Home
Instruction Manual
Contents
1. 2 extend your senses INSTRUCTION MANUAL TEMPERATURE SENSOR TG8 Pt 1000 3850 The temperature sensor with a cable for measuring temperatures of gaseous and liquid substances ranging from 50 C to 200 C intended for universal application Instruction Manual in Czech language is available here www cometsystem cz sondy htm or can be obtained from your supplier Manual v esk m jazyce je dostupn zde www cometsystem cz sondy htm p padn na vy d n u sv ho dodavatele SENSIT s r o koln 2610 756 61 Ro nov pod Radho t m ID No 64087484 VAT No CZ64087484 Phone 420 571 625 571 Fax 420 571 625 572 Company is incorporated in the Companies Register at the Regional Court in Ostrava Section C File 13728 sensit sensit cz www sensit cz 2205 2 09 14 2205 1 Legal regulations and standards e aws regulations and technical standards referring to occupational safety must be followed during installation e Electrical connection of the detector may only be carried out by a competent person with electrician qualification who is familiarized with the Instruction Manual in detail e he Instruction Manual is part of the product and it is necessary to keep it for the entire service life of the product e he Instruction Manual must be transferred to any other owner or user of the product e he disposal must be performed in compliance with the Directive 2008 98 ES of the European Parliament and of the C
2. ation 2 Install the sensor in the measured location or insert it in the thermowell and ensure fix installation of the sensor to prevent its movement 3 Connect the wires of the supply cable to the evaluation unit according the wiring diagram The supply cable shielding is not conductively connected with the external housing of the sensor or with the element 4 After installation and connection to the consequential electrical measuring device the sensor is ready for operation The sensor does not require any special manipulation or maintenance Wiring diagram a R t red white two wire Technical parameters Type of element Housing material stainless steel 17240 Housing length tos lt 7 sec in flowing water gt 0 2 m s Dielectric strength 900 VAC according to EN 60730 1 Housing diameter 5 0 1 mm Supply cable type Supplycablelength o o O Maximum water flow speed when Thermowell length up to 60 mm measuring temperature in piping with Thermowell length gt 60 to 100mm aG 2 m s Insulation resistance gt 200 MQ at 500VDC 25 3 C 2 CG thermowell Thermowell length gt 100 to 160mm Maximum speed of air and water vapour Thermowell length up to 60 mm flow when measuring temperature in Thermowell length gt 60 to 100mm piping with thermowell Thermowell length gt 100 to 160mm Weight 0 05 kg 1m for two wire connection the influence of the cable resistance must be add to measured value for examp
3. concentrations at high temperatures weak organic acids with high concentrations and high temperatures chlorinated hydrocarbons and undiluted alkaline substances Failure to follow the said recommendations will negatively affect measurement accuracy reliability and service life of the temperature sensor Declaration of conformity SENSIT s r o provides the product with the EU CE Declaration of Conformity issued according to Act No 22 1997 Coll as subsequently amended The product is in accordance with the following directives e European Parliament and Council Directive 2011 65 EU of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Product safety and technical parameters were evaluated according to the following standards and norms as amended e EN 60751 EN 60529 EN 60730 1 EN 60730 2 9 Sensor description The sensor consists of a metallic housing with the sensing element inside and a supply cable The sensor housing is made of stainless steel DIN 1 4301 The sensors are connected as two wire probes The supply cable has external silicone insulation and is shielded The shielding is not connected with the housing or with the temperature element The length of housing can be selected from 40 to 200 mm Sensor installation 1 If the sensor is used in combination with the thermowell screw the thermowell in the welded on piece on the piping or in the specific threaded loc
4. from defective performance will be governed by the applicable legislations and the applicable Business Terms and Conditions of SENSIT s r o and this Warranty Certificate Date of sale confirmation Serial number
5. le at temperature 25 C must be add the value 0 027 C 1m in the case of fixed location the housing and cable the sensor can be used from 80 C Operating conditions e temperature round the supply cable 50 C to 200 C 80 C for fixed location e relative humidity of the surroundings 10 to 100 96 e atmospheric pressure 70 to 106 kPa Storage e Ambient temperature 5 to 40 C e Humidity 5 to 85 Delivery Each delivery contains the following unless otherwise agreed by the customer e Sensor according to purchase order e Instruction Manual including Guarantee Certificate e Delivery Note Complaints and repairs Guarantee and after guarantee repairs of sensors are ensured by the manufacturer The product must be delivered including a copy of the Guarantee Certificate duly packed and fit to shipment so as not to get damaged during transportation GUARANTEE CERTIFICATE The product is covered by guarantee for 30 months from the date of purchase In this period the manufacturer will remove all material or manufacturing defects arisen demonstrably during the applicable warranty period The manufacturer is liable for the technical and operational parameters of the product given in the user manual Any identified defects will be claimed by the buyer without undue delay after their identification or as appropriate after the buyer was able to identify them during his routine care A completed Warranty Certificate
