Home

User manual CuroCell® AREA Zone C5

image

Contents

1. Care of sweden Supporting Life User manual 2015 11 23 CuroCell AREA Zone C5 Self adjusting pressure care mattress User manual item number 95 001308 31345 054353 CE Contents Important safety precautions Introduction Product description Instruction for use Cleaning and reconditioning Storage Troubleshooting Technical description Spare parts Accessories Warranty Other information Own notes O wo N A W 10 10 10 12 12 13 13 14 IMPORTANT SAFETY PRECAUTIONS Read all instructions prior to use WARNING 1 The product must only be used for its intended purpose as described in this manual The product may not be combined assembled or repaired with other parts accessories or spare parts other than those described in this manual or other documentation from Care of Sweden 2 The mattress are protected with a hygiene cover Please try to avoid the simultaneous use of multiple hygiene cover with this mattress Because of the risk vapour permeable can be destroyed 3 DO NOT USE in the vicinity of or in contact with fire sources hot surfaces such as fire burning cigarettes or hot lamps Although the product has undergone fire testing it could become damaged if it comes into contact with fire sources 4 Position and use the product in a manner that prevents it from becoming trapped or damaged NOTE Be particularly aware of trapping damage when using bed rails 5 Always make sure the mattress
2. General e The main purpose of the training is not to reach high speed but to learn the correct technique Training covers e Because of the heavy strain on the equipment when evacuating always check the seams and handles at the end of training We recommend that equipment used for training is marked with Training equipment and is only used for this purpose Explanations e If the Velcro straps are not used there is a risk of the patient sliding rolling down from the mattress e Pulling at the foot end reduces the strain on the puller which means faster and safer evacuation is possible e Pulling in the stairs is the most difficult part of the evacuation and should be practiced extra carefully e The arms of the patient shall be inside of the Velcro straps This way reduces the risk of the user grabbing hold to something out of fear NOTE There is a difference in maximum user weight between use of the mattress and use of the Evac function Please read section 1 2 for more information arza To ensure proper function of the Evac cover it is important to regularly check the quality of the mattress Check for damages that could cause 0 130kg problems when evacuating ZEB RB BRR RRR Ree eee ey Fee BP BB BBR 6 2 Product description Because of its unique construction combining foam and air this mattress provides high user comfort as well as a solution for pressure care without the need for external pump or electric
3. 0 130kg Recommended user weight when using Evac Q pm O 5 Machine wash at 95 C Class Il equipment Double Insulated kami 3 Symbol Definitions Manufacturer GROY anna ARo 7 O 4nna Group of function Recommended user weight Counteract shear force lt 1 Chlorine ZX Do not iron ype BF T i RESISTANT XXXX XX XX Year Month Day CE CE marked acc to MDD 93 42 EEC Category Patient information category pa Heel function Q umble dry Ry Do not dry clean IP__ IP class Ingress Protection Rating Foot placement ey Y ue Recycling Directly on bed base TX Do not wash Rs Do not tumble dry Temperature range The mattress should only be Resistance to ignition used lying in the lengthwise Conforms to BS 7177 2008 direction on the mattress for medium hazard 11 8 Spare parts Cover Stone top part welded grey Art No CC 925750 CC 925751 CC 925761 CC 925752 CC 925753 CC 925762 CC 925754 CC 925755 CC 925763 CC 925756 CC 925757 CC 925766 CC 925758 CC 925759 CC 925757 Art no CC 900050 If other spare parts are needed please contact Care of Sweden or your local dealer for further assistance Size 80x200 cm 80x210 cm 80x220 cm 85x200 cm 85x210 cm 85x220 cm 90x200 cm 90x210 cm 90x220 cm 105x200 cm 105x210 cm 105x220 cm 120x200 c
4. BSI Clean the affected area with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 4 2 Foam core Clean the affected area with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Press out the water carefully Let the foam core dry in a warm ventilated area without direct exposure of sunlight The foam core needs to be completely dry before it is used again 4 3 Air cells 1 Remove the covers See instructions in chapter 4 1 for cleaning covers 2 Carefully remove the air cells from the foam core Remove the cell holder from the cells 3 Place the air cells and the tubes on a clean area which is suitable for washing 4 Wipe off the cells all tubes with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 5 Replace the cells into the cell holder Place the air cells back into the foam core Check that all the tubes and connectors are secure and tight before closing the cover 6 Wipe off work surfaces with alcohol based disinfectant cleaner intended for this purpose If cells for any reason have loosened from the tubes these must be replaced according to drawing in chapter 2 1 5 Storage Store the mattress on a flat surface or carefully rolled folded w
