Home
9821 printers.indd
Contents
1. The boiler has been overfilled Steam baffle missing or improperly installed Boiler cap missing or loose Boiler cap gasket missing or defective Cap is on collector dis penser bottle Dispensing valve loose Boiler not fully engaged in chassis Electrical power interrup tion Excessive deposits in boiler Steam baffle improperly inserted O ring worn or defective Solution Plug Distiller into appropriate outlet Make sure the boiler is properly placed fig E Wait about 30 minutes for the fan to start Plug Distiller into appropriate outlet Press Start button to restart Check fuses or circuit breakers or call an electrician Replace the carbon filter cup page 5 Clean the bottle page 5 DO NOT overfill boiler Fill to bottom of four tabs in boiler opening fig D Properly install steam baffle and steam baffle securing nut page 6 9 Tighten boiler cap Replace gasket Remove cap from bottle during distillation cycle Tighten dispensing valve Make sure the boiler is properly placed fig E Press Start button to restart Clean boiler page 9 Properly install steam baffle and steam baffle securing nut page 6 9 Replace o ring Il 12 13 15 16 DO NOT operate without water in the boiler Permanent damage may occur This Distiller requires no special care other than general cleaning page 9 and periodic filter cup r
2. have an unwanted taste or odor x Discard first gallon of distilled water as it may contain small harmless carbon fines Order replacement filters from the outlet where you purchased your distiller Collector Dispenser Bott Clean Boiler e Remove boiler by grasping handle and pulling it out of chassis fig C e Remove boiler cap by turning it counterclockwise fig D e Loosen steam baffle securing nut by turning counterclockwise and remove steam baffle fig D e Wash inside of boiler with soap and water e Rinse thoroughly Water should be drained through boiler spout IMPORTANT Wipe off all water deposits inside the Distiller chassis and on the outside of the boiler before each distillation cycle USING THE COUNTERTOP DISTILLER WARNING Never remove the boiler while the fan motor is running or TAN for 30 minutes after it stops Severe burns can result from boiling water or steam DO NOT change position or location of distiller while it is operating or cooling Operational FIGURE C f co maintenance m ia and replacement 0 g requirements are J essential for this product to perform as Collector Boiler Distiller Chassis aiertised Dispenser Bottle 1 Set Distiller on dry level well supported stable surface 2 Remove collector dispenser bottle 3 Remove boiler by grasping its handle and pulling it out of chassis 4 Remove
3. immerse power cord or Distiller in water or liquid DO NOT operate with a damaged cord or plug after a malfunction or if the Distiller has been damaged in any manner Return to an authorized service facility for examination and repair This Distiller is recommended for use with potable water only DO NOT attempt to make safe drinking water from non potable water sources DO NOT use briny sea water as this will damage certain compo nents and will void warranty Operate in a well ventilated area away from other heat sources Provide adequate air space at least 4 6 inches from walls or cabinets when in use DO NOT place on or near a hot gas or electric burner or in a heated oven DO NOT place store or stack anything on top of or against sides of Distiller while in operation TROUBLESHOOTING Problem Start button does not light up Start button lights up but fan does not start Distiller does not operate The distilled water has an unusual taste Steam appears inside chassis above boiler Water leaking from Distiller Water under boiler 10 Possible Cause Distiller is not plugged in Boiler is not fully engaged Fan delayed start system has not activated the fan Distiller is not plugged in Electrical power interruption Outlet is defective or fuse or circuit breaker has tripped The carbon filter is contaminated The collector dispenser bottle needs cleaning
4. is then collected in the GE Lexan polycarbonate collector dispenser bottle 6 Lexan is a Registered Trademark of General Electric Company This system was tested and certified by the Water Quality Association against WQA S 400 for the reduction of TDS Total Dissolved Solids It has the product water production rate of 1 gallon per 4 5 hours and has the product water storage capacity of 1 gallon Model 9000 Production rate 5 5 gallons per day Model Volts Hertz Watts North America 9033 120 VAC 60 Hz 750W FIGURE G DISTILLER MAINTENANCE WARNING Always be sure to unplug power cord from wall outlet before cleaning or servicing Distiller Cleaning Boiler Rinse the boiler before every distillation cycle with warm tap water to remove any loose residue Loosen securing nut and remove steam baffle fig D Half fill boiler with warm tap water agitate and discard the water The water should be drained through boiler spout Excessive deposits can cause malfunction As scale deposits build up use an approved cleaner such as KLEENWISE to remove this deposit White vinegar or automatic coffee pot cleaner can also be used DO NOT operate Distiller with cleaning solution in boiler Use a soft plastic or nylon scour ing pad if needed DO NOT use abrasive cleaners caustic acids steel wool pads or metal utensils Wipe outside of boiler tank with a soft cloth or sponge and mild soapy water IMPORTANT Wipe off all water deposits i
