AuraSys™ L-2 User Guide - AxtraxNG Software

image

Contents

1. 3 5 1 Disarmed Mode In Disarmed mode Idle mode if it is not in programming or memory trouble display modes the indicators behave as follows Memory and trouble indicators are continuously lit or off according to the status and per their display modes The ALARM indication is off The buzzer generates warning beeps in trouble conditions if trouble beeps are set and in trouble condition and generates key beeps on keypad operations You can disarm a panel whether alarmed or not from the L 2 panel as follows By using the key switch L 2 By entering code L 2K you can disarm the system AuraSvs M L 2 User Guide 13 Operating the AuraSvs L 2 Svstem Oncethe code entry is approved by the control panel the Disarm Ready indicator turns on the system updates the indicator status the buzzer emits the acknowledge sound and the system returns to idle state 3 5 2 Armed Mode Zone indicators do not behave in the same way in Armed mode as they do in Disarmed mode The system accepts arming requests from the panel when disarmed Arming the system through the L 2 is done by toggling between Armed Away and Disarmed by entering a code in the L 2K or turning the key in the L 2 3 6 User Modes There AuraSys L 2 system supports a single User mode only in contrast to the L 4 and L 6 models which support additional modes 3 6 1 User A user code is assigned for arming disarming the system only Up t
2. Arm Away single pulse Disarm dual pulse Emergency alarm Trouble alert 4 9 Entry Exit Delay Options Entry and Exit actions delay the alarm mode and allow the system to ignore zone violations as described below 4 9 1 Entry Delay Entry delay allows a user a grace period for the time it takes to open the door reach the control panel and disarm the system If a zone of type Delay is violated while the system is armed except Instant Arming the system does not enter Alarm mode during the Entry Delay period setting If the delay has transpired and the system still has not been disarmed the system enters Alarm mode During Entry Delay the system signals warning beeps at two rates slower rate and faster rate during the last 10 seconds of the delay period The Entry Delay period can be between 3 to 99 seconds and its default value is 45 seconds 4 9 2 Exit Delay Exit delay allows the user a grace period for the time it takes to reach the door from the control panel when arming the system upon exit When arming a panel the system ignores zone violations during the Exit Delay period Once the delay has transpired the system enters armed mode The system may be disarmed during the Exit Delay period During Exit Delay the system signals the internal sounder 2 to sound warning beeps at two rates slower rate and faster rate during the last 10 seconds of the delay period The Exit Delay period can be between 3
3. Co a ON T VRheinland 3 HA CERT H Du e E EN ISO 13485 RoHS i S ISO 9001 A T VRheinland ISO 14001 COMPLIANT CE 0706 0960347 01
4. 5 sequential wrong code entries the system ignores further attempts for 30 seconds before accepting a new code entry Once armed the system behaves as follows 4 5 The system ignores arming commands except Disarm The system sends error indication signals if zones are either not ready or not bypassed assuming that a bypass or forced options are not enabled The system exits the Alarm mode if the alarm was caused by an alarm or tamper alarm while the system was disarmed The system enters Alarm mode if zones are violated during entry and exit delay periods unless the walkthrough feature is enabled and the violated zones are defined as walkthrough path Arming Disarming the L 2 from the System Panel The L 2 system allows you to perform arming and disarming functions directly from the system panel 16 The L 2 model features a key switch for arming and disarming the system Figure 2 L 2 Control Panel The two operational modes are triggered from the key switch as follows left to right Disarmed turn the key to the middle position AuraSys L 2 User Guide Using the AuraSvs L 2 Security System SECURITY PRODUCTS Arm Away turn the key to the right position TheL 2K model features a keypad from which you can arm and disarm the system Figure 3 L 2K Control Panel Aurasys ac amp zo 4 3 3 4 3 a SZ mess The compact onboard keypad allows you to enter a user code Enter follo
