Home
SPECIAL FUNCTIONS DESCRIPTION
Contents
1. K O O E E gt gt ig Ss S5 el c eo q TI I gt d TI I U v UN Q d Dh 2 000 Gu cu e This function calculates material density basing on its weight in air and in liquid of known density using the formula below eee A R where m weigh in air m weight in water pL density of liquid Default liquid density is pL 1g em distilled water When using liquid other than distilled water choose F hYd and use F 2 option to enter its density according to its temperature To enter the value use the following keys gt 0 digit increase E decimal point gt T lt next digit MENU end The measurement is performed in three phases measurement in air measurement in liquid hanger weighing To read density determination result enter F hYd function menu and use FP option Press gt key to display successive measurement number Press gt key again to display density measurement result and to send the density value to the printer The balance is now ready for the next density determination SPECIAL FUNCTIONS DESCRIPTION 19 To print a density determination report after all necessary measurements connect a printer to the balance Date MEASUREMENT No WEIGHT in air WEIGHT in liquid HANGER WEIGHT LOAD DENSITY LIQUID DENSITY Operation seque
2. v b 5 gt 04 v b 50 MENU v y TL 2 gt T7e 100 MENU S4 0 gt Te y h Press MENU key and choose F thr with gt T lt key The following options are displayed F 0 deactivate the function F 1 activate the function F P check current threshold values use E gt to display successive values F t Relays socket mode 0 exit 1 Batching mode 2 Indication mode Choose F 0 option with gt 7 lt key Following options are displayed SEt 0 start the function with the excess signalisation SEt 1 set lower threshold value SEt 2 set lower threshold value SEt 3 set zero excess signalisation Set the lower and the upper threshold values with the following keys 0 lt digit increase gt decimal point gt T lt next digit MENU end To start checkweighing function use Set 0 option To change Relays socket mode use F t option Default option is Indication To leave the function press MENU key and choose thr and F 0 options 14 SPECIAL FUNCTIONS DESCRIPTION Notes When necessary use SEt 3 option to set the zero threshold value indications below this value are regarded as unloaded balance Relays connection diagram shield Relays output is the open collector transoptor output with load capacity 100mA 24V Transmitter inputs must be protected with diodes e g 1N4148 It is advised to use MS3K P electronic bo
3. C This function allows precise animals weighing i rE gt gt S O 4 Ka d D Tl a y Gi S qe lt 25g Important notes 1 The load less than Min is not averaged Press MENU key When LOC function is displayed press 7 lt key Function options F 0 leave the function F 1 automatic weighing after loading the balance F 2 the measurement initiated manually with L gt key For automatic weighing press Ale key when F is displayed Tare the balance when necessary and place the animal on the pan Wait until the weighing result is averaged the indication blinks Final result is displayed on the display and send via serial port to computer or printer Remove the animal from the pan the result is displayed for 30s and then the balance starts the new measurement 2 In case placing the animal takes more than 5s it is advised to use F 2 option manual weighing with E key 10 SPECIAL FUNCTIONS DESCRIPTION 8 Maximum value UP This function enables to display the maximum value from the series of weighing 09 MENU vob F UP gt T F 0 R F 1 gt T v 1g y 10g v Make sure the balance displays zero indication before starting measurements Enter the function menu with MENU key and choose F UP func
4. F 1 activate date printout E key F 2 change date and time The example at the left presents how to set current date and time with F 2 option Change successive numbers using gt 0 lt key To move to the next position use gt T lt key Once current date and time is set activate it with F option Time format h gg mm gg hour m minute Date format d mm dd m month d day Year format r rr r two last digits of a year CH SPECIAL FUNCTIONS DESCRIPTION 4 Formulation function SUS Dade Tl 4 a rH ra crm Cra d A PIII e NE GA a K ag Vv ab This function allows separate weighing of several ingredients in one container with a possibility to control aggregated sum of all weighed components Function options F 0 leave the function to read aggregated weight F 1 start recipe formulation F 2 return to formulation Before weighing each of successive recipe ingredients A B C etc make sure the balance displays zero indication or simply tare the balance with gt T lt key To display aggregated sum of series of measurements press MENU key choose SU function and use F 0 option Aggregated weight of the recipe is displayed when SUM indicator is lit Whilst SUM indicator is displayed it is possible to return to the previous formula with F 2 option To finish for
