1. 524 OUT 4 20MA OPTION 8 5 2 5 LOAD PRESET OPTION nara tn a 9 5 2 6 24H SERVICE OPTION ln i iina nn nr nt nn tra tratta 9 5 2 7 REMOTE CONTROL OPTION les nnnnnn anna nr nn r rat nn 9 5 2 8 ANTI COLLISION PROTECTION 9 5 2 9 HEAT PROTECTION OPTION ennenennnnnnnnnn mnn rna n nn nn nn t ata 10 6 MAINTENANCE rrii a a a a a a eia 11 6 1 CLEANING i ae Aas oie ead a i in nev ele 11 6 2 TROUBLESHOO TING ifa bg 11 6 3 BATTERY CHARGING 12 6 4 BATTERY CHARGING INSTRUCTIONS IN 24H 12 6 5 BATTERIES REPLACEMENT lee eeeceeceeceeeeeeeneeeneeseaeeeaeeeaeesaaesaaeseaeseaeseeeseaeeeeeeeeses 12 6 6 CALIBRATION s sa ii i e sp e deez 12 dias USER MANUAL 1 INTRODUCTION The Hanito weighing units have been designed exclusively for electronic weighing of loads on crane devices Any other use is considered inappropriate Proper usage includes adhering to all instructions contained in the operating instructions as well as performing all necessary inspection or maintenance tasks This device has been developed using the last electronics technology The steel frame is highly resistant and can support the most extremely conditions that
2. Display LCD display digits of 25mm Power supply by Rechargeable battery long use Max temperature 10 C to 50 C Frame painted Empty battery Yes Operating states indicated Tare Yes Overweight Yes Sound pressure level lt 70 dB A Weight ratio and fractions on the devices are the following However we can manufacture devices with specifications required by a customer 5 000 Kg 2 Kg 6 300 Kg 2 Kg 10 000 Kg 5 Kg 3 200 Kg 1 Kg 4 1 LOAD CELL Our load cells provide a signal 2mV V in a range of 3 000 divisions Itowa 5 INSTRUCTIONS OF USE 5 1 1 STARTING AND DISCONNECTION THE DEVICE To switch on the device you have to assembly the hoop the shackles and the hook See the picture Before to switch on the device disconnect the connector from the base of charge if it is connected Hang the device from the hoop to the hook of hoist or to any other raising element To switch on the device press the On Off button on the front panel On the display will appear the board version and after starts the auto test will appear a sequence of numbers from 0 to 9 in all the digits It is to assure that all the digits and their segments are working perfectly Once finished the sequence of Auto Test will appear 0 in the display and we can start to use the device To switch off press the On Off button during various seconds In case that after start the device appears the wo
3. for proper seating of all cotter pins If the worker that controls the weighing unit detects any visible defects he must remove them immediately If this is not part of his tasks or he is not sufficiently qualified if required he must switch off the device and notify the employer of the defect llowa 13 USER MANUAL 3 DESCRIPTION THE DEVICE 3 1 MATERIALS INCLUDED Set of materials supplied with weighing unit HANITO are the following a double protection cell of weighing an upper pivot a lower pivot a battery and a display unit and electronic weight measurement Remote functions and data transmission from the weighing device are done through an infrared system or via radio Depending on the use the device has different capabilities expressed in Kilograms or Tones 5 000 Kg 2 Kg 6 300 Kg 2 Kg 10 000 Kg 5 Kg The weighing unit is supplied in a carton box perfectly protected for its transport With the 3 200 Kg 1 Kg following 1 electronic device 2 shackles e 1 swivel hook e 1 ring 1 battery charger 1 remote control option e User Manual CD or paper CE Declaration of Conformity e Guarantee Check that your parcel contains all the mentioned elements and check material has not been damaged by the transport if required please contact SINDITO or your usual supplier Itowa media 4 TECHNICAL DATA Capabilitv From 300 to 10 000 Kg Accuracv 0 05
4. HANITO 13 ELECTRONIC DVNAMOMETER SINDITO S L IT IS FORBIDDEN TO FULLV OR PARTIALLV REPRODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM SINDITO IN THE EVENT OF INFRINGEMENT SINDITO RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARV IN ACCORDANCE WITH CURRENT LAW SINDITO RESERVES THE RIGHT TO MODIFV THIS MANUAL WITHOUT PRIOR NOTIFICATION MAH13ES REV 2 02 12 13 llowa 13 USER MANUAL TABLE OF CONTENTS TINT RODUGTION a a a 1 1 1 DIRECTIVES AND STANDARDS 1 2 SAFETY INSTRUCTIONS a 2 3 DESGRIPTION OF THE DEVIGE sepon piita b a It l 3 3 71 SSUPPLIED MATERIAL S i sta i a eine idea 3 4 TEGHNIGALIDAT A ii e b A ete ae te aed 5 4 1 LOAD CEL L iii L ae ce 4 5 INSTRUCTIONS OF USE ia d 5 5 1 1 STARTING amp DISCONNECTION THE DEVICE 5 5 1 2 FRONT PANEL BUTTONS amp 5 5 1 3 FRONT PANEL BUTTONS FOR DEVICES WITH PRINTER eee 6 5 1 4 MESSAGES ON THE 6 5 2 OPTIONS B qa Ba l 7 52 1 2 DISPLAY OPTIONS rara aeara ia 7 5 2 2 MAXIMUM PEAK OPTION Le nnennnn mnn rna nn nr tran nn 7 5 2 3 RS 232 OPTION iii i a 7
