WXD10B, WXD10, WXD20
Contents
1. iR 1 Unscrew both screws a from controller b and remove it from the base c 2 Cut the opening 205 x 92 mm in the panel 3 Knock out both cable inlet lids from the base Left inlet is for sensors right inlet is for power supply cables Put the base c into the panel cut out and fasten it with the inte grated hooks e 4 Carry out electrical connection put the controller b back to the base and fasten it with the screws a Installation manual 68 1 Place the console on the designated place of installation and mark the holes for cable inlets and screws 2 Cut the openings for cable inlets and drill the holes for screws ELECTRIC CONNECTION OF THE CONTROLLER Every heating controller project must be based on calculations and plans that are exclusively your own and pursuant to the regulations in force Im ages and texts in these manuals serve as examples and the issuer does not assume any responsibility for them Issuer liability for unprofessional false or incorrect information or consequential damage is explicitly excluded We reserve the right to technical errors or changes without giving prior notice Installation of controller devices shall be done by a qualifi
2. 408 WXD20 Solid fuel boiler oil boiler mixing circuit d h w storage tank Festbrennstoffkessel Fl ssigbrennstoffkessel Mischerheizkreis Brauchwasserew rmer EI Ki 4 N S Ott e k ses LL e T6 T3 163 408b WXD20 Solid fuel boiler gas boiler mixing circuit d h w storage tank Festbrennstoffkessel Gaskessel Mischerheizkreis Brauchwassererw rmer T2 AUHROUH 409 WXD20 Heat accumulator oil boiler mixing circuit d h w storage tank W rmespeicher Fl ssigbrennstoffkessel Mischerheizkreis Brauchwassererw rmer T2 2 HORROR 164 409b WXD20 Heat accumulator gas boiler mixing circuit d h w storage tank W rmespeicher Gaskessel Mischerheizkreis Brauchwassererw rmer 4 N HORROR e eal 410 WXD20 Heat accumulator oil boiler mixing circuit d h w storage tank W rmespeicher Fl ssigbrennstoffkessel Mischerheizkreis Brauchwassererw rmer 4 N HORROR DE 2 165 410b WXD20 Heat accumulator gas boiler mixing circuit d h w storage tank W rmespeicher Gaskessel Mischerheizkreis Brauchwassererw rmer T2 HORA 410c WXD20 Heat accumulato
3. Betrieb des Umschaltventils bei zwei 1 Einstellung der minimale drehzahl der pumpe 9 EI E UE Betriebsart bei F hlerdefekt un ne een MONTAGEANLEITUNG Montage des Reglers oie creen tnt ii tnnt ct RR LEER ue RR La PH S 144 Elle E 144 Montage in die Kessel ffnung ernennen nennen 145 Elektrischer Anschluss des Reglers eene nennn ent inna 146 Anschluss der Temperatutf hler cerne reds 147 Anschluss der Raumeinheit 002 eccesscccreeeeeecscenenescceeseceeeteneeseesnenerscenetneees 148 BUS Verbindung der WXD Regler eese nennen netten nnne 149 BUS Verbindung der WXD und CMP25 2 149 Montage und Anschluss des Sicherheitstermostates nennen 150 Service und Fehlerbehebung u seen 151 F hler Simulation und Steuerung Funkttonspr funmg nennen 151 Regler Defekt und W rtung 4 nes 151 Technische Daten E 152 GE Konformtitatserklarung u a ee en 153 Entsorgung von gebrauchten Elektrischen und Elektronischen Ger ten 153 Mydraulikscheme EE 154 81 BEDIENUNGSANLEITUNG BESCHREIBUNG DES REGLERS y m 1
4. 4014 WXD10B WXD10 WXD20 System with no boiler mixing circuit d h w storage tank System ohne Kessel Mischerheizkreis Brauchwassererw rmer 4 IN H Hin e el 156 401e WXD10B WXD10 WXD20 Expansion scheme mixing circuit d h w storage tank Erweiterungsschema Mischerheizkreis Brauchwassererw rmer 13 vr 112 GND ND 402 WXD10B WXD10 WXD20 Oil boiler direct circuit d h w storage tank Fl ssigbrennstoffkessel Direktheizkreis Brauchwassererw rmer 4 x N Ott e 157 403 WXD10B WXD10 WXD20 Oil boiler direct circuit d h w storage tank Fl ssigbrennstoffkessel Direktheizkreis Brauchwassererw rmer aj N THER 404 WXD10 WXD20 Oil boiler mixing circuit d h w storage tank solar collectors Fl ssigbrennstoffkessel Mischerheizkreis Brauchwassererwarmer Solarkollektoren oN e 158 404b WXD10 WXD20 Heat accumulator mixing circuit d h w storage tan
5. 0 14 to 0 34 mm Max cable length eren 30m 75 DECLARATION OF CONFORMITY Heating controllers WXD are conformed with the following directives LVD Low Voltage Directive 2006 95 EC EMC Electromagnetic Compatibility Directive 2004 108 EC RoHS Il Directive on hazardous substances in electrical and electronic equipment 2011 65 EC PRODUCT DESCRIPTION Boiler controller Model WXD10B WXD10 WXD20 STANDARDS USED EN60730 1 2001 EN60730 1 2001 A2 2009 EN60730 2 9 2002 EN60730 2 11 2008 EN61000 6 1 2007 EN55014 1 2007 EN12098 1 2002 76 DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT Disposal of old electrical and electronic equipment Applies to European Union Member States and other European countries with separate collection system This symbol on the product or its packaging indicates that it should not be dis posed as household waste Product must be submitted at the collection points for waste electrical and electronic equipment WEEE With the proper disposal of this product will prevent a negative impact on the environment and human health which could otherwise be caused by its erroneous removal Recycling materials reduces consumption of new raw materials For more information about recycling this product please contact the relevant departments waste disposal service or the shop where you bought it 77 NOTES 78 Witterungsgef hrter Heizungsr
6. Ei db s Operation according to selected time program Operation according to the selected time program with day and night tempera ture which is set on the controller Operation according to the selected time program with day and night tempera ture which is set on the room unit DD2 Operation mode according to day temperature Controller operates according to the requested day temperature which is set on controller Operation mode according to night temperature Controller operates according to the requested night temperature which is set on controller Switch off Controller is switched off Frost protection remains active if operation mode heating is selected Overheating protection remains active if operation mode cooling is selected OPERATION MODE FOR W W WARMING D h w warming according to selected time program D h w is warmed according to the selected time program Permanent activation of d h w warmin D h w warming operates continuously Switch off D h w is not being warmed The menu is only available in schemes with two heating circuits User manual 28 MANUAL OPERATION MODE This operation mode is used when testing the heating system or in the event of a malfunc tion Each control output can be manually switched on off or set to operate automatically T1 75 6 C T2 55 1 C T3 25 3 C T4 36 2 C T5 52 3 C Move between individual
7. fa 20 5 zc SG DA E WXD20 1 Graphisches Display 2 USB Anschluss f r PC 3 Tastatur 4 Programierbarer taste Bedienungsanleitung 82 REGLEREINSTELLUNG BEI DER ERSTINBETRIEBNAHME Die WXD Heizungsregler sind mit einer innovativen L sung Easy start die eine Erstein stellung des Reglers in nur drei oder vier Schritten erm glicht ausgestattet Beim ersten Anschlie en des Reglers ans Netz wird nach der Anzeige der Programmver sion und des Logos auf dem Display der erste Schritt zur Einstellung des Reglers ange zeigt 1 SCHRITT SPRACHENAUSWAHL Die gew nschte Sprache w hlt man mit den Tasten und aus Die ausgew hlte Sprache wird mit der Taste V best tigt Der Regler verlangt eine Best tigung der Richtigkeit der Mochten S e wirklich Sprachenauswahl mit der Taste V fortsetzen Haben Sie versehentlich die falsche Sprache ausge w hlt kehren Sie mit der Taste SD zur Sprachenaus wahl zur ck 83 Bedienungsanleitung 2 SCHRITT AUSWAHL DES HYDRAULIKSCHEMAS W hlen Sie das Hydraulikschema des Reglerbetriebs aus Zwischen den Schemen bewegt man sich mit den Tasten und Das ausgew hlte Schema Best tigt man mit der Taste V Alle Schemen mit Mischerheizkreisen sind f r Heizk rper und Boden Wand Heizung verf gbar Der Regler verlangt eine Best tigung der Richtigkeit Mochten S e wirklich des ausgew hlten Schemas mit der T
8. 61 Service setting manual OPERATION OF SWITCHOVER VALVE BY SYSTEMS WITH TWO HEAT SOURCES For control of switchower valve use 2 point actuator with spring return or classic 2 point actuator with phase return function Dot mark on hydraulic schemes indicates valve gate with open flow when the actuator is in base position It is advised to have this valve gate connected to the solid fuel boiler or heat accumulator or to supply pipe of liquid fuel boiler by scheme 121 With setting of parameter S5 16 1 the output R8 can operate inverted This setting pro vides further options of switchover valve connection as shown on pictures below SWITCHOVER BETWEEN TWO HEAT SOURCES Parallel connection Recommended default setting Optional setting S1 16 0 S1 16 1 LEGEND A liquid fuel boiler B solid fuel boiler or heat accumulator e valve gate with open flow when the actuator is in base position Service setting manual 62 Serial connection Recommended default setting Optional setting S1 16 1 LEGEND A liquid fuel boiler B solid fuel boiler or heat accumulator e valve gate with open flow when the actuator is in base position SETTING THE MINIMUM RPM FOR PUMP R9 A nominal system flow needs to be defined on behalf of installed collector surface Nominal system flow varies
9. Symbols for user functions sene Symbols for indication of temperatures and other data Symbols for protection functions Symbols for the indication of communication between devices Symbols for messages and warmmimgs nenn Help messages and warnings Entering and navigating through the Menu structure and description Temperature E User functions zu era Operation mode selection u nenn Time program settings EE Basic Settings E Data OvewieW een man SERVICE SETTINGS MANUAL Controller parameters errare tenere ee Userparameters iei te o ner ed er eet ne Era Heating CUME sosise tnn remate tede etie iaia ee EES EE Service paramieters 5 tiene rone etd eontra ck Parameters for floor drying nie default Settings EE Mixing heating circuit Basic operation descriptons Direct heating Circuit sient nee Liquid fuel boiler Solid hee UE Heat accumulator 13 Controlof the Neat ul EE Pump for return pipe temperature increase bypass pump Domestic hot Walter iniit hina ina Eo DR RE anda Domestic hot water circula
10. Switch over from liquid A to solid B fuel boiler or to heat accumulator When the heat source B temperature exceeds the switchover temperature PT point 1 the heat source A is switched off Switchover temperature PT is the highest temperature of listed below minimum temperature of heat source B increased for 10 C highest calculated stand pipe temperature for the mixing circuit 1 or 2 upper limit of this temperature is 5 K lower as set with parameter S5 12 measured d h w temperature increased for 10 C upper limit of this temperature is set with parameter S4 8 When the heat source B temperature aproaches to heat source A temperature the switchover valve turns to the heat source B point 2 Switch over from solid fuel boiler or heat accumulator B to liquid fuel boiler A If the heat source B temperature drops below switchover temperature PT point 3 and heating demand cannot be covered anymore the countdown to activate heat source A is started Bigger difference between required temperature and actual temperature of heat source B results in earlier activation of heat source A Smaller difference between required temperature and temperature of heat source B results in later activation of heat source A After the countdown the heat source A is switched on again point 4 When the heat source A temperature exceeds the heat source B temperature for 6 C the switchover valve turns to the heat source A point 5
11. Wenn ber die Woche keiner der Relaisausg nge eingeschal tet wurde schalten die sich am Freitag zwischen 20 00 und 20 15 Uhr selbstst ndig ein Umw lzpumpen laufen f r die Dauer von 60 s Mischventile und Umschaltventile drehen sich 30 s in eine und 30s in die andere Richtung Hier w hlt man an ob bei der Fernschaltung nur die lokale Fernschaltung ber cksichtigt wird oder ob auch die Fernschal tung des Hauptreglers ber cksichtigt wird Festgelegt wird auf welchen Kreis die Fernschaltung Einfluss hat Festgelegt wird der Typ zeitliche Konstante des beheizten Objekts F r massive und gut isolierte Objekte wird ein h herer Wert eingestellt F r Objekte von leichtem Bau und schlechter Isolation wird ein niedrigerer Wert eingestellt Mit der Einstellung kann eine der Funktionsarten des Relais ausgangs RO gew hlt werden 1 Zweite Stufe des Zweistufenbrenners 2 Zirkulation der Brauchwasser 3 Elektroheizk rper zur Erw rmung der Brauchwasser 4 Pumpe zur Mischung und Erh hung der R ckleitung in den Kessel Bypasspumpe erfordert ist auch die Einstellung von 1 4 9 f r T1 oder S1 5 12 f r T8 5 Haupt Kessel Pumpe 6 Regelung der W rmepumpe 118 Parameterbe Beschreibung des Parameters Einstellungs bernom zeichnung bereich mener Wert 1 FERNEIN SCHALTUNG 2 DIR KREIS VERZOG 3 DIR KREIS 4 KUHLUNG 5 BOOST 6 KESSEL BLOCKADE 7 BRENNER BETRIBS STUNDENZ H LUNG 1 LOKAL 2
12. Ausschaltdifferenz und Minimaltemperatur der Sonnenkollektoren Parameter P6 1 P6 2 und P6 3 bestimmt Das Brauchwasser wird bis zur Soll Temperatur die mit dem Parameter S4 10 eingestellt ist erw rmt 135 Wartungsanleitung Wenn das Brauchwasser erw rmt ist und die Kollektorentemperatur die Schutztemperatur der Sonnenkollektoren Parameter S6 1 berschreitet wird die Brauchwassererw rmung bis zur Maximaltemperatur des Brauchwassers Parameter S4 3 erlaubt Die Brauch wassererw rmung wird zwingend ausgeschaltet wenn die Brauchwassertemperatur die Maximaltemperatur Parameter S4 3 berschreitet oder wenn die Kollektorentemperatur Maximaltemperatur Parameter S6 2 berschreitet Wenn das Brauchwasser mit den Sonnenkollektoren erw rmt wird kann man mit dem Parameter S6 3 die Betriebsart des Kessels auf Fl ssigbrennstoff einstellen und zwar S6 6 1 der gleichzeitige Betrieb beider Heizquellen ist erm glicht S6 3 0 600 der Kessel schaltet sich mit der eingestellten Verz gerung seit der Abschal tung des Solarsystems ein Der Einstellwert ist die Verz gerungszeit in Minuten Brauchwassererw rmung mit Elektroheizk rper Der Ausgang RO oder R9 kann mit der Einstellung des Parameters 81 1123 oder S1 12 4 f r die Steuerung des Elektroheizk rpers f r die Brauchwassererw rmung programmiert werden Das Brauchwasser wird bis zur eingestellten Soll Temperatur erw rmt und arbeitet nach dem Zeitprogramm Nr
13. Parameters m Parameterwert MIN 401 423h E Einstellungsbereich Werkseinstellung des DEF 401 Parameters HYDRAULIKSCHEMA Beschreibung des Parameters Die Einstellung wird mit dem Dr cken auf die Taste V ver ndert Weil die Parameter werkseitig gesperrt sind erscheint eine neue Anzeige Hier muss man den Entsperrcode eintragen Mit den Tasten und stellt man sich auf die Ziffer die ver ndert werden soll und dr ckt die Taste V Wenn die fi 0 0 0 Ziffer blinkt kann man sie mit den Tasten und ver n dern und mit der Taste V best tigen Wenn der richtige code eingetragen ist entsperrt der Regler die Parameter amu und Sie werden zur ck zur ausgew hlten Parametergrup pe geleitet Das Eintragen des Entsperrcodes kann man mit der Taste SD verlassen Die Werkseinstellung f r den Code ist 0001 Der Parameterwert wird mit den Tasten oder ver ndert Die Einstellung best tigt man mit der Taste V Jetzt kann man sich mit den Tasten und zum anderen Para meter bewegen und das Verfahren wiederholen Die Parametereinstellungen verl sst man mit dem Dr cken der Taste 2 Die nderung der Wartungs und Funktionsparameter soll nur von Fachper sonal ausgef hrt werden 115 Wartungsanleitung Allgemeine Wartungseinstellungen Para Parameterbe Beschreibung des Parameters Einstellungs Ubernom meter zeichnung bereich mener Wert HYDRAULIKSCHE Auswahl d
14. Der Differenzregler kann bei den Schemas 408 408b 409 409b 410 410b Montageanleitungen 142 BETRIEBSART BEI F HLERDEFEKT Au enlufttemperaturf hler ist nicht angeschlossen bzw ist defekt Der Regler funktioniert in dem Fall als P Regler in Hinsicht auf die Raumtemperaturabwei chung Wenn der Raumtemperaturf hler auch besch digt oder nicht angeschlossen ist wird die Vorlauftemperatur vom Regler auf konstante Temperatur reguliert die bei der Radiatorheizung um 25 C h her liegt als die eingestellte Tages bzw Nachttemperatur bei der Fu bodenheizung um 10 C h her liegt als die eingestellte Tages bzw Nachttemperatur Vorlauftemperaturf hler ist nicht angeschlossen oder ist defekt Der Regler erkennt dass die Vorlauftemperatur 120 C betr gt und schaltet die Raumhei zung aus Die Heizung kann nur noch manuell aktiviert werden Fl ssigbrennstoffkesself hler ist nicht angeschlossen bzw ist defekt Der Regler nimmt an dass die Kesseltemperatur 85 C betr gt und schaltet gleichzeitig den Brenner an wenn Heizbedarf besteht In diesem Fall wird die Kesseltemperatur manu ell mit dem Kesselthermostat eingestellt Festbrennstoffkesself hler ist nicht angeschlossen bzw ist defekt Der Regler nimmt an dass die Temperatur des Festbrennstoffkessels 85 C betr gt und das Umschaltventil f r die Kessel dreht sich zum Festbrennstoffkessel Raumf hler ist nicht angeschlossen bzw ist defekt Der Regler funktionie
15. LOKAL UND MIT BUS 1 KREIS 1 2 KREIS 2 3 KREIS 1 UND 2 1 II STUF BRENNER 2 ZIRKULA Para meter ausgangs R9 gew hlt werden 1 Solardifferenz Thermostat 2 Kesseldifferenz Thermostat S1 4 9 f r T1 oder S1 5 12 6 Haupt Kessel Pumpe 7 Regelung der W rmepumpe T HLERABGLEICH Abweichung bei dem angezeig T wert des F hlers T2 kann hier T HLERABGLEICH Abweichung bei dem angezeig wert des F hlers T3 kann hier FUNKTION DES AUSGANGS R9 1 3 HLERABGLEICH Abweichung bei dem angezeig T wert des F hlers T4 kann hier 1 17 UHLERABGLEICH Abweichung bei dem angezeig T5 wert des F hlers T5 kann hier HLERABGLEICH Abweichung bei dem angezeig T6 wert des F hlers T6 kann hier Wl P F HLERABGLEICH Abweichung bei dem angezeig wert des F hlers T1 kann hier F 2 F F 4 F F F HLERABGLEICH Abweichung bei dem angezeig T wert des F hlers T7 kann hier F HLERABGLEICH Abweichung bei dem angezeig T wert des F hlers T8 kann hier 52 Parameterbe Beschreibung des Parameters Einstellungs zeichnung bereich Mit der Einstellung kann eine der Funktionsarten des Relais 3 Zirkulation der Brauchwasser 4 Elektroheizk rper zur Erw rmung der Brauchwasser 5 Pumpe zur Mischung und Erh hung der R ckleitung in den Kessel Bypasspumpe erfordert ist auch die Einstellung von r T8 en gemessenen Tempera nachkorrigiert werden en gemessenen Temp
16. s o Qo Quo io blo So Sio ello Glo Suo glo 1 Den Regler nehmen wir so auseinander das wir die Schrauben a und den Regler b aus dem Sockel c entfernen 2 Aus der Verpackung schneiden wir die Druckschablone aus zeichnen die Position der Bohrl cher ein und bohren sie 3 Den Sockel befestigen wir an der Wand mit vier beigelegten Schrauben 4 Wir f hren die elektrische Verbindung durch f gen den Regler a zur ck in den Sockel und Befestigen mit den Schrauben b Montageanleitungen 144 MONTAGE IN DIE KESSEL FFNUNG Die Kessel ffnungsmontage wird wie folgt ausgef hrt 8 SODOO00000000000 S o S 0 9000060000000 DEE E EE E EEN io CH e ej CH e Q000009000000 0000000000000 1 Wir entfernen die Schrauben und den Regler b aus dem Sockel 2 Am Boden des Sockels brechen wir beide L cher d aus und f hren durch das linke Loch die F hlerleiter und durch das Rechte Loch die Netzspannungsleiter 3 Den Sockel setzen wir in den Kesselausschnitt und befestigen ihn mit Befestigungsha ken vom Geh use e 4 Wir f hren die elektrische Verbindung durch f gen den Regler a zur ck in den Sockel und Befestigen mit den Schrauben b 145 Montageanleitungen ELEKTRISCHER ANSCHLUSS DES REGLERS Je
17. will not activate if d h w can be warmed to min FUEL BOILER OR HEAT _ temperature with solid fuel boiler or heat accumulator Set ACCUMULATOR ting 6 and 7 defines that d h w should always be warmed to requested temperature 6 with delayed switchover to controlled heat source 7 without delayed switchover to controlled heat source REQ D W TEMP BY With this setting is set requested d h w temperature if it is WARMING WITH COLL being warmed with solid fuel boiler or solar collectors ECTORS OR SOLID FUEL BOILER MIN AMBIENT TEMP D h w is warmed only with heat pump if ambient tempera FOR D W HEAT PUMP ture is above the set point temperature D h w warming from central heating system will activate when the ambient temperature drops bellow set point temperature Set para meter S1 4 8 for sensor T1 or S1 5 11 for sensor T8 to activate this function D H W WARMING PUMP Setting of d h water warming pump switch off delay after 0 10 min SWITCH OFF DELAY d h w was warmed D H W WARMING PUMP Setting of d h water warming pump switch off delay after 0 10 min SWITCH OFF DELAY d h w was warmed 49 Service setting manual Para meter 5 1 BURNER HYSTERESIS AND OPERATION MODE BOILER TEMPERATURE INCREASE FOR CIRCUIT 1 BOILER TEMPERATURE INCREASE FOR CIRCUIT 2 BOILER TEMP INCREASE FOR D H W WARMING BOILER STAND BY AT MIN TEMPERATURE BURNER SWITCH OFF BY SOL
18. Alle Reglereinstellungen aus der Sicherheitskopie werden geladen Wenn keine Sicherheitskopie vorhanden ist wird der Befehl nicht ausgef hrt Vor der Durchf hrung der einzelnen oben angef hrten Befehle verlangt der Regler eine Best tigung des ausgew hlten Befehls Wartungsanleitung 130 GRUNDFUNKTIONBESCHREIBUNGEN MISCHERHEIZKREISE Berechnung der Vorlauftemperatur Die Berechnung der Vorlauftemperatur ist nach oben mit der eingestellten Maximaltem peratur des Vorlaufs Parameter S2 6 und S3 6 und nach unten mit der eingestellten Minimaltemperatur des Vorlaufs Parameter S2 5 und S3 5 begrenzt Mit dem Parameter S2 1 und S3 1 wird die Intensit t der Wirkung der Raumtemperaturabweichung auf die Vorlauf Berechnung eingestellt Mit den Parametern P2 2 und P3 2 wird die Parallelver schiebung der Heizkurve eingestellt Heizung ausschalten Wenn die ausgerechnete Vorlauftemperatur nicht leicht h her ist als die Raumtemperatur schaltet sich die Heizung automatisch aus Wird die Raumtemperatur nicht gemessen schaltet sich die Heizung automatisch aus wenn die Au entemperatur fast gleich der Soll Raumtemperatur ist Mit dem Parameter S2 13 und S3 13 wird der Temperaturunterschied bei dem sich der Kessel ausschaltet vergr ert oder verringert Beim Ausschalten der Heizung wird 4 C als angenommener Wert f r die ausgerechnete Vorlauftemperatur bernommen und die Umw lzpumpe wird mit Verz gerung Parameter 2 16 und S3 16
19. Angabe die ver ndert werden soll aus Wenn die An gabe blinkt ver ndert man sie mit den Tasten und best tigt sie mit dem Dr cken der Taste V Die Einstellung verl sst man mit dem Dr cken der Taste gt Bedienungsanleitung 106 Displayeinstellung Es stehen folgende Einstellungen zur Verf gung 9 amp Dauer der aktiven Beleuchtung des Displays und des automatischen Verlas sens des Men s amp Intensit t der aktiven Displaybeleuchtung Intensit t der inaktiven Displaybeleuchtung Kontrast Mit den Tasten und V wird die gew nschte Einstellung ausgew hlt und best tigt Eine neue Anzeige erscheint Graphisches Symbol I Aktueller Einstellwert Numerisch Zuletzt best tigter Einstellwert Aktueller Einstellwert Graphisch Werkseinstellung Einstellbereich Aktueller Einstellwert Die Einstellung wird mit den Tasten und ver ndert und mit der Taste V wird sie best tigt Die Einstellung verl sst man mit dem Dr cken der Taste SD Die nderung der Einstellung wird erst nach der Best tigung mit der Taste V wirksam 107 Bedienungsanleitung a DATEN KONTROLLE Im Men befinden sich Ikonen die Ihnen den Zugang zu folgenden Betriebsangaben des Reglers erm glichen DARSTELLUNG DER TEMPERATUREN NACH TAGEN F R DIE LETZTE WOCHE Die graphische Darstellung des Temperaturverlaufs nach Tagen f r jeden F hler Es werden die Temperaturen f
20. Beschreibung des Parameters Einstellungsbe Ubernom meter reich mener Wert MINIMALE TEMP DER Einstellung der minimal geforderten Temperatur der KOLLEKTOREN ODER Sonnenkollektoren bzw Festbrennstoffkessel bei der DES FESTBRENN Sich die Solarpumpe einschalten kann STOFFKESSELS HEIZKURVENSTEILHEIT Mit der Einstellung der Heizkurve passen wir den Regler an das Objekt das wir regeln an Die richtige Einstellung der Heizkurve ist sehr wichtig f r den optimalen Betrieb des Reglers Die Steilheit der Heizkurve bestimmt wie hoch an Hand der Au entemperatur die Temperatur der Heizk rper sein soll Der Steilheitswert h ngt vor allem von der Art des Heizsystems Fu boden Wand Radiator und Konvenktorheizung und der W rmed m mung des Objekts ab Bestimmung der Heizkurvensteilheit Wenn gen gend Daten zur Verf gung stehen kann die Heizkurvensteilheit rechnerisch bestimmt werden ansonsten auf der Grundlage von Erfahrungen im Bezug auf die Bemes sungen des Heizsystems und der W rmed mmung des Objekts Die Heizkurvensteilheit ist richtig eingestellt wenn die Zimmertemperatur auch bei starken Schwankungen der Au entemperatur unver ndert bleibt Solange die Au entemperatur ber 5 C bleibt wird die Zimmertemperatur mit der Ver n derung der Einstellung der Tages bzw Nachttemperatur bzw mit einer Parallelverschie bung der Heizkurve Parameter P2 2 und P3 2 geregelt Wenn es im Geb ude bei niedrigeren Au en
21. Den Temperaturwert f r den ausgew hlten F hler stellt man mit der Taste oder ein Die Bezeichnung des simulierten F hlers ndert sich von T auf S Der Simulationsmodus wird unterbrochen wenn man 10 Sekunden die Taste gedr ckt h lt oder wenn l nger als 5 Minuten keine Taste gedr ckt wurde REGLER DEFEKT UND WARTUNG Im Falle von St rungen oder Sch den an den Regler senden Sie uns nur das Modul Der Sockel sollte montiert bleiben und die Kabel so angeschlossen wie sie sind Nehmen Sie den Regler auseinander wie folgt L sen Sie die Schrauben b und ziehen Sie das Regler Modul a zu sich Das Regler Modul wird ersetzt oder zu einen autorisierten Service Center geliefert Bevor Sie mit der Demontage des Reglers vom anfangen vergewissern Sie sich dass der Hauptzufuhrschalter ausgeschaltet ist 151 Deklarationen TECHNISCHE DATEN Technische Charakteristiken Regler Abmessungen i e ee 144 x 96 x 49 mm KN un 465g R glergehalise 3 sanieren SA PC Thermoplast Spannungsversorgung see 230V 50Hz Eigenverbrauch nnt eterne 5 VA Netzleiterquerschnitte 0 75 bis 1 5 mm2 Schutzstufe IP20 gem EN 60529 Sch tzkl asse zu nern I gem EN 60730 1 Zul ssige Umgebungstemperabr 5 C bis 40 C Zul ssige relative Feuchtigkeit m
22. E RESET OF CONTROLLER AND RE START OF THE FIRST SETTING Restores all parameters to default values and restarts the controller initial setup RESET SAVE USER SETTINGS Saves all controller settings as a safety copy CH Bd LOAD USER SETTINGS Uploads all controller settings from the safety copy If a safety copy doesn t exist this command is not executed EH 4 Before executing the commands listed above the controller requires a confir mation of the selected command Service setting manual 54 BASIC OPERATION DESCRIPTIONS MIXING HEATING CIRCUIT Stand pipe temperature calculation The upper limit of stand pipe temperature calculation is set with maximum stand pipe temperature parameters S2 6 and S3 6 lower limit is set with minimum stand pipe tem perature parameters S2 5 and S3 5 Parameters S2 1 and S3 1 are used to set the influ ence of room temperature deviation on the calculation of stand pipe temperature and with the parameters P2 2 and P3 2 you can adjust the parallel shift of heating curve Heating switch off If the calculated stand pipe temperature isn t for few C higher than the room temperature the heating is automatically switched off Heating is automatically switched off if room temperature is not measured and when the outdoor temperature approaches the required temperature The temperature difference between calculated stand pipe temperature and room temperature at which the boiler will swi