5. ae E SPECIAL FUNCTIONS DESCRIPTION USER MANUAL COMPLEMENT B series File EO F 006 01 08 B 41_3 LCD GB v 4 SPECIAL FUNCTIONS DESCRIPTION Contents a oa 3 2 ARCYS ANG ICAO Sireen a nile eleiea alana 4 3 Date and time O da 5 E o A toc iisl ala cutd piescalhs cencad dal cael casa ao 6 5 Average calculation del 7 6 Percentage weighing EE 8 T Animal EE 9 EE 10 9 Anti disturbance bo 11 IN htes boca lates We cite aol edad ae cl abhi Ge date as 12 11 Total weight function OA id 16 12 Density determination hYdro ee 18 13 Function Menu customisation E ACTA 20 SPECIAL FUNCTIONS DESCRIPTION 3 1 Basic information Beside basic measuring functions all balances are equipped with the set of special user functions Standard balance features the following functions a basic set of special functions including pieces counting autozero serial port working mode setting serial port parameters setting constant tare calibration options On customers request balances may be equipped with a additional set of special functions including percentage weighing formulation animal weighing maximum value anti stroke filter checkweighing paper substance determination total weight function liquid and solids density determination O oOo D This brochure describe s the functions not explained in user manual i e additional functions set Functions available with special ba
6. ard sold separately consisting of RMO96P transmitters with DC24V input voltage and AC250V 3A output Important notes After switching the balance on both thresholds are set as maximum values When selecting upper threshold value pay attention that its value is not greater than the lower threshold value SPECIAL FUNCTIONS DESCRIPTION 15 16 SPECIAL FUNCTIONS DESCRIPTION 11 Total weight function totAL The function enables to calculate total weight of series of measurements greater than the balance capacity Og MENU v bh F tot STe v F 1 gt T v 10g E Y Og WwW 20g E v b 0g MENU y F tot E y F P gt T v TAL 30g E v b 2 E XY la 15g Cc Y h Og To enter the function press MENU key and choose F tot option with gt 7 lt key The following options are displayed F P report printout without clearing the adding register F 0 report printout with clearing the adding register F 1 report printout measurement F 2 report printout disabled after each Press T lt key when F is displayed Place successive samples on the pan and press gt after each measurement to store the value in the adding register To dis
7. ed Date Time MEASUREMENTS No AVERAGE VALUE To leave the function press MENU key choose F SrE function and select F 0 option SPECIAL FUNCTIONS DESCRIPTION 6 Percentage weighing F Pro 100 50 Og y MEU D gt D gt T lt y 100 00 50 00 This function enables to display welghing result as a percentage of a reference sample A measurement is performed in two phases first phase weighing a reference sample second phase measuring specific sample as a percentage of the reference sample Weighing result is displayed in different format depending on the reference sample weight value For values of 0 3 5 of weighing range the format is 100 0 for values 3 5 35 it is 100 00 and 35 100 100 00 The function has the following options F 0 disables the function F I stores current indication as 100 and activates percentage welghing F 2 activates percentage weighing with the previous reference sample value 99 sign is replaced with indicator Note 1 Err 3 communicate signalises that 100 value is smaller then 0 5 Min or not entered see F 1 2 When the function is activated gt T lt key function does not change SPECIAL FUNCTIONS DESCRIPTION 9 7 Animal weighing LO
8. lance program with limited use of other functions SPECIAL FUNCTIONS DESCRIPTION 2 Keys and indicators key O key HR key B G key MENU key gt 0 lt key L key O indicator 0 lt indicator Ge indicator NET indicator MODE bar indicator indicator OFF indicator B G indicator pcs switch on switch off standby increased indication resolution gross weight indication switch special functions menu zero print out switch on switch off standby zero indicator result stabilisation indicator net weight indicator indication with subtracted tare special function mode indicator total load indicator graduated 0 100 standby switched off with key gross weigh indicator after pressing B G key number of pieces To enter numeric values use the following keys gt 0 lt digit increase decimal point Ale next digit MENU end SPECIAL FUNCTIONS DESCRIPTION 5 3 Date and time setting dAtE MENU b Y F dAt GT v b F 0 K F 2 ste y b h13 18 at v b gt ba hy h13 18 T MY b h13 19 a d04 05 r 06 T 4 This function enables to set current date and time of internal balance clock and enable disable date and time on weighing result printouts Options F 0 deactivate date printout
