1. In case of cardholders in putting card private information ID weight height is displayed in reverse monitor In case for you to want to modify weight or height you push weight button or height button and then modify it When putting card it s impossible for you to modify ID 2 Measurement When you finish input data press START button and then begin to measure When measurement is begun animation notifying measuring is displayed When putting reverse monitor you must push START button on reverse monitor and then height weight body mass index fatness is displayed in the screen of thermal paper and reverse monitor Since weight height you put is reflected on the result body mass index B M l fatness you must put accurately pon 000012345 When measurement is complete body mass index B M I fatness is displayed based on ID weight and height in LCD 24 kg n 109 4 Standard for judging result e Body Mass Index B M I this is calculated by dividing body weight by the square of height in meter section 18 5kg m 18 5 lt 25 0kg m 25 0 lt 30 0kg m 30kg m and over Fatness value showing your current fatness of weight for standard weight current weight standard weight standard weight X100 100 standard weight height m X 22 section 8096 9096 90 110 11096 12094 gt 120 34
2. 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the EASY X 800 is used exceeds the applicable RF compliance level above the EASY X 800 should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the EASY X 800 Over the frequency range 150 kHz to 80 MHz field strengths should be less than V m 4 Recommended separation distances between portable and mobile RF communications equipment and the EASY X 800 The EASY X 800 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the EASY X 800 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the EASY X 800 as recommended below according to the maximum output power of the communications equipment Rat
3. Shipping and insurance costs for return of defective unit must be prepaid by the users 5 SAFETY SYMBOLS AND INFORMATION The International Electrotechnical Commission IEC has established a set of symbols for medical electrical equipment which classifies a connection or warning of any potential hazard The classifications and symbols are shown below Save these instructions for your safety Degree of protection against electric shock TYPE BF Please observe operating instructions General warning sign General prohibition sign General mandatory action sign Caution Waste Electrical and Electronic Equipment WEEE The device could be sent back to the manufacturer for recycling or proper disposal after their useful lives Alternatively the device shall be disposed in accordance with national laws after their useful lives OFF only for a part of equipment ON only for a part of equipment This symbol is used inside system Identifies the point where the safety ground of the system is fastened to the chassis Do not open This is for factory only Alternating current Date of manufacture Manufacturer Non ionizing radiation Authorized representative in the European community 4 o Keep dry 52 0 6 Guidance for Electromagnetic compatibility EMC Details about the electromagnetic compatibility EMC of the EASY X 800 are given below Before using the EASY
4. specifications for operation and programs attached to the card writing device at purchase 16 2 PRINTER D PRINT button Use it when you print out the data If you set ON at the rear PRINT ON OFF switch the data is printed automatically even when you do not press PRINT button Normally when you press this button one previous data will be printed If you turn it off all memorized data would be deleted When you set the date and time the number goes up with this button pressed 2 FEED button Use this button for setting the paper When you set the date and time the number goes down with this button pressed 3 SET button Set the date and time The functions are as follows when pressing this before or after measurement It does not work during measurement Sequence is HOUR MIN gt MON DAY YEAR f you do not press PRINT or FEED button within 5seconds setting of the date and time finished See the page 15 for detailed method 17 3 REAR PART CD POWER It is used to turn the power on and off 2 POWER INPUT It is used to connect with the adapter 3 CAL This is only for inspection Never open it 4 EARTH POTENTIAL EQUALIZATION TERMINAL Please make sure for safety 6 COMMUNICATION PORTS RS 232C Connect between the main body and a computer or other equipment with cable RS 232C to transfer the data collected or measured Or connect between the main bod