23. Fu boden oder Wand Heizung muss das Sicherheitsthermostat VT angeschlossen werden Man verwendet ein Kapillar Anlege oder Tauchthermostat mit Umschaltkontakt Er wird oberhalb des Vorlauftemperaturf hlers montiert Am Sicherheitsthermostat wird die h chste zugelassene Vorlauftemperatur f r die Fl chenheizung blicherweise zwi schen 40 und 60 C eingestellt beziehungsweise ein um minde stens 5 C h herer Wert als die am Regler eingestellte h chste zugelassene Vorlauftemperatur Parameter S2 6 bzw S3 6 PROMATIC WXD PROMATIC WXD Variante 1 Variante 2 Abschaltung der Umw lzpumpe bei Schlie ung des Mischventils bei berschreitung der Temperatur berschreitung der Temperatur Legende VT Sicherheitsthermostat Montageanleitungen 150 SERVICE UND FEHLERBEHEBUNG F HLER SIMULATION UND STEUERUNG FUNKTIONSPR FUNG Der WDC Regler ist mit einer besonderen Funktion versehen die eine Simulation aller F hler erm glicht Mit Hilfe dieser Funktion kann der Nutzer den Reglerbetrieb testen Die se Funktion dient der Inbetriebnahme Wartung oder Pr fung des Reglerbetriebs Die Simulation der F hler wird aktiviert indem man zuerst mit der Taste SD den Bildschirm mit der Anzeige des Hydraulikschemas ausw hlt Dann dr ckt und h lt man f r 10 Sekun den die Taste Der Regler schaltet auf den Simulationsmodus um Mit dem Dr cken der Taste V navigiert man zwischen den F hlern
24. Intervall Einstellungen f r den zweiten Heizkreis Para Parameterbezeichnung Beschreibung des Parameters Einstellungsbe meter reich Die Steilheit der Heizkurve bestimmt wie hoch an Hand der Au entemperatur die Temperatur der Heiz k rper sein soll Siehe Kapitel Heizkurvesteilheit Einstellen der Parallelverschiebung der Heizkurve beziehungsweise der errechneten Vorlauftemperatur Das Einstellen dient der Aufhebung der Differenz zwischen gew nschter und Ist Raumtemperatur Die Zeiteinstellung f r die gew nschte Dauer der Raumtemperaturerh hung beim bergang vom Nachttemperatur Intervall auf das Tagestemperatur Intervall Das Einstellen der Temperaturh he f r die h here gew nschte Raumtemperatur beim bergang vom Nachttemperatur Intervall auf den Tagestemperatur Intervall Einstellen der Steilheit der Heizkurve f r zus tzliche direkten Heizkreis Die Einstellung bedeutet parallele Verschiebung der Heizkurve f r zus tzlichen direkten Heizkreis Der Wert zwischen 16 und 90 bedeutet die gew nschte Kesseltemperatur wenn der zus tzliche direkte Heizkreis aktiviert ist Einstellungen f r das Brauchwasser GEW NSCHTE TEMPERATUR DER BRAUCHWASSER BEI AUSSCHALTEN DES ZEITPROGRAMMS VORRANG DER BRAUCHWASSE RERW RMUNG VOR KREIS 1 VORRANG DER BRAUCHWASSE RERW RMUNG VOR KREIS 2 Einstellung der gew nschten Brauchwassertempera tur wenn das Zeitprogramm f r die Brauchwasserw r mu
25. Kesseltemperatur Parameter S5 1 berschreitet wird das Brauchwasser bis zur Maximaltemperatur die mit dem Parameter S4 3 eingestellt ist erw rmt Wenn das Brauchwasser erw rmt ist schaltet sich die Umw lzpumpe mit Verz gerung aus Der Verz gerungswert ist mit dem Parameter S4 12 festgelegt Brauchwassererw rmung mit Festbrennstoffkessel Wenn der Festbrennstoffkessel in Betrieb ist wird Brauchwasser auf die Soll Temperatur eingestellt im Parameter S4 10 ohne R cksicht auf das Zeitprogramm f r die Brauchwas sererw rmung erw rmt Im Falle dass der Kessel die h chste Kesseltemperatur Parameter S5 13 berschreitet kann das Brauchwasser bis zur h chsten zugelassenen Brauchwassertemperatur Para meter S4 3 erw rmt werden Brauchwassererw rmung mittels Heizquelle mit eingebauter W rmepumpe In diesem Fall kann eine besondere Betriebsart der Brauchwasserregulierung die mit der Einstellung des Parameters S1 4 8 f r T1 oder S1 5 11 f r T8 aktiviert wird verwendet werden Im Raum wo sich die W rmepumpe befindet muss der Raumf hler T1 oder T8 angeschlossen werden Der Regler funktioniert so dass er die Brauchwassererw rmung aus dem Kessel der Zentralheizung blockiert solange der Raum in dem die W rmepumpe angebracht ist w rmer ist als eingestellt mit dem Parameter S4 11 Brauchwassererw rmung mit Sonnenkollektoren Die Grundfunktion des Solarsystems wird durch die Einstellungen der Einschaltdifferenz
26. Punkt 1 ber Schreitet schaltet sich die W rmequelle A aus Die Umschalttemperatur PT ist die h chste unter den folgenden Temperaturen Minimaltemperatur der W rmequelle B gesteigert um 10 C die h chste ausgerechnete Temperatur der Mischheizkreise Aufw rts ist die Temperatur begrenzt mit Parametereinstellung 55 12 minus 5K die ausgerechnete Brauchwassertemperatur gesteigert um 10 C Aufw rts ist die Tem peratur begrenzt mit Parametereinstellung S4 8 Wenn die Temperatur der W rmequelle B sich der Temperatur der Warmequelle A n hert dreht das Umschaltventil auf die W rmequelle B Punkt 2 Umschaltung von Festbrennstoffkessel oder Warmespeicher B auf Fl ssigbrennstoffkessel A Wenn die Temperatur der W rmequelle B unter die Umschalttemperatur PT Punkt 3 sinkt und den Heizbed rfnissen nicht mehr gen gt f ngt die Zeit der Verz gerung f rs einschalten der Heizquelle A zu laufen an Eine gr ere Differenz zwischen der ben tigten Temperatur f rs Heizen und der Let Temperatur der Heizquelle B bedeutet eine k rzere Verz gerung des einschalten der Heizquelle A und umgekehrt Die Umschalt Verz ge rungszeit beeinflusst auch der Parameter 55 15 Seite 126 Nach dem Ablauf der Verz gerung Schaltet erneut die W rmequelle A ein Wenn die Temperatur der W rmequelle A um 6 C die Temperatur der W rmequelle B berschreitet dreht sich das Umschaltventil auf die W rmequelle A Punkt 5 Wartungsa
27. T1 the required parameter setting is 81 421 If room sensor is connected to termi nal T8 the required parameter setting is 81 571 Installation manual 70 ROOM UNIT DD2 The WXD controllers enable connection of DD2 room unit which measures room temper ature and enables the setting of requested day and night temperature as well as selection of operation mode Up to two room units can be connected to a single WXD controller Setting of coding switches on room unit DD2 m Room unit is controlling circuit 1 m Room unit is not controlling circuit 1 m Room unit is controlling circuit 2 m Room unit is not controlling circuit 2 m The first room unit m The second room unit Scheme for connecting room unit DD2 The first room unit The second room unit 71 Installation manual BUS CONNECTION OF WXD CONTROLLERS With BUS connection any number of WXD controllers can be connected to network with WXD The first or the master controller physically controls heat sources while the other slave controllers control only the heating circuits Important Outdoor and boiler temperature sensors need to be connected to the master controller Outdoor sensor First controller Expanding controller Expanding controller Heat source GND 6 NSSWONS BUS CO
28. between 0 5 to 1 2 l min for each square meter of installed collectors or according to the manufacturer s recommendations example 3 solar collectors with total surface of 6 m2 need to have nominal system flow of 5 4 l min if basic flow in system is 0 9 Um for each square meter of installed collectors Next manually activate circulation pump R9 on max RPM see chapter Manual mode on page 29 Set pump speed switch to level where system flow is slightly higher as nominal flow in system Adjust the system flow with flow valve to match the nominal system flow Now set with the controller the R9 RPM to 40 and check on flow meter if there is flow in system If there is no flow in system raise the R6 RPM to 55 If there is still no flow in System raise the R9 RPM to 70 96 or raise the pump speed and repeat the whole procedu re again If min pump RPM was changed it needs to be set with parameter S6 11 63 Service setting manual DIFFERENTIAL CONTROLLER The WXD controllers feature programmable differential controller It can be activated by schemes with indication r by setting the parameter S1 12 1 for solar collector or S1 12 2 for solid fuel boiler Activation of differential controller function is possible if R9 T7 and T8 aren t used by scheme Output R9 is semi conductor relay and enables pump speed control APPLICATION OF DIFFERENTIAL CONTROLLER FOR SOLAR COLLECTORS Required parameter settings for application with storage tan
29. der Durchflussschalter des Brauchwassers angeschlossen Schlie t der Schalter schaltet der Regler die Umw lzpumpe zur Brauchwassserrzirkulation ein Laufzeit der Pumpe wird mit Parameter P4 8 eingestellt 6 BF2 Zusatzf hler im Erhitzer der Brauchwasser Einge baut im oberem Drittel des Erhitzers erm glicht er dass das Zuheizen der Brauchwasser erst dann einschaltet wenn der F hler BF2 es wahrnimmt 7 AGF Rauchgasf hler Erm glicht das Messen der Rauch gastemperatur Steigt die Temperatur ber den Wert S5 18 wird auf dem Bildschirm eine Meldung angezeigt 8 RFHP Zusatz Raumf hler im Raum wo die Heitzpumpe der Brauchwasser steht Solange der Raum w rmer ist als die Einstellung S4 11 wird das Heizen der Brauchwasser aus anderen Quellen nicht erm glicht 9 RLKF Taste der R ckleitung zum Kessel Der Regler begrenzt die niedrigste erlaubte Temperatur der R ckleitung in den Kessel die mit Parameter 55 14 bestimmt ist F r die Funktion ist die hydraulische Verbindung mit der f hrenden Umlaufpumpe des Kessels oder mit der Mischpumpe bypass notwendig Im Fall der Mischpumpe bypass ist auch die Einstellung von Parameter S1 11 4 auf RO oder S1 12 5 auf R9 notwendig 10 AGFTK Rauchgastemperaturf hler des Festbrennstoff kessels Der Regler blockiert die Funktion des Fl ssigbrenn stoffkessels wenn der Rauchgas die mit dem Parameter S5 19 eingestellte Temperatur berschreitet Wartungsanleitung 116 Par
30. die Funktion des Mischventilreglers MAXIMALE Mit der Einstellung wird die maximal erlaubte Temperatur 10 50 C TEMPERATUR DES des Estrichs bei Bodenheizung festgelegt ESTRICHS Die Einstellung wird nur dann angewendet wenn im Boden ein zus tzlicher F hler eingebaut wird Hierbei muss noch die Einstellung S1 5 2 ausgef hrt werden MINIMALE VOR Das Einstellen der minimalen Vorlauftemperatur f r die 10 20 C LAUFTEMPERATUR K hlung BEI KUHLBETRIEB ACHTUNG Eine zu niedrige Temperatur kann Kondensbil dung an Heizk rpern und Rohrleitungen verursachen ANSCHALTPUNKT Mit der Einstellung wird die minimale Vorlauftemperaturan 10 10 C VERSCHIEBUNG foderung korrigiert um die Regulierung des Mischventils DER VORLAUFTEM Zu aktivieren Geringere Werte bedeuten Aktivierung der PERATURREGE Regulierung bereits bei niedriger Errechnungen der Vorlauf LUNG temperatur h here Werte aktivieren die Regelung erst bei h heren Errechnungen der Vorlauftemperatur DIFFERENZBE Das Einstellen der maximalen erlaubten Differenz zwischen SCHR NK ZWI Vorlauf und R cklauf Auf diese Weise wird die maximale SCHEN VORLAUF Leistung des Heizkreises begrenzt UND R CKLAUF Differenzbeschr nkung aktivieren wir mit dem Parameter S1 5 3 KONSTANTE VOR Die Auswahl ob der Regler mit Konstanter Vorlauftempe LAUFTEMPERATUR ratur arbeiten soll Der Einstellungsbereich der konstanten Temperatur ist 10 140 C VORSICHT Durch diese Funk
31. erneuten Einstellung zur ck Die eingestellte Heizkurvensteilheit kann sp ter mit dem Parameter P3 1 ver ndert werden Die Bedeutung der Heizkurvensteilheit im Detail auf Seite 111 beschrieben RESET Stromversorgung des Reglers ausschalten Die Taste dr cken und halten und die Stromversorgung einschalten Der erste und der zweite Heizkreis ist auf dem Hydraulikschema mit einer Nummer gekennzeichnet Achtung Der Regler wird zur ckgesetzt und es bedarf einer erneuten Einstellung Alle vorherigen Einstellungen werden beim Zur cksetzen des Reglers gel scht 1 Bei Schemen mit einem Heizkreis gibt es diese Einstellung nicht 85 Bedienungsanleitung TASTATUR UND SONSTIGE TASTEN Beschreibung Bewegung nach links Wertabnahme Programierbarer taste Bedienungsanleitung 86 GRAPHISCHES LCD DISPLAY Alle wichtigen Daten sind auf dem LCD Display ersichtlich BESCHREIBUNG UND AUSSEHEN DER HAUPTANZEIGE Heizkreis Status der Steuerausg nge des Reglers Betriebsart Benutzerfunktionen Anzeige gemessener GE Temperaturen Raumeinheit T1 20 T3255 T5 45 7 C T2 5 T4 45 2 T6 53 8 C MS Y Ei TR1 A 20 0 21 02 04 OA Anzeige der Temperaturen Schutzfunktio nen und anderer Angaben Zeit und Meldungen und Datum Warnungen Anzeige der Angaben auf dem Display Die Betriebsart und Benutzerfunktionen werden getrennt f r jeden Heizkreis in dem oberen Drittel des Displa
32. highest power of heating STAND AND RETURN system is limited PIPE Limitation of difference between stand and return pipe is activated with parameter S1 4 3 for sensor T1 or S1 5 6 for sensor T8 CONSTANT STAND PIPE Selection of operation with constant stand pipe temperature 0 NO TEMPERATURE Setting range is 10 140 C 1 YES CAUTION This function deactivates weather compensated control of mixing valve CIRCULATION PUMP Setting of circulation pump switch off delay when there isno 0 10 min SWITCH OFF DELAY requirement for heating m s3 m s3 Service settings for the second heating circuit meter range setting INFLUENCE OF ROOM Set the influence of room temperature deviation Lower value 0 0 3 0 eee ee INFLUENCE OF ROOM Setting of room sensor T8 influence on the operation of second SENSOR T8 circuit 1 automatic room sensor influence room sensor has no influence if room unit DD2 is connected room sensor has influence if room unit DD2 isn t connected 2 room sensor has influence 3 room sensor has no influence This setting has affect only if S1 5 1 INFLUENCE OF DD2 Setting of DD2 room sensor influence on the operation of ROOM SENSOR first circuit 1 influence has only room unit DD2 controlling the first circuit coding switch on room unit S 3 OFF It can be set on first second or both room units 2 influence has only first room unit DD2 coding switch on room unit S 4 OFF 3 influenc
33. only one heating circuit 11 User manual KEYPAD AND OTHER KEYS Return back User manual Programmable key You can program the key as a shortcut to any place in the controller menu In the menu find a location where you want to program shortcut to point at then press and hold the button for 2 seconds This way the key was programmed Saved shortcut can be called up at any time by pressing the key 12 GRAPHIC LCD DISPLAY On the LCD display we can look up all the important data for the controller operation DESCRIPTION AND PRESENTATION OF THE BASIC SCREEN Heating circuit State of the controller s outputs Operation mode Active functions Measured temperatures Room unit T1220 T3255 T5245 7 C T2 5 T4 45 2 T6 53 T8 C D Ei TR1 A 20 0 202201 GA Temperatures protection functions and other data Time and Messages date and warnings Review of data on the screen In the middle of the screen are displayed operation mode and active user functions To switch between heating circuits and the screen with the hydraulic scheme review use the gt button Temperatures active outputs protection functions and other data appear in the bottom section of the screen To review temperatures and other data use buttons and The number of sensors and other data displayed on the screen depends on the selected hydraulic scheme and controller settings
34. outputs RO to R9 with buttons and Select the output by pressing the V button Value ON OFF or AUTO will begin to flash Now you can change the output status with buttons and Confirm the setting by pressing the V button Exit the setting by pressing the button 1 S i HEATING AND COOLING MODE SELECTION To switchover between heating and cooling select icon and press key V 4 Heating 3 4 Cooling PO EMISSION ANALYSIS Cooling control is operated thermostatically according to the requested room temperature with a constant stand pipe temperature The temperature is set with parameters 52 12 and 53 12 For cooling function a room sensor or a room unit DD2 needs to be con nected and the system for cooling water supply must be switched on When switching between heating and cooling you should change the re quested day and night temperature This operation mode is intended for emission measurement Controller activates burner and maintains boiler temperature between 60 C and 70 C by adequate activation of burner load heating circuits domestic hot water and in such way provides boiler operation without burner switch off s Function automatically expires after 20 minutes or it can be switched off earlier by selecting the icon once again Emission analysis can be activated with the button AH as well 29 User manual e TIME PROGRAM SETTINGS Weekly time programs enable automatic switchov
35. r die letzte Betriebswoche aufgezeichnet DETAILLIERTE DARSTELLUNG DER TEMPERATUREN F R DEN LAUFENDEN TAG Die detaillierte graphische Darstellung des Temperaturverlaufes f r den laufenden Tag f r jeden F hler Die H ufigkeit der Temperaturaufzeichnung wird mit dem Parameter P1 7 in Benutzer parameter auf Seite 109 eingestellt BETRIEBSSTUNDENZ HLER DER STEUERAUSG NGE Betriebsstundenz hler f r den Betrieb der Regler Steuerausg nge Ap G SPEZIELLE WARTUNGSDATEN Sie dienen dem technischen Dienst zur Diagnostik Um sich die F hler Graphe anzusehen bewegt man sich mit den Tasten und zwischen den F hlern Mit dem dr cken der Taste f ngt das Datum der angezeigten Temperatur an zu blinken Zwischen den Tagen bewegt man sich jetzt mit dem Tasten und Mit der Taste springen wir zur ck in die Temperatur Auswahl e S Mit der Taste kann die Reichweite der Temperaturanzeige auf dem Graph ge ndert werden Die Graph bersicht verl sst man mit der Taste Bedienungsanleitung 108 WARTUNGSANLEITUNGEN REGLERPARAMETER Alle zus tzlichen Einstellungen und Anpassungen des Reglerbetriebs werden mit Hilfe der Parameter ausgef hrt Benutzer Wartungs und Funktionsparameter befinden sich auf dem zweiten Men bildschirm Alle zus tzlichen Einstellungen und Anpassungen des Reglerbetriebs werden mit Hilfe der Parameter ausgef hrt Benutzer Wartungs und Funktionspa rameter
36. that causes liquid fuel boiler to switch off Monitoring period is 2 minutes Setting of solid fuel boiler protection temperature If this 70 90 C temperature is exceeded controller gradually starts to crease calculated stand pipe temperature in circuit 1 and 2 Setting of max solid fuel boiler temperature or heat accumulator temperature If this temperature is exceeded controller transfers surplus heat to d h w storage tank and heating circuits Limitation of max stand pipe temperature in heating circuits remains active Setting of min allowed boiler return pipe temperature for classic or high temperture boilers This setting is valid only by schemes with boiler return pipe limitation Also set parameter S1 4 9 for sensor T1 or S1 5 12 for sensor T8 By systems with two heat sources controller switches to heating with oil boiler when the deficit of heat occurs Switchover is carried out with delay Smaller value means higher heating comfort due to shorter delay by switchover higher value means higher energy saving due to longer delay by switchover 60 160 C 10 90 C 50 Default setting S xa Para meter INVERTED OUTPUT FOR SWITCHOVER BETWEEN HEAT SOURCES 55 17 FLUE GASES TEMP FOR SWITCHOVER TO SOLID FUEL BOILER MAX FLUE GASES TEMPERATURE MIN FLUE GASES TEMP FOR SOLID FUEL BOILER SWITCH OFF DIFFE RENCE FOR BOILER RETURN PIPE CONTROL EE PROTECTION OF MA
37. up of solid fuel boiler x Function switch off OPERATION MODE FOR THE FIRST HEATING CIRCUIT Operation mode according to selected time program ER Requested room temperature is set on the controller or room unit if connected Operation mode according to day temperature Requested room temperature is set on the controller Operation mode according to night temperature Requested room temperature is set on the controller Switch off The setting is only available in schemes with two heating circuits The setting is only available in schemes with changeover of heat sources 21 User manual OPERATION MODE FOR THE SECOND HEATING CIRCUIT Operation mode according to selected time program 2 Requested room temperature is set on the controller or room unit if connected Operation mode according to day temperature Requested room temperature is set on the controller Operation mode according to night temperature Requested room temperature is set on the controller Switch off D h w warming according to selected time program Permanent switch on of d h w warming Switch off Illi TIME PROGRAM FOR THE FIRST HEATING CIRCUIT 1 The first time program 22 The second time program TIME PROGRAM FOR THE SECOND HEATING CIRCUIT 1 The first time program 22 The second time program TIME PROGRAM FOR D H W 91 The first time program 2 The second time program The setting i
38. valve gradually opens up to the maximum stand pipe temperature parameters S2 6 and S3 6 The protection is deactivated when boiler temperature drops below the maximum boiler temperature HEAT ACCUMULATOR If temperature of heat accumulator drops below the set minimum heat accumulator tem perature parameter P5 3 the mixing valve will gradually begin to close If heat accumula tor temperature exceeds the maximum heat accumulator temperature parameter S5 13 the heat accumulator overheating protection is activated which opens the mixing valve up to the maximum stand pipe temperature parameters S2 6 and S3 6 The protection is deactivated when heat accumulator temperature drops below the maximum temperature 57 Service setting manual CONTROL OF THE HEAT PUMP Heat pump is main primary heat source in schemes 419 420 422 422b 422c and 422d Heat pump can be also activated as a primary heat sources in schemes 401b 404b 404d 404e 409 409b 410 410b 410c 411 416 416b 416c and 421 423b 423c 423d 423e Heat pump is activated with parameter S4 9 6 which is used to set alternative op eration mode of d h w circulation pump output Existing heat source oil boiler gas boiler or electric boiler is controlled as auxiliary secondary heat source Operation mode of heat pump and secondary heat source oil boiler electric boiler is set with parameters S6 17 S6 18 and S6 19 Parameter S6 17 defines minimum outdoor tempe
39. wenn die Au entemperatur unter den eingestellten Wert des Frostschutzes Parameter P1 3 f llt wenn die Kessel Vorlauf oder Raumtemperatur unter 4 C f llt Schutz des Fl ssigbrennstoffkessels Wenn die Temperatur des Fl ssigbrennstoffkessels unter die Minimaltemperatur des Kes sels Parameter P5 1 sinkt f ngt das Mischventil an sich stufenweise zu schlie en Im Falle dass die Temperatur des Fl ssigbrennstoffkessels die Maximaltemperatur des Kessels Parameter S5 1 berschreitet aktiviert sich der Kesselschutz Dann wird die Maximaltemperatur des Vorlaufs als Wert f r die ausgerechnete Vorlauftemperatur Pa rameter S2 6 und S3 6 angenommen Auch die Brauchwasserpumpe wird eingeschaltet Der Schutz schaltet sich aus wenn die Kesseltemperatur unter die Maximaltemperatur sinkt Steuerung des Zweistufenbrenners Wenn der Zweistufenbrenner gesteuert werden soll muss der folgende Parameter S1 11 1 durchgef hrt werden Die erste Stufe des Brenners wird mit dem R1 Relais gesteuert die zweite Stufe mit dem RO Relais Die zweite Stufe schaltet sich ein wenn die Kesseltemperatur um 4 C unter die Einschalt temperatur fur die erste Stufe fallt oder wenn die Kesseltemperatur mehr als 15 Minuten Uber der Einschalttemperatur fur die erste Stufe liegt Die zweite Stufe schaltet sich aus wenn die Kesseltemperatur weniger als 4 C unter der Ausschalttemperatur fur die erste Stufe liegt FESTBRENNSTOFFKESSEL Schutz d
40. wird mit dem erneuten Dr cken der Taste V beendet Das Einstellen des Zeitprogramms verl sst man mit Dr cken der Taste 20 Zeitprogramm kopieren Eine neue Anzeige mit dem Zeitprogramm f r den jeweiligen Tag wird ge ffnet In der oberen Displayh lfte befindet sich das Feld f r die Wahl des Wochentages oder Gruppe der Tage in die das Zeitprogramm kopiert werden soll Den Wochentag oder die Gruppe der Tage w hlt man mit den Tasten und aus F r das Kopieren wird die Taste V gedr ckt Das Kopieren verl sst man mit dem Dr cken der Taste 2 Werkseinstellungen der Zeitprogramme Erstes Zeitprogramm f r Raumheizung und Brauch wassererwarmung D1 MO FR 05 00 07 30 13 30 22 00 SA SO 7 00 22 00 Reumheizung Brauch _ Einschattintervan Raumheizung und Brauch Tag Einschaltintervall wassererw rmung D2 MO FR 06 00 22 00 SA SO 7 00 23 00 105 Bedienungsanleitung GRUNDEINSTELLUNGEN Das Men dient zur Einstellung der Sprache der Zeit des Datums und des Displays Sprachenauswahl Die gew nschte Benutzersprache w hlt man mit den Tasten aus und best tigt sie mit der Taste V Die Einstellung verl sst man mit dem Dr cken der Taste OD Zeit und Datum Die genaue Zeit und Datum werden wie folgt eingestellt e Etoo SA Zwischen den einzelnen Angaben bewegt man sich mit den Tasten und Mit der Taste V w hlt man die 22 01 2011
41. with a built in d h w storage tank mixing circuit Fl ssigbrennstoffkessel W rmespeicher mit eingebauten Brauchwassererw rmer Mischerheizkreis 4 M Lu e e 417 WXD20 Combined solid fuel oil boiler mixing circuit d h w storage tank Kombikessel Festbrennstoff Ol Mischerheizkreis Brauchwassererw rmer 4 N HORROR N e i 172 418 WXD20 Combined solid fuel oil boiler mixing circuit d h w storage tank Kombikessel Festbrennstoff Ol Mischerheizkreis Brauchwassererw rmer T2 HORROR e 419 WXD20 Heat pump direct circuit d h w storage tank W rmepumpe Direktheizkreis Brauchwassererw rmer M T2 HORROR e 173 420 WXD20 Heat pump additional electric heating direct circuit d h w storage tank W rmepumpe Nachw rmung mit Elektrik Direktheizkreis Brauchwassererw rmer site 4 D S HORA e ES e 9 9 9 9 9 9 9 9 9 421 WXD20 Oil boiler heat accumulator mixing circuit d h w storage tank Fl ssigbrennstoffkessel W rmespe
42. 2 f r die Brauchwassererw rmung F r die Steuerung des Elektroheizk rpers m ssen unbedingt ein Leistungsre lais und eine Thermosicherung eingebaut sein Vorrang der Brauchwassererw rmung vor der Raumbeheizung Mit dem Parameter P4 2 und P4 3 kann bestimmt werden dass die Brauchwassererw r mung Vorrang vor der Raumbeheizung hat Bei dem Direktheizkreis hat das Brauchwasser in der Regel den Vorrang R ckk hlung des Brauchwassers Recooling Wenn sich das Brauchwasser auf eine h here Temperatur als mit Parameter S4 3 einge stellt erw rmt k nnen wir mit dem Parameter S4 4 die R ckk hlung des Brauchwassers in die Kollektoren den Kessel oder beides aktivieren Impuls Modus der Kollektorpumpe Die Einstellung wird dann verwendet wenn der F hler nicht direkt im K rper der Kollek toren angebracht ist Einschaltung erfolgt mit Parameter S6 8 1 Wenn die Temperatur der Sonnenkollektoren die eingestellte Minimaltemperatur berschreitet schaltet sich alle 15 Minuten die Kollektorpumpe f r 10 Sekunden ein und stellt somit eine reell ausgerechnete Temperatur der Sonnenkollektoren sicher BRAUCHWASSERZIRKULATION Brauchwasserzirkulation Die Brauchwasser Zirkulationspumpe arbeitet nach dem ausgew hlten Zeitprogramm f r die Brauchwassererw rmung Parameter P4 7 Die Pumpe l uft in Intervallen und das zeitliche Verh ltnis zwischen Betrieb und Pause ist mit den Parametern P4 8 und P4 9 bestimmt Wartungsanleitung 136 Bra
43. 3 KEYPAD amp ERRORS ADVANCED DISPLAY OF Advanced display of temperatures displays temperatures TEMPERATURES on main screen in double rows First row is measured temperature second row is required or calculated temperature 1 M P2 Settings for the first heating circuit Para Parameter name Parameter description Setting range Default meter setting HEAT CURVE STEEP Heating curve steepness indicates what temperature is 0 7 floor NESS required for the heating bodies by a determined outdoor 4 0 temperature 1 See chapter Heating curve tors PARALLEL SHIFT OF Setting of parallel shift of heating curve or calculated HEATING CURVE stand pipe temperature Use this setting to eliminate deviation between actual and required room temperature DURATION OF BOOST Duration of boosted room temperature by changeover 0 200 min HEATING from night to day heating period ROOM TEMPERATURE Boost room temperature increase by changeover from INCREASE BY BOOST Night to day heating period HEATING Service setting manual 36 2 Settings for the second heating circuit Para Parameter name Parameter description Setting range Default meter setting HEAT CURVE STEEP Heating curve steepness indicates what temperature is 2 6 NESS required for the heating bodies by a determined outdoor 0 7 floor temperature 1 0 radia See chapter Heating curve tors PARALLEL SHIFT OF Setting of parallel shift of h
