1. Command Class Basic Basic Set Value 0x63 or OxFF control the shutter to the top OxFF Command Class Basic Basic Set Value 0x00 0 control the shutter to the bottom 0x00 Command Class Basic Basic Set Value 0x01 0x62 control the shutter to the position between bottom and top 2 Binary Switch Command Class 2 1 BINARY_SWITCH_GET When PANO8 receive Binary Switch Get Command it will send Binary Switch Report Command to report the position of the shutter When the report value is 0x00 that mean the Shutter is bottom down if the report value is OxFF that mean the Shutter is at the top But if report value is OxFE means the position is unknown Binary Switch Get Command Command Class Binary Switch Binary Switch Get Binary Switch Report Command Command Class Binary Switch Binary Switch Report Value 0x00 BOTTOM Command Class Binary Switch Binary Switch Report Value OxFE UNKNOWN Command Class Binary Switch Binary Switch Report Value OxFF TOP 2 2 BINARY_SWITCH_SET PANO8 can only accept Binary Switch Set Command which value is either 0x00 Bottom or Top OxFF gt other value is not acceptable Command Class Binary Switch Binary Switch Set Value OxFF 255 control the shutter to the top OxFF But if the shutter is on the way down this command will stop the shutter Command Class Binary Switch Binary Switch Set Value 0x00 0 control the shutter
2. IDs are excluded 2 second on 2 second off Have Z Wave Controller entered One press one flash association mode Or Pressing Include button three times within 1 5 seconds will enter association mode 2 There are 1 group Group 1 for the PANO8 Association X Including a node ID allocated by Z Wave Controller means inclusion Excluding a node ID allocated by Z Wave Controller means exclusion X Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the PANO8 is in view from the LED for identification State Type LED Indication Motor No matter up or down close or open Led will flash every second activate while Motor activate When S1 or S2 close to L the LED will flash even when the motor stop by itself this is to let user Know the S1 or S2 still close and not been release yet No node ID Under normal operation when the PANO8 has not been allocated a node ID the LED flashes on and off alternately at 2 second intervals By pressing S1 S2 or Include button it will stop flashing temporarily However after disconnect and reconnect the power of PANO8 the LED will flash on and off alternately at 2 second intervals When overload state occurs the PANO8 is disabled and LED flashes on and off alternately at 0 5 second intervals PANO8 will send alarm_type 8 alarm _Level OxFF to Group1 Overload state can be cleared by disconnect and reconn
3. mmm ce X E Warning 1 Plug out to disconnect from power supply Do not plug in line 2 Do not exceed the max rating Disposal mi This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Company of License Holder Philio Technology Corporation Address of License Holder 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmfu
4. 2 Bytes of V Meter Value 1 Ox09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 6 2 4 AC load current When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report gt scale bit 2 Rate Type Meter Type gt Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Rate Type 0x01 Meter Type 0x01 Precision 2 scale 0x05 1 Size 2 Bytes Meter Value Meter Value 1 High Byte l Meter Value 2 Low Byte l Example scale 0x05 I Precision 2 Size 2 2 Bytes of Meter Value 1 0x01 l Meter Value 2 0x21 l AC load current Meter Value 1 256 Meter Value 2 2 89 A 6 2 5 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF PANO8 receive some control moving command from Z Wave RF Ex BASIC_SET gt BINARY_SWITCH_SET gt MULTILEVEL_SWITCH_SET gt Meter Report Command MULTILEVEL_SWITCH_START_LEVEL_CHANGE or Command Class Meter gt Meter Report gt scale bit 2 Rate Type Meter MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE PANO8 won t do any movement Type gt Precision Scale bit 1 0 Size Meter Value 1 change but re