5. will go out and boiler will stop heating if electrical power is interrupted or stopped If this occurs press Start button again to restart the distillation cycle NOTE The cooling fan will not start immediately because of a delayed fan start up feature The fan will start once the boiler has reached a predetermined temperature approximately 30 to 40 minutes after starting the cycle WARNING To prevent personal injury burn and or scald injury A DO NOT remove boiler while Start button is illuminated or at any time when the boiler is hot Always unplug Distiller from wall outlet and allow boiler to cool completely before removing it from the Distiller at least 30 minutes DO NOT change position or location of Dis Distiller tiller while it is operating or Chassis cooling 13 Place prepared carbon filter cup into opening at the top of the collec tor dispenser bottle DO NOT install cap DAN onto bottle fig F 14 Replace the collector dispenser bottle fig F Make sure the dispensing valve is Boiler Start Button securely tightened
6. ST GALLON of distilled water as it may contain some harmless matter from manufacturing and or packaging 17 Rinse boiler thoroughly before refilling IMPORTANT Wipe off all water deposits inside the Distiller chassis and on the outside of the boiler before each distillation cycle NOTE The collector dispenser bottle will not fill completely The collec tor was designed to hold 1 gallon of water and allow additional space so that the carbon filter does not remain in contact with the distilled water Once distillation cycle is complete the water bottle may be placed in refrigerator and used to dispense the distilled water The filter cup may be left in or removed and stored in the refrigerator in a sealed plastic bag or other airtight container Secure cap onto the bottle to avoid spilling The cap must be opened slightly before dispensing water It is recommended that the bottle NOT be placed in a freezer as handle may become brittle and crack NOTE Approximately 5 ounces 150 ml of water will remain in boiler at the end of the distillation cycle This feature reduces scale deposits in the boiler WARNING To prevent personal injury or electric shock DO NOT immerse the Distiller its boiler its cord or plugs in water or other liquid Ficure B PREPARING FOR FIRST TIME USE Clean Collector Dispenser Bottle e Ensure the dispensing valve fig B is installed and tightened e Fill bottle approximately three fourths full with tap
7. WARRANTY REGISTRATION Please call 1 800 624 5836 to register this distiller OWNER S LIMITED WARRANTY Tuttnauer warrants to the original purchaser this product against defects in materials and workmanship excluding the disposable carbon filter and gasket for a period of one 1 year from the date of purchase Defects or failures due to shipping handling improper use or maintenance including abuse or neglect normal wear water condi tions accidents alterations or modifications or unauthorized repair are specifically excluded from this warranty No dealer distributor agent representative or other person is authorized to extend or expand this warranty Tuttnauer is not responsible or liable for personal injury property damage or incidental or consequential damages arising out of or in connection with the use or performance of the product or other damages with respect to loss of use or costs of removal instal lation or reinstallation Tuttnauer will at its option replace or repair the defective part s or distiller without charge provided the instrument is returned transportation prepaid to an authorized service facility Please enclose a letter describing the problem you experienced and copy of dated proof of purchase if possible This limited warranty does not guarantee uninterrupted service Repair or replace ment as provided under this warranty is the exclusive remedy of the purchaser This limited warranty is in l