44. 3 ms ta 170 1648 25 107 80 1309 Tits 1s 190 1722 Service setting manual 66 INSTALLATION MANUAL CONTROLLER INSTALLATION Install controller in dry indoor area away from strong electromagnetic fields The controller is foreseen for wall installation or boiler panel installation with standard cutout of 138 x 92 mm WALL INSTALLATION The installation onto a wall is carried out in the following way DE E E EE EE 9 oOoooooooaooooQ oOoOoooolooooooOoO 0000060000000 1 Unscrew both screws a from controller b and remove it from the base 2 Remove the capillary of a safety temperature limiter d from the base Put the base on the wall align it with the built in level vial and mark the drilling holes 3 Drill the holes and insert the wall sockets 4 Fasten the base to the wall with supplied screws and carry out electrical connection At the end put controller b back to the base and fasten it with the screws a 67 Installation manual PANEL INSTALLATION The installation into a boiler panel cutout is carried out in the following way eo ioo Oro Qo ioo ee o lc Sie Glo eo So 600000100000000 ee ee ee 2220600600609
45. 8 eingestellt 8 SVS An den T8 Eingang schlie en wir den Brauchwas serdurchflussschalter Wenn der Schalter Schlie t schaltet der Regler die Pumpe f r die Brauchwasserzirkulation ein Laufzeit der Pumpe wird mit Parameter P4 8 eingestellt 9 BF2 Zusatzf hler im Brauchwasserspeicher Eingebaut wird er in das obere Drittel des Speichers und erlaubt das Zusatzheizen des Brauchwassers erst wenn der F hler BF2 das erkant hat 10 AGF Abgas F hler Erm glicht das Messen der Rauch gastemperatur Steigt die Temperatur ber den Wert S5 18 wird auf dem Bildschirm eine Meldung angezeigt 11 RFHP ein zus tzlicher Raumf hler im Raum wo wir eine W rmepumpe f r die Warmwasserbereitung haben Solange der Raum w rmer ist als die Einstellung S4 11 wird das Brauchwasser w rmen aus anderen W rmequellen verhindert 12 RLKF Taste der R ckleitung zum Kessel Der Regler begrenzt die niedrigste erlaubte Temperatur der R ckleitung in den Kessel die mit Parameter 5 14 bestimmt ist F r die Funktion ist die hydraulische Verbindung mit der f hrenden Umlaufpumpe des Kessels oder mit der Mischpumpe bypass notwendig Im Fall der Mischpumpe bypass ist auch die Einstellung von Parameter S1 11 4 auf RO oder S1 12 5 auf R9 notwendig 13 AGFTK Rauchgastemperaturf hler des Festbrennstoff kessels Der Regler blockiert die Funktion des Fl ssigbrenn stoffkessels wenn der Rauchgas die mit dem Parameter 5 19 eingestellte Temp
46. ANTE DER MISCHVENTILREGE LUNG 52 11 MAXIMALE TEMPERATUR DES ESTRICHS MINIMALE VOR LAUFTEMPERATUR BEI K HLBETRIEB Wartungsanleitung Das Einstellen des Abweichungsbereichs der Vorlauftempe ratur bei der die Mischventilregelung noch nicht reagiert Die Einstellung legt fest wie Intensiv der Regler die Stellung des Mischers korrigiert Ein Niedriger Wert bedeutet k rzere Verschiebungen ein gr erer Wert bedeutet L ngere Verschiebungen Die Einstellung legt fest wie oft der Regler die Stellung des Mischers korrigiert Ein niedrigerer Wert bedeutet eine seltenere und ein h herer Wert eine h ufigere Korrektur der Lage des Mischers Das Einstellen der Auswirkungsintensit t der Vorlauftempe ratur nderung auf die Funktion des Mischventilreglers it der Einstellung wird die maximal erlaubte Temperatur des Estrichs bei Bodenheizung festgelegt Die Einstellung wird nur dann angewendet wenn im Boden ein zus tzlicher F hler eingebaut wird Hierbei muss noch die Einstellung S1 4 2 f r T1 oder S1 5 5 f r T8 ausgef hrt werden Das Einstellen der minimalen Vorlauftemperatur f r die K hlung ACHTUNG Eine zu niedrige Temperatur kann Kondensbil dung an Heizk rpern und Rohrleitungen verursachen 120 MINIMALE VOR Einstellung der minimalen Vorlauftemperatur wenn die 10 90 LAUFTEMPERATUR Heizung funktioniert 85 Radia Para Parameterbezeich Beschreibung des Parameters Einstellungs Ube
47. AUS DER BRENNERFUNK Hysterese bestimmt 2 EIN TION 1 Das schalt Relais R1 schaltet ab wenn Heizung erfor 3 20 C derlich ist unabh ngig von der Temperatur der Heizquel HYSTERESE le Hiermit blockieren wir den Betrieb der Selbstst ndigen Heizanlage zum Beispiel Rotex Kessel 2 Das schalt Relais R1 schaltet ab wenn Heizung erfor derlich ist unabh ngig von der Temperatur der Heizquel le Hiermit blockieren wir den Betrieb der Selbstst ndigen Heizanlage zum Beispiel Gastherme oder W rmepumpe 3 bis 20 Hysterese zur Brennersteuerung Wartungsanleitung 124 Para meter KESSELTEMPERA TURERH HUNG WEGEN MISCHHEIZ KREIS 1 ERH HUNG DER KES SELTEMP WEGEN MISCHHEIZKREIS 2 ERH HUNG DER KES SELTEMP WEGEN BRAUCHWASSERER W RMUNG KESSELFUNKTION MIT MINIMALER TEMPERATUR AUSSCHALTEN DES BRENNERS BEI TEMP ERH HUNG DES FESTBRENNSTOFF KESSELS SCHUTZTEMPERATUR DES FESTBRENN STOFFKESSELS MAXIMALE TEMP DES FESTBRENNSTOFF KESSELS ODER W RMESPEICHER MINIMALE TEMP DER RUCKLAUF IN DEN KESSEL UMSCHALTVER Z GERUNG AUF KONTROLIERTE W RMEQUELLE INVERTIERTER AUSGANG F R UMSCHALTUNG VON W RMEQUELLEN Das Einstellen des Wertes um den die Kesseltemperatur h her sein so Heizkreis 1 als die errechnete Vorlauftemperatur f r Das Einstellen des Wertes um den die Kesseltemperatur h her sein soll als die errechnete Vorlauftemperatur f r Heizkreis 2 Mit
48. Brauchwassererw rmer 4 N HEAR e ex 415 WXD20 Combined solid fuel oil boiler heat accumulator with a built in d h w storage tank mixing circuit Kombikessel Festbrennstoff Ol W rmespeicher mit eing Brauchwassererw rmer Mischerheizkreis T2 HORROR 169 415b WXD20 Solid fuel boiler heat accumulator mixing circuit d h w storage tank Festbrennstoffkessel Warmespeicher Mischerheizkreis Brauchwassererwarmer 4 N AUHROUH nm 2 5 415c WXD20 Oil boiler solid fuel boiler heat accumulator with a built in d h w storage tank mixing circuit Fl ssigbrennstoffkessel Festbrennstoffkessel W rmespeicher mit eingebauten Brauchwasserw rmer Mischerheizkreis T2 i Lu 170 446 WXD20 Oil boiler heat accumulator mixing circuit d h w storage tank Fl ssigbrennstoffkessel Warmespeicher Mischerheizkreis Brauchwassererwarmer T2 HORA 416b WXD20 Gas boiler heat accumulator with a built in d h w storage tank mixing circuit Gaskessel Warmespeicher mit eingebauten Brauchwassererwarmer Mischerheizkreis i 2 n T 2 GND M TS 171 416c WXD20 Oil boiler heat accumulator
49. D2 F HLEREIN FLUSS Einstellen der Auswirkung der Raumtemperaturabweichung auf die errechnete Vorlauftemperatur Niedrige Werte bedeuten kleinere Auswirkungen und h he re Werte st rkere Auswirkungen auf den Regler Mit der Einstellung bestimmen wir ob der Raumf hler T8 auf die Funktionsweise vom zweiten Heizkreiss Einfluss hat 1 Automatik betrieb bedeutet das der Raumf hler Einfluss hat wenn die Raumeinheit DD2 nicht angeschlossen ist Der Raumf hler keinen Einfluss hat wenn die Raumein heit DD2 angeschlossen ist 2 der Raumf hler hat Einfluss 3 der Raumf hler hat keinen Einfluss Diese Funktion hat nur Bedeutung wenn der Parameter S1 5 1 ausgew hlt ist Mit der Funktion stellen wir den Einfluss der F hler der Rau einheiten DD2 auf dem Betrieb des zweiten Heizkreises 1 Einfluss hat der F hler der Raumeinheit DD2 die den zweiten Kreis regelt Kodier Schalter der Raumeinheit S 3 OFF Dies k nnen die erste die Zweite oder beide Raumeinheiten sein 2 Einfluss hat der F hler der ersten Raumeinheit DD2 Kodier Schalter der Raumeinheit S 4 OFF 3 Einfluss hat der F hler der zweiten Raumeinheit DD2 Kodier Schalter der Raumeinheit S 4 ON 4 Einfluss haben beide F hler der Raumeinheiten DD2 5 Der F hler der Raumeinheit DD2 hat keinen Einfluss 121 Wartungsanleitung Para Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom meter nung bereich mener Wert BETR
50. Displaybeleuch tung aus bzw wird gem der Einstellung verringert MEN STRUKTUR UND BESCHREIBUNG E TEMPERATUREINSTELLUNG x Tagestemperatur f r Kreis 1 lt lt M Nachttemperatur f r Kreis 1 m Tagestemperatur f r Kreis 2 amp 2 Nachttemperatur f r Kreis 2 Brauchwassertemperatur Funktionen stehen nur bei Schemen mit zwei Heizkreisen zur Verf gung 93 Bedienungsanleitung ECO Modus Urlaubsmodus Funktion abschalten BENUTZERFUNKTIONEN F R DEN ZWEITEN HEIZKREIS PARTY Modus EU ECO Modus 00 Urlaubsmodus x Funktion abschalten BENUTZERFUNKTIONEN FUR DAS BRAUCHWASSER m Einmaliges Einschalten der Brauchwassererw rmung Funktion abschalten BENUTZERFUNKTIONEN F R ENERGIEQUELLEN ar Einmaliges Einschalten des Fl ssigbrennstoffkessels Blockierung Abschaltung des Fl ssigbrennstoffkessels Festbrennstoffkessel Einschaltung Funktion abschalten BETRIEBSART F R DEN ERSTEN HEIZKREIS Betrieb nach dem ausgew hlten Zeitprogramm Soll Raumtemperatur Einstellung am Regler oder an der Raumeinheit wenn die angeschlos sen ist Betrieb nach der Tagestemperatur Soll Raumtemperatur wird am Regler eingestellt Betrieb nach der Nachttemperatur Soll Raumtemperatur wird am Regler eingestellt Funktionen stehen nur bei Schemen mit zwei Heizkreisen zur Verf gung Funktionen stehen nur bei Schemen mit Umschaltung von W rmequellen z
51. Drehzahl 3 70 der Drehzahl Wenn die Differenzbedingung erf llt ist schaltet sich ge m der Zeiteinstellung die Solarpumpe mit maximalem Pumpenbetrieb ein Nach Ablauf dieser Zeit beginnt die RPM Modulation wenn diese eingeschaltet ist 86 1021 5 3005 20 127 Wartungsanleitung Para Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom meter nung bereich mener Wert EINBAUORT DES Mit der Einstellung wird festgelegt was mit der Solarpum 1 BRAUCH KALTF HLERS BEIM pe beheizt wird beziehungsweise wo der Kaltf hler T8 des WASSERER DIFFERENZTHERMO Differenzthermostats angebracht wird W RMER 2 W RME SPEICHER W RMEPUMPE Eingestellt wird ob die W rmepumpe durch st ndige 1 ON OFF BETRIEBSART Einschaltung oder Wetterbedingt gesteuert wird 2 WITTE RUNGSGE F HRT Eingestellt wird die maximale Arbeitstemperatur der W rmepumpe bei witterungsgef hrte Steuerung W RMEPUMPE MIN Eingestellt wird die Grenzau entemperatur unter welcher AURENTEMP FUR die Tatigkeit der Pumpe bedingungslos abgeschalten 10 ABSCHALTUNG wird Wartungsanleitung 128 PARAMETER F R ESTRICHTROCKNUNG In der Gruppe F1 befinden sich die Parameter zur Einstellung der Estrichtrocknung Das Verfahren f r die Einstellung der F Parameter ist der gleiche wie f r die Wartungseinstellungen Seite 115 dd Parameter f r Estrichtrocknung Parameterbezeichnung Einstellungsbereich
52. ENG Weather compensated heating controller DEU Witterungsgef hrter Heizungsregler WXD10B WXD10 WXD20 ag TRI 22 0 CE 20 5 E 12 29 MON 2 2 2002 DA H al 229 D o pa W Weather compensated heating controller WXD10B WXD10 WXD20 Witterungsgef hrter Heizungsregler WXD10B WXD10 WXD20 2 Weather compensated heating controller WXD10B WXD10 WXD20 IMS Y E TRI 22 0 CE 20 5 sch Ee 12 29 MON 25 12 2012 OA MM om INTRODUCTION Boiler controller WXD are modern microcontroller based devices produced in digital SMT technology WXD controllers are intended for boiler control of direct and or mixing heating circuit or two mixing heating circuits and d h w warming with boiler solar collectors and other energy sources WXD controllers also incorporate safety temperature limiter STB for emergency boiler shutdown For initial setup see Initial controller setup page 9 CONTENTS E Controller descriplioni c encarar ruit er en Initial controler Setup inrer e Keypad other keys u een Graphic Ber RRE EE Description and presentation of the basic screen Description of symbols presented on the display Symbols for heating circuits Symbols for operation mode indication
53. Einstellung S1 4 9 f r T1 oder S1 5 12 f r T8 Bei Systemen mit zwei W rmequellen wird die Umschal tung auf kontrollierte W rmequellen ausgef hrt wenn ein bestimmtes Niveau des W rmeverlusts f r die Heizung erreicht ist Ein geringerer Wert bedeutet schnellere Umschaltung und damit h heren Komfort und ein h herer Wert der Einstellung sp tere Umschaltung und damit gr ere Ersparnisse Bei Schemata mit zwei W rmequellen wird mit der Einstellung invertierte Funktion des Steuerausgangs f r das Umschaltventil eingestellt 125 Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom nung bereich mener Wert 1 NUR TAGS 10 90 C 1 INVERTIERT Wartungsanleitung Para Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom meter nung bereich mener Wert 5 17 TEMP DER RAUCH GASE FUR UMSCHAL TUNG AUF FESST BRENNSTOFFKESSEL MAXIMALE RAUCH GASTEMPERATUR MINIMALE RAUCH GASTEMPERAT DES FESTBRENNSTOFF KESSELS AUSSCHALTDIF FERENZ BEI DER REGULATION DES RUCKLAUFS IN DEN KESSEL SCHUTZ DER MAXIMA LE TEMPERATUR DER KOLLEKTOREN ODER DES FESTBRENN STOFFKESSELS MAXIMALE TEMPERA TUR DER KOLLEK TOREN ODER DES FESTBRENNSTOFF KESSELS SICHERHEITSAB SCHALTUNGSTEMPE RATUR FUR SONNEN KOLLEKTOREN ODER FESTBRENNSTOFF KESSEL Wartungsanleitung Bei Schemen 117 und 118 mit Kombi Kesseln kann ein F hler f r Rauchgase f r Festbrennstoffkesse
54. ID FUEL BOILER TEMP INCREASE SOLID FUEL BOILER PROTECTION TEMP MAX SOLID FUEL BOILER OR HEAT ACCU MULATOR TEMP MIN BOILER RETURN PIPE TEMP SWITCHOVER DELAY TO CONTROLLED HEAT SOURCE Service setting manual Service settings for boilers Parameter description MAXIMUM BOILER TEM Setting of maximal liquid fuel boiler temperature PERATURE Setting range 60 160 C 1 SWITCH OFF 2 SWITCH Setting of burner operation mode and hysteresis 1 Relay is energized ifthere is no demand for heating regardless to heat source temperature This way we block operation of heat sources with independent controller Such control is required for Rotex boilers 2 relay is energized when there is need for heating re gardless to heat source temperature This way we activate operation of independent heat sources such as wall hung gas boiler or heat pump 3 20 burner control hysteresis HYSTERE SIS Setting of boiler temperature increase in comparison with calculated stand pipe temperature for circuit 1 Setting of boiler temperature increase in comparison with calculated stand pipe temperature for circuit 2 Setting of boiler temperature increase in comparison with requested d h w temperature 0 ON 1 DAY TEMP PERIOD 2 OFF Setting of boiler stand by at min boiler temperature This setting has affect only if heating operation mode is ive Setting of solid fuel boiler temperature increase
55. IEBSART DER Einstellung der Betriebsart der Umw lzpumpe Einstellungen 1 STAND UMW LZPUMPE haben folgende Bedeutung 2 AUS 1 Standard Einstellung der Mischkreis Umw lzpumpe 3 ZEITPR P1 2 Ausschalten der Pumpe wenn die Raumtemperatur 4 ZEITPR P2 erreicht ist nur bei direktem Heitzkreis 5 GEW PR 3 Arbeitet nach Zeitprogramm P1 4 Arbeitet nach Zeitprogramm P2 5 Arbeitet nach dem Ausgewahlten Zeitprogramm MINIMALE VOR Das Einstellen der minimalen Vorlauftemperatur wenn die 10 90 LAUFTEMPERATUR Heizung in Betrieb ist MAXIMALE VOR Das Einstellen der Begrenzung der maximalen Vorlauftem 20 150 C 45 Fu bo LAUFTEMPERATUR peratur den 85 Radia toren STILLSTAND DER Das Einstellen des Abweichungsbereichs der Vorlauftempe MISCHVENTILREGE ratur bei der die Mischventilregelung noch nicht reagiert LUNG P KONSTANTE DER Die Einstellung legt fest wie Intensiv der Regler die Stellung MISCHVENTILREGE des Mischers korrigiert Ein Niedriger Wert bedeutet k rzere LUNG Verschiebungen ein gr erer Wert bedeutet L ngere Verschiebungen des Mischventils I KONSTANTE DER Die Einstellung legt fest wie oft der Regler die Stellung MISCHVENTILREGE des Mischers korrigiert Ein niedrigerer Wert bedeutet eine LUNG seltenere und ein h herer Wert eine h ufigere Korrektur der Lage des Mischers D KONSTANTE DER Das Einstellen der Auswirkungsintensit t der Vorlauftempe MISCHVENTILREGE ratur nderung auf
56. IONEN F R BRAUCHWASSER Einmaliges Einschalten der Brauchwassererw rmun Die Funktion aktiviert die unverz gliche Brauchwassererw rmung auf die Soll Temperatur Wenn die Soll Temperatur des Brauchwassers erreicht ist schaltet sich die Funktion auto matisch aus Mit den Tasten und w hlt man die Funktion einmaliges Einschalten der Brauchwassererw rmung aus und aktiviert sie mit der Taste Die Einstellung verl sst man mit dem Dr cken der Taste SD BENUTZERFUNKTIONEN F R ENERGIEQUELLEN Einmaliges Einschalten des Fl ssigbrennstoffkessels Diese Funktion aktiviert die unverz gliche Umschaltung der Heizung vom Festbrennstoff kessel oder Speicher auf Fl ssigbrennstoffkessel Das einmalige Einschalten des Fl ssig brennstoffkessels wird nur dann aktiviert wenn im Festbrennstoffkessel oder W rmespei cher eine zu geringe Heizwassertemperatur vorhanden ist Mit den Tasten und w hlt man die Funktion einmaliges Einschalten des Fl ssigbrennstoffkessels aus und aktiviert sie mit der Taste V Die Einstellung verl sst man mit dem Dr cken der Taste 5 Blockieren Abschalten des Fl ssigbrennstoffkessels Diese Funktion wird dann verwendet wenn man die Heizung mittels Fl ssigbrennstoffkes sel ausschalten m chte und nur mit dem Festbrennstoffkessel heizen will Die Funktion hat keine automatische Unterbrechung und muss daher manuell ausgeschaltet werden Mit den Tasten und w hlt man die Funktion Abschalten
57. Ifyou wish to retrieve the requested data after using the keyboard look for the data with buttons and then confirm it by pressing the V button for 2 seconds If you press the SD button for 2 seconds the temperature review will change from a single line review into a double line review or vice versa In the two line temperature review the measured temperature appears in the first line and the requested or the calculated temperature appears in the second line 13 User manual DESCRIPTION OF SYMBOLS PRESENTED ON THE DISPLAY SYMBOLS FOR HEATING CIRCUITS Description The first mixing heating circuit The second direct or mixing heating circuit D h w warming Description Room heating Room cooling Operation according to program timer day temperature Operation according to program timer night temperature Requested day temperature operating mode Requested night temperature operating mode PARTY operation mode ECO operation mode Holiday operation mode One time d h w warming The number indicates the first or the second time program User manual 14 Anti legionella protection Liquid fuel boiler switched off blocked z Solid fuel boiler switch on Automatic switchover to summer heating mode SYMBOLS FOR INDICATION OF TEMPERATURES AND OTHER DATA Measured temperature E Calculated or requested temperature CECR Ten o Trennen nn
58. LDSCHIRM F R HILFE MELDUNGEN UND WARNUNGEN Mit dem Dr cken der Taste wird der Bildschirm f r Hilfe Meldungen und Warnungen auf gerufen Ein neues Fenster wird ge ffnet in dem folgende Ikonen zur Verf gung stehen B Elver e fF P 8 Kurzanleitung Kurzanleitung f r die Bedienung des Reglers Reglerversion Anzeige des Typs und des Ger tesoftwarestands des Reglers Meldungen Die Liste der berschreitungen der Maximaltempetatur und die Liste der Akti vierungen der Schutzfunktionen Mit dem Dr cken der Taste und bewegt man sich in der Liste mit den Meldungen hin und her Mit der Taste SD verl sst man die Liste Warnungen Fehlerliste f r F hler und andere Baugruppen Mit dem Dr cken der Taste und bewegt man sich in der Liste mit den Warnungen hin und her Mit der Taste 5 verl sst man die Liste L schen der Warnungen Mit dem Dr cken der Taste werden die F hler die nicht angeschlossen sind gel scht Achtung F hler die f r den Betrieb des Reglers notwendig sind k nnen nicht gel scht werden Bedienungsanleitung 92 EINSTIEG UND NAVIGATION IM MEN mz Ri TR1 A 20 0 2052 OA Um das Men zu ffnen dr ckt man die Taste V Innerhalb des Men s bewegt man sich mit den Tasten und mit der Taste V best tigt man die Auswahl Um zur vorigen Anzeige zur ckzukehren die Taste SD dr cken Wenn einige Zeit keine Taste gedr ckt wird schaltet sich die
59. NEIN SCHUTZ len aktiviert 4 LEGIONELLEN Eingestellt wird der Einschalttag des Legionellenschutzes SCHUTZ EINSCHALT TAG LEGIONELLEN Eingestellt wird die Einschaltuhrzeit des Legionellen SCHUTZ EINSCHALT Schutzes UHRZEIT BERHITZUNGS Mit der Einstellung wird die gew nschte Funktionsweise SCHUTZ DES des Schutzes vor berhitzung des Brauchwassers 1 IN KOLLEK BRAUCHWASSERS aktiviert Wenn die Temperatur im Brauchwasserheizer die TOREN H chsttemperatur S4 3 berschreitet wird die R ckk h 2 IM KESSEL lung eingeschaltet wenn dies m glich ist 3 KOLL UND 1 in die Kollektoren 2 in den Kessel 3 in die Kollektoren und in den Kessel 123 Wartungsanleitung Para Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom meter nung bereich mener Wert MIN BRAUCHWAS Wenn es m glich ist mit Festbrennstoffkessel oder 1 45 C SERTEMP BEIM HEI Pufferspeicher das Brauchwasser bis zur min Temperatur 2 50 C ZEN MIT FESTBRENN zu erhitzten wird sich f r dem Bedarf der Brauchwas 3 55 C STOFFKESSEL ODER sererw rmung die zus tzliche Quelle nicht einschalten 4 60 C W RMESPEICHER Fl ssigbrennstoffkessel W rmepumpe Elektrik 5 65 C Wird die Einstellung 6 oder 7 ausgew hlt muss das 6 KEINE Brauchwasser immer bis zur gew nschten Temperatur EINSCHR erhitzt werden 7 KEINE 6 mit Heizquellen Umschaltverz gerung EINSCHR IST 7 ohne Heizquellen Umschaltverz geru
60. NNECTION TO WHMS CONTROLLERS With BUS connection any number of WXD with WHMS controllers can be connected to network The first or the master controller physically controls heat sources while the other slave controllers control only the heating circuits Important Outdoor and boiler temperature sensors need to be connected to the master controller Outdoor sensor Expanding controller Expanding controller First controller Scheme 360b Scheme 360b mmm Heat source Installation manual 72 INSTALLATION AND CONNECTION OF VT SAFETY LIMITER stalled rameters 2 6 and S3 6 Example 1 Exceeding the safety limiter temperature will deactivate the circulation pump Legend VT safety limiter 73 In the case of floor or wall heating a safety limiter VT should be in Use a capillary tube wall surface or an immersion thermostat with a switching contact Install it above the stand pipe sensor Set the maxi mum allowed stand pipe temperature for floor heating usually between 40 C and 60 C or the temperature which is at least 5 C higher as the set maximum allowed stand pipe temperature on the controller pa Example 2 Exceeding the safety limiter temperature will close the mixing valve Installation manual CONTROLLER MALFUNCTION SENSOR SIMULATION AND CONTROLLER OPERATION TEST The WXD controllers have a speci
61. NSOR FOR DIFF THERMOSTAT Setting of max heat pump output temperature when operating in weather compenstaed mode HEAT PUMP MAX SUPPLY WATER TEMPE RATURE Setting of min outdoor temperature below which the heat pump should switch off HEAT PUMP MIN OUT DOOR TEMP FOR HEAT PUMP OPERATION 6 17 Service setting manual 52 HEAT PUMP OPERATI Setting of hysteresis for heat pump operation 2 10 C ON HYSTERESIS Default Parameter name Parameter description Setting range setting 1 PARALELL 0 600 MIN DELAY OF LIQUID FUEL BOILER 1 D H W 2 CIRCUITS 3 BOTH 0 NO 1 YES 2 YES SWITCH ON 0 ON OFF 1 RPM 1 D H W TANK 2 HEAT AC CUMULATOR 1 ON OFF 2 WEATHER COMPENSA TED Para Parameter name Parameter description Setting range Default meter setting HEAT PUMP OUTDOOR Setting of outdoor temperature for bivalent operation TEMP FOR BIVALENT mode of heat pump and other heat source Below setted OPERATION MODE temperature the controller makes switchover between heat sources immediately when heat pump cannot supply requested temperature Above setted temperature the controller makes switchover between heat sources on behalf of temperature deficit i e with delay This principle of switchover between heat sources provides maximum efficiency and optimal use of heat pump even when it solely cannot cover complete heating demand HEAT PUMP MIN Setting of minim
62. RA TUR DES WARMESPEI CHERS VERBRAUCH DES FLUSSIGBRENNSTOFF KESSELS 1 STUFE VERBRAUCH DES FLUSSIGBRENNSTOFF KESSELS 2 STUFE ENERGIETR GER F R FL SSIGBRENNSTOFF KESSEL Einstellung der minimal Temperatur des Fl ssigbrenn stoffkessels Einstellung der minimal Temperatur des Fl ssigbrenn stoffkessels ung der Temperatur bis zu welcher W rme peicher entzogen werden kann ung des Verbrauchs beim Fl ssigbrennstoff 1 Stufe L h oder Sm3 h Einstellung des Verbrauchs beim Fl ssigbrennstoff kessel 2 Stufe L h oder Sm3 h Auswahl des Energietr gers f r den Fl ssigbrenn stoffkessel Einstellungen f r alternative Energiequellen 1 PROG 1 2 PROG 2 3 AUSGEW PROG 0 600 Sek 10 90 C Para Parameterbezeichnung Beschreibung des Parameters Einstellungsbe bernom meter reich mener Wert EINSCHALTDIFFERENZ DER KOLLEKTOREN ODER DES FEST BRENNSTOFFKESSELS AUSSCHALTDIFFERENZ DER KOLLEKTOREN ODER DES FEST BRENNSTOFFKESSELS Wartungsanleitung Einstellung der Differenz zwischen der Kollektor bzw Festbrennstoffkessel Temperatur und Brauchwasser temperatur bzw Pufferspeichertemperatur bei der sich die Solarpumpe einschaltet Einstellung der Differenz zwischen der Kollektor bzw Festbrennstoffkessel Temperatur und Brauchwasser temperatur bzw Pufferspeichertemperatur bei der sich die Solarpumpe ausschaltet 112 Para Parameterbezeichnung
63. S GEWUNSCHTE RAUM TEMPERATUR BEI HEI ZUNGSABSCHALTUNG DARSTELL DER TEMPE RATURRUNDUNG AUTOMATISCHER UBER GANG DER UHR AUF SOMMER WINTERZEIT AUFZEICHNUNGSPERI ODE DER GEMESSENEN TEMPERATUR SIGNALTON FORTGESCHRITTENE DARSTELLUNG DER TEMPERATUREN Der Regler schaltet Heizung automatisch aus wenn die durchschnittliche Eintagestemperatur h her ist als die eingestellte Umschalttemperatur 0 NEIN 1 JA 30 10 Einstellung bedeutet durchschnittliche Ein Tages auften Temperatur bei der die Heizung automatisch abgeschaltet wird Einstellung des Au entemperaturwerts bei dem sich der Frostschutz einschaltet und der Kessel sich min destens auf die Minimaltemperatur erw rmt Anwahl der gew nschten Raumtemperatur wenn die Heizung ausgeschaltet ist Bestimmung der Darstellung der Temperaturrundung der gemessenen Temperatur Mit Hilfe des Kalenders schaltet der Regler automa tisch auf die Sommer und Winterzeit um Mit der Einstellung wird der Speicherzeitintervall der gemessenen Temperaturen bestimmt 0 NEIN 1 TASTATUR 2 FEHLER 3 TASTATUR amp FEHLER Mit der Einstellung wird festgelegt ob bei Tastendruck der Signalton aktiviert wird oder nicht Fortgeschrittene Darstellung bedeutet dass beim Durchbl ttern der Temperaturwerte die Ist und Soll Temperatur oder die ausgerechnete Temperatur angezeigt wird Einstellungen f r den ersten Heizkreis Para Parameterbezeich
64. SEL F r die Soll Temperatur des Fl ssigbrennstoffkessels wird die h chste unter den folgenden Temperaturen ber cksichtigt um den Parameterwert S5 3 erh hte ausgerechnete Temperatur des ersten Vorlaufs um den Parameterwert S5 4 erh hte ausgerechnete Temperatur des zweiten Vorlaufs um den Parameterwert S5 5 erh hte Soll Temperatur des Brauchwassers ausgerechnete Kesseltemperatur von den Reglern in der Bus Verbindung ausgerechnete Kesseltemperatur aufgrund der Einschaltung eines zus tzlichen Direktheizkreises Die Temperatur des Fl ssigbrennstoffkessels ist nach unten hin mit einer Minimaltempe ratur des Kessels Parameter P5 1 und nach oben hin mit einer Maximaltemperatur des Kessels Parameter S5 1 begrenzt Die Hysterese f r die Brennersteuerung ist mit dem Parameter S5 2 bestimmt Mit dem Parameter S5 2 kann man andere Brennersteuerungsarten ausw hlen und zwar S5 2 1 F r den Brennerausgangsbetrieb wird der Kesself hler nicht ber cksichtigt Der Brennerausgang schaltet AUS bei Kesselanforderung und umgekehrt S5 2 2 F r den Brennerausgangsbetrieb wird der Kesself hler nicht ber cksichtigt Der Brennerausgang schaltet EIN bei Kesselanforderung und umgekehrt Wartungsanleitung 132 Wenn kein Kesselbetrieb ben tigt wird betr gt die ausgerechnete Kesseltemperatur 4 C Der Befehl f r das Einschalten des Kessels mindestens auf Minimaltemperatur wird auch vom Frostschutz aktiviert und zwar