5. Switch Start Level Change Up Down 0x03 Don t move the shutter or stop the moving shutter 5 1 Scene Actuator Configuration Set Command Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 0 Level 0 99 or 255 ATT 1 Ignore Start Level Start Level Dimming Duration Inc Dec Step size The current setting of PANO8 will not be override can not be used Command Class Scene Actuator Configuration Scene Actuator Configuration Set Scene ID 1 255 Override bit 1 Level 0 99 or 255 2 PANO8 can not control the speed of motor The Level value in this Command is associated to the Scene ID 3 It may have some distance error caused by motor start up time 5 2 Scene Actuator Configuration Get Command Command Class Scene Actuator Configuration Scene Actuator Configuration Get Scene ID 1 255 Command Class Scene Actuator Configuration Scene Actuator Configuration Report Scene ID 1 255 Level 0 99 or 255 Dimming Duration 0 0xFE Report the Pre configured Scene ID of PANO8 6 Z wave s Groups introduction Association Command Class Version 1 There is only one group called Group1 gt there is only one node for Group1 which support MULTILEVEL_SWITCH_ REPORT METER_REPORT_ COMMAND_VS3 gt ALARM_REPORT 6 1 Report the shutter position Every time when user press S1 or S2 and let shutter to move PANO8 will report the position status to controller and at the mo
6. 10 percent level it will auto report the level to Group 1 node 8 Command Classes The Switch supports Command Classes including COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_ BASIC COMMAND_CLASS MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_METER_V3 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_SWITCH_MULTILEVEL_V3 COMMAND_CLASS_ALARM COMMAND_CLASS_SCENE_ACTIVATION COMMAND_CLASS_SCENE_ACTUATOR_CONF Troubleshooting Symptom Cause of Failure The PANO8 not working 1 The PANO8 is not 1 Check power connections and LED off connect to the Main 2 Don t open up the PANO8 and send power it for repair 2 The PANO8 break down The shutter move direction Wrong connection of NC Swap the NC NO connection is reverse and NO to the motor PANO8 LED light work fine 1 No association setting 1 Carry out association But can not control 2 Same frequency 2 Wait for a while to re try interference 3 Release S1 and S2 3 S1 or S2 are pressed in Two Push Button switch type PANO8 would not accept RF command Specification sled vendor koee Resistive load 1100W 600W S50W EU US TW max Minimum 30 m in door 100m outdoor line of sight Operating Temperature OT 40T OC 400 S O Frequency Range PANO8 1 868 42 EU PANO8 2 908 42 USA Canada PAN08 3 922 5 923 9 926 3MHz Taiwan JP MHz Specifications are subject to change and improvement without notice
7. KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 Meter Report Command Command Class Meter gt Meter Report gt scale bit 2 Rate Type Meter Type gt Precision Scale bit 1 0 Size Meter Value 1 gt Meter Value 2 Meter Value 3 Meter Value 4 Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x00 KWh Size 4 bytes Meter Value Meter Value 1 KWh MSB Meter Value 2 KWh Meter Value 3 KWh Meter Value 4 KWh LSB Example Scale 0x00 KWh Precision 2 Size 4 Bytes KW h Meter Value 1 Ox00 KWh Meter Value 2 0x01 KWh Meter Value 3 0x38 KWh Meter Value 4 OxA3 KWh Accumulated power consumption KW h Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KW h 6 2 3 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter gt Meter Report gt scale bit 2 Rate Type Meter Type gt Precision Scale bit 1 0 Size Meter Value 1 Meter Value 2 Rate Type 0x01 Meter Type 0x01 Precision 1 scale 0x04 V Size 2 Bytes Meter Value Meter Value 1 High Byte V Meter Value 2 Low Byte V Example scale 0x04 V Precision 1 Size 2
8. PANO8 1 2 3 Roller shutter controller INCLUDE_ BUTTON MOTOR Relay 1C type COM Relay 1A type Fig 1 Assembling The in wall Roller Shutter Controller is designed to switch rise lower roller shutter connected to its terminals using radio waves controllers and a push button directly connected to this Roller Controller This in wall Roller Shutter Controller is a transceiver which is a Z WaveTM enabled device and is fully compatible with any Z WaveTM enabled network Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter This in wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method so it can be remote controlled not only fully up or down but also can be adjusted to ex 30 or 50 And when manual controlled by push button the controller also can memorize the position and send the new shutter position to its controller ex I P Gateway Adding to Z Wave Network In the front casing there is an include button with LED indicator below which is used to carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 2 second intervals It implies that
