Home
USER manual
Contents
1. DMX can digitally transfer data for 512 channels Choosing channels is being done by setting the base address on DIP switch according the table DIP8 DIP7 DIP6 DIP5 DIP4 DIP3 CHANNEL Proctor 1 CCN M a 1 8 Projector 2 N a 9 16 Projector 3 rr ee 17 24 Projector O a S S S 25 32 Projector 5 SN e 33 40 Projector 6 vie m _ 41 48 OFF Projector 7 Cy A a 49 56 Projecto 8 a a a 57 64 Projector 9 rr e _ 65 72 j n Projector 10 Gy e 73 80 Projector 11 Cy m a 81 88 Projector 12 a S g 89 96 Project t Noo id iii r a a dai aa aides A a a desdei at 97 512 Functions of the control channels Channel 1 Moving of the mirror horizontally X PAN Channel 2 Moving of the mirror vertically Y TILT Channel 3 Colour change Channel 4 Gobo change rotating and static Channel 5 Rotating Channel 6 Change background gobo zoom Channel 7 Dimmer Strobo effect Reset Channel 8 Prism and Special effects Channel 1 Moving the mirror horizontally X PAN Range 0 255 adjusts mirror position horizontally Values 0 and 255 adjust the mirror in one of the end position Value 128 adjusts optical centre Switching DIP switch no 1 PAN in opposite position causes that the end positions will exchange if 0 is right after switching it will be left
2. replacing the lamp or dismantling the housing Not keeping this procedure you can suffer dangerous electric shock Unplug mains lead before opening the housing and cleaning internal parts of device optical system dichroic filters etc You can suffer electric shock Description of the device 1 Detent screw Bracket screw Upper cover Objective Mirror Detent objective DMX OUTPUT XLR connector DMX INPUT XLR connector DMX INPUT Jack 6 35 connector OOMONDOABRWNY 10 DMX OUTPUT Jack 6 35 connector 11 DIP switch 12 LED indication condition 13 Fastening screw 14 Feet of device 15 Power cord 16 Fuse Unpacking Unpack the device and after acclimatisation take off the protective foil Make sure that there are no damages caused by transportation Installation The device can be installed in any position without alerting its operation For mounting use bracket of device which is a mounting hole in First make sure that the structure you are going to attach the projector is secure When installing the projector over the ground use the safe chain and steel wire rope as a double protection against falling down Make sure the housing is closed firmly with the screw tightened up It is necessary to ensure cooling fans against their covering and secure ventilator and cooling fans to have admission of air Before removal of the cover you must be sure that device is switched off Otherwise you risk damaging electronic control of
3. Optic system Parabolic mirror 2x aspheric condenser Double objective with balancing corrective fail Gobo Colours effects 4 static gobos 3rotary gobos 1 rotary dichro gobo 2 static dichro gobo 2 multicolour gobos 3 alternative intensity Frostfilter 4 multiple prisms 5 multiple prisms 3 multiple prisms 8 dichro colour light bar for blackout position steady setting dimmer strobo effect with frequency 1 7 flash per second Rainbow effect Motors 8 steps motors controlled by processor Electronic Functions ofthe device adjusts by microprocessor Output and input controlling signal in DMX 512 protocol 8 DMX channels Your distributor Mercury RotoScan DMX512 USER MANUAL 225 Dichro Gobo 2 Convertible Channel7 Dimmer Strobo effect Reset 0 lris closed 1 129 Linear Dimmer beam suppression 130 140 Iris open 141 150 Iris closed 151 240 Stroboscope effect adjusting 1 7 flash 241 245 Iris open 246 248 Reset 246 247 248 247 249 255 Iris open Channel 8 Special effects 0 47 full circle 50 49 Prism 4 100 149 Frost filter 150 199 Prism 200 249 full circle 250 255 Prism 5 Disconnect the device from the mains before any maintenance work To secure no failure operation and long lifetime it is essential to clean the device regularly Dust with smoke from fog machines air moisture and cigarette smoke is being built up on the body of the device but mainly on optical system obj
4. ective Dust penetrates through the ventilator inside of the device and settles on internal optical system consequently the light output is reduced radically Because there is a bigger danger of failure it is necessary to maintain regularly Follow these rules for cleaning Objective requires cleaning weekly by soft cloth moistened in weak soapy solution Internal parts like optical system gobo dichroic filters clean by soft brush The interior of the projector should be cleaned monthly using a vacuum cleaner Adapt cleaning interval to density of operating time NEVER use for cleaning any solvents and similar chemicals grinding sponge for dishwashing washing powder or cleaning agents with grinding effect Always replace the lamp by consistent with used type or its equivalent look chapter Installation Technical specification Supply voltage 230V 50Hz Power consumption 650W Fuse T5A Light source discharge HMI 575 GS Socket cap SFc10 Lamp life 50 300h Weight 28 Kg Dimensions 765x300x1850 Temperature 6000 K Channel 2 Moving the mirror vertically Y TILT adjust the mirror in one of the end position Value 128 adjusts Range 0 255 adjusts mirror position vertically Values O and 255 f optical centre Switching DIP switch no 1 PAN in opposite position causes that the end positions will exchange if 0 is right after switching it will be