5. to 99 seconds and its default value is 60 seconds 4 10 Entering the Duress Code The AuraSys L 2K system provides a duress code function that is used to disarm the system when it is under threat The specific and unique code is defined during installation and given to the user to memorize Once entered the system immediately reports a duress situation Contact ID without entering the alarm mode or activating the sounder and outputs The silent alarm generated acts as an Ambush to report that the user is being forced to disarm the system When the system receives a Duress alarm it sends a Duress Alarm report to the central station and to private phone numbers as defined however no alarm is sounded 18 AuraSvs M L 2 User Guide Prog rammi ng Worksheets SECURITT PRODUCTS A Programming Worksheets There are several programming worksheets in this chapter so the user can set out functional requirements for the Installer Use these worksheets to create an accurate record of what is done during installation and initial programming A 1 Customer Information Customer Address Telephone Installation Date A 2 Installer Information Name Address Telephone Installers Code A 3 Device Information Module Description Location AuraSvs M L 2 User Guide 19 Programming Worksheets A 4 Zone Worksheet Zonet Input Partition PGM Crossing Type Paired Zone 01 02 03 04 20 Response Time in100ms Chim
6. Aurasvs M L 2 2 4 Zone Alarm Access Panel User Manual Models L 2 L 2K IROSSUN R SELURHI T PRODUC TS Copyright 2012 by Rosslare All rights reserved This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and or its related companies and or subsidiaries hereafter ROSSLARE Only ROSSLARE and its customers have the right to use the information No part of this manual may be re produced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of ROSSLARE ROSSLARE owns patents and patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give that party or any third party any license to these patents trademarks copyrights or other intellectual property rights except as expressly provided in any written agreement of ROSSLARE ROSSLARE reserves the right to revise and change this document at any time without being obliged to announce such revisions or changes beforehand or after the fact Table of Content
7. aSys L 2 System 3 1 Everyday Operation The AuraSys L 2 system allows you to ensure the security of your home featuring basic Disarm and Arm Away options The system allows you to control attached sub systems and appliances such as garage doors lights heating and air conditioners via an expandable PGM output The two types of panels are 2 plastic enclosure supplied with a 2 state key switch l 2K plastic enclosure supplied with a 6 button keypad for arming and disarming The following sections describe the typical use of the L 2 system in a home application 3 2 L 2K User Functions Table 1 explains the L 2K user functions Table 1 L 2K User Functions Feature Icon Description AWAY ja Red When armed Away Disarm n Green when disarmed and ready to arm Bypass X d Orange when zone s bypassed a 3 3 Indicators Bar The AuraSys L 2 system supports a range of operational indicators that can be viewed on the panel s indicators bar AuraSys L 2 User Guide 11 Operating the AuraSvs L 2 Svstem Figure 1 L 2K Indicators Bar ALARM DUE ji r AS Table 2 describes the indicators that appear on the indicator bar Table 2 AuraSvs L 2 Indicators Bar Feature Icon Description ALARM ALARM lluminated label indicating an alarm in the System 4 red illuminated zone number indicators Zones Alarm in Memory Illuminated shape status indicators for Alarm M in Memory Trouble 7 Illumina
