1. NOTICE Damage Cables with finely stranded copper conductors with a minimum cross section of 0 75 mm 18 AWG and a maximum cross section of 2 5 mm 14 AWG must be used for the supply voltage You must adhere to the following torques at the connector Screw connection of terminal blocks 0 22 Nm minimal to 0 25 Nm maximum Screw flange 0 3 Nm maximum Use the following procedure to connect the device to the supply volt age 1 Strip approx 30 mm 1 181 off the outer cable sheath and ap prox 5 mm 0 197 off the wires 2 Fit the wires with wire end ferrules and connect the wires to the socket strip 3 Plug the socket strip onto pin strip X1 4 Secure the socket strip in place with a screw type locking to prevent it from slipping out English Grounding The grounding is performed depending on the type of device with a slip on sleeve noiseless ground functional earth ground or a ring ca ble lug protective ground NOTICE Damage A separate copper conductor must always be provided for the ground ing The conductor must have a minimum cross section of 1 5 mm 16 AWG and must be kept as short as possible You must adhere to a maximum torque of 1 Nm at an protective grounding on the threaded bolt Al Strip approx 5 mm 0 197 off the wires 2 Fit the stripped wires depending on the type of device with a slip on sleeve or a ring cable lug 3 Plug the slip on sleeve on the flat
2. tab or mount the ring cable lug with the nut to the threaded bolt BT104XiT 320 mm 12 598 296 mm 11 654 4 5 mm 0 177 1 457 426 mm 16 772 1 457 450 mm 17 717 A Montageausschnitt Panel cutout B Frontplatte Front panel
3. S TRON electronic GmbH Kurze Stra e 29 D 70794 Filderstadt Tel 0049 711 77098 0 Fax 0049 711 77098 305 E Mail doku suetron de Internet www suetron de Touch Panel BT104XiT INSTALLATIONSANWEISUNG INSTALLATION INSTRUCTIONS 80860 133 Version 1 Copyright by S TRON electronic GmbH Wichtige Hinweise Die abgebildeten Zeichnungen entsprechen nicht der Originalgr e und k nnen somit nicht als Bohrschablone verwendet werden Beachten Sie unbedingt auch die weiterf hrenden Informationen im Anwenderhandbuch unter www suetron de handbuch gt Montage Q ACHTUNG Besch digung Beim Einbau m ssen Sie umlaufend einen Freiraum von mindestens 30 mm ber cksichtigen um eine ausreichende Luftzirkulation zu ge w hrleisten Beachten Sie bei horizontalem Einbau des Bedienger ts dass es durch zus tzliche W rmequellen unterhalb des Bedienger ts zu einem Hitzestau kommen kann Sorgen Sie f r eine ausreichende W rmeableitung Beachten Sie f r den Betrieb des Ger ts den zul ssigen Temperatur bereich der in den technischen Daten im Anwenderhandbuch angege ben ist O ACHTUNG Besch digung Deutsch ACHTUNG Besch digung O Um die angegebene Schutzart zu gew hrleisten m ssen Sie darauf achten dass die Dichtung eben auf der Einbaufl che aufliegt und die Sechskantmuttern mit einem Drehmoment von maximal 1 Nm gleich m ig angezogen sind Das Ger t e
4. V Versorgungsspannung 24 V GEFAHR Gef hrliche Ber hrungsspannung In elektrischen Anlagen k nnen f r Menschen gef hrliche Spannungen auftreten Bei Ber hrung von spannungsf hrenden Teilen besteht die Gefahr eines Stromschlags ACHTUNG Besch digung F r die Versorgungsspannung m ssen Sie ein Kabel mit feindr htigen Kupferadern mit einem Mindestquerschnitt von 0 75 mm und einem maximalen Querschnitt von 2 5 mm verwenden Am Steckverbinder m ssen Sie folgende Drehmomente einhalten Schraubanschluss der Klemmen 0 22 Nm minimal bis 0 25 Nm ma ximal Schraubflansch 0 3 Nm maximal Beim Anschluss der Versorgungsspannung gehen Sie wie folgt vor Z Isolieren Sie den Au enmantel des Kabels ca 30 mm und die Adern ca 5 mm ab 2 Versehen Sie die Adern mit Aderendh lsen und schlie en Sie die Adern an die Buchsenleiste an 3 Stecken Sie die Buchsenleiste auf die Stiftleiste X1 am Bedien ger t 4 Sichern Sie die Buchsenleiste durch die Schraubverriegelung gegen Herausrutschen Erdung Die Erdung wird abh ngig vom Ger tetyp mit einer Flachsteckh lse fremdspannungsarme Erde Funktionserde oder einem Ringkabel schuh Schutzerde durchgef hrt ACHTUNG Besch digung F r die Erdung m ssen Sie eine getrennte Kupferleitung vorsehen Die Leitung muss einen Mindestquerschnitt von 1 5 mm aufweisen und so kurz wie m glich ausgef hrt sein Bei einer Schutzerdung am Gewind
