Home

OWNER`S MANUAL

image

Contents

1. condition on both sensors less than 10 F or greater than 180 F will result in the error code Automatic restart is 2 minutes after the error is corrected A Inlet water temperature sensor is reporting a temperature in excess of 104 F Normal operation resumes 2 minutes after inlet water temperature sensor reports temperatures of 104 F or less This error functions in both normal and remote thermostat modes or B Inlet water temperature sensor is reporting a temperature change at a rate faster than 6 F in 60 seconds indicating a potentially damaging low water flow conditon Normal operation resumes when temperatures stabilize If this condi tion is detected 3 times the heater will lock out until the electrical power is cycled off and back on If one of the keypad buttons is closed or pressed for more than 30 s the error code will be displayed but the control will continue to function The error code will be cleared when the condition is corrected If the control exceeds the maximum number of ignition retries or recycles the heater will shut down and go into lockout Automatic reset is 60 minutes If communication between the ignition board and the display board is not estab lished within 3 s of power up an error will be displayed After communication is established if it is lost for 30 s the error will be displayed The error code will be cleared upon a valid data exchange between boards If the limit string opens the hea
2. A nnanet 12 Fahrenheit versus Celle areas 12 LL QUES PS oia dic 12 Sping Start Up nadia nains 12 EMO COUE Sioa inaenecioiadandienee 13 A A 15 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5400 www haywardpool com SAFETY INFORMATION Basic safety precautions should always be followed including the following Failure to follow instructions can cause severe injury and or death This is the safety alert symbol When you see this symbol on your equipment or in this manual look for one of the following signal words and be alert to the potential for personal injury WARNING warns about hazards that could cause serious personal injury death or major property dam age and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or prop erty damage and if ignored presents a potential hazard It can also make consumers aware of actions that are unpredictable and unsafe gt gt gt ATTENTION indicates special instructions that are important but not related to hazards READ AND FOLLOW ALL INSTRUCTIONS IN THIS OWNER S MANUAL AND ON EQUIPMENT IMPORTANT SAFETY INSTRUCTIONS Before installing or servicing this electrical equipment turn power supply OFF KEEP SAFETY LABELS IN GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED A WARNING To reduce risk
3. du plancher parce que les gaz plus lourds que l air se concentrent au niveau du plancher QUE FAIRE EN PR SENCE D ODEURS DE GAZ e Ne pas essayer d allumer l appereil e Ne pas toucher un commutateur lectrique Ne pas utiliser le t l phone dans la maison e Appeler imm diatement fournisseur de gaz chez un voisin Suivre les instructions du fournisseur de gaz e Si le fournisseur ne peut pas tre atteint appeler le service des incendies Utiliser uniquement les mains pour actionner les boutons de commande du gaz Ne jamais utiliser d outils Si le bouton ne s enfonce pas ou ne se tourne pas la main ne pas essayer de le r parer Appeler un technicien qualifi L utilisation de la force ou une tentative de r paration pourrait causer un incendie ou une explosion Ne pas utiliser cet appareil si une des composantes a t immerg e dans l eau Appeler imm diatement un technicien qualifi pour v rifier l appareil et remplacer toute composante du syst me de commande ou de gaz qui aurait t immerg e dans l eau Sile syst me surchauffait ou si le gazrefusait de se fermer placer le robinet d arr t manuel de gaz de l appareil en position FERM OFF OPERATING INSTRUCTIONS 1 STOP Read the safety information on this label 2 Change the MODE on the control panel to STANDBY 3 Remove the heater s front access panel 4 This appliance is equipped with an ignition d
4. name a few Improper chem istry balance and mineral content can cause scaling and deposits to form on pool walls in the filtration system in the heat exchanger tubes and additionally can promote corrosive action to all metals in the water path Chang ing spa water regularly and maintaining the correct chemical balance in your pool spa will keep the pool spa safe and sanitary and will help protect the heat exchanger Use a 4 way pool spa water test kit to check your water frequently at least weekly Use the following guidelines to help protect your heater s heat exchanger Recommended Effect of Low Levels Effect of High Levels Level 1 3 MEX hazy water algea growth swimmer irritation bleaching of clothes hair Bromine 2 4 2 4pm bacteria causing infections corrosive to heat exchanger corrosive to heat exchanger cloudy water scaling of heat exchanger 7 4 7 6 E ates a swimmer irritation reduced sanitizer effectiveness ne corrosive to heat exchanger Total Alkalinity 80 120 ppm large fluctuations in pH scaling of heat exchanger Calcium Hardness 200 400 ppm corrosive to heat exchanger scaling of heat exchanger 2700 3400 ppm poor salt chlorinator performance corrosive to heat exchanger 3 SKIMMER CHLORINATION Placing chlorine or bromine tablets directly into the skimmer may result in high chemical concentrations flowing through the heater DO NOT place chlorine or bromine tablets in the skimmer USE ONLY HAYWARD
