ACTIVE 5 USER MANUAL
Contents
1. USER MANUAL O EG Br eae Lee ES EI Ca Go E j ACTIVE 5 C031 065 Issue 2 C 8 K Systems Ltd www ukpanels com THE ACTIVE 5 USER INSTRUCTIONS DATE FEB 1997 1 0 SETTING 1 1 FULL SET To start the exit procedure ensure all alarmed zones are clear and enter your four digit user code the speaker will emit a steady sound and the exit time will start Leave the building by the approved exit route and close the final exit door Wait outside the door until the speaker has stopped to indicate that the panel has armed The DAY LED will now be extinguished If however you need to set the system by using a terminator button or lock then operate from the outside of the system now If any zones are in fault the speaker will give a pulsed tone and the LED for that zone will be lit Return to the panel and press the key or enter the user code to abort the exit procedure Investigate the fault and correct if possible then start the exit procedure again If any zone on the exit route is open door open or detector tripped then the speaker will give a pulsed tone on exit but should go to a steady tone when the zone closes If you are unable to correct the fault contact your Installer If you do not complete the exit procedure before the exit time runs out an internal alarm will occur Enter your user code to stop the alarm See section 3 4 to reset the system 1 2 NIGHT SET Usually when you go to
2. example we will change user code 1 to 4567 You would enter lt CODE gt 91 4567 4 3 REVIEWING THE ALARM LOGS The logs are organised as SET and UNSET events All events are recorded The first alarm is shown by the relevant LED being lit continuously Subseguent alarms are shown by a fast pulse of the zone LED Any zones isolated are shown by a slow pulse ofthe zone LED The speaker will sound whilst viewing the SET logs but will be silent whilst viewing the UNSET logs Pressing the key will change between viewing the SET and UNSET logs This may be done at any time The log review will automatically end after 15 seconds if no keys are pressed Enter the four digit user code the speaker will emit a steady sound and the exit time start Press the key followed by the 9 key then press the 3 key The log routine will start viewing DAY 1 SET Press the key to finish You should test your system at regular intervals to aid this a walk test mode is prov ided You are allowed to test all ALARM devices DO NOT TEST ANY PERSONAL ATTACK BUTTONS Enter the four digit user code the speaker will emit a steady sound and the exit time start Press the key followed by the 9 key then press the 4 key The speaker will emit a low level steady tone As you test each device the internal sounder will give a loud pulsing tone to indicate the correct operation of that device The zone number LED will light When the device test is over
3. bed Start the exit procedure as for full set as above Then press the key followed by the 0 key The speaker will change to a lower pitched tone and the LED s for any zones programmed to be isolated in night set will flash The programmed Night set exit time will be selected and the exit procedure will continue If your system does not allow Night set an error tone will sound and the exit procedure will be aborted Again ifthe panel sets the DAY LED will extinguish 1 3 HOME SET If you want to set during the evening Start the exit procedure as for full set as above Then press the key followed by the 6 key The speaker will change to a lower pitched tone and the LED s for any zones programmed to be isolated in home set will flash The programmed night set exit time will be selected and the exit procedure will continue If your system does not allow home set an error tone will sound and the exit procedure will be aborted Again the DAY LED will extinguish 1 4 MANUAL ISOLATION Start the chosen exit procedure as above Then press the key followed by the zone number you reguire to isolate If more than one zone is reguired then press the button followed by the next zone number and so on until you have completed your choice If the zone is isolated the LED for the required zone will flash and the exit procedure will continue If you hear an error tone dah dah then the required zone may not be programmed for you to isolate Contact y
4. our Installer with regards to making this zone Isolate permit 2 0 UNSETTING Enter by your usual route the Speaker will begin to sound Do not stop go directly to the keypad Enter the four digit code the speaker will stop and the control panel will return to the DAY mode If the exit time has less than 10 seconds remaining the speaker will emit a quick pulsing sound to indicate HURRY UP 3 0 FAULTS 3 1 TAMPER FAULTS DURING AN UNSET PERIOD DAY MODE A tamper fault during the day is indicated by the internal speaker and the tamper LED Enter your four digit user code to stop the speaker the speaker will now change to a low level two tone alternating sound to indicate that there is a RESET REQUIRED Press the key to reset the system 3 2 ALARMS DURING THE SET PERIOD Enter your four digit user code to unset the system The LED display will indicate which zone s caused the alarm See section 3 4 to reset the panel 3 3 PERSONAL ATTACK ALARMS Enter your four digit user code to stop the speaker Reset the personal attack button with the key provided if needed See section 3 4 to reset the system www ukpanels com 3 4 RESETTING THE SYSTEM To reset the panel enter your user code The speaker will emit a low level two tone alternating Dee dah sound to indicate that there is a RESET REQUIRED Press the key to reset the panel Ifthe reset is allowed an accept tone will be given the LEDs for the zones in alarm will go o
5. the sounder will stop and the zone LED will go out The speaker will emit a low level steady tone as before Report any faults to your Installer Press the key to finish www ukpanels com IMPORTANT If you have any problem with your system or any difficulty understanding it s operation please contact your Alarm Installer immediately They will be pleased to help The following is given so a record of your zone configurations can be made simply fill in where each zone is located in your premises Also you can fill in any relevant contact numbers INSTALLER MOBILE NIGHTNO KEYHOLDER1 KEYHOLDER 2 EEE oe li CE his product should only be used for domestic commercial and light industrial use only C amp K Systems Ltd Unit 24 Walkers Road North Moons Moat Industrial Estate A Redditch NUR E Worcs DATIONAL eer eae B98 9HE 1309002 acca THE BRITISH SECURITY Tel 44 0 1527 68111 saal INDUSTRY ASSOCIATION Fax 44 0 1527 68222 BS EN ISO No 9002 1994 Technical Support 0345 660533 9am 5pm weekdays Certificate No 0944 Local rate call only UK Only www ukpanels com
6. ut and the panel will return to the DAY mode If the reset is not allowed an error tone will be given the LEDs will still indicate the alarm state Call your alarm company to complete the reset You will not be able to set your system again until a reset has been completed NOTE If an internal speaker is not fitted in your control panel then the tones given are limited and may not relate to the above information Contact your Installer regarding the fitting of a 16 ohm extension speaker 4 0 USER OPTIONS 4 1 AUTO TEST Enter your four digit user code the speaker will emit a steady sound and the exit time start Press the key followed by the 9 key The exit tone will stop and all the LEDs will light After the 10 Second LED test the internal speaker bell and strobe will each operate for 5 seconds the control will then emit an accept tone and revert to the DAY mode You may end the test at any time by pressing the key 4 2 CHANGING THE USER CODE Enter your four digit user code the speaker will emit a steady sound and the exit time w ill start Press the key followed by the 9 key then press the 1 key 4 LEDs will now come on to indicate a new 4 digit code is reguired Enter your new code As you press each key one LED will go out If your new code is allowed an accept tone will be given If the new code is barred an error tone will be given and your old code will still be valid Start again and enter a different four digit code As an