Home

V680 RFID DeviceNet ID Slave V680-HAM42-DRT

image

Contents

1. V680 RFID OMRON DeviceNet ID Slave V680 HAM42 DRT DeviceNet Read and write up to 58 bytes of data DeviceNet makes information management at the production site simpler more flexible and more open Omron _V680 HAM42 MS I O DeviceNet ID Slave V680 HAM42 DRT The Antenna Cable is available in 2 m and 12 5 m lengths IP67 protection for FA environments PGE i V680 HSULI Lineup includes 1K 2K 8K and 32K ID Tags The wide lineup includes super compact ID Tags with an 8 mm diameter that can be embedded in metal as well as long life ID Tags capable of 10 billion accesses Access Up to 58 Bytes of Data Improve Communications Performance with the Master Unit You get improved tact time and simplified startup and maintenance V600 HAM42 DRT compatible Access Modes allow the application of existing programs Ba special function greatly reduces communications data with the Master Unit of the PLC for even easier doi Powerful Functions in a Compact Size Operating modes include 4 byte 26 byte and 58 byte Access Modes and a Noise Measurement Mode l The compact size of 65 x 65 x 65 mm reduces installation space 4 The DeviceNet ID Slave can communicate with ID Tags and Antennas that comply with ISO IEC 48000 3 ISO IEC 15693 to enable a wide variety of applications The V680 Antenna comes with a maximum cable length of 12 5 m allowin
2. 1 000 VAC 50 60 Hz for 1 minute between all terminals excluding the ground terminal and the case 10 to 150 Hz 0 2 mm double amplitude at 15 m s acceleration with 10 sweeps in X Y and Z directions for 8 minutes each 150 m s in X Y and Z directions 3 times each 18 times in total IEC 60529 IP20 Materials Polycarbonate PC resin ABS resin Weight Approx 150 g Mounting DIN Track Note For details refer to the User s Manual Cat No Z278 Operating Modes Symbol Description Maximum number of bytes accessible in ID Tag Words allocated in Master Unit 4CH 4 byte Access Mode Read 4 bytes Write 4 bytes IN 4 words OUT 4 words PLC inputs 64 points PLC outputs 64 points 16CH 26 byte Access Mode Read 26 bytes Write 26 bytes IN 16 words OUT 16 words PLC inputs 256 points PLC outputs 256 points 32CH 58 byte Access Mode Read 58 bytes Write 58 bytes IN 32 words OUT 32 words PLC inputs 512 points PLC outputs 512 points Note 1 The V600 compatible Trigger and Auto Modes can be used with the same 1 O settings and control methods that are used with the V600 HAM42 DRT 2 For details refer to the User s Manual Cat No Z278 Commands 4 byte 26 byte 58 byte Access Mode Reading READ Data in the ID Tag memory is read by specifying the memory address and the number of bytes to process The number of bytes can be specified using the Access Mode WRITE Data is written to the ID Tag by sp
3. 10 Read Write 5 0 to 55 0 mm axial deviation 10 flush mounted on metallic surface steel This document provides information mainly for selecting suitable models Please read the User s Manual Cat No Z278 carefully for information that the user must understand and accept before purchase including information on warranty limitations of liability and precautions OMRON Corporation Industrial Automation Company Sensing Devices Division H Q Industrial Sensors Division Shiokoji Horikawa Shimogyo ku Kyoto 600 8530 Japan Tel 81 75 344 7022 Fax 81 75 344 7107 Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 81 1 0 Fax 49 7032 811 199 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 301 1 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China OMRON Industrial Automation Global www ia omron com Tel 86 21 5037 2222 Fax 86 21 5037 2200 Authorized Distributor In the interest of product improvement specifications are subject to change without notice Cat No Q161 E1 01 Printed in Japan 0308 0
