Home

USER`s MANUAL

image

Contents

1. HAMAK solar Solar Power Storage System Supporting AC DC output and auto utility transfer HA WCB1K24 WCB2K48 WCB3K48 USER s MANUAL Before operating this unit please read this manual thoroughly and retain it for future reference JN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE PLEASE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL AN WARNING TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE LIMITATIONS ON USE THIS EQUIPMENT IS NOT INTENDED FOR USE WITH LIFE SUPPORT EQUIPMENT OR OTHER MEDICAL EQUIPMENT OR DEVICES For safe and optimum performance the Solar Power Storage System must be used properly Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements If you have technical problems first contact your installer For more about HAMAK products or any necessary assistance please contact us Service Contact Information lal A Wi A K TECHNOLOGY L LC Global Operation Center 15E North st Dover DE19907 Delaware USA 7F 7 No 925 Sec 4 Taiwan Blvd Xitun Dist Taichung City 407 Taiwan R O C www hamak com tw mail hamak hamak tech com Tel 886 4 23582908 Fax 886 4 23586263 HAMAK solar LIMITATION OF LIABILITY THIS PUBLICATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT N
2. HA WCB2K48 HA WCB3K48 This manual must be followed during installation and maintenance To reduce the risk of personal injury and to ensure the safe installation and operation of the product you must carefully read and follow all instructions cautions and warnings in this manual Product Introduction HA WCEB series of Solar Power Storage System is designed for the rated voltage 24Vdc model HA WCB1K24 only 48Vdc system built in rechargeable and or VRLA valve regulated lead acid batteries connecting with solar panel which located in outdoor to generate the power Just plug in the connector from panels then save the solar energy in storage system To ensure there has continuously power supply to loads it will automatically transfer to utility power when batteries in low condition Features e DC output voltage 24V or 48V AC output voltage 110V or 220V Max e Built in Used in high efficiency deep cycle gel battery e MPPT control system e Battery reverses polarity battery over discharge overload protection e Built in automatically transfer to utility power to loads when run out of battery HAMAK solar Product Description Front Panel or W N HAMAK Solar CHARGER STATUS BATTERY CAPACITY Walking Charger Box VOLTAGE METER ON amp OHI PV f S mio ALARM 8 POWER Switch AC DC power output ON OFF PV Green LED lights when charger gt please refer to P2 ALARM Showing load co
3. OT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTIBILITY FITNESS FOR ANY PARTICULAR PURPOSE OR NON INFRINGEMENT OF THE THIRD PARTY S RIGHT THIS PUBLICATION COULD INCLUDE TECHNICAL INACCUACIES OR TYPOGRAPHICAL ERRORS CHANGES ARE ADDED TO THE INFORMATION HEREIN AT ANY TIME FOR THE IMPROVEMENTS OF THIS PUBLICATION AND OR THE CORRESPONDING PRODUCT S DISCLAIMER OF WARRANTY IN NO EVENT SHALL THE SUPPLIER BE LIABLBE TO ANY PARTY OR ANY PERSON EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT FOR THE CASES INCLUDING BUT NOT LIMITED TO THE FOLLOWINGS ANY DAMAGE OR LOSS INCLUDING BUT WITHOUT LIMITATION DIRECT OR INDIRECT SPECIAL CONSEQUENTIAL OR EXEMPLARY ARISING OUT OF OR RELATING TO THE PRODUCT PERSONAL INJURY OR ANY DAMAGE CAUSED BY INAPPROPRIATE USE OR NEGLIGENT OPERATION OF THE USER UNAUTHORIZED DISASSEMBLE REPAIR OR MODIFICATION OF THE PRODUCT BY THE USER ANY PROBLEM CONSEQUENTIAL INCONVENIENCE OR LOSS OR DAMAGE ARISING OUT OF THE SYSTEM COMBINED WITH THE DEVICES OF THE THIRD PARTY ANY CLAIM OR ACTION FOR DAMAGES BROUGHT BY ANY PERSON OR ORGANIZATION BEING A PHOTOGENIC SUBJECT DUE TO VIOLATION OF PRIVACY WITH THE RESULT OF THAT SURVEILLANCE CAMERA S PICTURE INCLUDING SAVED DATA FOR SOME REASON BECOMES PUBLIC OR IS USED FOR THE PURPOSE OTHER THAN SURVEILLANCE HAMAK solar IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions for the following products HA WCB1K24
4. he buzzer 25 times in a row DC load will be off directly And the system will transfer AC power from battery supply to utility supply automatically Load status display Alarm Indicator In the deeply discharge or load short circuit overload condition output load of the controller will turn off The indicator will showing below Normal operation Discharge protection Overload or short circuit ALARM OFF ALARM ON ALARM Flashing AC power status display pointer voltmeter When the POWER switch ON the voltage meter can immediately display the current value of the output AC voltage pS _ O9 a Normal operation Overload or battery no power POWER switch On POWER switch On Trouble Shooting HAMAK solar If you have trouble operating the camera first refer to the following table If the problem persists contact the supplier for support for more information Symptom Possible Cause Possible Remedy No power from battery ALARM indicator red light on Load overflow or short circuit ALARM indicator Flashing Battery voltage too high or too low HI amp ALARM indicator light on Battery no power or overload Voltmeter no reply ALARM indicator Battery has low capacity red light on Solar module is error or polarity reversed PV POWER indicator green light off Replace batteries Used in charging function to charge to the battery by itself and load wi
