Memograph M brochure
Contents
1. Digital 2 Dos 0h17 11 Digital 1 Digital 1 off Digital 2 Los 9 0 SD E Analog 1 0 0 Analog 2 52 8 Analog 3 50 0 Analog 4 Ene 1033 4 stek Intelligent videographic recorder Memograph M Calculate and solve tasks Mathematics and logic With the optional mathematics package eight additional channels are available Individual channels can be combined with each other and then calculated using vari ous mathematic functions The calculated mathematics channels are treated like real channels irrespective of whether they are or connected conventionally or via a fieldbus The formula can be an arbitrary com bination of arithmetic calculations and logical operations Analog digital or also mathematics channels already active can be used Linearization Up to 32 linearization points for all active analog inputs can be entered directly or by means of the PC software ReadWin 2000 Integration totalizer By using the integration totalizer func tion the quantity can be calculated in m3 from an analog signal e g flow in m3 h This can then be displayed as day week month year and total values Automatic signal analysis The Memograph M automatic signal analysis provides easily read conditions Actual and previous signal quantities and peaks are listed in tables This gives a fast overview of for example the last shift the actual day the last month etc m Automatically calcul
2. 21 CFR 11 m Modular Simple expansion to 20 universal and 14 digital inputs or 12 relays m Flexible Selectable display mode Brand new analog instrument display and circular chart display m Limitless Integrated Web server fieldbus PROFIBUS Modbus standard protocols and interfaces such as USB TCP IP OPC Ethernet are supported Informative Event search automatic signal evaluation m Practical 158 mm installation depth IP65 NEMA4 plastic front bezel Concise Alarm management with all active acknowledged and historical alarms Re calibration of a measurement chain can be done in an installed system Functions and design Generous basic features flexibly expandable As the only device on the market in this class Memograph M can internally record up to 20 universal inputs analyze the raw data and store analog values counter values or quantities and simultaneously up to 6 different Loop power supply A sensor power supply 200 mA 24 V makes direct connection of a loop powered or 4 wire sensor possible This saves time and costs and simplifies the wiring requirement Important information at a glance due to the large 7 display The process values and event messages are shown on the high definition 7 TFT display and can therefore be easily read from a large distance thus making direct access on the spot for current and historical production data pos sible for the user The large screen rep
3. User administration Acknowledging messages Miscellaneous X Back OK ee er aes Analog 1 0 0 100 0 Cancel system integration and communication All units are equipped with a number of different communication possibilities Interfaces connect these to PC modem or PLC and will also connect them to bus systems The units can then be remote controlled and the measured values read out Whether as a stand alone solution or a part of an existing system the units operate individually or as redundant monitoring and recording systems This means that they increase security and avoid process downtime even during network breakdowns OPC based software P view SPS PLE GSM Modem ReadWin 2000 _ USB interface In the standard version the device has two front mounted USB interface ports The interfaces can be used differently The USB host interface serves for data transmission to a USB stick The USB function interface serves for the direct connection with a PC laptop computer Using this interface the stored data and device configuration can be accessed RS232 RS485 The serial interfaces serve for the connec tion of either a modem RS232 for remote monitoring of the device or for the com munication with a PC laptop computer By using the RS485 interface a simple serial network can be built up max 32 devices Internet Web Browser D ot ee et T Oe Rea
4. _ a en Analog 2 Analog 3 0 0 100 0 Extras Analog 6 0 0 100 0 C Extras Events History Search JACM DO igital 2 07 03 2007 14 36 Analog 2 N 44 29 33 Analog 3 78 6 y Analog 4 ra 4344 7 Pcs Analog 5 141 2 c Analog 6 518 7 c Digital 1 on Events History Search Extras aa ia Circular chart display Memograph M leaves the choice to the operator at the touch of a button Up to 10 groups each with a mix of maximum 8 channels can be displayed 12 03 2007 15 44 ID U1 20 03 2007 17 01 Events History Search 12 03 2007 15 45 Search Group 1 Event log Audit Trail 061 Setup has been changed User1 U1 Firmwareupdate GMUOOOA 00 00 1 Netz Ein User1 U1 Netz Aus User1 U1 Digital 1 H gt L User1 U1 Digital 1 L gt H User1 U1 Digital 1 H gt L User1 U1 Digital 1 L gt H User1 U1 Digital 1 H gt L User1 U1 Setup wurde ge ndert User1 U1 Setup Gruppe 1 ge ndert User Setup wurde ge ndert User1 U1 0461 Anoemeldet Usert U1 Cancel Go to Event log book Extras 12 03 2007 15 42 ID U1 1820 0 0 0 User1 12 03 2007 15 41 38 12 03 2007 15 41 30 12 03 2007 15 41 30 07 03 2007 15 52 33 07 03 2007 15 52 21 07 03 2007 15 52 20 07 03 2007 15 52 18 07 03 2007 15 52 17 07 03 2007 15 52 16 07 03 2007 15 43 24 07 03 2007 15 43 24 07 03 2007 15 33 40 07 03 2007 15 33 40 07 03 2007 15 32 36 07 03 2007 15 32 36 Digital 1