65. X COLLECTORS OR SOLID FUEL BOILER TEMPE RATURE MAX TEMPERATURE OF COLLECTORS OR SOLID FUEL BOILER COLLECTOR S FROST PROTECTION COLLECTOR S FROST PROTECTION TEMPE RATURE EMERGENCY SHUT DOWN TEMPERATURE FOR COLLECTORS OR SOLID FUEL BOILER Service settings for alternative ener By schemes with two heat sources it can be set if output or switchover between two heat sources is inverted n schemes with double fireplace boiler scheme 117 and 118 the flue gases sensor can be used to measure solid uel flue gases temperature parameter S1 4 9 In such cases the switchover from oil boiler to solid fuel boiler is activated also if flue gases temperature exceeds set point emperature Set also parameter S1 4 7 for sensor T1 or S1 5 10 for sensor T8 Setting of max flue gases temperature If flue gases emperature exceeds setted value controller indicates it Set also parameter 81 477 for sensor T1 or 81 5210 for sensor T8 Setting of min flue gasses temperature for solid fuel boiler above which the operation of liquid fuel boiler is disabled This option is used if the liquid and solid fuel boiler are connected on the same chimney pipe and is prohibited to have dual boiler operation Also set parameter 81 4210 for sensor T1 or 81 5213 for sensor 8 Setting of switch off difference between boiler and boiler return pipe temperature for boiler return pipe pump sources With this setting i
66. a Parameterbe Beschreibung des Parameters Einstellungs Ubernom meter zeichnung bereich mener Wert T8 FUHLERFUNK TION Die Einstellung erm glicht die Funktionsweise des F hlers T8 1 RF2 F hler der Raumtemperatur f r den zweiten Kreis 2 EF2 F hler zum Schutz der h chsten zul ssigen Tempera tur des Estrichs f r den zweiten Kreis Die h chste Tempera tur des Estrichs wird mit Parameter S3 11 eingestellt 3 RLF2 R cklauff hler des Mischkreises 2 Aktiviert wird die Begrenzung der h chsten erlaubten Differenz zwischen Vorlauf und R cklauf und somit das H chstleistungslimit des Heizkreises Die Differenz wird mit Parameter S3 14 eingestellt 4 RF1 Raumtemperaturf hler f r den ersten Heizkreiss 5 EF1 Sensor f r den Schutz der maximalen Temperatur des Estrichs f r den ersten Heizkreis Maximale erlaubte Tem peratur des Estrichs wird mit dem Parameter S2 11 gesetzt 6 RLF1 R cklauff hler vom ersten Mischheizkrei Aktiviert wird die Begrenzung der maximalen erlaubten Differenz zwischen den Vor und R cklauf und dadurch die Begrenzung der maximalen Leistung des Heizkreises Die Differenz setzt man mit dem Parameter 52 14 7 BF3 F hler der Brauchwasserzirkulation Der F hler wird am Austrittsrohr des Brauchwassers eingerichtet Erkennt der Regler einen pl tzlichen Temperaturanstieg wird die Umw lz pumpe zur Brauchwasserzirkulation eingeschaltet Laufzeit der Pumpe wird mit Parameter P4
67. ables the change of code which is necessary 0000 9999 THE SERVICE SETTINGS to unlock the service settings S and F parameters WARNING Keep new code on a safe place Without this 0001 code is impossible to change service settings TEMPERATURE SENSOR Selection of temperature sensors Pt1000 or KTY10 0 PT1000 TYPE 1 KTY10 T1 SENSOR FUNCTION Selection of function for sensor connected to input T1 1 RF1 1 RF room sensor in circuit 1 2 EF1 2 EF1 sensor for limitation of max floor temperature in 3 RLF1 circuit 1 Max floor temperature is set with parameter 2 11 4 BF3 3 RLF1 return pipe sensor in circuit 1 Activates limitation 5 SVS of difference between stand and return pipe and by thatthe 6 BF2 limitation of max heating circuit power Max difference is set 7 AGF with parameter 52 14 8 RFHP 4 BF3 d h w circulation with temperature sensor Sensoris 9 RLKF placed onto hot exit pipe from storage tank D h w circu 10 AGFTK lation pump is activated if temperature increase is detected Duration time of circulation is set with parameter P4 8 5 SVS d h w circulation with flow switch D h w circula tion pump is activated if contact are closed Duration time of circulation is set with parameter P4 8 6 BF2 auxiliary sensor in d h w storage tank It is installed in upper third of storage tank Warming of d h w will activate only when BF2 sensor detects drop of temperature 7 AGF
68. al function installed which enables simulations of all sensors With the help of this function user can test controller operation This function is intended for the cases of start up maintenance or testing of the controller Sensor simulation is activated in the following way First by pressing SD button select the screen with hydraulic scheme display Now press the SD button and hold it for 10 seconds The controller will switchover to the simulation mode Move between sensors by pressing the V button With buttons and set the tempera ture value for each selected sensor The simulated sensor mark will change from T to S Simulation operation mode is deactivated by pressing the SD button for 10 seconds or if no button is pressed for more than 5 minutes CONTROLLER FAILURE AND SERVICING In the event of failure or damage to the controller only the module shall be sent to service The base should stay mounted without disconnecting the cables Demount the controller in the following way Loosen the screw b and drag the controller module a towards yourself Now replace controller module or send it to the authorized service centre Before you start dismounting the controller make sure the main power sup ply switch is turned off Installation manual 74 Dimensions WX h x uuersseresneeensnnenerennn nennen 211 x 96 x 52 mm Controller weight sse 735 9 Body mater
69. alue You can change the settings by pressing the V button The setting value will begin to flash Now you can change it with buttons and Confirm the setting by pressing the V button Now you can move on to another parameter with buttons and and repeat the procedure Exit the parameter settings by pressing the button 35 Service setting manual 1 General settings meter setting AUT SWITCHOVER Automatic switch off and switch on of heating in respect to 0 NO AVERAGE OUTDOOR Setting of average one day outdoor temperature at which TEMP FOR SUMMER the heating should switch off or switch on 4 WINTER SWITCHOVER a OUTDOOR TEMP FOR Setting of outdoor temperature by which the frost protec 30 10 C ACTIVATION OF FROST _ tion will activate and run boiler at minimum temperature PROTECTION REQUESTED ROOM Setting of requested room temperature when heating is TEMP WHEN HEATING IS switched off SWITCHED OFF TEMPERATURE ROUND Precision of displayed temperatures UP AUT SHIFT OF CLOCK With the help of a calendar the controller carries outthe 0 NO TO SUMMER WINTER automatic clock changeover between summer and winter 1 YES TIME time P1 7 PERIOD OF TEMPERAT By setting this field you define how often the measured 1 30 min LOGGING temperatures are saved TONES By setting this field you define whether key pressing is 0 OFF accompanied with sound signals or not 1 KEYPAD 2 ERRORS
70. arkiert den Anschluss der offen in der Ausgangsposition des Umschaltventils ist EINSTELLUNG DER MINIMALE DREHZAHL DER PUMPE R9 Auf Grund der Fl che der integrierten Kollektoren muss der Nennfluss des Systems festgelegt werden der von 0 5 bis 1 2 I Min f r jeden Quadratmeter der Sonnenkollek toren betr gt bzw gem den Hinweisen der Herstellers Beispiel f r 3 Solarkollektoren mit einer Gesamtfl che von 6 m2 ist der Nennfluss im System 5 4 I Min beim gew hlten Durchfluss 0 9 I Min pro Quadratmeter des Kollektors Danach muss die Umlaufpumpe R9 manuell auf die maximale Drehzahl eingeschaltet werden siehe Kapitel Manueller Betrieb an Seite 103 Stellen Sie die Geschwindigkeit auf der Umlaufpumpe auf eine Stufe ein bei der die Pumpe den errechneten Nennfluss des Systems ein wenig berschreitet Stellen Sie mit dem Regelventil den Durchfluss im System so ein dass er dem errechneten Nennfluss entspricht Danach muss am Regler die Drehzahl der Pumpe auf 40 eingestellt werden und auch gepr ft werden ob der Schwimmer am Flussmessger t angehoben ist Wenn es im System keinen Durchfluss gibt dann stellen Sie am Regler die n chste Drehzahlstufe ein das sind 55 und pr fen erneut den Durchfluss Falls der Durchfluss noch immer nicht vorhanden ist muss am Regler die n chste Drehzahlstufe eingestellt werden also 70 und der Nennfluss des Systems vergr ert und der Vorgang wiederholt werden Falls beim Test die Anfangsstufe der Dreh
71. as the set day or night temperature for floor heating system Stand pipe sensor is not connected or has a failure The controller assumes a 120 C stand pipe temperature and deactivates room heating Heating can be reactivated only by manual operation mode Liquid fuel boiler sensor is not connected or has a failure The controller assumes a 85 C boiler temperature and activates the burner if heating is required The boiler temperature can be set manually on a boiler thermostat Solid fuel boiler sensor is not connected or has a failure The controller assumes a 85 C solid fuel boiler temperature Switchover valve turns to the solid fuel boiler Room sensor is not connected or has a failure Room heating operates uninterrupted according to the outdoor temperature Return pipe sensor is not connected or has a failure Room heating operates uninterrupted without influence of return pipe temperature The sensors of d h w storage tank are not connected or have a failure If one sensor has a failure the controller uses only the other sensor If both sensors have a failure the controller switches off the pump for d h w warming Solar collector sensor is not connected or has a failure The circulation pump for d h w warming with solar collectors is deactivated TABLE resistance of Pt1000 temperature sensors 20 gt 35 mE foo tar 145 155 o 100 5 1213 tn is 169 5 120 60 2
72. aste V fortsetzen Haben Sie versehentlich das falsche Schema ausgew hlt kehren Sie mit der Taste 9 zur Schema Auswahl zur ck Das ausgew hlte Hydraulikschema kann sp ter mit dem Wartungsparameter 51 1 ver ndert werden 3 SCHRITT EINSTELLUNG DER HEIZKURVENSTEILHEIT F R DEN ERSTEN KREIS Stellen Sie die Heizkurvensteilheit f r die Raumhei zung f r den ersten Heizkreis ein Te 20 Der Wert wird mit den Tasten und ver ndert Den eingestellten Wert best tigt man mit der Taste Der Regler verlangt eine Best tigung der Heizkur Mochten Sie wirklich veneinstellung mit der Taste fortsetzen Haben Sie versehentlich den falschen Heizkurven wert eingestellt kehren Sie mit der Taste SD zur erneuten Einstellung zur ck ver ndert werden Die Bedeutung der Heizkurvensteilheit ist im Detail auf Die eingestellte Heizkurvensteilheit kann sp ter mit dem Parameter P2 1 Detail auf Seite 110 beschrieben Bedienungsanleitung 84 4 SCHRITT EINSTELLUNG DER HEIZKURVENSTEILHEIT F R DEN ZWEITEN KREIS Stellen Sie die Heizkurvensteilheit f r die Raumhei zung f r den zweiten Heizkreis ein 21 2 0 Der Wert wird mit den Tasten und ver ndert Den eingestellten Wert bestatigt man mit der Taste Der Regler verlangt eine Best tigung der Heizkur Mochten Sie wirklich veneinstellung mit der Taste V fortsetzen Haben Sie versehentlich den falschen Heizkurven wert eingestellt kehren Sie mit der Taste 9 zur
73. ausgeschaltet Mit dem Parameter S2 4 und S3 4 k nnen andere Funk tionsm glichkeiten der Pumpe ausgew hlt werden Intensive BOOST Heizung Mit den Parametern P2 3 und P2 4 sowie P3 3 und P3 4 f r den zweiten Kreis wird die Dauer und die St rke der intensiven BOOST Heizung bestimmt die beim bergang des Zeitprogramms vom Nacht zum Tagesintervall aktiviert wird Mit der Einstellung der Boost Funktion verk rzen wir die ben tigte Zeit f rs erreichen der Soll Raumtemperatur beim Umschalten Vom Nacht auf das Tag Temperaturintervall Begrenzung AT beziehungsweise der Heizkreisleistung vom ersten Heizkreis Wenn Sie die h chste Heizkreisleistung begrenzen wollen benutzen sie den F hler T1 oder T8 zur Messung der R cklauftemperatur Die Parameter 81 423 oder 81 526 m ssen eingestellt werden Mit dem Parameter S2 14 stellt man die h chste zugelassene Differenz zwischen der Vorlauf und R cklauftemperatur ein Begrenzung AT beziehungsweise der Heizkreisleistung vom zweiten Heizkreis Wenn Sie die h chste Heizkreisleistung begrenzen wollen benutzen sie den F hler T8 zur Messung der R cklauftemperatur Der Parameter 81 523 muss eingestellt werden Mit dem Parameter S3 14 stellt man die h chste zugelassene Differenz zwischen der Vorlauf und R cklauftemperatur ein Begrenzung der R cklauftemperatur in den Kessel Auf den R cklauf in den Kessel wird der F hler T1 oder T8 montiert und die Parameter S1 4 9 und 81 5712 eingestellt Wen
74. ax 85 rH bei 25 C 20 C bis 65 C Relais Ausgang RO R1 R2 R4 R5 R6 R7 RB 4 1 A 230 V Triac Ausgang D op le 1 1 A 230 V Programmuhr DY 7 Tage Programmuhr Min Intervall nn 15 min Genauigkeit der eingebauten Uhr t 5 min Jahr Programmklasse ennt sect beasties de A Datenaufbewahrung ohne Stromversorgung min 10 Jahre Technische Charakteristiken F hler Temperaturf hlertyp A Pt1000 oder KTY10 F hlerwiderstand PETOO00 era 1078 Ohm bei 20 C 1900 Ohm bei 20 Verwendungstemperaturbereich Au enlufttemperaturf hler AF 25 65 C IP32 Tauchtemperaturf hler TF 25 150 C IP32 Anlegetemperaturf hler VF 0 85 C IP32 Rauchgastemperaturf hler CF 20 350 C IP32 Min Leiterquerschnitt f r F hler 0 3 mm2 Max Lange der Leiter f r F hler max 30 m Technischen Daten 152 CE KONFORMIT TSERKL RUNG Die Heizungsregler WXD entsprechen volgenden Richtlinien und Normen EU Niederspannungsrichtlinie LVD 2006 95 EC EU Richtlinie f r Elektromagnetische Vertr glichkeit EMC 2004 108 EEC EU Richtlinie Elektro und Elektro
75. befinden sich auf dem zweiten Men bildschirm BENUTZERPARAMETER Die Benutzerparameter sind in die Gruppen P1 allgemeine Einstellungen P2 Ein stellungen f r den ersten Heizkreis P3 Einstellungen f r den zweiten Heizkreis P4 Brauchwassereinstellungen P5 Kesseleinstellungen und P6 Einstellungen f r alternati ve Energiequellen eingeteilt Wenn im Men die gew nschte Parametergruppe ausgew hlt wird erscheint eine neue Anzeige Bezeichnung 34 1 Aktueller Parameterwert des Parameters Zuletzt best tigter Einstellwert Graphische Darstellung Werk tell rt der Einstellung erkseinstellungswe UMSCHALTUNG Beschreibung 0 NEIN des Parameters 1 JA Einstellbereich Aktueller Parameterwert Die Einstellung wird mit dem Dr cken der Taste V ver ndert Der Einstellwert f ngt an zu blinken und kann mit den Tasten und ver ndert werden Die Einstellung best tigt man mit der Taste Jetzt kann man sich mit den Tasten und zum anderen Parameter bewegen und das Verfahren wiederholen Die Parametereinstellungen verl sst man mit dem Dr cken der Taste SD 109 Wartungsanleitung Allgemeine Einstellungen Para Parameterbezeichnung Beschreibung des Parameters Einstellungsbe Ubernomme meter reich ner Wert AUTOMATISCHE SOM MER WINTER UMSCHAL TUNG DURCHSCHNITTSAUS SENTEMPERATUR FUR AUT SOMMER WINTER UMSCHALTUNG AUSSEN TEMPERATUR FUR EINSCHALTEN DES FROSTSCHUTZE
76. bernom ESTRICHTROCKNUNG 0 NEIN 1 KREIS 1 2 KREIS 2 3 KREIS 1 amp 2 NTERVALL 1 DAUER NTERVALL 1 START TEMPERATUR 0 60 C NTERVALL 1 END TEMPERATUR 10 60 C NTERVALL 2 START TEMPERATUR 10 60 10 60 NTERVALL 2 END TEMPERATUR 10 60 C 10 60 10 60 10 60 C 60 C 5 Tage NTERVALL 4 DAUER NTERVALL 4 START TEMPERATUR INTERVALL 4 END TEMPERATUR Estrichtrocknungsprofil Werkseinstellungen 20 20 INTERVALL 2 DAUER 1 15Tae 5 2 Ca 3 ELM E 50 20 D F1 2 5 F1 8 P 129 Wartungsanleitung 2 7 WERKSEINSTELLUNGEN Im Men befinden sich Softwarewerkzeuge f r ein leichteres Einstellen des Reglers Das Zur cksetzen auf die gew nschten Reglereinstellungen erfolgt mit der Auswahl von RESET RESET DER REGLERPARAMETER Setzt alle Parametereinstellungen P1 P2 P4 P5 P6 S1 au er 51 1 S2 S3 54 S5 56 und F auf die Werkseinstellungen zur ck RESET DER ZEITPROGRAMME L scht die eingestellten Zeitschaltprogramme und stellt die werkseingestellten Zeitschaltprogramme wieder her RESET RESET DES REGLERS UND NEUSTART DER ERSTEN EINSTELLUNG Setzt alle Parameter auf die Werkseinstellungen zur ck und startet die Reglereinstellung wie bei der Erstinbetriebnahme amp E B RESET G2 BENUTZEREINSTELLUNGEN SPEICHERN Speichert alle Reglereinstellungen als Sicherheitskopie BENUTZEREINSTELLUNGEN LADEN
77. ce This setting has affect only if S1 4 1 for sensor T1 or 81 524 for sensor T8 45 Service setting manual Para meter INFLUENCE OF DD2 ROOM SENSOR e m PUMP OPERATION MODE 2 5 6 7 MINIMUM STAND PIPE TEMPERATURE S S 2 52 MIXING VALVE CON STANT 52 9 MIXING VALVE CON STANT 2 10 MIXING VALVE D CON STANT MAX FLOOR TEMPE RATURE MINIMUM STAND PIPE TEMPERATURE IN COO LING MODE SHIFT OF TEMPERA TURE REQUIRED TO ACTIVATE STAND PIPE CONTROL N on a Service setting manual Setting of DD2 room sensor influence on the operation of first circuit 1 influence has only room unit DD2 controlling the first circuit coding switch on room unit S 2 OFF It can be set on first second or both room units 2 influence has only first room unit DD2 coding switch on room unit S 4 OFF 3 influence has only second room unit DD2 coding switch on room unit S 4 ON 5 room unit DD2 has no influence Setting of pump operation mode Settings have the following meaning 1 STAND circulation pump of mixing circuit regular 2 SWITCH 2 pump switches off if requested room temperature is OFF reached only direct circuit 3 operation according to time program P1 4 operation according to time program P2 5 SEL PROG operation according to selected time program Setting of minimum stand pipe temperature limitat
78. connection The lower limit of the liquid boiler temperature is the minimum boiler temperature param eter P5 1 and the upper limit is the maximum boiler temperature parameter S5 1 Burner hysteresis is set with parameter S5 2 Burner switches off when boiler temperature exceeds the calculated boiler temperature for more than 60 of the hyster esis and switches back on when boiler temperature drops below more than 40 96 of the hysteresis With parameter S5 2 you can select an alternative burner operation mode S5 2 1 operation of burner without boiler temperature sensor Burner output is activated when there is no need for heating Burner output is deactivated when there is need for heating S5 2 2 operation of burner without boiler temperature sensor Burner output is activated when there is need for heating Burner output is deactivated when there is no need for heating When there is no need for boiler operation the calculated boiler temperature is 4 C In the following cases the frost protection function can activate boiler if outdoor temperature drops below the frost protection temp parameter P1 3 if boiler temperature stand pipe temperature or room temperature drops below 4 C Service setting manual 56 Liquid fuel boiler protection If liquid boiler temperature drops below the minimum boiler temperature parameter P5 1 the mixing valve will gradually begin to close In case if liquid boiler temperature
79. cuit d h w storage tank solar collectors Erweiterungsschema Mischerheizkreis Brauchwassererw rmer Solarkollektoren 405 WXD10 WXD20 Oil boiler direct circuit d h w storage tank solar collectors Fl ssigbrennstoffkessel Direktheizkreis Brauchwassererw rmer Solarkollektoren 4 x N i Ott e 161 406 WXD10 WXD20 Oil boiler direct circuit d h w storage tank solar collectors Fl ssigbrennstoffkessel Direktheizkreis Brauchwassererw rmer Solarkollektoren aj N THER N 407 WXD10 WXD20 Oil boiler direct circuit mixing circuit d h w storage tank Fl ssigbrennstoffkessel Direktheizkreis Mischerheizkreis Brauchwassererw rmer oN e 162 407b WXD10 WXD20 Oil boiler direct circuit mixing circuit d h w storage tank solar collectors Fl ssigbrennstoffkessel Direktheizkreis Mischerheizkreis Brauchwassererwarmer Solarkollektoren T2 Lu
80. d return to the main menu Intensity of active display illumination Intensity of standby display illumination Contrast Select and confirm the requested setting with buttons and V Graphic symbol I Current setting value numeric Current setting value graphical Factory set value Setting range Current setting value You can change the setting with buttons and confirm it by pressing the V button Exit the setting by pressing the button Change of setting is stored only if confirmed with the V button Last confirmed setting value 33 User manual 4 Ti DATA OVERVIEW The following icons for accessing data on the controller operations are available in the menu Tilt zh S EP Mg G P User manual GRAPHIC DISPLAY OF OPERATING HOURS OF THE FIRST AND SECOND BURNER STAGE GRAPHIC DISPLAY OF DAILY TEMPERATURES FOR THE PERIOD OF PAST WEEK Graphic display of daily temperature course for each sensor Temperatures are recorded for the past week of operation DETAILED GRAPHIC DISPLAY OF TEMPERATURES FOR CURRENT DAY Detailed graphic display of temperature course in the current day for each sensor The fre quency of temperature recording can be set with parameter P1 7 OUTPUT OPERATION TIME COUNTERS Displayed are operation times of controller s outputs SPECIAL SERVICE DATA These serve to provide diagnostics for technical support Y
81. d with an innovative solution Easy start which ena bles the setup of controller in just three or four easy steps When the controller is connected to the power supply for the first time the display first shows the program version and company logo and then the first step of the procedure for controller settings is started STEP 1 LANGUAGE SETUP Use buttons and to select the requested language Confirm the selected language by pressing The controller requires confirmation of language Do you really want selection with the V button to continue In case you chose the wrong language return to the language selection with the button 9 User manual STEP 2 HYDRAULIC SCHEME SETUP Do vau really want to continue Select a hydraulic scheme for controller operation Move between schemes with buttons and Confirm the selected scheme by pressing All schemes with mixing heating circuit are available for radiators and floor wall heating The controller requires a confirmation of language selection with the V button In case you choose the wrong scheme return to scheme selection with the button GD Later you can change the selected hydraulic scheme with service parameter 51 1 3 SETUP HEATING CURVE STEEPNESS FOR THE FIRST CIRCUIT me 20 Do vau really wart to continue Set the heating curve steepness for the first heating circuit Change the value with butto
82. der Einstellung wird festgelegt um wie viel die Temperatur des Kessels erh ht sein soll als es f r die Temperatur der Brauchwasser gew nscht ist Mit der Einstellung wird festgelegt wann sich der Kessel mindestens auf die eingestellte Minimaltemperatur Erw rmt Funktion hat nur Einfluss bei Aktivem Heizen Mit der Einstellung wird die Selbstausschaltung des Brenners aktiviert wenn der Festbrennstoffkessel einge heizt wird Der Einstellungswert bedeutet die erforderte Erh hung der Temperatur des Festbrenstoffkessels der das Ausschalten des Brenners ausl st Observationsinter vall f r die Kesseltemperaturerh hung ist 2 min Eingestellt wird die obere Arbeitstemperatur des Festbren stoffkessel berschreitet der Kessel diesen Wert beginnt der Regler selbst ndig die errechnete Temperatur f r den Mischheizkreis 1 und 2 zu erh hen Eingestellt wird die maximal zul ssige Temperatur des Festbrenstoffkessels oder W rmespeicher Wird die Temperatur berschritten aktiviert sich eine Zwangsent nahme der W rme im Brauchwassererw rmer und des Heitzsystems Dabei hat noch immer der Schutz der maximalen Temperaturzufuhr f r Mischheizkreise Einfluss Mit der Einstellung bestimmen wir die minimal zul ssige R cklauftemperatur in den Kessel bei klassischen oder Hochtemperatur Kesseln Die Einstellung gilt nur bei Hydraulik Schemata die die Begrenzung der R cklauftemperatur erm glichen Erforderlich ist die Ausf hrung der
83. des Fl ssigbrennstoffkessels aus und schaltet sie mit der Taste V ein oder aus Die Einstellung verl sst man mit dem Dr cken der Taste SD Bedienungsanleitung 100 e t Inbetriebnahme des Festbrennstoffkessels Diese Funktion schaltet den Fl ssigbrennstoffkessel aus und kann dann verwendet wer den wenn der Festbrennstoffkessel eingeheizt werden soll Wenn der Festbrennstoffkes sel die erforderliche Heiztemperatur in einem bestimmten Zeitraum nicht erreicht schaltet sich erneut der Fl ssigbrennstoffkessel ein Mit den Tasten und w hlt man die Funkti on Inbetriebnahme des Festbrennstoffkessels aus und aktiviert sie mit der Taste V Die Einstellung verl sst man mit dem Dr cken der Taste 5 Alle Benutzerfunktionen k nnen jederzeit unterbrochen werden indem die Ikone ausgew hlt wird 101 Bedienungsanleitung BETRIEBSARTENWAHL Im Men w hlt man die gew nschte Reglerbetriebsart separat f r jeden Heizkreis und die Brauchwassererw rmung aus Im Men kann die Betriebsart f r folgendes ausgew hlt werden 1 eese 2 e Perd ZA Erster Heizkreis Zweiter Heizkreis Brauchwasser Manueller Betrieb Umschaltung zwischen Heizung und Kuhlung Messungen der Emmisionen Di m 4 a m D o gt a c a 2 m 2 n 4 m z c z D N m m z I m N a m n Ei Betrieb nach ausgew hltem Zeitprogramm Betrieb l uft nach dem ausgew hlten Ze
84. des Heizregler Projekt muss auf Berechnungen basieren und geplant sein Das Berechnen und Planen liegt ausschlie lich in Ihren H nden und muss den geltenden Regeln entsprechen Zeichnungen und Texte in der vorliegen den Anleitung dienen lediglich als Beispiel deshalb bernimmt der Heraus geber keine Haftung f r sie Eine Haftung des Herausgebers f r unsachge m e und falsche oder fehlerhafte Interpretation der Daten und die daraus resultierenden Sch den sind ausdr cklich ausgeschlossen Wir behalten uns das Recht auf technische Fehler und nderungen ohne vorherige Ank ndi gung vor Der Anschluss der Regler darf nur vom qualifizierten Fachpersonal oder einem bevoll machtigten Industriebetrieb durchgef hrt werden Bevor in die Verdrahtung gegriffen wird sicherstellen dass der Hauptschalter ausgeschaltet ist Beachten Sie die Vorschriften f r Niederspannungsinstallationen IEC 60364 und VDE 0100 sowie gesetzliche Regeln und Vorschriften zur Verh tung vor Berufsunf llen gesetzliche Vorschriften zum Umweltschutz und sonstige nationalen Vorschriften Bevor Sie das Geh use ffnen jedes Mal pr fen ob die Stromversorgung aller Pole unter brochen ist Das Nichtbeachten der Anweisungen kann ernsthafte Personensch den wie zum Beispiel Verbrennungen zu Folge haben und kann lebensgef hrlich sein Der Regler muss ber einen Trennstecker allpolig angeschlossen werden Die Entfernung der Pole bei einem ge ffneten Stecker muss minde
85. die eingeschr nkte bivalente Betriebsart eingeschaltet Das wiederum bedeutet dass die alternative Quelle mit Verz gerung eingeschaltet werden kann Die Verz gerungszeit h ngt vom Temperaturdefizit und der Parametereinstellung S5 15 ab Mit dem Parameter S6 19 wird die Au entemperatur der monovalenten Betriebsart be stimmt Das hei t die alternative W rmequelle kann nicht eingeschaltet werden wenn die Au entemperatur h her als der eingestellte Wert ist Wartungsanleitung 134 KESSELBEIMISCHPUMPE BYPASS Diese M glichkeit steht zu Verf gung bei klassischen l und Festbrennstoff Kesseln die nicht an einen Speicher angeschlossen sind Der Ausgang der RO oder R9 kann f r die Steuerung der Bypass Pumpe zur Anhebung der R cklauftemperatur des Kessels verwen det werden Diese Betriebsart wird mit der Einstellung des Parameters S1 11 4 f r RO oder S1 12 5 f r R9 ausgew hlt Der T1 oder T8 F hler wird am R cklauf in den Kessel vor dem Beimischpunkt eingebaut und der Parameter S1 4 9 f r T1 oder S1 5 12 f r T8 muss eingegeben sein Wenn die R cklauftemperatur niedriger ist als eingestellt mit dem Parameter S5 14 schaltet sich die Pumpe ein BRAUCHWASSER Brauchwassererw rmung mit Fl ssigbrennstoffkessel Mit dem Parameter P4 1 kann die Soll Temperatur des Brauchwassers f r das Zeitintervall in dem die Brauchwassererw rmung ausgeschaltet ist eingestellt werden Wenn die Kesseltemperatur die h chste zugelassene