5. 19 4 ACCESSORIES Adapter Power cable Manual USER S GUIDE FOR MEASUREMENT l Please take off any thick clothes Relax before the measurement Put your arm through deep and make your 2 2 elbow fixed the wall inside Press START button Please try not to move or speak dut measurement The cuff sonata e sloose whenthe measurement is completed When you feel pain or want to stop the measurement Please press STOP EMERGENCY button immediately If you have any bask probem or suspect you do please consult with a doctor Ple that findings from the measurement of this device llowedto be used as the of any deliberate diagn cider diei rte prescription m Sj the it be relaxed and have a good rest for a arnin 9 in a bad position such as standin or r sitting with your Makes its way from hospital to home www jawon com Tel 82 2 587 4056 RFID Card Maanetic Card MAKES ITS WAY FROM HOSPITAL TO HOME MAKES ITS WAY FROM HOSPITAL TO HOME HEALTH S CARE 7 JAWON MEDICAL Thermal paper Printer Human sensor AUTOMATIC CUTTER 58mm Thermal printer Reverse monitor support cable INSTALLATION 1 CONNECTION ADAPTER Just connect the power cable to the adapter on the rear and turn the POWER ON OFF switch on the lower part of the rear See the picture In order to avoid the risk of electrical shock connect this device only
6. 4 Kgim The result is pre pr pare Refer to the results and consult to physician MM u PULSE WAVE PATTERN ie fey 1 175 B59mmHa perm PULSE L mmHg bpm 30 04 08 112 2 66 40 04 68 111 5s o 08 38 MAINTENANCE This unit is for 230V If you want 110V please Remind the permitted current 60 VA contact to a service center To prevent electric shock please make sure the earth When grounded do not mount it close to the gas pipe water pipe lightening rod and connection of telephone XY Keep the unit dry and do not wet it Avoid direct sunshine humidity dust and Never immerse the main unit in the water extreme changes in temperature It could cause damage the electronic parts inside acr 3 Ba 39 Do not put heavy things on the unit Wipe the unit with a damp cloth Do not use benzine alcohol or liquid similar to solvents and wet cloth Do not use the unit under the condition of shock or vibration When you re use after a long time please check the unit carefully When some problems are found please call our service center 40 ERROR amp REPAIR ERROR PRESSURE pressure is high with When the message is jammed air hose repeated call for maintenance service ERROR CUFF pressure is low as air leaks When the message is repeated call for maintenance service ERROR
7. In case of stopping setting the values return to previous ones which you have done before The calendar and time functions work without plugging power cord in Calendar program is inputted for 100 years and it would be adjusted automatically even at a leap year 24 S MEASUREMENT 1 CAUTIONS FOR MEASUREMENT Take off heavy sweater or shirts Before measurement take it easy and have a rest for a while Do not measure in bad positions such as standing half seat or sitting with your legs crossed When you fold your sleeves up please make Put your arm deeply in order to fit to the arm sure not to press your arm rest If you strain to your arm there will be some differences Please relax your arm and have a seat correctly If it is not easy to check your pulse with the stethoscope the measurement cannot go on 25 2 MEASUREMENT o Check the voltage and turn the power on 2 With the switch on a music sound flows as the LED screen is activated But the SOUND ON OFF switch in the rear of the unit should be setas 3 For the card users proceed with checking after entering the card into the card reader When the card is inserted a voice message comes out to Press the start button For ID card using the CARD ON OFF switch in the rear of the unit should be set as If the card is damaged or expired the voice message comes out as not use ID card In this
8. MEASURE subject moves or speaks Don t move or speak while in testing When the message is repeated call for maintenance service 4 AFTER SERVICE 1 AFTER SERVICE qp If there is any problem with the unit please follow the steps below Contact our company s Overseas Service Department immediately After gathering the model name Serial Number date of purchase and description of the problem contact our company with information shown below x Try to solve the problem over the phone with the personnel of local service department If the problem cannot be solved over the phone just return to service department directly x Our company or local distributor will make available on request circuit diagrams component part list descriptions calibration or other information which will assist your appropriately qualified technical personnel to repair those parts of unit which are designated by our company as repairable How to contact our company Write us at JAWON MEDICAL CO LTD 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do Korea TEL 82 53 856 0993 FAX 82 53 856 0995 You can also contact the following representative or your local distributor 2 PACKING AND TRANSPORT Our company follows his packing ways to protect any impact during transporting etc So please do not transport or move the unit without our company s packing condition as your wishes The normal storage environment 20 C