5. has the right size 6 The hygiene cover does not allow liquid or air to penetrate but is vapor permeable Make sure that the patient is positioned correctly to avoid the risk of suffocation 7 Prevent damage to the hygiene cover from sharp objects 8 Ifthe cover are supplied with handles on the long sides theses handles are only to be used for lifting and moving the mattress itself All other use will be at your own responsibility and is not covered by the product warranty 1 Introduction f Always read the user manual prior to use 1 1 General information This CuroCell mattress is a medical device in accordance to MDD 93 42 EEC According to statutory regulations made by the authorities regarding medical devices the manufacturer is required to report all accidents or incidents involving there products We would be very grateful for all information involving accidents or incidents relating to our products by reporting them immediately to us here at Care of Sweden The system has been tested and approved according to the following standards BS 7177 Medium hazard BS EN 597 1 BS EN 597 2 BS 6807 EN ISO 12182 EN ISO 14971 EN ISO 10993 EN 14126 1 2 Intended use CuroCell AREA C5 is a replacement mattress that can be used in a range of health care environments to prevent pressure ulcers as well as treatment up to and including category 3 The recommended user weight is 0 230 kg For the Evac function the maximum use
6. is ready to be used 3 2 Hand check Hand check is used to ensure that the function of the mattress is correct This should be done regularly Open the cover and insert your hand between the air cells directly underneath the user s pelvic region use a vertical hand There should be a clearance of 2 3 fingers between mattress base and the patient If not you need to check cells and tubing If the problem is not resolved please contact Care of Sweden or your local dealer 4 Cleaning and reconditioning It is important to follow the instructions below before using the product for a different user Consult the hygiene responsible or the supplier for help and instructions when unsure NOTE Check the hygiene cover each time the product is cleaned If damaged it must be replaced or repaired 4 1 Covers MATTRESS COVER Covers can be wiped off with a mild cleaning solution for this purpose such as alcohol with or without tensides Isopropanol 70 oxidating solutions or chlorine max 1 Excrements and blood spots must be removed immediately with cold water Carefully follow local instructions and usage instructions for the cleaner Te Q Ul Bx R Multi layer covers should be divided before washing Wash with similar colours Chlorine and phenol based cleaners could have a negative impact on the PU surface lt 19 and should be avoided If chlorine is used we recommend a mixture of max 1 INNER COVER 87 Q ll Bet
7. amage stemming from negligence or improper handling care 10 2 Service and repairs Service and maintenance must always be performed by Care of Sweden or one of its authorised technicians Only use spare parts that have been approved by Care of Sweden Use of non approved spare parts invalidates the warranty A warranty claim must be submitted to Care of Sweden before the product is returned Please contact Care of Sweden or your local dealer if you have questions regarding warranty and service 10 3 Life expectance This product s expected life is estimated to be 5 years 11 Other information 11 1 Disassembling and recycling A used CuroCell mattress must be taken to a recycling centre and sorted as combustible waste For more information contact Care of Sweden or your local dealer 13 12 Own notes 14 15 anil Manufactured by Care of sweden Supporting Life Contact Phone 46 771106600 Fax 46 325 12840 Email info careofsweden se Internet www careofsweden com Address Care of Sweden AB P O Box 146 SE 514 23 Tranemo SWEDEN Visit address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Cargo address Byns vag 4A SE 514 33 Tranemo SWEDEN Supplied by Care of Sweden and CuroCell are trademarks of Care of Sweden AB Care of Sweden AB 2015 16
8. ith the zipper closed Always store at room temperature in a dry area Make sure the mattress is stored where it will not be exposed to thrusts hits or other things that can damage it Avoid direct exposure of sunlight If the mattress is to be stored more than 3 months we recommend it is stored on a flat surface not folded or rolled up 6 Troubleshooting Problem Solution The patient is bottoming out Open covers and check cells and tubing Check again through Hand check see chapter 3 2 If your questions are not answered by information above please contact Care of Sweden or your local dealer 7 Technical description 7 1 Technical specification MATTRESS SPECIFICATION CuroCell AREA Zone C5 Dimension WxLxH 80 85 90 105 120 x 200 210 220 x 18 cm 16 kg 90x200x18 cm NOTE The manufacturer retains the right to modify the product specification at any time WARNING Follow the operations and maintenance instructions carefully in order to prevent bodily injuries as well as damages to the product or other equipment BHEHHEHEHEHE EEE et eae ee 7 2 Labelling The mattress is labelled with product name production date article number size care and wash instructions EAN bar code as well as space for own labelling The product also displays which side is up down and head foot 10 E m TI Article No Read the user manual pa Not in domestic refuse follow recycling instructions av2a
9. ity The system uses patient weight and movements to distribute the internal air reservoir amongst the cells in order to always maintain low surface pressure The CuroCell AREA Zone C5 are produced in high quality materials for excellent function and durability The mattress have a sloped heel section for protection of heels Available sizes are width length and height 80 85 90 105 120 x 200 210 x 18 cm For request of other sizes please contact Care of Sweden or your local dealer 2 1 Description cover CuroCell AREA Zone C5 is delivered with a hygiene cover It is easy to handle and maintain and manage high standards of cleaning and hygiene The cover is vapour permeable which reduces risk of skin maceration It is a two part cover with welded seems top part and a protected zipper Bottom part have Evac function which means functional handles for evacuation moving and transport An inner cover protects foam and cells 2 2 Description mattress CuroCell AREA Zone C5 1 Label Head end 2 Foam core 3 Tubing system 4 Air cells 5 Foam top part 3 Instruction for use 3 1 Unpacking the mattress The mattress is packed in a box 1 Start with making sure that the package is not damaged When opening the box and any other protective material avoid using a knife since this could damage the mattress and cover 2 Put the mattress on the bed frame and correct the cover if necessary 3 After a few minutes the product