5. of pump components Strainer cover must be properly secured to pump housing with strainer cover lock ring Before servicing NN pool and spa circulation system manual air relief valve must be in open position Do gt not operate pool and spa circulation system if a system component is not assembled Le properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter upper body WARNING Never operate or test the circulation system at more than 40 PSI A WARNING Fire and burn hazard Motors operate at high temperatures and if they are not properly isolated from any flammable structures or foreign debris they can cause fires which may cause severe personal injury or death It is also necessary to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk of burns A WARNING Failure to install according to defined instructions may result in severe personal injury or death USE ONLY HAYWARD GENUINE REPLACEMENT PARTS AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5 400 www haywardpool com WARNING The following Safety Rules for Hot Tubs recommended by the U S Consumer Product Safety Commission should be observed when using the spa 1 Spa or hot tub water temperatures should never exceed 104 F 40 C A temperature of 100 F 38 C is considered safe f
6. such leakage can cause damage MANUFACTURER IS NOT RESPON SIBLE OR LIABLE FOR ANY COSTS INCURRED BY SUCH DAMAGE IN NO CASE ARE WE TO BE HELD LIABLE FOR DAMAGE TO SURROUNDING AREA OR PROPERTY CAUSED BY LEAKAGE OR MALFUNCTION HOW TO CLAIM UNDER THIS WARRANTY The original owner upon discovering the defect must present the attached completed warranty claim card with proof of purchase either to the dealer or notify the Company in writing at either address HAYWARD POOL PRODUCTS INC 620 DIVISION ST ELIZABETH NJ 07207 OR HAYWARD POOL PRODUCTS INC 2875 POMONA BOULEVARD POMONA CA 91768 Upon receipt of such notification we shall decide whether to repair such parts or replace any pool heater reserving at all times the right to inspect in order to verify any claimed defect We also reserve the right to have our representatives make any inspections repairs or to furnish replacements This warranty is intended as a legally binding obligation of the Company enforceable in the courts This warranty may give you spe cific legal rights which may vary from state to state LIMITATION ON LIABILITY All intended representations have been expressly set forth in this document This warranty may not be extended by oral or any other additional representations written sales information drawings or other mal function is strictly limited to repair or replacement of the defective heater or part as provided herein and the Company is not resp
7. switch closes If the blower prover switch opens unexpectedly during operation the control will shut down and attempt to re light If the switch does not close after the blower starts the control will go into lockout with the blower running Automatic reset is immediate after error is corrected If the blower prover switch opens during the postpurge cycle heater is not fir ing the control will display the error code The post purge cycle will be com pleted once the blower prover switch closes If the blower prover switch is closed before blower start up the control will not start the blower Automatic reset is immediate when the switch opens USE ONLY HAYWARD GENUINE REPLACEMENT PARTS HAYWARD pool Products A Hayward Industries Inc Company Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com Figure 4 ERROR CODES continued Igniter open error Thermistor error Water Temperature Sensing Error HS Keypad button stuck closed error Ignition failure error Communication error Limit string open error EEPROM ERROR HAYWARD pool Products A Hayward Industries Inc Company If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout Auto matic restart 2 min after error is corrected An excessive temperature difference between the two thermistors 5 F or more or an out of bounds
8. the internal temperature of the body reaches a level several degrees above normal body temperature of 98 6 F 37 C The symptoms of Hyperthermia include drowsi ness lethargy dizziness fainting and an increase in the internal temperature of the body The effects of Hyperthermia include Unawareness of impending danger Failure to perceive heat Failure to recognize the need to leave the spa Physical inability to exit the spa Fetal damage in pregnant women Unconsciousness resulting in danger of drowning HAS DR DEFINITIONS Suction Outlet The term Suction Outlet is a fitting fitting assembly cover grate and related compo nents that provide a means for water to exit the pool and into the pump circulating system Inches of Mercury in Hg A unit for measuring pressure below atmospheric suction or vacuum 1 0 inch Hg 491 PSI Main Drain See Suction Outlet PSI An abbreviation for pounds per square inch USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5400 www haywardpool com SECTION I GENERAL INFORMATION INTRODUCTION This manual contains instructions for operation and the safe use of the swimming pool spa hot tub heat ers Hayward strongly recommends that the owner read the manual before using the swimming pool spa hot tub heater If after reviewing the manual any questio