5. and stored by Memograph M Via this interface Memograph M can be connected to a master PC or a PLC control system Typical application areas m An electronic data storage makes the traceability of the pro cesses economical and the quality assurance possible e g in the production of metals plastics ceramics tires cables electronics etc m Overview of critical parameters during production packing and cold storage of food drinks and dairy products m Supervision and recording of consumption rates filling levels and overflows in tank systems m Supervision of dangerous emissions of liquids waste and gasses used in the production and petrochemical processing plants Remote monitoring of deep wells mineral water sources and pumping stations Storage and invoicing of energy gas and liquid consumption in industry m Storage and supervision of the performance characteristics of turbines boilers and reactors in power stations Housing versions Panel mounted device Memograph M with IP65 NEMA4 plastic front bezel for panel installation use Desk top housing Portable version for laboratory and service Endress Hauser m Supervision of critical parameters in drinking water filtration systems and rivers m Supervision of the chemical and biological load in the sewage of industrial plants and municipalities m Data acquisition in OEM versions for independent machine plants such as filling machines milk col
6. JW wi ee Se ea Level Pressure Flow Temperature Liquid Registration Systems Services Solutions Analysis Components Memograph M Graphic Data Manager USB 0 Analog 1 f Ee 20 Events History Search Extras ee 2 0 0 100 0 store visualize analyze and communicate process values Generous basic features flexibly expandable Important information available at a glance due to the large 7 17 cm display Highest data security and FDA conform user administration Simple data exchange using standard interfaces such as USB Ethernet or OPC Endress Hauser People for Process Automation Graphic Data Manager Memograph M The new generation in videographic recorders As one of the world s largest industrial recorder manufacturers Endress Hauser has been supplying strip chart recorders data loggers and paperless recorders since 1980 that is many years of valuable experience and more than 150 000 installations world wide State of the art data recording With the Graphic Data Manager Memograph M Endress Hauser introduces its new videographic recorder The innovative device is impressive because of its high functionality modular construction and its intuitive operator concept The ideal fields of application for Memograph M are in the process measurement in the water waste water power and the food as well as pharmaceutical industries The functionality flexibility secure data recording the informative mea
7. ates averages minimum and maximum values for the analog measurement points m Calculates intermediate daily monthly yearly reports m Shows counter values operating times and quantities Expert Inputs Maths Maths 1 active Calculation active Yes Channel ident Formula lee cone 1 2 2 4 elelr ale of es Be ea TE 30020 000 Fault Copy se Save both time and money with these functions m Basic arithmetical operations combine analog measurements m rigonometrical as well as absolute value root and square functions FO calculations e g in sterilization processes m Factors and constants complete the calculation functions m Channels calculated mathematically can be combined cascaded m Square root extraction linearizes squared signals Search function Answers to all questions The search for certain information was to this day a very time and cost consuming task In the future leave this up to the Memogaph M Graphic Data Manager It will answer all questions asked When did the temperature rise above 80 C What happened yesterday at 12 00 o clock m When was the filling stopped How long was the plant down u When how long did the pumps run How have the signals developed over a longer time period 07 03 2007 16 46 Search filter All events Alarm limit violation On off events Setup change Power on off Service External memory