10. m 120x210 cm 120x220 cm Description Size Evac cover bottom part Art No 461 080200 461 080210 461 080220 461 085200 461 085210 461 085220 461 090200 461 090210 461 090220 461 105200 461 105210 461 105220 461 120200 461 120210 461 120220 Air cell AREA 1 pcs 63x15x12 cm 9 Accessories 9 1 Accessories Inner Cover AREA Art No Size CC 928250 80x200 cm CC 928251 80x210 cm CC 958249 80x220 cm CC 928252 85x200 cm CC 928253 85x210 cm CC 928561 85x220 cm CC 928254 90x200 cm CC 928255 90x210 cm CC 928265 90x220 cm CC 928256 105x200 cm CC 928257 105x210 cm CC 958271 105x220 cm CC 928258 120x200 cm CC 928259 120x210 cm CC 928292 120x220 cm 12 Size 80x200 cm 80x210 cm 80x220 cm 85x200 cm 85x210 cm 85x220 cm 90x200 cm 90x210 cm 90x220 cm 105x200 cm 105x210 cm 105x220 cm 120x200 cm 120x210 cm 120x220 cm Sturdy transport and storage bag Art No Width 58 900905 105 120 cm 58 900906 extra high 80 90 cm 58 900911 extra high 105 120 cm 9 2 Other accessories To ensure the best level of comfort we recommend use of accessories from Care of Sweden since our products are designed to work well together Please contact Care of Sweden or your local dealer for accessories or more information on our products 10 Warranty 10 1 Scope This CuroCell system is covered by a 5 year warranty for manufacturing defects The warranty does not apply to normal wear and tear or product impairment or d
11. on plan you will find examples which can be applied and put into practice when using our products Mattress guide This practical guide gives you as a care giver help in choosing the correct mattress from the Care of Swedens range CuroCell AREA C5 is a mattress in function group B This information can be found on our website www careofsweden com or you can order a copy from our Customer services by sending your details to info careofsweden se 1 4 Evacuation instructions Evac is a mattress cover with a built in function for evacuation of bed bound users In case of fire or other emergency there is no time to think about what to do next Therefore it is very important that the safety equipment as well as the evacuation procedures are well planned and known in advance The Evac cover is equipped with three handles on the head and foot end On the sides there are handles with Velcro straps These straps are to be used to fixate the user to the mattress before commencing the evacuation The straps are folded in the protective pockets on the side of the mattress with the ends sticking out to ensure that they are easy to pull out PPPS WARNING Person to perform an evacuation needs to have the necessary training Always check the equipment cover and mattress before commencing to make sure an evacuation can be carried out safely It is the user s responsibility to ensure that it is safe to use for evacuation Evacuation instruc
12. r weight is 130 kg ea We recommend that repositioning of the user is performed regularly The time interval must be assessed by the responsible personnel depending on user s status diagnostic and general condition The mattress must always be cleaned between patients NOTE e When used together with positioning pillows read the pillow user manual carefully for correct positioning of the patient e f you are using this product with an evacuation sheet it is the user s responsibility to ensure that it is safe to use for evacuation e Be careful when using bed rails or other protection on the bed so that the mattress does not become crushed or damaged e The mattress must not be lifted with a person lying on it or used for any other type of transport other than a possible evacuation using an evacuation sheet This mattress is unsuitable for use during x ray examinations because of the risk of blurred images or artefacts that may lead to diagnostic errors 1 National Pressure Ulcer Advisory Panel European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance Prevention and Treatment of Pressure Ulcers Quick Reference Guide Emily Haesler Ed Cambridge Media Osborne Park Western Australia 2014 1 3 Other information Action plan Pressure ulcers To achieve the best possible result for this product it is recommended that a well planned and well structured working environment be used In our guideline Acti
13. tions Down from the bed e Inform the patient about what will happen e Lower and lock the bed in position e Disconnect the tubes from the pump e Pull out and fasten the Velcro straps e Use the outer handles at the foot end of the mattress and turn the mattress out from the bed e Slowly pull the patient down on to the floor On an even surface e Pull on the outer handles at the foot end of the mattress e Working position should be a little bit leaning back Down the stairs e Walk backwards until the main part of the mattress has slide pass the top stair e Turn the back to the patient and look in the moving direction e Hold one hand on the stair handle and pull with the other hand on the middle handle of the mattress e Walk down the stairs It is important to maintain speed without running Training practise To bear in mind when training Pulling down from the bed e The patient in the bed should not be at the very top of the mattress There could be a risk of hitting the head in the bed when pulling down Pulling in the stairs e Start with pulling an empty mattress down the stairs in order to practice the technique e When training with a person on the mattress a string or rope can be fasten in the handles at the head end Another person can then walk behind the mattress and help out if problems should occur e It is advisable to practice in the same stairs where an evacuation can be necessary