8. e Alarm Verification PGM Activation on Zone Violation No Activity Zone Monitor in Crossing Walk through AuraSys L 2 User Guide Limited Warrantv SECURITY PRODUCTS B Limited Warrantv The full ROSSLARE Limited Warrantv Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecuritv com Rosslare considers anv use of this product as agreement to the Warrantv Terms even if vou do not review them AuraSvs M L 2 User Guide 21 OF Asia Pacific Middle East Africa Rosslare Enterprises Ltd Kowloon Bay Hong Kong Tel 852 2795 5630 Fax 852 2795 1508 support apac rosslaresecurity com United States and Canada Rosslare Security Products Inc Southlake TX USA Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 support na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAvin Israel Tel 4972 3 938 6838 Fax 4972 3 938 6830 support eu rosslaresecurity com AuraSys L 2 Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electronics India Pvt Ltd Tel Fax 91 20 40147830 Mobile 91 9975768824 sales in rosslaresecurity com IROSSUN SECURITY PRODUCTS www rosslaresecurity com uv n
9. er Guide Table of Contents 4 10 Entering the Duress Code iss iksi a e pa uu Evo Ho Cnt ver ta aerea tue 18 A Programming Worksheets 19 A 1 Cistomer IntOrtrigllobiseustun tie tliat a attuned wim Ee Seeds ie te Pop diode 19 A2 iinstalerimrorm anton ct tees aet eto eem vte ett a da Pes 19 Peo JDewuece MTOM MAIO kenisi manae ii eut united nant nite urs 19 Apo Zone Work nee aceite pgs dots Eds tae Faser Rep LE cans 20 B Limited Warranty snnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnmn a 21 IV AuraSvs M L 2 User Guide List of Figures SECURITY PRODUCTS List of Figures Figure 1 L 2K Indicators Bar sse nnnnnnnnnnnnnnnnnnnnnnnnnnnrrnnnnnnnzzznnnnnnzzz na 12 Figure 2 L 2 Control Panel L sess neennnnnnznnzznnzzznnzzrzzzzznzztzzzznnzntrzzzznzzzzzzzzn 16 Figure 3 L 2K Control Panel secs eteer emersit te eee kniikatis me ba wear UD RM pS 17 AuraSvs M L 2 User Guide V List of Tables List of Tables Table 1 L 2K User FUNCTIONS setae te ven pride Cube ee vtri ute vu a rtv tstie pu ue EN 11 Table 2 AuraSys L 2 Indicators Bar ssssssssssssss nn nn nznna 12 Table 3 AuraSvs L 2 Audible Indicators nn nennnnnnnnnnnnnnnnn nn nn 13 vi AuraSvs M L 2 User Guide Notice and Disclaimer gne ik d Notice and Disclaimer This manual s sole purpose is to assist installers and or users in the safe and efficient installation and usage of the system and or pr
10. lete description of all installation procedures refer to the AuraSys L 2 Installation Manual 8 AuraSvs M L 2 User Guide Svstem Specifications SECURITY PRODUCTS 2 System Specifications The following tables provide electrical and mechanical specifications of the security system Electrical Characteristics Power Supply Type Linear type recommended Input Voltage 16 VAC with 20 VA transformer 14 18 VAC 50 60 Hz range 24 VDC 1A 20 to 30 VDC range Input Current Standby 90 mA Maximum 258 mA Battery BT 05 Type SLA Sealed Lead Acid Voltage 12 V Capacity 800 mAh Battery BT 16 Type NiMH Nickel Metal Hydride Voltage 12 V Capacity 2 Ah RISK OF FIRE EXPLOSION AND BURNING e f replaced by incorrect battery type e Do not disassemble expose to excessive heat or incinerate e Dispose used batteries in appropriate container Environmental Characteristics Operating Environment Indoor use only Operating Temperature Range 15 C to 44 C 5 F to 111 2 F Operating Humidity Range 0 to 95 non condensing RFI Protection gt 20 V m up to 1000 MHz Supervision Tamper proof system with constant supervision AuraSys L 2 User Guide 9 Svstem Specifications Mechanical Specifications Dimensions 130x 170x 38 mm Height x Width x Depth 5 1 x 6 7 x 1 5 in Weight 250 g 8 8 oz without batterv 10 AuraSvs M L 2 User Guide Operating the AuraSvs L 2 Svstem SECURITY PRODUCTS 3 Operating the Aur
11. ned at setup A Calls central station for reporting Performs other reporting private phone Activates sounder Activates PGM output as defined The system enters Alarm mode for any intrusion burglary related event that persists longer than 400 ms The system enters Trouble mode for any fault event that persists longer than 10 seconds The system is considered as armed during entry and exit delay and behaves accordingly except in the case of a walkthrough 4 3 Alarm Mode Disarmed When disarmed the AuraSys L 2 system enters Alarm mode for each 24 hour zone Alarms trigger only for panic emergency fire 24 hour audible and silent conditions In this state the system continuously checks zone status and holds the Ready Status parameter This parameter determines whether the