Home
Spark Driver Module Kit User`s Manual
Contents
1. Drivven Inc 2009 Spark Driver Module Kit User s Manual D000012 Rev F 14 Drivven Inc Spark Driver Module Kit location Finally specify an appropriate name for the module which will later appear in the FPGA I O nodes in the FPGA block diagram Having meaningful module names is important for preventing coding mistakes 13 After adding a module to the project a folder will automatically be added to the project having the same module name given in the module configuration dialog The folder will contain the FPGA I O pins for the module slot These I O pins can be selected in the block diagram when connecting the module VI PinInput and PinOutput clusters to FPGA I O nodes The example application discussed below should be consulted for further details about connecting the PinInput and PinOutput clusters to FPGA I O nodes Within the example projects notice the FPGA I O node elements having module name prefixes 14 Some Drivven modules can be automatically recognized by LabVIEW when adding cRIO modules to the project However Drivven does not recommend using this feature because the module names which are automatically assigned are not meaningful Mod1 Mod2 etc and can lead to coding mistakes when wiring the Drivven FPGA VIs to the I O nodes Adding the modules to the project manually as described above is still the recommended method Driven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 15 Drivve
2. Module over temperature protection gt External power supply of 6 32V O O 100 0 Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 3 Drivven Inc Spark Driver Module Kit Pinout BATT SPK1 SPK2 SPK3 sSPK4 SPK5 SPK6 SPK7 SPKS 2 3 4 5 6 Li 8 9 GND Hardware The Spark Driver Module Kit provides eight inductive type ignition coil drivers in a National Instruments CompactRIO module Revision Notes Revision F of the Spark Driver Module Kit incorporates firmware and software changes that are not compatible with previous versions of the module Software for revision F will not recognize modules of previous versions Be sure to use the RevF FPGA VIs with the RevF module Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 4 Drivven Inc Spark Driver Module Kit Powering the Module The Spark Driver module requires power from two different sources One source is from the CompactRIO backplane male high density D Sub 15 pin HD15 connector which mates with the module s female HD15 connector This power source provides a regulated 5 volts and ground to various digital logic functions within the module The CompactRIO 5V source is active whenever the CompactRIO or R Series Expansion Chassis is properly powered The module should only be powered at the HD15 connector by plugging it into a CompactRIO or
3. SparkEnable booleans 4 If Dwell is modified during the main spark pulse to a value greater than the existing dwell then the pulse is continued only until EndPosition unless CutoffPosition or MAX_DWELL of 5 msec is encountered first Modifications to EndPosition EndPosition can be modified at any time However the value must not be advanced by more than 45 CAD within a single engine cycle This value is referred to as the History Window The spark VIs continually check the requested EndPosition with respect to the current crank position If the EndPosition is modified by the CPU to a position in the past the spark VIs use the History Window to determine whether a late spark pulse should be started 1 For example let s assume that a spark pulse is scheduled for an EndPosition of 200 Absolute CAD ACAD and a dwell time of 40 000 ticks 1 0 msec such that the spark pulse is scheduled to turn on at 150 ACAD Let s also assume that the CurrentPosition of the EPT VI is 140 ACAD when the CPU modifies EndPosition to 180 ACAD which means that the required start of the pulse is now 130 ACAD This new start is in the recent past by 10 CAD Since this is less than the 45 CAD History Window then the spark VI will immediately start the spark pulse even though it is late The dwell will be turned off at EndPosition as long as MinDwell is satisfied 2 As another example let s assume that a spark pulse is scheduled for an EndPosition of 200 ACAD and
4. spark_vt_8mux1_revf vi This VI is for interfacing directly with the Drivven Spark Driver module and for providing a control interface to the LabVIEW RT level Number of Spark Cores Implemented 1 2 3 4 0 Number of Channels Operated 1 2 3 4 6 or 8 The FPGA VI must be placed within a Single Cycle Loop SCL of a LabVIEW FPGA block diagram The SCL must execute at the default clock rate of 40 MHz The FPGA VI requires a pre synthesized netlist file having a matching name and an extension of ngc The netlist file must be located in the same directory as the matching VI The installer will place this file in the LabVIEW addons directory along with the FPGA VI The Pininput and PinOutput clusters are wired to LabVIEW FPGA I O nodes which are configured for acRIO controller chassis or a cCRIO R Series expansion chassis Refer to the LabVIEW FPGA documentation for details about creating and configuring FPGA I O nodes Connector Pane SparkControl FuelSparkSupervisor SparkPinInput SparkData SparkPinCiutput Controls and Indicators SparkControl This cluster contains controls for enabling and configuring the spark channels HH SparkEnableX When TRUE the spark command is enabled When FALSE default the spark command is disabled EndPositionX Spark pulses are generated with a trailing edge coinciding with EndPosition The length of the pulse will be according to Dwell The leading edge will be determined by the cur