9. GENUINE REPLACEMENT PARTS El A AYWARD P ol Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5400 www haywardpool com 4 CHLORINATOR INSTALLATION Chlorinators must be installed downstream of the heater and a check valve must be installed between the heater and chlorinator to prevent high chemical concentrations from back flowing into the heater Make sure your piping arrangement meets the chlorinator installation requirements shown in the installation manual on page 26 5 BYPASS Until water chemistry is properly balanced and if your piping has a bypass valve installed for the heater open the bypass so that corrosive and potentially damaging water will not flow through the heater and there fore the heat exchanger Close the bypass valve once the water is properly balanced Failure to close the bypass valve when attempting to operate the heater will result in extensive damage to the heat exchanger Ensure water flow through the heater is restored before operating the heater A bypass feature is also advanta geous for service needs and for the ability to remove the heater from the water path when not heating Refer to page 25 in the installation manual for further information HEATER OPERATION Full lighting and shutdown instructions are included on the lighting amp operating instructions label affixed to the inside of the front access panel See Figure for the location of this label and th
10. HAYWARD POOL AND SPA HOT TUB HEATERS H150FD H200FD H250FD H300FD H350FD amp H400FD MODELS OWNER S MANUAL FOR YOUR SAFETY AR WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage injury or death Do not store or use gasoline or other flam mable vapors or liquids in the vicinity of this or any other appliance vat TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY This product must be installed and serviced by authorized personnel qualified in pool spa heater installation Improper installation and or operation can create carbon monoxide gas and flue gases that can cause serious injury property damage or death U S PATENT NOS 6 321 833 amp 7 971 603 1301640701 REVE 1211 CONTENTS Y A 3 Section General information naar 7 Section Il Consumer Operation amp Maintenance oooccccccccnnoncccnnnonnnnnnnnnnns 8 Maintaining proper water chemistry 8 Lighting amp Operating instructions label 10 Temperature AUS Meis 11 Temperature DOG KOU iii
11. L mode or adjusting the temperature setting it is normal for the heater to delay up to 10 seconds before the heater starts operating This delay is an internal self test of the heater On occasion the numeric display may show a diagnostic error code refer to list of diagnostic error codes in Figure 4 Pressing the MODE button to cycle to STANDBY and back to SPA or POOL will clear a diagnostic error code When clearing a diagnostic error code this way it is normal for the heater to delay up to 5 seconds before resuming normal operation assuming the diagnostic error code does not re appear Figure 3 User interface keypad Numeric Display HAYWARD Mar Poot Tere Lire b Pre Indicator Lights Buttons USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5 400 www haywardpool com TEMPERATURE LOCK OUT The digital thermostat in this pool heater allows the user to lock the maximum temperature setting allowed This feature is useful for preventing unauthorized users from manually adjusting the temperature settings higher than desired On a new heater the maximum allowed temperature lock settings are initially set at the factory to 90 F for POOL mode and 104 F for SPA mode To adjust these settings use the following procedure 1 Use the MODE button to put the heater in STANDBY mode 2 Press and hold both the UP and DOWN buttons a
12. areas or on the backrest for such seating areas e The maximum system flow rate shall not exceed the flow rating of any listed per current revision of ASME ANSI A112 19 8 suction outlet cover installed e Never use the Pool or Spa if any suction outlet component is damaged broken cracked missing or not securely attached e Replace damaged broken cracked missing or not securely attached suction outlet components im mediately e Install two or more suction outlets per pump in accordance with latest APSP formally NSPI Stan dards and CPSC guidelines Follow all applicable National State and Local codes USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD Poo Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5400 www haywardpool com A WARNING Failure to remove pressure test plugs and or plugs used in winterization of the pool spa from the suction outlets can result in an increase potential for suction entrapment as described above A WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material can result in an increase potential for suction entrapment as described above A WARNING Suction outlet components have a finite life the cover grate should be inspected fre quently and replaced at least every ten years or if found to be damaged broken cracked missing or not securely attached A WARNING All sucti