9. Where the unit is exposed to explosive gas Where the unit is exposed to excessive shocks or vibrations Where the angle of inclination of mounting surface exceeds 10 degrees Where the unit is exposed to direct sunlight This equipment has been tested and found to comply with the limits for medical devices to IEC 60601 1 2 2007 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to other devices which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving device Increase the separation between the equipment Connect the equipment into an outlet on a circuit different from that to which the other device s are connected Consult the manufacturer or field service technician for help 9 Do not to touch signal input signal output or other connectors and the patient simultaneously N10 a statement that MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs t
10. the cuff When the PRINT ON OFF switch on the rear is set as OFF the result will not be printed even if the measurement is completed For the card users six previous results stored in the card can be recalled to compare with the current ones newly checked Seven results altogether could be printed out This device is only for adult 28 3 DATA ON MEASUREMENT BY PRINTER V Results on Printing Paper SYSTOLIC 126 mmHg DIASTOLIC 070 mmHg MEANPRESS 088 mmHg PULSEPRESS 056 mmHg PULSE 082 bpm to physician s The result is LM Refer to the results and consult FUSE Y WAVE PATTERN Classification of the blood pressure National High Blood Pressure Education Program National Heart Lung and Blood institute NIH JNC7 2003 DiastolicimmHgl 100 90 Prehypertension po EE Nema 120 140 160 Systolic mmHg 29 When pressure is high with the jammed air hose message appears on the printer as ERROR PRESSURE When the message is repeated call for maintenance service When pressure is low as air leaks message appears on the printer as ERROR CUFF When the message is repeated call for maintenance service When the subject moves or speaks while in testing message appears on the printer as ERROR MEASURE Try to retest after a while If the message is repeated call for maintenance service 30 one 1 Reverse monitor 1 Attachment of the reverse
11. 15 2 PRINTER 17 ME 18 LAC GES ORE uictum bistro 20 SNOLUNOI OO 20 INSTALLATION seeeenn nnnm nnm nnnm nnnm nnns 21 1 21 2 LOADING THE PRINT PAPER ee ee eee 21 CONNECTING PORTS 232 22 4 SETTING TIME AND 23 MEASUREMENT sse nnnm nennen nns 25 1 CAUTIONS FOR MEASUREMENT cccsseccceeeeceseeccaeeesceeseeseeeeneeees 25 2 MEASUREMEN w t 26 DATA ON MEASUREMENT BY 29 o OPTION Rn nnn 31 dual nire 39 amp mene 41 AFTER SERVICE 42 SERVICE 42 2 PACKING AND 42 SPECIFICATION 43 44 A INTRODUCTION We highly appreciate that you chose our company s product You are kindly requested to be familiar with these directions before using this product and always keep it together with the product In case you are not sure about any directions or problems arising while using the product please contact
12. 2 MAGNETIC CARD Machine manager can issue cards through supportive card issuer in machine s delivery you can issue it yourself When machine manager issues cards please refer to card issuer or program manual 1 Setting ke In card s using you should set CARD ON OFF in rear part by ON CARD ON OFF switch of the rear part of the machine must be set by in order to use card In using card if the validation date has been expired or the damaged card is inserted the voice message You cannot use ID card appears In this case you purchase a new card and insert so you can measure 2 Measurement D Card recognition You hold your card and then swipe it up and down from card reader If card is recognized normally it sounds Ttiriring and it becomes in the state of being ready for measurement In connected reverse monitor ID stored in a card is displayed in the reverse monitor Then you can put weight and height in the reverse monitor 2 Measurement If you finish recognizing card voice and message Please press the start button comes out Push the start button and then begin to measure When measurement started cuff pressure begins 3 Result When the measurement is completed systolic blood pressure diastolic blood pressure pulse is displayed on the LED 35 4 Print out the result of the measurement V using only magnetic card Y Magn
13. 60 C of temperature Humidity is less than 95 non condensing 42 AE SPECIFICATION EASY X 800 R EASY X 800 L Measuring method Oscillometric Display mode High Brightness LED 197X145mm display Systolic Diastolic Mean blood pressure Pulse pressure Pulse Blood pressure assessment Pulse wave pattern Result Contents mE Reverse Monitor Option Systolic Diastolic blood pressure Pulse ID No B M I and Fatness Pressure 30 300mmHg Pulse 30 200beats minute Pressure x3mmHg or 3 Pulse 3 Output DC 12V 5A ADAPTER Temperature 10 40 Humidity 30 75 463 W x 461 D x 276 H mm 43 A WARRANTY WARRANTY Automatic Blood Pressure Monitor Warranty period 1year main unit only Date of purchase Month Day Year Name TEL Customer Name TEL Dealer When you receive this warranty make sure that the name of the dealer and the month day and year of purchase are all completed This warranty will not be reissued please keep it in a safe place 44 Periodic Check List Management No Visual Check Visual Check o d Mainframe 1 Enclosure No scratch crack Pass Fail CT 2 Labels and panels No peeling and dust Nodemae Passa _ MechanicalCheck 3 1 Accessories 2 Recorder Smooth operation with no Pass Fail abnormal sound 3 Cuffs Smooth operation Pass Fail Power cord Smooth operation and Pass Fai