9. mulation and to remove SUM indicator press gt T key Notes If o indication is displayed at the left of the display SU function is active SPECIAL FUNCTIONS DESCRIPTION 7 5 Average calculation SrE This function enables to calculate average value of series of measurements During measurements successive values are registered automatically after result stabilisation Og MENU v F 9E gt T v F 1 gt Te S 10g y Og y a 20g y Og E vob 27 E h 15g B ob Og Press MENU key and choose F SrE function with gt T key The following options appear F 0 exit F 1 average calculation Select F option The balance is now registering each stable result for average value calculation Pay attention that the value is registered only when the result is stable Remove the load only after communicate is displayed The balance registers the results above Min balance value only The number of successive measurements is limited to 9999 Press L key several times to display average calculation information in the sequence given below number of measurements n average value Press L key for the third time to continue measurements If the printer is connected the following report is print
10. nce weighing in air and in liquid for below balance weighing Phase I measurement in air Phase II measurement in liquid En q 20 SPECIAL FUNCTIONS DESCRIPTION 13 Function Menu customisation F ACt MENU y b F ACt Ex v F1 AUt 4 Z FS pF v b F 0 VY F 1 PT This function enables to select special functions that will be displayed after pressing MENU key Easy access to the most useful functions will shorten operation time and make work more comfortable Operation sequence shown on the picture presents how to add RS232C parameters setting function F rS to the Function Menu To remove a function from the Function Menu choose F 0 in the last operation
11. play current results enter F tot function menu and choose F P option The results are display in the following order total weight number of registered measurements n average value Press L gt key twice To continue series of measurements press gt key for the third time SPECIAL FUNCTIONS DESCRIPTION 17 To leave the function with clearing the adding register enter F tot function menu and choose F 0 option When connected to a printer the balance prints the communicate informing about clearing the register The sample check for each measurement Date Time measurement no weight measurement no weight Report printout sample Date Time TOTAL WEIGHT NUMBER OF SAMPLES AVERAGE VALUE Note When the balance has not an internal clock Date and Time do not appear on printout Maximum number of measurements 99 999 Maximum total load 99 999 000d The weighing unit of the aggregated value from the register total is the same as the weighing unit stated on the keypad or is 1000 times greater signalised with o indicator at the left of the display If the registered value is too big to be displayed E communicate appears on the display If the number of series is too high to be displayed Errl communicate appears on the display 18 SPECIAL FUNCTIONS DESCRIPTION 12 Density determination hYdro Og MENU vt F hYd T Eg
12. th MIN OK and MAX indicators and sound signal generated when threshold values are exceeded If comparison result is smaller than lower threshold the balance displays MIN between threshold values the balance displays OK with the shot sound signal when exceeding the threshold greater than upper threshold the balance displays MAX with the long sound signal when exceeding the threshold The checkweighing results can be use to control external optical indicator Indication mode or batching devices Batching mode Standard balance is set for cooperation with the external indicator Threshold comparison results appear on P1 P3 Relays socket output pins as a short circuit state Output state charts increasing load External optical indicator Dosing P1 t P1 zero thr l treshold l P2 P2 thr thr Il P3 P3 thr Il zero treshold During dosing optional short circuit pulses lasting for 0 5s appear on P1 I threshold and P2 II threshold outputs and for P3 output zero threshold short circuit state for the indication below zero threshold SPECIAL FUNCTIONS DESCRIPTION 13 Og MENU s b F thr gt T lt v b F 0 NY F 1 gt Te v b H 1 Tor v b E O
13. tion The displayed indication is the highest value from the series of measurements Press gt T key to zero the indication Note Autozero function and the stabilisation indicator are deactivated when UP function is active The indication is the result of continuous averaging of 5 measurements SPECIAL FUNCTIONS DESCRIPTION 11 9 Anti disturbance filter FIL Og MENU s b F AL Lon v F 0 S F 1 So F 2 F 4 gt T v Filter 0 g This function activates digital filter of chosen intensity which reduces the influence of mechanical vibrations air blasts base vibrations on measurement result Using the filter is necessary for accurate people or animal weighing Press MENU key and choose F FIL with gt T lt key The following options appears F 0 filter deactivated F 1 filter I weak F 2 filter II average F 3 filter III intense F 4 filter IV very intense Choose the filter of desired intensity the balance is now operating with selected filter To return to normal work deactivate the filter enter F FIL menu and choose F 0 option 12 SPECIAL FUNCTIONS DESCRIPTION 10 Checkweighing thr This function compares weighing result with two reference values lower and upper threshold The balance signalises comparison result wi
Download Pdf Manuals