5. R Series Expansion Chassis The module s HD15 connector should not be connected to any other device Another required power connection is at the external screw terminal connector The terminals are labeled BATT 0 and GND 9 Typical power sources will be from automotive 12V or 24V battery systems However the module can accept power from a range of 6V to 32V With no actuators connected the module requires up to 100mA from the external supply However the external supply must be capable of powering the actuators connected to the module Therefore a battery or power supply capable of 7A may be necessary under full load The external battery power ground is completely isolated within the module from the CompactRIO 5V supply ground However the external battery ground and the CompactRIO ground may be connected externally The module will not be recognized by software without both power supplies active Warning The external battery supply input terminals are not reverse voltage polarity protected Connecting power to the module in reverse polarity will damage the module This event is not covered by the warranty Please refer to the DrivvenReverseBatteryNotice pdf document available on the website for a recommended solution for protecting a system from reverse battery polarity Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 5 Drivven Inc Spark Driver Module Kit Platform Compatibility CompactRIO
6. dwell Each channel is capable of driving to a peak of 7 amps During operation a channel is turned on low side switch to ground sinking current through the primary winding of an ignition coil thus storing magnetic energy in the coil When the channel is switched off the magnetic field of the primary quickly collapses causing the voltage across the secondary winding to spike delivering a spark across the gap of a connected spark plug The spark must find a path to battery ground via ground connection with the spark plug body The engine cylinder head will provide a ground path for the threaded spark plug body and must have a ground connection back to battery The Spark Driver Module Kit is not intended to control smart ignition coils with built in driver or igniter circuits Smart coils require digital commands whereas the Drivven Spark Driver Module contains low side switches for sinking current through a standard ignition coil primary winding For commanding smart coils consider the Drivven Engine Synchronous TTL Output Module Kit The amount of time that the driver channel is turned on or dwell time will in part determine the voltage that can be achieved at the spark plug gap The gap length also determines the spark voltage The dwell time required to achieve certain spark energy will vary with the characteristics of the ignition coil For example the dwell time required to achieve 20 kvolts at the spark gap using different coils co
7. handling any of these parts Receiving an automotive ignition spark at any voltage can be very painful Persons with medical devices or heart conditions should not be involved with testing or installing ignition systems Use a current probe to monitor the current through the primary while conducting dwell tests Most passenger car ignition coils require 3 7 peak amps to achieve a consistent spark If the coil manufacturer s recommended current rating is not known then it is good to use the current probe to know if excessive current is required to achieve spark If more than 8 amps are required to achieve spark then the module will not be able to drive the coil at higher engine speeds without overheating The module is fuse protected for a total current of 10 amps Prepare an application for simulating a running engine using your EPT VI There is an example application included with the Spark Driver Module Kit for this purpose The Spark Driver Module should be powered externally from the same power supply battery voltage which feeds the high side of the ignition coil s Connect one side of the coil primary to battery voltage and be sure to use an automotive fuse 7 5A in this connection We are all prone to making mistakes with connections and software settings It is better to blow an external fuse than the fuse within the module Connect the other side low side of the coil primary to the spark driver module channel that you will be using for te
8. lookup Vis or CalVIEW table lookup Vis Do not use a fixed dwell time in your application if you expect the battery voltage to vary This could lead to weak sparks or blowing the module fuse Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F Drivven Inc Spark Driver Module Kit Ignition coil primaries should be wired to the Spark Driver Module according to Figure 3 An automotive 7 5A fuse is recommended to be used in series with the high sides of the primaries Spark Module Connector Notes 3 N N Battery or Power Supply 12V Typical gt 10A Peak OO JO UL ONO M El Spark Plug E Spark Plug Figure 3 Connecting ignition coils to the driver module Use 18AWG or larger diameter wire Spark plug body must have ground path back to battery A CompactRIO controller may be powered by the same power source or by an isolated power source If the cRIO controller is powered by the same battery and this battery is used for cranking the engine then it is possible that the battery voltage will drop below 9V during cranking causing the cRIO controller to reset This can be prevented by using a small backup battery and a diode pack for the cRIO controller Please contact Drivven for recommended parts and connections When using wasted spark ignition coils which have two secondary connections per primary Drivven recommends connecting two spark driver channels to e