14. CAL HEAD OFFICE 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do Korea TEL 82 53 856 0993 FAX 82 53 856 0995 EUROPEAN REPRESENTATIVE VITAKO Sp z o o UL MALEJ SYRENKI 2 71 790 SZCZECIN POLAND TEL 91 8522900 901 FAX 91 8522910 JW EX800E 20150930 Rev 4 0
15. OWNER S MANUAL EASY X 800 R L e Safety design with soft curved line Simple one touch operation Instructions by voice messages High speed printer with automatic paper cut Built in emergency safety button Compare and analysis the result with Card re Convenience to see the result on the reverse iJAWON j JAWON MEDICA Our company name will be changed to JANEX MEDICAL The device bears the CE label in accordance with the provisions of Medical Device Directive 93 A2 EEC THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93 42 EEC Jawon Medical Co Ltd 29 Gongdan 4 ro Jillyang eup Gyeongsan si Gyeongsangbuk do Korea TEL 82 53 856 0993 FAX 82 53 856 0995 VITAKO Sp z o o UL MALEJ SYRENKI 2 71 790 SZCZECIN POLAND TEL 91 8522900 901 FAX 91 8522910 A TABLE OF CONTENTS INTRODUCTION 4 1 INTENDED USPE seesssesssseeeenennnneennmnennm nnn nnns 4 c 4 3 CLASSIFICATION AND 5 4 SAPETY PRECAUTION ee ee 5 5 SAFETY SYMBOLS AND 8 6 Guidance for Electromagnetic compatibility EMC 10 e TERMS OF EACH PART AND 15 Te WE ROOT PAR m
16. X 800 be sure to read and understand the following information 1 Guidance and manufacturer s declaration electromagnetic emissions The EASY X 800 is intended for use in the electromagnetic environment specified below The customer or the user of the EASY X 800 should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance The EASY X 800 uses RF energy only for its internal RF emissions function Therefore its RF emissions are very low and CISPR 11 are not likely to cause any interference in nearby electronic equipment RF emissions Class B CISPR 11 Harmonic The EASY X 800 is suitable for use in all emissions Class A establishments including domestic establishments and IEC 61000 3 2 those directly connected to the public low voltage Voltage power supply network that supplies buildings used for fluctuations domestic purposes Compliance flicker emissions IEC 61000 3 3 2 Guidance and manufacturer s declaration electromagnetic immunity The EASY X 800 is intended for use in the electromagnetic environment specified below The customer or the user of the EASY X 800 should assure that it is used in such an environment IEC 60601 test Compliance Electromagnetic environment Immunity test level level guidance Floors should be wood concrete or Electrostatic discharge ESD IEC 61000 4 2 6kV Contact 6kV Contact ceramic tile If floors are co
17. ation the information is all removed and initialized When pushing a button while measuring stop measuring and therefore cuff is back to the original state 17 START button When pushing a button after putting ID weight and height automatically cuff is pressurized and it starts measuring Reverse monitor 2 Systolic blood pressure 3 Diastolic blood pressure 4 Pulse YS mmHg DIA mntg PULSE bpm STOP STOP button Height Number button D LCD screen pe EN 17 START button e button 5 ID button 8 PRINT button 6 WEIGHT button 7 HEIGHT button 32 4 Measurement CD Input data Information ID After pressing ID button in the initial screen put ID using 0 9 numeric button 000012345 go back to the initial screen unless you don t put for 40 seconds Weim OO 0 ID limitation you can put is 000000001 999999999 000 0cm s Information Weight After putting ID putting WEIGHT button you put body weight using 0 9 1 000012345 numeric button go back to the initial screen unless you don t put for 40 74 8k IK seconds 000 Body weight limitation you can put is 10 0 248 0kg Height After putting body weight putting HEIGHT button you put height using information 0 9 numeric button go back to the initial screen unless you don t put for 40 i 000012345 seconds 74 Height limitation you can put is 10 0 238 0cm 176
