operating instructions usa operating instructions usa
Contents
1. Measurement range exceeded 1 2 an hour after a button is pressed an acoustic signal signals switch off To extend time Hose reel warning hooter activated Set screw has not been in the store position for a long time Please note After 2 hours of continuous operation the indicator light on the pressure spindle flashes at longer intervals and after 6 hours it switches into sleep mode with memory function To reactivate turn the pressure spindle into the store position wait for about 1 2 minute and turn back into the measure position In case of unknown position of pressing screw pull rotating head mobile measurement point RENEW BATTERY The battery compartment may be opened using a coin against the head of the hand held unit The used battery must be disposed off in the regional recycling system The battery for the indicator light of the pressure spindle must be renewed after about 10 years For this completely flush out the hose turn the pressure spindle into the measure position loosen 6 screws on the reel casing do not unscrew the handles and withdraw the lower reel section upwards After changing the battery ensure that the reel casing sections click together properly again Only tighten the 6 screws with light pressure NOTES ON AFTERCARE E After level measuring always put the unit back in its case BI Always keep the unit in a clean dry plac
2. OPERATING INSTRUCTIONS LEVELING INSTRUMENT ELECTRONIC LEVEL USA Please read the Operating Instructions before using for the first time Contents 01 Applications and measuring principle 02 Working range 03 The parts and their descriptions 04 Accessories optional 05 Symbols used 06 Leveling 07 Notes on handling 08 Indications for use 09 Swaying filter in level measuring mode 10 Height calibration adjustments 11 Special displays 12 Renew battery 13 Notes on aftercare 14 Observe safety in the workplace 15 Function check 16 Malfunctions 17 Warranty repair service 18 Disposal protection of the environment 19 Ec declaration of conformity 20 Technical data APPLICATIONS AND MEASURING PRINCIPLE The primary applications are taking leveling and control measurement readings in interior construction work for other applications please consult the Indications for Use Gravimetric measuring is based on the pressure differential that builds up between the hand held unit and the fluid reservoir WORKING RANGE HORIZONTAL AND VERTICAL WORKING RANGE THE PARTS AND THEIR DESCRIPTIONS Hose reel Two handles Pressure spindle Indicator light ee Hand held unit with button and display Accessories optional ACCESSORIES OPTIONAL Consisting of holder for unit 4 prods magnetic clamp and protective cap The accessories extend the range of ve
3. asuring points Vertical alignment may be judged by eye For aligning in poor light In a dark or concealed position hold displays using and then read off To terminate holding or after 40 s LED flashing light Zero regular flashing too low slow flashing too high rapid flashing INDICATIONS FOR USE If the following indications are observed nivcomp allows rapid and reliable level checking EW First check the position of the pressure spindle see Item 5 EY Taking additional measurements for checking based on the reference level considerably improves measuring reliability Ot amp gt w AROUND OVERCAST WIND SUN THE HOUSE WEATHER Outside buildings 0 1 2 3 4 5 6 Zi 8 mm Illustration Typical measurement reading scatter within hose radius as a function of thermal conditions and relative measuring height For this reason no standard deviation is given J Lay the hose flat and do not let it sag EQN When measuring several points do not do this cumulatively risk of cumulative error but in a single level measuring operation EJ in the case of a frequently used reference level provide a permanent lay on point nail EQN When the C symbol is displayed the unit must be allowed to adjust to the ambient temperature for a few minutes e g after being in transit or at extreme temperatures Keep the outline or visual angle EMM Do not fling the hose shock D gt At low temperatures av
4. e once you have cleaned it EQ Only use solvent free cleaning agents sie e If the unit is not to be used for a long period set the pressure spindle to the store position OBSERVE SAFETY IN THE WORKPLACE A E Do not run the hose at a height off the floor trip hazard and risk of catching in vehicles BI Always top off the accessory prod extension with the protective cap E Do not use the magnetic clamp above head height FUNCTION CHECK EP Measurement reading stability temperature stabilized When placed on the reference level for several minutes the deviation should not exceed 1 B Pressurization Put the hand held unit down and save the position as the reference level Then turn the pressure spindle to the limit of the store setting The value displayed should be in the range 600 1800 MALFUNCTIONS EY Unit does not start or suddenly switches off Check battery and battery contacts EY Unit switches off with the battery symbol flashin Renew the battery EYP indicator light of the pressure spindle does not flash See also special displays Flashing is only weak Renew the battery EQ increased deviations on taking level measurement readings Have you checked the pressure spindle and C symbol Have you followed the notes on Measuring outdoors Are there airlocks in the hose or sensor area Bleeding by our technical service Air bubbles can arise if the pressure spindle has been left for several days in