6. measurement in chemically non aggressive environments the using must be chosen with regard to temperature and chemical resistant housing and a cable Recommended use and location of sensors e Operating position is arbitrary e Sensor must be placed into protective thermowell for continuous temperature measurements of liquid substances e he recommended minimum immersion of the sensor in the medium is 80 mm Warnings and restrictions The sensors must not be used for measuring in locations Where the specified technical parameters and operating conditions are not adhered Where the sensor is exposed to mechanical action With explosion hazard the supply cable is not resistant to flame propagation For measuring temperatures of subjects under voltage With chemically aggressive environment Where the sensor is exposed to permanent immersion in the liquid It is not suitable to use the sensors for measuring temperature in locations e Where sufficient contact with the measured fluid is not secured low submersion of the sensor effects of the surroundings e Where the supply cable might run parallel to mains cables risk of interference signal induction and the measurement results may be influenced the safe distance from mains power cables when cables run parallel can be as much as 0 5 m according to the nature of interfering fields e Where the sensor might be exposed to effects of strong organic and inorganic acids with medium and strong
7. ouncil on waste and the Directive 2012 19 ES of the European Parliament and of the Council on waste electrical and electronic equipment WEEE e he sensors are delivered in packages which guarantee resistance to mechanical influences and that meet the conditions with the European Parliament and Council Directive 94 62 ES on packaging and packaging waste e All SENSIT s r o products are checked for their function and the compliance with their specifications usually by comparison with reference measuring instruments These reference instruments are traceable to the Czech national standards and the measurement uncertainty is considered for the measuring processes Application The temperature sensors TG8 are designed for measuring temperatures of gaseous and liquid substances The temperature range for application of the sensor is 50 C to 200 C in the case of fixed location the housing and cable the sensor can be used from 80 C The sensors may be used for all control systems compatible with the Pt 1000 temperature sensor with a temperature coefficient of 3850 ppm C They meet the ingress protection IP67 according to the EN 60 529 standard The temperature sensors are designed for universal application The sensors in combination with JTG8 thermowell can be used for measuring temperatures in piping and simultaneously as pressure equipment in terms of the Pressure Equipment Directive 97 23 ES The sensors are suitable for temperature
8. with a brief description of the defect plus the product must be submitted with the claim Warranty does not cover a product e hat was damaged during transport and inappropriate storage improper commissioning and or that has been used for a purpose other than specified e hat has been used in an improper manner inconsistent with the user manual and or generally applicable technical standards or safety regulations e hat is worn or damaged as a result of normal use of the product without loss of its operational characteristics and guaranteed technical parameters e Into which unskilled intervention unauthorised structural or other changes reprogramming resetting of set parameters etc have been made e hat is mechanically damaged e g by fall being hit by a hard object cleaning with unsuitable agents power cord tearing breaking breaking or other damage of individual product parts e hat has been exposed to adverse external influence e g object intrusion wrong supply voltage influence of chemical processes electrical surge obviously burnt components or printed circuits dusty dirty aggressive or otherwise unsuitable environment except normal variation e hat has been damaged by an incidental or natural disaster or as a result of natural or external phenomena such as storm fire water excessive heat e That is claimed without the Warranty Certificate or nameplate Rights and obligations regarding the rights arising
Download Pdf Manuals
Related Search
Related Contents
Manuale di installazione 取扱説明書 - 株式会社三明 1万字程度の要約については、こちらをご覧下さい。 Real Time Developer Studio Installation manual FRAMTID - Traveltruck Samsung Combinato MC32J7055CT User Manual 取扱説明書 - ホライズンフィットネス HORIZON FITNESS Electrolux EOD63142 User's Manual comBIND 500e Operating Instructions Baixar manual Copyright © All rights reserved.