the mounting holes take precautions not to harm or damage any power lines Do not solder cable strands Use cable strand sleeves inste
8. Fachpersonal in bereinstimmung mit allen geltenden Vorschriften erfolgen Beachten Sie immer die technischen Daten auf dem Datenblatt Technische nderungen vorbehalten Die beigef gte Gebrauchsanleitung ist Voraussetzung f r den ordnungsgem en Gebrauch Die Aderbelegung ist gem Schaltschema zu beachten Achtung Vor Beginn der Arbeiten ist die Netzleitung spannungsfrei zu schalten Ger t vor N sse sch tzen Der Schutz gegen elektrischen Schlag ist beim Einbau sicherzustellen Wir empfehlen die bauseitige Absicherung ber einen Fehlerstrom Schutzschalter Beim Einbau ist darauf zu achten dass benachbarte Bauteile einer Temperatur von 90 C standhalten Leuchte nicht gemeinsam mit induktiven Lasten Leuchtstofflampen Entladungslampen Ventilatoren usw im gleichen Stromkreis betreiben Beim Schalten induktiver Lasten k nnen Defekte an der Leuchte entstehen W rmed mmung darf nicht auf der Leuchte liegen Beim Einbau ist auf die in den technischen Daten angegebene Betriebstemperatur zu beachten Beim Bohren der Befestigungsl cher ist darauf zu achten dass die Netzleitungen nicht besch digt werden Litzendr hte d rfen nicht verl tet werden Es sind Aderendh lsen zu verwenden Spannungskennzeichnung auf dem Betriebsger t beachten Ein einwandfreier elektrischer bergang ist beim Anschlie en der Leuchte zu gew hrleisten Die Leuchte darf nicht ge ffnet werden Kein Gew hrleistungsfall Jegliche Ver nderung ist
9. ad Note and mind voltage label on the device Make sure flawless electrical connectivity is provided Connecting the lamp to the powered up device can cause damage to the lamp voids product warranty No modification allowed No liability will be assumed in case of damage incurred by alteration improper use or faulty installation 2 www biontechnologies com Scope of delivery Check completeness of supplied device immediately after receipt In delivery included Downlight tectum m User Manual If you detect any transportation damage or differencies between specified packing contents and your unpacked delivery please contact your dealer immediately www biontechnologies com 3 MP i Technical Data Dimensions Diameter 125 mm 4 92 in Height 65 mm 2 56 in Fixture Typ 4 o0 0 pureWhite pureColor Color Temperatures pureWhite 2700 K 3000 K 3500 K 4000 K Project specific color temperature for pureWhite available LED Colors pureColor Red Green Blue Amber Project specific colors for pureColor available Beam Angles 8 10 23 43 52 8 x 31 10 x 42 12 x 60 20 x 60 Tilt in CO plane 20 Luminous Flux 1176 Im pureColor Red 571 Im pureColor Green 961 Im pureColor Blue 413 Im pureColor Amber 478 Im Light Source 9 LED s Color Rendering Index R80 LED Binning MacAdam Ellipses Binning 3 0 Dimming Non dimmable Dimmable DMX Input Voltage
10. ernummer in der zugeh rigen Klemmennummer fest montiert ist Beachten Sie die Sicherheitshinweise in der Bedienungsanleitung to connect DMX us a RJ 45 plug refer to USITT DMX 512 Standard Distribution board Anschlussplatine PS 250 6 1 board 1 Platine PS 500 12 2 boards 2 Platinen max 10 tectum per terminal color 2 terminals per color max 10 tectum pro Farbgruppe 2 Klemmstellen pro Farbgruppe max 15 tectum in sum per board max 15 tectum gesamt pro Platine Max Fixtures per Feed PS 500 indoor Max 24 fixtures 2x fixtuers per connector block PS 250 indoor Max 12 fixtures 2x fixtuers per connector block 8 www biontechnologies com Maintenance Clean device from dirt and residue regularly Use solvent free cleaning agents only and do not employ aggressive chemicals or high pressure cleaner Operate device only after complete drying Conformity FEMCE Manufacturer pura Bion Technologies IT a brand of oneled de GmbH Lindberghstrasse 15 YR ot ttds 86343 Koenigsbrunn Tel 49 0 8231 95787 0 Fax 49 0 8231 95787 29 www biontechnologies com info biontechnologies com YouTube http www youtube com BIONTECHNOLOGIES All rights reserved Subject to change Specifications may change without notice www biontechnologies com 9 BEDIENUNGSANLEITUNG tectum m pureWhite pureColor Sicherheitshinweise Anschluss und Bedienung dieses Ger ts sollte ausschlie lich von qualifiziertem
11. l che min 75 mm min 2 95 in min 40 mm 0 40 in 2 Ausschnitt Q 115 mm 4 52 in Bohren Sie an Ihrem vorgesehenen Platz einen kreisrunden Ausschnitt 115 mm f r Ihre Leuchte 3 Anschluss und Befestigung Schlie en Sie Ihre Leuchte gem Verkabelungsschema an Dr cken Sie die Leuchte in den Ausschnitt diese fixiert sich beim Eindr ckvorgang selbst ndig duch den Federmechanismus 14 www biontechnologies com Inbetriebnahme 1 Verkabelung pureWhite pureColor Rot V 110 240VAC Braun L 2 Verkabelung RGB tunableWhite 110 220 VAC 110 220 VAC www biontechnologies com 15 3 Verkabelung an Netzteil PS 250 oder PS 500 connecting fixture to board to connect DMX us a RJ 45 plug Leuchtenanschluss an Platine refer to USITT DMX 512 Standard dimmable non dimmable dimmbar nicht dimmbar Distribution board Anschlussplatine numbered wires nummerierte Adern PS 250 6 1 board 1 Platine 5 x 0 5 mm 2x0 5 mm factory wired cable factory wired cable standardkabel vormontiert standardkabel vormontiert extend with verl ngern mit extend with verl ngern mit 5 x AWG 16 up to 82 ft min 2 x AWG 16 up to 82 ft min or oder or oder EE 5 x 1 5 mm max 25 m 2 x 1 5 mm max 25 m PS 500 12 2 boards 2 Platinen max 10 tectum per terminal color 2 terminals per color GND MINUS 4 36 VDC PLUS max 10 tectum pro Farbgruppe 2 Klemmstellen