13. d nickel Cupronickel materials The premium materials and the exacting processes used in the manufacture of the heat exchanger is state of the art in pool heater design and manufacture Yet it remains vital that the heat ex changer be protected from damaging or corrosive chemicals insufficient water flow or improperly balanced water chemistry Heat exchanger damage or failure resulting from improper flow improperly balanced pool water or the improper addition of sanitizers into the water is NOT covered under the terms of your warranty The following factors are critical to heat exchanger protection Follow these guidelines to help prevent pre mature damage or failure to your heater and heat exchanger 1 WATER FLOW THROUGH HEATER Water must be flowing through the heater at the minimum rated flow rate during operation Check that the pump is operating and the system is filled with water and purged of all air prior to starting the heater The minimum rated flow rates are listed in the installation manual on page 25 Some installations may require an adjustment to the water pressure switch for proper low flow protection Test your system and if necessary adjust the water pressure switch as described in the installation manual on page 34 2 POOL SPA WATER CHEMISTRY The chemistry balance and mineral content of swimming pool water changes daily due to the addition of pool and sanitizing chemicals bather loads rain runoff and the amount of sun to
14. e keypad See Figure 2 for the label Figure 1 Keypad and label locations User Interface Keypad er A y Front Access Panel A WARNING If you smell gas in the appliance area or near the floor PROPANE IS HEAVIER THAN AIR AND HENCE SETTLES ON THE FLOOR stop and follow the instructions on the front cover of this manual Since propane can accumulate in con fined areas extra care should be taken when lighting propane heaters A ATTENTION Do not use the heater below 40 F 4 C temperature without adequate temperature protection A WARNING Do not ingest alcohol or drugs during use or prior to using pool spa or hot tub Ingestion of such intoxicants can cause drowsiness which can lead to unconsciousness and subsequently result in drowning USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5 400 www haywardpool com Figure 2 Lighting amp Operating Instructions label FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance does not have a pilot It is equipped with an ignition device which automatically lights the burners Do not try to light the burners by hand BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor becau
15. eezing or for freeze protection Care must be taken to avoid freeze up in the heater When it is used during freezing weather the pump must run continuously The heater is not warranted against freeze ups In regions where freezing temperatures are encountered all water must be drained from the heater when it is out of service to prevent damage to the heater and piping Drain ing the heat exchanger is recommended as part of the season s shutdown procedures SPRING START UP CONSULT A PROFESSIONAL 1 Inspect and clean the heater being sure the heater is free of leaves and debris prior to startup 2 Be sure inlet and outlet piping are properly attached to the heater and the drain valve is closed 3 Turn the filtration system pump ON and allow the system to run long enough to purge all the air from the lines 4 Turn the gas supply to the heater ON 5 Set the temperature control using the keypad to POOL or SPA and adjust the set point to the desired temperature setting 6 If operating difficulties are encountered contact a qualified service company for assistance ERROR CODES Figure 4 lists the error codes that may be displayed on the heater display board Contact a qualified service company for assistance Figure 4 ERROR CODES Internal fault power up error Gas valve sensed as ON error Gas valve sensed as OFF error Data retrieval error Flame present with gas valve OFF erro