18. case purchase new one and try again 4 put either the right arm or left arm into the cuff An optimal arm circumference for this equipment is 9 to 14 26 Place your arm on the arm supporter with the palm facing up through the cuff deeply Adjust the height of the chair so that the arm is leveled off with the heart When the arm is placed lower than the heart blood pressure will become higher than actual value and vice versa Press the START button and then the cuff is automatically inflated and the measurement is stated When the measurement is started the voice message iS announced Starting measurement don t move or speak please When you feel painful and want to stop the measurement press EMERGENCY BUTTON When the measurement completed the cuff is automatically deflated and it returns to normal condition Simultaneously the voice message is announced as Measurement completed pull your arm out please Thank you When the measurement is not satisfactory the voice message comes out as Cannot measure we will try again At this time let your arm stay into the cuff and start over again from the beginning 27 o Blood pressure and pulse rate are displayed on LED and then the results are printed out Also the results are informed by the voice message as Your blood pressure is systolic 000 diastolic 000 and pulse 000 Pull your arm out from
19. ed maximum Separation distance according to frequency of transmitter output power of transmitter 150 kHz to 80 MHz 80 MHz to 900 MHz 900 MHz to 2 5 GHz d 1 P d 1 P d 1 P 0 12 0 23 0 38 0 73 2 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer 1 At 80 MHz and 900 MHz the separation distance for the higher frequency range applies 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 14 A TERMS OF EACH PART AND FUNCTIONS 1 FRONT PART 1 START BUTTON Press START button after being ready to measure the cuff will be wrapped automatically and begins to pressurize 2 STOP BUTTON Press STOP button if you want to stop it during measurement Pressurizing will stop and the air will exhaust from the cuff 8 SYSTOLIC DISPLAY It indicates systolic blood pressure values 4 DIASTOLIC DISPLAY It indicates diastolic blood pressure values 5 PULSE DISPLAY It indicates pulse rate 6 TIMER It indicates time EMERGENCY STOP BUTTON When your arm is oppressed due to high pressurizing or irregular operation is done press this button th
20. egin to measure When measurement started cuff pressure begins 3 Result When the measurement is completed systolic blood pressure diastolic blood pressure pulse is shown in the LED 1 In using card Magnetic amp RFID card previous measured result is stored by six times it shows the total seven times measured result including current measure result When you push START button in the result screen the current measured result and six times accumulated data is displayed in LCD In Printing out the current measured result and the accumulated data confirming change of blood pressure are output In case of using card and reverse monitor option you put your weight and height after putting card Then both B M I and fatness are output Weight and height in reverse monitor are stored and in case of remeasuring it you don t need to repeat it The method of putting for the reverse monitor please refer to p 24 37 4 output the result of measurement in using only RFID card 4 26 mmHg 070 mmHg MEANPRESS 088 mmHg PULSEPRESS 056 mmHg PULSE 082 bpm The result is pre hypertension Refer to the results and consult to physici cian PULSE WAVE PATTERN A toe qoe 175 BU wa di PULSE RFID card in putting the rear monitor SYSTOLIC 4 26 mmHg DIASTOLIC mmHg MEANPRESS PULSEPRESS 056 mmHg PULSE 082 bpm 158 056 101 22
21. en the cuff will be exhausted rapidly PRINTER COVER It protects the printer 9 AUTOMATIC CUTTER printing paper let out slot Printing paper is automatically cut off when it comes out through the slot CUFF It wraps and releases the arm automatically for measurement 17 ARM REST When the arm is placed on the cuff the arm supporter sustains the arm and makes the right position 12 HUMAN SENSOR option When a user approaches power is automatically turned on and vice versa 8 RFID CARD READER option When RFID card is applied it reads information in it and stores the measured results MAGNETIC CARD READER option When magnetic card is swiped it reads information in it and stores the measured results 15 The cuff and the buttons START and STOP button of this device are located at reverse side by R and L type FRONT PART 4 DIASTOLIC DISPLAY 3 SYSTOLIC DISPLAY 6 TIMER 6 PULSE DISPLAY 43 RFID CARD READER 40 CUFF 44 MAGNETIC CARD READER E pr A E 2 STOP BUTTON EMERGENCY _ po 9 PAPER OUTPUT 8 PRINTER COVER 2 HUMAN SENSOR Printer card reader and human sensor are optional ID card can be issued either by the machine manager or by the manufacturer of the model The card stores six previous measured results and can contain seven measured results with the current one altogether When the model manager writes the card please refer to the manual and
22. etic Card reverse monitor 126 mmHg 4 26 mmHg 070 mmHg 070 mmHg MEANPRESS 088 mmHg MEANPRESS 088 mmHg PULSEPRESS 056 mmHg PULSEPRESS 056 mmHg PULSE 082 bpm PULSE 082 bpm 158 The result is pre hypertension Refer to the results and consult to physician Ns FATNESS 22 4 PULSE WAVE PATRI M ec The result is pre preparan Refer to the results and consult to physici cian Ni Pe PULSE WAVE PATTERN 179 059 1 179 DIASTOLIC PULSE mmHg oon Tm 36 3 RFID card Machine manager can issue cards through supportive card issuer in machine s delivery you can issue it yourself When machine manager issues cards please refer to card issuer or program manual 1 Setting 4 I d aS In card s using you should set CARD ON OFF in the rear part by ON 2 Measurement D card recognition You hold your card and then touch on card reader If card is recognized normally it sounds Ttiriring and it becomes in the state of being ready for measurement In connected reverse monitor ID stored in a card is displayed in the rear monitor Then you can put weight and height in the reverse monitor 2 Measurement If you finish recognizing card voice and message Please press the start button comes out Push the start button and then b