9. AT per engine cycle would be 2 60 128 15360 MAX_CAT Maximum Crank Angle Ticks per engine cycle Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 16 Drivven Inc Spark Driver Module Kit Table 1 shows a list of all spark VIs included in this kit Table 1 Spark VI Configurations Number of Spark Outputs VI Name WasteSpark FALSE k spark_vt_1mux1_revx vi spark_vt_1mux2_ revx vi spark_vt_2mux1_ revx vi spark_vt_1mux4_ revx vi spark_vt_2mux2_ revx vi spark_vt_4mux1_ revx vi spark_vt_1mux6_ revx vi spark_vt_2mux3_ revx vi spark_vt_3mux2_ revx vi spark_vt_6muxl1_ revx vi spark_vt_1mux8_ revx vi spark_vt_2mux4_ revx vi spark_vt_4mux2_ revx vi CO CO Od ODI DI ODI oO JoO 2 2 2aj nDn n spark_vt_8mux1_ revx vi As can be seen from Table 1 there are multiple Vis that support two four six and eight spark driver outputs For example if an engine control system was being prototyped for an eight cylinder engine with one coil per spark plug then there are four different Vls to choose from which support eight spark outputs One of those VIs internally contains eight individual spark cores each controlling a single output Another VI internally contains four spark cores each multiplexed to control two outputs Another VI internally contains two spark cores each multiplexed to control four outputs Finally another VI contains a single spark core multiplexed to control all eight
10. DRIVVEN Spark Driver Module Kit User s Manual D000012 Rev F January 2009 Drivven CompactRIO Spark Driver Module Part DO00012 8 Ch Inductive Style ignition Coil Driver o 0 N oO ao A U N Drivven Inc 12001 Network Blvd Bldg E Suite 110 San Antonio Texas 78249 USA Phone 210 248 9308 Web www drivven com E mail info drivven com Drivven Inc Spark Driver Module Kit Contents o A A E O EEEE 3 PES ESOO EI ness A E S 4 E A O no o II A 4 A AAN PP o o A 5 Hattotia Comp alborada A 6 SPED e PPPPUO 0 ORCOOA cease cena o E A sess 7 JU AAA o e A 12 Crestino a LabVIEW PO birria 14 Subo VL DOCUMENTI O ness pios oo E EEEE 20 Spark Command Scheduling Notes sscicnccsoueivnssdazcerercteswdencandeedsevednssesaannenevassuencendendsoues este 23 Warning About FPGA I O Node Wiring ccoooooocnccnnnncncnononocnnnnnnnnononnnnnnnnnnnnnnnnnnnnnnnncnnnnnnos 24 Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 2 Drivven Inc Spark Driver Module Kit Introduction The Spark Driver Module Kit provides a CompactRIO cRIO module for driving up to eight ignition coils The kit includes LabVIEW FPGA VIs for controlling all driver channels individually controlled for timing Features gt 8 channel inductive type ignition coil driver Software configurable for dual output coils wasted spark 7A primary peak current maximum per pulse Short circuit protection Internally fuse protected at 10A
11. GA I O Method Node The Boolean indicator named IDSelectOut must be connected to a Set Output Data method of an FPGA I O Method Node The remaining Boolean indicators must be connected to their corresponding FPGA I O Node output item SparkData Provides status indicators for the spark driver module ModulePresent Indicates that the module is present in the correct slot externally powered and recognized by Drivven software ModuleOverTemp Indicates that the module has exceeded its internal temperature limit and temporarily shut down Drivven Inc 2009 Spark Driver Module Kit User s Manual D000012 Rev F 22 Drivven Inc Spark Driver Module Kit Spark Command Scheduling Notes The Spark Vis provide features that ensure the best possible spark command delivery even while the CPU makes modifications to EndPosition and Dwell asynchronously to engine position Modifications to Dwell Dwell MinDwell OffTime 1 Dwell parameters can be modified at any time 2 If Dwell is modified during the main spark pulse to a value less than the previous value of Dwell then the pulse is continued until EndPosition 3 If Dwell is modified to a value less than MinDwell 0 for example then the pulse will still be started according to the value of Dwell and engine speed but MinDwell will take precedence by sacrificing the requested EndPosition to ensure a spark occurs This scenario should be avoided Spark pulses should be disabled with the