4. 2 Read 5 0 to 25 0 mm axial deviation 10 Read 5 0 to 25 0 mm axial deviation 10 flush mounted on metallic surface steel Write 1 0 to 14 0 mm axial deviation 2 Write 5 0 to 20 0 mm axial deviation 10 Write 5 0 to 20 0 mm axial deviation 10 o Read 5 0 to 25 0 mm axial deviation 10 Read 5 0 to 42 0 mm axial deviation 10 V680 D1KP66T SP Read Write 1 0 to 15 0 mm axial deviation 2 Write 5 0 to 20 0 mm axial deviation 10 Write 5 0 to 37 0 mm axial deviation 10 V680 D2KF52M Read Write 0 5 to 5 5 mm axial deviation 2 Read Write 0 5 to 8 0 mm axial deviation 2 Read Write 0 5 to 9 5 mm axial deviation 10 V680 D2KF52M ere l l E an Read Write 0 5 to 3 5 mm axial deviation 2 Read Write 0 5 to 3 0 mm axial deviation 2 aa 2 Kbyte embedded in metallic surface steel memory V680 D2KF67 Read Write 1 0 to 17 0 mm axial deviation 2 Read Write 7 0 to 30 0 mm axial deviation 10 Read Write 5 0 to 42 0 mm axial deviation 10 V680 D2KF67M oa eee ee ae Read Write 1 0 to 16 0 mm axial deviation 2 Read Write 6 0 to 25 0 mm axial deviation 10 Read Write 5 0 to 25 0 mm axial deviation 10 flush mounted on metallic surface steel V680 D8KF68 D32KF68 Read Write 5 0 to 45 0 mm axial deviation 10 Read Write 5 0 to 75 0 mm axial deviation 10 8 32 Kbyte V680 D8KF68 D32KF68 memory Special attachment provided Read Write 5 0 to 35 0 mm axial deviation
5. 3C 0308 C
6. ecifying the memory address number of bytes to process and the data The number of bytes can be specified using the Access Mode Writing BIT SET Previously specified bits i e bits that are turned ON are turned ON in the ID Tag address specified for BIT SET BIT CLEAR Previously specified bits i e bits that are turned ON are turned OFF in the ID Tag address specified for BIT CLEAR DATA FILL The specified continuous memory addresses in the ID Tag are filled with the same data Transmission Distance Specifications Unit mm DT Amplifier V680 HAM42 DRT a Antenna V680 HS51 V680 HS52 V680 HS63 V680 HS65 V680 D1KP52MT Read 0 5 to 6 5 mm axial deviation 2 Read 0 5 to 9 0 mm axial deviation 2 Read 0 5 to 12 0 mm axial deviation 2 Write 0 5 to 6 0 mm axial deviation 2 Write 0 5 to 8 5 mm axial deviation 2 Write 0 5 to 9 5 mm axial deviation 2 V680 D1KP52MT Read 0 5 to 3 5 mm axial deviation 2 Read 0 5 to 4 5 mm axial deviation 2 embedded in metallic surface steel Write 0 5 to 3 0 mm axial deviation 2 Write 0 5 to 4 0 mm axial deviation 2 1 Kbyte o Read 5 0 to 30 0 mm axial deviation 10 Read 5 0 to 47 0 mm axial deviation 10 V680 D1KP66T saz Read Write 1 0 to 17 0 mm axial deviation 2 memory Write 5 0 to 25 0 mm axial deviation 10 Write 5 0 to 42 0 mm axial deviation 10 V680 D1KP66MT Read 1 0 to 16 0 mm axial deviation
7. g it to be installed in ound away from the control panel Take the V680 Overseas j gt The V680 complies with international standards and radio wave regulations Radio wave regulation compliance is applicable to Japan Europe the U S As and Ganada Radio wave regulation compliance for China Taiwan South Korea and Southeast Asia is pending al reaLrzing j Ordering Information Appearance Item Model Connectable Antennas 65 x 65 x 65 mm excluding protrusions Size One channel V680 HS V680 HAM42 DRT Model NEW Note For applicable V680 Antennas and ID Tags and for more information on the V680 HAM42 DRT refer to the Datasheet Cat No Q160 and the User s Manual Cat No Z278 Ratings and Performance V680 HAM42 DRT Supply voltage 24 VDC 15 to 10 including 10 ripple p p Power consumption 4 W max Current consumption of 200 mA max at power supply voltage of 24 VDC Ambient operating temperature 10 to 55 C with no icing Ambient storage temperature Ambient operating humidity 25 to 65 C with no icing 25 to 85 with no condensation ambient operating temperature is 40 C max at humidity of 85 Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection 20 MQ min at 500 VDC between all terminals excluding the ground terminal and the case

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instruções VEGADIS 61  procedimientos para la correcta instalación de  GBC 45440 binding cover  Les frontières de l`entreprise  BHB pos-station V100 d  Toshiba Qosmio G15  BENDIX 03-F-01 User's Manual  Ubiquiti Networks UAP-PRO-3 WLAN access point  LevelOne GSW-1601TX User's Manual  SAUTER flexotron®800 User program Heating  

Copyright © All rights reserved.
Failed to retrieve file