5. evel conforms with the relevant basic health and safety requirements of the EC directives Relevant EC directives EC Directive on Electromagnetic Compatibility Directive 89 336 ECC 92 31 ECC EN61326 A1 A2 A8 EN61000 6 1 EN61000 6 3 A11 aft Forks Dietzsch amp Rothe MSR Technik OHG OlzmannstraBe 47 D 08060 Zwickau www dirotec com TECHNICAL DATA Measuring principle Analog with digital display Reproducibility indoors typical 2 mm At maximum measuring point distance 48 m Vertical working range 2 5 m 4 0 m Height display mm inch Resolution 1 mm prefixes 0 3 mm Approx temperature range for use 0 35 C Battery for hand held unit 1 x AA alkaline 1 5 V Power required On time 10 mW 2250h Automatic switch off 33 min after pressing a button Flashing indicator 3V Li Lifetime 10 y Shock resistance ca 1 m impact height Transport and storage 10 40 C 30 55 C Dimensions 450 x 420 x 150 mm Weight Approx 5 5 kg Certification C FE RoHS compliant Low emissions In line with EMC product standard pes TOPLEVELTOOLS INNOVATIVE PRO GRADE TOOLS WWW TOPLEVELTOOLS COM 603 570 4852 ONE NEW HAMPSHIRE AVENUE SUITE 125 PORTSMOUTH NH 0380 USA
6. oid transmitting warmth from your hands to the hose EMM On wet surfaces only measure with protective interlayer Measurements outdoors D gt Avoid intense or intermittent sunshine on unit components A good time for level measurements outdoors is the early morning gt Do not lay the hose over heated surfaces or expose to major changes in tempe rature e g on exposed outdoor wall areas SWAYING FILTER IN LEVEL MEASURING MODE Activate the swaying filter by double clicking 2x symbol When there is inter ference from swayings a more lethargic response is sometimes beneficial To deactivate filter HEIGHT CALIBRATION ADJUSTMENTS On starting the unit press the button until SEEE is displayed The setting options will now follow each other in slow sequential order After each operation press the button h 0 Correction of height display by 1 mm meter for each press of the button a i Correction of height display by 1 mm meter for each press of the button ae Direction or prefix display arrows or inch nana Height display selection in inches 88 or millimeters P Set all settings to factory settings Reset Height calibration should be checked once a year against a vertical tape measure SPECIAL DISPLAYS Battery has power in reserve for another 20 50 hours bREE Warning flashing battery discharged from 20 hours of reserve power g Critical temperature change ZII
7. r tical measurement The prods are to be fitted to the top or bottom depending on the direction of measurement and should have the magnetic clamp or protective cap attached at the end SYMBOLS USED __ Press button for a short time 2s Press button for about 2 seconds l 5s Press button for about 5 seconds 2x Double click on button Always turn pressing screw in the direction of measure until the noticeable final position Indicator light flashes position Indicator light goes OFF Acoustic signal sound LEVELING Preparing for leveling EQ Put the case or reel in a stable position B Reduce the system pressure 2 EJ Let out enough hose allowing all measuring points to be reached without tension on the hose reel Measuring Additional functions Button Display Button Display Le on 7 Start 65 sete Place against reference Settings Se point and hold steady see Item 10 Ezz aa Save the reference level 2 O Check level between measuring points gt GE Sold mmm EE Continue em B Vibration filter on oe em EP Vibration filter off B2 _ Return to start position E oF Switch off Terminating measuring mode E Reel in the hose without twisting it BI Put the unit in the case EMM Pressurize the system e NOTES ON HANDLING The selected lead edge on the reference level applies for all further me
8. the measure position as well as due to overheating or shock EN Damp or condensed water in the case If there is damp in the hand held unit it must be removed from the battery and only replaced after being dried Open the unit and the case and dry them EY Leak in the hose system The special hose can withstand high levels of mechanical stress abrasion and crushing If system fluid does leak out non poisonous and oily soak this up using suitable means and dispose of in line with the regulations relating to waste oil Repair by our technical service WARRANTY REPAIR SERVICE Distribution and service is via reputable specialist dealers Repairs are performed free of charge within the warranty period provided the defect is due to identifiable faults in material or manufacture The unit must be sent to the supplier in a clean condition A description of the fault or defect must be included Current service addresses may be found at www dirotec com DISPOSAL PROTECTION OF THE ENVIRONMENT In line with EU directive 2002 96 EC WEEE at the end of its useful life the user is obliged to return this leveling instrument to the manufacturer for waste utilization or environmentally friendly disposal by dirotec amp EC DECLARATION OF CONFORMITY We hereby declare as the exclusive responsible party that on the basis of its design and construction the nivcomp electronic hydrostatic l