16. er y O A WARNING To reduce the risk of electric shock replace damaged wiring immediately Locate conduit to prevent abuse from lawn mowers hedge trimmers and other equipment A WARNING Failure to bond to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock the electrician must comply with installation in structions and must bond the heater accordingly In addition the licensed electrician must also conform to local electrical codes for bonding requirements USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5 400 www haywardpool com NOTES TO THE ELECTRICIAN Use a solid copper conductor size 8 or larger Run a continuous wire from external bonding lug to rein forcing rod or mesh Connect a No 8 AWG solid copper bonding wire to the grounding lug provided on the heater and to all metal parts of swimming pool or spa and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool or spa IMPORTANT Reference NEC codes for all wiring standards including but not limited to grounding bonding and other general wiring procedures warninc Suction Entrapment Hazard Suction in suction outlets and or suction outlet covers which are damaged broken cracked missing or unsecured can cause
17. evice which auto matically lights the burner Do not try to light the burners by hand 5 Turn gas control knob clockwise TA to OFF GAS CONTROL KOI KNOB SHOWN IN OFF 365 POSITION ae 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information on this label If you don t smell gas go to the next step 7 Turn gas control knob counterclockwise to ON 8 Replace the heater s front access panel Set the MODE on the control panel to SPA or POOL Set the set point temper ature on the control panel to the desired setting If the appliance does not operate repeat steps 2 thru 10 If the appliance still does not operate follow instructions TO TURN OFF GAS TO APPLIANCE and call your service technician or gas supplier TO TURN OFF GAS TO APPLIANCE 1 Change the MODE on the control panel to STANDBY 2 Remove the heater s front access panel 3 Turn the gas control knob clockwise lt gt to OFF 4 Replace the heater s front access panel INSTRUCTIONS D ALLUMAGE STOP Lire les consignes de s curit sur cette tiquette 2 Changer le MODE du tableau de commande STANDBY 7 Retirer le panneau d acc s avant de l appareil de chauffage Cet appareil est pourvu d un dispositif d allumage qui allume automatiquement les br leurs Ne pas
18. l other implied warranties that may arise from course of dealing or usage of trade imposed on the sale of this heater under laws of the state are limited in duration to the term of one 1 year for all users There are no warranties which extend beyond the description on the face hereof We shall not in any event be held liable for any special indirect or conse quential damages EXPENSE OF DELIVERY AND INSTALLATION Each pool heater or replacement part to be furnished under this warranty shall be furnished at our nearest distribution center We shall not pay nor be responsible for shipping or delivery charges to the place of instal lation nor for labor charges or other costs of removal or installation Every defective heater or part replaced under this warranty shall become our property and as such must be returned to our distribution center with transportation charges paid by the user Any replacement pool heater furnished under this warranty shall re main in warranty only for the unexpired portion of this warranty CONDITIONS AND EXCEPTIONS This warranty applies only to the pool spa at its original place of installation and only for the original owner It does not apply if the pool heater is installed in violation of any applicable code or ordinance or is not installed operated and maintained in accordance with our instructions or is misused damaged by ac cident weather act of God freezing water void and or excess pressure altered
19. ns remain unanswered contact the factory or local representative LIMITED WARRANTY SUMMARY We warrant the pool spa hot tub heater to be free from defects in materials and workmanship and we will within one year from date of installation for all users for the original purchaser repair or at our option replace without charge any defective part We further warrant that if the heat exchanger or exchanger headers water containing section leak within one year from date of such installation for all users due to defects in materials and workmanship we will provide a replacement part Cost of freight installation fuel and service labor after one year is at user s expense For full details of warranty agreement see warranty certificate included in this manual A ATTENTION If the pool spa hot tub heater is damaged or destroyed by improper maintenance exces sive water hardness incorrect water chemistry or freezing it is not covered under the manufacturer s warranty USE ONLY HAYWARD GENUINE REPLACEMENT PARTS AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5 400 www haywardpool com g SECTION II CONSUMER OPERATION amp MAINTENANCE MAINTAINING PROPER WATER CHEMISTRY Failure to Maintain Proper Water Chemistry May Cause A WARNING Premature Heat Exchanger Damage or Failure The heat exchanger in your Hayward pool heater is made from the highest quality of copper an