12. a dwell time of 40 000 clock ticks 1 0 msec such that the spark pulse is scheduled to turn on at 150 ACAD Let s also assume that the CurrentPosition of the EPT VI is 140 ACAD when the CPU modifies EndPosition to 120 ACAD which means that the required start of the pulse is now 70 ACAD This new start is in the recent past by 70 CAD Since this is greater than the 45 CAD History Window the spark VI will not generate a late pulse effectively skipping a cycle without a spark pulse The following cycle will have a pulse delivered starting at 120 ACAD CutoffPosition must be set so that the following conditions are satisfied 1 Inthe case of non multiplexed spark Vis CutoffPosition must be set at least 45 CAD after EndPosition If this minimum spacing is not maintained then spark commands will be generated incorrectly Driven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 23 Drivven Inc Spark Driver Module Kit Warning About FPGA I O Node Wiring Great care should be taken to ensure that I O nodes are wired to the correct Pininput and PinOutput clusters of the correct module VI If wired incorrectly then undefined behavior or module damage could result LabVIEW FPGA does not yet provide a method for 3 party module vendors to hide the DIO pins behind module VIs and still be portable to various system configurations Therefore a double check of the I O node wiring is recommended Two LabVIEW FPGA code snippets are sh
13. ach shared primary in parallel Then use the two spark channels as if driving two independent ignition coils Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 10 Drivven Inc Spark Driver Module Kit Driver Channel Protections The spark driver channels are short circuit protected However there is no short circuit fault detection reported via software If a short circuit is present the driver channel will immediately disable itself during the dwell command Another driver attempt will be made at the next pulse The driver channels are software limited to 5 msec of dwell however this may be much too long for a given ignition coil Therefore it is important that the user perform the above described bench tests in order to fully understand the proper range of dwell time for a given ignition coil Dwell time should also be limited to approximately 25 duty cycle For example if an engine is running at 8000 RPM then the dwell time should be limited to 3 75msec If wasted spark mode is enabled or re strike pulses are enabled the dwell time must be limited even more For example if an engine is running at 8000 RPM and wasted spark mode is enabled then the dwell time should be limited to 1 875 msec If using double ended coils in wasted spark mode and dwell times are required to be greater than the maximum dwell calculated for wasted spark mode then two driver channels can be used to drive the same double ended igni
14. category ii Double click the desired target to add it to your project b New Target or Device Expand the appropriate category in the Targets and Devices list to see all possible targets within that category ii Double click the desired target to add it to your project If the new FPGA target was not currently in the system right click on the FPGA target within the project and open the properties dialog to set the resource name if necessary The resource name can be found from MAX when connected to the actual remote system 10 If the FPGA target is a PXI or PCI card then an R Series expansion chassis must be added under the FPGA target This is done by right clicking on the FPGA target and navigating to New gt R Series Expansion Chassis Within the following dialog select the appropriate FPGA connector to which the chassis will be connected A unique name for the chassis may also be specified 11 Right click on the R Series expansion chassis or cRIO FPGA target chassis and navigate to New gt C Series Modules 12 Select the New Target or Device radio button and double click on the C Series Module in the Targets and Devices list In the following dialog select the desired Drivven module at the bottom of the Module Type list The Drivven modules will be appended there if any Drivven module software has been installed Select the appropriate module 2 Di 4 J O
15. ered terminals However the contents of the SparkControl cluster will vary SparkControl FuelSparkSupervisor SparkPinInput Figure 4 Spark VI icon with leads SparkData SparkPinQutput The FPGA VI must be placed within a Single Cycle Loop SCL of a LabVIEW FPGA block diagram The SCL must execute at the default clock rate of 40 MHz Drivven Inc 2009 Spark Driver Module Kit User s Manual e DO00012 Rev F 12 Drivven Inc Spark Driver Module Kit The FPGA VI requires a pre synthesized netlist file having a matching name and an extension of ngc The netlist file must be located in the same directory as the matching VI The installer will place this file in the LabVIEW addons directory along with the FPGA VI Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 13 Drivven Inc Spark Driver Module Kit Creating a LabVIEW Project Drivven recommends working from the provided example application as a starting point for learning the use of the Drivven software blocks However the following section describes starting a LabVIEW project from scratch and adding a Drivven module 1 Install the Drivven software by running the installer executable and accepting the software license agreement Restart LabVIEW if previously running and create a new LabVIEW project Give the new project a name by clicking the Save Project button on the project toolbar Right click on the highest item in the p