5. ll re open when power return to MID Closes all loads and eliminates the breakdown then load terminal open automatically in one minute later To check if any voltage from battery if not means the controller damaged Replace the battery Used in charging function to charge to the battery by itself Remove AC output load Check whether the battery had been damaged Check whether the load Short circuit causing over discharge Using the charging function to charge again Check Solar module and the wiring and correct the fault connection Battery a Buzzing l Battery polarity reversed Correct reversed reverse continuously HAMAK solar Battery replacement To replace the batteries by professional person Do not change battery size to the smaller or larger Pay attention on battery polarity the box were designed with protection on battery polarity and buzzer reminding will come out when battery polarity Used in re chargeable and or VRLA valve regulated lead acid battery Safety recommendations Batteries store a large amount of energy Never short circuit a battery under all circumstances We recommend connecting a fuse slow acting type according to the nominal controller current directly to the battery terminal Batteries can produce flammable gases Avoid making sparks using fire or any naked flame Make sure that the battery room is ventilated Avoid touching or short circuiting
6. ndition please refer to P2 BATTERY CAPACITY Indicate battery capacity please refer to P2 VOLTAGE METER To measure AC output voltage Back Panel A UW N Be Py INPUT oS OUTPUT ar _ ey eee Solar power input DC power output AC power 220V or 110V input AC power 220V or 110V output HAMAK solar Operation Pre startup Procedures To avoid the occurrence of sparks and the risk of electric shock please confirm the power is switch off before plug in Double check all wiring connections well Using a digital voltmeter DVM or standard voltmeter verify battery voltage Confirm the voltage is correct confirm the polarity The components are close together and carry hazardous voltages Use AAN appropriate care to avoid the risk of electric shock or equipment damage i Incorrect battery polarity will damage the inverter Excessive battery voltage also may damage the inverter This damage is not covered by the warranty Operating Locating the solar panels in outdoor without shadow and connecting to solar power input in back panel As long as the power switch on AC 220V AC 110V optional and 24Vdc model HA WCB1K24 only 48Vdc power can be output The battery power condition is monitored all the time after you connected the battery The system only need 10mA power to maintain system s operation when switch off The power will be transferred to utility power automa
7. tically to support the power to loads when run out of battery and transferred back to battery s power when battery s available capacity over 20 Display function The controller has 5 LED indicators and one alarm to offer information Under normal operation the controller would display charging status battery capacity state and error functions When capacity getting change in battery the light and buzzer will come out to display condition HAMAK solar Charge status PV indicator Display charge status from solar panel to battery the indicator will showing below Charging PV light on Un charge PV light off PV power supply PV power does not supply Battery capacity level HI MID LOW indicator Display Battery capacity level the indicator will showing below gt 75 25 75 lt 25 The various LED indicator meaning estimated value from battery s available capacity such as 25 75 meaning capacity of the battery s current situation Buzzer warning The Sound signal from internal Buzzer for battery capacity warning the indicator will showing below Buzzer once Buzzer 3 times Buzzer 25 times a e High Capacity Mid Capacity Low Capacity Discharge Protection HAMAK solar When the battery is discharged the battery capacity changes from high to low by time the system will make a prompt buzzer signal When the battery capacity is less than 10 discharge protection will be activated 1 minute later after t
8. wires or terminals Be aware that the voltages on specific terminals or wires can be up to double the battery voltage Use isolated tools stand on dry ground and keep your hands dry Keep children away from batteries and the charge controller Please observe the safety recommendations of the battery manufacturer If in doubt consult your dealer or installer HAMAK solar Technical Data Serjes HA WCB Model No HA WCB1K24 HA WCB2K48 HA WCB3K48 voltage of solar panels 24V 100AH 48V 100AH 48V 200AH Battery rated voltage capacity 30 150Vdc 60 150Vdc MPPT 30 120Vdc 60 120Vde Max current of solar panels BOA 2400W 3000W Max input power 1200W AC max output power 1000W 2000W 3000W AC output operating time 1 5 hours 1 5 hours 2 hours DC max output power 240W 480W 6 5 hours 13hours DC output operating time 6 5 hours AC output voltage optional 110Vac 220Vac AC output frequency optional 50HZ 60HZ DC output voltage 48Vdc Discharge voltage 45Vdc Floating voltage 56Vdc Start city power voltage 45Vdc City power off voltage 48Vdc Protection Over load Battery polarity Battery over charge and over discharge Over temperature Operating temperature 0 40 C 20 50 C Length Width Height 690 520 500 500 520 950 620 520 950 IP Rating IP44 Storage temperature Technical date is subject to change without prior notice