20. of injury do not permit children to use or climb on the heater pumps or filters Closely supervise children at all times Components such as the filtration system pumps and heaters must be positioned to prevent children from using them as a means of access to the pool CAUTION This heater is intended for use on permanently installed swimming pools and may also be used with spas Do NOT use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly recommended to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circulation of air for cooling Do not install in a damp or non ventilated location A WARNING It is required that licensed electricians do all electrical wiring Risk of Electric Shock Hazardous voltage can shock burn cause death or serious property damage To reduce the risk of electric shock do NOT use an extension cord to connect unit to electric supply Provide a properly located outlet All electrical wiring MUST be in conformance with applicable local and national codes and regulations Before work ing on this unit turn off power supply to the heat
21. on and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage All drains and suction outlets MUST have properly installed covers securely attached using the screws supplied with the cov ers If screws are lost order replacement parts from your supplier A WARNING Hazardous Pressure Pool and spa water circulation systems operate under hazardous pressure during start up normal operation and after pump shut off Stand clear of circulation system equipment during start up Failure to follow safety y and operation instructions could result in violent separation of the pump housing WA and cover due to pressure in the system which could cause property damage severe personal injury or death Before servicing pool and spa water circulation system all system and pump controls must be in off position and filter manual air relief valve must be in open position Before starting system pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while system pump is running Before starting system pump fully open filter manual air relief valve Do not close filter manual air relief valve until a steady stream of water not air or air and water is discharged A WARNING Separation Hazard Failure to follow safety and operation instruc tions could result in violent separation
22. onsible hereunder for incidental or consequential or incidental costs or damages The company neither assumes nor authorizes any person or firm to assume for us any further liability or obligation in connection with the sale installation use maintenance or existence of the heater SAFETY WARNING Pool heaters are heat producing appliances and to avoid damage or injury in the event of pos sible overheating of the outer jacket 1 no materials should be stored against the jacket and 2 care should be taken to avoid unnecessary contact especially by children with the jacket When lighting a gas heater the lighting instructions must be followed exactly to prevent flashback of excess gas in the heater Electronic ignition heaters and electric heaters must have the power shut off when making adjustments to servicing or coming into contact with the heater UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE MATERI ALS SUCH AS GASOLINE OR PAINT THINNERS BE USED OR STORED IN THE VICINITY OF THE HEATER OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE HEATER For your comfort enjoyment and safety please read the enclosed operating instructions carefully USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5400 www haywardpool com
23. or a healthy adult Special caution is suggested for young children Pro longed immersion in hot water can induce hyperthermia 2 Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subsequently result in drowning 3 Pregnant women beware Soaking in water above 100 F 38 C can cause fetal damage during the first three months of pregnancy resulting in the birth of a brain damaged or deformed child Preg nant women should adhere to the 100 F 38 C maximum rule 4 Before entering the spa or hot tub users should check the water temperature with an accurate ther mometer spa or hot tub thermostats may err in regulating water temperatures by as much as 4 F 2 2 C 5 Persons taking medications which induce drowsiness such as tranquilizers antihistamines or anti coagulants should not use spas or hot tubs 6 Ifthe pool spa is used for therapy it should be done with the advice of a physician Always stir pool spa water before entering the pool spa to mix in any hot surface layer of water that might exceed healthful temperature limits and cause injury Do not tamper with controls because scalding can result if safety controls are not in proper working order 7 Persons with a medical history of heart disease circulatory problems diabetes or blood pressure problems should obtain a physicians advice before using spas or hot tubs 8 Hyperthermia occurs when