16. gram Files National Instruments LabVIEW X X vi lib addons DrivvenProductRelease When working with block diagrams user s will notice a Drivven function palette added to the standard LabVIEW palette specific for the RT or FPGA target VIs for a specific Drivven product will be categorized according to product name Also some Drivven products will install RT and FPGA VIs under a General function palette which is intended to be used across multiple products Requirements The Drivven VIs require LabVIEW 8 5 Full Development or later LabVIEW RT Module 8 5 or later LabVIEW FPGA Module 8 5 or later NI RIO 2 4 or later Drivven EPT VI VVVV V The FPGA VI supplied with this kit cannot generate fuel commands without the supervision of an engine position tracking EPT VI from Drivven The EPT VI provides the necessary output cluster to be wired to the FuelSparkSupervisor input cluster The Spark Driver Module Kit is provided with 14 different LabVIEW FPGA VIs Each VI includes an interface for controlling a different number of spark channels with non multiplexed or multiplexed internal spark control cores This gives the user the ability to optimize FPGA resources depending upon maximum engine speed and dwell requirements There is also a WasteSpark control input which allows the use of dual output ignition coils for pairs of opposing cylinders Figure 4 shows the icon which represents all supplied VIs having identical clust
17. ition This is an approximate rule and should be retarded out further if engine speed fluctuations are enough that pulses are being cut short For non multiplexed Vis CutoffPosition MUST ALWAYS be at least 45 CAD after EndPosition If the minimum spacing of 45 CAD is not maintained for non multiplexed VIs then spark commands will be generated incorrectly The units of CutoffPosition are CAT Drivven provides Offset2CAT vi in the General RT VIs in the RT function palette This VI can be implemented at the LabVIEW RT level for converting CutoffPosition in CAD with respect to a cylinder TDC to CAT Dwell Determines the length of the spark command delivered to the driver circuit Dwell is entered in terms of 40 MHz clock ticks and is internally limited to 200 000 ticks 5 msec The value is also internally limited to 18 bits Values larger than 18 bits will roll over from zero Dwell uint32 ticks Dwell msec 40 000 Drivven provides time2ticks vi in the General RT VIs in the RT function palette This VI can be implemented at the LabVIEW RT level for converting time in milliseconds to 40 MHz clock ticks OffTime Determines the length of inactivity following each spark pulse It is recommended to set this value to at least 100 usec OffTime provides a minimum amount of time for the command to be off to allow the actual spark to occur before turning the coil back on OffTime is entered in terms of 40 MHz clock ticks and is internally limited
18. k tester device Using the built in simulator feature of the Engine Position Tracking VI the user can simulate a running engine and generate sparks on a test bench by connecting a test coil to a spark driver channel and a spark tester device to the coil A spark tester device is a low cost tool sold at most auto parts stores which fits into the boot of a coil or plug lead just like an ordinary spark plug The gap of the tester is adjusted by a threaded rod with a pointed tip The body of the spark tester is marked for approximate gap voltages The tester shown in Figure 2 is made by Thexton part 404 and is sold for approximately 10 USD The spring clip must be connected to battery ground to provide a ground path for the spark If the spark does not have a ground path back to battery then there will not be a spark seen at the gap Instead the ignition coil will arc within itself and could cause damage to the coil Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 7 Drivven Inc Spark Driver Module Kit Figure 2 Thexton adjustable spark tester Part 404 WARNING Automotive ignition coils can generate lethal voltages The user should be extremely careful when handling the ignition coil spark plug or spark testing device Do not touch the coil or spark tester device while performing spark tests Do not attempt to adjust the spark tester while performing spark tests Remove power to the ignition circuit before
19. le one cylinder is at top dead center compression the pairing Drivven Inc 2009 Spark Driver Module Kit User s Manual e DO00012 Rev F 21 Drivven Inc Spark Driver Module Kit cylinder is at top dead center exhaust A dual output coil will spark in both cylinders at the same time sparking into a combustible mixture in one cylinder while sparking into inert exhaust gases in the other When WasteSpark is TRUE the number of available spark channels will be divided by 2 For example in the case of using an eight channel spark VI only the first four driver channels would be used instead of all eight Pulse 1 will be paired with pulse 5 on channel 1 pulse 2 paired with pulse 6 on channel 2 pulse 3 paired with pulse 7 on channel 3 and pulse 4 paired with pulse 8 on channel 4 If using the waste spark mode and the dwell time per channel is greater than 25 duty then WasteSpark should be set to false and two spark channels should be used to drive the same coil primary FuelSparkSupervisor This cluster input must be wired directly from the FuelSparkSupervisor cluster output of a Drivven EPT VI The FuelSparkSupervisor cluster from a single EPT may be used to supervise any number of Drivven engine synchronous output sub VIs SparkPininput These Boolean controls must be connected to their corresponding FPGA I O Node input item SparkPinOutput The Boolean indicator named IDSelectEn must be connected to a Set Output Enable method of an FP