system is ready to arm The system becomes Ready to Arm when zones are either closed or bypassed or force arming is enabled AuraSys L 2 User Guide 15 Using the AuraSvs L 2 Security System In all other cases the svstem status is Not Readv In the Not Readv condition the svstem is unable to arm 4 4 Arming Options When the user enters a code or kev switch command the svstem responds as follows If the code is valid and correctly entered the arming disarming operation succeeds In case of a wrong code entry the system allows you to immediately re enter the code while also signaling an error indication to the user In the case of
12. o 6 user codes can be assigned All the AuraSys L 2 control panel settings are programmed via the AuraSys gt Remote Programmer software For a detailed description of all programming functions refer to the AuraSys Remote Programmer Software Manual 3 7 Additional Codes L 2K Only The system accepts an additional code for duress This code is used for disarming the system when it is under threat However once entered the system immediately reports a duress situation Contact ID without entering the alarm mode or activating the sounder and outputs 14 AuraSys L 2 User Guide Using the AuraSvs L 2 Securitv Svstem SECURITY PRODUCTS 4 Using the AuraSys L 2 Security System This chapter describes the operating conditions for the AuraSvs L 2 system It explains to the user how to place the security system in its various operational modes 4 1 Alarm Mode The AuraSys L 2 system enters Alarm mode according to the various events and zone types defined during system setup Upon entering alarm mode the system A Reports events to the central station Reports to private telephone numbers Activates sounder Activates PGM output as programmed Uses backup secondary report options 4 2 Alarm Mode Armed When armed the system enters Alarm mode if there is a zone violation regardless of perimeter or interior type Upon entering Alarm mode or when trouble conditions occur the system performs the following actions as defi
13. oduct and or software described herein Before attempting to install and or use the system the installer and the user must read this manual and become familiar with all safety requirements and operating procedures The system must not be used for purposes other than those for which it was designed The use of the software associated with the system and or product if applicable is subject to the terms of the license provided as part of the purchase documents ROSSLARE exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document This manual describes the maximum configuration of the system with the maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained in the manual are for the purpose of illustration and reference only All data contained herein subject to change without prior notice In no event shall manufacturer be liable for any special direct indirect incidental consequential exemplary or punitive damages including without limitation any and all damages from b
14. s eae ee ee 1 1 1 1 2 2 3 31 3 2 3 3 3 4 3 5 Bios BA 3 6 3 6 1 3 7 4 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 9 1 4 9 2 Table of Contents letdgerolU a Ulo a nna System Features Le seen nnnnnn nn nn na ntrama ni naninnEnnnEnantrnEnanEnanznnnE nani SVS CCM INS tl EID asciende hidumie bia idc pi depot UR Reid umet ran i haic d fun System Specifications eere eres Operating the AuraSys L 2 System mcs Ca Ol e g o C ESSEN dui ie Jare jfe ue 1s c RPM HECHOS ANE ej Ii Operational Modes a a i e a Disarmed Mode rrr rrr Ea teres s rok kk ees sedare REEERE EEEE EE L gale Armed VIG isa ita eee cnet ie i eaters del te e cot mt da User es mRRR AREEEEMM Additional Codes L 2K Only ccecccccessecceeteusseceeteeeeseeteaeeeseetens Using the AuraSys L 2 Security System Alam MOde UN REDE NM AA A NEETER Alarmi Mode AMOO i cm Alarm Mode DISA O ucc oasi tielet iiiboe biti tag rnc iin iini eani ANO OPON S EE u Arming Disarming the L 2 from the System Panel Forced ATMINQ REEL B ea TOSS qoe donc ieducsiuiast und ensust er iusta dnm atetedu hue ud pie id de Entry Exit Delay OPTIONS a xtA RO US adaa aS Enua e CT Q dl B Hn AuraSys L 2 Us