5. ebolzen m ssen Sie ein maximales Drehmoment von 1 Nm einhalten 1 Isolieren Sie die Leitung ca 5 mm ab Versehen Sie die abisolierte Leitung je nach Ger tetyp entwe der mit einer Flachsteckh lse oder mit einem Ringkabelschuh 3 Stecken Sie die Flachsteckh lse auf die Flachsteckzunge oder befestigen Sie den Ringkabelschuh mit der Mutter am Gewin debolzen English Important Notes The shown drawings do not correspond to the original size and there fore can not be used as a drilling template Please note also the detailed information in the user manual at www suetron de en manual Mounting the Device C NOTICE Damage When installing the device leave a gap of at least 30 mm 1 181 around the device to ensure sufficient air circulation NOTICE Damage When the operating device is installed horizontally please note that ad ditional sources of heat beneath the operating device may result in heat accumulation Make sure to allow sufficient heat dissipation Comply with the allowable temperature range listed in the technical data for the use of the operating device NOTICE Damage To maintain the specified degree of protection make sure the seal is evenly seated on the installation surface and the hexagon nuts are tightened uniformly Ensure that the maximum torque of 1 Nm is not exceeded The operating device can be easily and quickly mounted from the rear of t
6. he operating device A panel thickness of approx 1 mm to 6 mm 0 039 to 0 236 is permitted for proper mounting 1 Transmit the mounting cutout and the centers of the drillings to the mounting plate Cut out the rectangle from the mounting plate Drill the holes with the given diameter Remove the burrs from the cutting edges and drillings Insert the operating device from the front through the mounting cutout Fasten the operating device using M4 screws washers and hexagonal nuts Supply Voltage The supply voltage is supplied via pin strip X1 A suitable socket strip is supplied Refer to the technical data for the permissible supply voltage of the op erating device DFtob o gt The device has reverse polarity protection In case of wrong polarity J the device will not operate e This is a protection class device For safe operation safety extra low A voltage SELV in accordance with DIN EN 61131 must be used for the supply voltage Connector in the operating device 3 pin pin strip Pin assignment supply voltage Pin Designation Function 1 CO Noiseless ground functional Si earth ground FE 2 DV Supply voltage 0 V GND 24 V Supply voltage 24 V DANGER Hazardous voltages Hazardous voltages can exist inside electrical installations that can pose a danger to humans Coming in contact with live parts may result in electric shock
7. rm glicht Ihnen eine schnelle und einfache Montage von der Ger ter ckseite F r den ordnungsgem en Einbau sind Wand st rken von ca 1 mm bis 6 mm zul ssig 1 bertragen Sie den Montageausschnitt und die Mittelpunkte der Bohrl cher auf die Montagefl che 2 Schneiden Sie diesen Montageausschnitt aus der Montagefl che 3 Bohren Sie die L cher mit dem angegebenen Durchmesser 4 Entgraten Sie die Kanten des Montageausschnitts und die Bohrl cher Deutsch 5 Schieben Sie das Ger t von vorne durch den Montageaus schnitt 6 Befestigen Sie das Ger t mit M4 Schrauben Unterlegscheiben und Sechskantmuttern Versorgungsspannung Die Versorgungsspannung wird ber die Stiftleiste X1 zugef hrt Die geeignete Buchsenleiste ist im Lieferumfang enthalten Die zul ssige Versorgungsspannung f r das Bedienger t entnehmen Sie den technischen Daten Das Ger t verf gt ber einen Verpolschutz Bei falscher Polung wird L Al das Ger t nicht in Betrieb gesetzt P Dieses Ger t ist ein Betriebsmittel der Schutzklasse I F r einen siche 1 ren Betrieb m ssen Sie eine Schutzkleinspannung SELV entspre chend DIN EN 61131 f r die Versorgungsspannung verwenden Steckverbinder im Bedienger t 3 polige Stiftleiste Steckerbelegung Versorgungsspannung Pin Bezeichnung Funktion 1 CO Fremdspannungsarme Erde Funktionserde FE 2 ov Versorgungsspannung 0 V GND 3 24