20. modules from Drivven are compatible within two different platforms from National Instruments One platform is CompactRIO consisting of a CompactRIO controller and CompactRIO chassis as shown in Figure 1a below Figure 1a CompactRIO platform compatible with Drivven CompactRIO modules The other platform is National Instruments PXI which consists of any National Instruments PXI chassis along with a PXI RT controller and PXI 78xxR R Series FPGA card An R Series expansion chassis must be connected to the PXI FPGA card via a SHC68 68 RDIO cable The CompactRIO modules insert into the R Series expansion chassis This platform is shown in Figure 1b below et T arenes Peo i oye T yr 7 NA TF e PEE 1 Figure 1b PXI platform compatible with Drivven CompactRIO modules Drivven CompactRIO modules are not compatible with the National Instruments CompactDAQ chassis Drivven CompactRIO modules REQUIRE one of the hardware support systems described above in order to function The modules may not be used by themselves and or interfaced to third party devices at the backplane HD15 connector These efforts will not be supported by Drivven or National Instruments Drivven Inc 2009 Spark Driver Module Kit User s Manual e DO00012 Rev F 6 Drivven Inc Spark Driver Module Kit Spark Drivers Each spark driver channel is capable of directly driving a single ignition coil primary and is independently controlled for timing and
21. n Inc Spark Driver Module Kit Brief Glossary of Terms CAD Crank Angle Degrees There are 360 CAD per two stroke cycle or one crankshaft rotation There are 720 CAD per 4 stroke cycle or two crankshaft rotations In a 4 stroke engine the camshaft completes exactly one rotation per two rotations of the crankshaft There are two strokes of the piston up and down within the cylinder during a single rotation of the crankshaft A single stroke of the piston covers 180 CAD EXTRAP Level of EPT Position Extrapolation This is a fixed power of two by which the angular resolution of tracked crankshaft position is improved over the physical teeth alone For example if the EPT VI has a fixed extrapolation level of 7 then the crank angle resolution between each physical tooth is improved by a factor of 2 7 128 CAT Crank Angle Ticks Single unit of angular measure reported by the CurrentPosition output of the EPT VI Reported as a power of two angular ticks of crank position travel having a resolution dependent on EXTRAP and the number of physical teeth per crankshaft rotation For example if using the N M EPT VI which has an extrapolation of 7 the number of CAT per crank tooth would be 2 7 128 and CurrentPosition would be evenly incremented by 128 CAT from one physical tooth to the next If a 60 2 pattern were used the maximum number of CAT per crankshaft rotation cycle would be 60 128 7680 If the engine was a 4 stroke the total number of C
22. outputs The VI chosen will depend upon the maximum dwell required for the ignition coil and the maximum engine speed The VI which has 8 spark cores will require more FPGA resources than the VI which has a single spark core If the non multiplexing VI spark_vt_8mux1_revx vi is chosen then it is possible for all soark outputs to overlap Ifa multiplexing VI is chosen then consideration must be given to dwell and engine speed to ensure that consecutive spark pulses generated by the same spark core will not interfere The plots in figures 5 8 show how the spark cores are multiplexed for each of the four eight channel VIs Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 17 Drivven Inc Spark Driver Module Kit SparkCore1 f 1 SS SparkCore2 Of eee SparkCore3 A EE Lo SparkCore4 A E SparkCore7 A ooo oo SparkCore8 A 8 tt 0 90 180 270 360 450 540 630 CAD Pulse numbers note the spark output channel Figure 5 spark_vt_8mux1_revx vi contains 8 non multiplexed spark cores SparkCore1 O A E SparkCore2 Of O o i y i i fab SparkCore3 O O E A A SparkCore4 OM eee E tt 0 90 180 270 360 450 540 630 CAD Pulse numbers note the spark output channel Figure 6 spark_vt_4mux2_revx vi contains 4 spark cores multiplexed into 2 outputs each SparkCore1 1 3 5 7 SparkCore2 2 4 6 8 es A AAA A A O PS A ee 0 90 180 270 360 450 540 630 CAD Pulse numbers note the spark output channel Figure 7 spark_v
23. own below from an ADCombo implementation which illustrate this issue Figure 9 shows the correct implementation of the FPGA I O node block for the PinOutput cluster of the ADCombo On the other hand figure 10 shows a coding mistake that should be avoided Notice the ADCombo output items where a Spark module output item is selected instead of the correct ADCombo module output item This means that the Spark DIO5 output is being driven by the ADCombo logic and will cause strange behavior of the spark module or possible damage IDSelectEn S im ADComba SPI Clk os ET ADComba SPI CS DIO5 E DIO F JUL ADCombo SPI MOSI DIO7 Figure 9 Representative FPGA output node for ADCombo with correct output item selection IDselectEn EA IDselectOut oP ADCombo sPrCk_ 5 DIOS r Mu Spark SPICS DIOS PIU ADCombo SPI MOSI DIO7 DIO Figure 10 Representative FPGA output node for ADCombo with incorrect output item selection for DIO5 This will cause strange behavior or damage to the spark module Applying meaningful names to the modules within the project can help identify these coding mistakes Drivven Inc 2009 Spark Driver Module Kit User s Manual D000012 Rev F 24