23. l removal 1 Power supply Screen display upon Pass Fail 2 Display No abnormality and Pass Fail mm o os Copy this sheet for use Accessories Electrical Check Performance If repair is required write down so in the Remarks column 45 Daily Check List Management No item __ Inspection Subject Judgment Remarks Visual Check 1 Enclosure No scratch crack Pass Fail deformation and rust Mainframe No scratch and damage Kept in proper place Pass Fail Mechanical Check Smooth operation Pass Fail T ainframe D ensnder omooth operation with no abnormal sound Accessories Power cord operation Pass Fail Electrical Check Power supply S display UPON Pass Fail Performance Display a ane Pass Fail General Judgment Passfal _ instalation place Baieofpurchase Check date NENNEN Checked by 221 Approved by Copy this sheet for use If repair is required write down so in the Remarks column Service center TEL 82 2 587 4056 82 53 856 0993 If the problems continue call the service center When you ask for service the manufacturer s label serial number date of original purchase and explanation of malfunction will be required x For purpose of improvement specifications and subject to change without notice MJAWON MEDICAL www jawon com Our company name will be changed to JANEX MEDI
24. monitor D Put support of reverse monitor in the direction of arrow 2 Attach reverse monitor into reverse monitor support as above 3 4 Put guide board in the direction of arrow and then complete it 2 Connect Connect reverse monitor and a blood pressure monitor to the rear BACK MONITOR PORT the body using cable 3 Composition D LCD display Shows information and proceedings Also marks result such as B M I and fatness after completing the measurement 2 Indicating part of systolic blood pressure Indicating the measured systolic blood pressure 3 Indicating part of the diastolic blood pressure Indicating the measured diastolic blood pressure 4 Indicating part of pulse Indicating the measured pulse 5 ID button Used when putting user s ID number 3l 6 Weight button Used when putting user s body weight 7 Height button Used when putting user s height Numbers and button Used when putting numbers such as ID body weight height etc Use button in order to put a decimal point in case of body weight height For example if body weight is 68 9kg put weight button 6 8 9 in order 9 Print button Press in the result screen and the measured result is printed STOP button When you push a button while putting some inform
25. nnect a computer or other external options to the unit Connect the RS 232C cable both to port of the unit and to the computer jack or other external options See the picture 292 4 SETTING TIME AND DATE Turn on the unit Open the printer cover e Sequence is HOUR MINUTE gt MONTH DAY YEAR D Press SET button then indicator will blink At that time press PRINT button Its counts that have been measured since keeping button ON will be printed 2 Press SET button once again First 2 figures will blink 3 To set the current hour press PRINT button to make the number goes up or press FEED button to make the number goes down D After setting the hour press the SET button again 2 In this time last 2 figures will blink 3 As the same way as above set the current minute with PRINT and FEED button D After setting the minute press SET button again 2 First 2 figures will blink 3 Set the current month with PRINT and FEED button D After setting the month press SET button again 2 Last 2 figures will blink 8 Setthe current day with PRINT and FEED button D After setting the day press SET button again 2 First 2 figures will blink 8 Setthe current year with PRINT and FEED button lf you want to measure blood pressure during setting the date and time press STOP button Then you can measure again immediately You should set all data at once hour minute month day and year