9. can stop by itself when go to bottom end or top end To manually switch up and down of the shutter simply press the external switch S1 or S2 The detail is described in 7 5 PANO8 built in meter function and can read the Watt KWh V Voltage I Current PF Power Factor of the load by using Z Wave command class user can set a threshold watt to get the warning caused by abnormal operation PANO8 have overload protection function and can help to prevent short circuit caused by load Programming Basic Command Class The PANO8 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET When PANO8 receive Basic Get Command gt it will send Basic Report Command to report the position of the shutter When the report value is 0x00 that mean the shutter is at the Bottom if the report value is 0x63 or OxFF that mean the shutter is at the Top any other value between 0x01 0x62 imply Shutter at the position between top and bottom Basic Get Command Command Class Basic Basic Get Basic Report Command Command Class Basic Basic Report Value 0x00 BOTTOM Command Class Basic Basic Report Value 0x01 0x62 Between BOTTOM and TOP Command Class Basic Basic Report Value 0x63 0xFF TOP 1 2 BASIC_SET PANO8 can accept Basic Set Command which value is either 0x00 Bottom or Top 0x63 0xFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 OxFE is not acceptable
10. ect the PANO8 to the main power Overload Choosing a Suitable Location 1 Do not locate the PANO8 facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the PANO8 is 0 40 3 Do not locate the PANO8 where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of PANO8 will become a little bit hot of which phenomenon is normal Installation and operation put the in wall PANO8 into a wall box and connect the AC power wire L N to PANO8 connector L N Connect the wall switch to the PANO8 as Fig1 lt is important to carry out a shutter calibration process before you control the shutter to move Press inclusion button over 3 seconds and release before the 6th second the roller shutter controller will start the shutter calibration process The process is composed of three continue stages The shutter move to the TOP in first stage and move to the BOTTOM in second stage and move to the TOP again in third stage Then PANO8 will Know the total range of UP and DOWN During the shutter calibration process any emergencies happen you can press and release the include button to stop the process If user found the direction is reverse this may cause by the wrong connection of NC and NO to the motor please change NC and NO connection and execute calibration process again For safe issue please select the motor which
11. en receive Alarm Get command and the PANO8 not in overload status it will send Alarm_Report Alarm Type 0x08 Alarm Level 0x00 6 3 1 Alarm Report When in Two Push Button switch type S1 or S2 close to L and not been release and Threshold 2 of KWH for Load Caution External 1 switch 1 1000 1 10000 0 KWh 1 1 One Push button 2 Two Push button a 1 1 2 1 1 Report destination level in 5s 2 Report 10 percent level while running 7 1 Watt Meter Report Period If the setting is configured for 1hour set value 720 the PANO8 will report its instant power consumption every 1 hour to the node of correspond Group The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr Default value is 1 hour 7 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 the PANO8 will report its Accumulated Power Consumption KW h every 1 hour to the node of correspond Group The maximum interval to report its Accumulated Power Consumption KW h is 227 55 days 10min 32767 1440 227 55 days Default value 1 hour 7 3 Threshold of Watt for Load Caution This is a warning when the wattage of load over the preset threshold value If the setting value is 1100 when the load wattage over this value PANO8 will send Watt Meter Report command to the node of correspond Group Default value 1100W 7 4 Threshold of KWh for Load Caution This is a warning when the KWh of load over t
12. he preset threshold value If the setting value is 10000 when the Accumulated Power Consumption of Relay1 or Relay2 over this value PANO8 will send KWh Meter Report command to the node of correspond Group minimum value is 1KWh and default value is 10000 kWh 7 5 External switch type 7 5 1 One Push Button The default configuration setting is Push Button only S1 input will be valid The control moving commands can be accepted in this switch type while the shutter is moving In this switch type the inclusion exclusion reset association function can also be fulfilled by pressing S1 just like the operation of include button When 1 is short pressed the shutter will move up toward TOP OxFF While in this moving S1 is short pressed again the shutter will stop moving A third short pressing of S1 will move the shutter down toward BOT TOM 0x00 While in this moving S1 is short pressed again the shutter will stop moving And so on Inverting direction and stopping 7 5 2 Two Push Button lf this setting is configured as Two Push Button S1 and S2 input will be valid but will not accept pressing Stand S2 at the same time In this switch type the inclusion exclusion reset association function can also be fulfilled by pressing S1 or S2 just like the operation of include button When S1 is pressed and hold more than 1 5 seconds the shutter will move up toward TOP OxFF and the shutter will stop moving when S1 is released W
