JA 163A RB

image

Contents

1. JABLOTRON ALARMS a s A W OTRON o JABL A P Pod Skalkou 4567 33 46601 Jablonec n Nisou Czech Republic www jablotron com CREATING ALARMS JA 163A RB Wireless outdoor battery powered siren The JA 163A RB is a component of the JABLOTRON 100 system It is used for system alarm indication outside a building It can also be used for supplementary acoustic signalling PG activation setting unsetting chirps etc The siren is powered by just one lithium battery with no other external power The JA 163A RB consists of the JA 163A BASE with PCB and a BAT 100A lithium battery and always has to be completed with a desired cover from the JA 1X1A C xx series see following table The siren occupies one position in the system The product should be installed by a trained technician with a valid certificate issued by an authorized distributor For combinations of colour and cover material see the Colour and cover Strobe colour material Grey plastic Stainless steel sheet following table White plastic Grey plastic Stainless steel sheet blue White plastic Installation The whole enrollment procedure has to be done in service mode of the control panel There must be a JA 11xR radio module installed in the control panel Figure 1 1 hole for installing 2 piezo sounders 3 BAT 100 lithium battery with reusable battery strap up to 2 batteries c
2. an be used 4 PCB 5 spirit level 6 hole for installation with tamper detection 7 front cover screw 8 string with clip connecting the front cover for easy installation A 1 Attach the siren onto a suitable place using 2 screws through the holes 1 and 6 The spirit level can be used for easy installation 5 2 Connect the BAT 100A lithium battery 3 to the connector 11 The siren should be installed on a vertical wall with the flashing light facing downwards Avoid installing the siren near the gutters and on other places where there is a danger of ice accumulation JA 163A Wireless outdoor battery powered siren Figure 2 9 production code 10 LEARN enrollment button 11 battery connector 12 yellow fault indicator 13 mini USB connector 14 piezo siren connection attention high voltage 15 external antenna connector 16 high intensity red LED flashers 3 Proceed according to the control panel installation manual Basic procedure a When the battery is connected the yellow LED 12 indicates by a permanent light that the siren has not been enrolled into the system yet b Go to the F Link software select the required position in the Devices tab and launch the enrollment mode by clicking on the Enroll option c Press the button marked LEARN 10 the siren is thus enrolled and the yellow LED indicator goes off 4 Install the siren cover and attach it
3. ction YES NO it sets if a siren should optically indicate setting and unsetting of a section s It blinks once when set and it blinks twice when unset and when unset after an alarm then three blinks This option is available only if the periodical communication is set to 1 s LED indication red blue sirens are equipped with dichromatic LED indicators According to the colour of the provided front cover it is necessary to set the same colour of LED indication Siren flashing options During alarms 1 3 5 30 60 min of flashes after an alarm This option sets the length of siren flashing for only the alarm time or extended for by a pre set interval Extended flashing can be terminated by new system setting or cancellation of alarm indication in the system with a keypad Periodical communication 1s 8s This parameter sets the maximum delay in siren reaction to an alarm When the option 8 s has been selected then it is not possible to enable some options such as set unset indication Notes PG output activation sometimes might not be indicated when periodical communication is set to 8s and a PG output is switched ON for a shorter time than 8 s When periodical communication is set to 1s it can reduce the typical battery lifetime by half PG output indication The siren can indicate the activity of selected PG outputs with its chirps Chirp 1 slow chirping 1 per second for the whole period when the PG i
4. election of the sections for which other sounds mentioned below will be produced Default setting is no section selected A Higher volume YES NO affects only entrance exit delay indication and sounds indicating PG output triggering It doesn t have any influence on the sound of an alarm Enabling of any here mentioned options causes a reduced battery life time depending on the frequency of its use That s why we recommend fitting the BAT 100A second battery Beeps during section control YES NO if enabled the siren chirps once after setting twice after unsetting and three times when unsetting after an alarm It only does so when the option Periodical communication is set to 1 s Entrance delay beeping YES NO if enabled it indicates the entrance delay time intermittent beeping MNM51100 JA 163A RB Wireless outdoor battery powered siren Exit delay beeping with a partially set system YES NO if enabled it indicates the exit delay for the whole time when the system has been partially set intermittent beeping This option is available when Exit delay beeping is enabled Exit delay beeping YES NO if enabled it indicates the exit delay time when the system is fully set intermittent beeping Optical indication Flashes every 60 seconds YES NO It sets to one siren flash per minute It can be used as a warning that the building is protected by an alarm system When controlled by a se
5. s active Chirp 2 rapid chirping 2 per second for the whole period when the PG is active Chirp 3 1 chirp when the PG is activated 2 chirps when the PG is deactivated Chirp 4 along 20 sec chirp when the PG is activated Sound priorities The siren sound has the highest priority the control chirps have a lower priority and the PG output activity indication has the lowest priority PG1 has a higher priority than PG2 etc A chirp with a higher priority always terminates chirping with a lower priority External antenna use To improve the communication quality between the control panel and the outdoor siren you can connect an external antenna AN 868 Plug the antenna into the connector 15 on the PCB Battery replacement The product checks the battery status automatically When a battery fault is triggered the system informs its user or service technician The siren remains fully functional but we strictly recommend to replace the battery within 2 weeks Never try to charge the battery Use the BAT 100A type only The battery can be changed in control panel service mode by a service technician When replacing is finished test the siren s functioning Take the used battery to an official collection point don t throw it into the trash JA 163A Wireless outdoor battery powered siren 2 1 Technical specifications The JA 163A RB parts lithium battery front cover and base are supplied individually The reason i
6. s the free selection of a wide range of a front covers and the transportation of lithium batteries Power Lithium battery 3 6 V 13 Ah type BAT 100A up to 2 batteries can be used Please note Batteries are not included approx 5 years for dafaultsettings 868 1 MHz JABLOTRON protocol approx 300 m open area internal external can be used type AN 868 110 dB m new battery 200 x 300 x 70 mm grade 2 EN 50131 1 EN 50131 4 IV general outdoor 25 to 60 C IP44 ETSI EN 300220 EN 50130 4 EN 55022 EN 60950 1 ERC REC 70 03 JABLOTRON ALARMS a s hereby declares that the JA 163A is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC and 2011 65 EU The original of the conformity assessment can be found at www jablotron com Technical Support section Typical battery lifetime Communication band Communication range Antenna Piezo electric siren Dimensions cover included Classification According to Environmental class Security grade Also complies with Can be operated to CE Note Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use For more detailed information visit www jablotron com MNM51100
7. using the screw 7 5 Set siren properties according to the Internal settings of the siren chapter Notes The siren can also be enrolled into the system by entering its production code 9 in the F Link software You can find the production code on the sticker glued on the PCB All numbers under the bar code shall be entered 1400 00 0000 0001 The siren can be powered by up to two BAT 100A batteries and we recommend this when longer siren operation time is required There is a place prepared for second battery use see Figure 1 Connect the battery to the other connector 11 The battery connection order doesn t matter Internal settings of the siren The siren properties can be set in the Devices window of the F Link software When at the siren position use the Internal settings option to open a dialog window internal setting is separated into 2 tabs Settings and PG indication default settings are marked Settings tab Sections to set for which sections the siren should indicate an alarm as well as setting the chirps The default setting is indication for all sections disabled Reaction defines whether the siren should indicate EW external warning or IW internal warning Alarm indication can also be disabled completely other functions remain enabled Siren sound intermittent continuous Option intermittent saves energy Maximum siren time 1 2 3 4 5 minutes Acoustic signalling in a section s