5. With this option we can get a proportional 4 20 mA output signal to the weight that means with the weight at 0 Kg we get 4mA and with the device at the maximum deep of the scale we get 20mA The connections of the connector Sub D of 9 pins that get out from our device are the following Output 4 20 mA connector Sub D of 9 pins Pin 1 Output Pin 5 Output Salida 4 20 mA del conector Sub D de 9 pines Pin 1 Salida Pin 5 Salida USER MANUAL 5 2 5 LOAD PRESET OPTION The preset of load is useful for different applications For example to limit the load that can be raised by our crane or to mix parts or to count pieces The relay output of our devices have a switch contact that can support up to 10A current at 250Vac of nominal current Default we can supply devices with 3 presets of charge depending on the system needs 5 2 6 24H SERVICE OPTION It is to get 2 interchangeable batteries to get the device working the whole day 5 2 7 REMOTE CONTROL OPTION The function of the remote controls is to make operations without using the buttons on the front panel of the device to work comfortably We have available 2 types of remote controls one way or bidirectional The one way only send signals We can supply them working through infrared or via radio the use of one or other depends on the working environment Generally the remote control via radio can be used in all kind of working e
6. bish Please follow the instructions given by the battery manufacturer concerning battery disposal To charge the batteries in the device use only the manufacturer s charging unit for the module please see accessories If a different charger unit is used the device could be damaged and its operating safety adversely affected Avoid constant high air humidity and condensation Protect the device against water spray and chemicals Fully satisfactory operation can only be ensured when the following operating conditions are met Air humidity 90 without condensation Ambient temperature 10 C 50 C Never perform any repairs on the electrical mechanical system of the devices yourself The device must be repaired only by a technical support service authorized by SINDITO S L The manufacturer accepts no liability for any damages arising from nonobservance of the cautions concerning risk contained herein The weighing system operator should not start any load motion until he makes sure that the load has been safely fastened and no one is in the risk area Before every load motion the weighing system operator must make sure that the rated load of the weakest elements of the entire load fastening system load housing elements fasteners carrier elements has not been exceeded The weighing units must be checked before each use to assure a proper union of all individual parts shackle load hooks particularly
7. en calibrated at works and no recalibration is required To ensure the precision of the equipment however it can be recalibrated every two years This calibration must be performed by a SINDITO technician Only this technician is allowed to remove the dynamometer seal and reseal the calibration 12
8. m of Maximum Peak press the button TARA continuously till appears on the screen noPIC and then the weighty will be the normal one If you want to get again the Maximum Peak please repeat the points before detailed 5 2 3 RS 232 OPTION The RS 232 option is to communicate different devices when the distance is not more than 15 meters lt 13 USER MANUAL This function is used when the device is connected to a PC to register the data of each weighty We have a protocol of communications that is the following Communications protocol Speed of transmission 1200 Bauds Data 8 Bits Starting Bits 1 Bit Stop Bits 2 Bit The sequence of transmission is the following 8 bits consecutives Start Byte 2 STX Sign Byte 43 45 Tens thousand Byte Value in ASCII Units thousand Byte Value in ASCII Hundreds Byte Value in ASCII Tens Byte Value in ASCII Units Byte Value in ASCII Finishing Byte 3 EXT Codes CODE 0 Weighty in REAL time CODE 1 Means that a TARE has been done CODE 5 Transmission of stable weighty e The connections of the connector Sub D of 9 pins that are out on our device are the following Pin 3 Output data Pin 5 GND Note The data transmission to the Pc or computer is done through the button SEND when you have a remote control or through an additional button in the front cover 5 2 4 4 20 mA OUTPUT OPTION