5. faulty operating The device is supplied from manufacturer without light power Procedure 1 Loose fastening screw 2 Pulloutthe upper cover 3 If youreplace the lamp first take out original one you used before 4 Insert new lamp into the socket Never touch the glass bulb discharge lamp bare handed always use bulb cover or dry cotton cloth or gloves 5 Makesure that the lamp is installed tightly it must be in vertical direction 6 Close the cover and tighten fastening screw NEVER try lamp without cover Otherwise you risk damaging your sight by light Connection to the mains The device must always be connected behind the main switch Connection tothe control signal Each function of device is addressed according to standard protocol DMX 512 1990 4 ms It means we can control this device by any other device which provides signal included in protocol DMX 512 by serial line Connection is secured provided by screened double line ended by connector JACK 6 35 1 4 or connector XLR CAUTION In case of device has XLR connector last scaner has to be ended by 120 resistor switch between Data and Data Connection XLR and Jack 6 35 is parallel Function of the device Function of the device are controlled by 8 DMX channels Addressing you make by switch on DIP SWITCH on top of the device function DMX address PAN reversion X TILT reversion Y DIP switch no Yue 7 on1 2345678 1 Device addressing Control signal
6. left Channel 3 Colour change Range 0 127 adjusts one of colours 0 white 16 blue 32 red 48 green 64 purple 80 turquoise 96 yellow 112 lilac 127 white 128 255 Rainbow effect linear change of colours Raising value causes acceleration change Channel 4 Change gobo rotary and static 0 31 full circle 32 63 Rotary Dichro Gobo 4 64 95 Static Gobo 1 96 127 Rotary Gobo 2 128 159 Static Gobo 2 160 191 Rotary Gobo 3 192 223 Static Gobo 3 224 255 Rotary Gobo 4 All gobos is possible to change Channel 5 Rotary 0 stop without rotary 1 127 Set angle of gobos position 128 190 Rotary retrograde hour hands with deceleration value 128 is max speed 191 192 Stop without rotary 193 255 Rotary retrograde hour hands with acceleration value 255 is max speed Channel6 Change background gobo zoom APN 0 full circle eae 33 60 beam e 65 10 beam 97 Multicolour Gobo 1 129 Gobo 2 161 Multicolour Gobo 2 A 193 Dichro Gobo 1 Convertible Location Don t install the device at places with mechanical shakings and vibrations high dustiness or high temperature Not keeping these conditions can lead to shorter lifetime or its damage DON T expose the device to influence of water rain or moisture It could lead to electric shock or fire Ventilation It is necessary to ensure fans against their covering and secure the devices to have admission of air SUPPLY voltage Don t use any other supply vol
7. tage meant in technical specification and manufacture label Not keeping proper supply voltage could lead to damaging the device starting a fire or its wrong function Power cord Check if power cord is not mechanical damaged and if it is connected properly Check also if the socket is designed sufficiently for needed loading Otherwise there is a danger of electric shock or a fire Power cord must not be bent excessively led through sharp edges or given to mechanical stress Don t pull the supply lead out by the flex but only by the plug The device must always be connected behind the main switch Do not touch the supply lead with vet hands you are threatened by electric shock Other important cautions Don t poke any objects into cooling fans and ventilator it could lead to serious electric shock or damaging the device Be careful of no water or other liquid entering Maintenance and cleaning Don t use any solvent and similar chemicals which could damage surface finish or some parts of device Use soft and smooth cloth for cleaning optical parts of device and its surface Never use washing powders or other cleaning agents with grinding effect Connect the device to power supply after complete drying Service Never try to repair dismantle or do some construction changes in case of any failure Always consult qualified employee or dealer Not keeping this rule you can suffer dangerous electric shock Disconnect the device from mains before