13. hen S2 is pressed and hold more than 1 5 seconds the shutter will move down toward BOTTOM 0x00 and the shutter will stop moving when S2 is released When S1 is short pressed the shutter will move up toward TOP OxFF While in this moving short pressed S1 again the shutter just keep moving up toward TOP OxFF The easy way to stop this moving is short pressing S2 When S2 is short pressed the shutter will move down toward BOTTON 0x00 While in this moving short pressed S2 again the shutter just keep moving down toward BOTTON 0x00 The easy way to stop this moving is short pressing S1 When in Two Push Button switch type S1 or S2 are pressed and not released and PANO8 receive any control moving command from Z Wave RF Ex BASIC_SET gt BINARY_SWITCH_SET gt MULTILEVEL_SWITCH_SET MULTILEVEL_SWITCH_START_LEVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_CHANGE PANO8 won t do any movement change but report alarm to Group1 Alarm_Type 1 Alarm_level 0xFF this indicate that the S1 or S2 not been release ATT For avoid misunderstanding that RF command dose not work it is recommended to check the status of S1 and S2 7 6 Level Report mode Mode 1 In 5 seconds period after controlled by a moving command it will report the destination level when received request command Out of the 5 seconds period it will report the actual level of the shutter when received request command Mode 2 Whenever the shutter move pass a
14. it has not been assigned a node ID and cannot work with Z Wave enabled devices Auto Inclusion The function of auto inclusion will be executed as long as the PANO8 does not have Node ID and just connect the PANO8 to main power Note Auto inclusion timeout is 4 minute during which the node information of explorer frame will be emitted once every 5 seconds Unlike inclusion function as shown in the table below the execution of auto inclusion is free from pressing the Include button on the PANO8 The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM Certificated Primary Controller to access the Setup function and to include exclude associate devices Function Description LED Indication No node ID The Z Wave Controller does not allocate 2 second on 2 second off a node ID to the PANOB8 Inclusion 1 Have Z Wave Controller entered One press one flash inclusion mode 2 Pressing Include button three times within 1 5 seconds will enter inclusion mode Have Z Wave Controller entered One press one flash exclusion mode Exclusion Pressing Include button three times within 1 5 seconds will enter exclusion mode Node ID has been excluded 2 second on 2 second off 1 Pressing Include button three times One press one flash within 1 5 seconds will enter inclusion mode 2 Within 1 second press Include button again for 5 seconds until LED is off
15. l interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following l1 measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter
16. nd TOP Command Class Multilevel Switch Multilevel Switch Report 4 If user found the error become significant you may using S1 or S2 move Value 0x63 0xFF TOP shutter to the end or remote move shutter to 0 and 100 and that will automatically calibrate this error 3 3 MULTILEVEL SWITCH START LEVEL CHANGE This is the command which user can move the shutter up to the top or down to the bottom 3 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE Command Class Multilevel Switch Multilevel Switch Start Level Change When receive Multilevel Switch Stop Level change Command PANO8 will stop the Up Down Value motor 3 3 1 Up Down Bit If Up Down Bit 0x00 Shutter move up 4 SCENE ACTIVATION COMMAND CLASS If Up Down Bit 0x01 Shutter move down 4 1 Scene Activation Set Command If Up Down Bit 0x03 no move When PANO8 receive Scene Activation Set commana it will read the level of the pre configured Scene ID from EEPROM And it will be controlled as a Multilevel Command Class Multilevel Switch Multilevel Switch Start Level Change Switch Set command that described in 3 1 The Dimming Duration of the command Up Down 0x00 control the shutter to the top OxFF will be ignored because PANO8 can not control the speed of motor Command Class Multilevel Switch Multilevel Switch Start Level Change Up Down 0x01 control the shutter to the bottom 0x00 5 SCENE ACTUATOR CONFIGURATION COMMAND CLASS Command Class Multilevel Switch Multilevel