86. draulic system with boiler bypass pump In case of system with boler bypass pump set parameter S1 11 4 for output RO or S4 9 4 for output R9 13 AGFTK flue gases sensor for solid fuel boiler Controller blocks liquid fuel boiler operation if flue gases exceed tempe rature setted with parameter 5 19 43 Service setting manual Para Parameter name Parameter description Setting Default meter range setting DIGITAL INPUT T1 T6 T8 This setting defines controller operation mode if short circuit is detected on input T1 T6 or T8 1 Day temperature operation mode regardless to currently 2 DIR CIRC selected operation mode See also parameter 51 9 DELAYED 2 Additional direct circuit is connected Temperature requi SWITCHO rements of additional direct circuit P3 5 and P3 6 are also VER considered for calculation of requested boiler temperature 3 DIR By schemes with two heat sources the switchover to other CIRCUIT heat source is done with delay set with parameter 55 15 4 COOLING 3 Additional direct circuit is connected Temperature requi 5 BOOST rements of additional direct circuit P3 5 and P3 6 are also considered for calculation of requested boiler temperature By LOCKOUT schemes with two heat sources the switchover to other heat 7 BURNER source is done without delay 4 Switchover from heating to cooling operation mode 5 Boost heating function is activated This setting disables regular boost
87. ds the maximum boiler temperature parameter S5 1 the d h w will be warmed up to the maximum temperature set with parameter S4 3 D h w warming pump is switched off with delay The delay time is set with parameter 4 12 Service setting manual 58 D h w warming with solid fuel boiler When a solid fuel boiler is in operation the d h w is warmed to the required temperature parameter S4 10 independent of the time program If solid fuel boiler temperature exceeds the maximum boiler temperature parameter 5 13 the maximum allowed d h w temperature parameter S4 3 is set for required d h w temperature D h w warming in storage tank with integrated heat pump In this case a special operation mode of d h w control is activated by setting the param eter S1 4 8 for sensor T1 or 81 5211 for sensor T8 Install a room sensor in the room where the heat pump is located and connect it to the T1 or T8 terminals Controller will block the d h w warming with boiler if the heat pump room temperature is higher as set with parameter S4 11 D h w warming with solar collectors The basic operation of the solar collectors system is determined by switch on difference switch off difference and minimum temperature of solar collectors parameters P6 1 P6 2 and P6 3 D h w is warmed up to the requested temperature set with parameter S4 10 If d h w is warmed and the temperature of solar collectors exceeds the maxim
88. e has only second room unit DD2 coding switch on room unit S 4 ON 5 room unit DD2 has no influence PUMP OPERATION Setting of pump operation mode Settings have the following 1 STAN MODE meaning DARD 1 STAND circulation pump of mixing circuit regular 2 SWITCH 2 pump switches off if requested room temperature is reached OFF only direct circuit 3 PROG 3 operation according to time program P1 P1 4 operation according to time program P2 4 PROG 5 SEL PROG operation according to selected time program P2 5 SE LECTED MINIMUM STAND PIPE Setting of minimum stand pipe temperature limitation when 10 90 C TEMPERATURE heating is active 47 TO Service setting manual setting manual meter range setting TEMPERATURE 85 radiat Ee Se 06 XING VALVE CONTROL mixing valve control is in stand by HEC Setting of mixing valve position correction intensity Smaller 0 5 2 0 EN CONSTANT value means shorter movements higher value means longer mixing valve movements MIXING VALVE I CON Setting of mixing valve control frequency how often mixing 2 5 STANT valve position is being controlled Smaller value means low frequency higher value means higher frequency of mixing valve corrections MIXING VALVE D Sensitivity of mixing valve for stand pipe temperature changes CONSTANT Smaller value means low sensitivity higher value means high sensitivity MAX FLOOR TEMPE Setting of maximum floor tempe
89. eating curve or calculated 15 15 C HEATING CURVE stand pipe temperature Use this setting to eliminate deviation between actual and required room temperature DURATION OF BOOST Duration of boosted room temperature by changeover 0 200 min HEATING from night to day heating period ROOM TEMPERATURE Boost room temperature increase by changeover from INCREASE BY BOOST night to day heating period HEATING HEAT CURVE STEEP Setting of heat curve steepness for additional direct NESS FOR ADDITIONAL heating circuits DIRECT CIRCUITS PARALLEL SHIFT OF Parallel shift of heating curve for additional heating 15 15 C HEATING CURVE FOR circuits 16 90 C ADD DIRECT CIRCUITS Values 16 90 set directly the boiler temperature when additional direct heating circuit is activated Settings for domestic hot water Parameter name Parameter description Setting range Default meter setting D H W TEMPERATURE Setting of d h w temperature in OFF program timer 4 70 C IN OFF PERIOD interval PRIORITY OF D H W Setting if d h w heating has priority to room heating in 0 NO WARMING TO CIRCUIT 1 circuit 1 1 YES PRIORITY OF D H W Setting if d h w heating has priority to room heating in 0 NO WARMING TO CIRCUIT 2 circuit 2 1 YES TIME PROGRAM FOR D Selection of d h w warming time program which willbe 1 PROG 1 H E H W CIRCULATION used for d h w circulation 2 PROG 2 Setting 1 is first time program fo
90. ed parameter group anew screen appears Parameter is locked Parameter mark BEE 2 pf IM Parameter value MIN 401 423h Settings range Factory set value of DEF 401 S the parameter HYDRAULIC SCHEME Parameter description You can change the setting by pressing the V button Parameters are locked by default A new screen appears for the entry of unlocking code Use buttons and to find the number you wish to change and press the V button 0 0 0 0 When the number begins to flash you can change it with buttons and and confirm it by pressing the V but ton When the correct code is entered the controller will unlock the parameters and return to the menu with the selected group of parameters Exit the unlocking code entry by pressing the 2 button The factory set code is 0001 You can change the parameter value with buttons and Confirm the selection by pressing the V button Now you can move on to another parameter with buttons and and repeat the procedure Exit parameter settings by pressing the Z3 button Only a trained professional shall perform the changing of service and func tion parameters 41 Service setting manual i 1 General service settings meter range setting S11 HYDRAULIC SCHEME Selection of hydraulic scheme depends E on type of 1 controller CODE FOR UNLOCKING This setting en
91. ed technician or an authorised organisation Prior to any intervention into the wiring make sure that the main switch is switched off Low voltage installation regulations IEC 60364 and VDE 0100 statutory provi sions for accident prevention statutory provisions for environmental protection and other national rules shall be observed Before you open the housing make sure that all poles of electrical supply had been dis connected Failure to follow these instructions can lead to serious injuries such as burns or even threat to human life The controller must be connected via switch for all poles Spacing at switch s open con tacts shall be at least 3 mm All low voltage connections such as connections of temperature sensors must be placed separately from power supply connections All temperature sensor connections shall be placed into the left field and all power supply connections shall be placed in the right field of the controller The relay R9 is designed as semi conductor relays for pump speed con trol If n TERN Dt TI ol L m le AB OND R8 1 lo e 5 lt cim Oe be Oe Ces R N 7m AB uo o oli Ms oja DI AS 4 9 BUS cL mr 69 Installation manual CONNECTION OF TEMPERATURE SENSORS Immersion sensor Immersion sensor is intended to be installed in
92. egler WXD10B WXD10 WXD20 Ms E TRI 22 0 CE anbe el e 12 29 MON 3 2 2002 DA MM om EINLEITUNG WXD sind moderne mikroprozessorgesteuerte Ger te hergestellt in digitaler SMT Tech nologie Witterungsgef hrte WXD Regler dienen der Regulierung des Direkt und oder Mischerheiz kreises oder zweier Mischerheizkreise und der Brauchwassererw rmung mittels Kessel Sonnenkollektoren und anderer Energiequellen GD F r die Erstinbetriebnahme des Reglers Siehe Seite 83 79 INHALT EINIGUNG E 79 BEDIENUNGSANLEITUNG Beschreibung des Reglers ceci sn coaches een tt Dea nau then E na iban drain 82 Reglereinstellung bei der Erstnbetrtebnabme nn nnen nenne ernennen nenn 83 Tastatur und sonstige Tasten i tenete rennes 86 Graphisches LED DISplay nennen enne nns 87 Beschreibung und Aussehen der HauptanZeige 87 Beschreibung der angezeigten Symbole am Display 88 ele Ee e EE E 88 Symbole f r Darstellung der Betriebsart rennen nennen een 88 Symbole der Benutzerfunktionen essere 88 Symbole zur Darstellung der Temperaturen und anderer Daten 89 Symbole der Gchutztunkttonen rennes 91 Symbole der Kommunikation zwischen angeschlossenen Ger ten 91 Symbole f r Warnungen und Meldungen 92 Bildschirm f r hilfe Meldu
93. eis 2 Zweiter Heizkreis Brauchwasser F r jeden Heizkreis stehen zwei Zeitprogramme zur Verf gung 1 Erstes Zeitprogramm 2 Zweites Zeitprogramm nderungen im Zeitprogramm Mit den Tasten und V w hlt man den gew nschten Heizkreis und anschlie end das gew nschte Zeitprogramm aus Eine neue Anzeige erscheint Nummer des Zeitprogramms und des Heizkreises Der gew hlte Tag Zeitlinie Das Zeitprogramm f r den jeweiligen Tag wird angezeigt Zeitprogramm kopieren Zeitprogramm einstellen Mit den Tasten und Y wird der Tag an dem die Ver nderung im Zeitprogramm stattfinden soll ausgew hlt oder der Tag in andere Wochentage kopiert Jetzt mit den Tas ten und V die Ikone f r das Einstellen oder die Ikone f r das Kopieren des Zeitprogramms ausw hlen Bedienungsanleitung 104 Zeitprogramm einstellen Eine neue Anzeige mit dem Zeitprogramm und drei Ikonen f r die nderung des Programms erscheint LLL Ba Kursor bewegt sich frei 0 4 12 16 20 24 9 00 00 DE A 0FF Zeichnen des Ausschaltintervalls oder el SS Nachttemperatur Zeichnen des Einschaltintervalls oder Tagestemperatur Mit den Tasten und wird die gew nschte Befehlsikone ausgew hlt und mit der Taste wird sie best tigt Auf der Zeitlinie erscheint ein Kursor Jetzt zeichnet man mit den Tasten und den gew nschten Zeitintervallverlauf Das Zeichnen des Intervalls
94. eitweise unter den Gefrier punk f llt geeignet Einstellung der Temperatur bei welcher sich der Kollektoren Frostschutz aktivieren soll 1 GLEICH ZEITIG 0 600 MIN VERZ G EINSCH DES FL SSIG BRENNSTOFF KESSELS Mit der Einstellung wird festgelegt ob das heizen mi dem Fl ssigbrennstoffkessel mit den Kollektoren oder Festbrennstoffkessel gleichzeitig arbeitet oder nur mit Verz gerung wenn das heizen mit Kollektoren oder Festbrenstoff pausiert 120 1 BRAUCH WASSER 2 HEIZKREIS 3 BEIDES Mit der Einstellung legen wir fest welche Heizkrei e schalten den Kessel mit Verz gerung nach dem Betrieb des Solarsystems 1 Brauchwasser 2 Heizkrei e 3 Brauchwasser und Heizkrei e Mit der Einstellung wird das kurzzeitige Einschalten der Solarpumpe erm glicht So erf hrt man die aktuelle Temperatur der Kollektoren Diese M glichkeit wird angewendet wenn der Temperaturf hler nicht direkt im Kollektor platziert ist Mit der Einstellung wird bestimmt ob und wie die Begren zung der minimalen Kollektortemperatur und Festbrenn stoffkesseltemperatur ber cksichtigt wird 0 ON OFF 1 RPM Mit der Eistellung wird bestimmt ob die Pumpe in on oder off Modus oder mit RPM Drehzahlregelung betrie ben wird Die Pumpendrehzahlregelung erfolgt in 5 Stufen 40 95 55 9o 70 85 100 der Drehzahl Eingestellt wird die minimale Stufe der RPM Modulation f r die Pumpe 1 40 der Drehzahl 2 55 der
95. emperature changes While the outdoor temperature is above 5 C you can adjust the room temperature by changing the day or night temperature or with the parallel shift of the heating curve param eters P2 2 and P3 2 If the object is underheated by low outdoor temperatures the heat curve steepness needs to be increased If the object is overheated by low outdoor temperatures the heat curve steepness needs to be decreased The maximum steepness increase decrease should not be greater than 0 1 to 0 2 units per one observation At least 24 hours must pass between two observations Preferred settings of the heating curve steepness Heating system Setting range With adjusting the heat curve steepness the controller is tuned with the building For optimal controller operation the right setting of the heat curve steepness is very important 39 Service setting manual Heat curve diagram Tv C Stand pipe temperature Outdoor temperature Service setting manual 40 SERVICE PARAMETERS Service parameters are divided into the following groups S1 general settings S2 set tings for the first heating circuit S3 settings for the second heating circuit S4 settings for domestic hot water S5 settings for boilers in S6 settings for alternative energy sources Service parameters enable you to choose among various additional functions and adapta tions of controller s operation When you select the request
96. emperature due to priori ty of d h w warming ED Circulation pump in direct heating circuit is switched off in scope of SET ED control Limitation of stand pipe temperature due to exceeded maximum floor temperature Limitation of stand pipe temperature due to exceeded maximum 4 11 temperature difference between stand and return pipe i e exceeded maximum power of heating circuit A8 Limitation of stand pipe temperature due to unsurpassed minimum boiler temperature 8 Rise of stand pipe temperature due to the exceeded protection tem perature of heat source ig Limitation of stand pipe temperature due to the unsurpassed heat source return pipe temperature Counter of total operating hours and fuel consumption for burner on 1st stage Counter of total operating hours and fuel consumption for burner on 2nd stage SYMBOLS FOR PROTECTION FUNCTIONS Liquid fuel boiler overheating protection Solid fuel boiler overheating protection Solar collectors overheating protection un User manual manual Accumulator overheating protection D h w storage tank overheating protection D h w storage tank overheating protection cooling directed into the boiler d D h w storage tank overheating protection cooling directed into the collectors Frost protection heating circuit e Frost protection boiler switch on to minimum temperature Burner interface or Junkers Vaillant inteface is connected Room unit DD2
97. ennstoffkessel 2x Mischerheizkreis Brauchwassererw rmer T2 THOR nm e e 423b WXD20 Liquid fuel boiler heat accumulator with a built in d h w storage tank 2x mixing circuit Fl ssigbrennstoffkessel W rmespeicher mit eingebauten Brauchwassererw rmer 2x Mischerheizkreis 177 423c WXD20 Gas boiler heat accumulator with a built in d h w storage tank 2x mixing circuit Gaskessel Warmespeicher mit eingebauten Brauchwassererwarmer 2x Mischerheizkreis 4 N Lu INS e 4234 WXD20 Expansion scheme heat accumulator with a built in d h w storage tank 2x mixing circuit Erweiterungsschema Warmespeicher mit eingebauten Brauchwassererwarmer 2x Mischerheizkreis 178 423e WXD20 Heat accumulator 2x mixing circuit d h w storage tank Warmespeicher 2x Mischerheizkreis Brauchwassererwarmer u 4 N mo HORA E INS D 3 GND Kegel T3 Ede 423f WXD20 Solid fuel boiler 2x mixing circuit d h w storage tank Festbrennstoffkessel 2x Mischerheizkreis Brauchwassererw rmer T2 179 423g WXD20 Combined solid fuel oil boiler 2x mixing circuit d h w storage tank Kombike
98. er between day and night temperature or activation and deactivation of domestic hot water warming First heating circuit gt Second heating circuit Domestic hot water For each heating circuit there are two time programs available 91 First time program 02 Second time program Modifying the time program Select the requested heating circuit and time program with buttons and Anew screen will appear Time program and heating circuit number Selected day Timeline display of time program for the selected day Time program copying Time program editing Select the day which you wish to edit or copy with buttons and V Now use buttons and V to select the icon for time program management or the icon for time program copying ee User manual 30 Time program editing new screen appears with the display of time program and three icons for editing the program free movement of the cursor drawing of switch off interval or night temperature drawing of switch on interval or day temperature Select the requested command icon with buttons and confirm the selection by pressing the button Cursor will appear on the time line Now draw the requested time interval course with buttons and Finish drawing of time program by pressing the button Exit the time program editing by pressing the button Time program copying Anew screen appear
99. era nachkorrigiert werden en gemessenen Tempera nachkorrigiert werden en gemessenen Tempera nachkorrigiert werden en gemessenen Tempera nachkorrigiert werden en gemessenen Tempera nachkorrigiert werden en gemessenen Tempera nachkorrigiert werden en gemessenen Tempera nachkorrigiert werden Wartungseinstellungen f r den ersten Heizkreis bernom 1 2 KF2 3 ZIRKULA TION 4 EL HEIZ K RPER 5 BYPASS PUMPE 6 HAUPT PUMPE 7 W RME PUMPE mener Wert I GEN aaa BEE EN Be nl Kess AUSWIRKUNG DER ABWEICHUNG DER RAUMTEMPERATUR T1 ODER T8 RAUM F HLEREINFLUSS Einstellen der Auswirkung der Raumtemperaturabweichung 0 0 3 0 auf die errechnete Vorlauftemperatur Niedrige Werte bedeuten eine Kleinere Auswirkungen und h here Werte st rkere Auswirkungen auf den Regler Mit der Einstellung bestimmen wir ob der Raumf hler T1 oder T8 auf die Funktionsweise des ersten Heizkreiss hat 1 Automatik betrieb bedeutet das der Raumf hler Einfluss hat wenn die Raumeinheit DD2 nicht angeschlossen ist Der Raumf hler keinen Einfluss hat wenn die Raumeinheit DD2 angeschlossen ist 2 der Raumf hler hat Einfluss 3 der Raumf hler hat keinen Einfluss Diese Funktion hat nur Bedeutung wenn der Parameter S1 4 1 F hler T1 oder S1 5 4 F hler T8 ausgew hlt ist 119 Wartungsanleitung Para Parameterbezeich Beschreibun
100. eratur berschreitet 117 1 RF2 2 EF2 3 RLF2 4 RF1 5 EF1 6 RLF1 7 BF3 8 SVS 9 BF2 10 AGF 11 RFHP 12 RLKF 13 AGFTK Wartungsanleitung Para meter Wartungsanleitung DIGITALEINGANG T1 T6 T8 ANTIBLOCKIER FUNKTION FERNSCHALTUNG BEI BUS VERBIN DUNGEN AUSWAHL DER KREISE ZUR FERN SCHALTUNG HEIZOBJEKTTYP ZEIT KONSTANTE FUNKTION DES AUSGANGS R0 Die Einstellung bestimmt die Funktionsweise des Reglers wenn es im Eingang T1 T6 oder T8 zum Kurzschluss kommt 1 Ferneinschaltung bedeutet Betriebsart mit der gew nsch ten Tagestemperatur unabh ngig von der momentan ausge w hlten Art der Regler Funktion Siehe auch 51 9 2 Zus tzlicher Direkt Heizkreis bedeutet dass zur Errech nung der erforderlichen Kesseltemperatur die F rderung des zus tzlichen Direktkreises wie im Parameter P3 5 und P3 6 eingestellt ber cksichtigt wird Bei Schemen mit zwei Heiz quellen wird die Umschaltung auf die Kontrollierte Heizquelle mit Verz gerung hinsichtlich der Parametereinstellungen von 5 15 vorgenommen 3 Gleich wie 2 wobei der Kessel sofort aktiviert wird ohne Verz gerung 4 Regulationsfunktionsweise schaltet auf K hlung um 5 Aktiviert die Heizung Boost Funktion Wobei diese nicht Aktiviert wird bei der Umschaltung von Nacht auf Tagtem peratur 6 Fl ssigbrennstoffkessel wird ausgeschaltet und auf Festbrenstoff Kessel Heizen gewartet 7 Brennerbetriebsstundenz hlung
101. ergy sources SWITCH ON DIFFE Setting of difference between solar collectors or solid fuel RENCE FOR COLLEC boiler temperature and storage tank or heat accumulator TORS OR SOLID FUEL temperature by which the circulation pump shall switch on BOILER TORS OR SOILD FUEL temperature by which the circulation pump shall switch off BOILER MIN TEMPERATURE Setting of min solar collector or solid fuel boiler temperature OF COLLECTORS OR to activate the circulation pump SOLID FUEL BOILER SWITCH OFF DIFFE Setting of difference between solar collectors or solid fuel RENCE FOR COLLEC boiler temperature and storage tank or heat accumulator Service setting manual 38 HEATING CURVE With adjustion of heating curve the controller is adapted to the building Proper heating curve adjustion is very important for optimal heating control Heating curve steepness indicates what temperature is required for the heating bodies by a determined outdoor temperature The steepness value depends mainly on the heating system type floor wall radiator convector heating and insulation of the building Determining the heating curve steepness If you have enough data you can determine the heating curve steepness with a calcula tion otherwise from experience based on the evaluation of heating system dimensioning and building insulation The heating curve steepness is set correct ifthe room temperature remains stable even by large outdoor t
102. es Festbrennstoffkessels Wenn die Temperatur des Festbrennstoffkessels unter die Minimaltemperatur Parameter P5 2 sinkt fangt das Mischventil an sich stufenweise zu schlieRen Im Falle dass die Kesseltemperatur die optimale Arbeitstemperatur Uberschreitet wird die ausgerechnete Vorlauftemperatur vom Regler verh ltnism ig angehoben Auf diese Weise wird verhindert dass der Kessel sich berhitzt und der W rme ber schuss wird in das Objekt abgeleitet Wenn die Temperatur des Festbrennstoffkessels trotzdem die Maximaltemperatur des Kessels Parameter S5 13 berschreitet ffnet sich das Mischventil stufenweise bis zur Vorlauf Maximaltemperatur Parameter S2 6 und S3 6 Auch die Brauchwasserpumpe wird eingeschaltet Der Schutz schaltet sich aus wenn die Kesseltemperatur unter die Maximaltemperatur sinkt 133 Wartungsanleitung W RMESPEICHER Schutz des W rmespeichers Wenn die W rmespeicher Temperatur unter die eingestellte Minimaltemperatur des Spei chers Parameter P5 3 sinkt wird das Mischventil stufenweise geschlossen Im Falle dass die W rmespeicher Temperatur die Maximaltemperatur des Speichers Parameter 55 13 berschreitet aktiviert sich der Speicherschutz der das Mischventil h chstens bis zur h chsten Vorlauftemperatur Parameter S2 6 und S3 6 ffnet Auch die Brauchwasserpumpe wird eingeschaltet Der Schutz schaltet sich aus wenn die Tempera tur des Speichers unter die Maximaltemperatur sink
103. es gew nschten Hydraulikschemas Vom Regler MA Typ abhangig ENTSPERRKODE _ Die Einstellung erm glicht eine Ver nderung des Kodes 0000 9999 F R AUFSCHLIES notwendig f r die Aufschlie ung der Wartungseinstellungen SUNG DER S und F Parameter WARTUNGSEIN ACHTUNG Den neuen Kode sorgf ltig aufbewahren da STELLUNGEN ohne den Kode keine Ver nderung der Wartungseinstellun gen m glich ist TEMPERATURF H Den Temperaturf hlertyp Pt1000 oder KTY10 anw hlen 0 PT1000 LERTYP 1 KTY10 1 F HLERFUNK Mit der Funktion w hlt man die Betriebsart des F hlers T1 1 RF1 TION 1 RF1 Raumtemperaturf hler f r den ersten Kreis 2 EF1 2 EF1 F hler zum Schutz der h chsten zul ssigen Tempera 3 RLF1 tur des Estrichs f r den ersten Kreis Die h chste Temperatur 4 BF3 des Estrichs wird mit Parameter S2 11 eingestellt 5 SVS 3 RLF1 R cklauff hler des Mischkreises 1 Aktiviert wird 6 BF2 die Begrenzung der h chsten erlaubten Differenz zwischen 7 AGF Vorlauf und R cklauf und somit das H chstleistungslimit des 8 RFHP Heizkreises Die Differenz wird mit Parameter S2 14 eingest 9 RLKF ellt 10 AGFTK 4 BF3 F hler der Brauchwasserzirkulation Der F hler wird am Austrittsrohr des Brauchwassers eingerichtet Erkennt der Regler einen pl tzlichen Temperaturanstieg wird die Umw lz pumpe zur Brauchwasserzirkulation eingeschaltet Laufzeit der Pumpe wird mit Parameter P4 8 eingestellt 5 SVS an Eingang T1 wird
104. exceeds the maximum boiler temperature parameter S5 1 boiler protection is activated At this point the maximum boiler temperature parameters S2 6 and S3 6 is set for the calculated stand pipe temperature The d h w warming pump is also activated The pro tection is deactivated when boiler temperature drops below the maximum boiler tempera ture Control of a two stage burner To control the two stage burner set the parameter S1 11 1 The first stage of the burner is controlled by relay R1 and the second stage is controlled by relay RO The second stage is switched on when boiler temperature drops 4 C below the switch on temperature for the first stage or if boiler temperature remains below the switch on tem perature for the first stage for more than 15 minutes The second stage is switched off when the temperature in the boiler is less than 4 C below the switch off temperature for the first stage SOLID FUEL BOILER Solid fuel boiler protection If solid boiler temperature drops below the minimum temperature parameter P5 2 the mixing valve will gradually begin to close In case if solid boiler temperature exceeds the optimal operation temperature the controller proportionally increases the calculated stand pipe temperature In such way boiler overheating is prevented and the surplus heat is dissipated into the building If solid fuel boiler temperature exceeds the maximum boiler temperature parameter 5 13 the mixing
105. firm it with the V button Exit the setting by pressing SD 25 User manual Y E USER FUNCTIONS User functions enable additional comfort and benefits of using the controller The following user functions are available in the menu First heating circuit Second heating circuit Domestic hot water Energy sources USER FUNCTIONS FOR THE FIRST AND SECOND HEATING CIRCUIT i PARTY operation mode PARTY function activates operation according to the requested comfort temperature Select Party function with buttons and and activate it with the V button To set the expiration time and requested temperature select the Y _ icon again Now use the and buttons to select the setting you wish to change and press the button The value will begin to flash Change the value with buttons and and confirm it by pressing the V button Exit the setting by pressing the button C0 ECO operation mode ECO function activates operation according to the requested saving temperature Select Eco function with buttons and and activate it with the button To set the expiration time and requested temperature select the icon again Now use the and buttons to select the setting you wish to change and press the button The value will begin to flash Change the value with buttons and confirm it by pressing the V button Exit the setting by pressing the button Funct
106. flue gas temperature sensor for boiler Warning is displayed on the screen if flue gas temperature rises above value of parameter 5 18 8 RFHP room sensor in ambient where d h w heat pump is installed D h w warming with other heat sources is disabled if room temperature is higher as set with parameter S4 11 9 RLKF boiler return pipe sensor Controller maintains min level of boiler return pipe temperature set with parameter 5 14 For this setting it is necessary to have a hydraulic sys tem with primary boiler circulation pump or hydraulic system with boiler bypass pump In case of system with boler bypass pump set parameter 81 1174 for output RO or 4 974 for output R9 10 AGFTK flue gases sensor for solid fuel boiler Controller blocks liquid fuel boiler operation if flue gases exceed tempe rature setted with parameter 5 19 Service setting manual 42 Para Parameter name Parameter description Setting Default meter setting T8 SENSOR FUNCTION Selection of function for sensor connected to input T8 1 RF2 room sensor in circuit 2 2 EF2 sensor for limitation of max floor temperature in circuit 2 Max floor temperature is set with parameter S3 11 3 RLF2 return pipe sensor in circuit 2 Activates limitation of difference between stand and return pipe and by that the limitation of max heating circuit power Max difference is set with parameter 53 14 4 RF1 room sensor in circuit 1 5 EF1 sensor for