24. rent requested Dwell and the current engine speed EndPosition will always take precedence over Dwell in the presence of engine speed fluctuations If the engine speed increases after the spark pulse has started then the actual dwell will be slightly shorter than the requested Dwell to ensure that correct spark timing is achieved Likewise if the engine speed decreases after the spark pulse has started then the actual dwell be will slightly longer than the requested Dwell However MinDwell will take precedence over EndPosition to ensure that a spark occurs even if it is late Also a maximum dwell of 5 msec is enforced to protect the driver circuit even if the end of the spark pulse must occur before EndPosition The units of EndPosition are CAT Drivven provides Offset2CAT vi in the General RT VIs in the RT function palette This VI can be implemented at the LabVIEW RT level for converting spark advance in CAD with respect to a cylinder TDC to CAT CutoffPositionX All spark pulse activity is Cutoff at CutoffPosition and reset for the next pulse For multiplexed Vis CutoffPositon is the position at which the next consecutive spark pulse parameters will be loaded for the given internal spark core For multiplexed Vis CutoffPosition should be set to a position close Drivven Inc 2009 Spark Driver Module Kit User s Manual D000012 Rev F 20 Drivven Inc Spark Driver Module Kit to but after the most retarded spark timing pos
25. roject hierarchy Project and navigate to New gt Targets and Devices 5 Within the Add Targets and Devices dialog select the appropriate radio button depending on whether you already have an existing powered and configured RT target on the network or if you are adding a new RT target which is not present yet on the network a Existing Target or Device Expand the appropriate category in the Targets and Devices list to see the discovered targets in that category ii Double click the desired target to add it to your project b New Target or Device i Expand the appropriate category in the Targets and Devices list to see all possible targets within that category ii Double click the desired target to add it to your project 6 If the new RT target is not currently on the network right click on the RT target within the project and open the properties dialog to set the IP address or DNS name if necessary 7 Right click on the RT target within the project and navigate to New gt Targets and Devices Within the Add Targets and Devices dialog select the appropriate radio button depending on whether you already have an existing FPGA target connected to an existing RT target or if you are adding a new FPGA target which is not present yet a Existing Target or Device i Expand the appropriate category in the Targets and Devices list to see the discovered FPGA targets in that
26. st Connect the coil secondary to the spark tester device This connection will vary with coil and test device Be sure to connect the other side of the spark tester device back to battery ground The user should adjust the spark tester for a spark voltage of 10 20 kvolts Then starting with a dwell time of approximately 0 1 msec increase the dwell until spark is achieved Use the current probe to double check that current limits are not being exceeded as dwell is increased For example if the tester device were not connected properly for some reason the user would see current increasing with dwell but never see a spark and appropriate measures could be taken to discover the problem The dwell required for a 10 20 kvolt spark is most likely sufficient for achieving reliable combustion at moderate to high loads Of course this requirement will vary with many different factors but this test will provide the user with a typical dwell time for the given ignition coil During engine operation required dwell time will depend on battery voltage As battery voltage decreases dwell time must increase to achieve the same spark energy The user Drivven Inc 2009 Spark Driver Module Kit User s Manual e DO00012 Rev F 8 Drivven Inc Spark Driver Module Kit can perform a bench test with a variable power supply to determine how dwell time depends on battery voltage These values can be implemented in a lookup table in LabVIEW using Drivven s RT table
27. t_2mux4_revx vi contains 2 spark cores multiplexed into 4 outputs each SparkCore1 1 2 3 4 5 6 7 8 O O O 0 90 180 270 360 450 540 630 CAD Pulse numbers note the spark output channel Figure 8 spark_vt_1mux8_revx vi contains 1 spark core multiplexed into 8 outputs Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 18 Drivven Inc Spark Driver Module Kit NOTE The pulse output numbers shown in the plots above do not correspond to cylinder numbers There should be no attempt at cylinder number correlation to output channel number The reason is that spark channels must be configured with timing values in sequential CAD order NOT cylinder number order In order to determine which spark VI can be used the following calculations should be performed Assume EPT Stroke 4 MUX 8 1mux8 Maximum engine speed 6000 RPM MinDwellWindow sec 60 STROKE 2 MUX MaxEngineSpeed RPM 60 4 2 8 6000 0 002500 sec If MinDwellWindow is calculated to be less than the actual dwell required by the ignition coil then a VI should be selected with less multiplexing and the calculation should be performed again using the corresponding MUX value Do not forget to consider minimum battery voltage when determining maximum dwell required by the coil Drivven Inc 2009 Spark Driver Module Kit User s Manual e D000012 Rev F 19 Drivven Inc Spark Driver Module Kit Sub VI Documentation
