Home
# 20054 - Aquatica
Contents
1. Lubricant for O rings WARNING The Aqua View has no user serviceable internal part dismantling or tampering your Aqua View Finder will void its warranty and may cause irreparable damages and or flooding of the unit and its housing AQUATICA 3025 De Baene St Montreal Quebec Canada H4S 1K8 Tel 514 737 9481 info aquatica ca Fax 514 737 7685 YUATICA ee Digital Thank you for acquiring the Aqua View Finder from Aquatica Part 20054 the view finder op tics are made from high quality coated glass elements and as such should be treated with the same respect as your camera lenses or any precision optical tool the casing is ma chined from aircraft quality aluminium and anod ized for protection again salt water corrosion Your Aqua View Finder is supplied with the fol lowing One Soft carrying pouch a protective cap an allen key and a spanner wrench for eyesight adjustments Following are simple steps for the installation of the Aqua View First The regular eyepiece on your housing must be removed from the rear of the housing On the inside of the housing rear portion locate the eye piece collar notice the retain ing rubber O ring protruding from it remove this O ring with either an O ring tool or a dull pointed object making sure not to cut it Once the O ring is removed push the eyepiece out by pressing on the metal collar with both thumbs from the inside Remove the retaini
2. 1 Allignement pin slot 2 Retaining O ring removal slot 3 Adjustment holes for spanner wrench 4 Optical barrel locking set screw 5 Retaining O ring 6 Sealing O rings x2 Warning When traveling always remove the eyepiece from the housing and never lift or carry the housing using the Aqua View Finder as a handle It is your responsibility to advice people handling your equipment accordingly Treat your eyepiece with care and store in a padded container or lens bag Eye piece adjustment Dioptric correction is possible in order to adjust to one s eyesight Your Aqua View Finder is supplied with a small hexagonal wrench and a round adjustment spanner First the eyesight adjustment of your camera should be properly adjusted to your eye to do this refer to the camera user manual If adjustment are still required then start by selecting an object located far away any structure with fine details etc Loosen the set screw on the Aqua View barrel A using the hexagonal wrench supplied rotate the optic barrel B in small increment using the adjustment tool supplied C When properly adjusted objects located at infinity should appear sharp and defined once the ad justment completed mount you Aqua View Finder on your housing the information visible in your view finder shutter speed aperture etc should be clear and sharp Optional accessories Product 19216 Hard protective case see photo Product 19213 Aquatica
3. N 30D YES CANON 20D NO CANON T2i 550D YES CANON DIGITAL REBEL 300D NO HOUSING FOR Panasonic DMC GH4 YES Olympus OM D E M1 NO HOUSINGS FOR Nikon D4 D4s YES Nikon D3 D3S amp D3X YES Nikon D2x D2xs amp D2H YES Nikon D810 YES Nikon D800 YES Nikon D700 YES Nikon D600 amp D610 YES Nikon D300s YES Nikon D300 YES Nikon D200 amp Fuji S2 Pro YES Nikon D7100 amp 7200 YES Nikon D7000 YES Nikon D40 D40x amp D60 YES Nikon D90 YES Nikon D80 YES Nikon D70 amp D70s YES Nikon D100 NO AQUATICA Digifsl A A Woo 45 View All current Aquatica housings for DSLR manufactured after 2004 are compatible with the Aqua View Finders Some pre 2004 housing were compatible in order for a housing to be compatible it should have a removable eye piece retained with an O ring see image below NON REMOVABLE EYE PIECE REMOVABLE EYE PIECE Revised September 15 2015
4. ng O ring from the collar of your Aqua View Finder flip the housing back cover so that you are facing the external part of it inspect and apply a light coat of lubricant on the wall of the sealing surface of the housing making sure it is clear of debris inspect carefully the two remaining O ring from the Aqua View Finder to insure they are clean and lubricate them remember that a light coat is all that is needed the O ring does the sealing not the lubricant It is the user responsibility to make sure that all O rings are cleaned and properly installed Insert the Aqua View Finder by slightly rotating left and right Align the cut out on the Aqua View Finder external collar so the small stainless steel alignment pin come to rest in that cut out Finally turn the housing back cover over and reinstall the retaining O ring on the Aqua View finder internal collar As always is the case when installing components such as ports ex tension or viewfinder a pressure test should be made using a Surveyor vacuum monitoring system if your housing is so equipped or an immersion test of the housing without the camera should be performed to confirm that the view finder was installed properly AQUA VIEW COMPATIBILITY HOUSINGS FOR CANON 1Dc amp 1Dx YES CANON 1DS Mk Ill amp 1D Mk IV_YES CANON 5DS amp 5Dsr YES CANON 5D Mk III YES CANON 5D Mk II YES CANON 5D YES CANON 7D Mk II YES CANON 7D YES CANON 70D YES CANON 40D amp 50D YES CANO
Download Pdf Manuals
Related Search
nick fuentes borderlands 4 shift codes charlie kirk shooting tyler robinson wolfgang van halen colorado school shooting stock market today erika kirk
Related Contents
Manual - Deitz Company Inc iStarUSA DAGE316U40-4MS disk array Whirlpool EV187NYRQ02 User's Manual Copyright © All rights reserved.
Failed to retrieve file