17. port alarm to Group1 this indicate that the S1 or S2 not been released Rate Type 0x01 Meter Type 0x01 When PANO8 detect a overload power it will report alarm to Group1 Precision 2 Command _Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level OxFF Scale 0x06 PF Overload Size 1 Bytes Meter Value 1 Command_Class_ Alarm Alarm _Report Alarm Type 0x08 Alarm Level 0x00 Normal Example Scale 0x06 PF Precision 2 When in Two Push Button switch type S1 or S2 are closed and not released to open Size 1 1 Byte of PF and PANO8 receive any control moving command from Z Wave FF it will report Meter Value 1 Ox63 PF alarm to Group1 Load power factor PF Meter Value 1 0 99 Command_Class_Alarm Alarm_Report Alarm Type 0x01 Alarm Level OxFF S1 or S2 close to L Command_Class_ Alarm Alarm_Report Alarm Type 0x01 Alarm Level 0x00 S1 and S2 released from L 6 2 6 reset Accumulated Power Consumption KWh This command is to reset the Accumulated Power Consumption KWh to 0 Meter Reset Command Command Class Meter Meter Reset 7 Z Wave s Configuration Configuration Size Value Description Parameter Byte J 2 0x01 5s 720 5 720s 3600s 1 Ox7FFF hour 2 0x01 6 10min 1 hour Ox7FFF i Threshold 2 10 1100 of Watt for Load Caution 6 3 Alarm Report Command When PANO8 detect Overload it will send Alarm_Report to Group1 Alarm Type 0x08 Alarm Level OxFF Wh
18. to the bottom 0x00 But if the shutter is on the way up this command will stop the shutter 3 Multilevel Switch Command Class Version 3 3 1 MULTILEVEL SWITCH SET PANO8 can accept Multilevel Switch Set Command which value is either 0x00 Bottom or Top 0x63 or OxFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 0xFE is not acceptable Command Class Multilevel Switch Multilevel Switch Set Value 0x63 or OxFF 255 control the shutter to the top OxFF Command Class Multilevel Switch Multilevel Switch Set Value 0x00 0 control the shutter to the bottom 0x00 Command Class Multilevel Switch Multilevel Switch Set Value 0x01 0x62 control the shutter to the position between Bottom and Top 3 2 MULTILEVEL SWITCH GET When PANO8 receive Multilevel Switch Get Command it will send Multilevel Switch Report Command to report the position of the shutter When the report value is 0x00 that mean the shutter is at the Bottom if the report value is 0x63 or OxFF that mean the shutter is at the top any other value between 0x01 0x62 imply shutter at the position between top and bottom Switch Multilevel Get Command Command Class Multilevel Switch Multilevel Switch Get Multilevel Switch Report Command Command Class Multilevel Switch Multilevel Switch Report Value 0x00 BOTTOM Command Class Multilevel Switch Multilevel Switch Report Value 0x01 0x62 Between BOTTOM a
19. ving process when change over 10 PANO8 will send Multilevel Switch Report to Group 1 also Multilevel Switch Report Ex Report position at 30 Command Class Multilevel Switch gt Multilevel Switch Report gt Value 30 6 2 Meter Command Class The Switch will report its 1 instant Power Consumption Watt or 2 accumulated power consumption KWH or 3 AC load Voltage V or 4 AC load current I 5 load power factor PF to Z Wave Controller after receive the Meter Get Command from Z Wave Controller When the power consumption of load vary over 5 it will send Meter report to the nodes of Group as well 6 2 1 Instant Power Consumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Command Class Meter Meter Report gt scale bit 2 Rate Type Meter Type gt Precision Scale bit 1 0 Size Meter Value 1 gt Meter Value 2 Meter Value 3 Meter Value 4 Rate Type 0x01 Meter Type 0x01 Precision 1 scale 0x02 W Size 4 Bytes Meter Value Meter Value 1 W MSB Meter Value 2 W Meter Value 3 W Meter Value 4 W LSB Example Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 OxEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 6 2 2 Accumulated Power Consumption

Download Pdf Manuals

image

Related Search

Related Contents

Comercial Lozano  ・ 取扱説明書  細~ニ星 歩行中の子供の交通事故原因の約7割は 「飛び出し」  Scarica il libretto di istruzioni  Ladinginn。vati。))) 芝電球スタンド取扱説明書 保管用  PCリンクソフト LE  Betriebsanleitung 6020 - Flugschule  Cooler Master CM Storm Reaper  DANA 30 OX Locker This is your OX Locker installation  Sanyo CLT1554 CLT2054 User's Manual  