8. dWin 2000 Pii aau SD card USB stick CSV dat Ethernet connection Using this interface paperless recorders can be connected to the local area network LAN By using the TCP IP protocol the measured data from the connected units can be accessed via any Internet Intranet compatible PC or laptop computer and the delivered ReadWin 2000 PC software Stored data can be visualized and with the help of the PC software transmitted to the network compatible database The IP address is set up directly in the unit or automatically from a DHCP server Remote monitoring modem use All functions available via serial link can of course also be used with modem con nection The videographic recorder can therefore be monitored worldwide MS Excel Integrated web server Standard web browsers like MS Internet Explorer permit the simple access to instantaneous measured values Simple process data exchange using the OPC Server OPC OLE for process control is the industrial standard for exchanging process data on MS Windows based computers The advantage With the Endress Hauser OPC server it is possible to integrate process data from the units into most standard visualization or process control systems Modbus Slave RTU TCP Option By using the internally available Modbus interface a total of 40 external analog in puts and 14 digital inputs can be recorded
9. lecting stations wine sterilization plants milk pasteurization and cheese production m Multi channel gateway between Intranet Internet visualiza tion software and the sensors in the process with or without redundant data recording Conclusion Wherever process parameters have to be recorded and analyzed visualized supervised the new Memograph M is the answer Field housing Memograph M in a field housing IP65 for wall mounted applications suit i dress Hauser 54 male 2 0 0 1 Further documentation Recorder brochure FAOQI4R 09 en 20 0 46 0 0h00 00 o m Graphic Data Manager Memograph M technical information TI133R 09 en Instruments International Endress Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel 41 61 715 81 00 Fax 41 61 715 25 00 http www endress com info ii endress com INOO05R 09 en 03 07 71041159 RD INDD CS2 12 06 1 1 Endress Hauser People for Process Automation
10. n be used as a ring or stack memory or USB memory stick m Minimum maximum and average values as well as envelope values quantities and events are stored in predetermined memory time cycles 00 00 0 0 Events History Search Nia PUT Le SAO The following functions guarantee compliance with the FDA 21 Part 11 and therefore the traceability of all process sequences m Integrated user and rights management m D password electronic signature m Mechanisms that request the user to change his password regularly m More than 50 users with various access levels and rights can be entered m Access protection m Access block on entry of 3 invalid login attempts SD card in industrial standard High data integrity and failure security Low intrinsic heating u 2 million write delete cycles per block m High reliability MTBF gt 3 million hours Data transmission to PC via ReadWin 2000 software The recorded values are only stored in the PC database after a fault free transmission Any possible manipulation of the data is recognized and subsequently highlighted The data can of course also be exported to other programs e g MS Excel without changing the original protected data Analog 6 919 1 Digital 1 of Digital 2 Low 0 0 9 0 All operation steps and messages generated by the unit e g Login out Set up changes Alarm set point violations Recalibration Text e
11. ntry comments Events and power failures These are placed and stored in the Audit Trail and time stamped with allocation to the respective responsible user in both the unit and the ReadWin 2000 PC software Intelligent alarm and limit manage ment Reliable and punctual recognition of limit value violations safeguards high quality and reduces costs Memograph M supervises analog values and counters Flexible possibilities to save on external components and time consuming wiring m 100 alarm limit set points can be al located to the channels m Pre alarm and main alarms can be selected m Adjustable hysteresis m Short time peaks can be ignored m Device internal switched outputs up to 12 relays can be freely allocated These can be allocated to individual alarm annunciators e g siren lamp Alternatively valves or pumps can also be controlled This saves additional equipment for the alarm annunciator or sequence control m Freely adjustable event report texts Acknowledgeable alarm violations make sure that the violation is recognized m Displaying the limit value as a channel related colored line on the display Flexible display mode selection Visualization For different types of data different graphic displays are often re quired Are only the analog values to be displayed or should these be combined with digital signals 12 03 2007 16 01 ID U1 Analog 1 e a _ _