26. o be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS a statement that portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT N42 Please consult a physician or a trained health professional for interpretation of measurement results A 13 No phthalates are used for this product and its container A 14 The cuff is not made with natural rubber latex 1 Measurements may be impaired if this device is used near televisions microwave ovens X ray equipment or other devices with strong electrical fields To prevent such interference use the meter at a sufficient distance from such devices or turn them off 2 Incorrect operation or failure of user to maintain the unit spares the manufacturer or his agent of the responsibility for system s non compliance with specifications or responsibility for any damage or injury This manual is made for informational purpose and this manual and product are not meant to be a substitute for the advice provided by your own physician or other medical problem You should not use the information contained in the product for diagnosis or treatment of health problem or prescription of medication by yourself If you have or suspect that you have a medical problem consult with your physician promptly Defective unit or accessories must be packed in the replacement cartons to be shipped off from you to our company
27. our service center We will provide you with detailed instructions 1 INTEDED USE EASY X 800 R L Automatic Blood Pressure Monitor is designed to measure systolic and diastolic blood pressure and pulse rate of Persons who are 18 years and older using the oscillometric method on a cuffed arm EASY X 800 L measure the Left arm EASY X 800 R measure the Right arm Target user Persons who are 18 years and older e This medical device is not for home use 2 WORD DEFINITIONS To ensure safe operation and long term performance stability it is essential that you fully understand the functions operating and maintenance instructions by reading this manual before operating your unit Particular attention must be paid to all warnings cautions and notes incorporated herein The following conventions are used throughout the manual to denote information of special emphasis Important information to indicate any possible hazard which can cause severe personal injury of death from substantial property damage when ignored Important information to indicate any possible hazard which will or can cause minor personal injury or property damage when ignored Important information to notify to the user about installation operation or maintenance information which is important but not hazardous Warnings against hazard are not to be included under the NOTE signal word 3 CLASSIFICATION AND COMPLIANCE 1 This device is classified as Clas
28. r its authorized dealer for service 4 The unit has previously been adjusted in the factory for optimum performance O Do not attempt to adjust switches or any other things except those specified in this manual for operation A 5 If you have experienced any trouble with the unit switch it off immediately and contact our company or its authorized dealer for assistance 6 If you plan to connect any device of other manufacturers electrically or mechanically to the unit contact our company or its authorized dealer for instructions before doing so When you connect computer or other system to the unit RS 232C the attached systems should be those certified by IEC 60950 or equivalent standards for data processing equipment Configurations shall comply with the system standard IEC 60601 1 2005 Everybody who connects additional equipment to the signal input part or signal output part configures a medical system standard IEC 60601 1 2005 If in doubt consult the A S department of local distributor eS T 7 Avoid the following environments for storage Where the ambient temperature falls 20 C or exceeds 60 C Where the atmospheric pressure falls below 7OkPa 700 or exceeds 106kPa 1060mbar Where the humidity is over 95 non condensing Where the unit is exposed to spray or splashing water Where the unit is exposed to dust Where the unit is exposed to water vapor Where the unit is exposed to salty atmosphere
29. s 1 type BF against electric shock Ordinary equipment without protection against ingress of water Equipment not suitable for use in presence of a flammable anesthetic mixture by standard of EN 60601 1 2006 Basic safety and essential performance of Medical Electrical Equipment 2 This device is complied with Class A for Noise Emission Level B for Noise immunity by standard of IEC 60601 1 2 2007 Electromagnetic Compatibility Requirements 3 This device is complies with the EN 1060 1 1995 A2 2009 Non invasive Sphygmomanometers general requirements as well as EN 1060 3 1997 A2 2009 supplementary requirements for electro mechanical blood pressure measuring systems 4 SAFETY PRECAUTIONS This device is designed and manufactured with consideration of safety of the operator and subject and also to the reliability of the unit The following precautions must be observed for additional safety A 1 The unit must be operated only by or under supervision of a qualified person with our company or our distributors 2 This device is specified as Class 1 type BF unit under the standard of IEC 60601 1 2005 Safety of Medical Electrical Equipment Do not touch or handle inner side of the system at any time The INTERNAL ELECTRICAL POWER SOURCE is to be used if the integrity of the PROTECTIVE EARTH CONDUCTOR or the protective earthing system in the installation is in doubt 3 Do not modify the unit If any modification is needed ask our company o