9. n this manual must be repaired by a technical support body authorized by SINDITO S L 11 llowa HANITO 13 USER MANUAL 6 3 BATTERY CHARGING INSTRUCTIONS e These devices have a rechargeable battery with an autonomy of 80 hours more or less depending on the weight conditions It is necessary to recharge completely the battery minimum 8 hours when on the display appears the word BATER You must charge the battery through the adapter of porter supplied by the manufacturer Please before to do check the voltage is the required by the charger We recommend do not leave to exhaust the battery to prolong the battery use 6 4 BATTERY CHARGING INSTRUCTIONS IN 24H SERVICE The devices on service for 24h we need and additional pack of batteries in order to replace the other pack previously charged in order to get always one pack of batteries charged available to use In case the device is not in use for long time is better to remove the batteries out and store the batteries charged for getting a long life performance 6 5 BATTERIES REPLACEMENT When the time of use of the batteries duly charged is decreasing substantially you will have to replace the batteries for a new pack of them using the supplied by the manufacturer NOTE To Project the environment don t forget to leave the old batteries in the points of recycle 6 6 CALIBRATION The dynamometer you have purchased has be
10. normally have the industries or the building sector where the Hanito is used This is a carefully designed high tech product which will enable you to handle your weighing problems for many years if you handle the unit properly We strongly recommend that you read the instructions carefully for precise information on the features and operating principles of this standalone weighing system 1 1 DIRECTIVES AND STANDARDS CE directives of reference 2009 23 EC Non automatic weighing instruments 2004 108 EC Electromagnetic compatibility 2006 95 EC Low Voltage 2006 42 EC Machines 1999 5 EC Radio equipment only version with radio module 2002 95 EC 2003 1 18 EC 2002 96 EC RoHS and WEEE Other Standards or documents of reference e FEM1 001 CEI EN 61000 6 2 2006 CEI EN 61000 6 4 2007 CEI EN 61326 1 2007 CEI EN 55011 2009 1999 519 EC recommendation only version with radio module ETSI EN 301489 3 1 4 1 version only version with radio module ETSI EN 300220 2 2 1 1 version only version with radio module Itowa 2 SAFETY INSTRUCTIONS This section contains some tips on safe operation of Hanito series devices 1 10 1 Only battery types approved by the manufacturer should be used If batteries from other sources are used personal injury or damage to the device may occur Batteries must be treated as hazardous waste Used batteries should not be mixed in with normal household rub
11. nvironment The remote controls by infrared only can be used in working environments where the sunlight is not entering directly to the devices The basic configurations of these remote controls are the following Note The functions of these remote controls are detailed in the section Front panel buttons amp indicators in spite that the functions can be different depending on the customers request 5 2 8 ANTI COLLISION PROTECTION OPTION All the range of products have the anti collision option being protected the device from shocks and minimizing the damage of the device llowa 13 USER MANUAL 5 2 9 HEAT PROTECTION OPTION HANITO family can be supplied with a heat protection optional to protect the device from higher temperatures in hard working environments as foundries etc Avoid the use of the device during long time in these hard working environment conditions due they can damage severely the device 10 HANITO 13 USER MANUAL 6 MAINTENANCE Except for replacing or recharging the batteries the HANITO dynamometer requires no maintenance care 6 1 CLEANING To clean the dynamometer never use grinding systems solvents or wax compounds as these products could damage the finish If an in depth cleaning is required use a cotton cloth moistened with soapy water and wipe the dynamometer carefully then clean the device with the cloth 6 2 TROUBLESHOOTING The rob
12. rd CARGA you have to press TARA That means we have started the device with some kind of weight or any element of the raising system in suspension cargo sling chains etc Be aware about the raising system of a charge cargo sling chains etc at the moment to make a weighing in order to have a correct weight we have to measure the device with the raising system in suspension There are other indirect ways to get the real weight of the charge but the described one is the most usual 5 1 2 FRONT PANEL BUTTONS amp INDICATORS The functions of the buttons are the following ON OFF Switch on amp switch off the device TARA Put the display at zero Itowa 5 1 3 FRONT PANEL BUTTONS FOR DEVICES WITH A PRINTER The functions of the buttons are the following ON OFF Start and switch off the device TARA Put the display at zero M SUMA Sum up the weight and memorize it RM TOTAL Displays the sum up of all the partial weights done M 0 BORRA The display flash the weight during some seconds and after the total weight accumulated and the partials weights erased How to make a sum up of multiples weights Every time that we make a weighty we press the M button to get it in the memory Do the same on each weighty When we have finished press the RM button and the display will show the TOTAL WEIGHT accumulated If we want to do sum up and continuous that means accumulate the following weighty to the to