12. resents a number of different display formats such as curves bar graph but also circular chart and analog instrument display Depending on the requirements mixtures of these can also be set up by the user Active channels can be as signed into 10 groups For clear identification these groups can be assigned individual names e g temperature boiler 1 or daily average values for all boilers operating times or switching states By using PROFIBUS or Modbus the device can be extended to 40 channels and be connected to SCADA and PLC systems The processing of arbitrary nonlinear signals is no longer a problem because a 32 point linearization table can be defined for each individual input 2 analog outputs provide additional flexibility Front end operation of the device Operation of the device is dialog based via menus using a navigator jog shuttle in combination with 4 pushbuttons Alternatively Memograph M can be operated using an external keyboard USB Another highlight is the integrated on line help which almost makes the published user manual superfluous 09 0 0 100 0 ee p 7 3 Operation using PC Software Set up and operation of the device is also possible via the ReadWin 2000 PC software Set up and communication is done using m USB interface m Ethernet m Serial interface a SD memory card Set up data can also be stored on an SD card or USB stick and printed out for archiving purposes De
13. surement evaluation and brilliant measurement display means that the applications are limitless As a standalone system or as an efficient system compo nent Memograph M is the ideal solution for every task The device is easy to operate and offers a multitude of possibilities to save costs and simplify data storage Memograph M is the Window to the process m Selectable easily understandable screen display mode Front end trend value monitoring with out complex PLC SCADA software Independent data recording system guarantees manipulation protected data recording for the most demanding tasks Off line data evaluation and reports in standard paper size printouts for process and cost optimization m No programming only set up m Simple process traceability m Compliance with quality parameters can proven at any time As the success story of the Memograph recorder family shows this equipment offers the greatest measure in reliability and flexibility These recorders are applied in almost all areas of industry such as food amp beverage pharmaceuticals environmental technology power pulp amp paper primaries chemical and oil amp gas Advantages of Memograph M a Brilliant 7 TFT display as a front end display for optimum readability m Fast 100 msec scan rate for all channels high speed memory cycle of 100 msec m Secure Security package with user defined access rights and electronic signature FDA
14. vice set up can be transmitted to the device directly from a memory card Text input Notes and comments can be allocated to the recorded signals and subsequently saved Operation language The operating language e g German English French Italian can be easily changed directly at the device even during operation Compact and robust The required installation depth amounts to only 158 mm thus narrow control panels can be used This reduces costs and materials especially for new installa tions The robust front bezel plastic materials ensures the IP65 NEMA4 protec tion class Graphic Data Manager Memograph M High security standard By fulfilling the requirements laid down in the 21 CFR Part 11 electronic record ing and signatures are given an identical legal status as traditional documentation and hand written signatures All the old problems with the time consuming tradi tional recording paper jam paper and pen change are a thing of the past electronic evidence is the new direction Data security The Graphic data manager completely archives process curves and events Stored data is not lost not even during a power down Details at a glance m Large internal memory capacity of 256 MB m The internal memory operates as a ring memory according to the FIFO principle first in first out m Optimal storage utilization by data compression m Additional storage on external industrial grade SD cards ca
Download Pdf Manuals
Related Search
Related Contents
OKI® B8300 Warranty, Safety and Regulatory Nuendo – Mode d`Emploi H.264 POE VIDEO SERVER User`s Manual User guide Bedienungsanleitung Guide d'utilisation Manual del PRO COMP SUSPENSION Part # 56708/56708MX 2003– 2008 (GIAS) by Dr. Raj Mehta MANUAL DE INSTALAÇÃO Samsung CLX-3185 User Manual CT-410WR 取扱説明書ダウンロード(1.15MB Copyright © All rights reserved.