107. g des Parameters Einstellungs Ubernom meter nung bereich mener Wert 2 3 DD2 RAUMF HLE Mit der Funktion stellen wir den Einfluss der F hler der REINFLUSS Raueinheiten DD2 auf dem Betrieb des ersten Heizkreises 1 Einfluss hat der F hler der Raumeinheit DD2 die 4 1 amp 2 002 4 BETRIEBSART DER Einstellung der Betriebsart der Umw lzpumpe Einstellungen UMW LZPUMPE haben folgende Bedeutung 45 Fu bo den Kodier Schalter der Raumeinheit S 4 ON 4 Einfluss haben beide F hler der Raumeinheiten DD2 5 Der F hler der Raumeinheit DD2 hat keinen Einfluss 1 STANDARD 2 AUS 3 PROG P1 4 PROG P2 den ersten Kreis regelt Kodier Schalter der Raumeinheit S 2 OFF Dies k nnen die erste die Zweite oder beide Raumeinheiten sein 2 Einfluss hat der F hler der ersten Raumeinheit DD2 Kodier Schalter der Raumeinheit S 4 OFF 3 Einfluss hat der F hler der zweiten Raumeinheit DD2 1 Standardbetriebsart der Umw lzpumpe 2 Ausschalten der Pumpe wenn die Raumtemperatur erreicht ist nur Direktheizkreiss 3 Arbeitet nach Zeitprogramm P1 PR 4 Arbeitet nach Zeitprogramm P2 6 Arbeitet nach dem Ausgew hlten Zeitprogramm MAXIMALE VOR Das Einstellen der Begrenzung der maximalen Vorlauftem 20 150 C LAUFTEMPERATUR Peratur 5 7 STILLSTAND DER MISCHVENTILREGE LUNG P KONSTANTE DER MISCHVENTILREGE LUNG 2 2 2 2 S29 1 KONSTANTE DER MISCHVENTILREGE LUNG D KONST
108. he Einstellung Raumeinheit steuert den Kreis 1 m ee De m Zweite Raumeinheit Das Anschlussshema der Raumeinheit DD2 cL 0 0 1 2 1 2 Erste Zweite Raumeinheit Raumeinheit Montageanleitungen 148 BUS VERBINDUNG DER WXD REGLER Mit der Bus Verbindung kann eine beliebige Anzahl von Reglern des Typs WXD miteinan der verbunden werden Der erste bzw f hrende Regler steuert physisch die W rmequellen und die anderen steuern nur die Heizkreise Wichtig Der F hler der Au en und Kesseltemperatur ist immer an den ersten Regler anzuschlie en Au enf hler Erster Regler Erweiterungsregler Erweiterungsregler W rmequelle BUS VERBINDUNG DER WXD UND CMP25 2 REGLER Mit der Bus Verbindung kann man den WXD Regler und eine beliebige Anzahl der CMP25 2 Regler mit einander verbinden WXD ist immer der erste bzw f hrende Regler und steu ert physisch die W rmequellen w hrend die CMP25 2 Regler die Heizkreise steuern Wichtig Der F hler der Au en und Kesseltemperatur ist immer an den ersten Regler anzuschlie en Au enf hler Erster Regler Schema 360b Schema 360b OD 149 Montageanleitungen Erweiterungsregler Erweiterungsregler W rmequelle MONTAGE UND ANSCHLUSS DES SICHERHEITSTERMOSTATES Bei der Flachenheizung
109. heating circuits Special algorithm activates the solar pump to switch on for short intervals This way realistic temperature of collectors is obtained This function is used especially with vacuum tube collectors or with classic collectors if the sensor is fitted outside of the collector body We define whether and how the minimum collector or solid fuel boiler temperature is respected CIRCUITS WITH DE LAYED ACTIVATION OF LIQUID FUEL BOILER SOLAR PUMP KICK FUNCTION RESPECT MIN TEMPE RATURE OF COLLEC TORS OR SOLID FUEL BOILER OPERATION MODE OF Setting of circulation pump ON OFF or RPM operation COLLECTORS OR SOLID mode RPM modulation of the pump is done with 5 stages FUEL BOILER CIRCULA 40 55 70 85 100 RPM TION PUMP MINIMUM RPM FOR PUMP Minimum RPM stage for modulation of circulation pump 1 40 RPM 2 55 RPM 3 70 RPM When the differential condition is fulfilled the circulation pump runs at max RPM for a setted time Afterwards the pump is running with RPM modulation if enabled with parameter S6 10 1 Cold sensor T8 place of mount if it is being used for differential thermostat In exact we define storage device which is being warmed with solar collectors or solid fuel boiler HEAT PUMP OPERATION Setting if heat pump should operate in ON OFF or wea ther compenstaed mode FULL RPM RUNNING TIME OF COLLECTORS OR SOLID FUEL BOILER CIRCULATION PUMP LOCATION OF COLD SE
110. heating function which is activated by changeo ver from night to day temperature period 6 Liquid fuel boiler is blocked Controller will operate only with solid fuel boiler T Counter for boiler operation time 51 7 ANTI BLOCK FUNCTION All outputs that haven t been activated the last week 0 NO activated on Friday between 20 00 and 20 15 for 60 seconds 1 YES REMOTE ACTIVATION Selection if remote activation can be activated only local or VIA BUS also from master controller 2 LOCALY amp FROM CIRCUITS FOR REMOTE Selection of circuits affected by remote activation 1 CIRCUIT 1 ACTIVATION 2 CIRCUIT 2 3 CIRCUIT objects select lower value OUTPUT RO FUNCTION Setting of output RO operation mode 1 output is used to control second stage of 2 stage burner 2 output is used for d h w circulation 3 output is used for d h w warming with electric heater 4 ou put is used to control boiler primary pump put is used to control heat pump 5 PRIMARY PUMP 6 HEAT BUILDING TYPE TIME Selection of building type time constant For heavy thick CONSTANT walls and good isolated buildings select higher value For light thin walls no heat accumulation and poor isolated Service setting manual 44 Para Parameter name Parameter description Setting Default meter range setting OUTPUT R9 FUNCTION Setting of output R9 operation mode 1 KTF output is used for solar differential therm
111. hler oder der Raumeinheit DD2 TA Au entemperatur gewonnen ber die Bus Verbindung TQ Temperatur der W rmequelle gewonnen ber die Bus Verbindung SYMBOLE DER SCHUTZFUNKTIONEN Symbol Beschreibung Raumeinheit DD2 ist angeschlossen Die Zahl neben der Raumein heit zeigt ob dies die erste oder die zweite Raumeinheit ist Regler und Kommunikation Port COM1 COM2 Status Einzel Regler nicht im BUS Netz Mittlere untergeordnete Regler im BUS Netz Der letzte untergeordnete Regler im BUS Netz 91 Bedienungsanleitung SYMBOLE F R WARNUNGEN UND MELDUNGEN Symbol Beschreibung Meldung Im Falle einer berschreitung der Maximaltemperatur oder des Einschaltens der Schutzfunktion teilt der Regler mit dem Blinken des Symbols am Display dies mit Wenn die Maximaltemperatur nicht mehr berschritten ist oder sich die Schutzfunktion schon ausge schaltet hat zeigt das leuchtende Symbol den k rzlich ereigneten Vorfall an Mit dem Dr cken der Taste wird der Bildschirm zur Kontrolle der Meldungen aufgerufen Warnhinweis Im Falle eines F hlerdefekts Fehlers einer Bus Verbindung oder einer Com Verbindung meldet der Regler einen Fehler mit einem FAN blinkenden Symbol am Display Wenn der Fehler behoben bzw nicht mehr vorhanden ist weist das leuchtende Symbol auf den k rzlich ereigneten Fehler hin Mit dem Dr cken der Taste wird der Bildschirm zur Kontrolle der Warnhinweise aufgerufen BI
112. ial rete na ASA PC thermoplastic Supply voltage eee cette 230 V AC 50 Hz Own CONSUMPTION nenn 5 VA Cable cross section 0 5 to 0 75 mm Degree of protection een IP20 according to EN 60529 Protector class iecore a according to EN 60730 1 Permissible ambient temperature 5 C to 40 C Permissible relative humidity max 85 Rh at 25 C Storage temperature nenn 20 C to 65 C Relay output pot free max 4 1 A 230 V R2 R3 R4 R5 R6 R7 4 1 A 230 V Triac output EE 1 1 A 230 V Timer RE 7 day program timer Min interv l u een 15 minutes Built in clock accuracy 5 min year E E EE A Data retention ssis min 10 years Technical characteristics temperature sensors Type of temperature sensors Pt1000 or KTY10 Resistance of temperature sensors POOO e ere e vex to PD ES EE 1078 Ohm at 20 C KIYIO TREES 1900 Ohm at 20 C Temperature scope Outdoor sensor At 25 65 C IP32 Immersion sensor 25 150 C IP32 Surface sensor 0 85 C IP32 Flue gases sensor 20 350 C IP32 Conductor cross section
113. icher Mischerheizkreis Brauchwassererw rmer zi N Dk E NS gt 4 F e iex 6 GND X 3 GND ae 7 5 R1 T6 fi T3 Lars 174 422 WXD20 Heat pump heat accumulator with a built in d h w storage tank mixing circuit W rmepumpe W rmespeicher mit eingebauten Brauchwassererw rmer Mischerheizkreis N nt IN e ie 422b WXD20 Heat pump oil boiler heat accumulator with a built in d h w storage tank mixing circuit W rmepumpe Fl ssigbrennstoffkessel W rmespeicher mit eingebauten Brauchwassererw rmer Mischerheizkreis bk B 3 T2 E Ch Y at rr 175 422c WXD20 Heat pump oil boiler heat accumulator mixing circuit d h w storage tank W rmepumpe Fl ssigbrennstoffkessel Warmespeicher Mischerheizkreis Brauchwassererwarmer 4 N R INS e e 422d WXD20 Heat pump oil boiler heat accumulator with a built in d h w storage tank mixing circuit W rmepumpe Fl ssigbrennstoffkessel W rmespeicher mit eingebauten Brauchwassererw rmer Mischerheizkreis 4 o 5 TH e e 176 423 WXD20 Oil boiler 2x mixing circuit d h w storage tank Fl ssigbr
114. ion when heating is active TEMPERATURE C 85 radiat VALVE CONTROL mixing valve control is in stand by C Setting of mixing valve position correction intensity Smaller value means shorter movements higher value means longer mixing valve movements Setting of mixing valve control frequency how often mixing valve position is being controlled Smaller value means low frequency higher value means higher frequency of mixing valve corrections Sensitivity of mixing valve for stand pipe temperature chan ges Smaller value means low sensitivity higher value means high sensitivity Setting of maximum floor temperature limitation by floor heating Setting is active only if floor sensor is installed and parameter 1 4 2 for sensor 1 or S1 5 5 for sensor T8 Setting of minimum stand pipe temperature in cooling mode CAUTION Too low stand pipe temperature can cause dewing of heating bodies and pipelines Shift of calculated min stand pipe temperature by which the mixing valve control will activate Negative values mean activation of mixing valve control by lower calculated stan pipe temperatures positive values mean activation of mixing valve control by higher calculated stand pipe temperatures 46 Para Parameter name Parameter description Setting Default meter range setting LIMITATION OF TEMP Setting of maximal difference between stand pipe and return DIFFERENCE BETWEEN Pipe temperature This way the
115. ions are available only by schemes with two heating circuits Functions are available only by schemes with liquid fuel boiler and solid fuel boiler User manual 26 Holiday operation mode HOLIDAY function activates operation according to the requested saving temperature up to selected date Select Holiday function with buttons and and activate it with the V button To set the expiration date and requested temperature select the fh icon again Now use the and buttons to select the setting you wish to change and press the button The value will begin to flash Change the value with buttons and and confirm it by pressing the V button Exit the setting by pressing the button USER FUNCTIONS FOR D H W WARMING One time activation of d h w warmin This function activates immediate d h w warming to the requested temperature When the requested d h w temperature is reached the function deactivates automatically Use buttons and to select the one time d h w warming and activate it by pressing the V button Exit the setting by pressing the button USER FUNCTIONS FOR HEAT SOURCES One time activation of liquid fuel boiler This function activates immediate switchover from solid fuel boiler or heat accumulator to liquid fuel boiler One time activation of liquid fuel boiler can only be activated if solid fuel boiler or heat accumulator temperature is lower as calcula
116. is connected The number beside room unit indi cates whether this is the first or the second room unit IA State of the controller in bus connection e KI Standalone controller not in bus network User manual 18 SYMBOLS FOR MESSAGES AND WARNINGS Message In the event of exceeding the maximum temperature or when a protection function is switched on the symbol on display flashes When maximum temperature is no longer exceeded or when a protection function has switched off a turned on symbol will note the recent event By pressing the button the message review screen is retrieved Warning In the event of sensor malfunction bus network error or com connec tion error the symbol on display flashes When the error is eliminated or is no longer present a turned on symbol will note the recent event By pressing the button the message review screen is retrieved HELP MESSAGES AND WARNINGS SCREEN By pressing the button the help messages and warnings screen is retrieved A new window opens with the following icons Short instructions Short instructions on the use of controller Ever Controller version Review of the controller type and program version Messages List of exceeded maximum temperatures and list of activated protection func tions By pressing the buttons and navigate through the list of messages Exit the list by pressing the button Warnings List of sensors and other c
117. itprogramm auf die gew nschte Tages und Nacht Temperatur eingestellt auf dem Regler Betrieb l uft nach dem ausgew hlten Zeitprogramm auf die gew nschte Tages und Nacht Temperatur eingestellt auf der DD2 Betrieb nach Tagestemperatur Der Regler arbeitet nach Soll Tagestemperatur eingestellt auf dem Regler Betrieb nach Nachttemperatur Der Regler arbeitet nach Soll Nachttemperatur eingestellt auf dem Regler Aus Der Regler ist ausgeschaltet Wenn Heizbetrieb ausgew hlt ist bleibt der Frostschutz aktiv Wenn K hlbetrieb ausgew hlt ist bleibt der berhitzungs schutz aktiv BETRIEBSART F R DAS BRAUCHWASSER EEE Brauchwassererw rmung nach ausgew hltem Zeitprogramm Das Brauchwasser wird nach dem ausgew hlten Zeitprogramm erw rmt Dauerbetrieb der Brauchwassererw rmung Die Brauchwassererw rmung arbeitet ununterbrochen Aus Das Brauchwasser wird nicht erw rmt Das Men steht nur bei Schemen mit zwei Heizkreisen zur Verf gung Bedienungsanleitung 102 MANUELLER BETRIEB Diese Betriebsart wird zur Pr fung des Heizsystems oder im Falle eines Defekts verwen det Jeder Steuerausgang kann manuell eingeschaltet ausgeschaltet oder auf Automatik betrieb eingestellt werden Zwischen den einzelnen Ausg ngen R1 bis R9 bewegt man sich mit den Tasten und Der Ausgang dessen Status ver ndert werden soll wird mit Dr cken der Taste ausgew hlt ON OFF oder AUTO f ngt zu blinken an Jetzt
118. k 1 12 1 56 13 1 Picture 1 D h w storage tank Required parameter settings for application with heat accumulator 1 12 1 6 13 2 Picture 2 Heat accumulator Service setting manual 64 APPLICATION OF DIFFERENTIAL CONTROLLER FOR SOLID FUEL BOILER Required parameter settings for application with storage tank 1 12 2 6 13 1 Picture 1 D h w storage tank Required parameter settings for application with heat accumulator Picture 2 Heat accumulator 410b 411 413 416 416b 416c 417 418 419 420 421 422 422b 422c 422d 423e 423f 423g and 423h Schemes 404 404b 404c 404d 404e 404 405 406 and 407b already in clude a differential controll of the solar system Differential controller be activated in schemes 408 408 409 409 410 65 Service setting manual OPERATION MODES IN CASES OF SENSOR MALFUNCTION Outdoor sensor is not connected or has a failure In such case the controller operates as a P controller according to room temperature de viation If room temperature sensor also has a failure or is not connected the controller will maintain constant stand pipe temperature which is 25 C higher as the set day or night temperature for radiator heating system 10 C higher
119. k solar collectors W rmespeicher Mischerheizkreis Brauchwassererw rmer Solarkollektoren T2 Lu 404c WXD10 WXD20 Solid fuel boiler mixing circuit d h w storage tank solar collectors Festbrennstoffkessel Mischerheizkreis Brauchwassererwarmer Solarkollektoren 4 x N Ott e 159 404d WXD10 WXD20 Heat accumulator with a built in d h w storage tank mixing circuit solar collectors Warmespeicher mit eingebauten Brauchwassererwarmer Mischerheizkreis Solarkollektoren aj N THER 404e WXD10 WXD20 Heat accumulator with a built in d h w storage tank mixing circuit solar collectors W rmespeicher mit eingebauten Brauchwassererw rmer Mischerheizkreis Solarkollektoren 4 NO N o x Ott 160 404f WXD10 WXD20 Expansion scheme mixing cir
120. kann der Status des Ausgangs mit den Tasten und ver ndert werden Die Einstellung best tigt man mit der Taste V Die Einstellung verl sst man mit dem Dr cken der Taste D AuswaHL DER HEIZUNG ODER KUHL BETRIEBS Heizung 4 K hlung Die Regulierung der K hlung l uft ber ein Thermostat in Abh ngigkeit von der Soll Raumtemperatur und funktioniert mit einer konstanten Zufuhrtem peratur Die Temperatur wird mit dem Parameter 2 12 und 53 12 einge stellt Damit die K hlung l uft muss unbedingt der Raumf hler oder die Raumein heit angeschlossen und das System zur K hlwasserzufuhr eingeschaltet sein Bei der Umschaltung zwischen Heizung und K hlung wird die gew nschte Tages und Nachttemperatur ver ndert MESSUNGEN DER EMMISIONEN Diese Betriebsart ist f r die Emissionsmessung bestimmt Der Regler aktiviert den Bren ner und h lt die Kesseltemperatur zwischen 60 C und 70 C mit geeigneter Ansteue rung von Lasten Heizkreise Brauchwasser Dadurch ist der Betrieb des Kessels ohne Brenner Auschaltungen erm glicht Die Funktion ist automatisch nach 20 Minuten ausgeschaltet Indem Sie das Symbol ein weiteres Mal bet tigen beenden Sie die Funktion fr her 103 Bedienungsanleitung e Zeitprogramme einstellen W chentliche Zeitprogramme erm glichen ein automatisches Umschalten zwischen der Tages und Nacht Temperatur und Ein und Aus schalten der Brauchwasserbereitung Ill Erster Heizkr
121. l benutzt werden S1 4 9 In diesem Fall erfolgt die Umschaltung auf Festbrennstoffkessel auch wenn die Temperatur der Rauchgase den eingestellten Wert berschreitet Hierbei muss man noch die Parameter S1 4 7 f r T1 oder 1 5 10 f r T8 einstellen Eingestellt wird die maximale Temperatur der Rauchgase Wird der eingestellte Temperaturwert der Rauchgase berschritten warnt uns der Regler F r die Funktion ist ein Rauchgasf hler und die Einstellung S1 4 7 f r T1 oder S1 5 10 f r T8 notwendig Einstellung der minimalen Rauchgastemperatur des Fest brennstoffkessels Beim berschreiten dieser Temperatur ist der Fl ssigbrennstoffkessel au er Betrieb Diese M glichkeit wird angewandt wenn der Fl ssigbrennstoff kessel und der Festbrennstoffkessel an den gleichen Schornstein angeschlossen sind und nicht gleichzeitig betrieben werden d rfen Hierbei m ssen die Parameter S1 4 10 f r T1 oder 1 5 13 f r T8 eingestellt werden Einstellung der Ausschaltdifferenz zwischen der Kessel temperatur und der R cklauftemperatur in den Kessel bei der die Pumpe des R cklaufs des Kessels ausgeschaltet wird Mit dieser Einstellung schalten wir die maximale Schutztemperatur der Sonnenkollektoren oder Fest brennstoffkessel ein Wenn die Sonnenkollektoren oder der Festbrennstoffkessel die eingestellte Temperatur berschreitet kann die Brauchwasserpumpe erneut ein geschaltet werden obwohl die gew nschte Brauchwas sertempera
122. ler and prevents condensation in boiler fireplace To assure proper operation the hydraulic connection must feature primary circulation of boiler water 55 Service setting manual DIRECT HEATING CIRCUIT Required supply temperature for the direct heating circuit is provided directly by controlling the boiler temperature Heating switch off If the calculated stand pipe temperature isn t for few C higher than the room temperature the heating is automatically switched off Heating is automatically switched off if room temperature is not measured and when outdoor temperature approaches the required temperature The temperature difference at which the boiler will switch off can be increased or decreased with parameter S3 13 At automatic heating switch off a temperature of 4 C is set for stand pipe temperature and the circulation pump is switched off with delay parameter S3 16 Other pump operation modes can be selected with parameter S3 4 LIQUID FUEL BOILER For the required liquid boiler temperature the highest temperature from the list below is taken calculated first stand pipe temperature increased for the value of parameter S5 3 calculated second stand pipe temperature increased for the value of parameter 55 4 requested d h w temperature increased for the value of parameter S5 5 calculated boiler temperature of an additional direct heating circuit calculated boiler temperature from slave controllers in BUS
123. ler mit der beigelegten Wandschraube auf die vorgesehene Stelle eindrehen Das Ka bel in den F hler durch die Einf hrung von der unteren Seite f hren und anschlie en Raumtemperaturf hler Raumtemperaturf hler an die Innenwand des Wohnzimmers die nicht dem Sonnenlicht ausgesetzt ist und fern von W rmequellen und Durchzug montieren Zuerst den Deckel abnehmen dann den Sockel an die ausgesuchte Stelle ca 1 5 Meter ber dem Fu boden aufschrauben Die Montage kann auf die Standard Unterputzdose oder direkt an die Wand erfolgen F r den elektrischen Anschluss brauchen Sie ein zweiadriges Signalkabel Wenn in dem Raum in dem sich die Raumeinheit befindet an Heizungsk rpern Thermostatven tile eingebaut sind m ssen diese vollst ndig ge ffnet sein Wenn der Raumtemperaturf hler an die Klemme T1 angeschlossen ist muss der Parame ter S1 4 1 unbedingt eingestellt sein Wenn der Raumtemperaturf hler an die Klemme T8 angeschlossen ist muss der Parame ter S1 5 1 oder S1 5 4 unbedingt eingestellt sein 51 5 4 147 Montageanleitungen ANSCHLUSS DER RAUMEINHEIT DD2 Der WXD Regler erm glichen einen Anschluss der digitalen Raumeinheit DD2 die die Periodentemperatur misst und die Einstellung der Soll Tagestemperatur und Soll Nacht temperatur und die Auswahl der Betriebsart erm glicht An einen Regler k nnen bis zu zwei Raumeinheiten angeschlossen werden Einstellung der Kodierschalter an die Raumeinheit DD2 Obligatorisc
124. licht das Einschalten des Betriebs gem der Soll Spartempe ratur Mit den Tasten und w hlt man die ECO Funktion aus und mit der Taste schaltet man sie ein F r das Einstellen der Uhr f r den Ablauf der Funktion und der Soll Temperatur w hlt man erneut die Ikone ZC aus Jetzt w hlt man mit den Tasten und die Einstellung aus die ver ndert werden soll und dr ckt auf die Taste V Der Wert f ngt an zu blinken Mit den Tasten und wird der Wert ver ndert und mit der Taste V best tigt Die Einstellung verl sst man mit dem Dr cken der Taste 22 Einstellung steht nur bei Schemen mit zwei Heizkreisen zur Verf gung Funktionen stehen nur bei Schemen mit Umschaltung von W rmequellen zur Verf gung 99 Bedienungsanleitung Urlaubsmodus Die URLAUB Funktion schaltet die Regulierung des Heizkreises gem der gew nschten Spartemperatur bis zum festgelegten Datum ein Mit den Tasten und w hlt man die Urlaub Funktion aus und mit der Taste V schaltet man sie ein F r das Einstellen des Ablaufdatums der Funktion und Temperatur w hlt man erneut die Ikone amp amp aus Jetzt w hlt man mit den Tasten und die Einstellung aus die ver ndert werden soll und dr ckt auf die Taste V Der Wert f ngt an zu blinken Mit den Tasten und wird der Wert ver ndert und mit der Taste V best tigt Die Einstellung verl sst man mit dem Dr cken der Taste BENUTZERFUNKT
125. limitation of max floor temperature in circuit 1 Max floor temperature is set with parameter S2 11 6 RLF1 return pipe sensor in circuit 1 Activates limitation of difference between stand and return pipe and by that the limitation of max heating circuit power Max difference is set with parameter S2 14 T BF3 d h w circulation with temperature sensor Sensor is placed onto hot exit pipe from storage tank D h w circu lation pump is activated if temperature increase is detected Duration time of circulation is set with parameter P4 8 8 SVS d h w circulation with flow switch D h w circula tion pump is activated if contact are closed Duration time of circulation is set with parameter P4 8 9 BF2 auxiliary sensor in d h w storage tank It is installed in upper third of storage tank Warming of d h w will activate only when BF2 sensor detects drop of temperature 10 AGF flue gas temperature sensor for boiler Warning is displayed on the screen if flue gas temperature rises above value of parameter 5 18 11 RFHP room sensor in ambient where d h w heat pump is installed D h w warming with other heat sources is disab led if room temperature is higher as set with parameter 4 11 12 RLKF boiler return pipe sensor Controller maintains min level of boiler return pipe temperature set with parameter 5 14 For this setting it is necessary to have a hydraulic sys tem with primary boiler circulation pump or hy
126. mann mn Combined liquid and solid fuel boiler temperature Heat source temperature supply temperature sensor Stand pipe temperature Return pipe temperature Domestic hot water temperature The number indicates the first or the second heating circuit 15 User manual WC BCEE RE KEE stat yoa puno programmani dironta memos _ HE e Burner Burner second stage Bypass pump of the heating circuit flashing means the pump will switch off after expiration of delay time R0123456789 Status of the controller s control outputs relays are switched on R Status of the controller s control outputs relays are switched off Mixing valve closing Mixing valve opening Change over valve direct circuit Change over valve d h w storage tank D h w warming pump Circulation pump for d h w Solar collectors pump Boiler bypass pump Boiler circulation pump User manual a SS 8 secorra T1 T2 T3 T9 S measured by sensors T1 T2 T3 T4 T5 T6 T7 T8 or Temperature measured by a room sensor or room unit DD2 Outdoor temperature obtained through the bus connection Heat source temperature obtained through the bus connection Calculated requested temperature for direct circuit D h w warming is switched off due to priority of direct heating circuit Heating circuit is switched off or has limited t
127. meter S1 4 5 for sensor T1 or S1 5 8 for sensor T8 The switch needs to be installed on the exit pipe from the d h w storage tank hot pipe If flow switch detects flow the d h w circulation pump is switched on for the time set with parameter P4 8 REMOTE HEATING ACTIVATION Setting the parameter S1 6 1 enables a remote activation of room heating and d h w warming with telephone controlled switch Telewarm G1 D or any other device with a poten tial free control switch Room heating according to the requested day time temperature and d h w warming are activated if a short circuit is detected on input T1 T6 or T8 In a BUS connection of more controllers the request for remote activation on master con troller is accepted also on slave controllers if defined with parameter 51 8 OPERATION OF HEATING SYSTEMS WITH TWO HEAT SOURCES WXD controllers feature fully automatic operation of heating systems with two heat sourc es for example with solid and liquid fuel boiler Systems can operate with or without a heat accumulator The hydraulic connection of the two heat sources can be parallel or serial Service setting manual 60 Operation diagram for hydraulic schemes with two heat sources temperature delay to start Source 1 1 0 i 5 E time LEGEND A liquid fuel boiler heat source A B solid fuel boiler or heat accumulator heat source B PT switchover temperature