13. tal weight showed press again M or SUMA The registered value will be accumulated to the previous total In every moment pressing the RM TOTAL button the display will show the accumulated value of the weighty done Note In some specific cases the meaning of the buttons can be different from the described On these cases we will send a specific manual 5 1 4 MESSAGES ON THE DISPLAY The Basic messages that appears are the following ALTO CARGA Appears when the device have a overcharge BAJO Appears when the device have a negative overcharge OFF Appears when we press the button to Switch off the device BATER Flashing when detects the battery is low After some seconds the device will get switch off HECHA The calibration is complete TARA The tare of the device is being done For other devices with especial functions there are other type of messages SUMA Means that the current weight is accumulated in the memory that have the record of the previous weights TOTAL Means that the total of all the weights has been finished and shows the result BORRA Means that will erase the total of weights and the partial weights Itowa ERROR When you try to accumulate a measure without changing the weight or you try to accumulate a value too low When you press SUMA to add the value of weighty and the charge weighty is not stabilized In this case stabilize the weight and press again SUMA ALTO Appears when
14. the total sum up of the weights exceed the numerical limit that can appear on the display vg 99999 or if you try to memorize negative quantities When you are making the calibration the messages are the following CERO You have put the zero on the converter BAJA The signal delivered by the cell is too low and can not be calibrated ALTA The signal delivered by the cell is too high and can not be calibrated CALIB The calibration is being done at this moment HECHA The calibration finished completely 5 2 OPTIONS 5 2 1 DISPLAY OPCTIONS We have 2 basic systems of viewing the data LCD Liquid Crystal and 7 segments Display Both of them are compatibles with all our products and the use of them depends on the working environment There are different sizes depending on the customers needs 5 2 2 MAXIMUM PEAK OPTION The Maximum Peak option allows to register maximum pull produced when you are raising a charge To get it e Switch on the display till the message CERO appears Press the button TARA continuously till appear on the screen the word PICOS At this moment the device go from the normal weight to the Maximum Peak Raise the weight that we will test and will appear the data registered on the display This data will appear on the display till a new Peak replace it because is higher that the previous one or due we are leaving this function of maximum peak To leave the progra
15. ust construction and careful design of the unit ensures that breakdowns are almost impossible However should this be the case the user may repair only those related to used up or defective batteries These types of breakdowns are the most frequently found equipment faults PROBLEM CAUSE SOLUTION The hook or device are not starting BATER message appears on the display In the starting test all the digits are not switched on On Off button damaged Battery is empty Display damaged Send change to the manufacturer for a Put the battery to charge during some hours Display has to be changed for the manufacturer Alter passing the test the 0 is not appearing on the display The buttons are not working with the display switch on Some raising elements are hanging on the device before it is switch on Displaced cells for over charge Defective buttons Press Tara alter finishing the Test Send it to the manufacturer Send to the manufacturer to repair Weight incorrectly Device not adjusted or bad state of the cell Contact with the manufacturer No repeat the weight correctly Bad state of the cell Contact with the manufacturer or repair The charger Light is not switch on No current on the net Bad contact on the power Defective charger Check the current arrives Replace by a new one Replace by a new one All other faults not described i