24. or disconnected It does not apply with respect to 1 A heater not equipped with Certified C S A limit controls or equivalent pressure relief valve 2 A heater operated with settings in excess of and or with fuel not conforming to those shown on rat ing plate A heater on which the serial numbers have been altered defaced or removed Leaks arising from defective installation Production of noise odors or discolored rusty etc water Leakage substantially contributed to by sediment lime precipitate and or higher than normal dis solved solids pH above 7 8 in the tank copper tubes or water ways 7 Leakage caused substantially contributed to by corrosive elements in the atmosphere such as the storage of chlorine or other chemicals 8 Leakage caused substantially or contributed to by corrosive pool water in an acid condition pH below 7 2 9 Damage caused substantially or contributed to by an external source of energy 10 A pool spa heater is a water containing device Leakage of water from this device can be expected at some time due to malfunction or the limitations of the service life of various components OS 1 WwW CONTINUED ON PAGE 16 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS AYWARD pool Products Pomona CA Clemmons NC Nashville TN A Hayward Industries Inc Company Tel 908 35 1 5 400 www haywardpool com HAYWARD POOL HEATER CERTIFICATE OF LIMITED WARRANTY CONTINUED Do not install this product where
25. r Electrical supply wiring error Blower vacuum switch open error Blower vacuum switch open when expected closed error Blower vacuum switch open during post purge error HF PF AO AO AO AC Blower vacuum switch closed when expected open error On initial trial for ignition Automatic reset is immediate once the gas valve relay check results are acceptable If valve is open when it should be closed the heater will shut down and go into lockout Blower will operate until error condition is corrected Automatic restart 2 minutes after error is corrected If valve is closed but flame is sensed the blower will run for 5 s then start a new ignition sequence If error occurs 10 times during a call for heat the control will go into lockout Automatic reset is 60 minutes If control input data is corrupted the heater will shut down and go into lockout If flame is sensed with the gas valve off the control will go into lockout The blower will run until error condition is corrected When corrected control will run blower for 5 s then automatically restart after 2 minutes This code will display if 120V polarity is reversed low voltage is detected or if the ground path is not sufficient Reset is immediate after error is corrected If the blower prover switch does not close after the blower starts the control will stop the ignition trial go into lockout The blower will continue to run Automatic reset is immediate after the
26. se some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliances Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use oniy your hand to turn the gas control knob Never use tools If the knob will not turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Should over heating occur or the gas supply fails to shut off turn off manual gas valve to the appliance POUR VOTRE SECURITE LIRE AVANT L ALLUMAGE MISE EN GARDE Si vous ne suivez pas exactement ces instructions un incendie ou une explosion pourrait survenir et causer des dommages a la propri t des blessures corporelles ou la perte de la vie Cet appareil n a pas de pilote Un m canisme d allumage automatique pour les br leurs N essayer pas d allumer les br leurs la main AVANT L ALLUMAGE sentir tout autour de l appareil pour d celer d ventuelles odeurs de gaz S assurer de sentir pr s
27. severe injury and or death due to the fol lowing entrapment hazards Hair Entrapment Hair can become entangled in suction outlets Limb Entrapment A limb inserted into an opening of a suction outlet or suction outlet cover that is damaged broken cracked missing or not securely attached can result in a mechanical bind or swelling of the limb Body Suction Entrapment A differential pressure applied to a large portion of the body or limbs can result in an entrapment Evisceration Disembowelment A vacuum applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover which is damaged broken cracked missing or unsecured can result in evisceration disembowelment Mechanical Entrapment There is potential for jewelry swimsuit hair decorations finger toe or knuck le to be caught in an opening of a suction outlet or suction outlet cover resulting in mechanical entrap ment Awarninc To reduce the risk of entrapment hazards e When suction outlets are less than a 18 x 23 equivalent a minimum of two function ing suction outlets per pump must be installed Suction outlets in the same plane i e floor or wall must be installed a minimum of three feet 3 1 meter apart as mea sured from near point to near point e Dual suction outlets shall be placed in such locations and distances to avoid dual blockage by a user e Dual suction fittings shall not be located on seating