128. n die R cklauftemperatur unter die Minimaltempe ratur Parameter S5 14 sinkt wird das Mischventil stufenweise geschlossen So wird der Kessel entlastet und die Kondensierung in der Feuerungsstelle des Kessels verhindert F r 131 Wartungsanleitung den ordnungsgem en Betrieb muss die Hydraulikverbindung die prim re Kesselwasser zirkulation sicherstellen Regulierung des Mischerheizkreises mit konstanter Temperaturr Wenn die Regulierung der konstanten Vorlauftemperatur ben tigt wird erreicht man dies mit der der Einstellung des Parameters S2 15 f r den ersten Kreis und S3 15 f r den zwei ten Kreis DIREKTHEIZKREIS Mit der Kesselsteuerung wird die notwendige Temperatur der Direktheizkreis Zuleitung sichergestellt Heizung ausschalten Wenn die ausgerechnete Vorlauftemperatur nicht leicht h her ist als die Raumtemperatur schaltet sich die Heizung automatisch aus Wird die Raumtemperatur nicht gemessen schaltet sich die Heizung automatisch aus wenn die Au entemperatur fast gleich der Soll Raumtemperatur ist Mit dem Parameter S3 13 wird der Temperaturunterschied bei dem sich die Heizung ausschaltet vergr ert oder verringert Beim Ausschalten der Heizung wird 4 C als Wert f r die ausgerechnete Vorlauftemperatur bernommen und die Umw lzpumpe wird mit Verz gerung Parameter S3 16 ausge schaltet Mit dem Parameter S3 4 k nnen andere Funktionsm glichkeiten der Pumpe ausgew hlt werden FL SSIGBRENNSTOFFKES
129. ng VERZ GERT Die Einstellung ist nur Wirksam bei Schemata mit zwei Warmequellen GEWUNSCHTE Mit der Einstellung wird die gew nschte Temperatur der 50 90 BRAUCHWASSERTEM Brauchwasser bei Erw rmung mit Sonnenkollektoren oder PERATUR BEI HEIZEN Festnbrennstoffkessel bestimmt MIT KOLLEKTOREN ODER FESTBRENN STOFFKESSEL MIN RAUMTEMP MIT Solange die Raumtemperatur h her als der eingestell W RMEPUMPE F R te Wert ist blockiert der Regler die Erw rmung der BRAUCHWASSER Brauchwasser aus dem System der Zentralbeheitzung Das Wasser wird nur durch die eingebaute W rmepumpe erhitzt F r die richtige Funktionsweise ist die Einstellung von S1 4 8 f r T1 und S1 5 11 f r T8 n tig AUSSCHALTVER Mit der Einstellung bestimmen wir die Ausschaltver 0 10 Min Z GERUNG DER z gerung der Umw lzpumpe wenn die gew nschte UMW LZPUMPE Temperatur der Brauchwasser erreicht ist 4 12 AUSSCHALTVER Mit der Einstellung bestimmen wir die Ausschaltver 10 Min ZOGERUNG DER z gerung der Umw lzpumpe wenn die gew nschte UMWALZPUMPE Temperatur der Brauchwasser erreicht ist Wartungseinstellungen f r Kessel Para Parameterbezeich Beschreibung des Parameters Einstellungs bernom meter nung bereich mener Wert 5 1 MAXIMALE KESSEL Das Einstellen der maximalen Kesseltemperatur f r 60 160 C TEMPERATUR Fl ssigbrennstoffkessel HYSTERESE UND ART Mit der Einstellung wird die Art der Brennersteuerung und 1
130. ng ausgeschaltet ist OFF Festlegung ob die Brauchwassererw rmung Vorrang vor der Erhitzung des Heizkreises 1 hat Festlegung ob die Brauchwassererw rmung Vorrang vor der Erhitzung des Heizkreises 2 hat 111 bernom mener Wert 0 7 Fu bo den 1 0 Radia toren 15 15 C bernom mener Wert Wartungsanleitung Para Parameterbezeichnung Beschreibung des Parameters Einstellungsbe bernom meter reich mener Wert ZEITPROG ZUR BRAUCHWASSERZIR KULATION P4 FUNKTIONSZEIT DER ZIRKULATIONSPUMPE m RUHEZEIT DER ZIRKU LATIONSPUMPE Festlegung des Zeitprograms zur Steuerung der Brauchwasserzirkulation Einstellung 1 bedeutet die Funktion nach dem ersten Zeitprogram zur Brauchwassererw rmung Einstellung 2 bedeutet die Funktion nach dem zweiten Zeitprogram zur Brauchwassererw rmung Einstellung 3 bedeutet die Funktion nach Zeitprogram zur Brauchwassererw rmung welches zur Zeit ausgew hlt ist Einstellung des Intervalls zur Funktion der Zirkulati onspumpe Dem Funktionsintervall folgt immer ein Ruheintervall Einstellung des Ruheintervalls der Zirkulationspumpe Dem Ruheintervall folgt immer ein Funktionsintervall Einstellungen f r die Kessel Para Parameterbezeichnung Beschreibung des Parameters Einstellungsbe bernom meter reich mener Wert MINIMALE TEMPERA TUR DES FLUSSIG BRENNSTOFFKESSELS MINIMALE TEMPERA TUR DES FESTBRENN STOFFKESSELS MINIMALE TEMPE
131. ngen und Warnungen 92 Einstieg und Navigation im Menu eod Benson 93 Men struktur und Beschreibung 93 Temiperaturelnstellting E 98 BenutZzerfunktionen nennen enean tenen nt Erai aiarad 99 Betnebsartenwahl iiie ia t spe EE 102 Zeitprogramme einstellern o eec entren en 104 Grundeinstellungen ET T 106 DatendKontrolle rie een deele 108 WARTUNGSANLEITUNGEN ee 109 SE 109 Heizkurvensteillielt ea 113 Elie Del EE 115 Parameter f r Estrichtrocknung Heinen 129 Mnscmm 130 MischerhelzKfelSe leue eee ette e ce e EO PERS SEES EPOR EE CER PG US DECR F Lena DOR POE Ga 131 Gr ndfunktionbeschreibungen senponta an ete petat deoa it nean ran a 131 BI Iis Sigla EPOR LL UU LU LE LIU 132 Fl ssigbrennstoffKessel e aaaea hepar repete i taper 132 FestbrennstoffKessel icere sexus a iE PCR Red eL DR LEX RE 133 WarmesSpeichera iicet ie e aeter tese oos 134 80 Elie Kesselbeimischpumpe BYPASS ernennen nennen Br auchW sser nannten BrauchwasserzlirkulatlOn terere tit radere erede tetto onen Fernelnschaltung der Heizung enne eterna Funktion der Heizsysteme bei zwei
132. nikschrott Stoffverbote RoHS II 2011 65 EC PRODUKTBESCHREIBUNG Witterungsgef hrter Heizungsregler TYP WXD10B WXD10 WXD20 ANGEWANDTE NORMEN EN60730 1 2001 EN60730 1 2001 A2 2009 EN60730 2 9 2002 EN60730 2 11 2008 EN61000 6 1 2007 EN55014 1 2007 EN12098 1 2002 ENTSORGUNG VON GEBRAUCHTEN ELEKTRISCHEN UND ELEKTRONISCHEN GERATEN Entsorgung von gebrauchten elektrischen und elektronischen Ger ten Anzuwenden in den L ndern der Europ ischen Union und anderen europ ischen L ndern mit einem sepa raten Sammelsystem f r diese Ger te Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin dass dieses Produkt nicht als normaler Haushaltsabfall zu behandeln ist sondern an einer Annahmestelle f r das Recycling von elektrischen und elektronischen Ger ten abgegeben werden muss Durch Ihren Beitrag zum korrekten Entsorgen dieses Produkts sch tzen Sie die Umwelt und die Gesundheit Ihrer Mitmenschen Umwelt und Gesundheit werden durch falsches Entsorgen gef hrdet Materialrecycling hilft den Verbrauch von Rohstoffen zu verringern Weitere Informationen ber das Recycling dieses Produkts erhalten Sie von Ihrer Gemeinde den kommunalen Entsorgungsbetrieben oder dem Gesch ft in dem Sie das Produkt gekauft haben 153 Deklarationen HYDRAULIC SCHEMES HYDRAULIKSCHEMAS IMPORTANT ATTENTION Installation schemes show operation principles and do not include all auxil iary and safety elements Observe the regula
133. nleitung 138 BETRIEB DES UMSCHALTVENTILS BEI ZWEI WARMEQUELLEN Zur Steuerung des Umschaltventils benutzen wir einen Stellmotor mit Zwei Punkt Steue rung R ckkehr in die Ausgangsposition kann durch eine Feder oder durch kontinuierliche Netzstromversorgung durchgef hrt werden Der Punkt auf den hydraulischen Schemen zeigt den Anschluss an der ge ffnet ist wenn der Stellmotor in seiner Ausgangsposition liegt Erw nscht ist dass dies der Anschluss ist der an den Festbrennstoffkessel den Speicher oder an die Zufuhrleitung von Fl ssigbrenn stoffkessel beim Schema 121 angeschlossen ist Mit Hilfe der Parameter Einstellung S5 16 1 k nnen wir die Funktionsweise des Steuer relais R8 Invertieren Dies erm glicht auch andere anschlussvarianten des Umschaltven tils wie unten dargestellt UMSCHALTEN VON W RMEQUELLEN Parallel Verbindung Empfohlene Werks Einstellung Alternativ Einstellung S1 16 0 S1 16 1 LEGENDE A Fl ssigbrennstoffkessel B Festbrennstoffkessel oder Warmespeicher e Markiert den Anschluss der offen in der Ausgangsposition des Umschaltventils ist 139 Wartungsanleitung Serien verbindung Empfohlene Werks Einstellung Alternativ Einstellung S1 16 1 LEGENDE A Fl ssigbrennstoffkessel B Festbrennstoffkessel oder Warmespeicher e M
134. ns and Confirm the selected value by pressing The controller requires confirmation of the set heat ing curve steepness with the V button In case you choose the wrong heating curve steep ness return to heating curve steepness selection with the button meaning of heating curve steepness is detaily described on page 36 Later you can change the heating curve steepness with parameter P2 1 The User manual 10 STEP 4 SETUP OF THE HEATING CURVE STEEPNESS FOR THE SECOND CIRCUIT Set the heating curve steepness for the second heat ing circuit 901 2 0 Change the value with buttons and Confirm the selected value by pressing The controller requires confirmation of the set heat Do vou really wart ing curve steepness with the V button to continue In case you choose the wrong heating curve steep ness return to heating curve steepness selection with the button Later you can change the heating curve steepness with parameter P3 1 The meaning of heating curve steepness is detaily described on page 37 The first and the second heating circuit is marked with number on hydraulic schemes RESET Disconnect the controller from power supply Press and hold the button and connect power supply Attention The controller will be reset and requires additional setting When the controller is reset all of its previous settings are deleted 1 This setting is not available in schemes with
135. nung Beschreibung des Parameters Einstellungsbe Ubernom meter reich mener Wert PARALLELVERSCHIE BUNG DER HEIZKUR VE HEIZKURVESTEILHEIT Die Steilheit der Heizkurve bestimmt wie hoch an DAUER DER BOOST HEIZUNG Wartungsanleitung 0 7 Fu bo den 1 0 Radia toren Hand der Au entemperatur die Temperatur der Heiz k rper sein soll Siehe Kapitel Heizkurvesteilheit Einstellen der Parallelverschiebung der Heizkurve 15 15 C beziehungsweise der errechneten Vorlauftemperatur Das Einstellen dient der Aufhebung der Differenz zwischen gew nschter und Ist Raumtemperatur Die Zeiteinstellung f r die gew nschte Dauer der Raumtemperaturerh hung beim bergang vom Nachttemperatur Intervall auf das Tagestemperatur Intervall 0 200 min 110 Para Parameterbezeichnung Beschreibung des Parameters Einstellungsbe Ubernom meter reich mener Wert RAUMTEMPERA Para Parameterbezeichnung Beschreibung des Parameters Einstellungsbe meter reich TURERH HUNG BEI BOOST HEIZUNG HEIZKURVESTEILHEIT PARALLELVERSCHIE BUNG DER HEIZKURVE DAUER DER BOOST HEIZUNG RAUMTEMPERATURER HOHUNG BEI BOOST HEIZUNG HEIZKURVESTEILHEIT F R ZUSATZLICHE DIREKTE HEIZKREISE PARALLELVERSCHIE BUNG DER HEIZKURVE F R ZUS TZLICHE DIREKTE HEIZKREISE Das Einstellen der Temperaturh he f r die h here gew nschte Raumtemperatur beim bergang vom Nachttemperatur Intervall auf das Tagestemperatur
136. omponent malfunctions By pressing the buttons and navigate through the list of messages Exit the list by pressing the button E sg Delete list of messages and warnings Delete list of messages list of warnings and all unconnected sensors Attention You will not be able to delete the sensors necessary for the control ler s operation B 19 User manual ENTERING AND NAVIGATING THROUGH THE MENU msg TR1 A 20 0 2 025 OA To enter the menu press the V button To navigate through the menu use buttons and and confirm your selection by press ing the V button You can return to the previous screen by pressing 5 off or reduced according to the setting If no button is pressed for some time the screen illumination will be switched MENU STRUCTURE AND DESCRIPTION TEMPERATURES SETTING The setting is only available in schemes with two heating circuits User manual 20 ECO operation mode Holiday operation mode Function switch off le USER FUNCTIONS FOR THE SECOND HEATING CIRCUIT PARTY operation mode ECO operation mode elek Holiday operation mode x Function switch off c D m TI c z e d o z D o 5 c x One time switch on of d h w warming Function switch off USER FUNCTIONS FOR ENERGY SOURCES 1 One time switch on of liquid fuel boiler Switch off block of liquid fuel boiler amp Start
137. ostat 2 KF2 output is used for solid fuel boiler differential thermostat 3 output is used for d h w circulation 4 output is used for d h w warming with electric heater 5 output is used T8 6 PRIMARY 6 output is used to control boiler primary pump PUMP 7 output is used to control heat pump T HEAT PUMP SENSOR 1 CALIBRA Correction of displayed measured temperature for sensor 1 5 5 TION Correction of displayed measured temperature for sensor T2 TION SENSOR T3 CALIBRA Correction of displayed measured temperature for sensor T3 5 5K por Correction of displayed measured temperature for sensor T4 TION 1 47 Correction of displayed measured temperature for sensor T5 TION SENSOR T6 CALIBRA Correction of displayed measured temperature for sensor 6 5 5 pem Correction of displayed measured temperature for sensor T7 TION Correction of displayed measured temperature for sensor T8 TION 1 52 Service settings for the first heating circuit meter range setting INFLUENCE OF ROOM Set the influence of room temperature deviation Lower value 0 0 3 0 INFLUENCE OF ROOM Setting of room sensor T1 or T8 influence on the operation of 1 AUTO SENSOR T1 OR T8 first circuit 1 automatic room sensor influence room sensor has no influence if room unit DD2 is connected room sensor has influence if room unit DD2 isn t connected 2 room sensor has influence 3 room sensor has no influen
138. ou can review temperature graphs by moving between sensors with buttons and Press button on selected sensor Date begins to flash Now move between days with buttons and Press button to return to sensor selection You can change the range of temperature display on the graph with the but ton Exit temperature review by pressing the 29 button 34 SERVICE SETTINGS MANUAL CONTROLLER PARAMETERS All additional settings and adaptations of the controller s operations are performed with the help of parameters Available are user service and function parameters Located are on the second menu screen In each group only the parameters used in the selected hydraulic scheme can be seen Factory set values of parameter settings also depend on the selected hydraulic scheme USER PARAMETERS User parameters are divided into the following groups P1 general settings P2 settings for the first heating circuit P3 settings for the second heating circuit P4 settings for do mestic hot water P5 settings for boilers and P6 settings for alternative energy sources When you select the requested group of parameters in the menu a new Screen appears Parameter mark P1 1 Graphic display of the setting Factory set value AUT SWITCHOVER SUMMER Parameter NDS description HENES Setting range Current parameter value L Current parameter value Last confirmed setting v
139. pe K l 3 5 0 C ratur numerische Darstellung a Ausgew hlte Temperatur Zuletzt best tigter Einstellwert Graphische Darstellung der Werkseinstellungswert Einstellung Einstellungsbereich Aktueller Wert der Soll Temperatur Mit den Tasten und wird die Soll Temperatur eingestellt und mit der Taste V wird sie best tigt Die Einstellung verl sst man mit dem Dr cken der Taste SD Bedienungsanleitung 98 xi B BENUTZERFUNKTIONEN Die Benutzerfunktionen erm glichen einen zus tzlichen Komfort und Funktionalit t beim Gebrauch des Reglers Im Men stehen Ihnen folgende Benutzerfunktionen zur Verf gung Erster Heizkreis IS Zweiter Heizkreis Brauchwasser kk Energiequellen BENUTZERFUNKTIONEN F R DEN ERSTEN UND ZWEITEN HEIZKREIS Y PARTY Modus Die PARTY Funktion erm glicht das Einschalten des Betriebs gem der Soll Komforttem peratur Mit den Tasten und w hlt man de Party Funktion aus und mit der Taste schaltet man sie ein F r das Einstellen der Uhr f r den Ablauf der Funktion und der Soll Temperatur w hlt man erneut die Ikone aus Jetzt w hlt man mit den Tasten und die Einstellung aus die ver ndert werden soll und dr ckt auf die Taste V Der Wert f ngt an zu blinken Mit den Tasten und wird der Wert ver ndert und mit der Taste V best tigt Die Einstellung verl sst man mit dem Dr cken der Taste D ECO Funktion Die ECO Funktion erm g
140. r domestic hot water 3 SELECT warming PROG Setting 2 is second time program for domestic hot eater warming Setting 3 is selected time program for domestic hot water warming P RUNNING TIME FOR Setting of running time for d h w circulation pump Pump 0 600 sec D H W CIRCULATION running period is always followed by the pump stand by PUMP period STAND BY TIME FOR Setting of stand by time for d h w circulation pump D H W CIRCULATION Pump stand by period is always followed by the pump 1 PUMP running period 37 Service setting manual 3 0 Settings for boilers Para Parameter name Parameter description Setting Default meter range setting MIN LIQUID FUEL Setting of min liquid fuel boiler temperature 90 C BOILER TEMP Set MIN SOLID FUEL ing of min solid fuel boiler temperature BOILER TEMP MIN HEAT ACCUMULA Setting of min temperature for heat transfer from storage 20 70 C ul CONSUMPTION OF Setting of liquid fuel boiler consumption on 1st stage of the 0 10 nm LIQUID FUEL BOILER burner Unit L h for heating oil or Sm3 h for natural gas BURNER STAGE 1 CONSUMPTION OF Setting of liquid fuel boiler consumption on 2nd stage of the LIQUID FUEL BOILER burner Unit L h for heating oil or Sm3 h for natural gas BURNER STAGE 2 ENERGY SOURCE IN Selection of energy source used to fire liquid fuel boiler 1 HEATING LIQUID FUEL BOILER OIL 2 NATURAL GAS Settings for alternative en
141. r neben dem Symbol oder im Symbol zeigt ob es sich um den ersten oder den zweiten Heizkreis handelt 89 Bedienungsanleitung Symbol Beschreibung R cklauftemperatur in den Kessel Rauchgastemperatur Temperatur des Raums sich die W rmepumpe befindet Brauchwassertemperatur in der Zirkulationsleitung Temperatur der Kollektoren Programmierter Differenzthermostat funktion Temperatur des Festbrennstoffkessels Programmierter Differenz thermostatfunktion Temperatur des Speichers Programmierter Differenzthermostatfunk tion Temperatur des Brauchwassererw rmers Programmierter Differenzthermostatfunktion Temperatur der Umw lzpumpe Programmierter Differenzthermostat funktion Brenner zweite Stufe Umw lzpumpe des Heizkreises R123456789 Status der Steuerausgange des Reglers Relais sind eingeschaltet Status der Steuerausgange des Reglers Relais sind ausgeschaltet vi Sonnenkollektoren Umw lzpumpe Bypass Kesselpumpe F hrende Kesselpumpe ea W rmepumpe pump d Elektroheizk rper p Elektroheizk rper f r die Brauchwassererw rmung o Kessel Umschaltung Brauchwasserw rmung Bedienungsanleitung D I M X SC 280 SSC sc x j xw amp Symbol Beschreibung 0 Betrieb des Ausgangs nach dem Zeitprogramm T1 T2 T3 T8 Temperatur gemessen mit den F hlern T1 T2 T3 T4 T5 T6 T7 T8 TR1 TR2 Temperatur gemessen mit Raumf
142. r with a built in d h w storage tank oil boiler mixing circuit W rmespeicher mit eingebauten Brauchwassererwarmer Fl ssigbrennstoffkessel Mischerheizkreis 4 N Lu e 166 411 WXD20 Heat accumulator oil boiler mixing circuit d h w storage tank W rmespeicher Fl ssigbrennstoffkessel Mischerheizkreis Brauchwassererw rmer ET N ou 2 iei 412 WXD20 Pellet boiler mixing circuit d h w storage tank Pelletkessel Mischerheizkreis Brauchwassererw rmer 4 EN N TER N Gi el 167 413 WXD20 Combined solid fuel oil boiler mixing circuit d h w storage tank Kombikessel Festbrennstoff Ol Mischerheizkreis Brauchwassererw rmer E N l e e 414 WXD20 Combined solid fuel oil boiler heat accumulator mixing circuit d h w storage tank Kombikessel Festbrennstoff Ol W rmespeicher Mischerheizkreis Brauchwassererw rmer 4 a N AMR gt 168 414b WXD20 Solid fuel boiler heat accumulator mixing circuit d h w storage tank Festbrennstoffkessel W rmespeicher Mischerheizkreis
143. range setting 54 1 OUTPUT R5 FUNCTION Setting of output R5 alternative operation mode 1 operation according to selected hydraulic scheme 2 operation according to selected program timer for d h w warming 3 WITHOUT 3 d h w warming without temp difference by warming DIFF with heat pump Service setting manual 48 Para Parameter name Parameter description Setting Default meter range setting HYSTERESIS FOR D H Setting of difference between switch on and switch off point W WARMING domestic hot water warming MAX D H W TEMPE Setting of max allowed d h w temperature If this tempe 50 90 C RATURE rature is exceeded the warming will stop unconditionally D H W OVERHEATING _ Setting of overheating protection for d h w storage tank 0 OFF PROTECTION If maximal d h w temperature by warming with solar 1 COLLEC collectros or solid fuel boiler is exceeded S4 3 controller TORS activates when possible cooling 2 BOILER 1 into collectors 3 BOTH 2 into boiler 3 into collectors and boiler LEGIONELLA ACTIVA Activation of legionella function 0 NO TION 1 YES LEGIONELLA ACTIVATI Setting of day when the legionella protection should ON DAY activate 547 LEGIONELLA ACTIVATI Setting of hour when the legionella protection should ON TIME activate MIN D W TEMP BY Controled heat source oil boiler heat pump electric WARMING WITH SOLID heater
144. rature below which the operation of heat pump is blocked Parameter S6 17 defines outdoor temperature for bivalent operation mode of heat pump When outdoor temperature drops below setted temperature auxiliary secondary heat source is activated if heat pump cannot supply requested temperature Auxiliary heat source is activated with delay when the outdoor temperature is lower as temperature for monovalent operation S6 19 and higher as temperature for bivalent op eration S6 17 Delay time depends on temperature deficit and setting of parameter S5 15 Parameter S6 19 defines minimum outdoor temperature above which the operation of auxiliary heat source is blocked PUMP FOR RETURN PIPE TEMPERATURE INCREASE BYPASS PUMP This option is available for classic liquid fuel boilers and solid fuel boilers with no connec tion to heat accumulator Output RO or R9 can be used to control the bypass pump to increase boiler return temperature Such operation mode is set with parameter S1 11 4 RO or S1 12 5 R9 Install the T1 or T8 sensor in the boiler return pipe before the by pass connection and set parameter S1 4 9 for sensor T1 or S1 5 12 for sensor T8 If return pipe temperature drops below the temperature set by parameter S5 14 the pump is Switched on DOMESTIC HOT WATER D h w warming with liquid fuel boiler Set the required d h w temperature for the inactive time program interval with parameter PA If boiler temperature excee
145. rature limitation by floor RATURE heating Setting is active only if floor sensor is installed and parameter 51 522 MINIMUM STAND PIPE Setting of minimum stand pipe temperature in cooling mode 10 20 TEMPERATURE IN CAUTION Too low stand pipe temperature can cause dewing COOLING MODE of heating bodies and pipelines SHIFT OF TEMPERA Shift of calculated min stand pipe temperature by which the 10 10 C TURE REQUIRED TO mixing valve control will activate ACTIVATE STAND PIPE Negative values mean activation of mixing valve control by CONTROL lower calculated stan pipe temperatures positive values mean activation of mixing valve control by higher calculated stand Pipe temperatures LIMITATION OF Setting of maximal difference between stand pipe and return TEMP DIFFERENCE pipe temperature This way the highest power of heating BETWEEN STAND AND system is limited RETURN PIPE Limitation of difference between stand and return pipe is activated with parameter S1 5 3 CONSTANT STAND Selection of operation with constant stand pipe temperature 0 NO PIPE TEMPERATURE Setting range is 10 140 C 1 YES CAUTION This function deactivates weather compensated control of mixing valve 3 16 CIRCULATION PUMP Setting of circulation pump switch off delay when there is no 0 10 min SWITCH OFF DELAY requirement for heating m S4 Service settings for domestic hot water Para Parameter name Parameter description Setting Default meter
146. rnom meter nung bereich mener Wert EINSCHALTPUNKT VERSCHIEBUNG DER VORLAUFTEM PERATURREGE LUNG DIFFERENZBE SCHRANK ZWI SCHEN VORLAUF UND RUCKLAUF KONSTANTE VOR LAUFTEMPERATUR AUSSCHALTVER ZOGERUNG DER UMWALZPUMPE MINUTEN Mit dieser Einstellung korrigieren wir die minimal erforder 10 10 C liche Vorlauftemperatur um die Mischventil Regulierung einzuschalten Negative Werte bedeuten das ein schalten des Reglers bei niedrigeren Ausgerechneten Vorlauftempe raturen und positiven Werte die Regler ein Schaltung bei H heren ausgerechneten Vorlauftemperaturen Das Einstellen der maximalen erlaubten Differenz zwischen Vorlauf und Rucklauf Auf diese Weise wird die maximale Leistung des Heizkreises begrenzt Differenzbeschrankung wird mit dem Parameter S1 4 3 f r T1 oder S1 5 6 f r T8 aktiviert Die Auswahl ob der Regler mit Konstanter Vorlauftempe ratur arbeiten soll Der Einstellungsbereich der Konstanten Temperatur ist 10 140 C VORSICHT Durch diese Funktion wird die Regelung in Abh ngigkeit von der Au entemperatur aufgehoben Mit der Einstellung bestimmen wir die Ausschaltverz gerung der Umw lzpumpe ein wenn es keine Heizungsanforderung gibt Wartungseinstellungen f r den zweiten Heizkreis Para Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom meter nung bereich mener Wert AUSWIRKUNG DER RAUMTEMPERA TURABWEICHUNG T8 RAUMF HLER EINFLUSS D
147. rt einwandfrei in Abh ngigkeit von der Au entemperatur R cklauflauftemperaturf hler ist nicht angeschlossen oder ist defekt Die Raumheizung funktioniert einwandfrei ohne den Einfluss der R cklauftemperatur F hler des Brauchwassererw rmers sind nicht angeschlossen bzw sind defekt Wenn ein F hler au er Betrieb ist wird nur der zweite F hler vom Regler benutzt Wenn beide F hler au er Betrieb sind schaltet sich die Pumpe zur Brauchwassererw rmung aus Sonnenkollektoren F hler ist nicht angeschlossen bzw ist defekt Die Umw lzpumpe zur Brauchwassererw rmung mittels Sonnenkollektoren schaltet sich aus TABELLE Widerstand der Temperaturf hler Pt1000 o2 35 ts 90 ta 145 1555 10 9631 4100 1305 155 EEN 5 fso 50 faa 144 faeo fini o 100 55 nr to 123 is 16293 5 120 142 Jt i142 1 1648 25 197 80 amp 20 139 fans 190 ree 143 Montageanleitungen MONTAGEANLEITUNG MONTAGE DES REGLERS Der Regler wird in einem trockenen Innenraum montiert Die Montage in unmittelbarer N he von Quellen eines starken elektromagnetischen Feldes ist zu vermeiden Man kann ihn direkt an die Wand oder in eine Standard ffnung 138 x 92 mm am Kessel Montieren WANDMONTAGE Die Wandmontage wird wie folgt ausgef hrt loooocooloooooooD0 0000000000002 g
148. s activated protection of max solar coll ector or solid fuel boiler temperature If solar collector or solid fuel boiler temprature is exceeded circulation pump in solar system will activate although d h w temperature is already reached Setting of maximum solar collectors or solid fuel boiler emperature f solar collector or solid fuel boiler emergency shutdown emperature is exceeded circulation pump will stop unconditionally f the temperature drops bellow the set point value S6 5 he solar pump switches on to prevent freezing in the collectors and pipelines NOTE This setting is suitable only for climates areas where the temperature only occasionally drops bellow the reezing point Setting of temperature by which the collector s frost protection should activate 51 Parameter name Parameter description Setting Default range setting 0 NORMAL 1 INVERTED 70 350 C 70 350 C 50 150 C 20 10 C Service setting manual Para meter Setting if d h w warming with oil boiler and solar collec tors or solid fuel boiler can operate at the same time or oil boiler shall activate with delay after warming with solar collectors or solid fuel boiler has been stopped OPERATION OF LIQUID FUEL BOILER Selection of circuits where oil boiler shall activate with de lay after warming with solar collectors or solid fuel boiler 1 domestic hot water 2 heating circuits 3 domestic hot water and