8. boiler cap by turning it counterclockwise fig D 5 Loosen steam baffle securing nut by turning counterclockwise and remove steam baffle fig D Rinse boiler thoroughly before filling The water should be drained through boiler spout 7 Fill boiler with ordinary tap water to bottom of four tabs in boiler opening approximately 1 gallon 3 8 Liters These tabs indicate the MAXIMUM FILL POINT DO NOT OVERFILL fig D 8 Replace boiler cap by turning it clockwise until tight 9 Make sure gasket is installed on long end of steam baffle and that it is snug against flange fig D Insert long end of baffle flat side down into the boiler spout Turn securing nut clockwise onto spout aN until tight being careful to not cross thread IMPORTANT Wipe off all water deposits inside the Distiller chassis and on the outside of the boiler before each distillation cycle 6 Ficure D j Boiler Cap s hon p Steam Baffle Securing Nut gt e A Steam Baffle flat side Boiler Cap Gasket Pa Maximum Fill Point Boiler bottom of tabs 10 Slide boiler into chassis compartment and press firmly to ensure boiler is properly placed fig E To prevent personal injury or property damage the boiler must be fully engaged prior to start up 11 Plug power cord into a properly rated grounded outlet 12 Press Start button at base of boiler fig E Start button will illum inate when heating however the light
9. eplacement page 5 If servicing becomes necessary contact an authorized dealer or authorized service facility DO NOT attempt to repair Distiller yourself There are NO user serviceable parts See warranty for service details Unplug from wall outlet when not in use and before cleaning Allow to cool at least 30 minutes before cleaning Make sure collector dispenser bottle is properly placed with its cap removed for proper water collection DO NOT remove collector dispenser bottle while Distiller is operating DO NOT FILL BOILER TANK ABOVE THE MAXIMUM FILL POINT fig D DO NOT use appliance for other than intended use ELECTRIC CORD STATEMENT CAUTION Your Distiller has a short cord as a safety precaution to prevent injury or property damage resulting from pulling tripping or becoming entangled with the cord DO NOT allow children to be near Distiller without close adult supervision If you must use an extension cord with Distiller the cord must be arranged so that it will not drape or hang over the edge of a countertop or tabletop where it can be pulled on by children or tripped over To prevent electric shock injury or fire the electrical rating of the extension cord you use must be the same as or more than wattage of the Distiller wattage is indicated on bottom of Distiller Plug Distiller into rated voltage AC grounded electric outlet ONLY rated voltage found on bottom of product The cord ha
10. ieu of all other warranties expressed or implied including but not limited to any implied warranty of merchantability or fitness for a particular use or purpose This warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province Outside the United States a different warranty may apply For details please contact your authorized Tuttnauer distributor If your distiller fails to function properly or requires service please contact your autho rized distributor to arrange for service and or replacement parts Tuttnauer Co USA Ltd 25 Power Drive Hauppauge NY 11788 1 800 624 5836 2000 Purewise Printed in USA Form 9821 Rev 11 08 USE amp CARE GUIDE Model 9000 Countertop Steam Distiller See important safeguards on pages 2 and 3 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance instructions inthe literature accompanying the appliance A lightning bolt within an equilateral triangle is intended to alert user to risk of injury from electric shock Flame and steam vapor within an equilateral triangle is intended to alert user to risk of injury from boiling water and or escaping steam A IMPORTANT SAFEGUARDS A person who has not read and understood all operating and safety instructions is not
11. nside the Distiller chassis and on the outside of the boiler before each distillation cycle Cleaning Collector Dispenser Bottle See page 5 for cleaning and sanitizing instructions Replacing Carbon Filter Cup See page 5 for preparation and installation instructions Distiller Chassis Maintenance Outside surfaces may be cleaned with common non abrasive household glass or appliance cleaners or warm soapy water applied to a soft cloth or sponge The Distiller s cooling vents fig G should be vacuumed occasion ally or cleaned with a soft brush to remove dust and debris ra AET Cooling Vents IMPORTANT There are NO user serviceable parts inside Distiller Contact qualified service personnel for repair if troubleshooting tips fail page 10 settee Distiller Chassis Ficure F Filter Cup A Boiler Dispensing da Collector Dispenser Valve Bottle IMPORTANT The collector dispenser bottle must be properly placed with its cap removed and filter cup in place for proper water collection DO NOT remove collector dispenser bottle while Distiller is operating NOTE At the end of the distillation cycle about 4 5 hours Distiller will shut off automatically and Start light will go out The fan will continue to operate for a few minutes 15 Unplug cord from wall outlet when not in use 16 DISCARD FIR