30. spital environment UT is the a c mains voltage prior to application of the test level 11 3 Guidance and manufacturer s declaration electromagnetic immunity 2 The EASY X 800 is intended for use in the electromagnetic environment specified below The customer or the user of the EASY X 800 should assure that it is used in such an environment Compliance Immunity test IEC 60601 test level uw Electromagnetic environment guidance eve and RF Portable mobile communications equipment should be used no closer to any part of the EASY X 800 including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2V P d 1 2 P 80 MHz to 900 MHz Conducted RF 3 Vrms 3 Vrms IEC 61000 4 6 150 kHz to 80 MHz d 2 NP 900 MHz to 2 5 GHz where P is the maximum output power Radiated RF V m V m rating of the transmitter in watts W IEC 61000 4 3 80 MHz to 2 5 GHz according to the transmitter manufacturer d the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol 12 1 At 80 MHz and 900 MHz the higher frequency range applies
31. to the power supply equipped with the protective grounding When connecting adaptor place the arrow mark of adaptor connection part up and correctly stick it in the socket on the rear of the main body Wrong connection could be a fire hazard 2 LOADING THE PRINT PAPER o Check and see if power is turned on Q Turn the nut with a driver on the groove in the middle on the lower printer cover clockwise to 90 degrees and open the cover Load the print paper as shown in the picture Insert the paper edge deep under the black roll then it comes out above the CUTTER Balance the paper in the right place Cut the paper by pressing the FEED button o 0 9G Close the cover and turn the nut counterclockwise back 2 Being thermal type printing is photocopied on one side of the paper slippery side without using printing ink Please check remainder of the paper always and then replace it Please use exclusive paper 58mm Keep paper rolls in a dark and ventilated place Avoid any dust on the paper Do not pull the paper during printing It could cause jam When printing paper is not loaded in correct place it may cause the malfunction of the printer or paper will be shoved out After the exchange of paper to the printer cover does not close properly the alarm sounds LED on the Err is displayed Please check the status of the printer cover 3 CONNECTING PORT RS 232C To transmit the data co
32. vered with 8kV Air 8 Air synthetic material the relative humidity should be at least 30 Electrical fast 2kV Power 2kV Power Mains power quality should be that of transition burst supply lines supply lines a typical commercial or hospital IEC 61000 4 4 1kV 1kV environment 10 Input output lines Input output lines 1 differential 1 kV differential Mains power quality should be that of Surge mode mode IEC 61000 4 5 2 kV common 2 kV common mode mode lt 5 UT lt 5 UT gt 95 dip in gt 95 dip in UT UT for 0 5 cycle for 0 5 cycle Mains power quality should be that of a typical commercial or hospital environment Voltage drops 40 UT 40 UT a typical commercial or hospital dips and 60 dip in UT 60 9o dip in UT environment If the user of the EASY fluctuations of for 5 cycles for 5 cycles X 800 requires continued operation input power 70 UT 70 UT during power mains interruptions it is supply line IEC 30 dip in UT 30 dip UT recommended that the EASY X 800 61000 4 11 for 25 cycles for 25 cycles be powered from an uninterruptible 5 UT 5 UT power supply or a battery gt 95 dip in UT gt 95 dip in for 5 sec UT for 5 sec Magnetic field of Power frequency magnetic fields commercial should be at levels characteristic of a frequency 50 60Hz IEC 61000 4 8 typical location in typical commercial or ho
33. y and the coin slot with RS 232C cable to transfer the data 6 BACK MONITOR PORT option Connect the main body to the reverse monitor cable USB PORT Connect the main body and USB cable SENSOR ON OFF Human sensor is switched on and off 9 SOUND ON OFF Music and voice output functions are activated with the switch ON and vice versa CARD ON OFF Card is usable when the switch ON and vice versa 1 PRINT ON OFF Measured results are printed out when switched ON and vice versa VOLUME ANNOUNCE ON OFF It controls volume output when switch is on while all volume is OFF 3 REVERSE MONITOR optional You can see the ID No B M I and Fatness as well as Blood Pressure on the reverse monitor INFORMATION BOARD FIXER Fix the information board here 18 1 While sound switch is activated on so sound is functioning place the VOLUME ON OFF switch to OFF for deactivation of voice message and music play 2 Printer card reader human sensor and reverse monitor is optional 3 The operator should not touch both USB port and the patient s body simultaneously The operator shall not contact the parts SIP SOP and the patient simultaneously and SIP SOP shall be available to operator only REAR PART BOARD FIXER 13 REVERSE 1 POWER i WI 2 VOLUME POWER v 5 COMMUNICATIO 17 PRINT ON OFF PORTS PORT 9 SOUND ON OFF USB PORT 4 EARTH 2 10 CARD ON OFF