28. tion coil with wasted spark mode disabled The spark driver module is internally protected from board temperature exceeding 85 degC When this temperature is exceeded all driver activity will be shutdown until the temperature drops to 55 degC The over temperature condition is reported by the SparkData cluster output of the FPGA VIs Drivven Inc 2009 Spark Driver Module Kit User s Manual D000012 Rev F 11 Drivven Inc Spark Driver Module Kit Software Installer The Spark Driver Module Kit is provided with an installer package which may be downloaded from Drivven s Sharepoint website after obtaining login access from Drivven User s may go to http portal drivven com SoftwareDownload and enter the provided username and password to gain access to the specific product installer packages which have been purchased The installer packages are executables which should be run on the intended development computer having LabVIEW development tools installed After installing the package a Start gt Programs gt Drivven gt ProductRelease menu item will be added to the desktop The specific product will have an example LabVIEW project appear under the Examples menu and the user manual will appear under the Manuals menu User s may copy and open the example project to experiment with the module or use as a starting point for a new application All software files example projects and documentation are installed to C Pro
29. to 16 bits Values larger than 16 bits will roll over from zero Dwell uint32 ticks Dwell msec 40 000 Drivven provides time2ticks vi in the General RT VIs in the RT function palette This VI can be implemented at the LabVIEW RT level for converting time in milliseconds to 40 MHz clock ticks MinDwell Determines the minimum length of any spark pulse It is possible that dwell could be cut short of the requested Dwell due to engine speed fluctuations or modifications to EndPosition If MinDwell is not satisfied upon reaching EndPosition then the pulse will be extended until MinDwell This will ensure that a spark will always occur even if the timing is late MinDwell should be set to a minimum value of dwell that will still guarantee a spark MinDwell is entered in terms of 40 MHz clock ticks and is internally limited to 200 000 ticks 5 msec The value is also internally limited to 18 bits Values larger than 18 bits will roll over from zero The following equation applies for converting dwell times in milliseconds to 40 MHz clock ticks Dwell uint32 ticks Dwell msec 40 000 Drivven provides time2ticks vi in the General RT VIs in the RT function palette This VI can be implemented at the LabVIEW RT level for converting time in milliseconds to 40 MHz clock ticks WasteSpark The WasteSpark input allows users to take advantage of dual output coils that operate on a pair of 4 stroke cylinders that are 360 degrees out of phase Whi
30. uld range from a few hundred microseconds to four milliseconds The voltage actually required for combustion will also depend on other engine parameters This spark driver module is intended to be used to drive a wide variety of ignition coils but the user must understand the proper range of dwell times for the coil used or damage to the coil and driver could occur It should also be understood that longer dwell time does not necessarily correlate to better combustion The dwell time only needs to be long enough to achieve a reliable spark under the engine operating conditions and battery voltage More dwell time in excess of what is needed to achieve reliable spark wastes energy and needlessly heats the driver module Determining Dwell Time The best way to determine required dwell time for a specific coil application is to measure the dwell of the coil within an OEM installation While performing measurements be sure to measure the dwell of at least three different battery voltages if possible in order to build a table of dwell times versus battery voltage If a datasheet is available for the coil a table of dwell versus battery voltage may be provided in order to achieve a certain peak current in the primary It is possible to safely determine the required dwell time for a given ignition coil by performing a simple bench test The test will require a variable voltage power supply capable of 7 peak amps an oscilloscope a current probe and a spar
Download Pdf Manuals
Related Search
Related Contents
m。squit。 buster Samsung Galaxy S5 mini Felhasználói kézikönyv Sistemas de Domótica. GE 591 Clothes Dryer User Manual MB075BH rev2 - Catalogue.bosal.com Saneamento Básico Integrado às Comunidades Rurais e AVC-5 Manual rB 9-8-11.vp JVC LT-17B60SU User's Manual Lenovo IdeaPad U330 Touch Copyright © All rights reserved.