28. t the same time 3 After 3 seconds the thermostat enters maximum temperature lock adjustment mode 4 The SPA indicator light illuminates and the numeric display shows the current SPA mode maximum temperature lock setting Both the SPA indicator light and the numeric display flashes rapidly when in adjustment mode 5 Use the UP and DOWN buttons to set the desired maximum temperature lock setting When finished press the MODE button 6 The POOL indicator light illuminates and the numeric display shows the current POOL mode maximum temperature lock setting Both the POOL indicator light and the numeric display flashes rapidly when in adjustment mode 7 Use the UP and DOWN buttons to set the desired maximum temperature lock When finished press the MODE button 8 The heater will return to STANDBY mode FAHRENHEIT VERSUS CELSIUS The temperature can be displayed in Fahrenheit or Celsius TO change the display use the MODE button to place the heater in STANDBY Then press and hold the UP and MODE buttons until the display shows the F C selection Press the DOWN button to toggle between selections To accept the selection press the MODE button If the user does not act the selection will be automatically accepted after 60 seconds WINTERIZATION In moderate climates the heater can continue to operate during short term cold spells Do not use the heater to maintain the water temperature just above fr
29. tenter d allumer manuellement les br leurs 5 Tourner le bouton de commande du gaz en sens 7x horaire OFF ferm BOUTON DE COMMANDE KO DE GAZ MONTR 10 EN POSITION N FERM OFF SN 6 Attendre cing 5 minutes que tout gaz se dissipe Arr ter si l on sent alors une odeur de gaz Suivre B dans les consignes de s curit de cette tiquette Passer l tape suivante en l absence d odeur de gaz Tourner le bouton de commande du gaz en sens anti horaire ON OUVERT Arn Replacer le panneau d acc s avant de l appareil de chauffage R gler le MODE du tableau de commande SPA ou POOL tablir la valeur de r glage sur le tableau de commande la temp rature d sir e Si l appareil ne fonctionne pas r p terles tapes 2 10 Si l appareil refuse toujours de FERME fonctionner dissipe Suivre les instructions Pour tourner le gaz l appareil et appeler votre technicien de service ou votre fournisseur de gaz POUR FERMER LE GAZ SUR L APPAREIL Changer le MODE du tableau de commande STANDBY Retirer le panneau d acc s avant de l appareil de chauffage Tourner le bouton de commande du gaz en sens horaire a OFF ferm Replacer le panneau d acc s avant de l appareil de chauffage 1301623001 REV A USE ONLY HAYWARD GENUINE REPLACEMENT PARTS H AYWARD Po ol Products Pomona CA Clemmons NC Nashville TN A Ha
30. ter shuts down and goes into lockout Automatic restart is 2 minutes after the error condition is corrected and the limit string closes See below for more detail An error was detected in the ignition control circuit board USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Pomona CA Clemmons NC Nashville TN Tel 908 351 5400 www haywardpool com HAYWARD POOL HEATER CERTIFICATE OF LIMITED WARRANTY Limited heater warranty TERMS AND COVERAGE We warrant our pool heater to be free from defects in workmanship and materi als under normal use and service Pursuant to this warranty and subject to the Conditions and Exceptions indicated below 1 We will replace cost of freight installation cost of fuel and service labor at user s expense with the prevailing comparable model or at our option repair any pool spa heater that leaks under nor mal use and service within one year from the date of original installation for all users 2 In addition we will replace cost of freight installation cost of fuel and service labor at user s expense or at our option repair any part or parts of the pool spa heater which malfunctions under normal use and service within one year from the date of original installation for all users LIMITATION ON IMPLIED WARRANTIES WE ARE NOT LIABLE FOR ANY CONSEQUENTIAL DAMAGES FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY OF THIS PRODUCT Im plied warranties including the WARRANTY of MERCHANTABILITY and al
31. yward Industries Inc Company Tel 908 35 1 5400 www haywardpool com TEMPERATURE ADJUSTMENT This pool heater is equipped with a digital thermostat which allows the user to select the desired water temperature The heater will then function automatically to maintain the desired temperature The heater has 3 modes of operation 1 STANDBY in this mode the heater will not function to heat the water 2 SPA in this mode the heater will automatically function to maintain the water temperature setting for SPA mode 3 POOL in this mode the heater will automatically function to maintain the water temperature setting for POOL mode Use the MODE button to change modes The indicator lights will illuminate to show which mode the heater is currently in Each mode has its own temperature setting allowing the user to have 2 individual pre set temperature settings To adjust the temperature while in SPA or POOL mode use the UP and DOWN buttons The numeric display will flash to indicate the temperature setting is being displayed adjusted When the numeric display is not flashing the actual water temperature is being displayed The temperature settings for both SPA and POOL modes are initially set at the factory to 65 F The minimum allowed settings for SPA and POOL modes are both 65 F The maximum allowed settings for SPA and POOL modes are adjustable up to 104 F using the temperature lockout feature see next section After selecting SPA or POO