15. ted shape trouble indicator a Low Batterv a Illuminated shape low battery indicator ID Power SD Illuminated shape power fail indicator Communication n Illuminated shape indicating communication 2d failure 12 AuraSvs M L 2 User Guide Operating the AuraSvs L 2 Svstem SECURITY PRODUCTS 3 4 Audible Indicators The AuraSvs L 2 svstem sounds a range of audible indicators that notifv the user of programming or status changes in the svstem Table 3 describes the audible indicators Table 3 AuraSvs L 2 Audible Indicators Audible Description Indicator Kev Beeps Any key press generates a short 150 ms beep Approval Beeps Keypad valid entry approval is indicated by a sequence of four short beeps Wrong Beeps Invalid or wrong entries are indicated by a single long beep Warning Beeps In case of a general warning condition the system sounds 2 short beeps every 1 second Error Beep In case of an error condition due to a wrong entry or system rejection of a command or request the system sounds a continuous beep of 1 second Trouble Beeps If enabled the system sounds trouble beeps on a trouble condition Trouble beeps are a sequence of 3 short beeps repeating Chime Beeps The system buzzer emits 3 chime sounds configured by the installer 3 5 Operational Modes There are two operational modes that are controlled from the L 2 panel Disarmed mode A Armed mode The two modes are described in detail below
16. usiness interruption loss of profits or revenue cost of capital or loss of use of any property or capital or injury All graphics in this manual are for reference only some deviation between the image s and the actual product may occur All wiring diagrams are intended for reference only the photograph or graphic of the PCB s are intended for clearer illustration and understanding of the product and may differ from the actual PCB s AuraSvs M L 2 User Guide VII Introduction 1 Introduction The AuraSys L 2 2 4 zone security system manufactured by Rosslare is a compact and advanced zone hardwired control panel for residential and light commercial intrusion alarms 1 1 System Features General Attributes Onboard dual EOL zone inputs tamper 2 detection Tamper Protection Back and Front Cover Zone doubling Yes Max supported zones 4 Onboard PGM output 1 x OC 120 mA Sounder output 1x 1 Ampere Onboard AUX output 12 VDC 1 0 Ampere User codes 6 in L 2K Nonvolatile event log size 256 Central station accounts Yes primary secondary backup Private telephone numbers Yes 3 For additional details refer to Chapter 2 1 2 System Installation To ensure proper installation of the AuraSys L 2 system use skilled technicians only who must be familiar with the following General electrical installation procedures System specific post installation setup Your specific security requirements For a comp
17. wed by the code to arm disarm the system 4 6 Forced Arming If Forced Arming is enabled the system is able to arm when zones are in violation open but not defined as bypassed In such a case the system treats zones of this type automatically as bypassed zones for the arming period These bypassed definitions expire either upon disarming or once the zones are closed or supervised again during the arming period Depending on how the feature is defined during setup a report is sent to the central station This option is disabled by default 4 7 Disarming Process Users can disarm an armed system by entering their code Disarming causes the system to behave as follows Disarming a system both disarms it and stops an alarm condition Upon receiving a disarm request from the keypad the system allows up to 45 seconds for an authorized disarm code entry If it fails to receive a disarm code in this period the system enters Alarm mode When an alarm condition occurs during the disarming process the system triggers a full alarm The alarm stops on next disarming operation 4 8 Siren The siren is activated upon alarm emergency or violation of a 24 hour zone The siren timeout is set by the installer and turns off upon disarm command The siren also features momentary pulses squawk for the following events that can be enabled according to the requirements AuraSvs M L 2 User Guide 17 Using the AuraSvs L 2 Security System