149. s only available in schemes with two heating circuits User manual 22 BASIC SETTINGS Duration of active display illumination and return to the main menu Intensity of active display illumination Intensity of stand by display illumination Contrast Graphic display of operating hours of the first and second burner stage Graphic display of daily temperatures for the period of past week Detailed graphic display of temperatures for the current day Output operation time counters Special service data USER PARAMETERS General settings T 1P 2 settings for the first heating circuit Settings for the second heating circuit D h w settings Settings for boilers Settings for alternative energy sources 23 User manual SERVICE PARAMETERS Service parameters for boilers Service parameters for alternative energy sources FUNCTION PARAMETERS Parameters for floor drying User manual 24 TEMPERATURE SETTINGS The menu displays the temperatures available by selected hydraulic scheme Select the temperature with buttons and Anew screen with temperatures will open 1 a _ TO 35 0 C I Current value of requested emperature m temperature numerical display Last confirmed value of setting Graphic display of the setting Factory value Setting range Current value of requested temperature Set the requested temperature with buttons and and con
150. s with the display of time program 1 m i IN for the selected day On the top of the screen you will find the field for the selection of day or a group of days into which you wish to copy your time program Select the day or a group of days with buttons and Press the V button to copy 16 20 24 Exit the copying by pressing the 29 button Default settings of time programs The first time program for Switch on Interval room heating and d h w MON FRI 05 00 07 30 13 30 22 00 SAT SUN 7 00 22 00 warming O1 for room heating TI Switeh on interval for room heating and d h Bay EE w warming 2 MON FRI 06 00 22 00 SAT SUN 7 00 23 00 31 User manual BASIC SETTINGS This menu is intended for the setting of language time date and display User language Select the requested user language with buttons and confirm it by pressing the button Exit the setting by pressing the button time and date The exact time and date is set in the following manner Move through individual data with buttons and With the V button select the data you wish to change ET When data begins to flash change it with buttons and 22 01 2011 and confirm it by pressing the V button Exit the setting by pressing the button User manual 32 Display settings The following settings are available Duration of active display illumination an
151. ssel Festbrennstoff Ol 2x Mischerheizkreis Brauchwassererwarmer 423h WXD20 Expansion scheme 2x mixing circuit d h w storage tank Erweiterungsschema 2x Mischerheizkreis Brauchwassererwarmer EI OS Bus v AT 13 CZ 12 GN PE GND 6 GND 180 NOTES NOTIZEN NOTES NOTIZEN 182 1MC060283 2013 Subject to errors changes and improvements without prior notice Wir behalten uns das Recht auf Ver nderungen und Verbesserungen vor Software vl
152. ssererw rmung nach Zeitprogramm Ausschaltintervall Dauerbetrieb der Brauchwassererw rmung Manueller Betrieb SYMBOLE DER BENUTZERFUNKTIONEN Symbol Beschreibung PARTY Modus ECO Modus Urlaubsmodus Einmalige Brauchwassererw rmung Legionellenschutzfunktion Fl ssigbrennstoffkessel blockiert Ausgeschaltet Festbrennstoffkessel Einschaltung Nummer zeigt an ob es sich um das erste oder das zweite Zeitprogramm handelt Bedienungsanleitung 88 Symbol Beschreibung a Automatisches Umschalten auf den Sommer Modus Estrichtrocknung ist eingeschaltet Betrieb mit konstanter Vorlauftemperatur Ferneinschaltung Boost Heizung ist eingeschaltet SYMBOLE ZUR DARSTELLUNG DER TEMPERATUREN UND ANDERER DATEN Symbol Beschreibung E Ist Temperatur B Ausgerechnete Temperatur oder Soll Temperatur O Raumtemperatur Au entemperatur Temperatur des Fl ssigbrennstoffkessels Temperatur des Festbrennstoffkessels D Temperatur des Gaskessels RB Temperatur der W rmequelle gewonnen ber die Bus Verbindung Temperatur des Kombikessels Le duode Ed M MEME und Festbrennstoff Temperatur der Temperatur der W rmequelle F hler in der R ckleitung F hler in der R ckleitung rn Vorlauftemperatur R cklauftemperatur Brauchwassertemperatur NEUE W rmespeichertemperatur Solarkollektortemperatur Estrichtemperatur Die Numme
153. stens 3 mm betragen Alle niederspannungsf hrende Leitungen wie Temperaturf hlerleitungen sind getrennt von netzspannungsf hrenden Leitungen zu verlegen Alle Temperaturf hlerleitungen in das linke Feld und die netzspannungsf hrenden Leitungen ins rechte Feld des Reglers einstecken Relais R6 ist implementiert als Halbleiter Relais f r die Umw lzpumpe Drehzahlregelung Montageanleitungen 146 ANSCHLUSS DER TEMPERATURF HLER Tauchtemperaturf hler Der Tauchtemperaturf hler ist f r die Montage in die H lse des Kessels W rmespeichers Brauchwassererw rmers Sonnekollektoren und anderenorts bestimmt Es wird daf r ge sorgt dass der F hler an den H lsenw nden anliegt Den F hler gegen Herausfallen mit einer Klemme oder Schraube sichern Anlegetemperaturf hler Den Anlegetemperaturf hler an Vorlaufleitung ber die Umw lzpumpe bzw hinter das Mischventil montieren Die Rohrleitung an der ausgesuchten Stelle gut reinigen Den Fuh ler auf die gereinigte Stelle setzen und ihn mit der beigelegten Greiffeder befestigen Au enlufttemperaturf hler Den Au entemperaturf hler an n rdliche oder nordwestliche Fassade ca 2 Meter ber dem Fu boden montieren Die Montage ber den Fenstern oder Luftsch chten und an s dlicher Fassade ist nicht gestattet Zuerst den Schutzdeckel abnehmen und dann die zwei Befestigungsschrauben l sen F h
154. t W RMEPUMPE Die W rmepumpe ist die Hauptquelle bzw prim re W rmeenergiequelle bei den Schemas 419 420 422 422b 422c und 422d Auf dieselbe Art kann die W rmepumpe als prim re Warmequelle auch zu den folgenden Hydraulikschemas hinzugef gt werden 401b 404b 404d 404e 409 409b 410 410b 410c 411 416 416b 416c in 421 Dabei wird die vor handene kontrollierte W rmequelle d h der Ol Gas oder Elektrokessel als alternative bzw sekund re W rmequelle genutzt Mit der Einstellung des Wartungsparameters S4 9 6 kann der Relaisausgang dessen Grundkonfiguration auf die Zirkulation des Sanit rwassers eingestellt ist auf die Steuerung der W rmepumpe programmiert werden Die Funktion der W rmepumpe und der kontrollierten bzw alternativen Warmequelle das hei t des Fl ssigbrennstoffkessels oder des Elektrokessels wird durch die Einstellung der Parameters S6 17 18 in 19 definiert Mit dem Parameter S6 17 wird die minimale Au entemperatur unter welcher der Betrieb der W rmepumpe nicht erlaubt ist bestimmt Mit dem Parameter S6 18 wird die Au entemperatur der bivalenten Betriebsart der W r mepumpe bestimmt Das hei t die alternative W rmequelle bzw die kontrollierte W rme quelle kann erst aktiviert werden nachdem die Au entemperatur unter den angegebenen Wert f llt Wenn die Au entemperatur niedriger als der Punkt der monovalenten Betriebsart und h her als der Punkt der bivalenten Betriebsart ist ist
155. tch off can be increased or decreased with parameters S2 13 and S3 13 At automatic heating switch off a temperature of 4 C is set for stand pipe temperature and the circulation pump is switched off with delay parameters S2 16 and S3 16 Other pump operation modes can be selected with parameters S2 4 and S3 4 Intensive BOOST heating Define time and intensity of intensive BOOST heating which is activated at transition of time program from night to day heating interval with parameters P2 3 P2 4 for the first and P3 3 and P3 4 for the second heating circuit Limitation of AT or power of first heating circuit To limit the maximum power of the heating circuit use the T1 or T8 sensor to measure the return pipe temperature Set the parameter S1 4 3 or S1 5 6 then set the maximum dif ference between stand pipe and return pipe temperature with parameter S2 14 Limitation of AT or power of second heating circuit To limit the maximum power of the heating circuit use the T8 sensor to measure the return pipe temperature Set the parameter S1 5 3 then set the maximum difference be tween stand pipe and return pipe temperature with parameter S3 14 Limitation of return temperature into the boiler Install T1 or T8 sensor into the return pipe into the boiler and set parameter S1 4 9 or S1 5 12 If return pipe temperature drops below the minimum temperature parameter S5 14 the mixing valve will gradually close This action relieves the boi
156. ted circuit temperature Use buttons and to select the one time activation of liquid fuel boiler and activate it by pressing the V button Exit the setting by pressing the button Switch off block of liquid fuel boiler Use this function when you wish to switch off or block liquid fuel boiler and heat only with solid fuel boiler This function does not have an automatic deactivation and must be deacti vated manually Use buttons and to select blocking of liquid fuel boiler and activate it by pressing the V button Exit the setting by pressing the button Ir Start up of solid fuel boiler This function deactivates liquid fuel boiler and is used whenever we wish to start up the solid fuel boiler If the solid fuel boiler does not reach the requested heating temperature in certain period of time the liquid fuel boiler activates again Use buttons and to select the startup of solid fuel boiler and activate it by pressing the V button Exit the setting by pressing the button You can abort all user functions at any time by selecting the X icon 27 User manual ook SEI 2 S U e E OPERATION MODE SELECTION First heating circuit Second heating circuit Domestic hot water Manual operation Switchover between heating and cooling Emissions analysis 0 3 o z o a m o gt z D m I m o m Q o z D I gt z 2 o a
157. temperaturen k lter wird ist die Steilheit zu niedrig und muss h her gesetzt werden Wenn es im Geb ude bei niedrigeren Au entemperaturen w rmer wird ist die Steilheit zu hoch und muss niedriger gesetzt werden Die Schwankungen hoch und niedrig der Steilheit bei der Einstellung sollten nicht gr Ber als 0 1 bis 0 2 Einheiten bei einer Beobachtung sein Der Zeitabstand zwischen zwei Beobachtungen sollte mindestens 24 Stunden oder mehr betragen Wert der Steilheit der Heizkurve im Normalfall Einstellungsbereich Fu boden 0 2 0 8 0 4 1 0 0 8 1 4 Mit der Einstellung der Heizkurve wird der Regler dem zu regulierenden Objekt angepasst Die richtige Einstellung der Heizkurvensteilheit ist f r den optimalen Reglerbetrieb u erst wichtig 113 Wartungsanleitung Heizkurvendiagramm Vorlauftemperatur Au entemperatur Wartungsanleitung 114 WARTUNGSPARAMETER Die Wartungsparameter sind in die Gruppen S1 allgemeine Einstellungen S2 Ein stellungen f r den ersten Heizkreis S3 Einstellungen f r den zweiten Heizkreis S4 Brauchwassereinstellungen S5 Kesseleinstellungen und S6 Einstellungen f r alternati ve Energiequellen eingeteilt Mit den Wartungsparametern kann man zwischen zahlreichen Zusatzfunktionen und Anpassungen im Reglerbetrieb w hlen Wenn im Men die gew nschte Parametergruppe ausgew hlt wird erscheint eine neue Anzeige Parameter ist gesperrt Bezeichnung des
158. tion ern ame Remote heating ctivation u un ee een NEESS NEE Operation of heating systems with two heat sources Setting the minimum RPM for pump RO Differential Controler p ee een Operation modes in cases of sensor Malfunction INSTALLATION MANUAL Gontrollerinstallati n eet Wall ristallatiOn oie itte ER ete to Piin eeh eis Panel installation Electric connection of the controller eem ernennen nenn 69 Connection of temperature SENSOTS enne nnne 70 Room unit DD2 BUS connection of WXD Controllers ens 72 BUS connection to CMP25 2 Controllers nennen ernennen 72 Installation and connection of VT safety 73 Controller E lee EE 74 Sensor simulation and controller operation Test 74 Controller failure and servicing een 74 Technical dala EE 75 Declaration of confokmlty i eiae Here ae 76 Disposal of old electrical and electronic equipment nennen 77 Ke 78 Flydraulic Sschemes E 154 USER MANUAL CONTROLLER DESCRIPTION Ipse y E 1 fa 20 5 zc E89 OA WXD20 1 Graphic display 2 USB connector for connecting personal computer 3 Keypad 4 Programmable key User manual 8 INITIAL CONTROLLER SETUP WXD heating controllers are equippe
159. tion wird die Regelung in Abh ngigkeit von der Au entemperatur aufgehoben Wartungsanleitung 122 Para Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom meter nung bereich mener Wert AUSSCHALTVER Mit der Einstellung bestimmen wir die Ausschaltverz gerung 0 10 Min Z GERUNG DER der Umw lzpumpe ein wenn es keine Heizungsanforderung UMW LZPUMPE gibt Wartungseinstellungen f r das Brauchwasser Para Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom meter nung bereich mener Wert FUNKTION DES AUS Mit der Einstellung kann eines der zus tzlichen Funktions 1 LAUT GANGS R5 arten des Relaisausgangs R5 gew hlt werden 1 Funktioniert gem des ausgew hlten Hydrauliksche 2 ZEITPRO matas GAMM 2 Arbeitet nach ausgew hltem Zeitprogramm f r Erw r 3 OHNE DIFF mung der Brauchwasser 3 Steuerung der Pumpe f r die Brauchwasser ohne Be r cksichtigung der Differenzbedingung z B bei beheizen der B W mit W rmepumpe HYSTERESE F R Eingestellt wird die Temperaturdifferenz zwischen BRAUCHWASSER Einschalt und Ausschaltpunkt zur Erw rmung der W RMUNG Brauchwasser MAXIMALE TEMPERA Mit der Einstellung wird die maximale erlaubte Temperatur 50 90 C TUR DES BRAUCH der Brauchwasser bestimmt Wird diese berschritten WASSERS wird die Beheizung bedingungslos ausgeschalten LEGIONELLEN Mit der Funktion wird die Schutzfunktion gegen Legionel 0
160. tions in force when performing installations WICHTIG ACHTUNG Die Installationsschemas verweisen auf das Betriebsprinzip und verfugen nicht Uber alle Hilfs oder Sicherheitselemente Bei der Montage die g ltigen Vorschriften beachten LEGEND LEGENDE possibility of free programming of differential controller ATI M glichkeit der Frei programmierung von Differenzregler AA E valve gate with open flow when the actuator is in base position Markiert den Anschluss der offen in der Ausgangsposition des Umschaltventils ist Switching valves must be in primary position without control voltage swit ched to the solid fuel boiler or heat accumulator Die Umschaltventile miissen in der Ausgangsposition ohne Schaltspannung auf den Festbrennstoffkessel oder den Speicher geschaltet sein 154 401 WXD10B WXD10 WXD20 Oil boiler mixing circuit d h w storage tank Fl ssigbrennstoffkessel Mischerheizkreis Brauchwassererwarmer T2 HORA 401b WXD10B WXD10 WXD20 Heat accumulator mixing circuit d h w storage tank Warmespeicher Mischerheizkreis Brauchwassererwarmer T2 SEHR T4 7 4 IGND YL W R3 ba 155 401c WXD10B WXD10 WXD20 Solid fuel boiler mixing circuit d h w storage tank Festbrennstoffkessel Mischerheizkreis Brauchwassererw rmer zd N i M t F i e
161. tivated parameter S4 4 59 Service setting manual Pump kick function for solar collector Pump kick function for solar collector pump is set with parameter S6 8 1 If collector temperature is higher as minimum collector temperature the pump is activated each 15 minutes for 10 seconds This way a realistic collector temperature is acquired This setting is used in case if collector sensor isn t mounted directly into the collector body DOMESTIC HOT WATER CIRCULATION The d h w circulation pump is operating according to the time program for the d h w circulation parameter P4 7 The pump is operating with running and standby intervals which are set with parameters P4 8 and P4 9 D h w circulation on output RO or R9 With parameter setting S1 11 2 RO or S1 12 3 R9 output can be programmed for the activation of d h w circulation with temperature sensor D h w circulation with the use of sensor If T1 or T8 sensor is free it can be used to activate the d h w circulation with parameter S1 4 4 for sensor T1 or S1 5 7 for sensor T8 The sensor needs to be installed on the exit pipe from the d h w storage tank hot pipe Whenever an immediate temperature rise for at least 5 K is detected the d h w circula tion pump is switched on for the time set with parameter P4 8 D h w circulation with flow switch If T1 or T8 sensor is free it can be used to activate the d h w circulation with a flow Switch para
162. to immersion tube in boiler heat accumula tor d h w storage tank solar collectors or elsewhere Ensure proper contact between sensor and tube Secure the sensor with a fastener or a screw Surface sensor Install the surface sensor onto the stand pipe above the bypass pump or after the mixing valve Clean the selected spot on the pipe first Place the sensor onto the cleaned spot and secure it with the enclosed clip spring Outdoor temperature sensor Install the outdoor temperature sensor onto the facade facing north or north west approxi mately 2 m above ground Installation above the windows vents or on the facade facing south is not allowed First remove the protective cover and unscrew two screws from the cover Use the en closed wall screw to fix the sensor to the selected spot Feed the cable into the sensor through cable inlet at the bottom side and connect it Room temperature sensor Install the room temperature sensor onto an indoor wall in a living area where is not sunlit and enough distant from sources of heat and wind Remove the cover and screw the base onto the selected spot approximately 1 5 metres above ground You can also install it onto wall box or directly onto a wall A 2 wire signal cable is required for electrical connection If there are thermostatic valves installed onto radiators in the room where room unit is located the thermostatic valves have to be fully opened If room sensor is connected to terminal
163. tur schon erreicht ist Einstellung der Maximalen Kollektortemperatur Wenn die Sonnenkollektoren oder der Festbrennstoffkes sel die eingestellte Temperatur berschreiten schaltet sich die Umw lzpumpe bedingungslos ab 126 70 350 C 70 350 C 50 150 C Wartungseinstellungen f r alternative Energiequellen Para Parameterbezeich Beschreibung des Parameters meter nung Einstellungs bereich 90 290 C 120 350 C bernom mener Wert Para meter FROSTSCHUTZ F R DIE KOLLEKTOREN ARBEITSWEISE DES FLUSSIGBRENN STOFFKESSELS 567 HEIZKREISSE MIT VERZ GERTEM EINSCHALTEN DES FL SSIGBRENN STOFFKESSEL IMPULZ EINSCHAL TUNG DER PUMPE ROHRENKOLLEK TOREN DIE TEMPERATUR DER KOLLEKTOREN F R FROSTSCHUTZ BER CKSICHTIGUNG DER MINIMALEN TEMPERATUR DER KOLLEKTOREN ODER FESTBRENNSTOFF KESSEL BETRIEBSART DER UMV LZPUMPE DER KOLLEKTOREN ODER DES FESTBREN STOFFKESSELS MINIMALER BE TRIEBSGRAD DER RPM REGELUNG ZEIT DER MAXIMA LEN DREHZAHL DER PUMPE F R KOLLEKTOREN ODER FESTBRENNSTOFF KESSEL Parameterbezeich Beschreibung des Parameters Einstellungs Ubernom nung bereich mener Wert 0 NEIN 1 JA Wenn die Temperatur unter den eingestellten Wert S6 5 fallt wird die Solarpumpe eingeschaltet um das Zufrieren der Sonnenkollektoren und Rohrleitungen zu verhindern BEMERKUNG Diese Einstellung ist nur f r die Gebiete an denen die Temperatur nur z
164. uchwasserzirkulation auf dem Ausgang RO oder R9 Der Ausgang RO oder R9 kann f r die Brauchwasserzirkulation mit der Einstellung des Parameters S1 11 2 f r RO oder S1 12 3 f r R9 programmiert werden Brauchwasserzirkulation mit Verwendung eines F hlers Wenn der T1 oder T8 F hler frei zur Verf gung steht kann er mit der Einstellung des Parameters S1 4 4 f r T1 oder S1 5 7 f r T2 f r die Aktivierung der Brauchwasserzir kulation mit Temperaturf hler programmiert werden Der F hler wird an das Austrittsrohr Warmleitung aus dem Brauchwassererw rmer mon tiert Wenn der F hler einen pl tzlichen Temperaturanstieg um mindestens 5 K wahrnimmt wird f r 5 Minuten die Zirkulationspumpe f r das Brauchwasser eingeschaltet Brauchwasserzirkulation mit Durchflussschalter Wenn der T1 oder T8 F hler frei zur Verf gung steht kann er mit der Einstellung des Parameters S1 4 5 f r T1 oder S1 5 8 f r T2 f r die Aktivierung der Brauchwasserzir kulation mit Durchflussschalter programmiert werden Der F hler wird in das Austrittsrohr Warmleitung aus dem Brauchwassererw rmer mon tiert Wenn der Durchflussschalter sich schlie t wird f r 5 Minuten die Zirkulationspumpe f r das Brauchwasser eingeschaltet FERNEINSCHALTUNG DER HEIZUNG Die Einstellung des Parameters S1 6 1 erm glicht eine Ferneinschaltung der Raumhei zung und Brauchwassererw rmung mit Hilfe des telefongesteuerten Schalters f r die Ferneinschaltung Tele
165. um outdoor temperature for system with OUTDOOR TEMP FOR heat pump and other heat source above which solely MONOVALENT OPERATI heat pump operation is allowed ON MODE PARAMETERS FOR FLOOR DRYING Group F1 contains the parameters for the setting of floor drying The procedure for F parameters setting is the same as the procedure for service settings see 41 dd Table with descriptions of parameters Para Parameter name Setting range Default meter setting F1 1 FLOOR DRYING 0 NO 1 CIRCUIT 1 2 CIRCUIT 2 3 CIRCUIT 1 amp 2 INTERVAL 1 DURATION 1 15 days 3 NTERVAL 1 START TEMPERATURE A 5 F1 F1 F1 F1 F1 T 10 60 C SE 1 1 C C EW GENE FAS Era Fis EW PER F1 11_ INTERVAL 4 DURATION 15 days F1 12__ INTERVAL 4 START TEMPERATURE F1 13 INTERVAL 4 END TEMPERATURE 10 60 53 Service setting manual Floor drying profile default setting c F12 o m5 F1 8 E sii E a I luere E Ae eegenen 20 e nn en KE een 20 25 30 Days o u e DEFAULT SETTINGS The menu contains the tools to help you set the controller RESET 6 RESET OF CONTROLLER PARAMETERS Resets all parameter settings P1 P2 P4 P5 P6 S1 except 51 1 52 S3 54 S5 S6 and F to factory set values RESET OF TIME PROGRAMS Deletes the set time programs and retrieves factory set time programs RESET
166. um tem perature of solar collectors parameter S6 1 and S6 2 d h w warming is allowed up to the maximum d h w temperature parameter S4 3 D h w warming is switched off unconditionally if the d h w temperature exceeds the maximum temperature parameter S4 3 or if solar collectors temperature exceeds the maximum temperature parameter S6 3 When d h w is warmed with solar collectors you can set the liquid fuel boiler operation mode with parameter S6 6 S6 6 1 simultaneous operation of both heat sources S6 6 0 600 the boiler will be switches on with set delay after deactivation of the solar System Parameter value sets minutes of delay D h w warming with an electric heater You can reprogram the output to control the electric heater for d h w warming by setting the parameter 81 1123 or S1 12 4 D h w will be warmed up to the requested temperature according to the 2nd time program for d h w warming To control the electric heating body a power relay and a thermal fuse must be connected Priority of d h w warming over room heating With parameters P4 2 and P4 3 you can set the priority of d h w warming over room heat ing By direct heating circuit is suggested to set priority to d h w warming Return cooling of domestic hot water Recooling If d h w exceeds with the maximum temperature parameter S4 3 a cooling of the d h w into the boiler or into the solar collectors can be ac
167. ur Verf gung Bedienungsanleitung 94 BETRIEBSART F R DEN ZWEITEN HEIZKREIS Betrieb nach dem ausgew hlten Zeitprogramm Soll Raumtempera tur wird am Regler oder an der Raumeinheit eingestellt Betrieb nach der Tagestemperatur Soll Raumtemperatur wird am Regler eingestellt Betrieb nach der Nachttemperatur Soll Raumtemperatur wird am Regler eingestellt Aus Erstes Zeitprogramm Zweites Zeitprogramm ZEITPROGRAMM F R DEN ZWEITEN HEIZKREIS Erstes Zeitprogramm Zweites Zeitprogramm Erstes Zeitprogramm Zweites Zeitprogramm Einstellung steht nur bei Schemen mit zwei Heizkreisen zur Verf gung 95 Bedienungsanleitung GRUNDEINSTELLUNGEN DISPLAYEINSTELLUNG Dauer der aktiven Beleuchtung des Displays und des automatischen Verlassens des Men s Intensit t der aktiven Displaybeleuchtung Intensit t der inaktiven Displaybeleuchtung Kontrast Graphische Darstellung der Temperaturen nach Tagen f r die letzte Woche Detaillierte graphische Darstellung der Temperaturen f r den laufenden Tag Bedienungsanleitung 96 WARTUNGSPARAMETER 97 Bedienungsanleitung TEMPERATUREINSTELLUNG Im Men sind nur die Temperaturen angezeigt bei denen man beim ausgewahltem Hyd raulikschema die Soll Temperatur einstellen kann Mit den Tasten und V w hlen wir die gew nschte Temperatur aus Die Anzeige zur Einstellung der Soll Temperatur erscheint ale o Aktueller Wert der Soll Tem
168. warm G1 D oder eines anderen Ger ts mit einem potentiell freien Steuerschalter Wenn am Eingang T1 T6 oder T8 ein Kurzschluss festgestellt wird schal tet der Regler die Raumheizung auf Soll Tagestemperatur und Brauchwassererw mung ein Bei einer BUS Verbindung von mehreren Reglern kann mit dem Parameter S1 8 bestimmt werden ob die Ferneinschaltung f r den ersten Regler auch f r die anderen Regler be r cksichtigt werden soll FUNKTION DER HEIZSYSTEME BEI ZWEI W RMEQUELLEN Der KSF Pro Regler erm glichen eine vollautomatisierte Funktion der Heizsysteme mit zwei Warmequellen zum Beispiel mit Festbrennstoffkessel und Fl ssigbrennstoffkessel Die Systeme k nnen mit einem W rmespeicher ausgestattet sein oder nicht Der Hydrau likanschluss zweier W rmequellen kann parallel oder hintereinander geschaltet sein Bei einer Parallelschaltung wird die eine oder die andere W rmequelle benutzt w hrend bei einer Hintereinanderschaltung beide Quellen gleichzeitig benutzt werden k nnen Umschaltdiagramm zwischen zwei W rmequellen 137 Wartungsanleitung Temperatur 2 1 LEGENDE A Fl ssigbrennstoffkessel Warmequelle A B Festbrennstoffkessel oder W rmespeicher W rmequelle B PT Umschalttemperatur Umschaltung von Fl ssigbrennstoffkessel A auf Festbrennstoffkessel oder W rmespeicher B Wenn die Temperatur der W rmequelle B die Umschalttemperatur PT
169. ys angezeigt F r das Umschalten zwischen den Heizkreisen und dem Display mit der Anzeige des Hydraulikschemas verwendet man die Taste SD Um die Temperatur und andere Daten zu berpr fen benutzt man die Tasten und Die Anzahl der F hler und anderer Daten die auf dem Display zu sehen sind h ngt vom ausgew hlten Hydraulikschema und den Reglereinstellungen ab Wenn Sie w nschen dass nach dem Gebrauch der Tastatur eine beliebige Angabe erneut auf dem Display erscheint suchen Sie die Angabe mit der Taste und best tigen Sie sie indem Sie die Taste 2 Sekunden ge dr ckt halten Wenn die Taste SD f r 2 Sekunden gedr ckt bleibt wird die Temperatur anzeige von einzeilig auf zweizeilig oder umgekehrt ver ndert Bei einer zweizeiligen Temperaturanzeige ist in der ersten Zeile die gemessene Tem peratur und in der zweiten die gew nschte oder die errechnete Temperatur angegeben 87 Bedienungsanleitung BESCHREIBUNG DER ANGEZEIGTEN SYMBOLE AM DISPLAY SYMBOLE DER HEIZKREISE Beschreibung Erster Mischerheizkreis Zweiter Direkt oder Mischerheizkreis Brauchwassererw rmung SYMBOLE F R DARSTELLUNG DER BETRIEBSART Beschreibung Raumheizung Raumk hlung Betrieb nach Zeitprogramm Tagesintervall Betrieb nach Zeitprogramm Nachtintervall Betrieb nach Soll Tagestemperatur Betrieb nach Soll Nachttemperatur Brauchwassererw rmung nach Zeitprogramm Einschaltintervall ON Brauchwa
170. zahl der Pumpe vergr ert werden musste muss die Anfangsstufe des Pumpenbetriebs in den Parameter S6 11 Wartungsanleitung 140 DIFFERENZREGLER Der KSF Pro Regler sind mit einem selbst ndigen Differenzregler ausgestattet Dieser wird mit dem Parameter S1 12 1 oder S1 2 2 f r Festbrennstoffkessel aktiviert Die Differenz regler Funktion ist bei Hydraulikschemen bei denen R9 T7 und T8 nicht besetzt sind m glich Der R9 Ausgang ist mit einem opto Triac ausgef hrt und erm glicht die Regulation der Umw lzpumpen Umdrehungen RPM BEISPIEL DER NUTZUNG DES DIFFERENZREGLERS F R DIE SONNENKOLLEKTOREN Notwendige Parameter Einstellung 1 12 1 6 13 1 Bild 1 Brauchwassererwarmer Notwendige Parameter Einstellung 1 12 1 56 13 2 Bild 2 W rmespeicher 141 Montageanleitungen BEISPIEL DER NUTZUNG DES DIFFERENZREGLERS F R DEN FESTBRENNSTOFFKESSEL Notwendige Parameter Einstellung 1 12 2 6 13 1 Bild 1 Brauchwassererwarmer Notwendige Parameter Einstellung 1 12 2 56 13 2 Bild 2 Warmespeicher 411 413 416 416b 416c 417 418 419 420 421 422 422b 422c 422d 423e 423f 423g und 423h aktiviert werden Die Schemas 404 404b 404c 404d 404e 404f 405 406 und 407b beinhalten schon einen Solarsystem Differenzregler