12. qualified to operate this appliance When using this appliance always adhere to basic safety precautions including 10 READ ALL INSTRUCTIONS BEFORE USE FOR HOUSEHOLD USE ONLY Use INDOORS on a dry level well supported stable surface DO NOT operate in a moving vehicle DO NOT change position or location of Distiller while it is operating or cooling Water in the boiler is heated to boiling 212 F and can cause severe burns DO NOT remove collector dispenser bottle or boiler while Distiller is operating Boiling water or steam can cause severe burns Let cool at least 30 minutes after a cycle is finished before removing boiler cap DO NOT allow children to be near Distiller without close supervision Boiling water will scald if spilled on skin Warn other users of possible dangers from boiling water and or escaping steam DO NOT place near an edge of a surface where Distiller can be bumped or pulled down on someone DO NOT allow power cord or extension cord to hang over the edge of counter or contact hot surfaces A short power supply cord is provided to reduce risks resulting from becoming entangled in or tripping over a longer cord If an extension cord must be used its marked electrical rating must be at least as great as the electrical rating of the Distiller Electrical rating is found on bottom of Distiller To protect against fire electrical shock and injury to persons DO NOT
13. s a three prong plug which mates with a standard three prong grounded wall outlet DO NOT cut or remove third prong from plug If an adapter is used be sure adapter wire and wall outlet are grounded If there is any doubt as to whether the outlet is properly grounded check with a qualified electrician Unplug Distiller when not in use WARNING Never remove the boiler while the fan motor is running or for 30 minutes after it stops Severe burns can result from boiling water or steam DO NOT change position or location of distiller while it is operating or cooling SAVE THESE INSTRUCTIONS FIGURE A HOW IT WORKS This Distiller produces purified water by using the oldest most effective method of water treatment steam distillation When the Distiller is operating the water temperature rises to 212 F 100 C killing bacteria cysts and viruses that may be present As the boiling water 1 converts to steam 2 it rises and leaves behind dead microbes dissolved solids salts heavy metals and other substances Low boiling light gases that may be present are discharged through the gaseous vent 3 Steam is then cooled in the stainless steel condenser 4 turning it into high quality water Distilled water percolates through a final polishing coconut shell carbon filter 5 to enhance quality by adsorption of VOCs volatile organic compounds and
14. water e Add one or two drops of dish detergent e DO NOT install filter cup at this time e Seal bottle opening with cap e Shake vigorously and drain e Rinse thoroughly Sanitize Collector Dispenser Bottle e Add 6 ounces 180 ml of 3 percent hydrogen peroxide to bottle e Fill with hot distilled or tap water e DO NOT install the filter cup at this time e Seal bottle opening with cap e Shake vigorously and let stand for 20 minutes e Drain and rinse thoroughly Sterilize and Rinse Carbon Filter Cup Before installing fully immerse new filter cup in distilled water for about five minutes Then sterilize filter cup by fully immersing in boiling water for about five minutes Allow filter to cool before handling Pour 1 to 2 cups distilled water through filter cup to rinse away any small harmless carbon fines dust Water draining from the filter cup may contain black dust This is typical The carbon dust is formed as a result of production packaging and shipping of filter cup Um yY Bottle Cap Install Filter Cup Place sterilized filter cup into opening of collector dispenser bottle There is a label packed with replacement filter cups Write in installation date as a Filter Cup replacement reminder Replace Filter Cup The filter cup should be replaced every two months or after 60 80 gallons of water processed which Dispensing ever comes first Replace more often Valve should the distilled water begin to
Download Pdf Manuals
Related Search
Related Contents
KitchenAid KM25G0XWH5 User's Manual JJP Strings & Keys User Manual KTM 60 User's Manual カタログ デウォルト電動工具 取扱説明書 DC900K 36V充電式 振動/ドリル ISTRUZIONI D`USO - Amazon Web Services SDS Z50J FRONT FORK(φ27)取扱説明書 Copyright © All rights reserved.