Home

USER MANUAL

image

Contents

1. 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3 Overview The TR 1YC and the TR 2YC are high performance video isolation transformers for s video Y C signals In many applications the connection between video sources and acceptors induces 50Hz or 60Hz ground loops with an undesirable effect such as hum bars and audio hum The TR 1YC and the TR 2YC provide complete isolation between the video source and receptor thus eliminating video hum ground loops and DC offsets which can degrade picture quality In the TR 1YC unit the luminance signal Y is transformer coupled while the band limited chrominance C signal is coupled via a capacitor with high voltage breakdown The unit is mainly intended to solve ground problems and DC offsets In the TR 2YC unit both the luminance Y signal and the chrominance C signal are transformer coupled to allow the broadband signal to pass with minimum deterioration Both the TR 1YC and TR 2YC units e Are designed to withstand very high potential differences on both channels between the input and output e Allow the user to select the ground link by dipswitches e Are housed in a Kramer TOOLS enclosure and require no power supply making them ideal for field applications To achieve the best performance e Connect only good quality connection cables thus avoiding interference deterioration in signal quality due to poor matching and elevated noise levels often associ
2. the video input 3 s VIDEO OUT 4p Connector Connects to the video output Your Isolation Transformers Figure 3 and Table 3 define the underside of the TR 1YC and TR 2YC FLOAT Y C output signal shield Input socket shield Output socket shield m Y C input signal shield Figure 3 The s Video Isolation Transformers Underside Table 3 Features and Functions of the s Video Isolation Transformers Underside Feature Function Output socket shield Set to GROUND to connect the output socket shield to the chassis Otherwise set to FLOAT Y C output signal shield Set to GROUND to connect the Y C output signal shield to the chassis Otherwise set to FLOAT Input socket shield Set to GROUND to connect the input socket shield to the chassis Otherwise set to FLOAT Y C input signal shield Set to GROUND to connect the Y C input signal shield to the chassis Otherwise set to FLOAT Figure 4 illustrates the dipswitch definitions Y C INPUT SIGNAL SHIELD Y C OUTPUT OUTPUT SOCKET SHIELD SIGNAL SHIELD SOCKET SHIELD Figure 4 Dipswitch Definitions KRAMER SIMPLE CREATIVE TECHNOLOGY Using the Isolation Transformer 5 5 1 Using the Isolation Transformer The Isolation Transformers are used for s Video signals There are no general rules as to how and where to connect the Isolation Transformers This depends on many factors which rela
3. Kramer Electronics Ltd ah KRAMER USER MANUAL Models TR 1YC s Video Isolation Transformer TR 2YC s Video Dual Isolation Transformers Contents Contents 1 Introduction 2 Getting Started 2 1 Quick Start Overview Your Isolation Transformers 5 Using the Isolation Transformer 5 1 Connecting the Isolation Transformer 6 Technical Specifications Figures Figure 1 TR 1YC s Video Isolation Transformer Figure 2 TR 2YC s Video Dual Isolation Transformers Figure 3 The s Video Isolation Transformers Underside Figure 4 Dipswitch Definitions Figure 5 Connecting the TR 2YC s Video Dual Isolation Transformers Tables Table 1 Features and Functions of the TR 1 YC s Video Isolation Transformer Table 2 Features and Functions of the TR 2YC s Video Dual Isolation Transformers Table 3 Features and Functions of the s Video Isolation Transformers Underside Table 4 Technical Specifications of the TR 1 YC and TR 2YC O aN BW ONNMN OanDMNA Introduction 2 1 Introduction Welcome to Kramer Electronics since 1981 a world of unique creative and affordable solutions to the infinite range of problems that confront the video audio and presentation professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 500 plus different models now appear in 8 Groups which are clearly defined by function Congratulations on purchasing y
4. NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removal or installation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charg
5. Web site www kramerelectronics com E mail info kramerel com P N 2900 000240 REV 1
6. ance The same principles apply to the TR 1YC simply connect the unit anywhere between the source and acceptor as required 1 In most applications the ground is not connected 2 See above usually set by trial and error 7 Technical Specifications A s Video Player s Video Display Figure 5 Connecting the TR 2YC s Video Dual Isolation Transformers 6 Technical Specifications Table 4 Technical Specifications of the TR 1YC and TR 2YC INPUT j s Video on a 4p connector OUTPUT 1 s Video a 4p connector INSERTION LOSS 0 8dB BANDWIDTH 3aB 18MHz DIFF GAIN 0 12 DIFF PHASE 0 13 Deg K FACTOR 0 8 to 0 9 S N RATIO 77 7dB CONTROLS Dipswitches for grounding control VIDEO TILT 0 1 Pulse amp Bar VIDEO NON LINEARITY 0 1 COUPLING AC DIMENSIONS 12 1cm x 7 2cm x 3cm 4 77 x 2 85 x 1 2 W D H WEIGHT 0 34 kg 0 75lbs approx ACCESSORIES Mounting brackets Specifications are subject to change without notice KRAMER SIMPLE CREATIVE TECHNOLOGY Kramer Electronics hereafter Kramer warrants this product free from defects in material and workmanship under the following terms HOW LONG IS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHO IS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS
7. ated with low quality cables e Avoid interference from neighboring electrical and magnetic appliances that may adversely influence signal quality and position your Kramer Isolation Transformers away from moisture excessive sunlight and dust 1 May show as a dark or light horizontal bar which slowly scrolls up or down the screen 2 Differences in ground potential may result in ground loops 3 Your Isolation Transformers 4 Your Isolation Transformers Figure 1 and Table 1 define the TR 1YC s Video Isolation Transformer KRAMER TOOLS s Video Isolation Transformer s VIDEO IN s VIDEO OUT Figure 1 TR 1YC s Video Isolation Transformer Table 1 Features and Functions of the TR 1YC s Video Isolation Transformer Feature Function 1 Ground For use when connecting the unit to an external ground 2 s VIDEO IN 4p Connector Connects to the video input 3 s VIDEO OUT 4p Connector Connects to the video output KRAMER SIMPLE CREATIVE TECHNOLOGY Your Isolation Transformers Figure 2 and Table 2 define the TR 2YC s Video Dual Isolation Transformers s Video Dual Isolation Transformers TR 2YC s VIDEO IN s VIDEO OUT F Figure 2 TR 2YC s Video Dual Isolation Transformers Table 2 Features and Functions of the TR 2YC s Video Dual Isolation Transformers Feature Function 1 Ground For use when connecting the unit to an external ground 2 s VIDEO IN 4p Connector Connects to
8. es HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to
9. our Kramer TR 1YC s Video Isolation Transformer and or TR 2YC s Video Dual Isolation Transformers This product is ideal for e Broadcast and production video studios e Staging and fieldwork The package includes the following items e TR 1YC or TR 2YC e This user manual Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual Quick Start This quick start chart summarizes the basic setup and operation steps 1 GROUP 1 Distribution Amplifiers GROUP 2 Video and Audio Switchers Matrix Switchers and Controllers GROUP 3 Video Audio VGA XGA Processors GROUP 4 Interfaces and Sync Processors GROUP 5 Twisted Pair Interfaces GROUP 6 Accessories and Rack Adapters GROUP 7 Scan Converters and Scalers and GROUP 8 Cables and Connectors 2 Download up to date Kramer user manuals from our Web site at http www kramerelectronics com 1 Getting Started Step 1 Connect the Machines Connect the TR 2YC between the source 1 and the acceptor 2 s Video Player s Video Display Step 2 Set the Dipswitches FLOAT The grounding conditions are Y C output signal shield Input socket shield set according to the field Output socket shield rm Y C input signal shield conditions BEBE Check all the options to work out which option best suits GROUND your needs
10. place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION B Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment B Use the supplied DC power supply to feed power to the machine B Please use recommended interconnection cables to connect the machine to other components 9 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Safety Warning Disconnect the unit from the power supply before opening servicing Caution 001 EY i lt 4 G Toc jg Institute of Quality amp Control Q Cr d Quality Kramer Electronics Ltd
11. te to the setup of the studio improper grounding and so on The recommended method is to disconnect all the equipment and then connect together one piece at a time checking for hum as each piece of equipment is re connected When hum is detected an appropriate Isolation Transformer is connected at that point to break the ground loop The Isolation Transformers also provide different grounding combinations which are set via the dipswitches for optimum operation The grounding conditions usually are set by trial and error Check all the options to work out which one best suits your needs This section describes how to connect an Isolation Transformer and set the dipswitches for optimum performance see section 5 1 Connecting the Isolation Transformer When installing an Isolation Transformer you just connect it somewhere on the line between the source and the acceptor The particular example in Figure 5 shows how to connect the TR 2YC s Video Dual Isolation Transformers However this is not a specific recommendation as there are many different configuration options To connect the TR 2YC as shown in the example in Figure 5 do the following 1 Connect a video source for example an s Video player to the s VIDEO IN 4p connector 2 Connect the s VIDEO OUT 4p connector to a video acceptor for example an s Video display 3 Turn the power ON on the s Video source and acceptor 4 Set the dipswitches for optimum perform